summaryrefslogtreecommitdiff
path: root/MIBS/planet/DIGIPDU-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/planet/DIGIPDU-MIB
downloadmibs-main.tar.gz
mibs-main.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/planet/DIGIPDU-MIB')
-rwxr-xr-xMIBS/planet/DIGIPDU-MIB3174
1 files changed, 3174 insertions, 0 deletions
diff --git a/MIBS/planet/DIGIPDU-MIB b/MIBS/planet/DIGIPDU-MIB
new file mode 100755
index 0000000..c912cfb
--- /dev/null
+++ b/MIBS/planet/DIGIPDU-MIB
@@ -0,0 +1,3174 @@
+--
+-- Copyright (C) 2014 All Rights Reserved.
+--
+
+ DIGIPDU-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ MODULE-IDENTITY, NOTIFICATION-TYPE,
+ OBJECT-TYPE, enterprises FROM SNMPv2-SMI
+ DisplayString FROM SNMPv2-TC
+ TRAP-TYPE FROM RFC-1215;
+
+ smart MODULE-IDENTITY
+ LAST-UPDATED "200904161627Z" -- April 16 2009
+ ORGANIZATION ""
+ CONTACT-INFO
+ ""
+
+ DESCRIPTION "This is the MIB module for the All DIGIPDU Device"
+ REVISION "200904161627Z" -- April 16 2009
+ DESCRIPTION "V1.00 for the DIGIPDU Device"
+ ::= { digipdu 3 }
+
+ digipdu OBJECT IDENTIFIER ::= { enterprises 10456 }
+
+--
+-- Product
+--
+
+ product OBJECT IDENTIFIER ::= { smart 1 }
+
+ productModel OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..50))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicate the Model of Device."
+ ::= { product 1 }
+
+ productPartNumber OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part number of this appliance as shown on the label."
+ ::= { product 2 }
+
+ productSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number of this appliance as shown on the label."
+ ::= { product 3 }
+
+ productFirmwareVersion OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The version of the firmware of this product."
+ ::= { product 4 }
+
+ productTemperatureKind OBJECT-TYPE
+ SYNTAX INTEGER(0..1)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Temperature Kind(0:CELSIUS, 1:FAHRENHEIT)."
+ ::= { product 11 }
+
+ productResetDetector OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Display the Nearest Operated Time of Reset Buttom."
+ ::= { product 21 }
+
+--
+-- Device Tables
+--
+
+ deviceTable OBJECT IDENTIFIER ::= { smart 2 }
+
+ deviceATSKind OBJECT-TYPE
+ SYNTAX INTEGER(1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device ATS Kind."
+ ::= { deviceTable 1 }
+
+ deviceInFeedTotal OBJECT-TYPE
+ SYNTAX INTEGER(1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Input Feed Total."
+ ::= { deviceTable 2 }
+
+ deviceInFeedKind OBJECT-TYPE
+ SYNTAX INTEGER(1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Input Feed Kind."
+ ::= { deviceTable 3 }
+
+ deviceInFeedBranch OBJECT-TYPE
+ SYNTAX INTEGER(1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Input Feed Kind."
+ ::= { deviceTable 4 }
+
+ deviceOutTotal OBJECT-TYPE
+ SYNTAX INTEGER(1..24)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Out Total."
+ ::= { deviceTable 5 }
+
+ deviceOutKind OBJECT-TYPE
+ SYNTAX INTEGER(1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Out Kind."
+ ::= { deviceTable 6 }
+
+ deviceInbuiltTempTotal OBJECT-TYPE
+ SYNTAX INTEGER(0..1)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Inbuilt Temperature Total."
+ ::= { deviceTable 7 }
+
+ deviceExtendTemperatureTotal OBJECT-TYPE
+ SYNTAX INTEGER(0..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Extend ENV Total."
+ ::= { deviceTable 8 }
+
+ deviceExtendRHTotal OBJECT-TYPE
+ SYNTAX INTEGER(0..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Extend ENV Total."
+ ::= { deviceTable 9 }
+
+ devicePDUTotal OBJECT-TYPE
+ SYNTAX INTEGER(1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU Total."
+ ::= { deviceTable 10 }
+
+ deviceInputTotal OBJECT-TYPE
+ SYNTAX INTEGER(1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Input Total."
+ ::= { deviceTable 11 }
+
+ deviceUPS OBJECT-TYPE
+ SYNTAX INTEGER{
+ no(0),
+ yes(1)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS."
+ ::= { deviceTable 12 }
+
+ deviceDaisyChain OBJECT-TYPE
+ SYNTAX INTEGER{
+ no(0),
+ yes(1)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Daisy Chain."
+ ::= { deviceTable 13 }
+
+ deviceUnitTotal OBJECT-TYPE
+ SYNTAX INTEGER(1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device Unit Total."
+ ::= { deviceTable 20 }
+
+--
+-- Device Unit Table
+--
+
+ deviceUnitTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DeviceUnitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of Device Unit."
