summaryrefslogtreecommitdiff
path: root/MIBS/nokia/ALCATEL-IND1-PORT-MIB
blob: ab32af3684dafd2afa322564c2f24808e803dbae (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
ALCATEL-IND1-PORT-MIB DEFINITIONS ::= BEGIN

IMPORTS
	OBJECT-TYPE, Counter64,
        NOTIFICATION-TYPE, MODULE-IDENTITY,
	TimeTicks, Integer32              FROM SNMPv2-SMI
        MODULE-COMPLIANCE, OBJECT-GROUP,
        NOTIFICATION-GROUP                FROM SNMPv2-CONF
        ifIndex, ifInErrors, ifOutErrors
					  FROM IF-MIB
	softentIND1Port, cmmEsmDrvTraps
			   		  FROM ALCATEL-IND1-BASE
	DisplayString            FROM SNMPv2-TC;

alcatelIND1PortMIB MODULE-IDENTITY

   LAST-UPDATED  "200704030000Z"
   ORGANIZATION  "Alcatel-Lucent"
   CONTACT-INFO
        "Please consult with Customer Service to ensure the most appropriate
         version of this document is used with the products in question:

                    Alcatel-Lucent, Enterprise Solutions Division
                   (Formerly Alcatel Internetworking, Incorporated)
                           26801 West Agoura Road
                        Agoura Hills, CA  91301-5122
                          United States Of America

        Telephone:               North America  +1 800 995 2696
                                 Latin America  +1 877 919 9526
                                 Europe         +31 23 556 0100
                                 Asia           +65 394 7933
                                 All Other      +1 818 878 4507

        Electronic Mail:         support@ind.alcatel.com
        World Wide Web:          http://alcatel-lucent.com/wps/portal/enterprise
        File Transfer Protocol:  ftp://ftp.ind.alcatel.com/pub/products/mibs"

    DESCRIPTION
        "This module describes an authoritative enterprise-specific Simple
         Network Management Protocol (SNMP) Management Information Base (MIB):

             This group contains the configuration information data
			for the Ethernet Switching Module.

         The right to make changes in specification and other information
         contained in this document without prior notice is reserved.

         No liability shall be assumed for any incidental, indirect, special, or
         consequential damages whatsoever arising from or related to this
         document or the information contained herein.

         Vendors, end-users, and other interested parties are granted
         non-exclusive license to use this specification in connection with
         management of the products for which it is intended to be used.

                     Copyright (C) 1995-2007 Alcatel-Lucent
                         ALL RIGHTS RESERVED WORLDWIDE"

    REVISION      "200704030000Z"
    DESCRIPTION
        "The latest version of this MIB Module."

    ::= { softentIND1Port 1}

alcatelIND1PortNotifications	OBJECT IDENTIFIER ::= { alcatelIND1PortMIB 0 }
alcatelIND1PortMIBObjects 		OBJECT IDENTIFIER ::= { alcatelIND1PortMIB 1 }
alcatelIND1PortMIBConformance		OBJECT IDENTIFIER ::= { alcatelIND1PortMIB 2 }

--
-- alcatelIND1PortMIBObjects
--

esmConfTrap						OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 1 }
physicalPort					OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 2 }
ddmConfiguration				OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 4 }
ddmNotifications				OBJECT IDENTIFIER ::= { alcatelIND1PortNotifications 1 }
esmViolationRecovery				OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 5 }
esmViolationNotifications                       OBJECT IDENTIFIER ::= { alcatelIND1PortNotifications 2 } 

-- Ethernet Driver object related to Trap *********************

esmDrvTrapDrops   OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION "Partitioned port (separated due to errors)."
	::= { esmConfTrap 1 }

-- Ethernet Driver Tables *****************************

        --  EsmConf group.  This group contains the configuration
        --  information data for the Ethernet Switching Module.
        --  Implementation of this group is mandantory.
        --
        --  Note that this MIB can NOT be used for row creation (this
        --  would imply that you could override the actual physical
        --  characteristics of the physical card!).

        esmConfTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF EsmConfEntry
            MAX-ACCESS  not-accessible
            STATUS  current
            DESCRIPTION
                "A list of ESM Physical Port instances."
            ::= { physicalPort 1 }

        esmConfEntry  OBJECT-TYPE
            SYNTAX  EsmConfEntry
            MAX-ACCESS  not-accessible
            STATUS  current
            DESCRIPTION
                "A ESM Physical Port entry."
            INDEX { ifIndex }
            ::= { esmConfTable 1 }

        EsmConfEntry ::= SEQUENCE {
	    esmPortSlot
	        Integer32,
	    esmPortIF
	        Integer32,
            esmPortAutoSpeed
                INTEGER,
            esmPortAutoDuplexMode
                INTEGER,
            esmPortCfgSpeed
                INTEGER,
            esmPortCfgDuplexMode
                INTEGER,
            esmPortCfgIFG
                Integer32,
            esmPortPauseSlotTime
                Integer32,
            esmPortMaxFloodRate
                INTEGER,
            esmPortFloodMcastEnable
                INTEGER,
            esmPortCfgMaxFrameSize
                Integer32,
            esmPortCfgLongEnable
                INTEGER,
            esmPortCfgRuntEnable
                INTEGER,
            esmPortCfgRuntSize
                Integer32,
	    esmPortCfgAutoNegotiation
			INTEGER,
	    esmPortCfgCrossover
			INTEGER,
	    esmPortCfgFlow
			INTEGER,
	    esmPortCfgHybridActiveType
	    		INTEGER,
	    esmPortCfgHybridMode
	    		INTEGER,
            esmPortOperationalHybridType
                        INTEGER,
            esmPortCfgMMULowWaterMarkCellSetLimit
                	INTEGER,
            esmPortCfgMMUDynamicCellSetLimit
                	INTEGER,
            esmPortViolationBitMap
                        BITS,
            esmPortViolationClearAll
                        INTEGER,
	    esmPortFloodBcastEnable
		INTEGER,
	    esmPortFloodUnknownUcastEnable
		INTEGER,
	    esmPortMaxUnknownUcastFloodRate
		INTEGER,
	    esmPortMaxMcastFloodRate
		INTEGER,
	    esmPortMaxFloodRateLimit
		Integer32,
	    esmPortMaxUnknownUcastFloodRateLimit
		Integer32,
	    esmPortMaxMcastFloodRateLimit
		Integer32,
	    esmPortCfgSFPType
		DisplayString 
            }

        esmPortSlot OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
            "The physical Slot number for this Ethernet Port.
	     Slot number has been added to be used by the private Trap."
        ::= { esmConfEntry 1 }

        esmPortIF OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
            "The on-board interface number for this Ethernet Port.
	     Port Number has been added to be used by the private Trap."
        ::= { esmConfEntry 2 }

        esmPortAutoSpeed OBJECT-TYPE
            SYNTAX INTEGER {
                speed100(1),
                speed10(2),
                speedAuto(3),
                unknown(4),
                speed1000(5),
	        speed10000(6)
            }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
            "The automatically detected port line speed
             of this ESM port."
        ::= { esmConfEntry 3 }

        esmPortAutoDuplexMode OBJECT-TYPE
            SYNTAX INTEGER {
                fullDuplex(1),
                halfDuplex(2),
                autoDuplex(3),
                unknown(4)
            }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
            "The automatically detected port duplex mode
             of this ESM port.

	     Note: GigaEthernet supports only Full duplex mode.
	           Default value for 10/100 = Half duplex mode."
        ::= { esmConfEntry 4 }

        esmPortCfgSpeed OBJECT-TYPE
            SYNTAX INTEGER {
                speed100(1),
                speed10(2),
                speedAuto(3),
                speed1000(5),
	        speed10000(6),
	        speedMax100(8),
		speedMax1000(9)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
            "The configured port line speed of this ESM port."
        ::= { esmConfEntry 5 }

        esmPortCfgDuplexMode OBJECT-TYPE
            SYNTAX INTEGER {
                fullDuplex(1),
                halfDuplex(2),
                autoDuplex(3)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
            "The configured port duplex mode of this ESM port.
            Note: GigaEthernet support only full-duplex."
        ::= { esmConfEntry 6 }

        esmPortCfgIFG OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
            "Contains the setting of Inter-Frame Gap (IFG), in bytes
            for receive and transmit.
	    The range is from 9 to 12 bytes.

