1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
|
-- *****************************************************************
-- RBN-ENVMON-MIB Environmental Monitor MIB
--
-- Copyright (c) 1999-2007, 2010-2011 Ericsson AB
-- All rights reserved.
--
-- *****************************************************************
RBN-ENVMON-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Unsigned32,
Integer32
FROM SNMPv2-SMI
DisplayString,
TruthValue,
TEXTUAL-CONVENTION
FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF
entPhysicalIndex
FROM ENTITY-MIB
rbnMgmt
FROM RBN-SMI;
rbnEnvMonMIB MODULE-IDENTITY
LAST-UPDATED "201210030000Z" -- October 3, 2012
ORGANIZATION "Ericsson AB."
CONTACT-INFO
" Ericsson AB.
Postal: 100 Headquarters Dr.
San Jose, CA 95134
USA
Phone: +1 408 750 5000
Fax: +1 408 750 5599
"
DESCRIPTION
"The MIB used to genericially manage Environmental
Monitor functionality on network devices."
REVISION "201210030000Z" -- October 3, 2012
DESCRIPTION
"Removed DISPLAY-HINT from RbnVoltage and RbnFanSpeed."
REVISION "201101191800Z" -- Jan 19, 2011
DESCRIPTION
"Update CONTACT-INFO & ORGANIZATION. "
REVISION "201011110000Z" -- Nov 11, 2010
DESCRIPTION
"Add new Table rbnEntityTempSensorTable. This will display
the TempSensor Details for all the entities. "
REVISION "200601160000Z" -- January 16, 2006
DESCRIPTION
"Add textual convention RbnFanSpeed. Add new OIDs:
rbnFanUnitID
rbnFanUnitDescr
rbnFanSpeedCurrent
rbnEnvMonFanSpeedObjectGroup
rbnEnvMonMIBComplianceV4
"
REVISION "200206050000Z" -- June 5, 2002
DESCRIPTION
"Update/correct CONTACT-INFO. Fix syntax errors on IMPORTS list,
ranges on Integer32, and size for DisplayString types.
Restore the incorrectly deprecated OIDs to current, since they
are still supported."
REVISION "200107250000Z" -- July 25, 2001
DESCRIPTION
"Added new OIDs:
rbnFanStatus
rbnPowerStatus
rbnFanStatusChange
rbnPowerStatusChange
rbnEnvMonMIBObjectGroupV2
rbnEnvMonMIBNotificationGroupV2
rbnEnvMonMIBComplianceV3
Deprecated the OIDs:
rbnFanFail
rbnPowerFail
rbnFanFailChange
rbnPowerFailChange
rbnEnvMonMIBObjectGroup
rbnEnvMonMIBNotificationGroup
rbnEnvMonMIBComplianceV2
"
REVISION "200004240000Z" -- May 24, 2000
DESCRIPTION
"Added voltage and temperature sensor tables."
REVISION "199903100000Z" -- Mar 10, 1999
DESCRIPTION
"Initial version."
::= { rbnMgmt 4 }
rbnEnvMonMIBNotifications OBJECT IDENTIFIER
::= { rbnEnvMonMIB 0 }
rbnEnvMonMIBObjects OBJECT IDENTIFIER
::= { rbnEnvMonMIB 1 }
rbnEnvMonMIBConformance OBJECT IDENTIFIER
::= { rbnEnvMonMIB 2 }
-- Textual Conventions
RbnVoltage ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents a voltage value. The value is millivolts.
For example, a voltage of 5.5V would be represented
by the value 5500."
SYNTAX Unsigned32 (0..50000)
RbnTemperature ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"Represents a temperature, in degrees Celsius. In the
unlikely event that the temperature to be reported is
less than 0 degrees Celsius, a value of 0 will be
used. Likewise, if the temperature is greater than
100, a value of 100 will be used."
SYNTAX Unsigned32 (0..100)
RbnFanSpeed ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents a fan speed value in units of Revolutions Per
Minute(RPM)."
SYNTAX Unsigned32
-- MIB Objects
rbnFanStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbnFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per fan test point.
Note that there is not necessarily a one-to-one
relationship between fan test points and fan
assemblies; a single test point may be used to
monitor the status of multiple fans."
::= { rbnEnvMonMIBObjects 1 }
rbnFanStatusEntry OBJECT-TYPE
SYNTAX RbnFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular fan test point"
INDEX { rbnFanIndex }
::= { rbnFanStatusTable 1 }
RbnFanStatusEntry ::= SEQUENCE {
rbnFanIndex Integer32,
rbnFanDescr DisplayString,
rbnFanFail TruthValue,
rbnFanStatus INTEGER
}
rbnFanIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of a fan test point."