+ ::= { deviceTable 21 }
+
+ deviceUnitEntry OBJECT-TYPE
+ SYNTAX DeviceUnitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for Device Unit table."
+ INDEX { deviceUnitIndex }
+ ::= { deviceUnitTable 1 }
+
+ DeviceUnitEntry ::= SEQUENCE {
+ deviceUnitIndex INTEGER,
+ deviceUnitStatus INTEGER,
+ deviceUnitInfeedTotal INTEGER,
+ deviceUnitOutTotal INTEGER
+ }
+
+ deviceUnitIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device Unit table index."
+ ::= { deviceUnitEntry 1 }
+
+ deviceUnitStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "status in the Device Unit."
+ ::= { deviceUnitEntry 2 }
+
+ deviceUnitInfeedTotal OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Infeed Total of Device Unit."
+ ::= { deviceUnitEntry 3 }
+
+ deviceUnitOutTotal OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Out Total of Device Unit."
+ ::= { deviceUnitEntry 4 }
+
+--
+-- peripheral Tables
+--
+
+ peripheralTables OBJECT IDENTIFIER ::= { smart 3 }
+
+--
+-- ATS Table
+--
+
+ aTSTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ATSEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of Auto Transfer Switch."
+ ::= { peripheralTables 1 }
+
+ aTSEntry OBJECT-TYPE
+ SYNTAX ATSEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for Input Feed table."
+ INDEX { aTSIndex }
+ ::= { aTSTable 1 }
+
+ ATSEntry ::= SEQUENCE {
+ aTSIndex INTEGER,
+ aTSStatus INTEGER,
+ aTSVoltage INTEGER,
+ aTSFrequency INTEGER
+ }
+
+ aTSIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Auto Transfer Switch table index."
+ ::= { aTSEntry 1 }
+
+ aTSStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "status in the Auto Transfer Switch."
+ ::= { aTSEntry 2 }
+
+ aTSVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Voltage of Auto Transfer Switch."
+ ::= { aTSEntry 3 }
+
+ aTSFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frequency of Auto Transfer Switch."
+ ::= { aTSEntry 4 }
+
+--
+-- InFeed Table
+--
+
+ inFeedTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF InFeedEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of Input Feed."
+ ::= { peripheralTables 2 }
+
+ inFeedEntry OBJECT-TYPE
+ SYNTAX InFeedEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for Input Feed table."
+ INDEX { inFeedIndex }
+ ::= { inFeedTable 1 }
+
+ InFeedEntry ::= SEQUENCE {
+ inFeedIndex INTEGER,
+ inFeedStatus INTEGER,
+ inFeedVoltage INTEGER,
+ inFeedFrequency INTEGER,
+ inFeedCurrent INTEGER,
+ inFeedPowerLoad INTEGER,
+ inFeedPowerFactor INTEGER,
+ inFeedPowerEnergy INTEGER,
+ inFeedOverLoad INTEGER,
+ inFeedHighWarning INTEGER,
+ inFeedLowWarning INTEGER,
+ inFeedBranch INTEGER,
+ inFeedBranch1Current INTEGER,
+ inFeedBranch1PowerLoad INTEGER,
+ inFeedBranch1PowerFactor INTEGER,
+ inFeedBranch1OverLoad INTEGER,
+ inFeedBranch1HighWarning INTEGER,
+ inFeedBranch1LowWarning INTEGER,
+ inFeedBranch2Current INTEGER,
+ inFeedBranch2PowerLoad INTEGER,
+ inFeedBranch2PowerFactor INTEGER,
+ inFeedBranch2OverLoad INTEGER,
+ inFeedBranch2HighWarning INTEGER,
+ inFeedBranch2LowWarning INTEGER
+ }
+
+ inFeedIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Input Feed table index."
+ ::= { inFeedEntry 1 }
+
+ inFeedStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "status in the Input Feed."
+ ::= { inFeedEntry 2 }
+
+ inFeedVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Voltage of Input Feed."
+ ::= { inFeedEntry 3 }
+
+ inFeedFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frequency of Input Feed."
+ ::= { inFeedEntry 4 }
+
+ inFeedCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total Current of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { inFeedEntry 5 }
+
+ inFeedPowerLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual value of power in the Input Feed."
+ ::= { inFeedEntry 6 }
+
+ inFeedPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual value of power factor in the Input Feed."
+ ::= { inFeedEntry 7 }
+
+
+ inFeedPowerEnergy OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual value of energy in the Input Feed."
+ ::= { inFeedEntry 8 }
+
+ inFeedOverLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "OverLoad of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { inFeedEntry 9 }
+
+ inFeedHighWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High Warning of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { inFeedEntry 10 }
+
+ inFeedLowWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low Warning of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { inFeedEntry 11 }
+
+ inFeedBranch OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { inFeedEntry 12 }
+
+ inFeedBranch1Current OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { inFeedEntry 13 }
+
+ inFeedBranch1PowerLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual value of power in the PDU."
