diff --git a/MIBS/telco-systems/binox/PRVT-SYNC-ETHERNET-MIB b/MIBS/telco-systems/binox/PRVT-SYNC-ETHERNET-MIB
new file mode 100644
index 0000000..5055a6d
--- /dev/null
+++ b/MIBS/telco-systems/binox/PRVT-SYNC-ETHERNET-MIB
@@ -0,0 +1,624 @@
+-- *********************************************************************
+-- **
+-- ** BATM Advanced Communications.
+-- **
+-- *********************************************************************
+-- ** Filename: PRVT-SYNC-ETHERNET-MIB.mib
+-- ** Project: T-Metro Switches.
+-- ** Purpose: Private MIB
+-- *********************************************************************
+-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
+-- WARNING:
+--
+-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
+--
+-- This file is the property of BATM Advanced Communications and contains
+-- proprietary and confidential information. This file is made
+-- available to authorized BATM customers on the express
+-- condition that neither it, nor any of the information contained
+-- therein, shall be disclosed to third parties or be used for any
+-- purpose other than to replace, modify or upgrade firmware and/or
+-- software components of BATM manufactured equipment within the
+-- authorized customer's network, and that such transfer be
+-- completed in accordance with the instructions provided by
+-- BATM. Any other use is strictly prohibited.
+--
+-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
+-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
+-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
+-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
+-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
+--
+-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
+-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
+-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
+-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
+-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
+--
+-- ----------------------------------------------------------------------------
+
+PRVT-SYNC-ETHERNET-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ ifIndex
+ FROM IF-MIB
+ switch
+ FROM PRVT-SWITCH-MIB
+ Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
+ Unsigned32
+ FROM SNMPv2-SMI
+ DateAndTime, RowStatus, TEXTUAL-CONVENTION, TruthValue
+ FROM SNMPv2-TC;
+
+prvtSyncEthernetMIB MODULE-IDENTITY
+ LAST-UPDATED "201011100000Z"
+ ORGANIZATION
+ "BATM Advanced Communication"
+ CONTACT-INFO
+ "BATM/Telco Systems Support team
+ Email:
+ For North America: techsupport@telco.com
+ For North Europe: support@batm.de, info@batm.de
+ For the rest of the world: techsupport@telco.com"
+ DESCRIPTION
+ "This is the MIB module to manage
+ synchronization over ethernet."
+ REVISION "201011100000Z"
+ DESCRIPTION
+ "Initial"
+ ::= { switch 170 }
+
+
+PrvtSyncEthernetQualityLevelType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Clock Quality Levels."
+ SYNTAX INTEGER { prc(2), ssuA(4), ssuB(8), sec(11), dnu(15),
+ stu(16), prs(17), tnc(20), st2(23), st3(26), smc(28),
+ st3e(29), prov(30), dus(31), invalid(64), failed(65) }
+
+prvtSyncEthernetMIBNotifications OBJECT IDENTIFIER
+ ::= { prvtSyncEthernetMIB 0 }
+
+prvtSyncEthernetMIBObjects OBJECT IDENTIFIER
+ ::= { prvtSyncEthernetMIB 1 }
+
+syncEthernetHoldOffTime OBJECT-TYPE
+ SYNTAX Integer32 (300..1800)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timeout value, in millisseconds, for the hold-off timer."
+ ::= { prvtSyncEthernetMIBObjects 1 }
+
+syncEthernetWaitToRestoreTime OBJECT-TYPE
+ SYNTAX Integer32 (0..12)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timeout value, in minutes, for the wait-to-restore timer."
+ ::= { prvtSyncEthernetMIBObjects 2 }
+
+syncEthernetG781OptionMode OBJECT-TYPE
+ SYNTAX INTEGER { option1(1), option2(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specify which G.781 option mode to operate in."
+ ::= { prvtSyncEthernetMIBObjects 3 }
+
+syncEthernetClockSourceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SyncEthernetClockSourceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Source clock synchronization table."
+ ::= { prvtSyncEthernetMIBObjects 10 }
+
+syncEthernetClockSourceEntry OBJECT-TYPE
+ SYNTAX SyncEthernetClockSourceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Source clock synchronization entry."