	    Note: The default value changed according to the Port type
	    Default    Bandwidth    value
	    12 bytes    10Mbps       9600 nsec
	               100Mbps        960 nsec
	 	         1Gbps         96 nsec
			10Gbps        9.6 nsec."
	    DEFVAL { 12 }
        ::= { esmConfEntry 7 }

        esmPortPauseSlotTime OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
            "Indicates the number of microseconds the other
             end-station waits after the reception
             of a pause frame.

	     Note: Pause Flow control is not available for 10Mbps.
	           For 100Mbps, the possible value range is
		   5120 nanosec to 0.3 sec.
	   	   For 1Gbps, the possible value range is
		   512 nanosec to 0.03 sec."
        ::= { esmConfEntry 8 }

        esmPortMaxFloodRate    OBJECT-TYPE
            SYNTAX INTEGER {
                      mbps(1),
                      percentage(2),
		      pps(3)
                   }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Broadcast flood threshold type. To set the type, set esmPortMaxFloodRateLimit also."
	    DEFVAL { mbps }
          ::= { esmConfEntry 9 }

        esmPortFloodMcastEnable    OBJECT-TYPE
            SYNTAX INTEGER {
                      disableMulticastFlood(2),
                      enableMulticastFlood(1)
                   }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Enable/disable the maximum flood rate
                  for multicast."
	    DEFVAL { disableMulticastFlood }
          ::= { esmConfEntry 10 }

        esmPortCfgMaxFrameSize   OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Configure the value of the maximum frame
                  size allow.
		  For 10/100:
		  It is a range between 1518(untagged) and 1553 bytes.
		  For GigaEthernet:
	          It is a range between 1518 and 10240 bytes.(OS7700,OS7800,OS8800)
                  It is a range between 1518 and 9216 bytes.(OS6800)"
          ::= { esmConfEntry 11 }

        esmPortCfgLongEnable   OBJECT-TYPE
            SYNTAX INTEGER {
                disable(0),
                enable(1)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Allow the user to change the maximun Frame size.
                  Note: It is not configurable for 10/100 Ethernet port."
	    DEFVAL { disable }
          ::= { esmConfEntry 12 }

        esmPortCfgRuntEnable   OBJECT-TYPE
            SYNTAX INTEGER {
                disable(2),
                enable(3)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Allow the user to change the minimum Frame size."
	    DEFVAL { disable }
          ::= { esmConfEntry 13 }

        esmPortCfgRuntSize   OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Configure the value of the minimum frame
                  size allow per ports.
		  The range is 0 to 64."
	    DEFVAL { 64 }
          ::= { esmConfEntry 14 }

        esmPortCfgAutoNegotiation   OBJECT-TYPE
            SYNTAX INTEGER {
                enable(1),
                disable(2)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Allow the user to enable or disable the port auto negotiation."
	    DEFVAL { disable }
          ::= { esmConfEntry 15 }

        esmPortCfgCrossover   OBJECT-TYPE
            SYNTAX INTEGER {
                	mdi(1),
                	mdix(2),
			auto(3)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Allow the user to configure port crossover."
	    DEFVAL { auto }
          ::= { esmConfEntry 16 }

        esmPortCfgFlow   OBJECT-TYPE
            SYNTAX INTEGER {
                enable(1),
                disable(2)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Use the dot3PauseAdminMode from the standard MIB to configure the flow control."
	    DEFVAL { disable }
          ::= { esmConfEntry 17 }

 	esmPortCfgHybridActiveType OBJECT-TYPE
            SYNTAX INTEGER {
                notapplicable(0),
                fiber(1),
                copper(2)
            }
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "This object is only applicable to hybrid ports .
                  It indicates configured active media type.(the operational media
                  type may be different if esmPortCfgHybridMode is configured to be
                  preferredFiber or preferredCopper)
                  For non hybrid ports notapplicable is returned as a status."
          ::= { esmConfEntry 18 }

	esmPortCfgHybridMode OBJECT-TYPE
            SYNTAX INTEGER {
                notapplicable(0),
                preferredCopper(1),
                forcedCopper(2),
                preferredFiber(3),
                forcedFiber(4)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "This object is only applicable to hybrid ports. 
                  This allows the user the user to configure the media type
                  with which the port should come up. 
                  The user can configure the port to come as copper only 
                  or fiber only or either fiber/copper 
                  (with preference to one of them)."
	    DEFVAL { preferredFiber }
          ::= { esmConfEntry 19 }

 	esmPortOperationalHybridType OBJECT-TYPE
            SYNTAX INTEGER {
		none(0),
                fiber(1),
                copper(2)
            }
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "This object is only applicable to hybrid ports .
                  It indicates  the actual media type that has link up and is or will be
                  passing traffic. If link is not present the object will return none(0) value."
          ::= { esmConfEntry 20 }

	esmPortCfgMMULowWaterMarkCellSetLimit OBJECT-TYPE
	    SYNTAX INTEGER (0..16383)
	    MAX-ACCESS read-write
	    STATUS current
	    DESCRIPTION
		" Per-port-per-CoS Head of Line blocking cell limits. Range is 0 - 16383
		  Firebolt register Offset: 0x006pp30 - 0x37
		  Bits: 13:0 CellSetLimit , Default: 0x0100
		  This setting allocates the guaranteed cells for one port's CoSx queue.
		  After cell count over this limit, it will start using dynamic cells in
		  port dynamic space."
	    DEFVAL { 256 }
	  ::= { esmConfEntry 21 }

	esmPortCfgMMUDynamicCellSetLimit OBJECT-TYPE
	    SYNTAX INTEGER (0..16383)
	    MAX-ACCESS read-write
	    STATUS current
	    DESCRIPTION
		"Per-egress port cell-based dynamic (shared buffer pool) memory
		usage drop and resume thresholds. This sets the limit for which
		the eight CoS-Qs within a port may share once the LWMCOSCELL
		limit is exceeded. Range is 0 - 16383
		Firebolt register Offset: 0x006pp040
		Bits: 13:0 Dynamic CellSetLimit , 
                Chip Default: 0x0400 (1024).
                The system default value for Dynamic CellSetLimit is 0x100 (256)."
	    DEFVAL { 1024 }
	  ::= { esmConfEntry 22 }



	esmPortViolationBitMap OBJECT-TYPE
          SYNTAX      BITS{
              bEniSecurityBlockPortENI(0),         -- ENI App blocking this port
              bEniSecurityBlockPortSTP(1),         -- STP App blocking this port
 	      bEniSecurityBlockPortSL(2),          -- SL App blocking this port
	      bEniSecurityBlockPortQoS(3),         -- QoS App blocking this port
 	      bEniSecurityBlockPortUDLD(4),        -- UDLD App blocking this port
	      bEniSecurityBlockPortETHBLK(5)       -- ETHBLK App blocking this port
          }
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION "A bit map that identifies the set of Application that have blocked 
                       a port as a result of a particular violation "

          ::= { esmConfEntry 23 }

      esmPortViolationClearAll OBJECT-TYPE
          SYNTAX      INTEGER(0) 
          MAX-ACCESS  read-write
          STATUS      current
          DESCRIPTION "Clear all port vioaltion "