+ ::= { inFeedEntry 14 }
+
+ inFeedBranch1PowerFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual value of power factor in the PDU."
+ ::= { inFeedEntry 15 }
+
+ inFeedBranch1OverLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "OverLoad of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { inFeedEntry 16 }
+
+ inFeedBranch1HighWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { inFeedEntry 17 }
+
+ inFeedBranch1LowWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { inFeedEntry 18 }
+
+ inFeedBranch2Current OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { inFeedEntry 19 }
+
+ inFeedBranch2PowerLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual value of power in the PDU."
+ ::= { inFeedEntry 20 }
+
+ inFeedBranch2PowerFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual value of power factor in the PDU."
+ ::= { inFeedEntry 21 }
+
+ inFeedBranch2OverLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "OverLoad of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { inFeedEntry 22 }
+
+ inFeedBranch2HighWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { inFeedEntry 23 }
+
+ inFeedBranch2LowWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { inFeedEntry 24 }
+
+--
+-- Outlet Table
+--
+
+ outTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of Outlet."
+ ::= { peripheralTables 3 }
+
+ outEntry OBJECT-TYPE
+ SYNTAX OutletEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for Outlet table."
+ INDEX { outIndex }
+ ::= { outTable 1 }
+
+ OutletEntry ::= SEQUENCE {
+ outIndex INTEGER,
+ outComputerStatus INTEGER,
+ outCurrentStatus INTEGER,
+ outSwitchStatus INTEGER,
+ outSwitchCtrl INTEGER,
+ outVoltage INTEGER,
+ outCurrent INTEGER,
+ outPowerFactor INTEGER,
+ outPowerLoad INTEGER,
+ outOverload INTEGER,
+ outHighWarning INTEGER,
+ outLowWarning INTEGER
+ }
+
+ outIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..24)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Out table index."
+ ::= { outEntry 1 }
+
+ outComputerStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Out computer status."
+ ::= { outEntry 2 }
+
+ outCurrentStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Out Current status."
+ ::= { outEntry 3 }
+
+ outSwitchStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ on(1),
+ off-act(2),
+ on-act(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This OID is provided for Outlet Status information.
+
+ '0' if the out is Switch Off.
+ '1' if the out is Switch On.
+ '2' if the out is Switch Off Acting.
+ '3' if the out is Switch On Acting.
+
+ "
+ ::= { outEntry 4 }
+
+ outSwitchCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0),
+ ctrl-on(1),
+ ctrl-off(2),
+ ctrl-reboot(3),
+ ctrl-on-off(4)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This OID is provided for Outlet Status information.
+
+ '0' if the out is None.
+ '1' Switch Ctrl On.
+ '2' Switch Ctrl Off.
+ '3' Switch Ctrl Reboot.
+ '4' Switch Ctrl On Off.
+
+ "
+ ::= { outEntry 5 }
+
+ outVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Voltage of Outlet."
+ ::= { outEntry 6 }
+
+ outCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current of Outlet(In tenths of amps, divide by 10 for value in amps)."
+ ::= { outEntry 7 }
+
+ outPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual value of power factor in the Outlet."
+ ::= { outEntry 8 }
+
+ outPowerLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual value of power in the Outlet."
+ ::= { outEntry 9 }
+
+ outOverload OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Overload of Outlet(In tenths of amps, divide by 10 for value in amps)."
+ ::= { outEntry 10 }
+
+ outHighWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High Warning of Outlet(In tenths of amps, divide by 10 for value in amps)."
+ ::= { outEntry 11 }
+
+ outLowWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low Warning of Outlet(In tenths of amps, divide by 10 for value in amps)."
+ ::= { outEntry 12 }
+
+--
+-- PDU Table
+--
+
+ pduTables OBJECT-TYPE
+ SYNTAX SEQUENCE OF PDUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of PDU."
+ ::= { peripheralTables 4 }
+
+ pduEntry OBJECT-TYPE
+ SYNTAX PDUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for PDU table."
+ INDEX { pduIndex }
+ ::= { pduTables 1 }
+
+ PDUEntry ::= SEQUENCE {
+ pduIndex INTEGER,
+ pduModel DisplayString,
+ pduMonitor INTEGER,
+ pduStatus INTEGER,
+ pduVoltage INTEGER,
+ pduFrequency INTEGER,
+ pduCurrent INTEGER,
+ pduPowerLoad INTEGER,
+ pduPowerFactor INTEGER,
+ pduPowerEnergy INTEGER,
+ pduOverload INTEGER,
+ pduHighWarning INTEGER,
+ pduLowWarning INTEGER,
+ pduBranch INTEGER,
+ pduBranch1Current INTEGER,
+ pduBranch1Overload INTEGER,
+ pduBranch1HighWarning INTEGER,
+ pduBranch1LowWarning INTEGER,
+ pduBranch2Current INTEGER,
+ pduBranch2Overload INTEGER,
+ pduBranch2HighWarning INTEGER,
+ pduBranch2LowWarning INTEGER
+ }
+
+ pduIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU table index."
