diff options
Diffstat (limited to 'MIBS/ericsson/RBN-ENVMON-MIB')
| -rw-r--r-- | MIBS/ericsson/RBN-ENVMON-MIB | 790 |
1 files changed, 790 insertions, 0 deletions
diff --git a/MIBS/ericsson/RBN-ENVMON-MIB b/MIBS/ericsson/RBN-ENVMON-MIB new file mode 100644 index 0000000..c0a7da1 --- /dev/null +++ b/MIBS/ericsson/RBN-ENVMON-MIB @@ -0,0 +1,790 @@ +-- ***************************************************************** +-- RBN-ENVMON-MIB Environmental Monitor MIB +-- +-- Copyright (c) 1999-2007, 2010-2011 Ericsson AB +-- All rights reserved. +-- +-- ***************************************************************** + +RBN-ENVMON-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, + OBJECT-TYPE, + NOTIFICATION-TYPE, + Unsigned32, + Integer32 + FROM SNMPv2-SMI + DisplayString, + TruthValue, + TEXTUAL-CONVENTION + FROM SNMPv2-TC + MODULE-COMPLIANCE, + OBJECT-GROUP, + NOTIFICATION-GROUP + FROM SNMPv2-CONF + entPhysicalIndex + FROM ENTITY-MIB + rbnMgmt + FROM RBN-SMI; + +rbnEnvMonMIB MODULE-IDENTITY + LAST-UPDATED "201210030000Z" -- October 3, 2012 + ORGANIZATION "Ericsson AB." + CONTACT-INFO + " Ericsson AB. + + Postal: 100 Headquarters Dr. + San Jose, CA 95134 + USA + + Phone: +1 408 750 5000 + Fax: +1 408 750 5599 + + " + DESCRIPTION + "The MIB used to genericially manage Environmental + Monitor functionality on network devices." + + REVISION "201210030000Z" -- October 3, 2012 + DESCRIPTION + "Removed DISPLAY-HINT from RbnVoltage and RbnFanSpeed." + + REVISION "201101191800Z" -- Jan 19, 2011 + DESCRIPTION + "Update CONTACT-INFO & ORGANIZATION. " + + REVISION "201011110000Z" -- Nov 11, 2010 + DESCRIPTION + "Add new Table rbnEntityTempSensorTable. This will display + the TempSensor Details for all the entities. " + + REVISION "200601160000Z" -- January 16, 2006 + DESCRIPTION + "Add textual convention RbnFanSpeed. Add new OIDs: + rbnFanUnitID + rbnFanUnitDescr + rbnFanSpeedCurrent + rbnEnvMonFanSpeedObjectGroup + rbnEnvMonMIBComplianceV4 + " + REVISION "200206050000Z" -- June 5, 2002 + DESCRIPTION + "Update/correct CONTACT-INFO. Fix syntax errors on IMPORTS list, + ranges on Integer32, and size for DisplayString types. + Restore the incorrectly deprecated OIDs to current, since they + are still supported." + REVISION "200107250000Z" -- July 25, 2001 + DESCRIPTION + "Added new OIDs: + rbnFanStatus + rbnPowerStatus + rbnFanStatusChange + rbnPowerStatusChange + rbnEnvMonMIBObjectGroupV2 + rbnEnvMonMIBNotificationGroupV2 + rbnEnvMonMIBComplianceV3 + Deprecated the OIDs: + rbnFanFail + rbnPowerFail + rbnFanFailChange + rbnPowerFailChange + rbnEnvMonMIBObjectGroup + rbnEnvMonMIBNotificationGroup + rbnEnvMonMIBComplianceV2 + " + REVISION "200004240000Z" -- May 24, 2000 + DESCRIPTION + "Added voltage and temperature sensor tables." + + REVISION "199903100000Z" -- Mar 10, 1999 + DESCRIPTION + "Initial version." + ::= { rbnMgmt 4 } + +rbnEnvMonMIBNotifications OBJECT IDENTIFIER + ::= { rbnEnvMonMIB 0 } + +rbnEnvMonMIBObjects OBJECT IDENTIFIER + ::= { rbnEnvMonMIB 1 } + +rbnEnvMonMIBConformance OBJECT IDENTIFIER + ::= { rbnEnvMonMIB 2 } + + +-- Textual Conventions + +RbnVoltage ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Represents a voltage value. The value is millivolts. + For example, a voltage of 5.5V would be represented + by the value 5500." + SYNTAX Unsigned32 (0..50000) + +RbnTemperature ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d" + STATUS current + DESCRIPTION + "Represents a temperature, in degrees Celsius. In the + unlikely event that the temperature to be reported is + less than 0 degrees Celsius, a value of 0 will be + used. Likewise, if the temperature is greater than + 100, a value of 100 will be used." + SYNTAX