summaryrefslogtreecommitdiff
path: root/MIBS/siae/SIAE-MANOP-MIB
blob: c89ad4aeaecb5c9b32ed1bb26300d04fee63c498 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
-- ----------------------------------------------------------------------------
--
--  SIAE MICROELETTRONICA s.p.a.
--                 
--  Via Michelangelo Buonarroti, 21
--  20093 - Cologno Monzese
--  Milano 
--  ITALY
--
-- ----------------------------------------------------------------------------
-- ----------------------------------------------------------------------------

SIAE-MANOP-MIB
        DEFINITIONS ::= BEGIN

        IMPORTS
             MODULE-IDENTITY, OBJECT-TYPE,
             Integer32, Unsigned32
        FROM SNMPv2-SMI
             siaeMib
        FROM SIAE-TREE-MIB
             AlarmStatus, AlarmSeverityCode
        FROM SIAE-ALARM-MIB;
           
    manualOperation MODULE-IDENTITY
        LAST-UPDATED "201403170000Z"
        ORGANIZATION "SIAE MICROELETTRONICA spa"
        CONTACT-INFO
            "SIAE MICROELETTONICA s.p.a.
             Via Michelangelo Buonarroti, 21
             20093 - Cologno Monzese
             Milano - ITALY
             Phone :  +39-02-27325-1
             E-mail: tbd@siaemic.com
            "
        DESCRIPTION
            "Manual Operation management.
            "
        REVISION "201403170000Z"
        DESCRIPTION
            "Fixed DESCRIPTION of manualOpActiveSeverityCode
            "
        REVISION "201402030000Z"
        DESCRIPTION
            "Improved description of manualOpMibVersion
            "
        REVISION "201304160000Z"
        DESCRIPTION 
            "Initial version 01.00.00
            "
    ::= { siaeMib 71 }

----------------------------------------------------------------------------------
--  object identifier inside the module
----------------------------------------------------------------------------------

    manualOpTrap OBJECT IDENTIFIER ::= { manualOperation 0 }

----------------------------------------------------------------------------------
--  SIAE manualOperation GROUP
----------------------------------------------------------------------------------
--
--  The following listed objects are general object common to all SIAE equipment.
--
----------------------------------------------------------------------------------

------ Beginning --------------------------------------------------------------


    manualOpMibVersion  OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Numerical version of this module.
             The string version of this MIB have the following format:
                XX.YY.ZZ
             so, for example, the value 1 should be interpreted as 00.00.01
             and the value 10001 should be interpreted as 01.00.01."
        DEFVAL {1}
    ::= {manualOperation 1}

-------  Begin of equipManOpTable
--
    manualOpTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF ManualOpRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table with manual operation record."
    ::= {manualOperation 2}

    manualOpRecord  OBJECT-TYPE
        SYNTAX      ManualOpRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Manual operation record."
        INDEX {manualOpId}
    ::= {manualOpTable 1}

    ManualOpRecord  ::=
        SEQUENCE {
            manualOpId          Integer32,
            manualOpObjectId    OBJECT IDENTIFIER,
            manualOpEventTime   Unsigned32,
            manualOpValueType   INTEGER,
            manualOpIntegerVal  Integer32,
            manualOpOidVal      OBJECT IDENTIFIER
        }

    manualOpId  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Manual operation index."
    ::= {manualOpRecord 1}

    manualOpObjectId  OBJECT-TYPE
        SYNTAX      OBJECT IDENTIFIER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Object identifier of the manual operation active element."
    ::= {manualOpRecord 2}

    manualOpEventTime  OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The time (in seconds since 01-Gen-1970) when the event was 
             registered in the table."
    ::= {manualOpRecord 3}

    manualOpValueType  OBJECT-TYPE
        SYNTAX      INTEGER {
                              integer32  (1),
                              objectId   (2)
                            }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The type of the value. One and only one of the value object
             that follow is used for a given row in this table, based on
             this type."
    ::= {manualOpRecord 4}

    manualOpIntegerVal  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The value when manualOpValueType is 'integer32'."
    ::= {manualOpRecord 5}

    manualOpOidVal  OBJECT-TYPE
        SYNTAX      OBJECT IDENTIFIER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The value when manualOpValueType is 'objectId'."
    ::= {manualOpRecord 6}

--
-------  End of equipManOpTable

    manualOpActive  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Manual Operation active on the equipment."
    ::= {manualOperation 3}

    manualOpActiveSeverityCode  OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Defines the severity associated to manualOpActive  
             and enables/disables the trap generation on status change event."
        DEFVAL {warningTrapEnable}
    ::= {manualOperation 4}

    manualOpTimeOut  OBJECT-TYPE
        SYNTAX      INTEGER    (0..172800)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object defines the time (in seconds) after wich the manual
             operations are cleared. The maximum value is equivalent to 48 hours.
             A zero means no Time-out."
        DEFVAL {2}
    ::= {manualOperation 5}

------ End group -------------------------------------------------------------