diff --git a/MIBS/telco-systems/binox/PRVT-SYNC-ETHERNET-MIB b/MIBS/telco-systems/binox/PRVT-SYNC-ETHERNET-MIB new file mode 100644 index 0000000..5055a6d --- /dev/null +++ b/MIBS/telco-systems/binox/PRVT-SYNC-ETHERNET-MIB @@ -0,0 +1,624 @@ +-- ********************************************************************* +-- ** +-- ** BATM Advanced Communications. +-- ** +-- ********************************************************************* +-- ** Filename: PRVT-SYNC-ETHERNET-MIB.mib +-- ** Project: T-Metro Switches. +-- ** Purpose: Private MIB +-- ********************************************************************* +-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved. +-- WARNING: +-- +-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING: +-- +-- This file is the property of BATM Advanced Communications and contains +-- proprietary and confidential information. This file is made +-- available to authorized BATM customers on the express +-- condition that neither it, nor any of the information contained +-- therein, shall be disclosed to third parties or be used for any +-- purpose other than to replace, modify or upgrade firmware and/or +-- software components of BATM manufactured equipment within the +-- authorized customer's network, and that such transfer be +-- completed in accordance with the instructions provided by +-- BATM. Any other use is strictly prohibited. +-- +-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED +-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE +-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED +-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES +-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. +-- +-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER +-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS +-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR +-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY +-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE. +-- +-- ---------------------------------------------------------------------------- + +PRVT-SYNC-ETHERNET-MIB DEFINITIONS ::= BEGIN + +IMPORTS + ifIndex + FROM IF-MIB + switch + FROM PRVT-SWITCH-MIB + Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, + Unsigned32 + FROM SNMPv2-SMI + DateAndTime, RowStatus, TEXTUAL-CONVENTION, TruthValue + FROM SNMPv2-TC; + +prvtSyncEthernetMIB MODULE-IDENTITY + LAST-UPDATED "201011100000Z" + ORGANIZATION + "BATM Advanced Communication" + CONTACT-INFO + "BATM/Telco Systems Support team + Email: + For North America: techsupport@telco.com + For North Europe: support@batm.de, info@batm.de + For the rest of the world: techsupport@telco.com" + DESCRIPTION + "This is the MIB module to manage + synchronization over ethernet." + REVISION "201011100000Z" + DESCRIPTION + "Initial" + ::= { switch 170 } + + +PrvtSyncEthernetQualityLevelType ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Clock Quality Levels." + SYNTAX INTEGER { prc(2), ssuA(4), ssuB(8), sec(11), dnu(15), + stu(16), prs(17), tnc(20), st2(23), st3(26), smc(28), + st3e(29), prov(30), dus(31), invalid(64), failed(65) } + +prvtSyncEthernetMIBNotifications OBJECT IDENTIFIER + ::= { prvtSyncEthernetMIB 0 } + +prvtSyncEthernetMIBObjects OBJECT IDENTIFIER + ::= { prvtSyncEthernetMIB 1 } + +syncEthernetHoldOffTime OBJECT-TYPE + SYNTAX Integer32 (300..1800) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timeout value, in millisseconds, for the hold-off timer." + ::= { prvtSyncEthernetMIBObjects 1 } + +syncEthernetWaitToRestoreTime OBJECT-TYPE + SYNTAX Integer32 (0..12) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timeout value, in minutes, for the wait-to-restore timer." + ::= { prvtSyncEthernetMIBObjects 2 } + +syncEthernetG781OptionMode OBJECT-TYPE + SYNTAX INTEGER { option1(1), option2(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify which G.781 option mode to operate in." + ::= { prvtSyncEthernetMIBObjects 3 } + +syncEthernetClockSourceTable OBJECT-TYPE + SYNTAX SEQUENCE OF SyncEthernetClockSourceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Source clock synchronization table." + ::= { prvtSyncEthernetMIBObjects 10 } + +syncEthernetClockSourceEntry OBJECT-TYPE + SYNTAX SyncEthernetClockSourceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Source clock synchronization entry." + INDEX { ifIndex } + ::= { syncEthernetClockSourceTable 1 } + +SyncEthernetClockSourceEntry ::= SEQUENCE { + syncEthernetClockSourceRowStatus