          ::= { esmConfEntry 24 }


	esmPortFloodBcastEnable    OBJECT-TYPE
            SYNTAX INTEGER {
                      disableBcastFlood(2),
                      enableBcastFlood(1)
                   }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Enable/disable the maximum flood rate
                  for Broadcast."
	    DEFVAL { enableBcastFlood }
          ::= { esmConfEntry 25 }

	esmPortFloodUnknownUcastEnable    OBJECT-TYPE
            SYNTAX INTEGER {
                      disableUnknownUcastFlood(2),
                      enableUnknownUcastFlood(1)
                   }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Enable/disable the maximum flood rate
                  for unknown unicast."
	    DEFVAL { enableUnknownUcastFlood }
          ::= { esmConfEntry 26 }

	esmPortMaxUnknownUcastFloodRate    OBJECT-TYPE
            SYNTAX INTEGER {
                      mbps(1),
                      percentage(2),
		      pps(3)
                   }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Unknown-Unicast flood threshold type. To set the type, set esmPortMaxUnknownUcastFloodRateLimit also"
	    DEFVAL { mbps }
          ::= { esmConfEntry 27 }

	esmPortMaxMcastFloodRate    OBJECT-TYPE
            SYNTAX INTEGER {
                      mbps(1),
                      percentage(2),
		      pps(3)
                   }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Multicast flood threshold type. To set the type, set esmPortMaxFloodRateLimit also."
	    DEFVAL { mbps }
          ::= { esmConfEntry 28 }

	esmPortMaxFloodRateLimit    OBJECT-TYPE
            SYNTAX  Integer32
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "The value of the maximum broadcast flood limit.
		  The actual range of the flood limit depends on the port speed.
		     example:	
		     Percentage: 1 - 100
		     Mbps: 1 - 1000 (1G speed)
		     PPS: 244 - 244262 (1G speed)
		  To set the limit, set esmPortMaxFloodRate first" 
          ::= { esmConfEntry 29 }


	esmPortMaxUnknownUcastFloodRateLimit    OBJECT-TYPE
            SYNTAX  Integer32
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "The value of the maximum unknown-unicast flood limit
		  The actual range of the flood limit depends on the port speed.
		     example:	
		     Percentage: 1 - 100
		     Mbps: 1 - 1000 (1G speed)
		     PPS: 244 - 244262 (1G speed)
		  To set the limit, set esmPortMaxUnknownUcastFloodRate first"
          ::= { esmConfEntry 30 }

       esmPortMaxMcastFloodRateLimit    OBJECT-TYPE
            SYNTAX  Integer32
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "The value of the maximum multicast flood limit
		  The actual range of the flood limit depends on the port speed.
		     example:	
		     Percentage: 1 - 100
		     Mbps: 1 - 1000 (1G speed)
		     PPS: 244 - 244262 (1G speed)
		  To set the limit, set esmPortMaxMcastFloodRate first"
          ::= { esmConfEntry 31 }

       esmPortCfgSFPType OBJECT-TYPE   
            SYNTAX      DisplayString (SIZE (0..64))   
            MAX-ACCESS read-only   
            STATUS      current   
            DESCRIPTION   
                 "This object is only applicable to fiber ports.   
                  The string indicates the type of SFP/GBIC of active media."   
          ::= {  esmConfEntry 32 }  

    

-- Ethernet Port Mode Tables *****************************
        --  EsmPortMode group.  This group contains the configuration
        --  information data for the Ethernet Switching Module.
        --  Implementation of this group is mandantory.
        --
        --  Note that this MIB can NOT be used for row creation (this
        --  would imply that you could override the actual physical
        --  characteristics of the physical card!).

        esmPortModeTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF EsmPortModeEntry
            MAX-ACCESS  not-accessible
            STATUS  current
            DESCRIPTION
                "A list of ESM Physical Port Mode instances."
            ::= { physicalPort 6 }

        esmPortModeEntry  OBJECT-TYPE
            SYNTAX  EsmPortModeEntry
            MAX-ACCESS  not-accessible
            STATUS  current
            DESCRIPTION
                "A ESM Physical Port Mode entry."
            INDEX { esmPortModeIndex }
            ::= { esmPortModeTable 1 }

        EsmPortModeEntry ::= SEQUENCE {
	    esmPortModeIndex
		INTEGER,
            esmPortRunningMode
                INTEGER,
            esmPortSavedMode
                INTEGER
            }

	esmPortModeIndex OBJECT-TYPE
	    SYNTAX INTEGER (1001..8128)
	    MAX-ACCESS not-accessible
	    STATUS current
	    DESCRIPTION
	    "Valid ni/port values"
	::= { esmPortModeEntry 1 }

        esmPortRunningMode OBJECT-TYPE
            SYNTAX INTEGER {
                uplink(1),
                stackable(2)
            }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
            "Currently configured Etna port 25,26 as 10G uplink user port or stacking port.
             Default is uplink 10G port. User can not set the current mode."
        ::= { esmPortModeEntry 2 }

        esmPortSavedMode OBJECT-TYPE
            SYNTAX INTEGER {
                uplink(1),
                stackable(2)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
            "Next configured Etna port 25,26 as 10G uplink user port or stacking port.
             At boot up, it has the same value as current esmPortRunningMode. It takes some time to
             write to the EEPROM. Have at least more than 7 sec between each write operation"
        ::= { esmPortModeEntry 3 }

          -- The Ethernet Statistics Group
          --
          -- The ethernet statistics group contains statistics
          -- measured by the probe for each monitored interface on
          -- this device.  These statistics take the form of free
          -- running counters that start from zero when a valid entry
          -- is created.
          --
          -- This group currently has statistics defined only for
          -- Ethernet interfaces.  Each alcetherStatsEntry contains
          -- statistics for one Ethernet interface.  The probe must
          -- create one alcetherStats entry for each monitored Ethernet
          -- interface on the device.

          alcetherStatsTable OBJECT-TYPE
              SYNTAX SEQUENCE OF AlcetherStatsEntry
              MAX-ACCESS not-accessible
              STATUS current
              DESCRIPTION
                  "A list of Ethernet statistics entries."
              ::= { physicalPort 2 }

          alcetherStatsEntry OBJECT-TYPE
              SYNTAX AlcetherStatsEntry
              MAX-ACCESS not-accessible
              STATUS current
              DESCRIPTION
                  "A collection of statistics kept for a particular
                  Ethernet interface.  As an example, an instance of the
                  etherStatsPkts object might be named alcetherStatsPkts.1"
              INDEX { ifIndex }
              ::= { alcetherStatsTable 1 }

          AlcetherStatsEntry ::= SEQUENCE {
	      alcetherClearStats		    INTEGER,
	      alcetherLastClearStats                TimeTicks,
              alcetherStatsCRCAlignErrors           Counter64,
              alcetherStatsRxUndersizePkts          Counter64,
              alcetherStatsTxUndersizePkts          Counter64,
              alcetherStatsTxOversizePkts           Counter64,
              alcetherStatsRxJabbers                Counter64,
              alcetherStatsRxCollisions             Counter64,
              alcetherStatsTxCollisions             Counter64,
              alcetherStatsPkts64Octets             Counter64,
              alcetherStatsPkts65to127Octets        Counter64,
              alcetherStatsPkts128to255Octets       Counter64,
              alcetherStatsPkts256to511Octets       Counter64,
              alcetherStatsPkts512to1023Octets      Counter64,
              alcetherStatsPkts1024to1518Octets     Counter64,
              gigaEtherStatsPkts1519to4095Octets    Counter64,
              gigaEtherStatsPkts4096to9215Octets    Counter64,
		alcetherStatsPkts1519to2047Octets 	Counter64,
		alcetherStatsPkts2048to4095Octets 	Counter64,
		alcetherStatsPkts4096Octets 		Counter64,
		alcetherStatsRxGiantPkts 		Counter64,
		alcetherStatsRxDribbleNibblePkts 	Counter64,
		alcetherStatsRxLongEventPkts 		Counter64,
		alcetherStatsRxVlanTagPkts 		Counter64,
		alcetherStatsRxControlPkts 		Counter64,
		alcetherStatsRxLenChkErrPkts 		Counter64,
		alcetherStatsRxCodeErrPkts 		Counter64,
		alcetherStatsRxDvEventPkts 		Counter64,
		alcetherStatsRxPrevPktDropped 	Counter64,
		alcetherStatsTx64Octets 		Counter64,
		alcetherStatsTx65to127Octets 		Counter64,
		alcetherStatsTx128to255Octets 	Counter64,
		alcetherStatsTx256to511Octets 	Counter64,
		alcetherStatsTx512to1023Octets 	Counter64,
		alcetherStatsTx1024to1518Octets 	Counter64,
		alcetherStatsTx1519to2047Octets 	Counter64,
		alcetherStatsTx2048to4095Octets 	Counter64,
		alcetherStatsTx4096Octets 		Counter64,
		alcetherStatsTxRetryCount 		Counter64,
		alcetherStatsTxVlanTagPkts 		Counter64,
		alcetherStatsTxControlPkts 		Counter64,
		alcetherStatsTxLatePkts 		Counter64,
		alcetherStatsTxTotalBytesOnWire 	Counter64,
		alcetherStatsTxLenChkErrPkts 		Counter64,
		alcetherStatsTxExcDeferPkts		Counter64
		}

