summaryrefslogtreecommitdiff
path: root/MIBS/junose/Juniper-System-MIB
blob: e2778432afc89d7b4d37f45ae9e3161214133d7a (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622

-- *****************************************************************************
-- Juniper-System-MIB
--
-- Juniper Networks Enterprise MIB
--   E-series System MIB
--
-- Copyright (c) 2002-2008 Juniper Networks, Inc.  All Rights Reserved.
-- *****************************************************************************

Juniper-System-MIB  DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Unsigned32,
    Gauge32, TimeTicks
        FROM SNMPv2-SMI
    TEXTUAL-CONVENTION, DisplayString, TruthValue, DateAndTime
        FROM SNMPv2-TC
    MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
        FROM SNMPv2-CONF
    PhysicalIndex, entPhysicalDescr
        FROM ENTITY-MIB
    KBytes
        FROM HOST-RESOURCES-MIB
    InterfaceIndexOrZero
        FROM IF-MIB
    juniMibs
        FROM Juniper-MIBs
    JuniEnable, JuniTimeFilter
        FROM Juniper-TC;

juniSystemMIB  MODULE-IDENTITY
    LAST-UPDATED "200806111101Z"  -- 11-Jun-08 07:01 AM EDT
    ORGANIZATION "Juniper Networks, Inc."
    CONTACT-INFO
        "       Juniper Networks, Inc.
        Postal: 10 Technology Park Drive
                Westford, MA  01886-3146
                USA
        Tel:    +1 978 589 5800
        Email:  mib@Juniper.net"
    DESCRIPTION
        "The MIB objects for managing a Juniper E-series (JUNOSe) system.  This
        MIB complements the ENTITY-MIB.entPhysicalTable by providing the
        system's physical information in a format that is more user friendly and
        provides additional elements not found in the Entity MIB, including
        state information, parameters for configuring the system and additional
        notifications.

        There are two families of E-series hardware systems supported by this
        MIB:
            ERX   - first generation E-series systems
            ES2    - second generation E-series systems "
    -- Revision History
    REVISION    "200806111101Z"  -- 11-Jun-08 07:01 AM EDT  - JUNOSe 10.0
    DESCRIPTION
        "Added es2Lm10s support."
    REVISION    "200805051241Z"  -- 05-May-08 08:41 AM EDT  - JUNOSe 9.2
    DESCRIPTION
        "Add ISSU Support for ERX-1440."
    REVISION    "200705071012Z"  -- 07-May-07 06:12 AM EDT  - JUNOSe 9.0
    DESCRIPTION
        "Add ISSU support."
    REVISION    "200612182125Z"  -- 18-Dec-06 04:25 PM EST  - JUNOSe 8.3
    DESCRIPTION
        "Add LM10 Access Support."
    REVISION    "200611240913Z"  -- 24-Nov-06 04:13 AM EST  - JUNOSe 8.2
    DESCRIPTION
        "Add suppot for ES2 primary modules SRP-120 and SFM-120 for E120."
    REVISION    "200605180831Z"  -- 18-May-06 02:01 PM EST  - JUNOSe 8.0
    DESCRIPTION
        "Add last 5 seconds, 1 minute and 5 minutes avergae CPU utilzation
        support."
    REVISION    "200601061817Z"  -- 06-Jan-06 01:17 PM EST  - JUNOSe main
    DESCRIPTION
        "Add LM10 Access Support."
    REVISION    "200512160721Z"  -- 16-Dec-05 12:51 PM EST  - JUNOSe main
    DESCRIPTION
        "Changed maximum value of juniSystemHighMemUtilThreshold from 100 to 99
         and maximum value of juniSystemAbatedMemUtilThreshold from 99 to 98."
    REVISION    "200511182230Z"  -- 18-Nov-05 05:30 PM EST  - JUNOSe 7.3
    DESCRIPTION
        "Add CPU utilization statitics table support."
    REVISION    "200509151414Z"  -- 15-Sep-05 10:14 AM EDT  - JUNOSe 7.2
    DESCRIPTION
        "Add LM10 Uplink Support."
    REVISION    "200508191748Z"  -- 29-Jul-05 01:48 PM EDT  - JUNOSe main
    DESCRIPTION
        "Add Ge8 support."
    REVISION    "200507291748Z"  -- 29-Jul-05 01:48 PM EDT  - JUNOSe 7.0.1
    DESCRIPTION
        "conform to REX Naming Document, renamed various ES2 module types
         and deleted ones that didn't belong."
    REVISION    "200505181810Z"  -- 18-May-05 02:10 PM EDT  - JUNOSe 7.0.0
    DESCRIPTION
        "Updated JuniSystemModuleType TC and created JuniSystemSlotLevel TC."
    REVISION    "200505041810Z"  -- 04-May-05 02:10 PM EDT  - JUNOSe 7.0.0
    DESCRIPTION
        "Added GE-HDE support."
    REVISION    "200501311813Z"  -- 31-Jan-05 02:13 PM EDT  - JUNOSe 5.1.5
    DESCRIPTION
        "Added KByte memory capacity object to notification."
    REVISION    "200412311013Z"  -- 31-Dec-04 05:13 AM EST  - JUNOSe main
    DESCRIPTION
        "Updated for second generation E-series router."

