summaryrefslogtreecommitdiff
path: root/MIBS/junose/Juniper-System-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/junose/Juniper-System-MIB
downloadmibs-main.tar.gz
mibs-main.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/junose/Juniper-System-MIB')
-rw-r--r--MIBS/junose/Juniper-System-MIB3622
1 files changed, 3622 insertions, 0 deletions
diff --git a/MIBS/junose/Juniper-System-MIB b/MIBS/junose/Juniper-System-MIB
new file mode 100644
index 0000000..e277843
--- /dev/null
+++ b/MIBS/junose/Juniper-System-MIB
@@ -0,0 +1,3622 @@
+
+-- *****************************************************************************
+-- Juniper-System-MIB
+--
+-- Juniper Networks Enterprise MIB
+-- E-series System MIB
+--
+-- Copyright (c) 2002-2008 Juniper Networks, Inc. All Rights Reserved.
+-- *****************************************************************************
+
+Juniper-System-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Unsigned32,
+ Gauge32, TimeTicks
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION, DisplayString, TruthValue, DateAndTime
+ FROM SNMPv2-TC
+ MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
+ FROM SNMPv2-CONF
+ PhysicalIndex, entPhysicalDescr
+ FROM ENTITY-MIB
+ KBytes
+ FROM HOST-RESOURCES-MIB
+ InterfaceIndexOrZero
+ FROM IF-MIB
+ juniMibs
+ FROM Juniper-MIBs
+ JuniEnable, JuniTimeFilter
+ FROM Juniper-TC;
+
+juniSystemMIB MODULE-IDENTITY
+ LAST-UPDATED "200806111101Z" -- 11-Jun-08 07:01 AM EDT
+ ORGANIZATION "Juniper Networks, Inc."
+ CONTACT-INFO
+ " Juniper Networks, Inc.
+ Postal: 10 Technology Park Drive
+ Westford, MA 01886-3146
+ USA
+ Tel: +1 978 589 5800
+ Email: mib@Juniper.net"
+ DESCRIPTION
+ "The MIB objects for managing a Juniper E-series (JUNOSe) system. This
+ MIB complements the ENTITY-MIB.entPhysicalTable by providing the
+ system's physical information in a format that is more user friendly and
+ provides additional elements not found in the Entity MIB, including
+ state information, parameters for configuring the system and additional
+ notifications.
+
+ There are two families of E-series hardware systems supported by this
+ MIB:
+ ERX - first generation E-series systems
+ ES2 - second generation E-series systems "
+ -- Revision History
+ REVISION "200806111101Z" -- 11-Jun-08 07:01 AM EDT - JUNOSe 10.0
+ DESCRIPTION
+ "Added es2Lm10s support."
+ REVISION "200805051241Z" -- 05-May-08 08:41 AM EDT - JUNOSe 9.2
+ DESCRIPTION
+ "Add ISSU Support for ERX-1440."
+ REVISION "200705071012Z" -- 07-May-07 06:12 AM EDT - JUNOSe 9.0
+ DESCRIPTION
+ "Add ISSU support."
+ REVISION "200612182125Z" -- 18-Dec-06 04:25 PM EST - JUNOSe 8.3
+ DESCRIPTION
+ "Add LM10 Access Support."
+ REVISION "200611240913Z" -- 24-Nov-06 04:13 AM EST - JUNOSe 8.2
+ DESCRIPTION
+ "Add suppot for ES2 primary modules SRP-120 and SFM-120 for E120."
+ REVISION "200605180831Z" -- 18-May-06 02:01 PM EST - JUNOSe 8.0
+ DESCRIPTION
+ "Add last 5 seconds, 1 minute and 5 minutes avergae CPU utilzation
+ support."
+ REVISION "200601061817Z" -- 06-Jan-06 01:17 PM EST - JUNOSe main
+ DESCRIPTION
+ "Add LM10 Access Support."
+ REVISION "200512160721Z" -- 16-Dec-05 12:51 PM EST - JUNOSe main
+ DESCRIPTION
+ "Changed maximum value of juniSystemHighMemUtilThreshold from 100 to 99
+ and maximum value of juniSystemAbatedMemUtilThreshold from 99 to 98."
+ REVISION "200511182230Z" -- 18-Nov-05 05:30 PM EST - JUNOSe 7.3
+ DESCRIPTION
+ "Add CPU utilization statitics table support."
+ REVISION "200509151414Z" -- 15-Sep-05 10:14 AM EDT - JUNOSe 7.2
+ DESCRIPTION
+ "Add LM10 Uplink Support."
+ REVISION "200508191748Z" -- 29-Jul-05 01:48 PM EDT - JUNOSe main
+ DESCRIPTION
+ "Add Ge8 support."
+ REVISION "200507291748Z" -- 29-Jul-05 01:48 PM EDT - JUNOSe 7.0.1
+ DESCRIPTION
+ "conform to REX Naming Document, renamed various ES2 module types
+ and deleted ones that didn't belong."
+ REVISION "200505181810Z" -- 18-May-05 02:10 PM EDT - JUNOSe 7.0.0
+ DESCRIPTION
+ "Updated JuniSystemModuleType TC and created JuniSystemSlotLevel TC."
+ REVISION "200505041810Z" -- 04-May-05 02:10 PM EDT - JUNOSe 7.0.0
+ DESCRIPTION
+ "Added GE-HDE support."
+ REVISION "200501311813Z" -- 31-Jan-05 02:13 PM EDT - JUNOSe 5.1.5
+ DESCRIPTION
+ "Added KByte memory capacity object to notification."
+ REVISION "200412311013Z" -- 31-Dec-04 05:13 AM EST - JUNOSe main
+ DESCRIPTION
+ "Updated for second generation E-series router."
+
+ REVISION "200412291010Z" -- 29-Dec-04 05:10 AM EST - JUNOSe 6.1
+ DESCRIPTION
+ "Updated SystemTimingSelector TC and related timing objects."
+ REVISION "200405251813Z" -- 25-May-04 02:13 PM EDT - JUNOSe 6.1
+ DESCRIPTION
+ "Added support for the Fe8 FX IOA."
+ REVISION "200401072246Z" -- 07-Jan-04 05:46 PM EST - JUNOSe 6.0
+ DESCRIPTION
+ "Added support for the second generation E-series hardware
+ architecture."
+ REVISION "200311242059Z" -- 24-Nov-03 03:59 PM EST - JUNOSe 5.3
+ DESCRIPTION
+ "Added Hybrid Primary Module and Hybrid IOA modules.
+ Added GE2 Primary Module and GE2 IOA module."
+ REVISION "200311241939Z" -- 24-Nov-03 02:39 PM EST - JUNOSe 5.2
+ DESCRIPTION
+ "Added resource utilization notification enable/disable.
+ Added KByte memory capacilty object."
+ REVISION "200307221410Z" -- 22-Jul-03 10:10 AM EDT - JUNOSe 5.1
+ DESCRIPTION
+ "Added ERX-310 support."
+ REVISION "200301272122Z" -- 27-Jan-03 04:22 PM EST - JUNOSe 5.0
+ DESCRIPTION
+ "Replaced Unisphere names with Juniper names.
+ Added resource utilization notification support."
+ REVISION "200210172101Z" -- 17-Oct-02 05:01 PM EDT - JUNOSe 4.1
+ DESCRIPTION
+ "Initial version of this MIB module."
+ ::= { juniMibs 2 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Textual conventions
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+JuniSystemModuleType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The 'personality' type of a module found in an E-series system. Some
+ primary modules (e.g., line cards) have only one personality; that is
+ they only accept one personality of other level modules (e.g. I/O
+ adapters) in the same slot and are always configured in the same way.
+ Other modules are multi-personality and will behave differently
+ depending on the other level modules they are operating with, and
+ therefore cannot be configured without knowing the other level module
+ type(s). Type values in this table include both. Types that are
+ multi-personality are noted by [MP] and types that are personality-only
+ are noted by [PO]. Use the ENTITY-MIB to deretmine the actual hardware
+ type of a module with personality-only type.
+
+ unknown Unknown module type
+ ERX primary modules:
+ erxSrp ERX Switch/Route Processor
+ erxCt3 ERX 3 port Channelized T3
+ erxOc3 ERX 2 port OC3 SONET/SDH
+ erxUt3Atm ERX 3 port Unchannelized T3 ATM
+ erxUt3Frame ERX 3 port Unchannelized T3 Frame
+ erxUe3Atm ERX 3 port Unchannelized E3 ATM
+ erxUe3Frame ERX 3 port Uncahnnelized E3 Frame
+ erxCe1 ERX 20 port Channelized E1
+ erxCt1 ERX 24 port Channelized T1
+ erxDpfe ERX 2 port Fast Ethernet
+ erxOc12Pos ERX 1 port OC12 POS
+ erxOc12Atm ERX 1 port OC12 ATM
+ erxOc3Pos ERX 4 port OC3 POS
+ erxOc3Atm ERX 4 port OC3 ATM
+ erxGe ERX 1 port Gigabit Ethernet [PO]
+ erxFe8 ERX 8 port Fast Ethernet [PO]
+ erxOc3oc12Pos ERX OC3/OC12 POS [MP]
+ erxOc3oc12Atm ERX OC3/OC12 ATM [MP]
+ erxCoc3oc12 ERX Channelized OC3/OC12 [MP]
+ erxCoc3 ERX 4 port Channelized OC3 [PO]
+ erxCoc12 ERX 1 port Channelized OC12 [PO]
+ erxOc12Server ERX 1 port OC12 Tunnel Server
+ erxHssi ERX 3 port High Speed Serial Interface
+ erxGeFe ERX Gigabit Ethernet / Fast Ethernet [MP]
+ erxCt3P12 ERX 12 port Channelized T3
+ erxV35 ERX 16 port X.21/V.35
+ erxUt3f12 ERX 12 port Unchannelized T3 Frame [PO]
+ erxUe3f12 ERX 12 port Unchannelized E3 Frame [PO]
+ erxCoc12F3 ERX 1 port OC12 channelized to T3/E3 [PO]
+ erxCoc3F3 ERX 4 port OC3 channelized to T3/E3 [PO]
+ erxCocxF3 ERX OC3/OC12 channelized to T3/E3 [MP]
+ erxVts ERX Virtual Tunnel Server
+ erxOc48 ERX 1 port OC48 SONET/SDH
+ erxUt3Atm4 ERX 4 port Unchannelized T3/E3 ATM [PO]
+ erxHybrid ERX ATM / POS / Gigabit Ethernet Hybrid [MP]
+ erxOc3AtmGe ERX 2 port OC3 ATM 1 port Gigabit Ethernet [PO]
+ erxOc3AtmPos ERX 2 port OC3 ATM 2 port OC3 POS [PO]
+ erxGe2 ERX 2 port Gigabit Ethernet
+ erxGeHde ERX 2/8 port Gigabit Ethernet
+ ERX I/O adapter (IOA) modules:
+ erxSrpIoa ERX Switch/Route Processor IOA
+ erxCt1Ioa ERX 24 port channelized T1/J1 IOA
+ erxCe1Ioa ERX 20 port channelized E1 IOA
+ erxCe1TIoa ERX 20 port channelized E1 Telco IOA
+ erxCt3Ioa ERX 3 port channelized T3/E3 IOA
+ erxE3Ioa ERX 3 port E3 IOA
+ erxOc3Mm2Ioa ERX 2 port OC3 multi-mode IOA
+ erxOc3Sm2Ioa ERX 2 port OC3 single-mode IOA
+ erxOc3Mm4Ioa ERX 4 port OC3 multi-mode IOA
+ erxOc3SmIr4Ioa ERX 4 port OC3 single-mode
+ intermediate-reach IOA
+ erxOc3SmLr4Ioa ERX 4 port OC3 single-mode long-reach IOA
+ erxCOc3Mm4Ioa ERX 4 port channelized OC3 multi-mode IOA
+ erxCOc3SmIr4Ioa ERX 4 port channelized OC3 single-mode
+ intermediate-reach IOA
+ erxCOc3SmLr4Ioa ERX 4 port channelized OC3 single-mode
+ long-reach IOA
+ erxOc12Mm1Ioa ERX 1 port OC12 multi-mode IOA
+ erxOc12SmIr1Ioa ERX 1 port OC12 single-mode
+ intermediate-reach IOA
+ erxOc12SmLr1Ioa ERX 1 port OC12 single-mode long-reach IOA
+ erxCOc12Mm1Ioa ERX 1 port channelized OC12 multi-mode IOA
+ erxCOc12SmIr1Ioa ERX 1 port channelized OC12 single-mode
+ intermediate-reach IOA
+ erxCOc12SmLr1Ioa ERX 1 port channelized OC12 single-mode
+ long-reach IOA
+ erxFe2Ioa ERX 2 port 10/100 Fast Ethernet IOA
+ erxFe8Ioa ERX 8 port 10/100 Fast Ethernet IOA
+ erxGeMm1Ioa ERX 1 port Gigabit Ethernet multi-mode IOA
+ erxGeSm1Ioa ERX 1 port Gigabit Ethernet single-mode
+ IOA
+ erxHssiIoa ERX 3 port High Speed Serial Interface IOA
+ erxCt3P12Ioa ERX 12 port channelized and unchannelized
+ T3 IOA
+ erxV35Ioa ERX 16 port X2.1/V3.5 IOA
+ erxGeSfpIoa ERX 1 port Gigabit Ethernet SFP IOA
+ erxUe3P12Ioa ERX 12 port unchannelized E3 IOA
+ erxT3Atm4Ioa ERX 4 port T3 ATM IOA
+ erxCOc12Mm1ApsIoa ERX 1 port channelized OC12 multi-mode APS
+ (1+1) IOA
+ erxCOc12SmIr1ApsIoa ERX 1 port channelized OC12 single-mode
+ intermediate-reach APS (1+1) IOA
+ erxCOc12SmLr1ApsIoa ERX 1 port channelized OC12 single-mode
+ long-reach APS (1+1) IOA
+ erxOc12Mm1ApsIoa ERX 1 port OC12 multi-mode APS (1+1) IOA
+ erxOc12SmIr1ApsIoa ERX 1 port OC12 single-mode
+ intermediate-reach APS (1+1) IOA
+ erxOc12SmLr1ApsIoa ERX 1 port OC12 single-mode long-reach APS
+ (1+1) IOA
+ erxCOc12AtmPosMm1Ioa ERX 1 port channelized OC12 multi-mode
+ ATM/POS IOA
+ erxCOc12AtmPosSmIr1Ioa ERX 1 port channelized OC12 single-mode
+ intermediate-reach ATM/POS IOA
+ erxCOc12AtmPosSmLr1Ioa ERX 1 port channelized OC12 single-mode
+ long-reach ATM/POS IOA
+ erxCOc12AtmPosMm1ApsIoa ERX 1 port channelized OC12 multi-mode
+ ATM/POS APS (1+1) IOA
+ erxCOc12AtmPosSmIr1ApsIoa ERX 1 port channelized OC12 single-mode
+ intermediate-reach ATM/POS APS (1+1) IOA
+ erxCOc12AtmPosSmLr1ApsIoa ERX 1 port channelized OC12 single-mode
+ long-reach ATM/POS APS (1+1) IOA
+ erxT1E1RedundantIoa ERX T1/E1 redundant midplane spare IOA
+ erxT3E3RedundantIoa ERX T3/E3 redundant midplane spare IOA
+ erxCt3RedundantIoa ERX channelized T3 redundant midplane
+ spare IOA
+ erxOcxRedundantIoa ERX OC3/OC12 redundant midplane spare IOA
+ erxCOcxRedundantIoa ERX channelized OC3/OC12 redundant
+ midplane spare IOA
+ erxOc3Mm4ApsIoa ERX 4 port OC3 multi-mode APS (1+1) IOA
+ erxOc3SmIr4ApsIoa ERX 4 port OC3 single-mode
+ intermediate-reach APS (1+1) IOA
+ erxOc3SmLr4ApsIoa ERX 4 port OC3 single-mode long-reach APS
+ (1+1) IOA
+ erxOc48Ioa ERX 1 port OC48/STM16 IOA
+ erxOc3Atm2Ge1Ioa ERX 2 port OC3 ATM 1 port GE IOA
+ erxOc3Atm2Pos2Ioa ERX 2 port OC3 ATM 2 port OC3 POS IOA
+ erxGe2Ioa ERX 2 port Gigabit Ethernet IOA
+ erxFe8FxIoa ERX 8 port 100 Fast Ethernet SFP IOA
+ erxGe8Ioa ERX 8 port Gigabit Ethernet IOA
+ ES2 primary modules:
+ e320Srp100 ES2 100Gb System Route Processor with integrated
+ fabric slice
+ e320Sfm100 ES2 100Gb Switch Fabric Slice
+ es2Lm4 ES2 4Gb (series 1) Line Module(LM).
