From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/planet/DIGIPDU-MIB | 3174 +++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 3174 insertions(+) create mode 100755 MIBS/planet/DIGIPDU-MIB (limited to 'MIBS/planet/DIGIPDU-MIB') diff --git a/MIBS/planet/DIGIPDU-MIB b/MIBS/planet/DIGIPDU-MIB new file mode 100755 index 0000000..c912cfb --- /dev/null +++ b/MIBS/planet/DIGIPDU-MIB @@ -0,0 +1,3174 @@ +-- +-- Copyright (C) 2014 All Rights Reserved. +-- + + DIGIPDU-MIB DEFINITIONS ::= BEGIN + + IMPORTS + MODULE-IDENTITY, NOTIFICATION-TYPE, + OBJECT-TYPE, enterprises FROM SNMPv2-SMI + DisplayString FROM SNMPv2-TC + TRAP-TYPE FROM RFC-1215; + + smart MODULE-IDENTITY + LAST-UPDATED "200904161627Z" -- April 16 2009 + ORGANIZATION "" + CONTACT-INFO + "" + + DESCRIPTION "This is the MIB module for the All DIGIPDU Device" + REVISION "200904161627Z" -- April 16 2009 + DESCRIPTION "V1.00 for the DIGIPDU Device" + ::= { digipdu 3 } + + digipdu OBJECT IDENTIFIER ::= { enterprises 10456 } + +-- +-- Product +-- + + product OBJECT IDENTIFIER ::= { smart 1 } + + productModel OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..50)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicate the Model of Device." + ::= { product 1 } + + productPartNumber OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The part number of this appliance as shown on the label." + ::= { product 2 } + + productSerialNumber OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The serial number of this appliance as shown on the label." + ::= { product 3 } + + productFirmwareVersion OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The version of the firmware of this product." + ::= { product 4 } + + productTemperatureKind OBJECT-TYPE + SYNTAX INTEGER(0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Temperature Kind(0:CELSIUS, 1:FAHRENHEIT)." + ::= { product 11 } + + productResetDetector OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Display the Nearest Operated Time of Reset Buttom." + ::= { product 21 } + +-- +-- Device Tables +-- + + deviceTable OBJECT IDENTIFIER ::= { smart 2 } + + deviceATSKind OBJECT-TYPE + SYNTAX INTEGER(1..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Device ATS Kind." + ::= { deviceTable 1 } + + deviceInFeedTotal OBJECT-TYPE + SYNTAX INTEGER(1..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Input Feed Total." + ::= { deviceTable 2 } + + deviceInFeedKind OBJECT-TYPE + SYNTAX INTEGER(1..4) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Input Feed Kind." + ::= { deviceTable 3 } + + deviceInFeedBranch OBJECT-TYPE + SYNTAX INTEGER(1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Input Feed Kind." + ::= { deviceTable 4 } + + deviceOutTotal OBJECT-TYPE + SYNTAX INTEGER(1..24) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Out Total." + ::= { deviceTable 5 } + + deviceOutKind OBJECT-TYPE + SYNTAX INTEGER(1..4) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Out Kind." + ::= { deviceTable 6 } + + deviceInbuiltTempTotal OBJECT-TYPE + SYNTAX INTEGER(0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Inbuilt Temperature Total." + ::= { deviceTable 7 } + + deviceExtendTemperatureTotal OBJECT-TYPE + SYNTAX INTEGER(0..6) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Extend ENV Total." + ::= { deviceTable 8 } + + deviceExtendRHTotal OBJECT-TYPE + SYNTAX INTEGER(0..4) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Extend ENV Total." + ::= { deviceTable 9 } + + devicePDUTotal OBJECT-TYPE + SYNTAX INTEGER(1..8) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "PDU Total." + ::= { deviceTable 10 } + + deviceInputTotal OBJECT-TYPE + SYNTAX INTEGER(1..8) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Input Total." + ::= { deviceTable 11 } + + deviceUPS OBJECT-TYPE + SYNTAX INTEGER{ + no(0), + yes(1)} + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS." + ::= { deviceTable 12 } + + deviceDaisyChain OBJECT-TYPE + SYNTAX INTEGER{ + no(0), + yes(1)} + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Daisy Chain." + ::= { deviceTable 13 } + + deviceUnitTotal OBJECT-TYPE + SYNTAX INTEGER(1..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Device Unit Total." + ::= { deviceTable 20 } + +-- +-- Device Unit Table +-- + + deviceUnitTable OBJECT-TYPE + SYNTAX SEQUENCE OF DeviceUnitEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of Device Unit." + ::= { deviceTable 21 } + + deviceUnitEntry OBJECT-TYPE + SYNTAX DeviceUnitEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Row definition for Device Unit table." + INDEX { deviceUnitIndex } + ::= { deviceUnitTable 1 } + + DeviceUnitEntry ::= SEQUENCE { + deviceUnitIndex INTEGER, + deviceUnitStatus INTEGER, + deviceUnitInfeedTotal INTEGER, + deviceUnitOutTotal INTEGER + } + + deviceUnitIndex OBJECT-TYPE + SYNTAX INTEGER(1..