RowStatus, + syncEthernetClockSourceAdminStatus INTEGER, + syncEthernetClockSourceEsmc TruthValue, + syncEthernetClockSourceFrequency Unsigned32, + syncEthernetClockSourceQuality PrvtSyncEthernetQualityLevelType, + syncEthernetClockSourceQualityChangeNotify TruthValue, + syncEthernetClockSourceRecvQualityLevel PrvtSyncEthernetQualityLevelType, + syncEthernetClockSourceLastRecvEsmcPduTime DateAndTime, + syncEthernetClockSourceLastRecvEsmcErrorPduTime DateAndTime, + syncEthernetClockSourceLastRecvEsmcPduType Unsigned32, + syncEthernetClockSourceLastRecvLastError Unsigned32, + syncEthernetClockSourceNumRecvEsmcPdu Unsigned32, + syncEthernetClockSourceNumDiscEsmcPdu Unsigned32, + syncEthernetClockSourceNumSignalFail Unsigned32, + syncEthernetClockSourceQualityInvalidNotify TruthValue, + syncEthernetClockSourceEsmcInvalidNotify TruthValue +} + +syncEthernetClockSourceRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Clock source synchronization table rowstatus." + ::= { syncEthernetClockSourceEntry 2 } + +syncEthernetClockSourceAdminStatus OBJECT-TYPE + SYNTAX INTEGER { up(1), down(2) } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Enable clock source." + ::= { syncEthernetClockSourceEntry 3 } + +syncEthernetClockSourceEsmc OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Enable receiving ESMC messages (Synchronization Status Messages). + Only applicable for BITS clock sources." + ::= { syncEthernetClockSourceEntry 4 } + +syncEthernetClockSourceFrequency OBJECT-TYPE + SYNTAX Unsigned32 (0..2431) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specify input frequency - N*8kHz + Only applicable for BITS clock sources." + ::= { syncEthernetClockSourceEntry 5 } + +syncEthernetClockSourceQuality OBJECT-TYPE + SYNTAX PrvtSyncEthernetQualityLevelType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specify quality level + In G781-option I mode, valid values are prs, ssuA, ssuB, dnu. + In G781-option II mode, valid values are stu, prs, tnc, st2, st3, smc, st3e, dus, prov." + ::= { syncEthernetClockSourceEntry 6 } + +syncEthernetClockSourceQualityChangeNotify OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Enable quality level change notifications" + ::= { syncEthernetClockSourceEntry 7 } + +syncEthernetClockSourceRecvQualityLevel OBJECT-TYPE + SYNTAX PrvtSyncEthernetQualityLevelType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The received quality level value." + ::= { syncEthernetClockSourceEntry 8 } + +syncEthernetClockSourceLastRecvEsmcPduTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time elapsed since the last valid ESMC message received" + ::= { syncEthernetClockSourceEntry 9 } + +syncEthernetClockSourceLastRecvEsmcErrorPduTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time elapsed since the last invalid ESMC message received" + ::= { syncEthernetClockSourceEntry 10 } + +syncEthernetClockSourceLastRecvEsmcPduType OBJECT-TYPE + SYNTAX Unsigned32 (0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Last received ESMC message type" + ::= { syncEthernetClockSourceEntry 11 } + +syncEthernetClockSourceLastRecvLastError OBJECT-TYPE + SYNTAX Unsigned32 (0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Last error code" + ::= { syncEthernetClockSourceEntry 12 } + +syncEthernetClockSourceNumRecvEsmcPdu OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of received ESMC messages" + ::= { syncEthernetClockSourceEntry 13 } + +syncEthernetClockSourceNumDiscEsmcPdu OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of discarded ESMC messages" + ::= { syncEthernetClockSourceEntry 14 } + +syncEthernetClockSourceNumSignalFail OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of generated signal failure events" + ::= { syncEthernetClockSourceEntry 15 } + +syncEthernetClockSourceQualityInvalidNotify OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Enable invalid quality notifications" + ::= { syncEthernetClockSourceEntry 16 } + +syncEthernetClockSourceEsmcInvalidNotify OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Enable invalid ESMC notifications" + ::= { syncEthernetClockSourceEntry 17 } + +syncEthernetClockOutputTable OBJECT-TYPE + SYNTAX SEQUENCE OF SyncEthernetClockOutputEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Output clock synchronization table." + ::= { prvtSyncEthernetMIBObjects 12 } + +syncEthernetClockOutputEntry OBJECT-TYPE + SYNTAX SyncEthernetClockOutputEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Output