          alcetherClearStats OBJECT-TYPE
              SYNTAX INTEGER
		{	default(0),
	 		reset(1)
		}
              MAX-ACCESS read-write
              STATUS current
              DESCRIPTION
                  "Used to Clear all Statistics counters.
		   By default, this object contains zero value."
              ::= { alcetherStatsEntry 1 }

          alcetherLastClearStats OBJECT-TYPE
              SYNTAX TimeTicks
	      MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The value of SysUpTime at the time of all
		   the statistics counters are cleared.
		   By default, this object contains a zero value."
              ::= { alcetherStatsEntry 2 }

          alcetherStatsCRCAlignErrors OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets received that
                  had a length (excluding framing bits, but
                  including FCS octets) of between 64 and 1518
                  octets, inclusive, but but had either a bad
                  Frame Check Sequence (FCS) with an integral
                  number of octets (FCS Error) or a bad FCS with
                  a non-integral number of octets (Alignment Error)."
              ::= { alcetherStatsEntry 3 }

          alcetherStatsRxUndersizePkts OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets received that were
                  less than 64 octets long (excluding framing bits,
                  but including FCS octets) and were otherwise well
                  formed."
              ::= { alcetherStatsEntry 4 }

          alcetherStatsTxUndersizePkts OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets transmitted that were
                  less than 64 octets long (excluding framing bits,
                  but including FCS octets) and were otherwise well
                  formed."
              ::= { alcetherStatsEntry 5 }

          alcetherStatsTxOversizePkts OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets transmitted that were
                  longer than 1518 octets long (excluding framing bits,
                  but including FCS octets) and were otherwise well
                  formed."
              ::= { alcetherStatsEntry 6 }

          alcetherStatsRxJabbers OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets received that were
                  longer than 1518 octets (excluding framing bits,
                  but including FCS octets), and had either a bad
                  Frame Check Sequence (FCS) with an integral number
                  of octets (FCS Error) or a bad FCS with a
                  non-integral number of octets (Alignment Error).

                  Note that this definition of jabber is different
                  than the definition in IEEE-802.3 section 8.2.1.5
                  (10BASE5) and section 10.3.1.4 (10BASE2).  These
                  documents define jabber as the condition where any
                  packet exceeds 20 ms.  The allowed range to detect
                  jabber is between 20 ms and 150 ms."
              ::= { alcetherStatsEntry 7 }

          alcetherStatsRxCollisions OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The best estimate of the total number of collisions
                  on this Ethernet segment (in reception).
		  Only for Ethernet Interfaces.

                  The value returned will depend on the location of
                  the RMON probe. Section 8.2.1.3 (10BASE-5) and
                  section 10.3.1.3 (10BASE-2) of IEEE standard 802.3
                  states that a station must detect a collision, in
                  the receive mode, if three or more stations are
                  transmitting simultaneously.  A repeater port must
                  detect a collision when two or more stations are
                  transmitting simultaneously.  Thus a probe placed on
                  a repeater port could record more collisions than a
                  probe connected to a station on the same segment
                  would.

                  Probe location plays a much smaller role when
                  considering 10BASE-T.  14.2.1.4 (10BASE-T) of IEEE
                  standard 802.3 defines a collision as the
                  simultaneous presence of signals on the DO and RD
                  circuits (transmitting and receiving at the same
                  time).  A 10BASE-T station can only detect
                  collisions when it is transmitting.  Thus probes
                  placed on a station and a repeater, should report
                  the same number of collisions.

                  Note also that an RMON probe inside a repeater
                  should ideally report collisions between the
                  repeater and one or more other hosts (transmit
                  collisions as defined by IEEE 802.3k) plus receiver
                  collisions observed on any coax segments to which
                  the repeater is connected."
              ::= { alcetherStatsEntry 8 }

          alcetherStatsTxCollisions OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The best estimate of the total number of collisions
                  on this Ethernet segment (in transmition).
		  Only for Ethernet Interfaces.

                  The value returned will depend on the location of
                  the RMON probe. Section 8.2.1.3 (10BASE-5) and
                  section 10.3.1.3 (10BASE-2) of IEEE standard 802.3
                  states that a station must detect a collision, in
                  the receive mode, if three or more stations are
                  transmitting simultaneously.  A repeater port must
                  detect a collision when two or more stations are
                  transmitting simultaneously.  Thus a probe placed on
                  a repeater port could record more collisions than a
                  probe connected to a station on the same segment
                  would.

                  Probe location plays a much smaller role when
                  considering 10BASE-T.  14.2.1.4 (10BASE-T) of IEEE
                  standard 802.3 defines a collision as the
                  simultaneous presence of signals on the DO and RD
                  circuits (transmitting and receiving at the same
                  time).  A 10BASE-T station can only detect
                  collisions when it is transmitting.  Thus probes
                  placed on a station and a repeater, should report
                  the same number of collisions.

                  Note also that an RMON probe inside a repeater
                  should ideally report collisions between the
                  repeater and one or more other hosts (transmit
                  collisions as defined by IEEE 802.3k) plus receiver
                  collisions observed on any coax segments to which
                  the repeater is connected."
              ::= { alcetherStatsEntry 9 }

          alcetherStatsPkts64Octets OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets (including bad
                  packets) received that were 64 octets in length
                  (excluding framing bits but including FCS octets)."
              ::= { alcetherStatsEntry 10 }

          alcetherStatsPkts65to127Octets OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets (including bad
                  packets) received that were between
                  65 and 127 octets in length inclusive
                  (excluding framing bits but including FCS octets)."
              ::= { alcetherStatsEntry 11 }

          alcetherStatsPkts128to255Octets OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets (including bad
                  packets) received that were between
                  128 and 255 octets in length inclusive
                  (excluding framing bits but including FCS octets)."
              ::= { alcetherStatsEntry 12 }

          alcetherStatsPkts256to511Octets OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets (including bad
                  packets) received that were between
                  256 and 511 octets in length inclusive
                  (excluding framing bits but including FCS octets)."
              ::= { alcetherStatsEntry 13 }

          alcetherStatsPkts512to1023Octets OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets (including bad
                  packets) received that were between
                  512 and 1023 octets in length inclusive
                  (excluding framing bits but including FCS octets)."
              ::= { alcetherStatsEntry 14 }

          alcetherStatsPkts1024to1518Octets OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets (including bad
                  packets) received that were between
                  1024 and 1518 octets in length inclusive
                  (excluding framing bits but including FCS octets).
	          For both Ethernet and GigaEthernet."
              ::= { alcetherStatsEntry 15 }

          gigaEtherStatsPkts1519to4095Octets OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets (including bad
                  packets) received that were between
                  1519 and 4095 octets in length inclusive
                  (excluding framing bits but including FCS octets).
		  Only for GigaEthernet interfaces"
              ::= { alcetherStatsEntry 16 }

          gigaEtherStatsPkts4096to9215Octets OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets (including bad
                  packets) received that were between
                  4096 and 9215 octets in length inclusive
                  (excluding framing bits but including FCS octets).
		  Only for GigaEthernet interfaces"
              ::= { alcetherStatsEntry 17 }


		alcetherStatsPkts1519to2047Octets 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames(including error packets) received
		   that were between 1519 and 2047 bytes in length inclusive
		   (excluding framing bits but including FCS bytes).
		   "
              ::= { alcetherStatsEntry 18 }