+ es2Lm10Uplink ES2 10Gb (series 2) Uplink Line Module(LM).
+ es2Lm10 ES2 10Gb (series 3) Line Module(LM).
+ e320Srp320 ES2 320Gb System Route Processor with integrated
+ fabric slice
+ e320Sfm320 ES2 320Gb Switch Fabric Slice
+ es2Lm10s ES2 10Gb (series 4) Line Module(LM).
+ ES2 I/O adapter (IOA) modules:
+ e320SrpIoa ES2 system resource processor IOA
+ es2Ge4S1Ioa ES2 4 port Gigabit Ethernet S1 IOA
+ es2Oc48Stm16PosS1Ioa ES2 OC48/STM16 POS S1 IOA
+ es2ServiceS1Ioa ES2 Service S1 IOA
+ es2Oc3Stm1x8AtmS1Ioa ES2 OC3/STM1-8 ATM S1 IOA
+ es2RedundancyS1Ioa ES2 Redundancy S1 IOA
+ es2Oc12Stm4x2PosS1Ioa ES2 OC12/STM4-2 POS S1 IOA
+ es2Oc12Stm4x2AtmS1Ioa ES2 OC12/STM4-2 ATM S1 IOA
+ es2dash10GeS1Ioa ES2 10GE-1 SR S1 IOA
+ es2Ge8S1Ioa ES2 8 port Gigabit Ethernet S1 IOA
+ es2dash10GePrS2Ioa ES2 10GE-1 Port Redundancy S2 IOA
+ es2Ge20S2Ioa ES2 20 port Gigabit Ethernet S2 IOA
+ ES2 primary modules for E120:
+ e120Srp120 ES2 120Gb System Route Processor with integrated
+ fabric slice
+ e120Sfm120 ES2 120Gb Switch Fabric Slice"
+
+
+ SYNTAX INTEGER {
+ unknown(0),
+ -- ERX primary module types
+ erxSrp(1),
+ erxCt3(2),
+ erxOc3(3),
+ erxUt3Atm(4),
+ erxUt3Frame(5),
+ erxUe3Atm(6),
+ erxUe3Frame(7),
+ erxCe1(8),
+ erxCt1(9),
+ erxDpfe(10),
+ erxOc12Pos(11),
+ erxOc12Atm(12),
+ erxOc3Pos(13),
+ erxOc3Atm(14),
+ erxGe(15),
+ erxFe8(16),
+ erxOc3oc12Pos(17),
+ erxOc3oc12Atm(18),
+ erxCoc3oc12(19),
+ erxCoc3(20),
+ erxCoc12(21),
+ erxOc12Server(22),
+ erxHssi(23),
+ erxGeFe(24),
+ erxCt3P12(25),
+ erxV35(26),
+ erxUt3f12(27),
+ erxUe3f12(28),
+ erxCoc12F3(29),
+ erxCoc3F3(30),
+ erxCocxF3(31),
+ erxVts(32),
+ erxOc48(33),
+ erxUt3Atm4(34),
+ erxHybrid(35),
+ erxOc3AtmGe(36),
+ erxOc3AtmPos(37),
+ erxGe2(38),
+ erxGeHde(39),
+ -- ERX I/O adapter (IOA) module types
+ erxSrpIoa(1024),
+ erxCt1Ioa(1025),
+ erxCe1Ioa(1026),
+ erxCe1TIoa(1027),
+ erxCt3Ioa(1028),
+ erxE3Ioa(1029),
+ erxOc3Mm2Ioa(1030),
+ erxOc3Sm2Ioa(1031),
+ erxOc3Mm4Ioa(1032),
+ erxOc3SmIr4Ioa(1033),
+ erxOc3SmLr4Ioa(1034),
+ erxCOc3Mm4Ioa(1035),
+ erxCOc3SmIr4Ioa(1036),
+ erxCOc3SmLr4Ioa(1037),
+ erxOc12Mm1Ioa(1038),
+ erxOc12SmIr1Ioa(1039),
+ erxOc12SmLr1Ioa(1040),
+ erxCOc12Mm1Ioa(1041),
+ erxCOc12SmIr1Ioa(1042),
+ erxCOc12SmLr1Ioa(1043),
+ erxFe2Ioa(1044),
+ erxFe8Ioa(1045),
+ erxGeMm1Ioa(1046),
+ erxGeSm1Ioa(1047),
+ erxHssiIoa(1048),
+ erxCt3P12Ioa(1049),
+ erxV35Ioa(1050),
+ erxGeSfpIoa(1051),
+ erxUe3P12Ioa(1052),
+ erxT3Atm4Ioa(1053),
+ erxCOc12Mm1ApsIoa(1054),
+ erxCOc12SmIr1ApsIoa(1055),
+ erxCOc12SmLr1ApsIoa(1056),
+ erxOc12Mm1ApsIoa(1057),
+ erxOc12SmIr1ApsIoa(1058),
+ erxOc12SmLr1ApsIoa(1059),
+ erxCOc12AtmPosMm1Ioa(1060),
+ erxCOc12AtmPosSmIr1Ioa(1061),
+ erxCOc12AtmPosSmLr1Ioa(1062),
+ erxCOc12AtmPosMm1ApsIoa(1063),
+ erxCOc12AtmPosSmIr1ApsIoa(1064),
+ erxCOc12AtmPosSmLr1ApsIoa(1065),
+ erxT1E1RedundantIoa(1066),
+ erxT3E3RedundantIoa(1067),
+ erxCt3RedundantIoa(1068),
+ erxOcxRedundantIoa(1069),
+ erxCOcxRedundantIoa(1070),
+ erxOc3Mm4ApsIoa(1071),
+ erxOc3SmIr4ApsIoa(1072),
+ erxOc3SmLr4ApsIoa(1073),
+ erxOc48Ioa(1074),
+ erxOc3Atm2Ge1Ioa(1075),
+ erxOc3Atm2Pos2Ioa(1076),
+ erxGe2Ioa(1077),
+ erxFe8FxIoa(1078),
+ erxGe8Ioa(1079),
+ -- ES2 primary module types
+ e320Srp100(2048),
+ e320Sfm100(2049),
+ es2Lm4(2050),
+ es2Lm10Uplink(2051),
+ es2Lm10(2052),
+ e320Srp320(2053),
+ e320Sfm320(2054),
+ es2Lm10s(2055),
+ -- ES2 I/O adapter (IOA) module types
+ e320SrpIoa(3072),
+ es2Ge4S1Ioa(3073),
+ es2Oc48Stm16PosS1Ioa(3074),
+ es2ServiceS1Ioa(3075),
+ es2Oc3Stm1x8AtmS1Ioa(3076),
+ es2RedundancyS1Ioa(3077),
+ es2Oc12Stm4x2PosS1Ioa(3078),
+ es2Oc12Stm4x2AtmS1Ioa(3079),
+ es2dash10GeS1Ioa(3080),
+ es2Ge8S1Ioa(3081),
+ es2dash10GePrS2Ioa(3082),
+ es2Ge20S2Ioa(3083) ,
+ -- ES2 primary module types for E120
+ e120Srp120(4096),
+ e120Sfm120(4097) }
+
+JuniSystemSlotLevel ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The relative position of a module or sub-module 'container' within a
+ slot. The upper limit of valid values is juniSystemMaxModulesPerSlot.
+ A module or sub-module in the lowest numbered level for a particular
+ slot is considered to be the 'primary' module for that slot.
+
+ For the first generation E-series (ERX) platform family:
+ level 1 - SRP or line card module
+ level 2 - I/O adapter module
+
+ For the second generation E-series platform family:
+ level 1 - Forwarding module or SRP sub-module
+ level 2 - Switch fabric slice (SFS) sub-module or module
+ level 3 - Bay 0 I/O adapter
+ level 4 - Bay 1 I/O adapter "
+
+ SYNTAX Integer32 (1..4)
+
+JuniSystemSlotType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The type of 'container' for holding a module or sub-module found in an
+ E-series chassis.
+
+ The slot type may be for a 'sub-module' where there are multiple logical
+ functions on a single hardware module. For example, the second
+ generation SRP hardware module (slot 6 or 7 on an E320) contains both a
+ System Resource Processor (SRP) sub-module (level 1 position) and a
+ Switch Fabric Slice (SFS) sub-module (level 2 position).
+
+ noSlot The slot does not exist
+ ERX system slot types:
+ erxSrpSlot ERX switch/route processor module slot
+ erxLcmSlot ERX line card module slot
+ erxSrpIoaSlot ERX switch/route processor I/O adapter slot
+ erxLcIoaSlot ERX line card I/O adapter slot
+ Second generation E-series (ES2) system slot types:
+ es2SrpSlot ES2 system resource processor sub-module slot
+ es2SfsSlot ES2 switch fabric module or sub-module slot
+ es2FmSlot ES2 forwarding module slot
+ es2SrpIoaSlot ES2 system resource processor I/O adapter slot
+ es2FIoaSlot ES2 forwarding I/O adapter slot "
+ SYNTAX INTEGER {
+ noSlot(0),
+ -- ERX system slot types
+ erxSrpSlot(1),
+ erxLcmSlot(2),
+ erxSrpIoaSlot(3),
+ erxLcIoaSlot(4),
+ -- ES2 system slot types
+ es2SrpSlot(16),
+ es2SfsSlot(17),
+ es2FmSlot(18),
+ es2SrpIoaSlot(19),
+ es2FIoaSlot(20) }
+
+JuniSystemTimingSelector ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The system timing selector.
+ primary - the primary timing selector
+ secondary - the secondary timing selector
+ tertiary - the tertiary timing selector
+ error - the error in timing selector"
+ SYNTAX INTEGER {
+ primary(1),
+ secondary(2),
+ tertiary(3),
+ error(4)}
+
+JuniSystemLocationType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The location information class that is used to understand the encoding
+ of the associated location instance information. An object with this
+ syntax is always paired with an object that uses the JuniSystemLocation
+ syntax.
+ system - all resources on the system
+ slot - all resources associated with a particular slot "
+ SYNTAX INTEGER {
+ system(1),
+ slot(2) }
+
+JuniSystemLocation ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The location instance information that is encoded according to the
+ rules for the associated location information class. An object with
+ this syntax is always paired with an object that uses the
+ JuniSystemLocationType syntax.
+ system - a zero length string: { ''H }
+ slot - a single octet (see juniSystemSlotNumber) "
+ SYNTAX OCTET STRING (SIZE(0..16))
+
+JuniSystemTaskName ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "100a"
+ STATUS current
+ DESCRIPTION
+ "Name of the task. Represents textual information taken from the
+ NVT ASCII character set. The character repertoire of the string is
+ restricted to printable, non-whitespace characters (codes 33 through
+ 126)."
+ REFERENCE
+ "RFC 854: NVT ASCII character set."
+ SYNTAX OCTET STRING (SIZE(1..100))
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- MIB Structure
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemTrap OBJECT IDENTIFIER ::= { juniSystemMIB 0 }
+juniSystemObjects OBJECT IDENTIFIER ::= { juniSystemMIB 1 }
+juniSystemConformance OBJECT IDENTIFIER ::= { juniSystemMIB 2 }
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Managed objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemGeneral OBJECT IDENTIFIER ::= { juniSystemObjects 1 }
+juniSystemSubsystem OBJECT IDENTIFIER ::= { juniSystemObjects 2 }
+juniSystemModule OBJECT IDENTIFIER ::= { juniSystemObjects 3 }
+juniSystemPort OBJECT IDENTIFIER ::= { juniSystemObjects 4 }
+juniSystemTiming OBJECT IDENTIFIER ::= { juniSystemObjects 5 }
+juniSystemFabric OBJECT IDENTIFIER ::= { juniSystemObjects 6 }
+juniSystemNvs OBJECT IDENTIFIER ::= { juniSystemObjects 7 }
+juniSystemPower OBJECT IDENTIFIER ::= { juniSystemObjects 8 }
+juniSystemTemperature OBJECT IDENTIFIER ::= { juniSystemObjects 9 }
+juniSystemUtilization OBJECT IDENTIFIER ::= { juniSystemObjects 10 }
+juniSystemIssu OBJECT IDENTIFIER ::= { juniSystemObjects 11 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- General operational software system objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemSwVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Version identification of currently executing system-wide operational
+ software."
+ ::= { juniSystemGeneral 1 }
+
+juniSystemSwBuildDate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Build date of currently executing system-wide operational software
+ version."
+ ::= { juniSystemGeneral 2 }
+
+juniSystemMemUtilPct OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percentage of memory utilization on the primary system processor. A
+ value of -1 indicates the utilization is unknown."
+ ::= { juniSystemGeneral 3 }
+
+juniSystemMemCapacity OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ UNITS "bytes"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total memory capacity in bytes of the primary system processor. If
+ the memory capacity is greater than 2147483647, a -1 value is returned,
+ and the actual memory capacity (in number of bytes divided by 1024) is
+ returned in juniSystemMemKBytesCapacity."
+ ::= { juniSystemGeneral 4 }
+
+juniSystemMemKBytesCapacity OBJECT-TYPE
+ SYNTAX KBytes
+ UNITS "KBytes"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total memory capacity in kilo-bytes (1024 bytes) of the primary
+ system processor."
+ ::= { juniSystemGeneral 23 }
+
+juniSystemHighMemUtilThreshold OBJECT-TYPE
+ SYNTAX Integer32 (1..99)
+ UNITS "percent"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The value of memory utilization in the primary system processor, where,
+ if reached for the first time after a high memory threshold reset, a
+ high memory utilization event notification will be sent to the
+ management entity on this system. A high memory threshold reset occurs
+ when the system is initialized (booted) or the memory utilization falls
+ below the value in juniSystemAbatedMemUtilThreshold.
+
+ The value of this object must always be greater than the value of
+ juniSystemAbatedMemUtilThreshold."
+ DEFVAL { 85 }
+ ::= { juniSystemGeneral 5 }
+
+juniSystemAbatedMemUtilThreshold OBJECT-TYPE
+ SYNTAX Integer32 (0..98)
+ UNITS "percent"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The value of memory utilization in the primary system processor that is
+ used to determine when to send an abated memory utilization event
+ notification to the management entity on this system. The abated memory
+ utilization event occurs if a high memory threshold reset has not
+ occurred since the last high memory threshold event, and then the memory
+ utilization falls to or below the value of this object. The abated
+ memory utilization event then triggers a high memory threshold reset.
+
+ The value of this object must always be less than the value of
+ juniSystemHighMemUtilThreshold."