::= { rbnFanStatusEntry 1 }
rbnFanDescr OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of a fan test point. If an instance of
this object is associated with a single fan assembly,
then the value of this object should be the same as the
name by which the assembly is normally referenced. If
an instance is associated with multiple fan assemblies,
then the value of this object should contain the names
of all of the fan assemblies being monitored."
::= { rbnFanStatusEntry 2 }
rbnFanFail OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The status of a fan test point. If an instance of
this object has the value true, then a fan monitored
by the test point has failed. If an instance of
this object has the value false, then the fan (or fans)
monitored by the test point are operational."
::= { rbnFanStatusEntry 3 }
rbnFanStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
failed(2),
absent(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of a fan test point. If an instance of
this object has the value normal, then the fan (or
fans) monitored by the test point is operational. If
an instance of this object has the value failed, then
the fan (or fans) monitored by the test point has
failed. If an instance of this object has the value
absent, then the fan (or fans) monitored by this test
point is not present. If an instance of this object has
the value unknown, then the test point is unable to
monitor the fan (or fans)."
::= { rbnFanStatusEntry 4 }
rbnPowerStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbnPowerStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per power test point.
Note that there is not necessarily a one-to-one
relationship between power test points and power
supply assemblies; a single test point may be used
to monitor the status of multiple power supplies."
::= { rbnEnvMonMIBObjects 2 }
rbnPowerStatusEntry OBJECT-TYPE
SYNTAX RbnPowerStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular power test point"
INDEX { rbnPowerIndex }
::= { rbnPowerStatusTable 1 }
RbnPowerStatusEntry ::= SEQUENCE {
rbnPowerIndex Integer32,
rbnPowerDescr DisplayString,
rbnPowerFail TruthValue,
rbnPowerStatus INTEGER
}
rbnPowerIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of a power test point."
::= { rbnPowerStatusEntry 1 }
rbnPowerDescr OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of a power supply test point. If an
instance of this object is associated with a single
power supply assembly, then the value of this object
should be the same as the name by which the assembly
is normally referenced. If an instance is associated
with multiple power supply assemblies, then the value
of this object should contain the names of all of the
power supply assemblies being monitored."
::= { rbnPowerStatusEntry 2 }
rbnPowerFail OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The status of a power test point. If an instance of
this object has the value true, then a power supply
monitored by the test point has failed. If an instance
of this object has the value false, then the power
supply (or supplies) monitored by the test point are
operational."
::= { rbnPowerStatusEntry 3 }
rbnPowerStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
failed(2),
absent(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of a power test point. If an instance of
this object has the value normal, then the power
supply (or supplies) monitored by the test point is
operational. If an instance of this object has the
value failed, then the power supply (or supplies)
monitored by the test point has failed. If an instance
of this object has the value absent, then the power
supply (or supplies) monitored by this test point is
not present. If an instance of this object has
the value unknown, then the test point is unable to
monitor the power supply (or supplies)."
::= { rbnPowerStatusEntry 4 }
rbnVoltageSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbnVoltageSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per voltage test point.
Each physical entity (e.g. cards) in the system may
contain zero or more voltage test points."
::= { rbnEnvMonMIBObjects 3 }
rbnVoltageSensorEntry OBJECT-TYPE
SYNTAX RbnVoltageSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular voltage test point."
INDEX { entPhysicalIndex, rbnVoltageIndex }
::= { rbnVoltageSensorTable 1 }
RbnVoltageSensorEntry ::= SEQUENCE {
rbnVoltageIndex Integer32,
rbnVoltageDescr DisplayString,
rbnVoltageDesired RbnVoltage,
rbnVoltageCurrent RbnVoltage
}
rbnVoltageIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary value which uniquely identifies a
voltage test point on a particular physical entity.
Index values for different test points are not
necessarily contiguous."
::= { rbnVoltageSensorEntry 1 }
rbnVoltageDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of a voltage test point. Typically
an instance of this object will hold a user-friendly
description of the physical entity and the level of
voltage being monitored by this test point."
::= { rbnVoltageSensorEntry 2 }
rbnVoltageDesired OBJECT-TYPE
SYNTAX RbnVoltage
UNITS "millivolts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The desired voltage level for this test point. If
the monitored voltage level (rbnVoltageCurrent) is
equal to this value, then the system is performing
as designed."
::= { rbnVoltageSensorEntry 3 }
rbnVoltageCurrent OBJECT-TYPE
SYNTAX RbnVoltage
UNITS "millivolts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current voltage level at this test point."
::= { rbnVoltageSensorEntry 4 }
rbnCpuTempSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbnCpuTempSensorEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This table contains one row per CPU temperature
sensor. Each physical entity in the system may have
zero or more CPUs. Each of those CPUs that has a
temperature sensor will show up here."