		alcetherStatsPkts2048to4095Octets 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames(including error packets) received
		   that were between 2048 and 4095 bytes in length inclusive
		   (excluding framing bits but including FCS bytes).
		   "
              ::= { alcetherStatsEntry 19 }

		alcetherStatsPkts4096Octets 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames(including error packets) received
		   that were greater than or equal to 4096 bytes in length inclusive
		   (excluding framing bits but including FCS bytes).
		   "
              ::= { alcetherStatsEntry 20 }

		alcetherStatsRxGiantPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames that are greater than the specified
		   Max length value, with a valid CRC, dropped because too long.
		   "
              ::= { alcetherStatsEntry 21 }

		alcetherStatsRxDribbleNibblePkts 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames for which a dribble nibble has been
		   received and CRC is correct.
		   "
              ::= { alcetherStatsEntry 22 }

		alcetherStatsRxLongEventPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames for which the Carrier sense exceeds
		   50000 bit times for 10 Mbits/sec or 80000 bit times for
		   100 Mbits/sec."
              ::= { alcetherStatsEntry 23 }

		alcetherStatsRxVlanTagPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames for which Type/Length field
		   contains the VLAN protocol identifier (0x8100). "
              ::= { alcetherStatsEntry 24 }

		alcetherStatsRxControlPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames that were recognized as control frames."
              ::= { alcetherStatsEntry 25 }

		alcetherStatsRxLenChkErrPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames for which the frame length field value
		   in the Type/Length field does not match the actual data bytes
		    length and is NOT a type field."
              ::= { alcetherStatsEntry 26 }

		alcetherStatsRxCodeErrPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames for which one or more nibbles were
		   signaled as errors during reception of the frame."
              ::= { alcetherStatsEntry 27 }

		alcetherStatsRxDvEventPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames for which a RX_DV event (packet not
		   too long enough to be valid packet) has been seen before the
		    correct frame."
              ::= { alcetherStatsEntry 28 }

		alcetherStatsRxPrevPktDropped 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames for which a packet has been dropped
		   (because of too small IFG) before the correct frame."
              ::= { alcetherStatsEntry 29 }

		alcetherStatsTx64Octets 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames of 64 bytes."
              ::= { alcetherStatsEntry 30 }

		alcetherStatsTx65to127Octets 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were between
		   65 and 127 bytes in length inclusive (excluding framing bits
		    but including FCS bytes)."
              ::= { alcetherStatsEntry 31 }

		alcetherStatsTx128to255Octets 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were between
		   128 and 255 bytes in length inclusive (excluding framing bits
		    but including FCS bytes)."
              ::= { alcetherStatsEntry 32 }

		alcetherStatsTx256to511Octets 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were between
		   256 and 511 bytes in length inclusive (excluding framing bits
		    but including FCS bytes)."
              ::= { alcetherStatsEntry 33 }

		alcetherStatsTx512to1023Octets 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were between
		   512 and 1023 bytes in length inclusive (excluding framing bits
		    but including FCS bytes)."
              ::= { alcetherStatsEntry 34 }

		alcetherStatsTx1024to1518Octets 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were between
		   1024 and 1518 bytes in length inclusive (excluding framing bits
		    but including FCS bytes)."
              ::= { alcetherStatsEntry 35 }

		alcetherStatsTx1519to2047Octets 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were between
		   1519 and 2047 bytes in length inclusive (excluding framing bits
		    but including FCS bytes)."
              ::= { alcetherStatsEntry 36 }

		alcetherStatsTx2048to4095Octets 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were between
		   2048 and 4095 bytes in length inclusive (excluding framing bits
		    but including FCS bytes)."
              ::= { alcetherStatsEntry 37 }

		alcetherStatsTx4096Octets 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were greater than
		    or equal to 4096 bytes in length and less than Max frame length
		    (excluding framing bits but including FCS bytes)."
              ::= { alcetherStatsEntry 38 }

		alcetherStatsTxRetryCount 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of collisions that the frames faced during
		   transmission attempts."
              ::= { alcetherStatsEntry 39 }

		alcetherStatsTxVlanTagPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames for which Type/Length field contains the
		   VLAN protocol identifier (0x8100)."
              ::= { alcetherStatsEntry 40 }

		alcetherStatsTxControlPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were recognised as control frames."
              ::= { alcetherStatsEntry 41 }

		alcetherStatsTxLatePkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of late collisions that occured beyond the collision window."
              ::= { alcetherStatsEntry 42 }

		alcetherStatsTxTotalBytesOnWire 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of bytes transmitted on wire, including all bytes from collided
		  attempts."
              ::= { alcetherStatsEntry 43 }

		alcetherStatsTxLenChkErrPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames for which the frame length field value
		  in the Type/Length field does not match the actual data bytes length and
		   is NOT a Type field."
              ::= { alcetherStatsEntry 44 }

		alcetherStatsTxExcDeferPkts		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames that were deferred in excess of 6071 nibble-times
		   in 100 Mbps, 24287 bit-times in 10 Mbps mode. These frames are dropped.(This
		   stat is only in case of Half duplex and excessive defer bit reset)."
              ::= { alcetherStatsEntry 45 }

-- 10 GIG specifics parameters

         alcether10GigTable OBJECT-TYPE
              SYNTAX SEQUENCE OF Alcether10GigEntry
              MAX-ACCESS not-accessible
              STATUS current
              DESCRIPTION
                  "A list of 10 Gig specifics entries."
              ::= { physicalPort 4 }

	alcether10GigEntry OBJECT-TYPE
              SYNTAX Alcether10GigEntry
              MAX-ACCESS not-accessible
              STATUS current
              DESCRIPTION
                  "This table will be populated with the 10 gig only entries.
                  The management interface can use it to specify if A or B is the primary."
              INDEX { ifIndex }
              ::= { alcether10GigTable 1 }

          Alcether10GigEntry ::= SEQUENCE {
	      alcether10GigPrimary	    INTEGER
	      }

	  alcether10GigPrimary OBJECT-TYPE
              SYNTAX INTEGER
		{	phyAprimary(1),
	 		phyBprimary(2),
	 		notApplicable(3)
		}
              MAX-ACCESS read-write
              STATUS current
              DESCRIPTION
                  "Setting the object to 1 will make phy A as primary, 2- phy B as pirmary.
                  Value 3 should not be set. "
              ::= { alcether10GigEntry 1 }

-- End of 10 GIG specifics parameters



-- Ethernet Driver Tables *****************************

        --  EsmHybridConf table contains the configuration
        --  information about the configured inactive media for the 
        --  hybrid port only.
        --  Implementation of this group is mandantory.
        --
        --  Note that entries in this MIB Table can NOT be created by the user, only modified


        esmHybridConfTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF EsmHybridConfEntry
            MAX-ACCESS  not-accessible
            STATUS  current
            DESCRIPTION
                "A list of inactive hybrid port instances."
            ::= { physicalPort 3 }

        esmHybridConfEntry  OBJECT-TYPE
            SYNTAX  EsmHybridConfEntry
            MAX-ACCESS  not-accessible
            STATUS  current
            DESCRIPTION
                "A ESM Physical Port entry."
            INDEX { ifIndex }
            ::= { esmHybridConfTable 1 }