Unsigned32 (0..100) + +RbnFanSpeed ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Represents a fan speed value in units of Revolutions Per + Minute(RPM)." + SYNTAX Unsigned32 + +-- MIB Objects + +rbnFanStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RbnFanStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains one row per fan test point. + Note that there is not necessarily a one-to-one + relationship between fan test points and fan + assemblies; a single test point may be used to + monitor the status of multiple fans." + ::= { rbnEnvMonMIBObjects 1 } + +rbnFanStatusEntry OBJECT-TYPE + SYNTAX RbnFanStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information about a particular fan test point" + INDEX { rbnFanIndex } + ::= { rbnFanStatusTable 1 } + +RbnFanStatusEntry ::= SEQUENCE { + rbnFanIndex Integer32, + rbnFanDescr DisplayString, + rbnFanFail TruthValue, + rbnFanStatus INTEGER +} + +rbnFanIndex OBJECT-TYPE + SYNTAX Integer32(1..2147483647) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index of a fan test point." + ::= { rbnFanStatusEntry 1 } + +rbnFanDescr OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The description of a fan test point. If an instance of + this object is associated with a single fan assembly, + then the value of this object should be the same as the + name by which the assembly is normally referenced. If + an instance is associated with multiple fan assemblies, + then the value of this object should contain the names + of all of the fan assemblies being monitored." + ::= { rbnFanStatusEntry 2 } + +rbnFanFail OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The status of a fan test point. If an instance of + this object has the value true, then a fan monitored + by the test point has failed. If an instance of + this object has the value false, then the fan (or fans) + monitored by the test point are operational." + ::= { rbnFanStatusEntry 3 } + +rbnFanStatus OBJECT-TYPE + SYNTAX INTEGER { + normal(1), + failed(2), + absent(3), + unknown(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The status of a fan test point. If an instance of + this object has the value normal, then the fan (or + fans) monitored by the test point is operational. If + an instance of this object has the value failed, then + the fan (or fans) monitored by the test point has + failed. If an instance of this object has the value + absent, then the fan (or fans) monitored by this test + point is not present. If an instance of this object has + the value unknown, then the test point is unable to + monitor the fan (or fans)." + ::= { rbnFanStatusEntry 4 } + +rbnPowerStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RbnPowerStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains one row per power test point. + Note that there is not necessarily a one-to-one + relationship between power test points and power + supply assemblies; a single test point may be used + to monitor the status of multiple power supplies." + ::= { rbnEnvMonMIBObjects 2 } + +rbnPowerStatusEntry OBJECT-TYPE + SYNTAX RbnPowerStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information about a particular power test point" + INDEX { rbnPowerIndex } + ::= { rbnPowerStatusTable 1 } + +RbnPowerStatusEntry ::= SEQUENCE { + rbnPowerIndex Integer32, + rbnPowerDescr DisplayString, + rbnPowerFail TruthValue, + rbnPowerStatus INTEGER +} + +rbnPowerIndex OBJECT-TYPE + SYNTAX Integer32(1..2147483647) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index of a power test point." + ::= { rbnPowerStatusEntry 1 } + +rbnPowerDescr OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The description of a power supply test