1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
|
-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-REDUNDANCY-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
PRVT-REDUNDANCY-MIB DEFINITIONS ::= BEGIN
IMPORTS
software
FROM PRVT-SWITCH-MIB
MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, Unsigned32
FROM SNMPv2-SMI;
prvtRedundancyMIB MODULE-IDENTITY
LAST-UPDATED "201312170000Z"
ORGANIZATION
"BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"Monitoring of components redundancy protection"
REVISION "201312170000Z"
DESCRIPTION
"Initial version."
::= { software 5 }
prvtRedundancyNotifications OBJECT IDENTIFIER
::= { prvtRedundancyMIB 0 }
prvtRedundancyObjects OBJECT IDENTIFIER
::= { prvtRedundancyMIB 1 }
prvtRedundancyChassisTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtRedundancyChassisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of slots in the chassis"
::= { prvtRedundancyObjects 1 }
prvtRedundancyChassisEntry OBJECT-TYPE
SYNTAX PrvtRedundancyChassisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in prvtRedundancyChassisTable"
INDEX { prvtRedundancyChassisSlotId }
::= { prvtRedundancyChassisTable 1 }
PrvtRedundancyChassisEntry ::= SEQUENCE {
prvtRedundancyChassisSlotId Unsigned32,
prvtRedundancyChassisLICType INTEGER,
prvtRedundancyChassisStatus INTEGER,
prvtRedundancyChassisEntryStatus INTEGER
}
prvtRedundancyChassisSlotId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index in the table."
::= { prvtRedundancyChassisEntry 1 }
prvtRedundancyChassisLICType OBJECT-TYPE
SYNTAX INTEGER { lc-unknown(1), lc-8020-10GE(3), lc-8064-1GE(4),
lc-8032-1GE(19), lc-8062-1GE(20) }
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"LIC type"
::= { prvtRedundancyChassisEntry 2 }
prvtRedundancyChassisStatus OBJECT-TYPE
SYNTAX INTEGER { protected(0), notProtected(1) }
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Chassis status"
::= { prvtRedundancyChassisEntry 3 }
prvtRedundancyChassisEntryStatus OBJECT-TYPE
SYNTAX INTEGER { extracted(0), inserted(1) }
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Chassis Entry status"
::= { prvtRedundancyChassisEntry 4 }
licStatus NOTIFICATION-TYPE
OBJECTS { prvtRedundancyChassisEntryStatus }
STATUS current
DESCRIPTION
"LIC prvtRedundancyChassisEntryStatus has been changed.
Card slotId is present as a key."
::= { prvtRedundancyNotifications 1 }
switchover NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Switchover has happend - link between Active and Standby HUB is broken."
::= { prvtRedundancyNotifications 2 }
redundancyStatus NOTIFICATION-TYPE
OBJECTS { prvtRedundancyChassisStatus }
STATUS current
DESCRIPTION
"Chassis redundancy-status"
::= { prvtRedundancyNotifications 3 }
END -- end of module PRVT-REDUNDANCY-MIB.
|