+ DEFVAL { 75 }
+ ::= { juniSystemGeneral 6 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- General software system reload configuration objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemBootConfigControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ file(0),
+ fileOnce(1),
+ factoryDefaults(2),
+ runningConfiguration(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System boot configuration control:
+ file - On a system reboot use the configuration
+ settings specified by the
+ juniSystemBootConfigFile. The
+ juniSystemBootConfigControl and
+ juniSystemBootConfigFile must be specified
+ together in the same set request PDU.
+ fileOnce - On the next system reboot use the
+ configuration settings specified by the
+ juniSystemBootConfigFile. Do not continue
+ to use this file after using it once; on
+ subsequent reboots use the running
+ configuration. The
+ juniSystemBootConfigControl and
+ juniSystemBootConfigFile must be specified
+ together in the same set request PDU.
+ factoryDefaults - On the next system reboot use the factory
+ default settings. On subsequent reboots use
+ the running configuration.
+ runningConfiguration - On a system reboot use the current
+ configuration settings."
+ ::= { juniSystemGeneral 7 }
+
+juniSystemBootBackupConfigControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ file(0),
+ factoryDefaults(1),
+ none(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System boot backup configuration control is used to determine the
+ configuration to be used when the boot logic chooses backup mode:
+ file - On a system reboot in backup mode use the
+ configuration settings specified by the
+ juniSystemBootBackupConfigFile. If this option
+ is specified, juniSystemBootBackupConfigFile,
+ juniSystemBootBackupReleaseFile and this object
+ must be specified together in the same set
+ request PDU.
+ factoryDefaults - On a system reboot in backup mode use the
+ factory default configuration settings. If this
+ option is specified,
+ juniSystemBootBackupReleaseFile and this object
+ must be specified together in the same set
+ request PDU.
+ none - Disallow the boot logic from using the backup
+ release file and configuration (i.e., disable
+ backup mode)."
+ ::= { juniSystemGeneral 8 }
+
+juniSystemBootForceBackupControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ on(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System boot force backup control:
+ off - On the next system reboot do not force the boot logic to
+ choose backup mode.
+ on - On the next system reboot force the boot logic to choose
+ backup mode.
+
+ Attempting to set this object to on(1) while the
+ juniSystemBootBackupConfigControl is set to none(2) will result in an
+ error."
+ ::= { juniSystemGeneral 9 }
+
+juniSystemBootAutoRevertControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ default(0),
+ never(1),
+ set(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The system boot auto-revert control is used to determine when the boot
+ logic should choose backup mode based of the reboot history:
+ default - Use the default auto-revert tolerances: 3 reboots in 30
+ minutes.
+ never - Never auto-revert to backup mode.
+ set - Use the auto-revert tolerances specified by
+ juniSystemBootAutoRevertCountTolerance and
+ juniSystemBootAutoRevertTimeTolerance, which must be
+ specified in the same PDU as this object when this value
+ is specified."
+ ::= { juniSystemGeneral 10 }
+
+juniSystemBootAutoRevertCountTolerance OBJECT-TYPE
+ SYNTAX Unsigned32 (0..4294967294)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The auto-revert reboot count tolerance, used in conjunction with the
+ value of juniSystemBootAutoRevertTimeTolerance when
+ juniSystemBootAutoRevertControl is set to set(2) in the same PDU. For
+ example, if this object is set to 4 and
+ juniSystemBootAutoRevertTimeTolerance is set to 1200, then the boot
+ logic will choose backup mode if 4 system reboots occur within 20
+ minutes. This object cannot be set to zero, but may contain a zero
+ value when juniSystemBootAutoRevertControl is set to never(1)."
+ ::= { juniSystemGeneral 11 }
+
+juniSystemBootAutoRevertTimeTolerance OBJECT-TYPE
+ SYNTAX Unsigned32 (0..4294967294)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The auto-revert reboot time tolerance, used in conjunction with the
+ value of juniSystemBootAutoRevertCountTolerance when
+ juniSystemBootAutoRevertControl is set to set(2) in the same PDU. This
+ object cannot be set to zero, but will contain a zero value when
+ juniSystemBootAutoRevertControl is set to never(1)."
+ ::= { juniSystemGeneral 12 }
+
+juniSystemBootReleaseFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The system-wide boot release file name, with extension '.rel'. On a
+ set operation, if there is no file found with the name specified, then
+ an error is returned."
+ ::= { juniSystemGeneral 13 }
+
+juniSystemBootConfigFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The system-wide boot configuration file name. This object and the
+ juniSystemBootConfigControl object set to file(0) or fileOnce(1) must be
+ specified together in the same set request PDU. If
+ juniSystemBootConfigControl is file(0), only file names with extension
+ '.cnf' are allowed. If juniSystemBootConfigControl is fileOnce(1), only
+ file names with extensions '.cnf' or '.scr' are allowed. On a set
+ operation, if the extension is not appropriate or there is no file found
+ with the name specified, then an error is returned. If
+ juniSystemBootConfigControl is not set to file(0) or fileOnce(1) then a
+ get operation for this object will return a zero-length string."
+ DEFVAL { "" }
+ ::= { juniSystemGeneral 14 }
+
+juniSystemBootBackupReleaseFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The system-wide backup boot release file name, with extension '.rel'.
+ A zero-length string indicates that there is no backup release file so
+ the primary release file (juniSystemBootReleaseFile) will be used. On a
+ set operation if there is no file found with the name specified, then an
+ error is returned. The juniSystemBootBackupConfigControl object with a
+ valid value other than none(2) must be specified together with this
+ object in the same set request PDU, and if the
+ juniSystemBootBackupConfigControl is set to file(0) then a valid
+ juniSystemBootBackupConfigFile must also be included in the set request
+ PDU."
+ DEFVAL { "" }
+ ::= { juniSystemGeneral 15 }
+
+juniSystemBootBackupConfigFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The system-wide backup boot configuration file name, with extension
+ '.cnf'. The juniSystemBootBackupReleaseFile object, the
+ juniSystemBootBackupConfigControl object set to file(0), and this object
+ must be specified together in the same set request PDU. On a set
+ operation, if there is no file found with the name specified, then an
+ error is returned. If juniSystemBootBackupConfigControl is not set to
+ file(0) then a get operation for this object will return a zero-length
+ string."
+ DEFVAL { "" }
+ ::= { juniSystemGeneral 16 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- System-wide module redundancy control objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemRedundancyRevertControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ immediate(1),
+ timeOfDay(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Global control for reverting primary modules back from their active
+ redundant spare modules:
+ off - Disable global reverts of redundant modules.
+ immediate - All redundant module pairs are to revert as soon as the
+ primary module is ready to enter the online state.
+ timeOfDay - All redundant module pairs are to revert at the time
+ specified by juniSystemRevertTimeOfDay, relative to
+ midnight based on the system clock time. This object
+ must be set concurrently with juniSystemRevertTimeOfDay
+ when this value is specified.
+
+ Note that this only applies to modules that have
+ juniSystemModuleRedundancySupport set to true(1)."
+ ::= { juniSystemGeneral 17 }
+
+juniSystemRedundancyRevertTimeOfDay OBJECT-TYPE
+ SYNTAX Integer32 (0..86399)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The number of seconds past midnight local time on any given day at
+ which time redundant slot reverts are allowed to occur. This object
+ must be set concurrently with juniSystemRevertControl { timeOfDay }."
+ ::= { juniSystemGeneral 18 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Subsystem objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemSubsystemTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSystemSubsystemEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of subsystems. A subsystem supports a 'family' of module types;
+ that is, each module type is supported by a particular software
+ subsystem. For example, the ERX channelized T1 line card (CT1-FULL) is
+ supported by the 'ct1' subsystem."
+ ::= { juniSystemSubsystem 1 }
+
+juniSystemSubsystemEntry OBJECT-TYPE
+ SYNTAX JuniSystemSubsystemEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table entry containing information pertaining to a subsystem.
+ Subsystem information takes precedence over system-wide information, but
+ not over individual module information."
+ INDEX { juniSystemSubsystemIndex }
+ ::= { juniSystemSubsystemTable 1 }
+
+JuniSystemSubsystemEntry ::= SEQUENCE {
+ juniSystemSubsystemIndex Integer32,
+ juniSystemSubsystemName DisplayString,
+ juniSystemSubsystemBootReleaseFile DisplayString,
+ juniSystemSubsystemBootBackupReleaseFile DisplayString }
+
+juniSystemSubsystemIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Arbitrary subsystem identification number."
+ ::= { juniSystemSubsystemEntry 1 }
+
+juniSystemSubsystemName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The name of the subsystem."
+ ::= { juniSystemSubsystemEntry 2 }
+
+juniSystemSubsystemBootReleaseFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The boot release file name for this subsystem, with extension '.rel'.
+ If a file name is specified (a non-zero-length string), then this
+ release file takes precedence over the system-wide boot release file
+ (juniSystemBootReleaseFile) just for modules of the type specified by
+ the subsystem name. On a set operation, if there is no file that
+ matches the name specified, then an inconsistentValue error will be
+ returned. Setting this object to a zero-length string deconfigures the
+ subsystem-specific backup release file."
+ DEFVAL { "" }
+ ::= { juniSystemSubsystemEntry 3 }
+
+juniSystemSubsystemBootBackupReleaseFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The backup boot release file name for this subsystem, with extension
+ '.rel'. If a file name is specified (a non-zero-length string), then
+ this release file takes precedence over the system-wide boot backup
+ release file (juniSystemBootBackupReleaseFile) just for modules of the
+ type specified by the subsystem name. This object cannot be set unless
+ the system has a backup file, which means that
+ juniSystemBootBackupReleaseFile must contain a file name (a
+ non-zero-length string). On a set operation, if there is no file that
+ matches the name specified, then an inconsistentValue error will be
+ returned. Setting this object to a zero-length string deconfigures the
+ subsystem-specific backup release file."
+ DEFVAL { "" }
+ ::= { juniSystemSubsystemEntry 4 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Module Slot objects
+-- A slot represents a position in a chassis that contains one or more phisical
+-- modules (printed circuit boards) and/or sub-modules that operate together as
+-- a functional unit.
+-- A sub-module is a functionally independent portion of a physical module.
+-- One physical module may contain more than one sub-module.
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemMaxSlotNumber OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The highest number assigned to a slot in the system. In a particular
+ hardware model, module slots have fixed numbers assigned to them, even
+ though in some instances there may be no actual slots associated with a
+ particular number. In all cases there is a maximum slot number that
+ will never be exceeded:
+ 2 for ERX-3xx models
+ 6 for ERX-7xx models
+ 13 for ERX-14xx models
+ 16 for E320 models
+
+ Note that slot numbers are zero-based."
+ ::= { juniSystemModule 1 }
+
+juniSystemMaxModulesPerSlot OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of modules and sub-modules (different levels) that
+ can be associated with a slot number in the system. This value is
+ constant for a particular hardware platform family. The number of
+ levels is 2 for a first generation E-series (ERX) platform and is 4 for
+ a second generation E-series platform.
+
+ For the first generation E-series (ERX) platform family:
+ level 1 - SRP or line card module
+ level 2 - I/O adapter module
+
+ For the second generation E-series platform family:
+ level 1 - Forwarding module or SRP sub-module
+ level 2 - Switch fabric slice (SFS) sub-module or module
+ level 3 - Bay 0 I/O adapter
+ level 4 - Bay 1 I/O adapter "
+ ::= { juniSystemModule 2 }
+
+juniSystemSlotTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSystemSlotEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of system module slot physical container configuration
+ information."
+ ::= { juniSystemModule 3 }
+
+juniSystemSlotEntry OBJECT-TYPE
+ SYNTAX JuniSystemSlotEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table entry describing the physical status of a system module slot
+ container, which is designated by its slot and level positions. There
+ is an entry in this table for all index pairs from { 0, 1 } to the
+ maximum for each index, { juniSystemMaxSlotNumber,
+ juniSystemMaxModulesPerSlot }, even if there is no corresponding module
+ slot container in the system. A request for an index value outside this
+ range will result in a 'no such' response."
+ INDEX { juniSystemSlotNumber,
+ juniSystemSlotLevel }
+ ::= { juniSystemSlotTable 1 }
+
+JuniSystemSlotEntry ::= SEQUENCE {
+ juniSystemSlotNumber Integer32,
+ juniSystemSlotLevel JuniSystemSlotLevel,
+ juniSystemSlotStatus INTEGER,
+ juniSystemSlotType JuniSystemSlotType }
+
+juniSystemSlotNumber OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The slot number. The actual upper limit of valid values is
+ juniSystemMaxSlotNumber. Note that slot numbers are zero-based."
+ ::= { juniSystemSlotEntry 1 }
+
+juniSystemSlotLevel OBJECT-TYPE
+ SYNTAX JuniSystemSlotLevel
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The relative position of a module or sub-module 'container' within a
+ slot."
+ ::= { juniSystemSlotEntry 2 }
+
+juniSystemSlotStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ noSlotContainer(1),
+ empty(2),
+ moduleNotPresent(3),
+ modulePresent(4) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the module slot container.
+ unknown - The existence of a container cannot be
+ determined
+ noSlotContainer - The physical container does not exist
+ empty - No module is present and no configuration
+ information is available for this container
+ moduleNotPresent - A module is configured but it is not currently
+ in its container
+ modulePresent - A module is inserted in the container "
+ ::= { juniSystemSlotEntry 3 }
+
+juniSystemSlotType OBJECT-TYPE
+ SYNTAX JuniSystemSlotType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The category of modules that can be configured for the container."
+ ::= { juniSystemSlotEntry 4 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Module Status objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemModuleTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSystemModuleEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of system module and sub-module information. In this table, a
+ module refers to a physical module (board) or a sub-module.
+
+ A physical board may contain a single module or multiple sub-modules.
+ For example, an ERX line card is a single module and appears as single
+ entry in this table. An I/O adapter is a module that doesn't provide
+ any operaitonal state information and it also appears as a single entry
+ in this table. A second generation E-series SRP/SFS hardware module
+ contains two sub-modules, each with its own operational state
+ information: a System Resource Processor (SRP) sub-module and a Switch
+ Fabric Slice (SFS) sub-module, which appear as two separate entries in
+ this table, one for each sub-module."
+ ::= { juniSystemModule 4 }
+
+juniSystemModuleEntry OBJECT-TYPE
+ SYNTAX JuniSystemModuleEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table entry that provides information about a specific system module
+ or sub-module in a particular module location. There are only entries
+ in this table for module locations that report a juniSystemSlotStatus of
+ moduleNotPresent(3) or modulePresent(4)."