::= { rbnEnvMonMIBObjects 4 }
rbnCpuTempSensorEntry OBJECT-TYPE
SYNTAX RbnCpuTempSensorEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Information about a particular CPU temperature test
point."
INDEX { entPhysicalIndex, rbnCpuTempIndex }
::= { rbnCpuTempSensorTable 1 }
RbnCpuTempSensorEntry ::= SEQUENCE {
rbnCpuTempIndex Integer32,
rbnCpuTempDescr DisplayString,
rbnCpuTempCurrent RbnTemperature
}
rbnCpuTempIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An arbitrary value which uniquely identifies a CPU on
a particular physical entity. Index values for
different CPUs are not necessarily contiguous."
::= { rbnCpuTempSensorEntry 1 }
rbnCpuTempDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The description of a CPU temperature test
point. Typically an instance of this object will hold
a user-friendly description of the physical entity
and a description of the CPU being monitored by this
test point."
::= { rbnCpuTempSensorEntry 2 }
rbnCpuTempCurrent OBJECT-TYPE
SYNTAX RbnTemperature
UNITS "degrees"
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The current temperature of this CPU."
::= { rbnCpuTempSensorEntry 3 }
rbnFanSpeedTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbnFanSpeedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per fan unit within a fan
test point."
::= { rbnEnvMonMIBObjects 5 }
rbnFanSpeedEntry OBJECT-TYPE
SYNTAX RbnFanSpeedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular fan unit within a fan
test point."
INDEX { rbnFanIndex, rbnFanUnitID }
::= { rbnFanSpeedTable 1 }
RbnFanSpeedEntry ::= SEQUENCE {
rbnFanUnitID Integer32,
rbnFanUnitDescr DisplayString,
rbnFanSpeedCurrent RbnFanSpeed
}
rbnFanUnitID OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the fan identification number that describes the
specific location of the fan unit within a fan test point."
::= { rbnFanSpeedEntry 1 }
rbnFanUnitDescr OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of the fan unit within a fan test point."
::= { rbnFanSpeedEntry 2 }
rbnFanSpeedCurrent OBJECT-TYPE
SYNTAX RbnFanSpeed
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current speed of this fan unit."
::= { rbnFanSpeedEntry 3 }
rbnEntityTempSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbnEntityTempSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per temperature
sensor on the physical entity."
::= { rbnEnvMonMIBObjects 6 }
rbnEntityTempSensorEntry OBJECT-TYPE
SYNTAX RbnEntityTempSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular temperature test
point."
INDEX { entPhysicalIndex, rbnEntityTempIndex }
::= { rbnEntityTempSensorTable 1 }
RbnEntityTempSensorEntry ::= SEQUENCE {
rbnEntityTempIndex Integer32,
rbnEntityTempDescr DisplayString,
rbnEntityTempCurrent RbnTemperature
}
rbnEntityTempIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary value which uniquely identifies a
particular physical entity. Index values are
not necessarily contiguous."
::= { rbnEntityTempSensorEntry 1 }
rbnEntityTempDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of a temperature test
point. Typically an instance of this object will hold
a user-friendly description of the physical entity
being monitored by this test point."
::= { rbnEntityTempSensorEntry 2 }
rbnEntityTempCurrent OBJECT-TYPE
SYNTAX RbnTemperature
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current temperature of this entity in degrees Celsius."
::= { rbnEntityTempSensorEntry 3 }
-- Notifications
rbnFanFailChange NOTIFICATION-TYPE
OBJECTS { rbnFanFail }
STATUS deprecated
DESCRIPTION
"A rbnFanFailChange notification signifies
that the value of an instance of rbnFanFail
has changed."
::= { rbnEnvMonMIBNotifications 1 }
rbnPowerFailChange NOTIFICATION-TYPE
OBJECTS { rbnPowerFail }
STATUS deprecated
DESCRIPTION
"A rbnPowerFailChange notification signifies
that the value of an instance of rbnPowerFail
has changed"
::= { rbnEnvMonMIBNotifications 2 }
rbnFanStatusChange NOTIFICATION-TYPE
OBJECTS { rbnFanStatus }
STATUS current
DESCRIPTION
"A rbnFanStatusChange notification signifies
that the value of an instance of rbnFanStatus
has changed."