+ INDEX { ifIndex }
+ ::= { syncEthernetClockSourceTable 1 }
+
+SyncEthernetClockSourceEntry ::= SEQUENCE {
+ syncEthernetClockSourceRowStatus RowStatus,
+ syncEthernetClockSourceAdminStatus INTEGER,
+ syncEthernetClockSourceEsmc TruthValue,
+ syncEthernetClockSourceFrequency Unsigned32,
+ syncEthernetClockSourceQuality PrvtSyncEthernetQualityLevelType,
+ syncEthernetClockSourceQualityChangeNotify TruthValue,
+ syncEthernetClockSourceRecvQualityLevel PrvtSyncEthernetQualityLevelType,
+ syncEthernetClockSourceLastRecvEsmcPduTime DateAndTime,
+ syncEthernetClockSourceLastRecvEsmcErrorPduTime DateAndTime,
+ syncEthernetClockSourceLastRecvEsmcPduType Unsigned32,
+ syncEthernetClockSourceLastRecvLastError Unsigned32,
+ syncEthernetClockSourceNumRecvEsmcPdu Unsigned32,
+ syncEthernetClockSourceNumDiscEsmcPdu Unsigned32,
+ syncEthernetClockSourceNumSignalFail Unsigned32,
+ syncEthernetClockSourceQualityInvalidNotify TruthValue,
+ syncEthernetClockSourceEsmcInvalidNotify TruthValue
+}
+
+syncEthernetClockSourceRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Clock source synchronization table rowstatus."
+ ::= { syncEthernetClockSourceEntry 2 }
+
+syncEthernetClockSourceAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER { up(1), down(2) }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Enable clock source."
+ ::= { syncEthernetClockSourceEntry 3 }
+
+syncEthernetClockSourceEsmc OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Enable receiving ESMC messages (Synchronization Status Messages).
+ Only applicable for BITS clock sources."
+ ::= { syncEthernetClockSourceEntry 4 }
+
+syncEthernetClockSourceFrequency OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2431)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Specify input frequency - N*8kHz
+ Only applicable for BITS clock sources."
+ ::= { syncEthernetClockSourceEntry 5 }
+
+syncEthernetClockSourceQuality OBJECT-TYPE
+ SYNTAX PrvtSyncEthernetQualityLevelType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Specify quality level
+ In G781-option I mode, valid values are prs, ssuA, ssuB, dnu.
+ In G781-option II mode, valid values are stu, prs, tnc, st2, st3, smc, st3e, dus, prov."
+ ::= { syncEthernetClockSourceEntry 6 }
+
+syncEthernetClockSourceQualityChangeNotify OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Enable quality level change notifications"
+ ::= { syncEthernetClockSourceEntry 7 }
+
+syncEthernetClockSourceRecvQualityLevel OBJECT-TYPE
+ SYNTAX PrvtSyncEthernetQualityLevelType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The received quality level value."
+ ::= { syncEthernetClockSourceEntry 8 }
+
+syncEthernetClockSourceLastRecvEsmcPduTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time elapsed since the last valid ESMC message received"
+ ::= { syncEthernetClockSourceEntry 9 }
+
+syncEthernetClockSourceLastRecvEsmcErrorPduTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time elapsed since the last invalid ESMC message received"
+ ::= { syncEthernetClockSourceEntry 10 }
+
+syncEthernetClockSourceLastRecvEsmcPduType OBJECT-TYPE
+ SYNTAX Unsigned32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Last received ESMC message type"
+ ::= { syncEthernetClockSourceEntry 11 }
+
+syncEthernetClockSourceLastRecvLastError OBJECT-TYPE
+ SYNTAX Unsigned32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Last error code"
+ ::= { syncEthernetClockSourceEntry 12 }
+
+syncEthernetClockSourceNumRecvEsmcPdu OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of received ESMC messages"
+ ::= { syncEthernetClockSourceEntry 13 }
+
+syncEthernetClockSourceNumDiscEsmcPdu OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of discarded ESMC messages"
+ ::= { syncEthernetClockSourceEntry 14 }
+
+syncEthernetClockSourceNumSignalFail OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of generated signal failure events"
+ ::= { syncEthernetClockSourceEntry 15 }
+
+syncEthernetClockSourceQualityInvalidNotify OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Enable invalid quality notifications"
+ ::= { syncEthernetClockSourceEntry 16 }
+
+syncEthernetClockSourceEsmcInvalidNotify OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Enable invalid ESMC notifications"
+ ::= { syncEthernetClockSourceEntry 17 }
+
+syncEthernetClockOutputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SyncEthernetClockOutputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Output clock synchronization table."
+ ::= { prvtSyncEthernetMIBObjects 12 }
+
+syncEthernetClockOutputEntry OBJECT-TYPE
+ SYNTAX SyncEthernetClockOutputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Output clock synchronization entry."