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Device Unit table index." + ::= { deviceUnitEntry 1 } + + deviceUnitStatus OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "status in the Device Unit." + ::= { deviceUnitEntry 2 } + + deviceUnitInfeedTotal OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Infeed Total of Device Unit." + ::= { deviceUnitEntry 3 } + + deviceUnitOutTotal OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Out Total of Device Unit." + ::= { deviceUnitEntry 4 } + +-- +-- peripheral Tables +-- + + peripheralTables OBJECT IDENTIFIER ::= { smart 3 } + +-- +-- ATS Table +-- + + aTSTable OBJECT-TYPE + SYNTAX SEQUENCE OF ATSEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of Auto Transfer Switch." + ::= { peripheralTables 1 } + + aTSEntry OBJECT-TYPE + SYNTAX ATSEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Row definition for Input Feed table." + INDEX { aTSIndex } + ::= { aTSTable 1 } + + ATSEntry ::= SEQUENCE { + aTSIndex INTEGER, + aTSStatus INTEGER, + aTSVoltage INTEGER, + aTSFrequency INTEGER + } + + aTSIndex OBJECT-TYPE + SYNTAX INTEGER(1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Auto Transfer Switch table index." + ::= { aTSEntry 1 } + + aTSStatus OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "status in the Auto Transfer Switch." + ::= { aTSEntry 2 } + + aTSVoltage OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Voltage of Auto Transfer Switch." + ::= { aTSEntry 3 } + + aTSFrequency OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frequency of Auto Transfer Switch." + ::= { aTSEntry 4 } + +-- +-- InFeed Table +-- + + inFeedTable OBJECT-TYPE + SYNTAX SEQUENCE OF InFeedEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of Input Feed." + ::= { peripheralTables 2 } + + inFeedEntry OBJECT-TYPE + SYNTAX InFeedEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Row definition for Input Feed table." + INDEX { inFeedIndex } + ::= { inFeedTable 1 } + + InFeedEntry ::= SEQUENCE { + inFeedIndex INTEGER, + inFeedStatus INTEGER, + inFeedVoltage INTEGER, + inFeedFrequency INTEGER, + inFeedCurrent INTEGER, + inFeedPowerLoad INTEGER, + inFeedPowerFactor INTEGER, + inFeedPowerEnergy INTEGER, + inFeedOverLoad INTEGER, + inFeedHighWarning INTEGER, + inFeedLowWarning INTEGER, + inFeedBranch INTEGER, + inFeedBranch1Current INTEGER, + inFeedBranch1PowerLoad INTEGER, + inFeedBranch1PowerFactor INTEGER, + inFeedBranch1OverLoad INTEGER, + inFeedBranch1HighWarning INTEGER, + inFeedBranch1LowWarning INTEGER, + inFeedBranch2Current INTEGER, + inFeedBranch2PowerLoad INTEGER, + inFeedBranch2PowerFactor INTEGER, + inFeedBranch2OverLoad INTEGER, + inFeedBranch2HighWarning INTEGER, + inFeedBranch2LowWarning INTEGER + } + + inFeedIndex OBJECT-TYPE + SYNTAX INTEGER(1..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Input Feed table index." + ::= { inFeedEntry 1 } + + inFeedStatus OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "status in the Input Feed." + ::= { inFeedEntry 2 } + + inFeedVoltage OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Voltage of Input Feed." + ::= { inFeedEntry 3 } + + inFeedFrequency OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frequency of Input Feed." + ::= { inFeedEntry 4 } + + inFeedCurrent OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total Current of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { inFeedEntry 5 } + + inFeedPowerLoad OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power in the Input Feed." + ::= { inFeedEntry 6 } + + inFeedPowerFactor OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power factor in the Input Feed." + ::= { inFeedEntry 7 } + + + inFeedPowerEnergy OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of energy in the Input Feed." + ::= { inFeedEntry 8 } + + inFeedOverLoad OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "OverLoad of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { inFeedEntry 9 } + + inFeedHighWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High Warning of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { inFeedEntry 10 } + + inFeedLowWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low Warning of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { inFeedEntry 11 } + + inFeedBranch OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { inFeedEntry 12 } + + inFeedBranch1Current OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { inFeedEntry 13 } + + inFeedBranch1PowerLoad OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power in the PDU." + ::= { inFeedEntry 14 } + + inFeedBranch1PowerFactor OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power factor in the PDU." + ::= { inFeedEntry 15 } + + inFeedBranch1OverLoad OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "OverLoad of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { inFeedEntry 16 } + + inFeedBranch1HighWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { inFeedEntry 17 } + + inFeedBranch1LowWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { inFeedEntry 18 } + + inFeedBranch2Current OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { inFeedEntry 19 } + + inFeedBranch2PowerLoad OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power in the PDU." + ::= { inFeedEntry 20 } + + inFeedBranch2PowerFactor OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power factor in the PDU." + ::= { inFeedEntry 21 } + + inFeedBranch2OverLoad OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "OverLoad of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { inFeedEntry 22 } + + inFeedBranch2HighWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { inFeedEntry 23 } + + inFeedBranch2LowWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { inFeedEntry 24 } + +-- +-- Outlet Table +-- + + outTable OBJECT-TYPE + SYNTAX SEQUENCE OF OutletEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of Outlet." + ::= { peripheralTables 3 } + + outEntry OBJECT-TYPE + SYNTAX OutletEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Row definition for Outlet table." + INDEX { outIndex } + ::= { outTable 1 } + + OutletEntry ::= SEQUENCE { + outIndex INTEGER, + outComputerStatus INTEGER, + outCurrentStatus INTEGER, + outSwitchStatus INTEGER, + outSwitchCtrl