        EsmHybridConfEntry ::= SEQUENCE {
            esmHybridPortCfgSpeed
                INTEGER,
            esmHybridPortCfgDuplexMode
                INTEGER,
	    esmHybridPortCfgAutoNegotiation
			INTEGER,
	    esmHybridPortCfgCrossover
			INTEGER,
	    esmHybridPortCfgFlow
			INTEGER,
            esmHybridPortCfgInactiveType
			INTEGER,
	    esmHybridPortCfgSFPType
			DisplayString
            }

        esmHybridPortCfgSpeed OBJECT-TYPE
            SYNTAX INTEGER {
                speed100(1),
                speed10(2),
                speedAuto(3),
                speed1000(5),
	        speed10000(6),
	        speedMax100(8),
		speedMax1000(9)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
            "The configured port line speed of this ESM port."
        ::= { esmHybridConfEntry 1 }

        esmHybridPortCfgDuplexMode OBJECT-TYPE
            SYNTAX INTEGER {
                fullDuplex(1),
                halfDuplex(2),
                autoDuplex(3)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
            "The configured port duplex mode of this ESM port.
            Note: GigaEthernet support only full-duplex."
        ::= { esmHybridConfEntry 2 }

        esmHybridPortCfgAutoNegotiation   OBJECT-TYPE
            SYNTAX INTEGER {
                enable(1),
                disable(2)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Allow the user to enable or disable the port auto negotiation."
	    DEFVAL { disable }
          ::= { esmHybridConfEntry 3 }

        esmHybridPortCfgCrossover   OBJECT-TYPE
            SYNTAX INTEGER {
                	mdi(1),
                	mdix(2),
			auto(3)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Allow the user to configure port crossover."
	    DEFVAL { auto }
          ::= { esmHybridConfEntry 4 }

        esmHybridPortCfgFlow   OBJECT-TYPE
            SYNTAX INTEGER {
                disable(1),
				enabledXmit(2),
                enabledRcv(3),
                enabledXmitAndRcv(4)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "This object is used for flow control of hybrid ports. It is similar to the dot3PauseAdminMode
		  object in dot3PauseTable. It is used to configure pause for fiber media."
	    DEFVAL { disable }
          ::= { esmHybridConfEntry 5 }

 	esmHybridPortCfgInactiveType OBJECT-TYPE
            SYNTAX INTEGER {
                fiber(1),
                copper(2)
            }
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "This object is only applicable to hybrid ports .
                  It indicates the configured inactive media type."
          ::= { esmHybridConfEntry 6 }

	esmHybridPortCfgSFPType OBJECT-TYPE      
            SYNTAX      DisplayString (SIZE (0..64))      
            MAX-ACCESS read-only      
            STATUS      current     
            DESCRIPTION      
                "This object is only applicable to fiber ports.      
                The string indicates the type of SFP/GBIC of active media."      
          ::= { esmHybridConfEntry 7 }    


-- End-to-End Flow Vlan Configuration *****************

	esmE2EFlowVlan OBJECT-TYPE
	    SYNTAX INTEGER (0 .. 4094)
	    MAX-ACCESS read-write
	    STATUS current
	    DESCRIPTION
		"0 - Deleting End-to-End flow control
		 1-4094 - Enable End-to-End flow control and use the Vlan configured as for End-to-End flow"
	    ::= { alcatelIND1PortMIBObjects 3 }


-- Digital Diagnostics Monitoring (DDM) **************************

ddmConfig OBJECT-TYPE
	SYNTAX		INTEGER {
					enable(1),
					disable(2)
				}
	MAX-ACCESS	read-write
	STATUS		current
	DESCRIPTION
		"This object enables/disables DDM software feature in the system."
	DEFVAL		{ disable }
	::= { ddmConfiguration 1 }

ddmTrapConfig OBJECT-TYPE
	SYNTAX		INTEGER {
					enable(1),
					disable(2)
				}
	MAX-ACCESS	read-write
	STATUS		current
	DESCRIPTION
		"This objects enables/disables traps for DDM warning/alarm threshold violations."
	DEFVAL		{ disable }
	::= { ddmConfiguration 2 }

ddmNotificationType	OBJECT-TYPE
	SYNTAX		INTEGER 
				{
					clearViolation(1),
					highAlarm(2),
					highWarning(3),
					lowWarning(4),
					lowAlarm(5)
				}
	MAX-ACCESS	accessible-for-notify
	STATUS		current
	DESCRIPTION
		"This object defines the trap type for monitored DDM parameters."
	::=	{ ddmConfiguration 3 }



-- esmViolationRecoveryTime Configuration *****************

esmViolationRecoveryTrap OBJECT-TYPE
	SYNTAX		INTEGER {
					enable(1),
					disable(2)
				}
	MAX-ACCESS	read-write
	STATUS		current
	DESCRIPTION
		"This objects enables/disables traps for user-port shutdown"
	DEFVAL		{ disable }
	::= { esmViolationRecovery 1 }


esmViolationRecoveryTime OBJECT-TYPE
	    SYNTAX INTEGER (0 .. 600)
	    MAX-ACCESS read-write
	    STATUS current
	    DESCRIPTION
		"0 - Disable the timer
		30 - 600 - timeout value to re-enable the UserPort ports"
	    ::= { esmViolationRecovery 2 }

esmViolationRecoveryNotificationType	OBJECT-TYPE
	SYNTAX		INTEGER 
				{
					clearViolation(1)
				}
	MAX-ACCESS	accessible-for-notify
	STATUS		current
	DESCRIPTION
		"This object defines the trap type for monitored violation-recovery parameters."
	::=	{ esmViolationRecovery 3 }


ddmInfoTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF DdmEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ddmInfoTable has an entry for each SFP/XFP in the
         system that supports Digital Diagnostic Monitoring (DDM). The table is
         indexed by ifIndex. Each row in this table is dynamically added
         and removed internally by the system based on the presence or absence
         of DDM capable SFP/XFP components."
    ::= { physicalPort 5 }

ddmInfoEntry OBJECT-TYPE
    SYNTAX      DdmEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each row represents a particular SFP/XFP that supports Digital
         Diagnostic Monitoring.
         Entries are created and deleted internally by the system."
    INDEX { ifIndex }
    ::= { ddmInfoTable 1}

DdmEntry ::= SEQUENCE
    {
        ddmTemperature                   Integer32,
        ddmTempLowWarning                Integer32,
        ddmTempLowAlarm                  Integer32,
        ddmTempHiWarning                 Integer32,
        ddmTempHiAlarm                   Integer32,
        ddmSupplyVoltage                 Integer32,
        ddmSupplyVoltageLowWarning       Integer32,
        ddmSupplyVoltageLowAlarm         Integer32,
        ddmSupplyVoltageHiWarning        Integer32,
        ddmSupplyVoltageHiAlarm          Integer32,
        ddmTxBiasCurrent                 Integer32,
        ddmTxBiasCurrentLowWarning       Integer32,
        ddmTxBiasCurrentLowAlarm         Integer32,
        ddmTxBiasCurrentHiWarning        Integer32,
        ddmTxBiasCurrentHiAlarm          Integer32,
        ddmTxOutputPower                 Integer32,
        ddmTxOutputPowerLowWarning       Integer32,
        ddmTxOutputPowerLowAlarm         Integer32,
        ddmTxOutputPowerHiWarning        Integer32,
        ddmTxOutputPowerHiAlarm          Integer32,
        ddmRxOpticalPower                Integer32,
        ddmRxOpticalPowerLowWarning      Integer32,
        ddmRxOpticalPowerLowAlarm        Integer32,
        ddmRxOpticalPowerHiWarning       Integer32,
        ddmRxOpticalPowerHiAlarm         Integer32
    }

ddmTemperature                 OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -150000..150000)
	UNITS		"thousandth of a degree celcius"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTemperature indicates the current temperature
         of the SFP/XFP in 1000s of degrees Celsius.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 1 }

ddmTempLowWarning              OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -150000..150000)
	UNITS       "thousandth of a degree celcius"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTempLowWarning indicates the temperature
         of the SFP/XFP in 1000s of degrees Celsius that triggers a low-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 2 }

ddmTempLowAlarm                OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -150000..150000)
	UNITS       "thousandth of a degree celcius"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTempLowAlarm indicates the temperature
         of the SFP/XFP in 1000s of degrees Celsius that triggers a low-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 3 }

ddmTempHiWarning               OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -150000..150000)
	UNITS       "thousandth of a degree celcius"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTempHiWarning indicates the temperature
         of the SFP/XFP in 1000s of degrees Celsius that triggers a hi-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 4 }

ddmTempHiAlarm                 OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -150000..150000)
	UNITS       "thousandth of a degree celcius"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTempHiAlarm indicates the temperature
         of the SFP/XFP in 1000s of degrees Celsius that triggers a hi-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 5 }

