+-- ** BATM Advanced Communications.
+-- **
+-- *********************************************************************
+-- ** Filename: PRVT-REDUNDANCY-MIB.mib
+-- ** Project: T-Metro Switches.
+-- ** Purpose: Private MIB
+-- *********************************************************************
+-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
+-- WARNING:
+--
+-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
+--
+-- This file is the property of BATM Advanced Communications and contains
+-- proprietary and confidential information. This file is made
+-- available to authorized BATM customers on the express
+-- condition that neither it, nor any of the information contained
+-- therein, shall be disclosed to third parties or be used for any
+-- purpose other than to replace, modify or upgrade firmware and/or
+-- software components of BATM manufactured equipment within the
+-- authorized customer's network, and that such transfer be
+-- completed in accordance with the instructions provided by
+-- BATM. Any other use is strictly prohibited.
+--
+-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
+-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
+-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
+-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
+-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
+--
+-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
+-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
+-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
+-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
+-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
+--
+-- ----------------------------------------------------------------------------
+
+PRVT-REDUNDANCY-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ software
+ FROM PRVT-SWITCH-MIB
+ MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, Unsigned32
+ FROM SNMPv2-SMI;
+
+prvtRedundancyMIB MODULE-IDENTITY
+ LAST-UPDATED "201312170000Z"
+ ORGANIZATION
+ "BATM Advanced Communication"
+ CONTACT-INFO
+ "BATM/Telco Systems Support team
+ Email:
+ For North America: techsupport@telco.com
+ For North Europe: support@batm.de, info@batm.de
+ For the rest of the world: techsupport@telco.com"
+ DESCRIPTION
+ "Monitoring of components redundancy protection"
+ REVISION "201312170000Z"
+ DESCRIPTION
+ "Initial version."
+ ::= { software 5 }
+
+
+prvtRedundancyNotifications OBJECT IDENTIFIER
+ ::= { prvtRedundancyMIB 0 }
+
+prvtRedundancyObjects OBJECT IDENTIFIER
+ ::= { prvtRedundancyMIB 1 }
+
+prvtRedundancyChassisTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PrvtRedundancyChassisEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of slots in the chassis"
+ ::= { prvtRedundancyObjects 1 }
+
+prvtRedundancyChassisEntry OBJECT-TYPE
+ SYNTAX PrvtRedundancyChassisEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in prvtRedundancyChassisTable"
+ INDEX { prvtRedundancyChassisSlotId }
+ ::= { prvtRedundancyChassisTable 1 }
+
+PrvtRedundancyChassisEntry ::= SEQUENCE {
+ prvtRedundancyChassisSlotId Unsigned32,
+ prvtRedundancyChassisLICType INTEGER,
+ prvtRedundancyChassisStatus INTEGER,
+ prvtRedundancyChassisEntryStatus INTEGER
+}
+
+prvtRedundancyChassisSlotId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index in the table."
+ ::= { prvtRedundancyChassisEntry 1 }
+
+prvtRedundancyChassisLICType OBJECT-TYPE
+ SYNTAX INTEGER { lc-unknown(1), lc-8020-10GE(3), lc-8064-1GE(4),
+ lc-8032-1GE(19), lc-8062-1GE(20) }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "LIC type"
+ ::= { prvtRedundancyChassisEntry 2 }
+
+prvtRedundancyChassisStatus OBJECT-TYPE
+ SYNTAX INTEGER { protected(0), notProtected(1) }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Chassis status"
+ ::= { prvtRedundancyChassisEntry 3 }
+
+prvtRedundancyChassisEntryStatus OBJECT-TYPE
+ SYNTAX INTEGER { extracted(0), inserted(1) }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Chassis Entry status"
+ ::= { prvtRedundancyChassisEntry 4 }
+
+licStatus NOTIFICATION-TYPE
+ OBJECTS { prvtRedundancyChassisEntryStatus }
+ STATUS current
+ DESCRIPTION
+ "LIC prvtRedundancyChassisEntryStatus has been changed.
+ Card slotId is present as a key."
+ ::= { prvtRedundancyNotifications 1 }
+
+switchover NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Switchover has happend - link between Active and Standby HUB is broken."
+ ::= { prvtRedundancyNotifications 2 }
+
+redundancyStatus NOTIFICATION-TYPE
+ OBJECTS { prvtRedundancyChassisStatus }
+ STATUS current
+ DESCRIPTION
+ "Chassis redundancy-status"
+ ::= { prvtRedundancyNotifications 3 }
+
+END -- end of module PRVT-REDUNDANCY-MIB.