summaryrefslogtreecommitdiff
path: root/MIBS/telco-systems/binox/PRVT-SYNC-ETHERNET-MIB
blob: 5055a6d27cde88d269db77b6cd0b0507b7adc463 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-SYNC-ETHERNET-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------

PRVT-SYNC-ETHERNET-MIB DEFINITIONS ::= BEGIN

IMPORTS
    ifIndex
        FROM IF-MIB
    switch
        FROM PRVT-SWITCH-MIB
    Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, 
    Unsigned32
        FROM SNMPv2-SMI
    DateAndTime, RowStatus, TEXTUAL-CONVENTION, TruthValue
        FROM SNMPv2-TC;

prvtSyncEthernetMIB MODULE-IDENTITY
    LAST-UPDATED "201011100000Z"
    ORGANIZATION 
        "BATM Advanced Communication"
    CONTACT-INFO 
        "BATM/Telco Systems Support team
         Email:
         For North America: techsupport@telco.com
         For North Europe: support@batm.de, info@batm.de
         For the rest of the world: techsupport@telco.com"
    DESCRIPTION 
        "This is the MIB module to manage
         synchronization over ethernet."
    REVISION    "201011100000Z"
    DESCRIPTION 
        "Initial"
    ::= { switch 170 }


PrvtSyncEthernetQualityLevelType ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION 
        "Clock Quality Levels."
    SYNTAX      INTEGER { prc(2), ssuA(4), ssuB(8), sec(11), dnu(15), 
                    stu(16), prs(17), tnc(20), st2(23), st3(26), smc(28), 
                    st3e(29), prov(30), dus(31), invalid(64), failed(65) }

prvtSyncEthernetMIBNotifications OBJECT IDENTIFIER
    ::= { prvtSyncEthernetMIB 0 }

prvtSyncEthernetMIBObjects OBJECT IDENTIFIER
    ::= { prvtSyncEthernetMIB 1 }

syncEthernetHoldOffTime OBJECT-TYPE
    SYNTAX      Integer32 (300..1800)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION 
        "Timeout value, in millisseconds, for the hold-off timer."
    ::= { prvtSyncEthernetMIBObjects 1 }

syncEthernetWaitToRestoreTime OBJECT-TYPE
    SYNTAX      Integer32 (0..12)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION 
        "Timeout value, in minutes, for the wait-to-restore timer."
    ::= { prvtSyncEthernetMIBObjects 2 }

syncEthernetG781OptionMode OBJECT-TYPE
    SYNTAX      INTEGER { option1(1), option2(2) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION 
        "Specify which G.781 option mode to operate in."
    ::= { prvtSyncEthernetMIBObjects 3 }

syncEthernetClockSourceTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF SyncEthernetClockSourceEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "Source clock synchronization table."
    ::= { prvtSyncEthernetMIBObjects 10 }

syncEthernetClockSourceEntry OBJECT-TYPE
    SYNTAX      SyncEthernetClockSourceEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "Source clock synchronization entry."
    INDEX       { ifIndex }
    ::= { syncEthernetClockSourceTable 1 }

SyncEthernetClockSourceEntry ::= SEQUENCE {
    syncEthernetClockSourceRowStatus                    RowStatus,
    syncEthernetClockSourceAdminStatus                  INTEGER,
    syncEthernetClockSourceEsmc                         TruthValue,
    syncEthernetClockSourceFrequency                    Unsigned32,
    syncEthernetClockSourceQuality                      PrvtSyncEthernetQualityLevelType,
    syncEthernetClockSourceQualityChangeNotify          TruthValue,
    syncEthernetClockSourceRecvQualityLevel             PrvtSyncEthernetQualityLevelType,
    syncEthernetClockSourceLastRecvEsmcPduTime          DateAndTime,
    syncEthernetClockSourceLastRecvEsmcErrorPduTime     DateAndTime,
    syncEthernetClockSourceLastRecvEsmcPduType          Unsigned32,
    syncEthernetClockSourceLastRecvLastError            Unsigned32,
    syncEthernetClockSourceNumRecvEsmcPdu               Unsigned32,
    syncEthernetClockSourceNumDiscEsmcPdu               Unsigned32,
    syncEthernetClockSourceNumSignalFail                Unsigned32,
    syncEthernetClockSourceQualityInvalidNotify         TruthValue,
    syncEthernetClockSourceEsmcInvalidNotify            TruthValue
}

syncEthernetClockSourceRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Clock source synchronization table rowstatus."
    ::= { syncEthernetClockSourceEntry 2 }

syncEthernetClockSourceAdminStatus OBJECT-TYPE
    SYNTAX      INTEGER { up(1), down(2) }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Enable clock source."
    ::= { syncEthernetClockSourceEntry 3 }

syncEthernetClockSourceEsmc OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Enable receiving ESMC messages (Synchronization Status Messages).
         Only applicable for BITS clock sources."
    ::= { syncEthernetClockSourceEntry 4 }

syncEthernetClockSourceFrequency OBJECT-TYPE
    SYNTAX      Unsigned32 (0..2431)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Specify input frequency - N*8kHz
         Only applicable for BITS clock sources."
    ::= { syncEthernetClockSourceEntry 5 }

syncEthernetClockSourceQuality OBJECT-TYPE
    SYNTAX      PrvtSyncEthernetQualityLevelType
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Specify quality level
         In G781-option I mode, valid values are prs, ssuA, ssuB, dnu.
         In G781-option II mode, valid values are stu, prs, tnc, st2, st3, smc, st3e, dus, prov."
    ::= { syncEthernetClockSourceEntry 6 }

syncEthernetClockSourceQualityChangeNotify OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Enable quality level change notifications"
    ::= { syncEthernetClockSourceEntry 7 }

syncEthernetClockSourceRecvQualityLevel OBJECT-TYPE
    SYNTAX      PrvtSyncEthernetQualityLevelType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "The received quality level value."
    ::= { syncEthernetClockSourceEntry 8 }

syncEthernetClockSourceLastRecvEsmcPduTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Time elapsed since the last valid ESMC message received"
    ::= { syncEthernetClockSourceEntry 9 }

syncEthernetClockSourceLastRecvEsmcErrorPduTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Time elapsed since the last invalid ESMC message received"
    ::= { syncEthernetClockSourceEntry 10 }

syncEthernetClockSourceLastRecvEsmcPduType OBJECT-TYPE
    SYNTAX      Unsigned32 (0..255)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Last received ESMC message type"
    ::= { syncEthernetClockSourceEntry 11 }

syncEthernetClockSourceLastRecvLastError OBJECT-TYPE
    SYNTAX      Unsigned32 (0..255)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Last error code"
    ::= { syncEthernetClockSourceEntry 12 }

syncEthernetClockSourceNumRecvEsmcPdu OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Total number of received ESMC messages"
    ::= { syncEthernetClockSourceEntry 13 }

syncEthernetClockSourceNumDiscEsmcPdu OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Total number of discarded ESMC messages"
    ::= { syncEthernetClockSourceEntry 14 }

syncEthernetClockSourceNumSignalFail OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Total number of generated signal failure events"
    ::= { syncEthernetClockSourceEntry 15 }

syncEthernetClockSourceQualityInvalidNotify OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Enable invalid quality notifications"
    ::= { syncEthernetClockSourceEntry 16 }

syncEthernetClockSourceEsmcInvalidNotify OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Enable invalid ESMC notifications"
    ::= { syncEthernetClockSourceEntry 17 }

syncEthernetClockOutputTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF SyncEthernetClockOutputEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "Output clock synchronization table."
    ::= { prvtSyncEthernetMIBObjects 12 }

syncEthernetClockOutputEntry OBJECT-TYPE
    SYNTAX      SyncEthernetClockOutputEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "Output clock synchronization entry."
    INDEX       { ifIndex }
    ::= { syncEthernetClockOutputTable 1 }

SyncEthernetClockOutputEntry ::= SEQUENCE {
    syncEthernetClockOutputRowStatus                    RowStatus,
    syncEthernetClockOutputEsmc                         TruthValue,
    syncEthernetClockOutputFrequency                    Unsigned32,
    syncEthernetClockOutputDpll                         Integer32,
    syncEthernetClockOutputQualityLevel                 PrvtSyncEthernetQualityLevelType,
    syncEthernetClockOutputLastQualityLevelChange       DateAndTime,
    syncEthernetClockOutputMsgEvent                     TruthValue,
    syncEthernetClockOutputNumTransmittedEsmcPdu        Unsigned32,
    syncEthernetClockOutputNumTransmittedEventEsmcPdu   Unsigned32
}

syncEthernetClockOutputRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "syncEthernetClockOutput table rowStatus"
    ::= { syncEthernetClockOutputEntry 2 }