ddmSupplyVoltage               OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a volt"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmSupplyVoltage indicates the current supply
         voltage of the SFP/XFP in 1000s of Volts (V).
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 6 }

ddmSupplyVoltageLowWarning     OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a volt"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmSupplyVoltageLowWarning indicates the supply
         voltage of the SFP/XFP in 1000s of Volts (V) that triggers a low-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 7 }

ddmSupplyVoltageLowAlarm       OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a volt"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmSupplyVoltageLowAlarm indicates the supply
         voltage of the SFP/XFP in 1000s of Volts (V) that triggers a low-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 8 }

ddmSupplyVoltageHiWarning      OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a volt"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmSupplyVoltageHiWarning indicates the supply
         voltage of the SFP/XFP in 1000s of Volts (V) that triggers a hi-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 9 }

ddmSupplyVoltageHiAlarm        OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a volt"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmSupplyVoltageHiAlarm indicates the supply
         voltage of the SFP/XFP in 1000s of Volts (V) that triggers a hi-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 10 }

ddmTxBiasCurrent               OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a milli-Ampere"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxBiasCurrent indicates the current Transmit
         Bias Current of the SFP/XFP in 1000s of milli-Amperes (mA).
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 11 }

ddmTxBiasCurrentLowWarning     OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a milli-Ampere"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxBiasCurrentLowWarning indicates the Transmit
         Bias Current of the SFP/XFP in 1000s of milli-Amperes (mA) that triggers a
         low-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 12 }

ddmTxBiasCurrentLowAlarm       OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a milli-Ampere"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxBiasCurrentLowAlarm indicates the Transmit
         Bias Current of the SFP/XFP in 1000s of milli-Amperes (mA) that triggers a
         low-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 13 }

ddmTxBiasCurrentHiWarning      OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a milli-Ampere"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxBiasCurrentHiWarning indicates the Transmit
         Bias Current of the SFP/XFP in 1000s milli-Amperes (mA) that triggers a
         hi-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 14 }

ddmTxBiasCurrentHiAlarm        OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a milli-Ampere"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxBiasCurrentHiAlarm indicates the Transmit
         Bias Current of the SFP/XFP in 1000s milli-Amperes (mA) that triggers a
         hi-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 15 }

ddmTxOutputPower               OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxOutputPower indicates the current Output
         Power of the SFP/XFP in 1000s of dBm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 16 }

ddmTxOutputPowerLowWarning     OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxOutputPowerLowWarning indicates the Output Power
         of the SFP/XFP in 1000s of dBm that triggers a low-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 17 }

ddmTxOutputPowerLowAlarm       OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxOutputPowerLowAlarm indicates the Output Power
         of the SFP/XFP in 1000s of dBm that triggers a low-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 18 }

ddmTxOutputPowerHiWarning      OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxOutputPowerHiWarning indicates the Output Power
         of the SFP/XFP in 1000s of dBm that triggers a hi-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 19 }

ddmTxOutputPowerHiAlarm        OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxOutputPowerHiAlarm indicates the Output Power
         of the SFP/XFP in 1000s of dBm that triggers a hi-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 20 }

ddmRxOpticalPower              OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmRxOpticalPower indicates the current Received
         Optical Power of the SFP/XFP in 1000s of dBm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 21 }

ddmRxOpticalPowerLowWarning    OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmRxOpticalPowerLowWarning indicates the Received
         Optical Power of the SFP/XFP in 1000s of dBm that triggers a
         low-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 22 }

ddmRxOpticalPowerLowAlarm      OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmRxOpticalPowerLowAlarm indicates the Received
         Optical Power of the SFP/XFP in 1000s of dBm that triggers a
         low-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 23 }

ddmRxOpticalPowerHiWarning     OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmRxOpticalPowerHiWarning indicates the Received
         Optical Power of the SFP/XFP in 1000s of dBm that triggers a
         hi-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 24 }

ddmRxOpticalPowerHiAlarm       OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmRxOpticalPowerHiAlarm indicates the Received
         Optical Power of the SFP/XFP in 1000s of dBm that triggers a
         hi-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 25 }

-- Ethernet Driver Trap *********************

esmDrvTrapDropsLink  NOTIFICATION-TYPE
    OBJECTS    {
                  esmPortSlot,
		  esmPortIF,
                  ifInErrors,
                  ifOutErrors,
		  esmDrvTrapDrops
               }
    STATUS  current
    DESCRIPTION
           "When the Ethernet code drops the link because of
            excessive errors, a Trap is sent."
    ::= { cmmEsmDrvTraps 0 1 }

e2eStackTopoChangeTrap NOTIFICATION-TYPE
     OBJECTS    {
                   esmE2EFlowVlan
                }
     STATUS  current
     DESCRIPTION
            "Trap  Generated when  Stack Topology changes."
     ::= { cmmEsmDrvTraps 0 2 }

ddmTemperatureThresholdViolated NOTIFICATION-TYPE
	OBJECTS		{
					ifIndex,
					ddmNotificationType, 
					ddmTemperature
				}
	STATUS		current
	DESCRIPTION
		"This object notifies management station if an SFP/XFP/SFP+ temperature has crossed any 
		 threshold or reverted from previous threshold violation for a port represented by ifIndex.
		 It also provides the current realtime value of SFP/XFP/SFP+ temperature."
	::=	{ ddmNotifications 0 1 }

ddmVoltageThresholdViolated NOTIFICATION-TYPE
    OBJECTS     {
                    ifIndex,
                    ddmNotificationType,
                    ddmSupplyVoltage
                }
    STATUS      current
    DESCRIPTION
        "This object notifies management station if an SFP/XFP/SFP+ supply voltage has crossed any
         threshold or reverted from previous threshold violation for a port represented by ifIndex.
         It also provides the current realtime value of SFP/XFP/SFP+ supply voltage."
    ::= { ddmNotifications 0 2 }

ddmCurrentThresholdViolated NOTIFICATION-TYPE
    OBJECTS     {
                    ifIndex,
                    ddmNotificationType,
                    ddmTxBiasCurrent
                }
    STATUS      current
    DESCRIPTION
        "This object notifies management station if an SFP/XFP/SFP+ Tx bias current has crossed any
         threshold or reverted from previous threshold violation for a port represented by ifIndex.
         It also provides the current realtime value of SFP/XFP/SFP+ Tx bias current."
    ::= { ddmNotifications 0 3 }

ddmTxPowerThresholdViolated NOTIFICATION-TYPE
    OBJECTS     {
                    ifIndex,
                    ddmNotificationType,
                    ddmTxOutputPower
                }
    STATUS      current
    DESCRIPTION
        "This object notifies management station if an SFP/XFP/SFP+ Tx output power has crossed any
         threshold or reverted from previous threshold violation for a port represented by ifIndex.
         It also provides the current realtime value of SFP/XFP/SFP+ Tx output power."
    ::= { ddmNotifications 0 4 }


ddmRxPowerThresholdViolated NOTIFICATION-TYPE
    OBJECTS     {
                    ifIndex,
                    ddmNotificationType,
                    ddmRxOpticalPower
                }
    STATUS      current
    DESCRIPTION
        "This object notifies management station if an SFP/XFP/SFP+ Rx optical power has crossed any
         threshold or reverted from previous threshold violation for a port represented by ifIndex.
         It also provides the current realtime value of SFP/XFP/SFP+ Rx optical power."
    ::= { ddmNotifications 0 5 }


esmViolationRecoveryTimeout NOTIFICATION-TYPE
    OBJECTS     {
                    ifIndex,
                    esmViolationRecoveryNotificationType
                }
    STATUS      current
    DESCRIPTION
        "This object notifies management station if User-Port ports get re-enabled after esm violation recovery time"
    ::= { esmViolationNotifications 0 1 }

-- conformance information

alcatelIND1PortMIBCompliances OBJECT IDENTIFIER ::= { alcatelIND1PortMIBConformance 1 }
alcatelIND1PortMIBGroups      OBJECT IDENTIFIER ::= { alcatelIND1PortMIBConformance 2 }