+ ::= { pduEntry 1 }
+
+ pduModel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Now Power Data Log of PDU(In tenths of amps, divide by 10 for value in amps)."
+ ::= { pduEntry 2 }
+
+ pduMonitor OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0),
+ yes(1)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "PDU Monitor Status."
+ ::= { pduEntry 3 }
+
+ pduStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0),
+ yes(1),
+ warning(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU Connect Status."
+ ::= { pduEntry 4 }
+
+ pduVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Voltage of PDU."
+ ::= { pduEntry 5 }
+
+ pduFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frequency of PDU."
+ ::= { pduEntry 6 }
+
+ pduCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total Current of PDU(In tenths of amps, divide by 10 for value in amps)."
+ ::= { pduEntry 7 }
+
+ pduPowerLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual value of power in the PDU."
+ ::= { pduEntry 8 }
+
+ pduPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual value of power factor in the PDU."
+ ::= { pduEntry 9 }
+
+ pduPowerEnergy OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual value of power in the PDU."
+ ::= { pduEntry 10 }
+
+ pduOverload OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Overload of PDU(In tenths of amps, divide by 10 for value in amps)."
+ ::= { pduEntry 11 }
+
+ pduHighWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High Warning of PDU(In tenths of amps, divide by 10 for value in amps)."
+ ::= { pduEntry 12 }
+
+ pduLowWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High Warning of PDU(In tenths of amps, divide by 10 for value in amps)."
+ ::= { pduEntry 13 }
+
+ pduBranch OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { pduEntry 14 }
+
+ pduBranch1Current OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { pduEntry 15 }
+
+ pduBranch1Overload OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Overload of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { pduEntry 16 }
+
+ pduBranch1HighWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { pduEntry 17 }
+
+ pduBranch1LowWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { pduEntry 18 }
+
+ pduBranch2Current OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { pduEntry 19 }
+
+ pduBranch2Overload OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Overload of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { pduEntry 20 }
+
+ pduBranch2HighWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { pduEntry 21 }
+
+ pduBranch2LowWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)."
+ ::= { pduEntry 22 }
+
+--
+-- InbuiltTemperature Table
+--
+
+ inbuiltTemperatureTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF InbuiltTemperatureEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of Inbuilt Temperature Sensor."
+ ::= { peripheralTables 5 }
+
+ inbuiltTemperatureEntry OBJECT-TYPE
+ SYNTAX InbuiltTemperatureEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for Inbuilt Temperature Sensor table."
+ INDEX { inbuiltTemperatureIndex }
+ ::= { inbuiltTemperatureTable 1 }
+
+ InbuiltTemperatureEntry ::= SEQUENCE {
+ inbuiltTemperatureIndex INTEGER,
+ inbuiltTemperatureStatus INTEGER,
+ inbuiltTemperature INTEGER,
+ inbuiltTemperatureHighWarning INTEGER,
+ inbuiltTemperatureLowWarning INTEGER
+ }
+
+ inbuiltTemperatureIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for the Inbuilt Temperature Sensor table."
+ ::= { inbuiltTemperatureEntry 1 }
+
+ inbuiltTemperatureStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0),
+ yes(1)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Inbuilt Temperature Sensor Connect Status."
+ ::= { inbuiltTemperatureEntry 2 }
+
+ inbuiltTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Detected Temperature from Inbuilt Temperature Sensor."
+ ::= { inbuiltTemperatureEntry 3 }
+
+ inbuiltTemperatureHighWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High Warning Temperature from Inbuilt Temperature Sensor."
+ ::= { inbuiltTemperatureEntry 4 }
+
+ inbuiltTemperatureLowWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low Warning Temperature from Inbuilt Temperature Sensor."
+ ::= { inbuiltTemperatureEntry 5 }
+
+--
+-- ExtendTemperature Table
+--
+
+ extendTemperatureTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ExtendTemperatureEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of Extend Temperature Sensor."
+ ::= { peripheralTables 6 }
+
+ extendTemperatureEntry OBJECT-TYPE
+ SYNTAX ExtendTemperatureEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for Extend Temperature Sensor table."
+ INDEX { extendTemperatureIndex }
+ ::= { extendTemperatureTable 1 }
+
+ ExtendTemperatureEntry ::= SEQUENCE {
+ extendTemperatureIndex INTEGER,
+ extendTemperatureDeviceId INTEGER,
+ extendTemperaturePort INTEGER,
+ extendTemperatureMonitor INTEGER,
+ extendTemperatureStatus INTEGER,
+ extendTemperature INTEGER,
+ extendTemperatureHighWarning INTEGER,
+ extendTemperatureLowWarning INTEGER
+ }
+
+ extendTemperatureIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for the Extend Temperature Sensor table."