+ INDEX { juniSystemSlotNumber,
+ juniSystemSlotLevel }
+ ::= { juniSystemModuleTable 1 }
+
+JuniSystemModuleEntry ::= SEQUENCE {
+ juniSystemModuleOperStatus INTEGER,
+ juniSystemModuleDisableReason INTEGER,
+ juniSystemModuleLastChange TimeTicks,
+ juniSystemModuleCurrentType JuniSystemModuleType,
+ juniSystemModuleExpectedType JuniSystemModuleType,
+ juniSystemModuleDescr DisplayString,
+ juniSystemModuleSlotSpan Integer32,
+ juniSystemModulePortCount Integer32,
+ juniSystemModuleSerialNumber DisplayString,
+ juniSystemModuleAssemblyPartNumber DisplayString,
+ juniSystemModuleAssemblyRev DisplayString,
+ juniSystemModulePhysicalIndex PhysicalIndex,
+ juniSystemModuleSoftwareSupport TruthValue,
+ juniSystemModuleRedundancySupport TruthValue,
+ juniSystemModuleLevelSpan Integer32 }
+
+juniSystemModuleOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ notPresent(1),
+ disabled(2),
+ hardwareError(3),
+ booting(4),
+ initializing(5),
+ online(6),
+ standby(7),
+ inactive(8),
+ notResponding(9) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current operational status of the module (or sub-module):
+ unknown - The status of the module cannot be determined
+ notPresent - No hardware is currently present but there was a
+ module previously configured in this position (see
+ juniSystemModuleExpectedType);
+ juniSystemModuleCurrentType is unknown(0)
+ disabled - Disable for the reason specified in
+ juniSystemModuleDisableReason
+ hardwareError - Not operational due to a hardware failure
+ booting - In the process of booting
+ initializing - In the process of initialing
+ online - Fully operational
+ standby - In redundant standby mode
+ inactive - In redundant inactive mode
+ notResponding - Unable to communicate with the rest of the system "
+ ::= { juniSystemModuleEntry 1 }
+
+juniSystemModuleDisableReason OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0),
+ unknown(1),
+ assessing(2),
+ admin(3),
+ typeMismatch(4),
+ fabricLimit(5),
+ imageError(6) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the condition causing the module (or sub-module) to be
+ disabled:
+ none - Value when the module is not disabled
+ unknown - Unknown reason for disablement
+ assessing - The module content is being assessed (transient
+ initialization state)
+ admin - The module is administratively disabled
+ typeMismatch - The current module personality conflicts with
+ configuration associated with a different (expected)
+ module personality that previously occupied the slot
+ fabricLimit - Module resource requirements exceed available fabric
+ capacity
+ imageError - Software image for the module is missing or invalid"
+ ::= { juniSystemModuleEntry 2 }
+
+juniSystemModuleLastChange OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when the value of juniSystemModuleOperStatus
+ last changed."
+ ::= { juniSystemModuleEntry 3 }
+
+juniSystemModuleCurrentType OBJECT-TYPE
+ SYNTAX JuniSystemModuleType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The personality of this module based on the combination of modules that
+ are currently inserted in the slot. This could be different from the
+ personality reported in juniSystemModuleExpectedType, in which case it
+ may be necessary to set juniSystemModuleControl for the module in the
+ primary level to 'flush' before the set of modules in this slot can be
+ made operational."
+ ::= { juniSystemModuleEntry 4 }
+
+juniSystemModuleExpectedType OBJECT-TYPE
+ SYNTAX JuniSystemModuleType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The personality for this module position based on the combination of
+ modules that were inserted in this slot when it was last configured.
+ The value of this object will be different than the value of
+ juniSystemModuleCurrentType when the value of juniSystemModuleOperStatus
+ is disabled(2) and the value of juniSystemModuleDisableReason is
+ typeMismatch(4). After one or more modules is removed from a slot,
+ configuration information associated with the slot (its 'personality')
+ may persist, inhibiting the operation of a different combination of
+ modules in the slot (when new modules are inserted) until
+ juniSystemModuleControl for the slot's primary module is set to
+ flush(1)."
+ ::= { juniSystemModuleEntry 5 }
+
+juniSystemModuleDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..63))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Textual description of the expected module in this slot."
+ ::= { juniSystemModuleEntry 6 }
+
+juniSystemModuleSlotSpan OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of slot positions that the expected module spans. Most
+ modules are only one slot wide, but some require extra space or
+ backplane resources. These modules are identified as being in the lower
+ numbered slot and spanning across the higher numbered slot(s)."
+ ::= { juniSystemModuleEntry 7 }
+
+juniSystemModulePortCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of physical ports supported by the expected module type in
+ this slot."
+ ::= { juniSystemModuleEntry 8 }
+
+juniSystemModuleSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..10))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number of the expected module in this slot. The serial
+ number of the current module may be found in this module's
+ entPhysicalSerialNum. A serial number is for a hardware board, so if
+ there is more than one sub-module on a board, their serial numbers will
+ all be the same."
+ DEFVAL { "" }
+ ::= { juniSystemModuleEntry 9 }
+
+juniSystemModuleAssemblyPartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..10))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part number of the expected module in this slot. The part number
+ of the current module may be found in this module's
+ entPhysicalModelName. A part number is for a hardware board, so if
+ there is more than one sub-module on a board, their part numbers will
+ all be the same."
+ DEFVAL { "" }
+ ::= { juniSystemModuleEntry 10 }
+
+juniSystemModuleAssemblyRev OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..3))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The revision level of the expected module in this slot. The revision
+ level of the current module may be found in this module's
+ entPhysicalHardwareRev. A revision level is for a hardware board, so if
+ there is more than one sub-module on a board, their revision levels will
+ all be the same."
+ DEFVAL { "" }
+ ::= { juniSystemModuleEntry 11 }
+
+juniSystemModulePhysicalIndex OBJECT-TYPE
+ SYNTAX PhysicalIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The entPhysicalIndex value assigned to the module. The
+ ENTITY-MIB.entPhysicalTable contains additional information about this
+ module that can be retrieved using this index. An entPhysicalIndex is
+ for a hardware board, so if there is more than one sub-module on a
+ board, their entPhysicalIndex values will all be the same."
+ ::= { juniSystemModuleEntry 12 }
+
+juniSystemModuleSoftwareSupport OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An indicator as to whether this module or sub-module has operational
+ state information that can be managed. If the value of this object is
+ true(1), then there is an entry for this module or sub-module in the
+ juniSystemModuleSoftwareTable."
+ ::= { juniSystemModuleEntry 13 }
+
+juniSystemModuleRedundancySupport OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An indicator as to whether this module or sub-module is part of a
+ redundancy group. If the value of this object is true(1), then there is
+ an entry for this module or sub-module in the
+ juniSystemModuleRedundancyTable."
+ ::= { juniSystemModuleEntry 14 }
+
+juniSystemModuleLevelSpan OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of level positions that the expected module spans. Most
+ modules are only one level 'high', but some require extra space or
+ backplane resources. These modules are identified as being in the lower
+ numbered level and spanning across the higher numbered level(s)."
+ ::= { juniSystemModuleEntry 15 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Module Software objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemModuleSoftwareTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSystemModuleSoftwareEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of system module software information. This includes the
+ version of the software running on the particular module, the running
+ software's use of the modules resources and the modules operational
+ state.
+
+ Some module types don't contain loadable software (they execute
+ 'firmware') but include support for some of the objects in this table.
+ For example, the E320 SFS (es2Sfs) modules only support
+ juniSystemModuleAdminStatus and juniSystemModuleControl. Appropriate
+ 'default' values are returned for the other objects.
+
+ Some module types don't contain any software related information (e.g.,
+ ERX I/O adapters do not) in which case their value of
+ juniSystemModuleSoftwareSupport will be false and there will not be a
+ corresponding entry in this table."
+ ::= { juniSystemModule 5 }
+
+juniSystemModuleSoftwareEntry OBJECT-TYPE
+ SYNTAX JuniSystemModuleSoftwareEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table entry that provides software information about a specific
+ system module in a particular slot location."
+ INDEX { juniSystemSlotNumber,
+ juniSystemSlotLevel }
+ ::= { juniSystemModuleSoftwareTable 1 }
+
+JuniSystemModuleSoftwareEntry ::= SEQUENCE {
+ juniSystemModuleSoftwareVersion DisplayString,
+ juniSystemModuleCpuUtilPct Integer32,
+ juniSystemModuleMemUtilPct Integer32,
+ juniSystemModuleAdminStatus JuniEnable,
+ juniSystemModuleControl INTEGER,
+ juniSystemModuleBootReleaseFile DisplayString,
+ juniSystemModuleBootBackupReleaseFile DisplayString,
+ juniSystemModuleCpuFiveSecUtilPct Integer32,
+ juniSystemModuleCpuOneMinAvgPct Integer32,
+ juniSystemModuleCpuFiveMinAvgPct Integer32 }
+
+juniSystemModuleSoftwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Version identification of the currently executing operational software
+ on this module. If the module is in a state where the software version
+ is not known (e.g., module type mismatch), then the value of this object
+ will be a zero-length string."
+ ::= { juniSystemModuleSoftwareEntry 2 }
+
+juniSystemModuleCpuUtilPct OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Last available module CPU utilization percentage. A value of -1
+ indicates the utilization is unknown. This value is calculated over
+ a 5 second period."
+ ::= { juniSystemModuleSoftwareEntry 3 }
+
+juniSystemModuleMemUtilPct OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percentage of module memory utilization. A value of -1 indicates the
+ utilization is unknown."
+ ::= { juniSystemModuleSoftwareEntry 4 }
+
+juniSystemModuleAdminStatus OBJECT-TYPE
+ SYNTAX JuniEnable
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Provides administrative control to enable/disable the module. This
+ object is read-only for certain types of modules."
+ ::= { juniSystemModuleSoftwareEntry 5 }
+
+juniSystemModuleControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation(0),
+ flush(1),
+ reset(2),
+ resetBackup(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Administrative control of this slot:
+ noOperation - Setting this value has no effect.
+ flush - Flushes the configuration associated with a module
+ type that previously occupied this slot. Used to
+ explicitly confirm that the slot is now empty, or
+ contains a different card type. The module must be
+ disabled when this value is asserted. See the
+ description for juniSystemModuleDisableReason.
+ reset - Resets the module.
+ resetBackup - Resets the module using the backup release file.
+
+ Get operations on this variable always return noOperation. Module types
+ that do not support these operations simply ignore them."
+ ::= { juniSystemModuleSoftwareEntry 6 }
+
+juniSystemModuleBootReleaseFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The boot release file name for this slot, with extension '.rel'. If a
+ file name is specified (not a zero-length string), then this release
+ file takes precedence over the subsystem boot release file
+ (juniSystemSubsystemBootReleaseFile) and the system-wide boot release
+ file (juniSystemBootReleaseFile) for just the module in this slot.
+
+ Some module types (e.g., ERX SRP modules) don't allow this object to be
+ set. On a set operation, if there is no file that matches the name
+ specified, then an inconsistentValue error will be returned. Setting
+ this object to a zero-length string deconfigures the slot-specific
+ primary release file."
+ DEFVAL { "" }
+ ::= { juniSystemModuleSoftwareEntry 7 }
+
+juniSystemModuleBootBackupReleaseFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The backup boot release file name for this slot, with extension '.rel'.
+ If a file name is specified (a non-zero-length string), then this
+ release file takes precedence over the subsystem boot backup release
+ file (juniSystemSubsystemBootBackupReleaseFile) and the system-wide boot
+ backup release file (juniSystemBootBackupReleaseFile) for just the
+ module in this slot.
+
+ This object cannot be set unless the system has a backup file, which
+ mean that juniSystemBootBackupReleaseFile must contain a file name (a
+ non-zero-length string). Some module types (e.g., ERX SRP modules)
+ don't allow this object to be set. On a set operation, if there is no
+ file that matches the name specified, then an inconsistentValue error
+ will be returned. Setting this object to a zero-length string
+ deconfigures the slot-specific backup release file."
+ DEFVAL { "" }
+ ::= { juniSystemModuleSoftwareEntry 8 }
+
+juniSystemModuleCpuFiveSecUtilPct OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percentage of average CPU utilization for the last five sec for this
+ module. A value of -1 indicates the utilization is unknown."
+ ::= { juniSystemModuleSoftwareEntry 9 }
+
+juniSystemModuleCpuOneMinAvgPct OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percentage of average CPU utilization for the last one minute for this
+ module. A value of -1 indicates the utilization is unknown."
+ ::= { juniSystemModuleSoftwareEntry 10 }
+
+juniSystemModuleCpuFiveMinAvgPct OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percentage of average CPU utilization for the last five minutes for
+ this module. A value of -1 indicates the utilization is unknown."
+ ::= { juniSystemModuleSoftwareEntry 11 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Module Redundancy objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemModuleRedundancyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSystemModuleRedundancyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of system module redundancy information. Note that modules
+ that do not support redundancy information will not appear in this
+ table."
+ ::= { juniSystemModule 6 }
+
+juniSystemModuleRedundancyEntry OBJECT-TYPE
+ SYNTAX JuniSystemModuleRedundancyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table entry that provides information about a specific system module
+ in a particular slot location."
+ INDEX { juniSystemSlotNumber,
+ juniSystemSlotLevel }
+ ::= { juniSystemModuleRedundancyTable 1 }
+
+JuniSystemModuleRedundancyEntry ::= SEQUENCE {
+ juniSystemModuleRedundancyGroupId Unsigned32,
+ juniSystemModuleRedundancySpare TruthValue,
+ juniSystemModuleRedundancyAssociatedSlot Integer32,
+ juniSystemModuleRedundancyLockout JuniEnable,
+ juniSystemModuleRedundancyRevertControl INTEGER,
+ juniSystemModuleRedundancyRevertTime DateAndTime }
+
+juniSystemModuleRedundancyGroupId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Identifies the redundancy group as derived from hardware settings."
+ ::= { juniSystemModuleRedundancyEntry 1 }
+
+juniSystemModuleRedundancySpare OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "True only if this module is a spare redundant module."
+ ::= { juniSystemModuleRedundancyEntry 2 }
+
+juniSystemModuleRedundancyAssociatedSlot OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If this module is a primary redundant module, then the module at the
+ same slot level with the slot number identified by this variable is the
+ spare module that serves as this module's backup.
+
+ If this module is an active spare redundant module, then the module in
+ the slot identified by this variable is the primary module for which
+ this module is the spare.
+
+ If this module is an inactive spare redundant module, then the value of
+ this object is the slot number of the spare itself (the same value as
+ the first index)."
+ ::= { juniSystemModuleRedundancyEntry 3 }
+
+juniSystemModuleRedundancyLockout OBJECT-TYPE
+ SYNTAX JuniEnable
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Provides administrative control to enable/disable redundancy protection
+ for the module in this slot."
+ ::= { juniSystemModuleRedundancyEntry 4 }
+
+juniSystemModuleRedundancyRevertControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ immediate(1),
+ timeAndDate(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Per-module control for reverting a primary module back from its active
+ redundant spare module:
+ off - Disable reverting to the primary module.
+ immediate - Revert as soon as this primary module is ready to
+ enter the online state.
+ timeAndDate - Revert to this primary module at time specified by
+ juniSystemModuleRedundancyRevertTime, provided it is
+ in the inactive state.
+
+ This control only applies to primary modules; spare modules can only be
+ set to off(0)."
+ ::= { juniSystemModuleRedundancyEntry 5 }
+
+juniSystemModuleRedundancyRevertTime OBJECT-TYPE
+ SYNTAX DateAndTime (SIZE(8))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The date and time associated with the timeAndDate (delayed) revert
+ operation. Only the local format for DateAndTime is supported. On a
+ set operation, if the time specified is prior to the current time, then
+ an inconsistent value error is returned.This object must be set concurrently
+ with juniSystemModuleRedundancyRevertControl { timeAndDate(2) }."
+ ::= { juniSystemModuleRedundancyEntry 6 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- I/O Port objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSystemPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of system physical I/O ports. The information in this table
+ reflects the ports for the expected module type in each slot; in event
+ of a module mismatch, this table permits navigation of the existing
+ configuration of the expected module type."
+ ::= { juniSystemPort 1 }
+
+juniSystemPortEntry OBJECT-TYPE
+ SYNTAX JuniSystemPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table entry describing a physical port of the system."
+ INDEX { juniSystemSlotNumber,
+ juniSystemSlotLevel,
+ juniSystemPortNumber }
+ ::= { juniSystemPortTable 1 }
+
+JuniSystemPortEntry ::= SEQUENCE {
+ juniSystemPortNumber Integer32,
+ juniSystemPortIfIndex InterfaceIndexOrZero,
+ juniSystemPortPhysicalIndex PhysicalIndex }
+
+juniSystemPortNumber OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Port number of this physical port, relative to the slot in which it
+ resides. Each physical port is uniquely distinguished by its slot
+ number, slot level and port number. Port numbers are zero-based."