point. If an + instance of this object is associated with a single + power supply assembly, then the value of this object + should be the same as the name by which the assembly + is normally referenced. If an instance is associated + with multiple power supply assemblies, then the value + of this object should contain the names of all of the + power supply assemblies being monitored." + ::= { rbnPowerStatusEntry 2 } + +rbnPowerFail OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The status of a power test point. If an instance of + this object has the value true, then a power supply + monitored by the test point has failed. If an instance + of this object has the value false, then the power + supply (or supplies) monitored by the test point are + operational." + ::= { rbnPowerStatusEntry 3 } + +rbnPowerStatus OBJECT-TYPE + SYNTAX INTEGER { + normal(1), + failed(2), + absent(3), + unknown(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The status of a power test point. If an instance of + this object has the value normal, then the power + supply (or supplies) monitored by the test point is + operational. If an instance of this object has the + value failed, then the power supply (or supplies) + monitored by the test point has failed. If an instance + of this object has the value absent, then the power + supply (or supplies) monitored by this test point is + not present. If an instance of this object has + the value unknown, then the test point is unable to + monitor the power supply (or supplies)." + ::= { rbnPowerStatusEntry 4 } + +rbnVoltageSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF RbnVoltageSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains one row per voltage test point. + Each physical entity (e.g. cards) in the system may + contain zero or more voltage test points." + ::= { rbnEnvMonMIBObjects 3 } + +rbnVoltageSensorEntry OBJECT-TYPE + SYNTAX RbnVoltageSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information about a particular voltage test point." + INDEX { entPhysicalIndex, rbnVoltageIndex } + ::= { rbnVoltageSensorTable 1 } + +RbnVoltageSensorEntry ::= SEQUENCE { + rbnVoltageIndex Integer32, + rbnVoltageDescr DisplayString, + rbnVoltageDesired RbnVoltage, + rbnVoltageCurrent RbnVoltage +} + +rbnVoltageIndex OBJECT-TYPE + SYNTAX Integer32(1..2147483647) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An arbitrary value which uniquely identifies a + voltage test point on a particular physical entity. + Index values for different test points are not + necessarily contiguous." + ::= { rbnVoltageSensorEntry 1 } + +rbnVoltageDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..48)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The description of a voltage test point. Typically + an instance of this object will hold a user-friendly + description of the physical entity and the level of + voltage being monitored by this test point." + ::= { rbnVoltageSensorEntry 2 } + +rbnVoltageDesired OBJECT-TYPE + SYNTAX RbnVoltage + UNITS "millivolts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The desired voltage level for this test point. If + the monitored voltage level (rbnVoltageCurrent) is + equal to this value, then the system is performing + as designed." + ::= { rbnVoltageSensorEntry 3 } + +rbnVoltageCurrent OBJECT-TYPE + SYNTAX RbnVoltage + UNITS "millivolts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current voltage level at this test point." + ::= { rbnVoltageSensorEntry 4 } + +rbnCpuTempSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF RbnCpuTempSensorEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "This table contains one row per CPU temperature + sensor. Each