+ INDEX { ifIndex }
+ ::= { syncEthernetClockOutputTable 1 }
+
+SyncEthernetClockOutputEntry ::= SEQUENCE {
+ syncEthernetClockOutputRowStatus RowStatus,
+ syncEthernetClockOutputEsmc TruthValue,
+ syncEthernetClockOutputFrequency Unsigned32,
+ syncEthernetClockOutputDpll Integer32,
+ syncEthernetClockOutputQualityLevel PrvtSyncEthernetQualityLevelType,
+ syncEthernetClockOutputLastQualityLevelChange DateAndTime,
+ syncEthernetClockOutputMsgEvent TruthValue,
+ syncEthernetClockOutputNumTransmittedEsmcPdu Unsigned32,
+ syncEthernetClockOutputNumTransmittedEventEsmcPdu Unsigned32
+}
+
+syncEthernetClockOutputRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "syncEthernetClockOutput table rowStatus"
+ ::= { syncEthernetClockOutputEntry 2 }
+
+syncEthernetClockOutputEsmc OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Enable sending ESMC messages
+ Only applicable for BITS clock outputs."
+ ::= { syncEthernetClockOutputEntry 3 }
+
+syncEthernetClockOutputFrequency OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2431)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Specify output frequency - N*8kHz
+ Only applicable for BITS clock outputs."
+ ::= { syncEthernetClockOutputEntry 4 }
+
+syncEthernetClockOutputDpll OBJECT-TYPE
+ SYNTAX Integer32 (0..1)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Assign output clock to DPLL
+ Only applicable for BITS clock outputs.
+ Must be set to the syncEthernetDpllModuleId value of an existing
+ row in syncEthernetDpllTable."
+ ::= { syncEthernetClockOutputEntry 5 }
+
+syncEthernetClockOutputQualityLevel OBJECT-TYPE
+ SYNTAX PrvtSyncEthernetQualityLevelType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Last quality level value sent"
+ ::= { syncEthernetClockOutputEntry 6 }
+
+syncEthernetClockOutputLastQualityLevelChange OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time elapsed since the last quality level change"
+ ::= { syncEthernetClockOutputEntry 7 }
+
+syncEthernetClockOutputMsgEvent OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Last ESMC message type sent"
+ ::= { syncEthernetClockOutputEntry 8 }
+
+syncEthernetClockOutputNumTransmittedEsmcPdu OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of ESMC messages sent"
+ ::= { syncEthernetClockOutputEntry 9 }
+
+syncEthernetClockOutputNumTransmittedEventEsmcPdu OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of ESMC messages sent"
+ ::= { syncEthernetClockOutputEntry 10 }
+
+syncEthernetDpllTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SyncEthernetDpllEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Synchronization DPLL table"
+ ::= { prvtSyncEthernetMIBObjects 14 }
+
+syncEthernetDpllEntry OBJECT-TYPE
+ SYNTAX SyncEthernetDpllEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Synchronization DPLL entry"
+ INDEX { syncEthernetDpllModuleId }
+ ::= { syncEthernetDpllTable 1 }
+
+SyncEthernetDpllEntry ::= SEQUENCE {
+ syncEthernetDpllModuleId Integer32,
+ syncEthernetDpllRowStatus RowStatus,
+ syncEthernetDpllAdminStatus INTEGER,
+ syncEthernetDpllReferenceSelection INTEGER,
+ syncEthernetDpllEnableQualityLevel TruthValue,
+ syncEthernetDpllStatusChangeNotify TruthValue,
+ syncEthernetDpllReferenceChangeNotify TruthValue,
+ syncEthernetDpllStatus INTEGER,
+ syncEthernetDpllStatusLastChange DateAndTime,
+ syncEthernetDpllSystemQualityLevel PrvtSyncEthernetQualityLevelType,
+ syncEthernetDpllSystemQualityLevelLastChange DateAndTime,
+ syncEthernetDpllSelectedReferenceClock OCTET STRING,
+ syncEthernetDpllSelectedReferenceClockChange DateAndTime
+}
+
+syncEthernetDpllModuleId OBJECT-TYPE
+ SYNTAX Integer32 (0..1)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Synchronization DPLL module index"
+ ::= { syncEthernetDpllEntry 1 }
+
+syncEthernetDpllRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Synchronization DPLL rowstatus"
+ ::= { syncEthernetDpllEntry 2 }
+
+syncEthernetDpllAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER { up(1), down(2) }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Administrative status of the DPLL"
+ ::= { syncEthernetDpllEntry 3 }
+
+syncEthernetDpllReferenceSelection OBJECT-TYPE
+ SYNTAX INTEGER { freerun(1), static(2), g781(3) }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Specify reference selection mode"
+ ::= { syncEthernetDpllEntry 4 }
+
+syncEthernetDpllEnableQualityLevel OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Enable reference selection based on quality level
+ Only applicable when syncEthernetDpllReferenceSelection equals g781."