syncEthernetClockOutputEsmc OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Enable sending ESMC messages
         Only applicable for BITS clock outputs."
    ::= { syncEthernetClockOutputEntry 3 }

syncEthernetClockOutputFrequency OBJECT-TYPE
    SYNTAX      Unsigned32 (0..2431)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Specify output frequency - N*8kHz
         Only applicable for BITS clock outputs."
    ::= { syncEthernetClockOutputEntry 4 }

syncEthernetClockOutputDpll OBJECT-TYPE
    SYNTAX      Integer32 (0..1)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Assign output clock to DPLL
         Only applicable for BITS clock outputs.
         Must be set to the syncEthernetDpllModuleId value of an existing
         row in syncEthernetDpllTable."
    ::= { syncEthernetClockOutputEntry 5 }

syncEthernetClockOutputQualityLevel OBJECT-TYPE
    SYNTAX      PrvtSyncEthernetQualityLevelType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Last quality level value sent"
    ::= { syncEthernetClockOutputEntry 6 }

syncEthernetClockOutputLastQualityLevelChange OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Time elapsed since the last quality level change"
    ::= { syncEthernetClockOutputEntry 7 }

syncEthernetClockOutputMsgEvent OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Last ESMC message type sent"
    ::= { syncEthernetClockOutputEntry 8 }

syncEthernetClockOutputNumTransmittedEsmcPdu OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Total number of ESMC messages sent"
    ::= { syncEthernetClockOutputEntry 9 }

syncEthernetClockOutputNumTransmittedEventEsmcPdu OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Total number of ESMC messages sent"
    ::= { syncEthernetClockOutputEntry 10 }

syncEthernetDpllTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF SyncEthernetDpllEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "Synchronization DPLL table"
    ::= { prvtSyncEthernetMIBObjects 14 }

syncEthernetDpllEntry OBJECT-TYPE
    SYNTAX      SyncEthernetDpllEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "Synchronization DPLL entry"
    INDEX       { syncEthernetDpllModuleId }
    ::= { syncEthernetDpllTable 1 }

SyncEthernetDpllEntry ::= SEQUENCE {
    syncEthernetDpllModuleId                        Integer32,
    syncEthernetDpllRowStatus                       RowStatus,
    syncEthernetDpllAdminStatus                     INTEGER,
    syncEthernetDpllReferenceSelection              INTEGER,
    syncEthernetDpllEnableQualityLevel              TruthValue,
    syncEthernetDpllStatusChangeNotify              TruthValue,
    syncEthernetDpllReferenceChangeNotify           TruthValue,
    syncEthernetDpllStatus                          INTEGER,
    syncEthernetDpllStatusLastChange                DateAndTime,
    syncEthernetDpllSystemQualityLevel              PrvtSyncEthernetQualityLevelType,
    syncEthernetDpllSystemQualityLevelLastChange    DateAndTime,
    syncEthernetDpllSelectedReferenceClock          OCTET STRING,
    syncEthernetDpllSelectedReferenceClockChange    DateAndTime
}

syncEthernetDpllModuleId OBJECT-TYPE
    SYNTAX      Integer32 (0..1)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "Synchronization DPLL module index"
    ::= { syncEthernetDpllEntry 1 }

syncEthernetDpllRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Synchronization DPLL rowstatus"
    ::= { syncEthernetDpllEntry 2 }

syncEthernetDpllAdminStatus OBJECT-TYPE
    SYNTAX      INTEGER { up(1), down(2) }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Administrative status of the DPLL"
    ::= { syncEthernetDpllEntry 3 }

syncEthernetDpllReferenceSelection OBJECT-TYPE
    SYNTAX      INTEGER { freerun(1), static(2), g781(3) }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Specify reference selection mode"
    ::= { syncEthernetDpllEntry 4 }

syncEthernetDpllEnableQualityLevel OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Enable reference selection based on quality level
         Only applicable when syncEthernetDpllReferenceSelection equals g781."
    ::= { syncEthernetDpllEntry 5 }

syncEthernetDpllStatusChangeNotify OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Enable DPLL status change notifications"
    ::= { syncEthernetDpllEntry 6 }

syncEthernetDpllReferenceChangeNotify OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Enable reference clock change notifications"
    ::= { syncEthernetDpllEntry 7 }