+ ::= { extendTemperatureEntry 1 }
+
+ extendTemperatureDeviceId OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Extend Temperature Monitor Status."
+ ::= { extendTemperatureEntry 2 }
+
+ extendTemperaturePort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Extend Temperature Monitor Status."
+ ::= { extendTemperatureEntry 3 }
+
+ extendTemperatureMonitor OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0),
+ yes(1)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Extend Temperature Monitor Status."
+ ::= { extendTemperatureEntry 4 }
+
+ extendTemperatureStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0),
+ yes(1)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Extend Temperature Sensor Connect Status."
+ ::= { extendTemperatureEntry 5 }
+
+ extendTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Detected Temperature from Inbuilt Temperature Sensor."
+ ::= { extendTemperatureEntry 6 }
+
+ extendTemperatureHighWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High Warning Temperature from Extend Temperature Sensor."
+ ::= { extendTemperatureEntry 7 }
+
+ extendTemperatureLowWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low Warning Temperature from Extend Temperature Sensor."
+ ::= { extendTemperatureEntry 8 }
+
+--
+-- extendRH Table
+--
+
+ extendRHTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ExtendRHEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of Extend RH Sensor."
+ ::= { peripheralTables 7 }
+
+ extendRHEntry OBJECT-TYPE
+ SYNTAX ExtendRHEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for Extend RH table."
+ INDEX { extendRHIndex }
+ ::= { extendRHTable 1 }
+
+ ExtendRHEntry ::= SEQUENCE {
+ extendRHIndex INTEGER,
+ extendRHDeviceId INTEGER,
+ extendRHPort INTEGER,
+ extendRHMonitor INTEGER,
+ extendRHStatus INTEGER,
+ extendRH INTEGER,
+ extendRHHighWarning INTEGER,
+ extendRHLowWarning INTEGER
+ }
+
+ extendRHIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for the Extend RH Sensor table."
+ ::= { extendRHEntry 1 }
+
+ extendRHDeviceId OBJECT-TYPE
+ SYNTAX INTEGER (0..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for the Extend RH Sensor table."
+ ::= { extendRHEntry 2 }
+
+ extendRHPort OBJECT-TYPE
+ SYNTAX INTEGER (0..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for the Extend RH Sensor table."
+ ::= { extendRHEntry 3 }
+
+ extendRHMonitor OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0),
+ yes(1)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Extend RH Monitor Status."
+ ::= { extendRHEntry 4 }
+
+ extendRHStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0),
+ yes(1)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Extend RH Sensor Connect Status."
+ ::= { extendRHEntry 5 }
+
+ extendRH OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Detected RH from Inbuilt Temperature Sensor."
+ ::= { extendRHEntry 6 }
+
+ extendRHHighWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High Warning RH from Extend Temperature Sensor."
+ ::= { extendRHEntry 7 }
+
+ extendRHLowWarning OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low Warning RH from Extend Temperature Sensor."
+ ::= { extendRHEntry 8 }
+
+--
+-- Input Table
+--
+
+ inputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF InputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of Input."
+ ::= { peripheralTables 8 }
+
+ inputEntry OBJECT-TYPE
+ SYNTAX InputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for Input table."
+ INDEX { inputIndex }
+ ::= { inputTable 1 }
+
+ InputEntry ::= SEQUENCE {
+ inputIndex INTEGER,
+ inputStatus INTEGER,
+ inputState INTEGER,
+ inputTimeout INTEGER,
+ inputDefault INTEGER,
+ inputDetectTime DisplayString
+}
+
+ inputIndex OBJECT-TYPE
+ SYNTAX INTEGER (1)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for Input table."
+ ::= { inputEntry 1 }
+
+ inputStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This OID is provided for Input Status.
+ '0' NORMAL.
+ '1' WARNING.
+ '2' TIMEOUT.
+ "
+ ::= { inputEntry 2 }
+
+ inputState OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This OID is provided for Input Default.
+ '0' NORMAL_CLOSE.
+ '1' NORMAL_OPEN.
+ "
+ ::= { inputEntry 3 }
+
+ inputTimeout OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TimeOut of Input Status."
+ ::= { inputEntry 4 }
+
+ inputDefault OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This OID is provided for Input Default.
+ '0' NORMAL_CLOSE.
+ '1' NORMAL_OPEN.
+ "
+ ::= { inputEntry 5 }
+
+ inputDetectTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Detect the nearest Changed Time of Input Status."
+ ::= { inputEntry 6 }
+
+--
+-- RFID reader
+--
+
+ rfidReader OBJECT IDENTIFIER ::= { peripheralTables 9 }
+
+ rfidCardNum OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "RFID Card Number."
+ ::= { rfidReader 1 }
+
+ rfidDetectTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Nearest Time to detect RFID Card."
