+-- SIAE MICROELETTRONICA s.p.a.
+--
+-- Via Michelangelo Buonarroti, 21
+-- 20093 - Cologno Monzese
+-- Milano
+-- ITALY
+--
+-- ----------------------------------------------------------------------------
+-- ----------------------------------------------------------------------------
+
+SIAE-MANOP-MIB
+ DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE,
+ Integer32, Unsigned32
+ FROM SNMPv2-SMI
+ siaeMib
+ FROM SIAE-TREE-MIB
+ AlarmStatus, AlarmSeverityCode
+ FROM SIAE-ALARM-MIB;
+
+ manualOperation MODULE-IDENTITY
+ LAST-UPDATED "201403170000Z"
+ ORGANIZATION "SIAE MICROELETTRONICA spa"
+ CONTACT-INFO
+ "SIAE MICROELETTONICA s.p.a.
+ Via Michelangelo Buonarroti, 21
+ 20093 - Cologno Monzese
+ Milano - ITALY
+ Phone : +39-02-27325-1
+ E-mail: tbd@siaemic.com
+ "
+ DESCRIPTION
+ "Manual Operation management.
+ "
+ REVISION "201403170000Z"
+ DESCRIPTION
+ "Fixed DESCRIPTION of manualOpActiveSeverityCode
+ "
+ REVISION "201402030000Z"
+ DESCRIPTION
+ "Improved description of manualOpMibVersion
+ "
+ REVISION "201304160000Z"
+ DESCRIPTION
+ "Initial version 01.00.00
+ "
+ ::= { siaeMib 71 }
+
+----------------------------------------------------------------------------------
+-- object identifier inside the module
+----------------------------------------------------------------------------------
+
+ manualOpTrap OBJECT IDENTIFIER ::= { manualOperation 0 }
+
+----------------------------------------------------------------------------------
+-- SIAE manualOperation GROUP
+----------------------------------------------------------------------------------
+--
+-- The following listed objects are general object common to all SIAE equipment.
+--
+----------------------------------------------------------------------------------
+
+------ Beginning --------------------------------------------------------------
+
+
+ manualOpMibVersion OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Numerical version of this module.
+ The string version of this MIB have the following format:
+ XX.YY.ZZ
+ so, for example, the value 1 should be interpreted as 00.00.01
+ and the value 10001 should be interpreted as 01.00.01."
+ DEFVAL {1}
+ ::= {manualOperation 1}
+
+------- Begin of equipManOpTable
+--
+ manualOpTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ManualOpRecord
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with manual operation record."
+ ::= {manualOperation 2}
+
+ manualOpRecord OBJECT-TYPE
+ SYNTAX ManualOpRecord
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Manual operation record."
+ INDEX {manualOpId}
+ ::= {manualOpTable 1}
+
+ ManualOpRecord ::=
+ SEQUENCE {
+ manualOpId Integer32,
+ manualOpObjectId OBJECT IDENTIFIER,
+ manualOpEventTime Unsigned32,
+ manualOpValueType INTEGER,
+ manualOpIntegerVal Integer32,
+ manualOpOidVal OBJECT IDENTIFIER
+ }
+
+ manualOpId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Manual operation index."
+ ::= {manualOpRecord 1}
+
+ manualOpObjectId OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Object identifier of the manual operation active element."
+ ::= {manualOpRecord 2}
+
+ manualOpEventTime OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time (in seconds since 01-Gen-1970) when the event was
+ registered in the table."
+ ::= {manualOpRecord 3}
+
+ manualOpValueType OBJECT-TYPE
+ SYNTAX INTEGER {
+ integer32 (1),
+ objectId (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of the value. One and only one of the value object
+ that follow is used for a given row in this table, based on
+ this type."
+ ::= {manualOpRecord 4}
+
+ manualOpIntegerVal OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when manualOpValueType is 'integer32'."
+ ::= {manualOpRecord 5}
+
+ manualOpOidVal OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when manualOpValueType is 'objectId'."
+ ::= {manualOpRecord 6}
+
+--
+------- End of equipManOpTable
+
+ manualOpActive OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Manual Operation active on the equipment."
+ ::= {manualOperation 3}
+
+ manualOpActiveSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the severity associated to manualOpActive
+ and enables/disables the trap generation on status change event."
+ DEFVAL {warningTrapEnable}
+ ::= {manualOperation 4}
+
+ manualOpTimeOut OBJECT-TYPE
+ SYNTAX INTEGER (0..172800)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object defines the time (in seconds) after wich the manual
+ operations are cleared. The maximum value is equivalent to 48 hours.
+ A zero means no Time-out."
+ DEFVAL {2}
+ ::= {manualOperation 5}
+
+------ End group -------------------------------------------------------------
+