::= { rbnEnvMonMIBNotifications 3 }
rbnPowerStatusChange NOTIFICATION-TYPE
OBJECTS { rbnPowerStatus }
STATUS current
DESCRIPTION
"A rbnPowerStatusChange notification signifies
that the value of an instance of rbnPowerStatus
has changed"
::= { rbnEnvMonMIBNotifications 4 }
-- Conformance Statements
rbnEnvMonMIBGroups OBJECT IDENTIFIER
::= { rbnEnvMonMIBConformance 1 }
rbnEnvMonMIBCompliances OBJECT IDENTIFIER
::= { rbnEnvMonMIBConformance 2 }
rbnEnvMonMIBObjectGroup OBJECT-GROUP
OBJECTS { rbnFanDescr, rbnFanFail,
rbnPowerDescr, rbnPowerFail
}
STATUS deprecated
DESCRIPTION
"A collection of objects providing
environmental monitor information."
::= { rbnEnvMonMIBGroups 1 }
rbnEnvMonMIBNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { rbnFanFailChange,
rbnPowerFailChange
}
STATUS deprecated
DESCRIPTION
"A collection of notifications providing
fan and power environmental monitor information."
::= { rbnEnvMonMIBGroups 2 }
rbnEnvMonVoltageObjectGroup OBJECT-GROUP
OBJECTS { rbnVoltageDescr, rbnVoltageDesired,
rbnVoltageCurrent
}
STATUS current
DESCRIPTION
"A collection of objects providing voltage
environmental monitor information."
::= { rbnEnvMonMIBGroups 3 }
rbnEnvMonTempObjectGroup OBJECT-GROUP
OBJECTS { rbnCpuTempDescr, rbnCpuTempCurrent
}
STATUS deprecated
DESCRIPTION
"A collection of objects providing temperature
environmental monitor information."
::= { rbnEnvMonMIBGroups 4 }
rbnEnvMonMIBObjectGroupV2 OBJECT-GROUP
OBJECTS { rbnFanDescr, rbnFanStatus,
rbnPowerDescr, rbnPowerStatus
}
STATUS current
DESCRIPTION
"A collection of objects providing
environmental monitor information."
::= { rbnEnvMonMIBGroups 5 }
rbnEnvMonMIBNotificationGroupV2 NOTIFICATION-GROUP
NOTIFICATIONS { rbnFanStatusChange,
rbnPowerStatusChange
}
STATUS current
DESCRIPTION
"A collection of notifications providing
fan and power environmental monitor information."
::= { rbnEnvMonMIBGroups 6 }
rbnEnvMonFanSpeedObjectGroup OBJECT-GROUP
OBJECTS { rbnFanUnitDescr, rbnFanSpeedCurrent
}
STATUS current
DESCRIPTION
"A collection of objects providing fan speed
environmental monitor information."
::= { rbnEnvMonMIBGroups 7 }
rbnEnvMonEntityObjectGroup OBJECT-GROUP
OBJECTS { rbnEntityTempDescr, rbnEntityTempCurrent
}
STATUS current
DESCRIPTION
"A collection of objects providing fan speed
environmental monitor information."
::= { rbnEnvMonMIBGroups 8 }
rbnEnvMonMIBCompliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for the EnvMon MIB"
MODULE -- this module
GROUP rbnEnvMonMIBObjectGroup
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonMIBNotificationGroup
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
::= { rbnEnvMonMIBCompliances 1 }
rbnEnvMonMIBComplianceV2 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for the EnvMon MIB"
MODULE -- this module
GROUP rbnEnvMonMIBObjectGroup
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonMIBNotificationGroup
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonVoltageObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system voltages."
GROUP rbnEnvMonTempObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system temperatures."
::= { rbnEnvMonMIBCompliances 2 }
rbnEnvMonMIBComplianceV3 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for the EnvMon MIB"
MODULE -- this module
GROUP rbnEnvMonMIBObjectGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonMIBNotificationGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonVoltageObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system voltages."
GROUP rbnEnvMonTempObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system temperatures."
::= { rbnEnvMonMIBCompliances 3 }
rbnEnvMonMIBComplianceV4 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for the EnvMon MIB"
MODULE -- this module
GROUP rbnEnvMonMIBObjectGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonMIBNotificationGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonVoltageObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system voltages."
GROUP rbnEnvMonTempObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system temperatures."
GROUP rbnEnvMonFanSpeedObjectGroup
DESCRIPTION
"This group is mandatory for SNMP entities which are
capable of sensing fan speeds."
::= { rbnEnvMonMIBCompliances 4 }
rbnEnvMonMIBComplianceV5 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the EnvMon MIB"
MODULE -- this module
GROUP rbnEnvMonMIBObjectGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonMIBNotificationGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonVoltageObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system voltages."
GROUP rbnEnvMonFanSpeedObjectGroup
DESCRIPTION
"This group is mandatory for SNMP entities which are
capable of sensing fan speeds."
GROUP rbnEnvMonEntityObjectGroup
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities, also applicable to SSE
card and disks"
::= { rbnEnvMonMIBCompliances 5 }
END
|