INTEGER, + outVoltage INTEGER, + outCurrent INTEGER, + outPowerFactor INTEGER, + outPowerLoad INTEGER, + outOverload INTEGER, + outHighWarning INTEGER, + outLowWarning INTEGER + } + + outIndex OBJECT-TYPE + SYNTAX INTEGER(1..24) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Out table index." + ::= { outEntry 1 } + + outComputerStatus OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Out computer status." + ::= { outEntry 2 } + + outCurrentStatus OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Out Current status." + ::= { outEntry 3 } + + outSwitchStatus OBJECT-TYPE + SYNTAX INTEGER { + off(0), + on(1), + off-act(2), + on-act(3)} + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This OID is provided for Outlet Status information. + + '0' if the out is Switch Off. + '1' if the out is Switch On. + '2' if the out is Switch Off Acting. + '3' if the out is Switch On Acting. + + " + ::= { outEntry 4 } + + outSwitchCtrl OBJECT-TYPE + SYNTAX INTEGER { + none(0), + ctrl-on(1), + ctrl-off(2), + ctrl-reboot(3), + ctrl-on-off(4)} + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This OID is provided for Outlet Status information. + + '0' if the out is None. + '1' Switch Ctrl On. + '2' Switch Ctrl Off. + '3' Switch Ctrl Reboot. + '4' Switch Ctrl On Off. + + " + ::= { outEntry 5 } + + outVoltage OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Voltage of Outlet." + ::= { outEntry 6 } + + outCurrent OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current of Outlet(In tenths of amps, divide by 10 for value in amps)." + ::= { outEntry 7 } + + outPowerFactor OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power factor in the Outlet." + ::= { outEntry 8 } + + outPowerLoad OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power in the Outlet." + ::= { outEntry 9 } + + outOverload OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Overload of Outlet(In tenths of amps, divide by 10 for value in amps)." + ::= { outEntry 10 } + + outHighWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High Warning of Outlet(In tenths of amps, divide by 10 for value in amps)." + ::= { outEntry 11 } + + outLowWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low Warning of Outlet(In tenths of amps, divide by 10 for value in amps)." + ::= { outEntry 12 } + +-- +-- PDU Table +-- + + pduTables OBJECT-TYPE + SYNTAX SEQUENCE OF PDUEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of PDU." + ::= { peripheralTables 4 } + + pduEntry OBJECT-TYPE + SYNTAX PDUEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Row definition for PDU table." + INDEX { pduIndex } + ::= { pduTables 1 } + + PDUEntry ::= SEQUENCE { + pduIndex INTEGER, + pduModel DisplayString, + pduMonitor INTEGER, + pduStatus INTEGER, + pduVoltage INTEGER, + pduFrequency INTEGER, + pduCurrent INTEGER, + pduPowerLoad INTEGER, + pduPowerFactor INTEGER, + pduPowerEnergy INTEGER, + pduOverload INTEGER, + pduHighWarning INTEGER, + pduLowWarning INTEGER, + pduBranch INTEGER, + pduBranch1Current INTEGER, + pduBranch1Overload INTEGER, + pduBranch1HighWarning INTEGER, + pduBranch1LowWarning INTEGER, + pduBranch2Current INTEGER, + pduBranch2Overload INTEGER, + pduBranch2HighWarning INTEGER, + pduBranch2LowWarning INTEGER + } + + pduIndex OBJECT-TYPE + SYNTAX INTEGER(1..8) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "PDU table index." + ::= { pduEntry 1 } + + pduModel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Now Power Data Log of PDU(In tenths of amps, divide by 10 for value in amps)." + ::= { pduEntry 2 } + + pduMonitor OBJECT-TYPE + SYNTAX INTEGER { + no(0), + yes(1)} + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "PDU Monitor Status." + ::= { pduEntry 3 } + + pduStatus OBJECT-TYPE + SYNTAX INTEGER { + no(0), + yes(1), + warning(2)} + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "PDU Connect Status." + ::= { pduEntry 4 } + + pduVoltage OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Voltage of PDU." + ::= { pduEntry 5 } + + pduFrequency OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frequency of PDU." + ::= { pduEntry 6 } + + pduCurrent OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total Current of PDU(In tenths of amps, divide by 10 for value in amps)." + ::= { pduEntry 7 } + + pduPowerLoad OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power in the PDU." + ::= { pduEntry 8 } + + pduPowerFactor OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power factor in the PDU." + ::= { pduEntry 9 } + + pduPowerEnergy OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power in the PDU." + ::= { pduEntry 10 } + + pduOverload OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Overload of PDU(In tenths of amps, divide by 10 for value in amps)." + ::= { pduEntry 11 } + + pduHighWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High Warning of PDU(In tenths of amps, divide by 10 for value in amps)." + ::= { pduEntry 12 } + + pduLowWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High Warning of PDU(In tenths of amps, divide by 10 for value in amps)." + ::= { pduEntry 13 } + + pduBranch OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { pduEntry 14 } + + pduBranch1Current OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { pduEntry 15 } + + pduBranch1Overload OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Overload of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { pduEntry 16 } + + pduBranch1HighWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { pduEntry 17 } + + pduBranch1LowWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { pduEntry 18 } + + pduBranch2Current OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { pduEntry 19 } + + pduBranch2Overload OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Overload of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { pduEntry 20 } + + pduBranch2HighWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { pduEntry 21 } + + pduBranch2LowWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps)." + ::= { pduEntry 22 } + +-- +-- InbuiltTemperature Table +-- + + inbuiltTemperatureTable OBJECT-TYPE + SYNTAX SEQUENCE OF InbuiltTemperatureEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of Inbuilt Temperature Sensor." + ::= { peripheralTables 5 } + + inbuiltTemperatureEntry OBJECT-TYPE + SYNTAX InbuiltTemperatureEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Row definition for Inbuilt Temperature Sensor table." + INDEX { inbuiltTemperatureIndex } + ::= { inbuiltTemperatureTable 1 } + + InbuiltTemperatureEntry ::= SEQUENCE { + inbuiltTemperatureIndex INTEGER, + inbuiltTemperatureStatus INTEGER, + inbuiltTemperature INTEGER, + inbuiltTemperatureHighWarning INTEGER, + inbuiltTemperatureLowWarning INTEGER + } + + inbuiltTemperatureIndex OBJECT-TYPE + SYNTAX INTEGER (0..8) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for the Inbuilt Temperature Sensor table." + ::= { inbuiltTemperatureEntry 1 } + + inbuiltTemperatureStatus OBJECT-TYPE + SYNTAX INTEGER { + no(0), + yes(1)} + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Inbuilt Temperature Sensor Connect Status." + ::= { inbuiltTemperatureEntry 2 } + + inbuiltTemperature OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Detected Temperature from Inbuilt Temperature Sensor." + ::= { inbuiltTemperatureEntry 3 } + + inbuiltTemperatureHighWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High Warning Temperature from Inbuilt Temperature Sensor." + ::= { inbuiltTemperatureEntry 4 } + + inbuiltTemperatureLowWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low Warning Temperature from Inbuilt Temperature Sensor." + ::= { inbuiltTemperatureEntry 5 } + +-- +-- ExtendTemperature Table +-- + + extendTemperatureTable OBJECT-TYPE + SYNTAX SEQUENCE OF ExtendTemperatureEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of Extend Temperature Sensor." + ::= { peripheralTables 6 } + + extendTemperatureEntry OBJECT-TYPE + SYNTAX ExtendTemperatureEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Row definition for Extend Temperature Sensor table." + INDEX { extendTemperatureIndex } + ::= { extendTemperatureTable 1 } + + ExtendTemperatureEntry ::= SEQUENCE { + extendTemperatureIndex INTEGER, + extendTemperatureDeviceId INTEGER, + extendTemperaturePort INTEGER, + extendTemperatureMonitor INTEGER, + extendTemperatureStatus INTEGER, + extendTemperature INTEGER, + extendTemperatureHighWarning INTEGER, + extendTemperatureLowWarning INTEGER + } + + extendTemperatureIndex OBJECT-TYPE + SYNTAX INTEGER (0..8) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for the Extend Temperature Sensor table." + ::= { extendTemperatureEntry 1 } + + extendTemperatureDeviceId OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Extend Temperature Monitor Status." + ::= { extendTemperatureEntry 2 } + + extendTemperaturePort OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Extend Temperature Monitor Status." + ::= { extendTemperatureEntry 3 } + + extendTemperatureMonitor OBJECT-TYPE + SYNTAX INTEGER { + no(0), + yes(1)} + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Extend Temperature Monitor Status." + ::= { extendTemperatureEntry 4 } + + extendTemperatureStatus OBJECT-TYPE + SYNTAX INTEGER { + no(0), + yes(1)} + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Extend Temperature Sensor Connect Status." + ::= { extendTemperatureEntry 5 } + + extendTemperature OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Detected Temperature from Inbuilt Temperature Sensor." + ::= { extendTemperatureEntry 6 } + + extendTemperatureHighWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High Warning Temperature from Extend Temperature Sensor." + ::= { extendTemperatureEntry 7 } + + extendTemperatureLowWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low Warning Temperature from Extend Temperature Sensor." + ::= { extendTemperatureEntry 8 } + +-- +-- extendRH Table +-- + + extendRHTable OBJECT-TYPE + SYNTAX SEQUENCE OF ExtendRHEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of Extend RH Sensor." + ::= { peripheralTables 7 } + + extendRHEntry OBJECT-TYPE + SYNTAX ExtendRHEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Row definition for Extend RH table." + INDEX { extendRHIndex } + ::= { extendRHTable 1 } + + ExtendRHEntry ::= SEQUENCE { + extendRHIndex INTEGER, + extendRHDeviceId INTEGER, + extendRHPort INTEGER, + extendRHMonitor INTEGER, + extendRHStatus INTEGER, + extendRH INTEGER, + extendRHHighWarning INTEGER, + extendRHLowWarning INTEGER + } + + extendRHIndex OBJECT-TYPE + SYNTAX INTEGER (0..8) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for the Extend RH Sensor table." + ::= { extendRHEntry 1 } + + extendRHDeviceId OBJECT-TYPE + SYNTAX INTEGER (0..8) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for the Extend RH Sensor table." + ::= { extendRHEntry 2 } + + extendRHPort OBJECT-TYPE + SYNTAX INTEGER (0..8) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for the Extend RH Sensor table." + ::= { extendRHEntry 3 } + + extendRHMonitor OBJECT-TYPE + SYNTAX INTEGER { + no(0), + yes(1)} + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Extend RH Monitor Status." + ::= { extendRHEntry 4 } + + extendRHStatus OBJECT-TYPE + SYNTAX INTEGER { + no(0), + yes(1)} + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Extend RH Sensor Connect Status." + ::= { extendRHEntry 5 } + + extendRH OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Detected RH from Inbuilt Temperature Sensor." + ::= { extendRHEntry 6 } + + extendRHHighWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High Warning RH from Extend Temperature Sensor." + ::= { extendRHEntry 7 } + + extendRHLowWarning OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low Warning RH from Extend Temperature Sensor." + ::= { extendRHEntry 8 } + +-- +-- Input Table +-- + + inputTable OBJECT-TYPE + SYNTAX SEQUENCE OF InputEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of Input." + ::= { peripheralTables 8 } + + inputEntry OBJECT-TYPE + SYNTAX InputEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Row definition for Input table." + INDEX { inputIndex } + ::= { inputTable 1 } + + InputEntry ::= SEQUENCE { + inputIndex INTEGER, + inputStatus INTEGER, + inputState INTEGER, + inputTimeout INTEGER, + inputDefault INTEGER, + inputDetectTime DisplayString +} + + inputIndex OBJECT-TYPE + SYNTAX INTEGER (1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for Input table." + ::= { inputEntry 1 } + + inputStatus OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This OID is provided for Input Status. + '0' NORMAL. + '1' WARNING. + '2' TIMEOUT. + " + ::= { inputEntry 2 } + + inputState OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This OID is provided for Input Default. + '0' NORMAL_CLOSE. + '1' NORMAL_OPEN. + " + ::= { inputEntry 3 } + + inputTimeout OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "TimeOut of Input Status." + ::= { inputEntry 4 } + + inputDefault OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This OID is provided for Input Default. + '0' NORMAL_CLOSE. + '1' NORMAL_OPEN. + " + ::= { inputEntry 5 } + + inputDetectTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Detect the nearest Changed Time of Input Status." + ::= { inputEntry 6 } + +-- +-- RFID reader +-- + + rfidReader OBJECT IDENTIFIER ::= { peripheralTables 9 } + + rfidCardNum OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "RFID Card Number." + ::= { rfidReader 1 } + + rfidDetectTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Nearest Time to detect RFID Card." + ::= { rfidReader 2 } + +-- +-- UPS +-- + + uPS OBJECT IDENTIFIER ::= { peripheralTables 10 } + + uPSModel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Model." + ::= { uPS 1 } + + uPSConnectStatus OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Connect Status." + ::= { uPS 2 } + + uPSFirmware OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Firmware." + ::= { uPS 3 } + + uPSSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Serial." + ::= { uPS 4 } + + uPSTemperature OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Temperature." + ::= { uPS 5 } + + uPSInputVoltage OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Input Voltage." + ::= { uPS 6 } + + uPSOutputOnBattery OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Output On Battery." + ::= { uPS 7 } + + uPSOutputVoltage OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Output Voltage." + ::= { uPS 8 } + + uPSOutputFrequency OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Output Voltage." + ::= { uPS 9 } + + uPSOutputCurrent OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Output Current." + ::= { uPS 10 } + + uPSOutputLoad OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Output Load." + ::= { uPS 11 } + + uPSOutputOverload OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Output Overload." + ::= { uPS 12 } + + uPSBatteryDate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Battery Date." + ::= { uPS 13 } + + uPSBatteryVoltage OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Battery Voltage." + ::= { uPS 14 } + + uPSBatteryLevel OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Battery Level." + ::= { uPS 15 } + + uPSBatteryRunTime OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Battery RunTime." + ::= { uPS 16 } + + uPSBatteryLow OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Battery Low." + ::= { uPS 17 } + + uPSBatteryReplace OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS Battery Need Replace." + ::= { uPS 18 } + + uPSUARTId OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "UPS UART Id." + ::= { uPS 19 } + +-- +-- MIC Detect +-- + + micDetec OBJECT IDENTIFIER ::= { peripheralTables 11 } + + micDetectTimes OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "MIC Detect Times." + ::= { micDetec 1 } + + micDetectPeriod OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "MIC Detect Period." + ::= { micDetec 2 } + + micLastDetectTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "MIC Detect Detect Time." + ::= { micDetec 3 } + +-- +-- Vibration Detect +-- + + vibrationDetec OBJECT IDENTIFIER ::= { peripheralTables 12 } + + vibrationDetectTimes OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Vibration Detect Times." + ::= { vibrationDetec 1 } + + vibrationDetectPeriod OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Vibration Detect Period." + ::= { vibrationDetec 2 } + + vibrationLastDetectTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Vibration Detect Detect Time." + ::= { vibrationDetec 3 } + + dataLogTable OBJECT