+ ::= { rfidReader 2 }
+
+--
+-- UPS
+--
+
+ uPS OBJECT IDENTIFIER ::= { peripheralTables 10 }
+
+ uPSModel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Model."
+ ::= { uPS 1 }
+
+ uPSConnectStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Connect Status."
+ ::= { uPS 2 }
+
+ uPSFirmware OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Firmware."
+ ::= { uPS 3 }
+
+ uPSSerial OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Serial."
+ ::= { uPS 4 }
+
+ uPSTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Temperature."
+ ::= { uPS 5 }
+
+ uPSInputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Input Voltage."
+ ::= { uPS 6 }
+
+ uPSOutputOnBattery OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Output On Battery."
+ ::= { uPS 7 }
+
+ uPSOutputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Output Voltage."
+ ::= { uPS 8 }
+
+ uPSOutputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Output Voltage."
+ ::= { uPS 9 }
+
+ uPSOutputCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Output Current."
+ ::= { uPS 10 }
+
+ uPSOutputLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Output Load."
+ ::= { uPS 11 }
+
+ uPSOutputOverload OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Output Overload."
+ ::= { uPS 12 }
+
+ uPSBatteryDate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Battery Date."
+ ::= { uPS 13 }
+
+ uPSBatteryVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Battery Voltage."
+ ::= { uPS 14 }
+
+ uPSBatteryLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Battery Level."
+ ::= { uPS 15 }
+
+ uPSBatteryRunTime OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Battery RunTime."
+ ::= { uPS 16 }
+
+ uPSBatteryLow OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Battery Low."
+ ::= { uPS 17 }
+
+ uPSBatteryReplace OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS Battery Need Replace."
+ ::= { uPS 18 }
+
+ uPSUARTId OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UPS UART Id."
+ ::= { uPS 19 }
+
+--
+-- MIC Detect
+--
+
+ micDetec OBJECT IDENTIFIER ::= { peripheralTables 11 }
+
+ micDetectTimes OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "MIC Detect Times."
+ ::= { micDetec 1 }
+
+ micDetectPeriod OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "MIC Detect Period."
+ ::= { micDetec 2 }
+
+ micLastDetectTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "MIC Detect Detect Time."
+ ::= { micDetec 3 }
+
+--
+-- Vibration Detect
+--
+
+ vibrationDetec OBJECT IDENTIFIER ::= { peripheralTables 12 }
+
+ vibrationDetectTimes OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Vibration Detect Times."
+ ::= { vibrationDetec 1 }
+
+ vibrationDetectPeriod OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Vibration Detect Period."
+ ::= { vibrationDetec 2 }
+
+ vibrationLastDetectTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Vibration Detect Detect Time."
+ ::= { vibrationDetec 3 }
+
+ dataLogTable OBJECT IDENTIFIER ::= { smart 4 }
+
+--
+-- Input Feed Data Table
+--
+
+ inFeedDataList OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Input Feed Data List."
+ ::= { dataLogTable 1 }
+
+--
+-- Outlet Table
+--
+
+ outDataList OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Outlet Data List."
+ ::= { dataLogTable 2 }
+
+--
+-- PDU Table
+--
+
+ pduDataList OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU Data List."
+ ::= { dataLogTable 3 }
+
+--
+-- Enterprise Traps
+--
+ smartTraps OBJECT IDENTIFIER ::= { smart 100 }
+
+ trap OBJECT IDENTIFIER ::= { smartTraps 1 }
+ -- the 0 is for V1 compatibility
+
+ arg OBJECT IDENTIFIER ::= { smartTraps 2 }
+
+ trapArg1 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicate the Trap Arg1."
+ ::= { arg 1 }
+
+ trapArg2 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicate the Trap Arg2."
+ ::= { arg 2 }
+
+ trapArg3 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicate the Trap Arg3."
+ ::= { arg 3 }
+
+ trapArg4 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicate the Trap Arg4."
+ ::= { arg 4 }
+
+ trapArg5 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicate the Trap Arg5."
+ ::= { arg 5 }
+
+ trapArg6 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicate the Trap Arg6."
+ ::= { arg 6 }
+
+ trapArg7 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicate the Trap Arg7."
+ ::= { arg 7 }
+
+ trapArg8 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicate the Trap Arg8."
+ ::= { arg 8 }
+
+ trapArg9 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicate the Trap Arg9."