physical entity in the system may have + zero or more CPUs. Each of those CPUs that has a + temperature sensor will show up here." + ::= { rbnEnvMonMIBObjects 4 } + +rbnCpuTempSensorEntry OBJECT-TYPE + SYNTAX RbnCpuTempSensorEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "Information about a particular CPU temperature test + point." + INDEX { entPhysicalIndex, rbnCpuTempIndex } + ::= { rbnCpuTempSensorTable 1 } + +RbnCpuTempSensorEntry ::= SEQUENCE { + rbnCpuTempIndex Integer32, + rbnCpuTempDescr DisplayString, + rbnCpuTempCurrent RbnTemperature +} + +rbnCpuTempIndex OBJECT-TYPE + SYNTAX Integer32(1..2147483647) + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "An arbitrary value which uniquely identifies a CPU on + a particular physical entity. Index values for + different CPUs are not necessarily contiguous." + ::= { rbnCpuTempSensorEntry 1 } + +rbnCpuTempDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..48)) + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The description of a CPU temperature test + point. Typically an instance of this object will hold + a user-friendly description of the physical entity + and a description of the CPU being monitored by this + test point." + ::= { rbnCpuTempSensorEntry 2 } + +rbnCpuTempCurrent OBJECT-TYPE + SYNTAX RbnTemperature + UNITS "degrees" + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The current temperature of this CPU." + ::= { rbnCpuTempSensorEntry 3 } + +rbnFanSpeedTable OBJECT-TYPE + SYNTAX SEQUENCE OF RbnFanSpeedEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains one row per fan unit within a fan + test point." + ::= { rbnEnvMonMIBObjects 5 } + +rbnFanSpeedEntry OBJECT-TYPE + SYNTAX RbnFanSpeedEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information about a particular fan unit within a fan + test point." + INDEX { rbnFanIndex, rbnFanUnitID } + ::= { rbnFanSpeedTable 1 } + +RbnFanSpeedEntry ::= SEQUENCE { + rbnFanUnitID Integer32, + rbnFanUnitDescr DisplayString, + rbnFanSpeedCurrent RbnFanSpeed +} + +rbnFanUnitID OBJECT-TYPE + SYNTAX Integer32(1..2147483647) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is the fan identification number that describes the + specific location of the fan unit within a fan test point." + ::= { rbnFanSpeedEntry 1 } + +rbnFanUnitDescr OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The description of the fan unit within a fan test point." + ::= { rbnFanSpeedEntry 2 } + +rbnFanSpeedCurrent OBJECT-TYPE + SYNTAX RbnFanSpeed + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current speed of this fan unit." + ::= { rbnFanSpeedEntry 3 } + +rbnEntityTempSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF RbnEntityTempSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains one row per temperature + sensor on the physical entity." + ::= { rbnEnvMonMIBObjects 6 } + +rbnEntityTempSensorEntry OBJECT-TYPE + SYNTAX RbnEntityTempSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information about a particular temperature test + point." + INDEX { entPhysicalIndex, rbnEntityTempIndex } + ::= { rbnEntityTempSensorTable 1 } + +RbnEntityTempSensorEntry ::= SEQUENCE { + rbnEntityTempIndex Integer32, + rbnEntityTempDescr DisplayString, + rbnEntityTempCurrent RbnTemperature +} + +rbnEntityTempIndex OBJECT-TYPE + SYNTAX Integer32(1..2147483647) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An arbitrary value which uniquely identifies a + particular physical entity. Index values are + not necessarily contiguous." + ::= { rbnEntityTempSensorEntry 1 } + +rbnEntityTempDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..48)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The description