    REVISION    "200412291010Z"  -- 29-Dec-04 05:10 AM EST  - JUNOSe 6.1
    DESCRIPTION
        "Updated SystemTimingSelector TC and related timing objects."
    REVISION    "200405251813Z"  -- 25-May-04 02:13 PM EDT  - JUNOSe 6.1
    DESCRIPTION
        "Added support for the Fe8 FX IOA."
    REVISION    "200401072246Z"  -- 07-Jan-04 05:46 PM EST  - JUNOSe 6.0
    DESCRIPTION
        "Added support for the second generation E-series hardware
        architecture."
    REVISION    "200311242059Z"  -- 24-Nov-03 03:59 PM EST  - JUNOSe 5.3
    DESCRIPTION
        "Added Hybrid Primary Module and Hybrid IOA modules.
         Added GE2 Primary Module and GE2 IOA module."
    REVISION    "200311241939Z"  -- 24-Nov-03 02:39 PM EST  - JUNOSe 5.2
    DESCRIPTION
        "Added resource utilization notification enable/disable.
         Added KByte memory capacilty object."
    REVISION    "200307221410Z"  -- 22-Jul-03 10:10 AM EDT  - JUNOSe 5.1
    DESCRIPTION
        "Added ERX-310 support."
    REVISION    "200301272122Z"  -- 27-Jan-03 04:22 PM EST  - JUNOSe 5.0
    DESCRIPTION
        "Replaced Unisphere names with Juniper names.
         Added resource utilization notification support."
    REVISION    "200210172101Z"  -- 17-Oct-02 05:01 PM EDT  - JUNOSe 4.1
    DESCRIPTION
        "Initial version of this MIB module."
    ::= { juniMibs 2 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Textual conventions
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
JuniSystemModuleType  ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The 'personality' type of a module found in an E-series system.  Some
        primary modules (e.g., line cards) have only one personality; that is
        they only accept one personality of other level modules (e.g. I/O
        adapters) in the same slot and are always configured in the same way.
        Other modules are multi-personality and will behave differently
        depending on the other level modules they are operating with, and
        therefore cannot be configured without knowing the other level module
        type(s).  Type values in this table include both.  Types that are
        multi-personality are noted by [MP] and types that are personality-only
        are noted by [PO].  Use the ENTITY-MIB to deretmine the actual hardware
        type of a module with personality-only type.