+ ::= { arg 9 }
+
+ testTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1
+ }
+ STATUS current
+ DESCRIPTION
+ "testData"
+ ::= { trap 1 }
+
+ -- Input Feed Traps
+
+ inFeedOverloadTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ inFeedIndex,
+ inFeedStatus,
+ inFeedCurrent,
+ inFeedOverload
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 101 }
+
+ inFeedHighCurrentTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ inFeedIndex,
+ inFeedStatus,
+ inFeedCurrent,
+ inFeedHighWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 102 }
+
+ inFeedLowCurrentTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ inFeedIndex,
+ inFeedStatus,
+ inFeedCurrent,
+ inFeedHighWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 103 }
+
+ inFeedBranchOverloadTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ inFeedIndex,
+ BranchIndex,
+ inFeedStatus,
+ inFeedCurrent,
+ inFeedOverload
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 104 }
+
+ inFeedBranchHighCurrentTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ inFeedIndex,
+ BranchIndex,
+ inFeedStatus,
+ inFeedCurrent,
+ inFeedHighWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 105 }
+
+ inFeedBranchLowCurrentTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ inFeedIndex,
+ BranchIndex,
+ inFeedStatus,
+ inFeedCurrent,
+ inFeedHighWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 106 }
+
+ outWebOperationTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3
+ }
+ STATUS current
+ DESCRIPTION
+ "Outlet on/off change event. If enabled, this trap is sent
+ when the outStatus changes from any 'on' state ('on',
+ 'onWait', 'onError', or 'onFuse') to any 'off' state ('off',
+ 'offWait', 'offError', or 'offFuse'), and vice-versa."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 201 }
+
+ outPanelOperationTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3
+ }
+ STATUS current
+ DESCRIPTION
+ "Outlet on/off change event. If enabled, this trap is sent
+ when the outStatus changes from any 'on' state ('on',
+ 'onWait', 'onError', or 'onFuse') to any 'off' state ('off',
+ 'offWait', 'offError', or 'offFuse'), and vice-versa."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 202 }
+
+ outAPIOperationTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3
+ }
+ STATUS current
+ DESCRIPTION
+ "Outlet on/off change event. If enabled, this trap is sent
+ when the outStatus changes from any 'on' state ('on',
+ 'onWait', 'onError', or 'onFuse') to any 'off' state ('off',
+ 'offWait', 'offError', or 'offFuse'), and vice-versa."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 203 }
+
+ outScheduleTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5,
+ trapArg6,
+ trapArg7,
+ trapArg8,
+ trapArg9
+ }
+ STATUS current
+ DESCRIPTION
+ "Outlet on/off change event. If enabled, this trap is sent
+ when the outStatus changes from any 'on' state ('on',
+ 'onWait', 'onError', or 'onFuse') to any 'off' state ('off',
+ 'offWait', 'offError', or 'offFuse'), and vice-versa."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 211 }
+
+ outScheduleErrorTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5,
+ trapArg6,
+ trapArg7
+ }
+ STATUS current
+ DESCRIPTION
+ "Outlet on/off change event. If enabled, this trap is sent
+ when the outStatus changes from any 'on' state ('on',
+ 'onWait', 'onError', or 'onFuse') to any 'off' state ('off',
+ 'offWait', 'offError', or 'offFuse'), and vice-versa."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 212 }
+
+ outPingTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4
+ }
+ STATUS current
+ DESCRIPTION
+ "Outlet on/off change event. If enabled, this trap is sent
+ when the outStatus changes from any 'on' state ('on',
+ 'onWait', 'onError', or 'onFuse') to any 'off' state ('off',
+ 'offWait', 'offError', or 'offFuse'), and vice-versa."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 221 }
+
+ outPingRebootTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4
+ }
+ STATUS current
+ DESCRIPTION
+ "Outlet on/off change event. If enabled, this trap is sent
+ when the outStatus changes from any 'on' state ('on',
+ 'onWait', 'onError', or 'onFuse') to any 'off' state ('off',
+ 'offWait', 'offError', or 'offFuse'), and vice-versa."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 222 }
+
+ outOverloadTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ outIndex,
+ outCurrentStatus,
+ outCurrent,
+ outHighWarning
+ Outlet load event. If enabled, this trap is sent when the
+ outLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the outLoadStatus
+ remains in an error state. If the outLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error outLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 231 }
+
+ outHighCurrentTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ outIndex,
+ outCurrentStatus,
+ outCurrent,
+ outHighWarning
+ Outlet load event. If enabled, this trap is sent when the
+ outLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the outLoadStatus
+ remains in an error state. If the outLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error outLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 232 }
+
+ outLowCurrentTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ outIndex,
+ outCurrentStatus,
+ outCurrent,
+ outLowWarning
+ Outlet load event. If enabled, this trap is sent when the
+ outLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the outLoadStatus
+ remains in an error state. If the outLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error outLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 233 }
+
+ outConditionCtrlTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ outIndex,
+ outCurrentStatus,
+ outCurrent,
+ outLowWarning
+ Outlet load event. If enabled, this trap is sent when the
+ outLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the outLoadStatus
+ remains in an error state. If the outLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error outLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 241 }
+
+ outUPSACFaultOffTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ value
+ Outlet load event. If enabled, this trap is sent when the
+ outLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the outLoadStatus
+ remains in an error state. If the outLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error outLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 311 }
+
+ outUPSBatteryLevelOffTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ value
+ Outlet load event. If enabled, this trap is sent when the
+ outLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the outLoadStatus
+ remains in an error state. If the outLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error outLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 312 }