of a temperature test + point. Typically an instance of this object will hold + a user-friendly description of the physical entity + being monitored by this test point." + ::= { rbnEntityTempSensorEntry 2 } + +rbnEntityTempCurrent OBJECT-TYPE + SYNTAX RbnTemperature + UNITS "degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current temperature of this entity in degrees Celsius." + ::= { rbnEntityTempSensorEntry 3 } + +-- Notifications + +rbnFanFailChange NOTIFICATION-TYPE + OBJECTS { rbnFanFail } + STATUS deprecated + DESCRIPTION + "A rbnFanFailChange notification signifies + that the value of an instance of rbnFanFail + has changed." + ::= { rbnEnvMonMIBNotifications 1 } + +rbnPowerFailChange NOTIFICATION-TYPE + OBJECTS { rbnPowerFail } + STATUS deprecated + DESCRIPTION + "A rbnPowerFailChange notification signifies + that the value of an instance of rbnPowerFail + has changed" + ::= { rbnEnvMonMIBNotifications 2 } + +rbnFanStatusChange NOTIFICATION-TYPE + OBJECTS { rbnFanStatus } + STATUS current + DESCRIPTION + "A rbnFanStatusChange notification signifies + that the value of an instance of rbnFanStatus + has changed." + ::= { rbnEnvMonMIBNotifications 3 } + +rbnPowerStatusChange NOTIFICATION-TYPE + OBJECTS { rbnPowerStatus } + STATUS current + DESCRIPTION + "A rbnPowerStatusChange notification signifies + that the value of an instance of rbnPowerStatus + has changed" + ::= { rbnEnvMonMIBNotifications 4 } + +-- Conformance Statements + +rbnEnvMonMIBGroups OBJECT IDENTIFIER + ::= { rbnEnvMonMIBConformance 1 } + +rbnEnvMonMIBCompliances OBJECT IDENTIFIER + ::= { rbnEnvMonMIBConformance 2 } + +rbnEnvMonMIBObjectGroup OBJECT-GROUP + OBJECTS { rbnFanDescr, rbnFanFail, + rbnPowerDescr, rbnPowerFail + } + STATUS deprecated + DESCRIPTION + "A collection of objects providing + environmental monitor information." + ::= { rbnEnvMonMIBGroups 1 } + +rbnEnvMonMIBNotificationGroup NOTIFICATION-GROUP + NOTIFICATIONS { rbnFanFailChange, + rbnPowerFailChange + } + STATUS deprecated + DESCRIPTION + "A collection of notifications providing + fan and power environmental monitor information." + ::= { rbnEnvMonMIBGroups 2 } + +rbnEnvMonVoltageObjectGroup OBJECT-GROUP + OBJECTS { rbnVoltageDescr, rbnVoltageDesired, + rbnVoltageCurrent + } + STATUS current + DESCRIPTION + "A collection of objects providing voltage + environmental monitor information." + ::= { rbnEnvMonMIBGroups 3 } + +rbnEnvMonTempObjectGroup OBJECT-GROUP + OBJECTS { rbnCpuTempDescr, rbnCpuTempCurrent + } + STATUS deprecated + DESCRIPTION + "A collection of objects providing temperature + environmental monitor information." + ::= { rbnEnvMonMIBGroups 4 } + +rbnEnvMonMIBObjectGroupV2 OBJECT-GROUP + OBJECTS { rbnFanDescr, rbnFanStatus, + rbnPowerDescr, rbnPowerStatus + } + STATUS current + DESCRIPTION + "A collection of objects providing + environmental monitor information." + ::= { rbnEnvMonMIBGroups 5 } + +rbnEnvMonMIBNotificationGroupV2 NOTIFICATION-GROUP + NOTIFICATIONS { rbnFanStatusChange, + rbnPowerStatusChange + } + STATUS current + DESCRIPTION + "A collection of notifications providing + fan and power environmental monitor information." + ::= { rbnEnvMonMIBGroups 6 } + +rbnEnvMonFanSpeedObjectGroup OBJECT-GROUP + OBJECTS { rbnFanUnitDescr, rbnFanSpeedCurrent + } + STATUS current + DESCRIPTION + "A collection of objects providing fan speed + environmental monitor information." + ::= { rbnEnvMonMIBGroups 7 } + +rbnEnvMonEntityObjectGroup OBJECT-GROUP + OBJECTS { rbnEntityTempDescr, rbnEntityTempCurrent + } + STATUS current + DESCRIPTION + "A collection of objects providing fan speed + environmental monitor information." + ::= { rbnEnvMonMIBGroups 8 } + +rbnEnvMonMIBCompliance