+ ::= { juniSystemPortEntry 1 }
+
+juniSystemPortIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ifIndex of the Interfaces MIB ifTable entry corresponding to this
+ physical port; if zero, the ifIndex is unknown or does not exist."
+ ::= { juniSystemPortEntry 2 }
+
+juniSystemPortPhysicalIndex OBJECT-TYPE
+ SYNTAX PhysicalIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The entPhysicalIndex value assigned to this port. This index may be
+ use to retrieve other information about the port, such as description
+ and type, from the ENTITY-MIB.entPhysicalTable."
+ ::= { juniSystemPortEntry 3 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Timing objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemAdminTimingSource OBJECT-TYPE
+ SYNTAX JuniSystemTimingSelector
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The administrative timing source for the system. This variable is used
+ to select the desired timing source to be either primary, secondary or
+ tertiary. Setting this variable will cause the system to change to the
+ specified timing source, provided it is currently available. Setting
+ this value to error(4) is not allowed.
+
+ The system periodically monitors the status of the three timing sources.
+ If the systems current timing source fails, the system will
+ automatically downgrade to the next timing source. If the system is
+ configured to automatically upgrade (juniSystemTimingAutoUpgrade is set
+ to enable(1)) the system will switch back to the timing source indicated
+ by this variable when it becomes available.
+
+ A timing source failure can be detected by comparing the operational and
+ administrative timing sources. If they are not equal, the system has
+ swapped timing sources because the administratively set timing source is
+ in the error state."
+ ::= { juniSystemTiming 1 }
+
+juniSystemOperTimingSource OBJECT-TYPE
+ SYNTAX JuniSystemTimingSelector
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The operational timing source for the system. The system periodically
+ monitors the status of three timing sources, primary, secondary and
+ tertiary. If the systems current timing source fails, the system will
+ automatically downgrade to the next timing source. If the system is
+ configured to automatically upgrade (juniSystemTimingAutoUpgrade is set
+ to enable(1)) the system will switch back to the higher timing source
+ when it becomes available."
+ ::= { juniSystemTiming 2 }
+
+juniSystemTimingAutoUpgrade OBJECT-TYPE
+ SYNTAX JuniEnable
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object controls the automatic timing selector upgrade. Setting
+ this object to disable(0) will prevent automatic upgrade to the next
+ highest timing selector. Setting this object to enable(1) will enable
+ the automatic upgrade of timing selectors."
+ DEFVAL { enable }
+ ::= { juniSystemTiming 3 }
+
+juniSystemTimingSelectorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSystemTimingSelectorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of system timing selectors. This table only contains entries for
+ the primary, secondary and tertiary selecors."
+ ::= { juniSystemTiming 4 }
+
+juniSystemTimingSelectorEntry OBJECT-TYPE
+ SYNTAX JuniSystemTimingSelectorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table entry describing a system timing selector."
+ INDEX { juniSystemTimingSelectorIndex }
+ ::= { juniSystemTimingSelectorTable 1 }
+
+JuniSystemTimingSelectorEntry ::= SEQUENCE {
+ juniSystemTimingSelectorIndex JuniSystemTimingSelector,
+ juniSystemTimingSourceType INTEGER,
+ juniSystemTimingSourceIfIndex InterfaceIndexOrZero,
+ juniSystemTimingSourceLine INTEGER,
+ juniSystemTimingWorkingStatus INTEGER,
+ juniSystemTimingProtectedStatus INTEGER }
+
+juniSystemTimingSelectorIndex OBJECT-TYPE
+ SYNTAX JuniSystemTimingSelector
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The system timing selector index associated with this entry. There are
+ valid indexes for selector types primary(1), secondary(2), tertiary(3)."
+ ::= { juniSystemTimingSelectorEntry 1 }
+
+juniSystemTimingSourceType OBJECT-TYPE
+ SYNTAX INTEGER {
+ timingInterfaceIfIndex(1),
+ timingInternal(2),
+ timingLine(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The system timing source type for this entry. This object must be set
+ to timingInterfaceIfIndex(1) when setting the
+ juniSystemTimingSourceIfIndex object or timingLine(3) when setting the
+ juniSystemTimingSourceLine object. Also, if the value of this object is
+ set to timingInternal(2), no other objects should be set, otherwise the
+ agent will return an error."
+ ::= { juniSystemTimingSelectorEntry 2 }
+
+juniSystemTimingSourceIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The ifIndex of the interface selected as the system timing source. If
+ the juniSystemTimingSourceType object is not timingInterfaceIfIndex(1),
+ then reading this object will return a zero value. The agent will not
+ accept a set to this object unless the juniSystemTimingSourceType object
+ is set to timingInterfaceIfIndex(1)."
+ DEFVAL { 0 }
+ ::= { juniSystemTimingSelectorEntry 3 }
+
+juniSystemTimingSourceLine OBJECT-TYPE
+ SYNTAX INTEGER {
+ timingSourceLineUndefined(0),
+ timingSourceLineE1PortA(1),
+ timingSourceLineE1PortB(2),
+ timingSourceLineT1PortA(3),
+ timingSourceLineT1PortB(4) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The line type timing source for this entry. If the
+ juniSystemTimingSourceType object is not timingLine(3), then reading
+ this object will return timingSourceLineUndefined(0). The agent will
+ not accept a set to this object unless the juniSystemTimingSourceType
+ object is set to timingLine(3). Attempting to set this object to
+ timingSourceLineUndefined(0) will always return an inconsistantValue
+ error. Attempting to set this object to a value that is not supported
+ on the type of system running the agent will result in an
+ inconsistantValue error."
+ DEFVAL { timingSourceLineUndefined }
+ ::= { juniSystemTimingSelectorEntry 4 }
+
+juniSystemTimingWorkingStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ timingStatusOk(1),
+ timingStatusError(2),
+ timingStatusUnknown(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status associated with the working (normal) source of this system
+ timing working selector."
+ ::= { juniSystemTimingSelectorEntry 5 }
+
+juniSystemTimingProtectedStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ timingStatusOk(1),
+ timingStatusError(2),
+ timingStatusUnknown(3),
+ sourceNotProtected(4) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status associated with the protected (backup) source of this system
+ timing selector. If the system doesn't support protected timing
+ sources, then sourceNotProtected(4) will be returned."
+ ::= { juniSystemTimingSelectorEntry 6 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Fabric objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemFabricSpeed OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "gigabits per second"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The speed of switching fabric, in gigabits per second."
+ ::= { juniSystemFabric 1 }
+
+juniSystemFabricRev OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..10))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The fabric revision number. If unknown, a zero-length string is
+ reported."
+ ::= { juniSystemFabric 2 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Non-Volatile Storage status objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemNvsCount OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of non-volatile storage (NVS) 'flash' cards in the system."
+ ::= { juniSystemNvs 1 }
+
+juniSystemNvsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSystemNvsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of NVS status information."
+ ::= { juniSystemNvs 2 }
+
+juniSystemNvsEntry OBJECT-TYPE
+ SYNTAX JuniSystemNvsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table entry that provides the status information for a NVS flash
+ card."
+ INDEX { juniSystemNvsIndex }
+ ::= { juniSystemNvsTable 1 }
+
+JuniSystemNvsEntry ::= SEQUENCE {
+ juniSystemNvsIndex Integer32,
+ juniSystemNvsStatus INTEGER,
+ juniSystemNvsCapacity Unsigned32,
+ juniSystemNvsUtilPct Integer32,
+ juniSystemNvsPhysicalIndex PhysicalIndex }
+
+juniSystemNvsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index number of the NVS flash card. There is an entry in this
+ table for all values of this index in the range of 1 to the value of
+ juniSystemNvsCount."
+ ::= { juniSystemNvsEntry 1 }
+
+juniSystemNvsStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ notPresent(0),
+ writeProtected(1),
+ volumeError(2),
+ nearCapacity(3),
+ ok(4),
+ noConfigSpace(5) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of non-volatile storage (NVS):
+ notPresent - The SRP or the flash card is not accessible.
+ writeProtected - NVS is write-protected.
+ volumeError - Status poll of NVS failed.
+ nearCapacity - Utilization exceeds 85% of NVS capacity.
+ ok - NVS is fully operational with ample capacity.
+ noConfigSpace - Utilization exceeds the ability to save the
+ running configuration."
+ ::= { juniSystemNvsEntry 2 }
+
+juniSystemNvsCapacity OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "megabytes"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The capacity of NVS storage in megabytes."
+ ::= { juniSystemNvsEntry 3 }
+
+juniSystemNvsUtilPct OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The percentage of NVS storage used. A value of -1 indicates NVS
+ utilization is unknown."
+ ::= { juniSystemNvsEntry 4 }
+
+juniSystemNvsPhysicalIndex OBJECT-TYPE
+ SYNTAX PhysicalIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The entPhysicalIndex value assigned to this NVS flash card. This index
+ may be use to retrieve other information about the NVS flash card, such
+ as description and type, from the ENTITY-MIB.entPhysicalTable."
+ ::= { juniSystemNvsEntry 5 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Power element objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemPowerCount OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of power elements in the system."
+ ::= { juniSystemPower 1 }
+
+juniSystemPowerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSystemPowerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of status variables for the system power elements."
+ ::= { juniSystemPower 2 }
+
+juniSystemPowerEntry OBJECT-TYPE
+ SYNTAX JuniSystemPowerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table entry describing status of a system power element."
+ INDEX { juniSystemPowerIndex }
+ ::= { juniSystemPowerTable 1 }
+
+JuniSystemPowerEntry ::= SEQUENCE {
+ juniSystemPowerIndex Integer32,
+ juniSystemPowerStatus INTEGER,
+ juniSystemPowerPhysicalIndex PhysicalIndex }
+
+juniSystemPowerIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index number of the power element. There is an entry in this table
+ for all values of this index in the range of 1 to the value of
+ juniSystemPowerCount."
+ ::= { juniSystemPowerEntry 1 }
+
+juniSystemPowerStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ notPresent(0),
+ inactive(1),
+ good(2),
+ failed(3),
+ sensorFailed(4),
+ unknown(5) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the power element:
+ notPresent - The power element is removed from the chassis.
+ inactive - No power is available from this element.
+ good - Power is available from this element.
+ failed - The power element is not working.
+ sensorFailed - The power element sensor has failed.
+ unknown - The status of the power element is not availiable."
+ ::= { juniSystemPowerEntry 2 }
+
+juniSystemPowerPhysicalIndex OBJECT-TYPE
+ SYNTAX PhysicalIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The entPhysicalIndex value assigned to this power element. This index
+ may be use to retrieve other information about the power element, such
+ as description and type, from the ENTITY-MIB.entPhysicalTable."
+ ::= { juniSystemPowerEntry 3 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Temperature control (fan subsystem) objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemFanCount OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of fan subsystems that may be present in the system.
+ This is a fixed number for each product type."
+ ::= { juniSystemTemperature 1 }
+
+juniSystemFanTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSystemFanEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of status of the system's fan subsystems."
+ ::= { juniSystemTemperature 2 }
+
+juniSystemFanEntry OBJECT-TYPE
+ SYNTAX JuniSystemFanEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table entry describing status of a fan subsystem."
+ INDEX { juniSystemFanIndex }
+ ::= { juniSystemFanTable 1 }
+
+JuniSystemFanEntry ::= SEQUENCE {
+ juniSystemFanIndex Integer32,
+ juniSystemFanStatus INTEGER,
+ juniSystemFanPhysicalIndex PhysicalIndex }
+
+juniSystemFanIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index number of the fan subsystem. This is a number in the range
+ of 1 to the value of juniSystemFanCount."
+ ::= { juniSystemFanEntry 1 }
+
+juniSystemFanStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ failed(0),
+ ok(1),
+ warning(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status of fan subsystem.
+ failed - The fan subsystem has a critical failure, or has been
+ removed, and is now non-operational.
+ ok - All components are operational.
+ warning - The fan subsystem has a non-critical failure."
+ ::= { juniSystemFanEntry 2 }
+
+juniSystemFanPhysicalIndex OBJECT-TYPE
+ SYNTAX PhysicalIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The entPhysicalIndex value assigned to this fan subsystem. This index
+ may be use to retrieve other information about the fan subsystem, such
+ as description and type, from the ENTITY-MIB.entPhysicalTable."
+ ::= { juniSystemFanEntry 3 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Temperature sensor objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemTempCount OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of possible temperature sensors in the system."
+ ::= { juniSystemTemperature 3 }
+
+juniSystemTempTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSystemTempEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of status of the system's temperature sensors."
+ ::= { juniSystemTemperature 4 }
+
+juniSystemTempEntry OBJECT-TYPE
+ SYNTAX JuniSystemTempEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table entry describing status of a temperature sensor. Sensors are
+ located throughout the system. The ENTITY_MIB.entPhysicalTable provides
+ detailed information about the location of each sensor. The index for a
+ table entry is fixed based on a product-specific algorithm that uses the
+ maximum number of sensors that may be on any module type associated with
+ each of the available slots. This means that entries for sensors
+ associated with empty slots and the 'extra' sensors on modules that have
+ less than the maximum number of sensors for the slot type will have a
+ notPresent status."
+ INDEX { juniSystemTempIndex }
+ ::= { juniSystemTempTable 1 }
+
+JuniSystemTempEntry ::= SEQUENCE {
+ juniSystemTempIndex Integer32,
+ juniSystemTempStatus INTEGER,
+ juniSystemTempValue Integer32,
+ juniSystemTempPhysicalIndex Integer32 }
+
+juniSystemTempIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An arbitrary number to uniquely identify the temperature sensor."
+ ::= { juniSystemTempEntry 1 }
+
+juniSystemTempStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ failed(1),
+ tooLow(2),
+ nominal(3),
+ tooHigh(4),
+ tooLowWarning(5),
+ tooHighWarning(6) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of a temperature sensor:
+ unknown - sensor is not present or is not accessible
+ failed - sensor is broken
+ tooLow - temperature is below nominal range
+ nominal - temperature is within nominal range
+ tooHigh - temperature is above nominal range
+ tooLowWarning - temperature is near the nominal lower limit
+ tooHighWarning - temperature is near the nominal upper limit "
+ ::= { juniSystemTempEntry 2 }
+
+juniSystemTempValue OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature measured by this sensor in degrees Celsius. This
+ measurement is valid only if the value of the corresponding
+ juniSystemTempStatus is tooLow, nominal or tooHigh."
+ ::= { juniSystemTempEntry 3 }
+
+juniSystemTempPhysicalIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The entPhysicalIndex value assigned to this temperature sensor. If the
+ temperature sensor is not present this object will return a value of 0.
+ For non-zero values this index may be used to retrieve other information
+ about the temperature sensor from the ENTITY-MIB.entPhysicalTable, such
+ as description and location."
+ ::= { juniSystemTempEntry 4 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Thermal protection objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemTempProtectionStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ monitoring(1),
+ inHoldOff(2),
+ activatedHoldOffExpired(3),
+ activatedTempTooHigh(4) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Thermal Protection status:
+ off - No thermal protection.
+ monitoring - Monitoring.
+ inHoldOff - Hold off time has begun.
+ activatedHoldOffExpired - Hold off time has expired; the system
+ is in thermal protection mode.
+ activatedTempTooHigh - The temperature is too high, the system
+ is in thermal protection mode."
+ ::= { juniSystemTemperature 5 }
+
+juniSystemTempProtectionHoldOffTime OBJECT-TYPE
+ SYNTAX Integer32 (0..1200)
+ UNITS "seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time, in seconds, before the system enters Thermal Protection mode
+ after a critical thermal failure is detected."