            unknown         Unknown module type
        ERX primary modules:
            erxSrp          ERX Switch/Route Processor
            erxCt3          ERX 3 port Channelized T3
            erxOc3          ERX 2 port OC3 SONET/SDH
            erxUt3Atm       ERX 3 port Unchannelized T3 ATM
            erxUt3Frame     ERX 3 port Unchannelized T3 Frame
            erxUe3Atm       ERX 3 port Unchannelized E3 ATM
            erxUe3Frame     ERX 3 port Uncahnnelized E3 Frame
            erxCe1          ERX 20 port Channelized E1
            erxCt1          ERX 24 port Channelized T1
            erxDpfe         ERX 2 port Fast Ethernet
            erxOc12Pos      ERX 1 port OC12 POS
            erxOc12Atm      ERX 1 port OC12 ATM
            erxOc3Pos       ERX 4 port OC3 POS
            erxOc3Atm       ERX 4 port OC3 ATM
            erxGe           ERX 1 port Gigabit Ethernet [PO]
            erxFe8          ERX 8 port Fast Ethernet [PO]
            erxOc3oc12Pos   ERX OC3/OC12 POS [MP]
            erxOc3oc12Atm   ERX OC3/OC12 ATM [MP]
            erxCoc3oc12     ERX Channelized OC3/OC12 [MP]
            erxCoc3         ERX 4 port Channelized OC3 [PO]
            erxCoc12        ERX 1 port Channelized OC12 [PO]
            erxOc12Server   ERX 1 port OC12 Tunnel Server
            erxHssi         ERX 3 port High Speed Serial Interface
            erxGeFe         ERX Gigabit Ethernet / Fast Ethernet [MP]
            erxCt3P12       ERX 12 port Channelized T3
            erxV35          ERX 16 port X.21/V.35
            erxUt3f12       ERX 12 port Unchannelized T3 Frame [PO]
            erxUe3f12       ERX 12 port Unchannelized E3 Frame [PO]
            erxCoc12F3      ERX 1 port OC12 channelized to T3/E3 [PO]
            erxCoc3F3       ERX 4 port OC3 channelized to T3/E3 [PO]
            erxCocxF3       ERX OC3/OC12 channelized to T3/E3 [MP]
            erxVts          ERX Virtual Tunnel Server
            erxOc48         ERX 1 port OC48 SONET/SDH
            erxUt3Atm4      ERX 4 port Unchannelized T3/E3 ATM [PO]
            erxHybrid       ERX ATM / POS / Gigabit Ethernet Hybrid [MP]
            erxOc3AtmGe     ERX 2 port OC3 ATM 1 port Gigabit Ethernet [PO]
            erxOc3AtmPos    ERX 2 port OC3 ATM 2 port OC3 POS [PO]
            erxGe2          ERX 2 port Gigabit Ethernet
            erxGeHde        ERX 2/8 port Gigabit Ethernet
        ERX I/O adapter (IOA) modules:
            erxSrpIoa                 ERX Switch/Route Processor IOA
            erxCt1Ioa                 ERX 24 port channelized T1/J1 IOA
            erxCe1Ioa                 ERX 20 port channelized E1 IOA
            erxCe1TIoa                ERX 20 port channelized E1 Telco IOA
            erxCt3Ioa                 ERX 3 port channelized T3/E3 IOA
            erxE3Ioa                  ERX 3 port E3 IOA
            erxOc3Mm2Ioa              ERX 2 port OC3 multi-mode IOA
            erxOc3Sm2Ioa              ERX 2 port OC3 single-mode IOA
            erxOc3Mm4Ioa              ERX 4 port OC3 multi-mode IOA
            erxOc3SmIr4Ioa            ERX 4 port OC3 single-mode
                                        intermediate-reach IOA
            erxOc3SmLr4Ioa            ERX 4 port OC3 single-mode long-reach IOA
            erxCOc3Mm4Ioa             ERX 4 port channelized OC3 multi-mode IOA
            erxCOc3SmIr4Ioa           ERX 4 port channelized OC3 single-mode
                                        intermediate-reach IOA
            erxCOc3SmLr4Ioa           ERX 4 port channelized OC3 single-mode
                                        long-reach IOA
            erxOc12Mm1Ioa             ERX 1 port OC12 multi-mode IOA
            erxOc12SmIr1Ioa           ERX 1 port OC12 single-mode
                                        intermediate-reach IOA
            erxOc12SmLr1Ioa           ERX 1 port OC12 single-mode long-reach IOA
            erxCOc12Mm1Ioa            ERX 1 port channelized OC12 multi-mode IOA
            erxCOc12SmIr1Ioa          ERX 1 port channelized OC12 single-mode
                                        intermediate-reach IOA
            erxCOc12SmLr1Ioa          ERX 1 port channelized OC12 single-mode
                                        long-reach IOA
            erxFe2Ioa                 ERX 2 port 10/100 Fast Ethernet IOA
            erxFe8Ioa                 ERX 8 port 10/100 Fast Ethernet IOA
            erxGeMm1Ioa               ERX 1 port Gigabit Ethernet multi-mode IOA
            erxGeSm1Ioa               ERX 1 port Gigabit Ethernet single-mode
                                        IOA
            erxHssiIoa                ERX 3 port High Speed Serial Interface IOA
            erxCt3P12Ioa              ERX 12 port channelized and unchannelized
                                        T3 IOA
            erxV35Ioa                 ERX 16 port X2.1/V3.5 IOA
            erxGeSfpIoa               ERX 1 port Gigabit Ethernet SFP IOA