clock synchronization entry." + INDEX { ifIndex } + ::= { syncEthernetClockOutputTable 1 } + +SyncEthernetClockOutputEntry ::= SEQUENCE { + syncEthernetClockOutputRowStatus RowStatus, + syncEthernetClockOutputEsmc TruthValue, + syncEthernetClockOutputFrequency Unsigned32, + syncEthernetClockOutputDpll Integer32, + syncEthernetClockOutputQualityLevel PrvtSyncEthernetQualityLevelType, + syncEthernetClockOutputLastQualityLevelChange DateAndTime, + syncEthernetClockOutputMsgEvent TruthValue, + syncEthernetClockOutputNumTransmittedEsmcPdu Unsigned32, + syncEthernetClockOutputNumTransmittedEventEsmcPdu Unsigned32 +} + +syncEthernetClockOutputRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "syncEthernetClockOutput table rowStatus" + ::= { syncEthernetClockOutputEntry 2 } + +syncEthernetClockOutputEsmc OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Enable sending ESMC messages + Only applicable for BITS clock outputs." + ::= { syncEthernetClockOutputEntry 3 } + +syncEthernetClockOutputFrequency OBJECT-TYPE + SYNTAX Unsigned32 (0..2431) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specify output frequency - N*8kHz + Only applicable for BITS clock outputs." + ::= { syncEthernetClockOutputEntry 4 } + +syncEthernetClockOutputDpll OBJECT-TYPE + SYNTAX Integer32 (0..1) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Assign output clock to DPLL + Only applicable for BITS clock outputs. + Must be set to the syncEthernetDpllModuleId value of an existing + row in syncEthernetDpllTable." + ::= { syncEthernetClockOutputEntry 5 } + +syncEthernetClockOutputQualityLevel OBJECT-TYPE + SYNTAX PrvtSyncEthernetQualityLevelType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Last quality level value sent" + ::= { syncEthernetClockOutputEntry 6 } + +syncEthernetClockOutputLastQualityLevelChange OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time elapsed since the last quality level change" + ::= { syncEthernetClockOutputEntry 7 } + +syncEthernetClockOutputMsgEvent OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Last ESMC message type sent" + ::= { syncEthernetClockOutputEntry 8 } + +syncEthernetClockOutputNumTransmittedEsmcPdu OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of ESMC messages sent" + ::= { syncEthernetClockOutputEntry 9 } + +syncEthernetClockOutputNumTransmittedEventEsmcPdu OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of ESMC messages sent" + ::= { syncEthernetClockOutputEntry 10 } + +syncEthernetDpllTable OBJECT-TYPE + SYNTAX SEQUENCE OF SyncEthernetDpllEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Synchronization DPLL table" + ::= { prvtSyncEthernetMIBObjects 14 } + +syncEthernetDpllEntry OBJECT-TYPE + SYNTAX SyncEthernetDpllEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Synchronization DPLL entry" + INDEX { syncEthernetDpllModuleId } + ::= { syncEthernetDpllTable 1 } + +SyncEthernetDpllEntry ::= SEQUENCE { + syncEthernetDpllModuleId Integer32, + syncEthernetDpllRowStatus RowStatus, + syncEthernetDpllAdminStatus INTEGER, + syncEthernetDpllReferenceSelection INTEGER, + syncEthernetDpllEnableQualityLevel TruthValue, + syncEthernetDpllStatusChangeNotify TruthValue, + syncEthernetDpllReferenceChangeNotify TruthValue, + syncEthernetDpllStatus INTEGER, + syncEthernetDpllStatusLastChange DateAndTime, + syncEthernetDpllSystemQualityLevel PrvtSyncEthernetQualityLevelType, + syncEthernetDpllSystemQualityLevelLastChange DateAndTime, + syncEthernetDpllSelectedReferenceClock OCTET STRING, + syncEthernetDpllSelectedReferenceClockChange DateAndTime +} + +syncEthernetDpllModuleId OBJECT-TYPE + SYNTAX Integer32 (0..1) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Synchronization DPLL module index" + ::= { syncEthernetDpllEntry 1 } + +syncEthernetDpllRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Synchronization DPLL rowstatus" + ::= { syncEthernetDpllEntry 2 } + +syncEthernetDpllAdminStatus OBJECT-TYPE + SYNTAX INTEGER { up(1), down(2) } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Administrative status of the DPLL" + ::= { syncEthernetDpllEntry 3 } + +syncEthernetDpllReferenceSelection OBJECT-TYPE + SYNTAX INTEGER { freerun(1), static(2), g781(3) } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specify reference selection mode" + ::= { syncEthernetDpllEntry 4 } + +syncEthernetDpllEnableQualityLevel OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Enable reference selection based