+ DEFVAL { 150 }
+ ::= { juniSystemTemperature 6 }
+
+juniSystemTempProtectionHoldOffTimeRemaining OBJECT-TYPE
+ SYNTAX Integer32 (0..1200)
+ UNITS "seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time remaining, in seconds, before the system enters Thermal
+ Protection mode while the ThermalProtectionStatus is set to inHoldOff.
+ The value decrements every second until it reaches zero, and the status
+ changes to activatedHoldOffExpired. When ThermalProtectionStatus is not
+ inHoldOff or activatedHoldOffExpired, the value is set to the hold off
+ time."
+ DEFVAL { 150 }
+ ::= { juniSystemTemperature 7 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Resource utilization objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+--
+-- Resource utilization status table
+--
+juniSystemUtilizationTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSystemUtilizationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of status of the utilization of system resources. It is an
+ implementation option as to which resources (if any) are supported in
+ this table. It is also an implementation option as to whether the
+ threshold objects are supported for a particular instance."
+ ::= { juniSystemUtilization 1 }
+
+juniSystemUtilizationEntry OBJECT-TYPE
+ SYNTAX JuniSystemUtilizationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table entry describing the status of the utilization of a system
+ resource."
+ INDEX { juniSystemUtilizationResourceType,
+ juniSystemUtilizationResourceSubType,
+ juniSystemUtilizationLocationType,
+ juniSystemUtilizationLocation }
+ ::= { juniSystemUtilizationTable 1 }
+
+JuniSystemUtilizationEntry ::= SEQUENCE {
+ juniSystemUtilizationResourceType INTEGER,
+ juniSystemUtilizationResourceSubType Integer32,
+ juniSystemUtilizationLocationType JuniSystemLocationType,
+ juniSystemUtilizationLocation JuniSystemLocation,
+ juniSystemUtilizationMaxCapacity Gauge32,
+ juniSystemUtilizationCurrentValue Gauge32,
+ juniSystemUtilizationThresholdRising Gauge32,
+ juniSystemUtilizationThresholdFalling Gauge32,
+ juniSystemUtilizationHoldDownTime Gauge32 }
+
+juniSystemUtilizationResourceType OBJECT-TYPE
+ SYNTAX INTEGER {
+ interface(1),
+ memory(2) }
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This index identifies a type of enumerated value that is used for the
+ juniSystemUtilizationResourceSubType. See the DESCRIPTION for
+ juniSystemUtilizationResourceSubType for the mapping of Type to SubType
+ enumeration and the corresponding units of measure used for each type of
+ resource."
+ ::= { juniSystemUtilizationEntry 1 }
+
+juniSystemUtilizationResourceSubType OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This index uses an enumerated value that is different for each value of
+ juniSystemUtilizationResourceType. The following table shows the
+ mapping of Type to SubType enumeration and the corresponding units of
+ measure used for each type of resource.
+
+ Type SubType Units
+ -----------+-------------------------------+----------------------------
+ interface Juniper-UNI-IF-MIB.juniIfType number of interfaces
+ memory SNMPv2-TC.StorageType HOST-RESOURCES-MIB.KBytes "
+ ::= { juniSystemUtilizationEntry 2 }
+
+juniSystemUtilizationLocationType OBJECT-TYPE
+ SYNTAX JuniSystemLocationType
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This index element identifies the format of the location information so
+ that the juniSystemUtilizationLocation index element can be properly
+ interpreted."
+ ::= { juniSystemUtilizationEntry 3 }
+
+juniSystemUtilizationLocation OBJECT-TYPE
+ SYNTAX JuniSystemLocation
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This index is used to specify the resource instance based on its
+ location. Its value is interpreted based on the location type
+ identified by the juniSystemUtilizationLocationType index element."
+ ::= { juniSystemUtilizationEntry 4 }
+
+juniSystemUtilizationMaxCapacity OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of units of the resource the system can support.
+
+ See the DESCRIPTION of juniSystemUtilizationResourceSubType for what
+ constitutes a unit of value for this object.
+
+ Note that for some resources this value may not always be achievable due
+ to other resource constraints."
+ ::= { juniSystemUtilizationEntry 5 }
+
+juniSystemUtilizationCurrentValue OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current number of units of the resource in the system.
+
+ See the DESCRIPTION for juniSystemUtilizationResourceSubType for what
+ constitutes a unit of value for this object.
+
+ Note that some resource types may have instances that do not consume any
+ limited resources and therefore are not included in this count (e.g. IP
+ loopback interfaces do not consume routing resources and therefore don't
+ have a capacity limit, whereas 'external' IP interfaces do)."
+ ::= { juniSystemUtilizationEntry 6 }
+
+juniSystemUtilizationThresholdRising OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The threshold value (risingVal), which, in conjunction with
+ juniSystemUtilizationHoldDownTime (holdTime) and
+ juniSystemUtilizationThresholdFalling (fallingVal), is used to decide
+ when to trigger an event indicating that the resource utilization,
+ juniSystemUtilizationCurrentValue (currentVal), is approaching or has
+ reached its maximum capacity, juniSystemUtilizationMaxCapacity (maxVal).
+
+ See the DESCRIPTION for juniSystemUtilizationResourceSubType for what
+ constitutes a unit of value for this object.
+
+ The value of fallingVal must be less than the value of this object.
+
+ This object provides one element in the formula used to determine when
+ to send a utilization notification. If the currentVal rises to equal
+ the risingVal and no other utilization event (either rising or falling)
+ has been triggered within the holdTime, or if the holdTime for a falling
+ threshold notification expires and the currentVal is at or above the
+ risingVal, then and only then is a rising threshold utilization
+ notification sent.
+
+ The following pseudo-code states the algorithm more precisely.
+
+ When the resource is created or initialized ( currentVal == 0 ):
+ lastTrapType = none;
+ lastTrapTime = 0;
+
+ When currentVal increments (increases):
+ if ( currentVal == risingVal &&
+ lastTrapTime + holdTime <= currentTime ) {
+ triggerUtilizationTrapRising();
+ lastTrapType = rising;
+ lastTrapTime = currentTime; }
+
+ When currentVal decrements (decreases):
+ if ( currentVal == fallingVal &&
+ lastTrapTime + holdTime <= currentTime ) {
+ triggerUtilizationTrapFalling();
+ lastTrapType = falling;
+ lastTrapTime = currentTime; }
+
+ When the rising threshold value is modified:
+ if ( currentVal < oldRisingVal &&
+ currentVal >= newRisingVal &&
+ lastTrapTime + holdTime <= currentTime )
+ triggerUtilizationTrapRising();
+ lastTrapType = rising;
+ lastTrapTime = currentTime; }
+
+ When the falling threshold value is modified:
+ if ( currentVal > oldFallingVal &&
+ currentVal <= newFallingVal &&
+ lastTrapTime + holdTime <= currentTime )
+ triggerUtilizationTrapFalling();
+ lastTrapType = falling;
+ lastTrapTime = currentTime; }
+
+ When a hold-down time expires (lastTrapTime + holdTime == currentTime):
+ switch ( lastTrapType ) {
+ case rising:
+ if ( currentVal <= fallingVal ) {
+ triggerUtilizationTrapFalling();
+ lastTrapType = falling;
+ lastTrapTime = currentTime; }
+ else {
+ lastTrapType = none; }
+ break;
+ case falling:
+ if ( currentVal >= risingVal ) {
+ triggerUtilizationTrapRising();
+ lastTrapType = rising;
+ lastTrapTime = currentTime; }
+ else {
+ lastTrapType = none; }
+ break; } "
+ ::= { juniSystemUtilizationEntry 7 }
+
+juniSystemUtilizationThresholdFalling OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The threshold value (fallingVal), which, in conjunction with
+ juniSystemUtilizationHoldDownTime (holdTime) and
+ juniSystemUtilizationThresholdRising (risingVal), is used to decide when
+ to trigger an event indicating that the resource utilization,
+ juniSystemUtilizationCurrentValue (currentVal), has fallen to or below
+ this level after having exceeded this value.
+
+ See the DESCRIPTION for juniSystemUtilizationResourceSubType for what
+ constitutes a unit of value for this object.
+
+ The value of this object must be less than the value of risingVal.
+
+ This object provides one element in the formula used to determine when
+ to send a utilization notification. If the currentVal falls to equal
+ the fallingVal and no other utilization event (either rising or falling)
+ has been triggered within the holdTime, or if the holdTime for a rising
+ threshold notification expires and the currentVal is at or below the
+ fallingVal, then and only then is a falling threshold utilization
+ notification sent.
+
+ The pseudo-code in the juniSystemUtilizationThresholdRising DESCRIPTION
+ states the algorithm more precisely."
+ ::= { juniSystemUtilizationEntry 8 }
+
+juniSystemUtilizationHoldDownTime OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The hold-down time (holdTime) used in conjunction with
+ juniSystemUtilizationThresholdRising (risingVal) and
+ juniSystemUtilizationThresholdFalling (fallingVal) to decide when to
+ trigger an event indicating that the resource utilization,
+ juniSystemUtilizationCurrentValue (currentVal), has reached or surpassed
+ one of the thresholds.
+
+ This object provides one element in the formula used to determine when
+ to send a utilization notification. If the resource utilization
+ increases to the rising threshold value but a prior rising or falling
+ utilization event has been triggered within this hold-down time then no
+ rising threshold utilization notification may be sent at that time. If
+ the resource utilization decreases to the falling threshold value but a
+ prior rising or falling utilization event has been triggered within this
+ hold-down time then no falling threshold utilization notification may be
+ sent at that time. However, if the end of a hold-down period for a
+ rising threshold utilization notification is reached and the current
+ value is at or below the falling threshold value, then a falling
+ threshold notification is sent and the hold-down timer is restarted.
+ Likewise, if the end of a hold-down period for a falling threshold
+ utilization notification is reached and the current value is at or above
+ the rising threshold value, then a rising threshold notification is sent
+ and the hold-down timer is restarted.
+
+ The pseudo-code in the juniSystemUtilizationThresholdRising DESCRIPTION
+ states the algorithm more precisely."
+ ::= { juniSystemUtilizationEntry 9 }
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Task profiling (process cpu utilization) objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemCpuUtilizationTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSystemCpuUtilizationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of status of the cpu utilization by various tasks."
+ ::= { juniSystemUtilization 2 }
+
+juniSystemCpuUtilizationEntry OBJECT-TYPE
+ SYNTAX JuniSystemCpuUtilizationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table entry describing cpu utilization of a particular task."
+ INDEX { juniSystemCpuUtilizationTimeMark,
+ juniSystemCpuUtilizationTaskName }
+ ::= { juniSystemCpuUtilizationTable 1 }
+
+JuniSystemCpuUtilizationEntry ::= SEQUENCE {
+ juniSystemCpuUtilizationTimeMark JuniTimeFilter,
+ juniSystemCpuUtilizationTaskName JuniSystemTaskName,
+ juniSystemCpuUtilizationInvoked Integer32,
+ juniSystemCpuUtilizationInvokationPerSec Integer32,
+ juniSystemCpuUtilizationTotalRunningTime Integer32,
+ juniSystemCpuUtilizationPercentageRunningTime Integer32,
+ juniSystemCpuUtilizationAverageTimePerInvokation Integer32,
+ juniSystemCpuUtilizationFiveSecondUtilization Integer32,
+ juniSystemCpuUtilizationOneMinuteUtilization Integer32,
+ juniSystemCpuUtilizationFiveMinuteUtilization Integer32,
+ juniSystemCpuUtilizationNumberOfInstances Integer32 }
+
+juniSystemCpuUtilizationTimeMark OBJECT-TYPE
+ SYNTAX JuniTimeFilter
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A TimeFilter for this task profile entry. Allows GetNext and GetBulk
+ to find task profile rows which have changed since a specified
+ value of sysUptime."
+ REFERENCE
+ "Refer to RFC 2021 for the definition of the TimeFilter, its usage and
+ implementation notes."
+ ::= { juniSystemCpuUtilizationEntry 1 }
+
+juniSystemCpuUtilizationTaskName OBJECT-TYPE
+ SYNTAX JuniSystemTaskName
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Task name associated with this task profile entry."
+ ::= { juniSystemCpuUtilizationEntry 2 }
+
+juniSystemCpuUtilizationInvoked OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of times task associated with this task profile
+ entry being invoked."
+ ::= { juniSystemCpuUtilizationEntry 3 }
+
+juniSystemCpuUtilizationInvokationPerSec OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Rate of invokation for the task associated with this task
+ profile entry."
+ ::= { juniSystemCpuUtilizationEntry 4 }
+
+juniSystemCpuUtilizationTotalRunningTime OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "milli Seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total running time for the task associated with this task
+ profile entry."
+ ::= { juniSystemCpuUtilizationEntry 5 }
+
+juniSystemCpuUtilizationPercentageRunningTime OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percentage running time for the task associated with this task
+ profile entry."
+ ::= { juniSystemCpuUtilizationEntry 6 }
+
+juniSystemCpuUtilizationAverageTimePerInvokation OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "micro Seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average running time per invokation for the task associated
+ with this task profile entry."
+ ::= { juniSystemCpuUtilizationEntry 7 }
+
+juniSystemCpuUtilizationFiveSecondUtilization OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Utilization in terms of percentage during the five seconds measurement
+ interval for the task associated with this task profile entry."
+ ::= { juniSystemCpuUtilizationEntry 8 }
+
+juniSystemCpuUtilizationOneMinuteUtilization OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Utilization in terms of percentage during the one minute measurement
+ interval for the task associated with this task profile entry."
+ ::= { juniSystemCpuUtilizationEntry 9 }
+
+juniSystemCpuUtilizationFiveMinuteUtilization OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Utilization in terms of percentage during the five minutes measurement
+ interval for the task associated with this task profile entry."
+ ::= { juniSystemCpuUtilizationEntry 10 }
+
+juniSystemCpuUtilizationNumberOfInstances OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of instances consolidated for CPU utilization calculation in this
+ task profile entry."
+ ::= { juniSystemCpuUtilizationEntry 11 }
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- ISSU objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemIssuState OBJECT-TYPE
+ SYNTAX INTEGER {
+ idle(1),
+ initializing(2),
+ initialized(3),
+ upgrading(4),
+ stopping(5) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The state of the system with respect to ISSU upgrade:
+ idle - ISSU is currently idle
+ initializing - ISSU initialization is in-progress
+ initialized - ISSU has successfully initialized
+ upgrading - ISSU is currently upgrading to the new armed release
+ stopping - ISSU is currently in the process of stopping
+
+ This object is supported on the second generation E-series
+ platform family (E320 & E120) in JUNOSe 9.0 and subsequent system
+ releases. This object is also supported on ERX-1440 in JUNOSe 9.2
+ and subsequent system releases."
+ ::= { juniSystemIssu 1 }
+
+juniSystemIssuRunningReleaseFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The currently running release file name, with extension '.rel'.
+ The system was booted last time with this release file.
+
+ This object is supported on the second generation E-series
+ platform family (E320 & E120) in JUNOSe 9.0 and subsequent system
+ releases. This object is also supported on ERX-1440 in JUNOSe 9.2
+ and subsequent system releases."
+ ::= { juniSystemIssu 2 }
+
+juniSystemIssuArmedReleaseFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The currently armed release file name, with extension '.rel'.
+ The system will be booted with this release file, after ISSU (if
+ it is not aborted).
+
+ This object is supported on the second generation E-series
+ platform family (E320 & E120) in JUNOSe 9.0 and subsequent system
+ releases. This object is also supported on ERX-1440 in JUNOSe 9.2
+ and subsequent system releases."
+ ::= { juniSystemIssu 3 }
+
+juniSystemIssuStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(1),
+ warning(2),
+ error(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the system with respect to ISSU upgrade.