            erxUe3P12Ioa              ERX 12 port unchannelized E3 IOA
            erxT3Atm4Ioa              ERX 4 port T3 ATM IOA
            erxCOc12Mm1ApsIoa         ERX 1 port channelized OC12 multi-mode APS
                                        (1+1) IOA
            erxCOc12SmIr1ApsIoa       ERX 1 port channelized OC12 single-mode
                                        intermediate-reach APS (1+1) IOA
            erxCOc12SmLr1ApsIoa       ERX 1 port channelized OC12 single-mode
                                        long-reach APS (1+1) IOA
            erxOc12Mm1ApsIoa          ERX 1 port OC12 multi-mode APS (1+1) IOA
            erxOc12SmIr1ApsIoa        ERX 1 port OC12 single-mode
                                        intermediate-reach APS (1+1) IOA
            erxOc12SmLr1ApsIoa        ERX 1 port OC12 single-mode long-reach APS
                                        (1+1) IOA
            erxCOc12AtmPosMm1Ioa      ERX 1 port channelized OC12 multi-mode
                                        ATM/POS IOA
            erxCOc12AtmPosSmIr1Ioa    ERX 1 port channelized OC12 single-mode
                                        intermediate-reach ATM/POS IOA
            erxCOc12AtmPosSmLr1Ioa    ERX 1 port channelized OC12 single-mode
                                        long-reach ATM/POS IOA
            erxCOc12AtmPosMm1ApsIoa   ERX 1 port channelized OC12 multi-mode
                                        ATM/POS APS (1+1) IOA
            erxCOc12AtmPosSmIr1ApsIoa ERX 1 port channelized OC12 single-mode
                                        intermediate-reach ATM/POS APS (1+1) IOA
            erxCOc12AtmPosSmLr1ApsIoa ERX 1 port channelized OC12 single-mode
                                        long-reach ATM/POS APS (1+1) IOA
            erxT1E1RedundantIoa       ERX T1/E1 redundant midplane spare IOA
            erxT3E3RedundantIoa       ERX T3/E3 redundant midplane spare IOA
            erxCt3RedundantIoa        ERX channelized T3 redundant midplane
                                        spare IOA
            erxOcxRedundantIoa        ERX OC3/OC12 redundant midplane spare IOA
            erxCOcxRedundantIoa       ERX channelized OC3/OC12 redundant
                                        midplane spare IOA
            erxOc3Mm4ApsIoa           ERX 4 port OC3 multi-mode APS (1+1) IOA
            erxOc3SmIr4ApsIoa         ERX 4 port OC3 single-mode
                                        intermediate-reach APS (1+1) IOA
            erxOc3SmLr4ApsIoa         ERX 4 port OC3 single-mode long-reach APS
                                        (1+1) IOA
            erxOc48Ioa                ERX 1 port OC48/STM16 IOA
            erxOc3Atm2Ge1Ioa          ERX 2 port OC3 ATM 1 port GE IOA
            erxOc3Atm2Pos2Ioa         ERX 2 port OC3 ATM 2 port OC3 POS IOA
            erxGe2Ioa                 ERX 2 port Gigabit Ethernet IOA
            erxFe8FxIoa               ERX 8 port 100 Fast Ethernet SFP IOA
            erxGe8Ioa                 ERX 8 port Gigabit Ethernet IOA
        ES2 primary modules:
            e320Srp100                 ES2 100Gb System Route Processor with integrated
                                        fabric slice
            e320Sfm100                 ES2 100Gb Switch Fabric Slice
            es2Lm4                     ES2 4Gb (series 1) Line Module(LM).  
            es2Lm10Uplink              ES2 10Gb (series 2) Uplink Line Module(LM).  
            es2Lm10                    ES2 10Gb (series 3) Line Module(LM).  
            e320Srp320                 ES2 320Gb System Route Processor with integrated
                                        fabric slice
            e320Sfm320                 ES2 320Gb Switch Fabric Slice
            es2Lm10s                   ES2 10Gb (series 4) Line Module(LM).  
        ES2 I/O adapter (IOA) modules:
            e320SrpIoa                 ES2 system resource processor IOA
            es2Ge4S1Ioa                ES2 4 port Gigabit Ethernet S1 IOA
            es2Oc48Stm16PosS1Ioa       ES2 OC48/STM16 POS S1 IOA
            es2ServiceS1Ioa            ES2 Service S1 IOA
            es2Oc3Stm1x8AtmS1Ioa       ES2 OC3/STM1-8 ATM S1 IOA
            es2RedundancyS1Ioa         ES2 Redundancy S1 IOA
            es2Oc12Stm4x2PosS1Ioa      ES2 OC12/STM4-2 POS S1 IOA
            es2Oc12Stm4x2AtmS1Ioa      ES2 OC12/STM4-2 ATM S1 IOA
            es2dash10GeS1Ioa           ES2 10GE-1 SR S1 IOA
            es2Ge8S1Ioa                ES2 8 port Gigabit Ethernet S1 IOA
            es2dash10GePrS2Ioa         ES2 10GE-1 Port Redundancy S2 IOA
            es2Ge20S2Ioa               ES2 20 port Gigabit Ethernet S2 IOA
        ES2 primary modules for E120:
            e120Srp120                 ES2 120Gb System Route Processor with integrated
                                        fabric slice
            e120Sfm120                 ES2 120Gb Switch Fabric Slice"