on quality level + Only applicable when syncEthernetDpllReferenceSelection equals g781." + ::= { syncEthernetDpllEntry 5 } + +syncEthernetDpllStatusChangeNotify OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Enable DPLL status change notifications" + ::= { syncEthernetDpllEntry 6 } + +syncEthernetDpllReferenceChangeNotify OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Enable reference clock change notifications" + ::= { syncEthernetDpllEntry 7 } + +syncEthernetDpllStatus OBJECT-TYPE + SYNTAX INTEGER { freerun(0), locked(1), holdover(2), + refFailure(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "DPLL operational status" + ::= { syncEthernetDpllEntry 8 } + +syncEthernetDpllStatusLastChange OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time since last DPLL status change" + ::= { syncEthernetDpllEntry 9 } + +syncEthernetDpllSystemQualityLevel OBJECT-TYPE + SYNTAX PrvtSyncEthernetQualityLevelType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "System quality level" + ::= { syncEthernetDpllEntry 10 } + +syncEthernetDpllSystemQualityLevelLastChange OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time since last system quality level change" + ::= { syncEthernetDpllEntry 11 } + +syncEthernetDpllSelectedReferenceClock OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The selected reference clock source" + ::= { syncEthernetDpllEntry 12 } + +syncEthernetDpllSelectedReferenceClockChange OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time since last reference clock change" + ::= { syncEthernetDpllEntry 13 } + +syncEthernetDpllClkRefTable OBJECT-TYPE + SYNTAX SEQUENCE OF SyncEthernetDpllClkRefEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Synchronization DPLL clock reference table" + ::= { prvtSyncEthernetMIBObjects 16 } + +syncEthernetDpllClkRefEntry OBJECT-TYPE + SYNTAX SyncEthernetDpllClkRefEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Synchronization DPLL clock reference entry" + INDEX { syncEthernetDpllModuleId, ifIndex } + ::= { syncEthernetDpllClkRefTable 1 } + +SyncEthernetDpllClkRefEntry ::= SEQUENCE { + syncEthernetDpllClkRefRowStatus RowStatus, + syncEthernetDpllClkRefPriority Unsigned32, + syncEthernetDpllClkRefLockOut TruthValue, + syncEthernetDpllClkRefFailStatus Integer32 +} + +syncEthernetDpllClkRefRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Synchronization DPLL clock reference rowstatus" + ::= { syncEthernetDpllClkRefEntry 2 } + +syncEthernetDpllClkRefPriority OBJECT-TYPE + SYNTAX Unsigned32 (0..256) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specify reference clock priority" + ::= { syncEthernetDpllClkRefEntry 3 } + +syncEthernetDpllClkRefLockOut OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Lock reference clock" + ::= { syncEthernetDpllClkRefEntry 4 } + +syncEthernetDpllClkRefFailStatus OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "DPLL reference clock status" + ::= { syncEthernetDpllClkRefEntry 5 } + +syncEthernetInvalidESMC NOTIFICATION-TYPE + OBJECTS { syncEthernetClockSourceLastRecvLastError } + STATUS current + DESCRIPTION + "Invalid ESMC has been received." + ::= { prvtSyncEthernetMIBNotifications 1 } + +syncEthernetQualityLevelChange NOTIFICATION-TYPE + OBJECTS { syncEthernetClockSourceQuality } + STATUS current + DESCRIPTION + "Current value of syncEthernetClockSourceQuality has + been changed." + ::= { prvtSyncEthernetMIBNotifications 2 } + +syncEthernetInvalidQualityLevelReceived NOTIFICATION-TYPE + OBJECTS { syncEthernetClockSourceRecvQualityLevel } + STATUS current + DESCRIPTION + "Invalid Quality level equals to QL-INVx has been received." + ::= { prvtSyncEthernetMIBNotifications 3 } + +syncEthernetDPLLReferenceChange NOTIFICATION-TYPE + OBJECTS { syncEthernetDpllSelectedReferenceClockChange } + STATUS current + DESCRIPTION + "DPLL's reference clock changed." + ::= { prvtSyncEthernetMIBNotifications 4 } + +syncEthernetDPLLChanged NOTIFICATION-TYPE + OBJECTS { syncEthernetDpllStatus } + STATUS current + DESCRIPTION + "Some of the DPLL's operational status changes." + ::= { prvtSyncEthernetMIBNotifications 5 } + +syncEthernetDPLLLockFailed NOTIFICATION-TYPE + OBJECTS { syncEthernetDpllClkRefFailStatus } + STATUS current + DESCRIPTION + "If after new Reference selection the DPLL can't + lock onto it, this will affect the Clock Source + associated with that reference" + ::= { prvtSyncEthernetMIBNotifications 6 } + +END -- end of module PRVT-SYNC-ETHERNET-MIB. |