-- compliance statements

esmConfPortCompliance MODULE-COMPLIANCE
    STATUS  current
    DESCRIPTION
            "The compliance statement for the configuration of Ethernet
            ports."
    MODULE  -- this module
        MANDATORY-GROUPS { 	esmConfMIBGroup, 
							esmDetectedConfMIBGroup, 
							esmPortModeMIBGroup,
							ddmInfoGroup,
							ddmConfigGroup,
							ddmNotificationsGroup,
							violationRecoveryGroup,
							violationNotificationsGroup
						 }
    ::= { alcatelIND1PortMIBCompliances 1 }

alcEtherStatsCompliance MODULE-COMPLIANCE
    STATUS  current
    DESCRIPTION
            "The compliance statement for the Statistics of the Ethernet
            ports."
    MODULE  -- this module
        MANDATORY-GROUPS { alcEtherStatsMIBGroup }

    ::= { alcatelIND1PortMIBCompliances 2 }

-- units of conformance



esmConfMIBGroup OBJECT-GROUP
    OBJECTS { esmPortCfgSpeed,
              esmPortCfgDuplexMode, esmPortCfgIFG,
              esmPortPauseSlotTime, esmPortMaxFloodRate,
	      esmPortFloodMcastEnable, esmPortCfgMaxFrameSize, esmPortCfgAutoNegotiation,
	      esmPortCfgCrossover, esmPortCfgFlow, esmPortFloodUnknownUcastEnable,
	      esmPortMaxUnknownUcastFloodRate,esmPortMaxMcastFloodRate,esmPortFloodBcastEnable,
	      esmPortMaxFloodRateLimit,esmPortMaxUnknownUcastFloodRateLimit,esmPortMaxMcastFloodRateLimit, esmPortCfgSFPType     	
            }
    STATUS  current
    DESCRIPTION
            "A collection of objects to support the management of global
            configuration parameters of the Ethernet ports."
    ::= { alcatelIND1PortMIBGroups 1 }

esmDetectedConfMIBGroup OBJECT-GROUP
    OBJECTS { esmPortAutoSpeed, esmPortAutoDuplexMode
            }
    STATUS  current
    DESCRIPTION
            "A collection of objects to support the Detected
            configuration parameters of the Ethernet ports."
    ::= { alcatelIND1PortMIBGroups 2 }

alcEtherStatsMIBGroup OBJECT-GROUP
    OBJECTS { alcetherClearStats, alcetherLastClearStats,
	      alcetherStatsCRCAlignErrors, alcetherStatsRxUndersizePkts,
              alcetherStatsTxUndersizePkts, alcetherStatsTxOversizePkts,
	      alcetherStatsRxJabbers, alcetherStatsRxCollisions,
	      alcetherStatsTxCollisions, alcetherStatsPkts64Octets,
              alcetherStatsPkts65to127Octets, alcetherStatsPkts128to255Octets,
              alcetherStatsPkts256to511Octets,
	      alcetherStatsPkts512to1023Octets,
	      alcetherStatsPkts1024to1518Octets,
              gigaEtherStatsPkts1519to4095Octets,
	      gigaEtherStatsPkts4096to9215Octets,
		alcetherStatsPkts1519to2047Octets,
		alcetherStatsPkts2048to4095Octets,
		alcetherStatsPkts4096Octets,
		alcetherStatsRxGiantPkts,
		alcetherStatsRxDribbleNibblePkts,
		alcetherStatsRxLongEventPkts,
		alcetherStatsRxVlanTagPkts,
		alcetherStatsRxControlPkts,
		alcetherStatsRxLenChkErrPkts,
		alcetherStatsRxCodeErrPkts,
		alcetherStatsRxDvEventPkts,
		alcetherStatsRxPrevPktDropped,
		alcetherStatsTx64Octets,
		alcetherStatsTx65to127Octets,
		alcetherStatsTx128to255Octets,
		alcetherStatsTx256to511Octets,
		alcetherStatsTx512to1023Octets,
		alcetherStatsTx1024to1518Octets,
		alcetherStatsTx1519to2047Octets,
		alcetherStatsTx2048to4095Octets,
		alcetherStatsTx4096Octets,
		alcetherStatsTxRetryCount,
		alcetherStatsTxVlanTagPkts,
		alcetherStatsTxControlPkts,
		alcetherStatsTxLatePkts,
		alcetherStatsTxTotalBytesOnWire,
		alcetherStatsTxLenChkErrPkts,
		alcetherStatsTxExcDeferPkts

            }
    STATUS  current
    DESCRIPTION
            "A collection of objects to provide all the statistics related
             to the Ethernet and GigaEthernert ports."
    ::= { alcatelIND1PortMIBGroups 3 }

alcPortNotificationGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
	esmDrvTrapDropsLink
	}
    STATUS current
    DESCRIPTION
 	    "The Port MIB Notification Group."
    ::= { alcatelIND1PortMIBGroups 4 }

esmPortModeMIBGroup OBJECT-GROUP
    OBJECTS { esmPortRunningMode,
              esmPortSavedMode  
            }
    STATUS  current
    DESCRIPTION
            "A collection of objects to support the management of global
            configuration parameters of the stacking ports."
    ::= { alcatelIND1PortMIBGroups 5 }

	ddmInfoGroup	OBJECT-GROUP
	OBJECTS	{
				ddmTemperature,
        		ddmTempLowWarning,
        		ddmTempLowAlarm,
        		ddmTempHiWarning,
        		ddmTempHiAlarm,
        		ddmSupplyVoltage,
        		ddmSupplyVoltageLowWarning,
        		ddmSupplyVoltageLowAlarm,
        		ddmSupplyVoltageHiWarning,
        		ddmSupplyVoltageHiAlarm,
        		ddmTxBiasCurrent,
        		ddmTxBiasCurrentLowWarning,
        		ddmTxBiasCurrentLowAlarm,
        		ddmTxBiasCurrentHiWarning,
        		ddmTxBiasCurrentHiAlarm,
        		ddmTxOutputPower,
        		ddmTxOutputPowerLowWarning,
        		ddmTxOutputPowerLowAlarm,
        		ddmTxOutputPowerHiWarning,
        		ddmTxOutputPowerHiAlarm,
        		ddmRxOpticalPower,
        		ddmRxOpticalPowerLowWarning,
        		ddmRxOpticalPowerLowAlarm,
        		ddmRxOpticalPowerHiWarning,
        		ddmRxOpticalPowerHiAlarm
			}
	STATUS	current
	DESCRIPTION
			"A collection of objects to provide digital diagnostics information
			 related to SFPs, XFPs, and SFP+s."
	::=	{ alcatelIND1PortMIBGroups 6 }

	ddmConfigGroup	OBJECT-GROUP
	OBJECTS {
				ddmConfig,
				ddmTrapConfig			
			}
	STATUS	current
	DESCRIPTION
			"A collection of objects to allow configuration of DDM and DDM traps."
	::=	{ alcatelIND1PortMIBGroups 7 }

	ddmNotificationsGroup	NOTIFICATION-GROUP
	NOTIFICATIONS	{
						ddmTemperatureThresholdViolated,
						ddmVoltageThresholdViolated,
						ddmCurrentThresholdViolated,
						ddmTxPowerThresholdViolated,
						ddmRxPowerThresholdViolated
					}
	STATUS	current
	DESCRIPTION
			"A collection of notifications used to indicate DDM threshold violations."
	::= { alcatelIND1PortMIBGroups 8 }

	violationRecoveryGroup	OBJECT-GROUP
	OBJECTS {
				esmViolationRecoveryTrap,
				esmViolationRecoveryTime			
			}
	STATUS	current
	DESCRIPTION
			"A collection of objects to allow configuration of violationRecovery."
	::=	{ alcatelIND1PortMIBGroups 9 }

	violationNotificationsGroup NOTIFICATION-GROUP
	NOTIFICATIONS	{
						esmViolationRecoveryTimeout
			}
	STATUS	current
	DESCRIPTION
			"A collection of notifications used to indicate esm violation recovery timeout."
	::= { alcatelIND1PortMIBGroups 10 }
	END