    SYNTAX      INTEGER {
                    unknown(0),
                -- ERX primary module types
                    erxSrp(1),
                    erxCt3(2),
                    erxOc3(3),
                    erxUt3Atm(4),
                    erxUt3Frame(5),
                    erxUe3Atm(6),
                    erxUe3Frame(7),
                    erxCe1(8),
                    erxCt1(9),
                    erxDpfe(10),
                    erxOc12Pos(11),
                    erxOc12Atm(12),
                    erxOc3Pos(13),
                    erxOc3Atm(14),
                    erxGe(15),
                    erxFe8(16),
                    erxOc3oc12Pos(17),
                    erxOc3oc12Atm(18),
                    erxCoc3oc12(19),
                    erxCoc3(20),
                    erxCoc12(21),
                    erxOc12Server(22),
                    erxHssi(23),
                    erxGeFe(24),
                    erxCt3P12(25),
                    erxV35(26),
                    erxUt3f12(27),
                    erxUe3f12(28),
                    erxCoc12F3(29),
                    erxCoc3F3(30),
                    erxCocxF3(31),
                    erxVts(32),
                    erxOc48(33),
                    erxUt3Atm4(34),
                    erxHybrid(35),
                    erxOc3AtmGe(36),
                    erxOc3AtmPos(37),
                    erxGe2(38),
                    erxGeHde(39),
                -- ERX I/O adapter (IOA) module types
                    erxSrpIoa(1024),
                    erxCt1Ioa(1025),
                    erxCe1Ioa(1026),
                    erxCe1TIoa(1027),
                    erxCt3Ioa(1028),
                    erxE3Ioa(1029),
                    erxOc3Mm2Ioa(1030),
                    erxOc3Sm2Ioa(1031),
                    erxOc3Mm4Ioa(1032),
                    erxOc3SmIr4Ioa(1033),
                    erxOc3SmLr4Ioa(1034),
                    erxCOc3Mm4Ioa(1035),
                    erxCOc3SmIr4Ioa(1036),
                    erxCOc3SmLr4Ioa(1037),
                    erxOc12Mm1Ioa(1038),
                    erxOc12SmIr1Ioa(1039),
                    erxOc12SmLr1Ioa(1040),
                    erxCOc12Mm1Ioa(1041),
                    erxCOc12SmIr1Ioa(1042),
                    erxCOc12SmLr1Ioa(1043),
                    erxFe2Ioa(1044),
                    erxFe8Ioa(1045),
                    erxGeMm1Ioa(1046),
                    erxGeSm1Ioa(1047),
                    erxHssiIoa(1048),
                    erxCt3P12Ioa(1049),
                    erxV35Ioa(1050),
                    erxGeSfpIoa(1051),
                    erxUe3P12Ioa(1052),
                    erxT3Atm4Ioa(1053),
                    erxCOc12Mm1ApsIoa(1054),
                    erxCOc12SmIr1ApsIoa(1055),
                    erxCOc12SmLr1ApsIoa(1056),
                    erxOc12Mm1ApsIoa(1057),
                    erxOc12SmIr1ApsIoa(1058),
                    erxOc12SmLr1ApsIoa(1059),
                    erxCOc12AtmPosMm1Ioa(1060),
                    erxCOc12AtmPosSmIr1Ioa(1061),
                    erxCOc12AtmPosSmLr1Ioa(1062),
                    erxCOc12AtmPosMm1ApsIoa(1063),
                    erxCOc12AtmPosSmIr1ApsIoa(1064),
                    erxCOc12AtmPosSmLr1ApsIoa(1065),
                    erxT1E1RedundantIoa(1066),
                    erxT3E3RedundantIoa(1067),
                    erxCt3RedundantIoa(1068),
                    erxOcxRedundantIoa(1069),
                    erxCOcxRedundantIoa(1070),
                    erxOc3Mm4ApsIoa(1071),
                    erxOc3SmIr4ApsIoa(1072),
                    erxOc3SmLr4ApsIoa(1073),
                    erxOc48Ioa(1074),
                    erxOc3Atm2Ge1Ioa(1075),
                    erxOc3Atm2Pos2Ioa(1076),
                    erxGe2Ioa(1077),
                    erxFe8FxIoa(1078),
                    erxGe8Ioa(1079),
                -- ES2 primary module types
                    e320Srp100(2048),
                    e320Sfm100(2049),
                    es2Lm4(2050),
                    es2Lm10Uplink(2051),
                    es2Lm10(2052),
                    e320Srp320(2053),
                    e320Sfm320(2054),
                    es2Lm10s(2055),
                -- ES2 I/O adapter (IOA) module types
                    e320SrpIoa(3072),
                    es2Ge4S1Ioa(3073),
                    es2Oc48Stm16PosS1Ioa(3074),
                    es2ServiceS1Ioa(3075),
                    es2Oc3Stm1x8AtmS1Ioa(3076),
                    es2RedundancyS1Ioa(3077),
                    es2Oc12Stm4x2PosS1Ioa(3078),
                    es2Oc12Stm4x2AtmS1Ioa(3079),
                    es2dash10GeS1Ioa(3080),
                    es2Ge8S1Ioa(3081),
                    es2dash10GePrS2Ioa(3082),
                    es2Ge20S2Ioa(3083) ,
                -- ES2 primary module types for E120
                    e120Srp120(4096),
                    e120Sfm120(4097) }