+ ok - no error or warning found
+ warning - at least one upgrade warning found, upgrade is possible
+ error - at least one upgrade error found, upgrade is not possible
+
+ This object is supported on the second generation E-series
+ platform family (E320 & E120) in JUNOSe 9.0 and subsequent system
+ releases. This object is also supported on ERX-1440 in JUNOSe 9.2
+ and subsequent system releases."
+ ::= { juniSystemIssu 4 }
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- ISSU upgrade Criteria
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemIssuCriteriaTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSystemIssuCriteriaEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A Table of criteria for an ISSU initialization.
+
+ This table will be empty for unsupported platforms. These objects
+ are supported on the second generation E-series platform
+ family (E320 & E120) in JUNOSe 9.0 and subsequent system releases.
+ This object is also supported on ERX-1440 in JUNOSe 9.2 and
+ subsequent system releases."
+ ::= { juniSystemIssu 5 }
+
+juniSystemIssuCriteriaEntry OBJECT-TYPE
+ SYNTAX JuniSystemIssuCriteriaEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table entry describing the criteria for an ISSU initialization."
+ INDEX { juniSystemIssuCriteriaIndex }
+ ::= { juniSystemIssuCriteriaTable 1 }
+
+ JuniSystemIssuCriteriaEntry ::= SEQUENCE {
+ juniSystemIssuCriteriaIndex Integer32,
+ juniSystemIssuCriteriaDescription DisplayString,
+ juniSystemIssuCriteriaStatus INTEGER }
+
+juniSystemIssuCriteriaIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index associated with an entry of the system ISSU Criteria Table."
+ ::= { juniSystemIssuCriteriaEntry 1 }
+
+juniSystemIssuCriteriaDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "To initialize ISSU, few criteria need to be met. If these criteria
+ were not met, ISSU cannot be initialized. This object provides the
+ criteria details."
+ ::= { juniSystemIssuCriteriaEntry 2 }
+
+juniSystemIssuCriteriaStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(1),
+ no(2),
+ conditional(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "To initialize ISSU, few criteria need to be met. If these criteria
+ were not met, ISSU cannot be initialized. This object indicates
+ whether a criteria has met. It will be conditional when that the
+ user can choose to accept the consequences of proceeding with ISSU
+ with non-ideal operating conditions."
+ ::= { juniSystemIssuCriteriaEntry 3 }
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Notification control objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemMemUtilTrapEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls the sending of primary system processor memory utilization
+ events. Setting the value of this object to true(1) will cause system
+ memory utilization event notifications, if they occur, to be sent to the
+ management entity on this system. Setting the value of this object to
+ false(2) will disable memory utilization event notifications."
+ DEFVAL { false }
+ ::= { juniSystemGeneral 19 }
+
+juniSystemReloadSlotNumber OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "In a juniSystemReloadCommand notification, this object indicates the
+ number of the slot that is being reloaded. Note that slot numbers are
+ zero-based."
+ ::= { juniSystemGeneral 20 }
+
+juniSystemUtilizationThresholdDirection OBJECT-TYPE
+ SYNTAX INTEGER {
+ rising(1),
+ falling(2) }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The type of resource utilization notification being sent. See the
+ DESCRIPTIONs for the juniSystemUtilizationTable elements for details on
+ what conditions trigger a resource utilization notification."
+ ::= { juniSystemGeneral 21 }
+
+juniSystemUtilizationTrapEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls the sending of system resource utilization threshold
+ notifications. Setting the value of this object to true(1) will allow
+ resource utilization threshold event notifications, if they occur, to be
+ sent to the management entity on this system. Setting the value of this
+ object to false(2) will disable resource utilization threshold
+ utilization event notifications."
+ DEFVAL { true }
+ ::= { juniSystemGeneral 22 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Notifications
+--
+-- The juniSystemTrap OBJECT IDENTIFIER is used to define SNMPv2 notifications
+-- that may be translated into SNMPv1 traps.
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemHighMemUtil NOTIFICATION-TYPE
+ OBJECTS {
+ juniSystemMemCapacity,
+ juniSystemMemUtilPct,
+ juniSystemAbatedMemUtilThreshold,
+ juniSystemHighMemUtilThreshold,
+ juniSystemMemKBytesCapacity }
+ STATUS current
+ DESCRIPTION
+ "Report system memory utilization has met the conditions of
+ juniSystemHighMemUtilThreshold. If the memory capacity is greater than
+ 2147483647, a -1 value is returned in juniSystemMemCapacity, and the
+ actual memory capacity in units of 1024 bytes is returned in
+ juniSystemMemKBytesCapacity."
+ ::= { juniSystemTrap 1 }
+
+juniSystemAbatedMemUtil NOTIFICATION-TYPE
+ OBJECTS {
+ juniSystemMemCapacity,
+ juniSystemMemUtilPct,
+ juniSystemAbatedMemUtilThreshold,
+ juniSystemHighMemUtilThreshold,
+ juniSystemMemKBytesCapacity }
+ STATUS current
+ DESCRIPTION
+ "Reports system memory utilization has met the conditions of
+ juniSystemAbatedMemUtilThreshold. If the memory capacity is greater
+ than 2147483647, a -1 value is returned in juniSystemMemCapacity, and
+ the actual memory capacity in units of 1024 bytes is returned in
+ juniSystemMemKBytesCapacity."
+ ::= { juniSystemTrap 2 }
+
+juniSystemModuleOperStatusChange NOTIFICATION-TYPE
+ OBJECTS {
+ juniSystemModuleCurrentType,
+ juniSystemModuleAdminStatus,
+ juniSystemModuleOperStatus,
+ juniSystemModuleDisableReason,
+ juniSystemModuleDescr }
+ STATUS current
+ DESCRIPTION
+ "Reports a status change for a module. This trap is generated on a
+ transition into a stable state (online or disabled) or on a transition
+ out of online. If redundancy is supported for the module
+ (juniSystemModuleRedundancySupported is true(1)), then the
+ juniSystemModuleSpareServer and juniSystemModuleAssociatedSlot objects
+ are also included in the notification."
+ ::= { juniSystemTrap 3 }
+
+juniSystemPowerStatusChange NOTIFICATION-TYPE
+ OBJECTS {
+ entPhysicalDescr,
+ juniSystemPowerStatus }
+ STATUS current
+ DESCRIPTION
+ "Reports a change in the status of a power element."
+ ::= { juniSystemTrap 4 }
+
+juniSystemFanStatusChange NOTIFICATION-TYPE
+ OBJECTS {
+ entPhysicalDescr,
+ juniSystemFanStatus }
+ STATUS current
+ DESCRIPTION
+ "Reports a transition between the three states of the fan subsystem.
+ When the fan subsystem transitions to the failed state the Thermal
+ Protection hold off time begins."
+ ::= { juniSystemTrap 5 }
+
+juniSystemTempStatusChange NOTIFICATION-TYPE
+ OBJECTS {
+ juniSystemTempStatus }
+ STATUS current
+ DESCRIPTION
+ "Reports a change in the temperature status. When the status
+ transitions to the tooHigh state the system enters Thermal Protection
+ mode."
+ ::= { juniSystemTrap 6 }
+
+juniSystemTempProtectionStatusChange NOTIFICATION-TYPE
+ OBJECTS {
+ juniSystemTempProtectionStatus,
+ juniSystemTempProtectionHoldOffTimeRemaining }
+ STATUS current
+ DESCRIPTION
+ "Notification about changes in the state of Thermal Protection. This
+ notification is sent when the tempProtectionStatus changes. It is also
+ sent when the holdOffTimeRemaining is 50% of the holdOffTime."
+ ::= { juniSystemTrap 7 }
+
+juniSystemReloadCommand NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Notification indicating that a slot or the entire system is about to
+ restart due to a system console reload command. If the reload is only
+ on an individual slot then the following object is included in the
+ notification:
+ juniSystemReloadSlotNumber "
+ ::= { juniSystemTrap 8 }
+
+juniSystemUtilizationThreshold NOTIFICATION-TYPE
+ OBJECTS {
+ juniSystemUtilizationThresholdDirection,
+ juniSystemUtilizationMaxCapacity,
+ juniSystemUtilizationCurrentValue,
+ juniSystemUtilizationThresholdRising,
+ juniSystemUtilizationThresholdFalling,
+ juniSystemUtilizationHoldDownTime }
+ STATUS current
+ DESCRIPTION
+ "Notification indicating that a system resource's utilization has met
+ the conditions of juniSystemUtilizationThresholdDirection. See the
+ DESCRIPTIONs for the juniSystemUtilizationTable elements for details on
+ what conditions trigger a resource utilization notification."
+ ::= { juniSystemTrap 9 }
+
+juniSystemIssuStateChange NOTIFICATION-TYPE
+ OBJECTS {
+ juniSystemIssuState }
+ STATUS current
+ DESCRIPTION
+ "Notification about changes in the status, in case of ISSU upgrade.
+ This notification is sent when the juniSystemIssuState changes. The
+ trap parameter will indicate the current value of the
+ juniSystemIssuState.
+
+ This notification is supported on the second generation E-series
+ platform family (E320 & E120) from 9.0 release onwards. This
+ object is also supported on ERX-1440 in JUNOSe 9.2 and
+ subsequent system releases."
+ ::= { juniSystemTrap 10 }
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Conformance information
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSystemCompliances OBJECT IDENTIFIER ::= { juniSystemConformance 1 }
+juniSystemGroups OBJECT IDENTIFIER ::= { juniSystemConformance 2 }
+
+--
+-- compliance statements
+--
+juniSystemCompliance MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete compliance statement for entities that implement the Juniper
+ E-series System MIB. This statement became obsolete when system
+ resource utilization support was added."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniSystemGeneralGroup,
+ juniSystemSubsystemGroup,
+ juniSystemModuleGroup,
+ juniSystemPortGroup,
+ juniSystemTimingGroup,
+ juniSystemFabricGroup,
+ juniSystemNvsGroup,
+ juniSystemPowerGroup,
+ juniSystemTemperatureGroup,
+ juniSystemNotificationObjectsGroup,
+ juniSystemNotificationGroup }
+ ::= { juniSystemCompliances 1 } -- JUNOSe 4.1
+
+juniSystemCompliance2 MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete compliance statement for entities that implement the Juniper
+ E-series System MIB. This statement became obsolete when the system
+ resource utilization trap enabled and the KByte memory capacilty objects
+ were added."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniSystemGeneralGroup,
+ juniSystemSubsystemGroup,
+ juniSystemModuleGroup,
+ juniSystemPortGroup,
+ juniSystemTimingGroup,
+ juniSystemFabricGroup,
+ juniSystemNvsGroup,
+ juniSystemPowerGroup,
+ juniSystemTemperatureGroup,
+ juniSystemUtilizationGroup,
+ juniSystemNotificationObjectsGroup,
+ juniSystemNotificationGroup2 }
+ OBJECT juniSystemUtilizationMaxCapacity
+ MIN-ACCESS accessible-for-notify
+ DESCRIPTION
+ "This object is only required to be included in the
+ juniSystemUtilizationThreshold notifications."
+ OBJECT juniSystemUtilizationCurrentValue
+ MIN-ACCESS accessible-for-notify
+ DESCRIPTION
+ "This object is only required to be included in the
+ juniSystemUtilizationThreshold notifications."
+ OBJECT juniSystemUtilizationThresholdRising
+ MIN-ACCESS accessible-for-notify
+ DESCRIPTION
+ "This object may have a fixed value in a particular
+ implementation and is therefore only required to be included
+ in the juniSystemUtilizationThreshold notifications."
+ OBJECT juniSystemUtilizationThresholdFalling
+ MIN-ACCESS accessible-for-notify
+ DESCRIPTION
+ "This object may have a fixed value in a particular
+ implementation and is therefore only required to be included
+ in the juniSystemUtilizationThreshold notifications."
+ OBJECT juniSystemUtilizationHoldDownTime
+ MIN-ACCESS accessible-for-notify
+ DESCRIPTION
+ "This object may have a fixed value in a particular
+ implementation and is therefore only required to be included
+ in the juniSystemUtilizationThreshold notifications."
+ ::= { juniSystemCompliances 2 } -- JUNOSe 5.0
+
+juniSystemCompliance3 MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete compliance statement for entities that implement the Juniper
+ E-series System MIB. This statement became obsolete when the module
+ level span object was added."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniSystemGeneralGroup2,
+ juniSystemSubsystemGroup,
+ juniSystemModuleGroup,
+ juniSystemPortGroup,
+ juniSystemTimingGroup,
+ juniSystemFabricGroup,
+ juniSystemNvsGroup,
+ juniSystemPowerGroup,
+ juniSystemTemperatureGroup,
+ juniSystemUtilizationGroup,
+ juniSystemNotificationObjectsGroup,
+ juniSystemNotificationGroup2 }
+ ::= { juniSystemCompliances 3 } -- JUNOSe 5.2
+
+juniSystemCompliance4 MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete compliance statement for entities that implement the Juniper
+ E-series System MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniSystemGeneralGroup2,
+ juniSystemSubsystemGroup,
+ juniSystemModuleGroup2,
+ juniSystemPortGroup,
+ juniSystemTimingGroup,
+ juniSystemFabricGroup,
+ juniSystemNvsGroup,
+ juniSystemPowerGroup,
+ juniSystemTemperatureGroup,
+ juniSystemUtilizationGroup,
+ juniSystemNotificationObjectsGroup,
+ juniSystemNotificationGroup2 }
+ ::= { juniSystemCompliances 4 } -- JUNOSe 6.0
+
+juniSystemCompliance5 MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete compliance statement for entities that implement the Juniper
+ E-series System MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniSystemGeneralGroup2,
+ juniSystemSubsystemGroup,
+ juniSystemModuleGroup2,
+ juniSystemPortGroup,
+ juniSystemTimingGroup,
+ juniSystemFabricGroup,
+ juniSystemNvsGroup,
+ juniSystemPowerGroup,
+ juniSystemTemperatureGroup,
+ juniSystemUtilizationGroup2,
+ juniSystemNotificationObjectsGroup,
+ juniSystemNotificationGroup2 }
+ ::= { juniSystemCompliances 5 } -- JUNOSe 7.3
+
+juniSystemCompliance6 MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "The compliance statement for entities that implement the Juniper
+ E-series System MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniSystemGeneralGroup2,
+ juniSystemSubsystemGroup,
+ juniSystemModuleGroup3,
+ juniSystemPortGroup,
+ juniSystemTimingGroup,
+ juniSystemFabricGroup,
+ juniSystemNvsGroup,
+ juniSystemPowerGroup,
+ juniSystemTemperatureGroup,
+ juniSystemUtilizationGroup2,
+ juniSystemNotificationObjectsGroup,
+ juniSystemNotificationGroup2 }
+ ::= { juniSystemCompliances 6 } -- JUNOSe 8.0
+
+juniSystemCompliance7 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for entities that implement the Juniper
+ E-series System MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniSystemGeneralGroup2,
+ juniSystemSubsystemGroup,
+ juniSystemModuleGroup3,
+ juniSystemPortGroup,
+ juniSystemTimingGroup,
+ juniSystemFabricGroup,
+ juniSystemNvsGroup,
+ juniSystemPowerGroup,
+ juniSystemTemperatureGroup,
+ juniSystemUtilizationGroup2,
+ juniSystemNotificationObjectsGroup,
+ juniSystemIssuGroup,
+ juniSystemNotificationGroup3 }
+ ::= { juniSystemCompliances 7 } -- JUNOSe 9.0
+--
+-- units of conformance
+--
+juniSystemGeneralGroup OBJECT-GROUP
+ OBJECTS {
+ juniSystemSwVersion,
+ juniSystemSwBuildDate,
+ juniSystemMemUtilPct,
+ juniSystemMemCapacity,
+ juniSystemHighMemUtilThreshold,
+ juniSystemAbatedMemUtilThreshold,
+ juniSystemMemUtilTrapEnable,
+
+ juniSystemBootConfigControl,
+ juniSystemBootBackupConfigControl,
+ juniSystemBootForceBackupControl,
+ juniSystemBootAutoRevertControl,
+ juniSystemBootAutoRevertCountTolerance,
+ juniSystemBootAutoRevertTimeTolerance,
+ juniSystemBootReleaseFile,
+ juniSystemBootConfigFile,
+ juniSystemBootBackupReleaseFile,
+ juniSystemBootBackupConfigFile,
+
+ juniSystemRedundancyRevertControl,
+ juniSystemRedundancyRevertTimeOfDay }
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete collection of management objects providing system-wide
+ software status and control information in a Juniper E-series product.