+ ::= { syncEthernetDpllEntry 5 }
+
+syncEthernetDpllStatusChangeNotify OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Enable DPLL status change notifications"
+ ::= { syncEthernetDpllEntry 6 }
+
+syncEthernetDpllReferenceChangeNotify OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Enable reference clock change notifications"
+ ::= { syncEthernetDpllEntry 7 }
+
+syncEthernetDpllStatus OBJECT-TYPE
+ SYNTAX INTEGER { freerun(0), locked(1), holdover(2),
+ refFailure(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "DPLL operational status"
+ ::= { syncEthernetDpllEntry 8 }
+
+syncEthernetDpllStatusLastChange OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time since last DPLL status change"
+ ::= { syncEthernetDpllEntry 9 }
+
+syncEthernetDpllSystemQualityLevel OBJECT-TYPE
+ SYNTAX PrvtSyncEthernetQualityLevelType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "System quality level"
+ ::= { syncEthernetDpllEntry 10 }
+
+syncEthernetDpllSystemQualityLevelLastChange OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time since last system quality level change"
+ ::= { syncEthernetDpllEntry 11 }
+
+syncEthernetDpllSelectedReferenceClock OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The selected reference clock source"
+ ::= { syncEthernetDpllEntry 12 }
+
+syncEthernetDpllSelectedReferenceClockChange OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time since last reference clock change"
+ ::= { syncEthernetDpllEntry 13 }
+
+syncEthernetDpllClkRefTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SyncEthernetDpllClkRefEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Synchronization DPLL clock reference table"
+ ::= { prvtSyncEthernetMIBObjects 16 }
+
+syncEthernetDpllClkRefEntry OBJECT-TYPE
+ SYNTAX SyncEthernetDpllClkRefEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Synchronization DPLL clock reference entry"
+ INDEX { syncEthernetDpllModuleId, ifIndex }
+ ::= { syncEthernetDpllClkRefTable 1 }
+
+SyncEthernetDpllClkRefEntry ::= SEQUENCE {
+ syncEthernetDpllClkRefRowStatus RowStatus,
+ syncEthernetDpllClkRefPriority Unsigned32,
+ syncEthernetDpllClkRefLockOut TruthValue,
+ syncEthernetDpllClkRefFailStatus Integer32
+}
+
+syncEthernetDpllClkRefRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Synchronization DPLL clock reference rowstatus"
+ ::= { syncEthernetDpllClkRefEntry 2 }
+
+syncEthernetDpllClkRefPriority OBJECT-TYPE
+ SYNTAX Unsigned32 (0..256)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Specify reference clock priority"
+ ::= { syncEthernetDpllClkRefEntry 3 }
+
+syncEthernetDpllClkRefLockOut OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Lock reference clock"
+ ::= { syncEthernetDpllClkRefEntry 4 }
+
+syncEthernetDpllClkRefFailStatus OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "DPLL reference clock status"
+ ::= { syncEthernetDpllClkRefEntry 5 }
+
+syncEthernetInvalidESMC NOTIFICATION-TYPE
+ OBJECTS { syncEthernetClockSourceLastRecvLastError }
+ STATUS current
+ DESCRIPTION
+ "Invalid ESMC has been received."
+ ::= { prvtSyncEthernetMIBNotifications 1 }
+
+syncEthernetQualityLevelChange NOTIFICATION-TYPE
+ OBJECTS { syncEthernetClockSourceQuality }
+ STATUS current
+ DESCRIPTION
+ "Current value of syncEthernetClockSourceQuality has
+ been changed."
+ ::= { prvtSyncEthernetMIBNotifications 2 }
+
+syncEthernetInvalidQualityLevelReceived NOTIFICATION-TYPE
+ OBJECTS { syncEthernetClockSourceRecvQualityLevel }
+ STATUS current
+ DESCRIPTION
+ "Invalid Quality level equals to QL-INVx has been received."
+ ::= { prvtSyncEthernetMIBNotifications 3 }
+
+syncEthernetDPLLReferenceChange NOTIFICATION-TYPE
+ OBJECTS { syncEthernetDpllSelectedReferenceClockChange }
+ STATUS current
+ DESCRIPTION
+ "DPLL's reference clock changed."
+ ::= { prvtSyncEthernetMIBNotifications 4 }
+
+syncEthernetDPLLChanged NOTIFICATION-TYPE
+ OBJECTS { syncEthernetDpllStatus }
+ STATUS current
+ DESCRIPTION
+ "Some of the DPLL's operational status changes."
+ ::= { prvtSyncEthernetMIBNotifications 5 }
+
+syncEthernetDPLLLockFailed NOTIFICATION-TYPE
+ OBJECTS { syncEthernetDpllClkRefFailStatus }
+ STATUS current
+ DESCRIPTION
+ "If after new Reference selection the DPLL can't
+ lock onto it, this will affect the Clock Source
+ associated with that reference"
+ ::= { prvtSyncEthernetMIBNotifications 6 }
+
+END -- end of module PRVT-SYNC-ETHERNET-MIB.