JuniSystemSlotLevel  ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The relative position of a module or sub-module 'container' within a
        slot.  The upper limit of valid values is juniSystemMaxModulesPerSlot.
        A module or sub-module in the lowest numbered level for a particular
        slot is considered to be the 'primary' module for that slot.

        For the first generation E-series (ERX) platform family:
            level 1 - SRP or line card module
            level 2 - I/O adapter module

        For the second generation E-series platform family:
            level 1 - Forwarding module or SRP sub-module
            level 2 - Switch fabric slice (SFS) sub-module or module
            level 3 - Bay 0 I/O adapter
            level 4 - Bay 1 I/O adapter "

    SYNTAX      Integer32 (1..4)
 
JuniSystemSlotType  ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The type of 'container' for holding a module or sub-module found in an
        E-series chassis.

        The slot type may be for a 'sub-module' where there are multiple logical
        functions on a single hardware module.  For example, the second
        generation SRP hardware module (slot 6 or 7 on an E320) contains both a
        System Resource Processor (SRP) sub-module (level 1 position) and a
        Switch Fabric Slice (SFS) sub-module (level 2 position).

            noSlot          The slot does not exist
        ERX system slot types:
            erxSrpSlot      ERX switch/route processor module slot
            erxLcmSlot      ERX line card module slot
            erxSrpIoaSlot   ERX switch/route processor I/O adapter slot
            erxLcIoaSlot    ERX line card I/O adapter slot
        Second generation E-series (ES2) system slot types:
            es2SrpSlot       ES2 system resource processor sub-module slot
            es2SfsSlot       ES2 switch fabric module or sub-module slot
            es2FmSlot        ES2 forwarding module slot
            es2SrpIoaSlot    ES2 system resource processor I/O adapter slot
            es2FIoaSlot      ES2 forwarding I/O adapter slot "
    SYNTAX      INTEGER {
                    noSlot(0),
                -- ERX system slot types
                    erxSrpSlot(1),
                    erxLcmSlot(2),
                    erxSrpIoaSlot(3),
                    erxLcIoaSlot(4),
                -- ES2 system slot types
                    es2SrpSlot(16),
                    es2SfsSlot(17),
                    es2FmSlot(18),
                    es2SrpIoaSlot(19),
                    es2FIoaSlot(20) }

JuniSystemTimingSelector  ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The system timing selector.
            primary   - the primary timing selector
            secondary - the secondary timing selector
            tertiary  - the tertiary timing selector
            error     - the error in timing selector"
    SYNTAX      INTEGER  {
                    primary(1),
                    secondary(2),
                    tertiary(3),
                    error(4)}

JuniSystemLocationType  ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The location information class that is used to understand the encoding
        of the associated location instance information.  An object with this
        syntax is always paired with an object that uses the JuniSystemLocation
        syntax.
            system    - all resources on the system
            slot      - all resources associated with a particular slot "
    SYNTAX      INTEGER {
                    system(1),
                    slot(2) }

JuniSystemLocation  ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The location instance information that is encoded according to the
        rules for the associated location information class.  An object with
        this syntax is always paired with an object that uses the
        JuniSystemLocationType syntax.
            system    - a zero length string: { ''H }
            slot      - a single octet (see juniSystemSlotNumber) "
    SYNTAX      OCTET STRING (SIZE(0..16))

JuniSystemTaskName  ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "100a"
    STATUS      current
    DESCRIPTION
        "Name of the task. Represents textual information taken from the
        NVT ASCII character set. The character repertoire of the string is
        restricted to printable, non-whitespace characters (codes 33 through
        126)."
    REFERENCE
        "RFC 854: NVT ASCII character set."
    SYNTAX      OCTET STRING (SIZE(1..100))
    
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- MIB Structure
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemTrap          OBJECT IDENTIFIER ::= { juniSystemMIB 0 }
juniSystemObjects       OBJECT IDENTIFIER ::= { juniSystemMIB 1 }
juniSystemConformance   OBJECT IDENTIFIER ::= { juniSystemMIB 2 }

-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Managed objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemGeneral        OBJECT IDENTIFIER ::= { juniSystemObjects 1 }
juniSystemSubsystem      OBJECT IDENTIFIER ::= { juniSystemObjects 2 }
juniSystemModule         OBJECT IDENTIFIER ::= { juniSystemObjects 3 }
juniSystemPort           OBJECT IDENTIFIER ::= { juniSystemObjects 4 }
juniSystemTiming         OBJECT IDENTIFIER ::= { juniSystemObjects 5 }
juniSystemFabric         OBJECT IDENTIFIER ::= { juniSystemObjects 6 }
juniSystemNvs            OBJECT IDENTIFIER ::= { juniSystemObjects 7 }
juniSystemPower          OBJECT IDENTIFIER ::= { juniSystemObjects 8 }
juniSystemTemperature    OBJECT IDENTIFIER ::= { juniSystemObjects 9 }
juniSystemUtilization    OBJECT IDENTIFIER ::= { juniSystemObjects 10 }
juniSystemIssu           OBJECT IDENTIFIER ::= { juniSystemObjects 11 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- General operational software system objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemSwVersion  OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Version identification of currently executing system-wide operational
        software."
    ::= { juniSystemGeneral 1 }