MODULE-COMPLIANCE + STATUS obsolete + DESCRIPTION + "The compliance statement for the EnvMon MIB" + MODULE -- this module + GROUP rbnEnvMonMIBObjectGroup + DESCRIPTION + "This group is mandatory for devices which contain + Environmental Monitoring capabilities" + GROUP rbnEnvMonMIBNotificationGroup + DESCRIPTION + "This group is mandatory for devices which contain + Environmental Monitoring capabilities" + ::= { rbnEnvMonMIBCompliances 1 } + +rbnEnvMonMIBComplianceV2 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for the EnvMon MIB" + + MODULE -- this module + GROUP rbnEnvMonMIBObjectGroup + DESCRIPTION + "This group is mandatory for devices which contain + Environmental Monitoring capabilities" + GROUP rbnEnvMonMIBNotificationGroup + DESCRIPTION + "This group is mandatory for devices which contain + Environmental Monitoring capabilities" + GROUP rbnEnvMonVoltageObjectGroup + DESCRIPTION + "This group is mandatory for devices which are capable + of sensing system voltages." + GROUP rbnEnvMonTempObjectGroup + DESCRIPTION + "This group is mandatory for devices which are capable + of sensing system temperatures." + ::= { rbnEnvMonMIBCompliances 2 } + +rbnEnvMonMIBComplianceV3 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for the EnvMon MIB" + MODULE -- this module + GROUP rbnEnvMonMIBObjectGroupV2 + DESCRIPTION + "This group is mandatory for devices which contain + Environmental Monitoring capabilities" + GROUP rbnEnvMonMIBNotificationGroupV2 + DESCRIPTION + "This group is mandatory for devices which contain + Environmental Monitoring capabilities" + GROUP rbnEnvMonVoltageObjectGroup + DESCRIPTION + "This group is mandatory for devices which are capable + of sensing system voltages." + GROUP rbnEnvMonTempObjectGroup + DESCRIPTION + "This group is mandatory for devices which are capable + of sensing system temperatures." + ::= { rbnEnvMonMIBCompliances 3 } + +rbnEnvMonMIBComplianceV4 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for the EnvMon MIB" + MODULE -- this module + GROUP rbnEnvMonMIBObjectGroupV2 + DESCRIPTION + "This group is mandatory for devices which contain + Environmental Monitoring capabilities" + GROUP rbnEnvMonMIBNotificationGroupV2 + DESCRIPTION + "This group is mandatory for devices which contain + Environmental Monitoring capabilities" + GROUP rbnEnvMonVoltageObjectGroup + DESCRIPTION + "This group is mandatory for devices which are capable + of sensing system voltages." + GROUP rbnEnvMonTempObjectGroup + DESCRIPTION + "This group is mandatory for devices which are capable + of sensing system temperatures." + GROUP rbnEnvMonFanSpeedObjectGroup + DESCRIPTION + "This group is mandatory for SNMP entities which are + capable of sensing fan speeds." + ::= { rbnEnvMonMIBCompliances 4 } + + +rbnEnvMonMIBComplianceV5 MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for the EnvMon MIB" + MODULE -- this module + GROUP rbnEnvMonMIBObjectGroupV2 + DESCRIPTION + "This group is mandatory for devices which contain + Environmental Monitoring capabilities" + GROUP rbnEnvMonMIBNotificationGroupV2 + DESCRIPTION + "This group is mandatory for devices which contain + Environmental Monitoring capabilities" + GROUP rbnEnvMonVoltageObjectGroup + DESCRIPTION + "This group is mandatory for devices which are capable + of sensing system voltages." + GROUP rbnEnvMonFanSpeedObjectGroup + DESCRIPTION + "This group is mandatory for SNMP entities which are + capable of sensing fan speeds." + GROUP rbnEnvMonEntityObjectGroup + DESCRIPTION + "This group is mandatory for devices which contain + Environmental Monitoring capabilities, also applicable to SSE + card and disks" + + ::= { rbnEnvMonMIBCompliances 5 } + +END |