IDENTIFIER ::= { smart 4 } + +-- +-- Input Feed Data Table +-- + + inFeedDataList OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Input Feed Data List." + ::= { dataLogTable 1 } + +-- +-- Outlet Table +-- + + outDataList OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Outlet Data List." + ::= { dataLogTable 2 } + +-- +-- PDU Table +-- + + pduDataList OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "PDU Data List." + ::= { dataLogTable 3 } + +-- +-- Enterprise Traps +-- + smartTraps OBJECT IDENTIFIER ::= { smart 100 } + + trap OBJECT IDENTIFIER ::= { smartTraps 1 } + -- the 0 is for V1 compatibility + + arg OBJECT IDENTIFIER ::= { smartTraps 2 } + + trapArg1 OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicate the Trap Arg1." + ::= { arg 1 } + + trapArg2 OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicate the Trap Arg2." + ::= { arg 2 } + + trapArg3 OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicate the Trap Arg3." + ::= { arg 3 } + + trapArg4 OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicate the Trap Arg4." + ::= { arg 4 } + + trapArg5 OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicate the Trap Arg5." + ::= { arg 5 } + + trapArg6 OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicate the Trap Arg6." + ::= { arg 6 } + + trapArg7 OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicate the Trap Arg7." + ::= { arg 7 } + + trapArg8 OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicate the Trap Arg8." + ::= { arg 8 } + + trapArg9 OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicate the Trap Arg9." + ::= { arg 9 } + + testTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1 + } + STATUS current + DESCRIPTION + "testData" + ::= { trap 1 } + + -- Input Feed Traps + + inFeedOverloadTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + deviceIndex, + inFeedIndex, + inFeedStatus, + inFeedCurrent, + inFeedOverload + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 101 } + + inFeedHighCurrentTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + deviceIndex, + inFeedIndex, + inFeedStatus, + inFeedCurrent, + inFeedHighWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 102 } + + inFeedLowCurrentTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + deviceIndex, + inFeedIndex, + inFeedStatus, + inFeedCurrent, + inFeedHighWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 103 } + + inFeedBranchOverloadTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + inFeedIndex, + BranchIndex, + inFeedStatus, + inFeedCurrent, + inFeedOverload + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 104 } + + inFeedBranchHighCurrentTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + inFeedIndex, + BranchIndex, + inFeedStatus, + inFeedCurrent, + inFeedHighWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 105 } + + inFeedBranchLowCurrentTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + inFeedIndex, + BranchIndex, + inFeedStatus, + inFeedCurrent, + inFeedHighWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 106 } + + outWebOperationTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3 + } + STATUS current + DESCRIPTION + "Outlet on/off change event. If enabled, this trap is sent + when the outStatus changes from any 'on' state ('on', + 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', + 'offWait', 'offError', or 'offFuse'), and vice-versa." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 201 } + + outPanelOperationTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3 + } + STATUS current + DESCRIPTION + "Outlet on/off change event. If enabled, this trap is sent + when the outStatus changes from any 'on' state ('on', + 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', + 'offWait', 'offError', or 'offFuse'), and vice-versa." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 202 } + + outAPIOperationTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3 + } + STATUS current + DESCRIPTION + "Outlet on/off change event. If enabled, this trap is sent + when the outStatus changes from any 'on' state ('on', + 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', + 'offWait', 'offError', or 'offFuse'), and vice-versa." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 203 } + + outScheduleTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5, + trapArg6, + trapArg7, + trapArg8, + trapArg9 + } + STATUS current + DESCRIPTION + "Outlet on/off change event. If enabled, this trap is sent + when the outStatus changes from any 'on' state ('on', + 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', + 'offWait', 'offError', or 'offFuse'), and vice-versa." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 211 } + + outScheduleErrorTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5, + trapArg6, + trapArg7 + } + STATUS current + DESCRIPTION + "Outlet on/off change event. If enabled, this trap is sent + when the outStatus changes from any 'on' state ('on', + 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', + 'offWait', 'offError', or 'offFuse'), and vice-versa." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 212 } + + outPingTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4 + } + STATUS current + DESCRIPTION + "Outlet on/off change event. If enabled, this trap is sent + when the outStatus changes from any 'on' state ('on', + 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', + 'offWait', 'offError', or 'offFuse'), and vice-versa." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 221 } + + outPingRebootTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4 + } + STATUS current + DESCRIPTION + "Outlet on/off change event. If enabled, this trap is sent + when the outStatus changes from any 'on' state ('on', + 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', + 'offWait', 'offError', or 'offFuse'), and vice-versa." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 222 } + + outOverloadTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + deviceIndex, + outIndex, + outCurrentStatus, + outCurrent, + outHighWarning + Outlet load event. If enabled, this trap is sent when the + outLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the outLoadStatus + remains in an error state. If the outLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error outLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 231 } + + outHighCurrentTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + deviceIndex, + outIndex, + outCurrentStatus, + outCurrent, + outHighWarning + Outlet load event. If enabled, this trap is sent when the + outLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the outLoadStatus + remains in an error state. If the outLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error outLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 232 } + + outLowCurrentTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + deviceIndex, + outIndex, + outCurrentStatus, + outCurrent, + outLowWarning + Outlet load event. If enabled, this trap is sent when the + outLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the outLoadStatus + remains in an error state. If the outLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error outLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 233 } + + outConditionCtrlTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + deviceIndex, + outIndex, + outCurrentStatus, + outCurrent, + outLowWarning + Outlet load event. If enabled, this trap is sent when the + outLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the outLoadStatus + remains in an error state. If the outLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error outLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 241 } + + outUPSACFaultOffTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2 + } + STATUS current + DESCRIPTION + " + deviceIndex, + value + Outlet load event. If enabled, this trap is sent when the + outLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the outLoadStatus + remains in an error state. If the outLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error outLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 311 } + + outUPSBatteryLevelOffTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2 + } + STATUS current + DESCRIPTION + " + deviceIndex, + value + Outlet load event. If enabled, this trap is sent when the + outLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the outLoadStatus + remains in an error state. If the outLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error outLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 312 } + + outUPSBatteryLowOffTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2 + } + STATUS current + DESCRIPTION + " + deviceIndex, + value + Outlet load event. If enabled, this trap is sent when the + outLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the outLoadStatus + remains in an error state. If the outLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error outLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 313 } + + outUPSACRecoveryOnTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2 + } + STATUS current + DESCRIPTION + " + deviceIndex, + value + Outlet load event. If enabled, this trap is sent when the + outLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the outLoadStatus + remains in an error state. If the outLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error outLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 314 } + + outUPSBatteryLevelOnTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2 + } + STATUS current + DESCRIPTION + " + deviceIndex, + value + Outlet load event. If enabled, this trap is sent when the + outLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the outLoadStatus + remains in an error state. If the outLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error outLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 315 } + + outUPSBatteryLowRecoveryOnTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2 + } + STATUS current + DESCRIPTION + " + deviceIndex, + value + Outlet load event. If enabled, this trap is sent when the + outLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the outLoadStatus + remains in an error state. If the outLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error outLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 316 } + + pduConnectTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2 + } + STATUS current + DESCRIPTION + " + PDUIndex, + PDUConnectStatus + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 401 } + + pduOverloadTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + deviceIndex, + PDUIndex, + PDUStatus, + PDUCurrent, + PDUOverload + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 402 } + + pduHighCurrentTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + deviceIndex, + PDUIndex, + PDUStatus, + PDUCurrent, + PDUHighWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 403 } + + pduLowCurrentTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + deviceIndex, + PDUIndex, + PDUStatus, + PDUCurrent, + PDUHighWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 404 } + + pduBranchOverloadTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + PDUIndex, + BranchIndex, + PDUStatus, + PDUCurrent, + PDUOverload + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 405 } + + pduBranchHighCurrentTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + PDUIndex, + BranchIndex, + PDUStatus, + PDUCurrent, + PDUHighWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 406 } + + pduBranchLowCurrentTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + PDUIndex, + BranchIndex, + PDUStatus, + PDUCurrent, + PDUHighWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 407 } + + inbuiltTemperatureHighTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4 + } + STATUS current + DESCRIPTION + " + InTempId, + InTempStatus, + InTempTemperature, + InTempTemperatureWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 501 } + + inbuiltTemperatureLowTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4 + } + STATUS current + DESCRIPTION + " + InTempId, + InTempStatus, + InTempTemperature, + InTempTemperatureWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 502 } + + envConnectTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3 + } + STATUS current + DESCRIPTION + " + deviceIndex, + ENVIndex, + ENVConnectStatus + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 511 } + + envTemperatureConnectTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3 + } + STATUS current + DESCRIPTION + " + deviceIndex, + ENVIndex, + ENVConnectStatus + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 512 } + + envTemperatureHighTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5, + trapArg6 + } + STATUS current + DESCRIPTION + " + deviceIndex, + EnvId, + EnvStatus, + EnvTemperature, + EnvTemperatureWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 513 } + + envTemperatureLowTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5, + trapArg6 + } + STATUS current + DESCRIPTION + " + deviceIndex, + EnvId, + EnvStatus, + EnvTemperature, + EnvTemperatureWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 514 } + + envRHConnectTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + deviceIndex, + EnvId, + EnvStatus, + EnvRH, + EnvRHWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 515 } + + envRHHighTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + deviceIndex, + EnvId, + EnvStatus, + EnvRH, + EnvRHWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 516 } + + envRHLowTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4, + trapArg5 + } + STATUS current + DESCRIPTION + " + deviceIndex, + EnvId, + EnvStatus, + EnvRH, + EnvRHWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 517 } + + inputTimeOutTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4 + } + STATUS current + DESCRIPTION + " + deviceIndex, + EnvId, + EnvStatus, + EnvTemperature, + EnvTemperatureWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 601 } + + inputTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2, + trapArg3, + trapArg4 + } + STATUS current + DESCRIPTION + " + deviceIndex, + EnvId, + EnvStatus, + EnvTemperature, + EnvTemperatureWarning + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 602 } + + upsConnectTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2 + } + STATUS current + DESCRIPTION + " + Model, + ConnectStatus + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 701 } + + upsOnBatteryTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2 + } + STATUS current + DESCRIPTION + " + Model, + ConnectStatus + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 702 } + + upsOverloadTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2 + } + STATUS current + DESCRIPTION + " + Model, + ConnectStatus + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 703 } + + upsBatteryLowTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2 + } + STATUS current + DESCRIPTION + " + Model, + ConnectStatus + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 704 } + + upsBatteryReplace NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2 + } + STATUS current + DESCRIPTION + " + Model, + ConnectStatus + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 705 } + + daisyChainConnectTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2 + } + STATUS current + DESCRIPTION + " + Model, + ConnectStatus + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 801 } + + micDetectOccurTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2 + } + STATUS current + DESCRIPTION + " + Model, + ConnectStatus + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 901 } + + vibrationDetectOccurTrap NOTIFICATION-TYPE + OBJECTS { + trapArg1, + trapArg2 + } + STATUS current + DESCRIPTION + " + Model, + ConnectStatus + Input feed load event. If enabled, this trap is sent when + the infeedLoadStatus indicates an error state ('loadLow', + 'loadHigh', 'overLoad', 'readError', or 'noComm'). This + trap is repeated periodically while the infeedLoadStatus + remains in an error state. If the infeedLoadStatus returns + to a non-error state ('normal' or 'notOn'), this trap is + sent once more with the non-error infeedLoadStatus, and then + stops being repeated." + --#SUMMARY "The appliance is rebooting. Command issued by user: %s." + --#ARGUMENTS { 0 } + --#SEVERITY INFORMATIONAL + --#CATEGORY "Status Events" + --NAME "Appliance Rebooting" + --SHORT "appliance rebooting" + --EVENT evt_reboot + --% TrapTypeEnum=15 + ::= { trap 902 } + +END -- cgit v1.2.3