juniSystemSwBuildDate  OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Build date of currently executing system-wide operational software
        version."
    ::= { juniSystemGeneral 2 }

juniSystemMemUtilPct  OBJECT-TYPE
    SYNTAX      Integer32 (-1..100)
    UNITS       "percent"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Percentage of memory utilization on the primary system processor.  A
        value of -1 indicates the utilization is unknown."
    ::= { juniSystemGeneral 3 }

juniSystemMemCapacity  OBJECT-TYPE
    SYNTAX      Integer32 (-1..2147483647)
    UNITS       "bytes"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The total memory capacity in bytes of the primary system processor.  If
        the memory capacity is greater than 2147483647, a -1 value is returned,
        and the actual memory capacity (in number of bytes divided by 1024) is
        returned in juniSystemMemKBytesCapacity."
    ::= { juniSystemGeneral 4 }

juniSystemMemKBytesCapacity  OBJECT-TYPE
    SYNTAX      KBytes
    UNITS       "KBytes"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The total memory capacity in kilo-bytes (1024 bytes) of the primary
        system processor."
    ::= { juniSystemGeneral 23 }

juniSystemHighMemUtilThreshold  OBJECT-TYPE
    SYNTAX      Integer32 (1..99)
    UNITS       "percent"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of memory utilization in the primary system processor, where,
        if reached for the first time after a high memory threshold reset, a
        high memory utilization event notification will be sent to the
        management entity on this system.  A high memory threshold reset occurs
        when the system is initialized (booted) or the memory utilization falls
        below the value in juniSystemAbatedMemUtilThreshold.

        The value of this object must always be greater than the value of
        juniSystemAbatedMemUtilThreshold."
    DEFVAL    { 85 }
    ::= { juniSystemGeneral 5 }

juniSystemAbatedMemUtilThreshold  OBJECT-TYPE
    SYNTAX      Integer32 (0..98)
    UNITS       "percent"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of memory utilization in the primary system processor that is
        used to determine when to send an abated memory utilization event
        notification to the management entity on this system.  The abated memory
        utilization event occurs if a high memory threshold reset has not
        occurred since the last high memory threshold event, and then the memory
        utilization falls to or below the value of this object.  The abated
        memory utilization event then triggers a high memory threshold reset.

        The value of this object must always be less than the value of
        juniSystemHighMemUtilThreshold."
    DEFVAL    { 75 }
    ::= { juniSystemGeneral 6 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- General software system reload configuration objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemBootConfigControl  OBJECT-TYPE
    SYNTAX      INTEGER {
                    file(0),
                    fileOnce(1),
                    factoryDefaults(2),
                    runningConfiguration(3) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "System boot configuration control:
            file                  - On a system reboot use the configuration
                                    settings specified by the
                                    juniSystemBootConfigFile.  The
                                    juniSystemBootConfigControl and
                                    juniSystemBootConfigFile must be specified
                                    together in the same set request PDU.
            fileOnce              - On the next system reboot use the
                                    configuration settings specified by the
                                    juniSystemBootConfigFile.  Do not continue
                                    to use this file after using it once; on
                                    subsequent reboots use the running
                                    configuration.  The
                                    juniSystemBootConfigControl and
                                    juniSystemBootConfigFile must be specified
                                    together in the same set request PDU.
            factoryDefaults       - On the next system reboot use the factory
                                    default settings.  On subsequent reboots use
                                    the running configuration.
            runningConfiguration  - On a system reboot use the current
                                    configuration settings."
    ::= { juniSystemGeneral 7 }

juniSystemBootBackupConfigControl  OBJECT-TYPE
    SYNTAX      INTEGER {
                    file(0),
                    factoryDefaults(1),
                    none(2) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "System boot backup configuration control is used to determine the
        configuration to be used when the boot logic chooses backup mode:
            file              - On a system reboot in backup mode use the
                                configuration settings specified by the
                                juniSystemBootBackupConfigFile.  If this option
                                is specified, juniSystemBootBackupConfigFile,
                                juniSystemBootBackupReleaseFile and this object
                                must be specified together in the same set
                                request PDU.
            factoryDefaults   - On a system reboot in backup mode use the
                                factory default configuration settings.  If this
                                option is specified,
                                juniSystemBootBackupReleaseFile and this object
                                must be specified together in the same set
                                request PDU.
            none              - Disallow the boot logic from using the backup
                                release file and configuration (i.e., disable
                                backup mode)."
    ::= { juniSystemGeneral 8 }

juniSystemBootForceBackupControl  OBJECT-TYPE
    SYNTAX      INTEGER {
                    off(0),
                    on(1) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "System boot force backup control:
            off   - On the next system reboot do not force the boot logic to
                    choose backup mode.
            on    - On the next system reboot force the boot logic to choose
                    backup mode.