+ This group became obsolete when the system resource utilization
+ threshold trap enable/disable and the KByte memory capacilty objects
+ were added."
+ ::= { juniSystemGroups 1 } -- JUNOSe 4.1
+
+juniSystemSubsystemGroup OBJECT-GROUP
+ OBJECTS {
+ juniSystemSubsystemName,
+ juniSystemSubsystemBootReleaseFile,
+ juniSystemSubsystemBootBackupReleaseFile }
+ STATUS current
+ DESCRIPTION
+ "A collection of management objects providing subsystem software control
+ information in a Juniper E-series product."
+ ::= { juniSystemGroups 2 } -- JUNOSe 4.1
+
+juniSystemModuleGroup OBJECT-GROUP
+ OBJECTS {
+ juniSystemMaxSlotNumber,
+ juniSystemMaxModulesPerSlot,
+
+ juniSystemSlotStatus,
+ juniSystemSlotType,
+
+ juniSystemModuleOperStatus,
+ juniSystemModuleDisableReason,
+ juniSystemModuleLastChange,
+ juniSystemModuleCurrentType,
+ juniSystemModuleExpectedType,
+ juniSystemModuleDescr,
+ juniSystemModuleSlotSpan,
+ juniSystemModulePortCount,
+ juniSystemModuleSerialNumber,
+ juniSystemModuleAssemblyPartNumber,
+ juniSystemModuleAssemblyRev,
+ juniSystemModulePhysicalIndex,
+ juniSystemModuleSoftwareSupport,
+ juniSystemModuleRedundancySupport,
+
+ juniSystemModuleSoftwareVersion,
+ juniSystemModuleCpuUtilPct,
+ juniSystemModuleMemUtilPct,
+ juniSystemModuleAdminStatus,
+ juniSystemModuleControl,
+ juniSystemModuleBootReleaseFile,
+ juniSystemModuleBootBackupReleaseFile,
+
+ juniSystemModuleRedundancyGroupId,
+ juniSystemModuleRedundancySpare,
+ juniSystemModuleRedundancyAssociatedSlot,
+ juniSystemModuleRedundancyLockout,
+ juniSystemModuleRedundancyRevertControl,
+ juniSystemModuleRedundancyRevertTime }
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete collection of management objects that provide system module
+ information in a Juniper E-series product. This group became obsolete
+ when the module level span object was added."
+ ::= { juniSystemGroups 3 } -- JUNOSe 4.1
+
+juniSystemPortGroup OBJECT-GROUP
+ OBJECTS {
+ juniSystemPortPhysicalIndex,
+ juniSystemPortIfIndex }
+ STATUS current
+ DESCRIPTION
+ "A collection of management objects providing physical I/O port
+ information in a Juniper E-series product."
+ ::= { juniSystemGroups 4 } -- JUNOSe 4.1
+
+juniSystemTimingGroup OBJECT-GROUP
+ OBJECTS {
+ juniSystemAdminTimingSource,
+ juniSystemOperTimingSource,
+ juniSystemTimingAutoUpgrade,
+
+ juniSystemTimingSourceType,
+ juniSystemTimingSourceIfIndex,
+ juniSystemTimingSourceLine,
+ juniSystemTimingWorkingStatus,
+ juniSystemTimingProtectedStatus }
+ STATUS current
+ DESCRIPTION
+ "A collection of management objects providing system timing source
+ information in a Juniper E-series product."
+ ::= { juniSystemGroups 5 } -- JUNOSe 4.1
+
+juniSystemFabricGroup OBJECT-GROUP
+ OBJECTS {
+ juniSystemFabricSpeed,
+ juniSystemFabricRev }
+ STATUS current
+ DESCRIPTION
+ "A collection of management objects providing system fabric information
+ in a Juniper E-series product."
+ ::= { juniSystemGroups 6 } -- JUNOSe 4.1
+
+juniSystemNvsGroup OBJECT-GROUP
+ OBJECTS {
+ juniSystemNvsCount,
+
+ juniSystemNvsPhysicalIndex,
+ juniSystemNvsStatus,
+ juniSystemNvsCapacity,
+ juniSystemNvsUtilPct }
+ STATUS current
+ DESCRIPTION
+ "A collection of management objects providing system non-volatile
+ storage (NVS) information in a Juniper E-series product."
+ ::= { juniSystemGroups 7 } -- JUNOSe 4.1
+
+juniSystemPowerGroup OBJECT-GROUP
+ OBJECTS {
+ juniSystemPowerCount,
+
+ juniSystemPowerPhysicalIndex,
+ juniSystemPowerStatus }
+ STATUS current
+ DESCRIPTION
+ "A collection of management objects providing system power element
+ information in a Juniper E-series product."
+ ::= { juniSystemGroups 8 } -- JUNOSe 4.1
+
+juniSystemTemperatureGroup OBJECT-GROUP
+ OBJECTS {
+ juniSystemFanCount,
+
+ juniSystemFanPhysicalIndex,
+ juniSystemFanStatus,
+
+ juniSystemTempCount,
+
+ juniSystemTempStatus,
+ juniSystemTempValue,
+ juniSystemTempPhysicalIndex,
+
+ juniSystemTempProtectionStatus,
+ juniSystemTempProtectionHoldOffTime,
+ juniSystemTempProtectionHoldOffTimeRemaining }
+ STATUS current
+ DESCRIPTION
+ "A collection of management objects providing system temperature control
+ information in a Juniper E-series product."
+ ::= { juniSystemGroups 9 } -- JUNOSe 4.1
+
+juniSystemNotificationObjectsGroup OBJECT-GROUP
+ OBJECTS {
+ juniSystemReloadSlotNumber }
+ STATUS current
+ DESCRIPTION
+ "A collection of management objects providing system information for
+ notification in a Juniper E-series product."
+ ::= { juniSystemGroups 10 } -- JUNOSe 4.1
+
+juniSystemNotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ juniSystemHighMemUtil,
+ juniSystemAbatedMemUtil,
+ juniSystemModuleOperStatusChange,
+ juniSystemPowerStatusChange,
+ juniSystemFanStatusChange,
+ juniSystemTempStatusChange,
+ juniSystemTempProtectionStatusChange,
+ juniSystemReloadCommand }
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete collection of notifications for system events in a Juniper
+ E-series product. This group became obsolete when the system resource
+ utilization notification was added."
+ ::= { juniSystemGroups 11 } -- JUNOSe 4.1
+
+juniSystemUtilizationGroup OBJECT-GROUP
+ OBJECTS {
+ juniSystemUtilizationMaxCapacity,
+ juniSystemUtilizationCurrentValue,
+ juniSystemUtilizationThresholdRising,
+ juniSystemUtilizationThresholdFalling,
+ juniSystemUtilizationHoldDownTime,
+ juniSystemUtilizationThresholdDirection }
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete collection of management objects providing system resource
+ utilization information and notification control for a Juniper E-series
+ product."
+ ::= { juniSystemGroups 12 } -- JUNOSe 5.0
+
+juniSystemNotificationGroup2 NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ juniSystemHighMemUtil,
+ juniSystemAbatedMemUtil,
+ juniSystemModuleOperStatusChange,
+ juniSystemPowerStatusChange,
+ juniSystemFanStatusChange,
+ juniSystemTempStatusChange,
+ juniSystemTempProtectionStatusChange,
+ juniSystemReloadCommand,
+ juniSystemUtilizationThreshold }
+ STATUS obsolete
+ DESCRIPTION
+ "A collection of notifications for system events in a Juniper E-series
+ product."
+ ::= { juniSystemGroups 13 } -- JUNOSe 5.0
+
+juniSystemGeneralGroup2 OBJECT-GROUP
+ OBJECTS {
+ juniSystemSwVersion,
+ juniSystemSwBuildDate,
+ juniSystemMemUtilPct,
+ juniSystemMemCapacity,
+ juniSystemMemKBytesCapacity,
+ juniSystemHighMemUtilThreshold,
+ juniSystemAbatedMemUtilThreshold,
+ juniSystemMemUtilTrapEnable,
+ juniSystemUtilizationTrapEnable,
+
+ juniSystemBootConfigControl,
+ juniSystemBootBackupConfigControl,
+ juniSystemBootForceBackupControl,
+ juniSystemBootAutoRevertControl,
+ juniSystemBootAutoRevertCountTolerance,
+ juniSystemBootAutoRevertTimeTolerance,
+ juniSystemBootReleaseFile,
+ juniSystemBootConfigFile,
+ juniSystemBootBackupReleaseFile,
+ juniSystemBootBackupConfigFile,
+
+ juniSystemRedundancyRevertControl,
+ juniSystemRedundancyRevertTimeOfDay }
+ STATUS current
+ DESCRIPTION
+ "A collection of management objects providing system-wide software
+ status and control information in a Juniper E-series product."
+ ::= { juniSystemGroups 14 } -- JUNOSe 5.2
+
+juniSystemModuleGroup2 OBJECT-GROUP
+ OBJECTS {
+ juniSystemMaxSlotNumber,
+ juniSystemMaxModulesPerSlot,
+
+ juniSystemSlotStatus,
+ juniSystemSlotType,
+
+ juniSystemModuleOperStatus,
+ juniSystemModuleDisableReason,
+ juniSystemModuleLastChange,
+ juniSystemModuleCurrentType,
+ juniSystemModuleExpectedType,
+ juniSystemModuleDescr,
+ juniSystemModuleSlotSpan,
+ juniSystemModulePortCount,
+ juniSystemModuleSerialNumber,
+ juniSystemModuleAssemblyPartNumber,
+ juniSystemModuleAssemblyRev,
+ juniSystemModulePhysicalIndex,
+ juniSystemModuleSoftwareSupport,
+ juniSystemModuleRedundancySupport,
+ juniSystemModuleLevelSpan,
+
+ juniSystemModuleSoftwareVersion,
+ juniSystemModuleCpuUtilPct,
+ juniSystemModuleMemUtilPct,
+ juniSystemModuleAdminStatus,
+ juniSystemModuleControl,
+ juniSystemModuleBootReleaseFile,
+ juniSystemModuleBootBackupReleaseFile,
+
+ juniSystemModuleRedundancyGroupId,
+ juniSystemModuleRedundancySpare,
+ juniSystemModuleRedundancyAssociatedSlot,
+ juniSystemModuleRedundancyLockout,
+ juniSystemModuleRedundancyRevertControl,
+ juniSystemModuleRedundancyRevertTime }
+ STATUS obsolete
+ DESCRIPTION
+ "A collection of management objects that provide system module
+ information in a Juniper E-series product."
+ ::= { juniSystemGroups 15 } -- JUNOSe 6.0
+
+juniSystemUtilizationGroup2 OBJECT-GROUP
+ OBJECTS {
+ juniSystemUtilizationMaxCapacity,
+ juniSystemUtilizationCurrentValue,
+ juniSystemUtilizationThresholdRising,
+ juniSystemUtilizationThresholdFalling,
+ juniSystemUtilizationHoldDownTime,
+ juniSystemUtilizationThresholdDirection,
+ juniSystemCpuUtilizationTaskName,
+ juniSystemCpuUtilizationInvoked,
+ juniSystemCpuUtilizationInvokationPerSec,
+ juniSystemCpuUtilizationTotalRunningTime,
+ juniSystemCpuUtilizationPercentageRunningTime,
+ juniSystemCpuUtilizationAverageTimePerInvokation,
+ juniSystemCpuUtilizationFiveSecondUtilization,
+ juniSystemCpuUtilizationOneMinuteUtilization,
+ juniSystemCpuUtilizationFiveMinuteUtilization,
+ juniSystemCpuUtilizationNumberOfInstances }
+ STATUS current
+ DESCRIPTION
+ "A collection of management objects providing system resource
+ utilization information and notification control for a Juniper E-series
+ product."
+ ::= { juniSystemGroups 16 } -- JUNOSe 7.3
+
+juniSystemModuleGroup3 OBJECT-GROUP
+ OBJECTS {
+ juniSystemMaxSlotNumber,
+ juniSystemMaxModulesPerSlot,
+
+ juniSystemSlotStatus,
+ juniSystemSlotType,
+
+ juniSystemModuleOperStatus,
+ juniSystemModuleDisableReason,
+ juniSystemModuleLastChange,
+ juniSystemModuleCurrentType,
+ juniSystemModuleExpectedType,
+ juniSystemModuleDescr,
+ juniSystemModuleSlotSpan,
+ juniSystemModulePortCount,
+ juniSystemModuleSerialNumber,
+ juniSystemModuleAssemblyPartNumber,
+ juniSystemModuleAssemblyRev,
+ juniSystemModulePhysicalIndex,
+ juniSystemModuleSoftwareSupport,
+ juniSystemModuleRedundancySupport,
+ juniSystemModuleLevelSpan,
+
+ juniSystemModuleSoftwareVersion,
+ juniSystemModuleCpuUtilPct,
+ juniSystemModuleMemUtilPct,
+ juniSystemModuleAdminStatus,
+ juniSystemModuleControl,
+ juniSystemModuleBootReleaseFile,
+ juniSystemModuleBootBackupReleaseFile,
+ juniSystemModuleCpuFiveSecUtilPct,
+ juniSystemModuleCpuOneMinAvgPct,
+ juniSystemModuleCpuFiveMinAvgPct,
+
+ juniSystemModuleRedundancyGroupId,
+ juniSystemModuleRedundancySpare,
+ juniSystemModuleRedundancyAssociatedSlot,
+ juniSystemModuleRedundancyLockout,
+ juniSystemModuleRedundancyRevertControl,
+ juniSystemModuleRedundancyRevertTime }
+ STATUS current
+ DESCRIPTION
+ "A collection of management objects that provide system module
+ information in a Juniper E-series product."
+ ::= { juniSystemGroups 17 } -- JUNOSe 8.0
+
+juniSystemIssuGroup OBJECT-GROUP
+ OBJECTS {
+ juniSystemIssuState,
+ juniSystemIssuArmedReleaseFile,
+ juniSystemIssuRunningReleaseFile,
+ juniSystemIssuStatus,
+
+ juniSystemIssuCriteriaDescription,
+ juniSystemIssuCriteriaStatus }
+ STATUS current
+ DESCRIPTION
+ "A collection of management objects that provide ISSU related
+ information in a Juniper E-series product."
+ ::= { juniSystemGroups 18 } -- JUNOSe 9.0
+
+juniSystemNotificationGroup3 NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ juniSystemHighMemUtil,
+ juniSystemAbatedMemUtil,
+ juniSystemModuleOperStatusChange,
+ juniSystemPowerStatusChange,
+ juniSystemFanStatusChange,
+ juniSystemTempStatusChange,
+ juniSystemTempProtectionStatusChange,
+ juniSystemReloadCommand,
+ juniSystemUtilizationThreshold,
+ juniSystemIssuStateChange }
+ STATUS current
+ DESCRIPTION
+ "A collection of notifications for system events in a Juniper E-series
+ product."
+ ::= { juniSystemGroups 19 } -- JUNOSe 9.0
+
+END