+
+ outUPSBatteryLowOffTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ value
+ Outlet load event. If enabled, this trap is sent when the
+ outLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the outLoadStatus
+ remains in an error state. If the outLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error outLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 313 }
+
+ outUPSACRecoveryOnTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ value
+ Outlet load event. If enabled, this trap is sent when the
+ outLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the outLoadStatus
+ remains in an error state. If the outLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error outLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 314 }
+
+ outUPSBatteryLevelOnTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ value
+ Outlet load event. If enabled, this trap is sent when the
+ outLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the outLoadStatus
+ remains in an error state. If the outLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error outLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 315 }
+
+ outUPSBatteryLowRecoveryOnTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ value
+ Outlet load event. If enabled, this trap is sent when the
+ outLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the outLoadStatus
+ remains in an error state. If the outLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error outLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 316 }
+
+ pduConnectTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ PDUIndex,
+ PDUConnectStatus
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 401 }
+
+ pduOverloadTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ PDUIndex,
+ PDUStatus,
+ PDUCurrent,
+ PDUOverload
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 402 }
+
+ pduHighCurrentTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ PDUIndex,
+ PDUStatus,
+ PDUCurrent,
+ PDUHighWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 403 }
+
+ pduLowCurrentTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ PDUIndex,
+ PDUStatus,
+ PDUCurrent,
+ PDUHighWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 404 }
+
+ pduBranchOverloadTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ PDUIndex,
+ BranchIndex,
+ PDUStatus,
+ PDUCurrent,
+ PDUOverload
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 405 }
+
+ pduBranchHighCurrentTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ PDUIndex,
+ BranchIndex,
+ PDUStatus,
+ PDUCurrent,
+ PDUHighWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 406 }
+
+ pduBranchLowCurrentTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ PDUIndex,
+ BranchIndex,
+ PDUStatus,
+ PDUCurrent,
+ PDUHighWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 407 }
+
+ inbuiltTemperatureHighTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ InTempId,
+ InTempStatus,
+ InTempTemperature,
+ InTempTemperatureWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 501 }
+
+ inbuiltTemperatureLowTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ InTempId,
+ InTempStatus,
+ InTempTemperature,
+ InTempTemperatureWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 502 }
+
+ envConnectTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ ENVIndex,
+ ENVConnectStatus
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 511 }
+
+ envTemperatureConnectTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ ENVIndex,
+ ENVConnectStatus
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 512 }
+
+ envTemperatureHighTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5,
+ trapArg6
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ EnvId,
+ EnvStatus,
+ EnvTemperature,
+ EnvTemperatureWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 513 }
+
+ envTemperatureLowTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5,
+ trapArg6
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ EnvId,
+ EnvStatus,
+ EnvTemperature,
+ EnvTemperatureWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 514 }
+
+ envRHConnectTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ EnvId,
+ EnvStatus,
+ EnvRH,
+ EnvRHWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 515 }
+
+ envRHHighTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ EnvId,
+ EnvStatus,
+ EnvRH,
+ EnvRHWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 516 }
+
+ envRHLowTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4,
+ trapArg5
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ EnvId,
+ EnvStatus,
+ EnvRH,
+ EnvRHWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 517 }
+
+ inputTimeOutTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ EnvId,
+ EnvStatus,
+ EnvTemperature,
+ EnvTemperatureWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 601 }
+
+ inputTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2,
+ trapArg3,
+ trapArg4
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ deviceIndex,
+ EnvId,
+ EnvStatus,
+ EnvTemperature,
+ EnvTemperatureWarning
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 602 }
+
+ upsConnectTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ Model,
+ ConnectStatus
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 701 }
+
+ upsOnBatteryTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ Model,
+ ConnectStatus
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 702 }
+
+ upsOverloadTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ Model,
+ ConnectStatus
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 703 }
+
+ upsBatteryLowTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ Model,
+ ConnectStatus
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 704 }
+
+ upsBatteryReplace NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ Model,
+ ConnectStatus
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 705 }
+
+ daisyChainConnectTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ Model,
+ ConnectStatus
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 801 }
+
+ micDetectOccurTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ Model,
+ ConnectStatus
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 901 }
+
+ vibrationDetectOccurTrap NOTIFICATION-TYPE
+ OBJECTS {
+ trapArg1,
+ trapArg2
+ }
+ STATUS current
+ DESCRIPTION
+ "
+ Model,
+ ConnectStatus
+ Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#SUMMARY "The appliance is rebooting. Command issued by user: %s."
+ --#ARGUMENTS { 0 }
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY "Status Events"
+ --NAME "Appliance Rebooting"
+ --SHORT "appliance rebooting"
+ --EVENT evt_reboot
+ --% TrapTypeEnum=15
+ ::= { trap 902 }
+
+END