syncEthernetDpllStatus OBJECT-TYPE
    SYNTAX      INTEGER { freerun(0), locked(1), holdover(2), 
                    refFailure(3) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "DPLL operational status"
    ::= { syncEthernetDpllEntry 8 }

syncEthernetDpllStatusLastChange OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Time since last DPLL status change"
    ::= { syncEthernetDpllEntry 9 }

syncEthernetDpllSystemQualityLevel OBJECT-TYPE
    SYNTAX      PrvtSyncEthernetQualityLevelType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "System quality level"
    ::= { syncEthernetDpllEntry 10 }

syncEthernetDpllSystemQualityLevelLastChange OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Time since last system quality level change"
    ::= { syncEthernetDpllEntry 11 }

syncEthernetDpllSelectedReferenceClock OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "The selected reference clock source"
    ::= { syncEthernetDpllEntry 12 }

syncEthernetDpllSelectedReferenceClockChange OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Time since last reference clock change"
    ::= { syncEthernetDpllEntry 13 }

syncEthernetDpllClkRefTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF SyncEthernetDpllClkRefEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "Synchronization DPLL clock reference table"
    ::= { prvtSyncEthernetMIBObjects 16 }

syncEthernetDpllClkRefEntry OBJECT-TYPE
    SYNTAX      SyncEthernetDpllClkRefEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "Synchronization DPLL clock reference entry"
    INDEX       { syncEthernetDpllModuleId, ifIndex }
    ::= { syncEthernetDpllClkRefTable 1 }

SyncEthernetDpllClkRefEntry ::= SEQUENCE {
    syncEthernetDpllClkRefRowStatus     RowStatus,
    syncEthernetDpllClkRefPriority      Unsigned32,
    syncEthernetDpllClkRefLockOut       TruthValue,
    syncEthernetDpllClkRefFailStatus    Integer32
}

syncEthernetDpllClkRefRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Synchronization DPLL clock reference rowstatus"
    ::= { syncEthernetDpllClkRefEntry 2 }

syncEthernetDpllClkRefPriority OBJECT-TYPE
    SYNTAX      Unsigned32 (0..256)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Specify reference clock priority"
    ::= { syncEthernetDpllClkRefEntry 3 }

syncEthernetDpllClkRefLockOut OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Lock reference clock"
    ::= { syncEthernetDpllClkRefEntry 4 }

syncEthernetDpllClkRefFailStatus OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "DPLL reference clock status"
    ::= { syncEthernetDpllClkRefEntry 5 }

syncEthernetInvalidESMC NOTIFICATION-TYPE
    OBJECTS     { syncEthernetClockSourceLastRecvLastError }
    STATUS      current
    DESCRIPTION 
        "Invalid ESMC has been received."
    ::= { prvtSyncEthernetMIBNotifications 1 }

syncEthernetQualityLevelChange NOTIFICATION-TYPE
    OBJECTS     { syncEthernetClockSourceQuality }
    STATUS      current
    DESCRIPTION 
        "Current value of syncEthernetClockSourceQuality has
         been changed."
    ::= { prvtSyncEthernetMIBNotifications 2 }

syncEthernetInvalidQualityLevelReceived NOTIFICATION-TYPE
    OBJECTS     { syncEthernetClockSourceRecvQualityLevel }
    STATUS      current
    DESCRIPTION 
        "Invalid Quality level equals to QL-INVx has been received."
    ::= { prvtSyncEthernetMIBNotifications 3 }

syncEthernetDPLLReferenceChange NOTIFICATION-TYPE
    OBJECTS     { syncEthernetDpllSelectedReferenceClockChange }
    STATUS      current
    DESCRIPTION 
        "DPLL's reference clock changed."
    ::= { prvtSyncEthernetMIBNotifications 4 }

syncEthernetDPLLChanged NOTIFICATION-TYPE
    OBJECTS     { syncEthernetDpllStatus }
    STATUS      current
    DESCRIPTION 
        "Some of the DPLL's operational status changes."
    ::= { prvtSyncEthernetMIBNotifications 5 }

syncEthernetDPLLLockFailed NOTIFICATION-TYPE
    OBJECTS     { syncEthernetDpllClkRefFailStatus }
    STATUS      current
    DESCRIPTION 
        "If after new Reference selection the DPLL can't
         lock onto it, this will affect the Clock Source
         associated with that reference"
    ::= { prvtSyncEthernetMIBNotifications 6 }

END -- end of module PRVT-SYNC-ETHERNET-MIB.