        Attempting to set this object to on(1) while the
        juniSystemBootBackupConfigControl is set to none(2) will result in an
        error."
    ::= { juniSystemGeneral 9 }

juniSystemBootAutoRevertControl  OBJECT-TYPE
    SYNTAX      INTEGER {
                    default(0),
                    never(1),
                    set(2) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The system boot auto-revert control is used to determine when the boot
        logic should choose backup mode based of the reboot history:
            default   - Use the default auto-revert tolerances: 3 reboots in 30
                        minutes.
            never     - Never auto-revert to backup mode.
            set       - Use the auto-revert tolerances specified by
                        juniSystemBootAutoRevertCountTolerance and
                        juniSystemBootAutoRevertTimeTolerance, which must be
                        specified in the same PDU as this object when this value
                        is specified."
    ::= { juniSystemGeneral 10 }

juniSystemBootAutoRevertCountTolerance  OBJECT-TYPE
    SYNTAX      Unsigned32 (0..4294967294)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The auto-revert reboot count tolerance, used in conjunction with the
        value of juniSystemBootAutoRevertTimeTolerance when
        juniSystemBootAutoRevertControl is set to set(2) in the same PDU.  For
        example, if this object is set to 4 and
        juniSystemBootAutoRevertTimeTolerance is set to 1200, then the boot
        logic will choose backup mode if 4 system reboots occur within 20
        minutes.  This object cannot be set to zero, but may contain a zero
        value when juniSystemBootAutoRevertControl is set to never(1)."
    ::= { juniSystemGeneral 11 }

juniSystemBootAutoRevertTimeTolerance  OBJECT-TYPE
    SYNTAX      Unsigned32 (0..4294967294)
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The auto-revert reboot time tolerance, used in conjunction with the
        value of juniSystemBootAutoRevertCountTolerance when
        juniSystemBootAutoRevertControl is set to set(2) in the same PDU.  This
        object cannot be set to zero, but will contain a zero value when
        juniSystemBootAutoRevertControl is set to never(1)."
    ::= { juniSystemGeneral 12 }

juniSystemBootReleaseFile  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..128))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The system-wide boot release file name, with extension '.rel'.  On a
        set operation, if there is no file found with the name specified, then
        an error is returned."
    ::= { juniSystemGeneral 13 }

juniSystemBootConfigFile  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..128))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The system-wide boot configuration file name.  This object and the
        juniSystemBootConfigControl object set to file(0) or fileOnce(1) must be
        specified together in the same set request PDU.  If
        juniSystemBootConfigControl is file(0), only file names with extension
        '.cnf' are allowed.  If juniSystemBootConfigControl is fileOnce(1), only
        file names with extensions '.cnf' or '.scr' are allowed.  On a set
        operation, if the extension is not appropriate or there is no file found
        with the name specified, then an error is returned.  If
        juniSystemBootConfigControl is not set to file(0) or fileOnce(1) then a
        get operation for this object will return a zero-length string."
    DEFVAL    { "" }
    ::= { juniSystemGeneral 14 }

juniSystemBootBackupReleaseFile  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..128))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The system-wide backup boot release file name, with extension '.rel'.
        A zero-length string indicates that there is no backup release file so
        the primary release file (juniSystemBootReleaseFile) will be used.  On a
        set operation if there is no file found with the name specified, then an
        error is returned.  The juniSystemBootBackupConfigControl object with a
        valid value other than none(2) must be specified together with this
        object in the same set request PDU, and if the
        juniSystemBootBackupConfigControl is set to file(0) then a valid
        juniSystemBootBackupConfigFile must also be included in the set request
        PDU."
    DEFVAL    { "" }
    ::= { juniSystemGeneral 15 }

juniSystemBootBackupConfigFile  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..128))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The system-wide backup boot configuration file name, with extension
        '.cnf'.  The juniSystemBootBackupReleaseFile object, the
        juniSystemBootBackupConfigControl object set to file(0), and this object
        must be specified together in the same set request PDU.  On a set
        operation, if there is no file found with the name specified, then an
        error is returned.  If juniSystemBootBackupConfigControl is not set to
        file(0) then a get operation for this object will return a zero-length
        string."
    DEFVAL    { "" }
    ::= { juniSystemGeneral 16 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- System-wide module redundancy control objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemRedundancyRevertControl  OBJECT-TYPE
    SYNTAX      INTEGER {
                    off(0),
                    immediate(1),
                    timeOfDay(2) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Global control for reverting primary modules back from their active
        redundant spare modules:
            off       - Disable global reverts of redundant modules.
            immediate - All redundant module pairs are to revert as soon as the
                        primary module is ready to enter the online state.
            timeOfDay - All redundant module pairs are to revert at the time
                        specified by juniSystemRevertTimeOfDay, relative to
                        midnight based on the system clock time.  This object
                        must be set concurrently with juniSystemRevertTimeOfDay
                        when this value is specified.

        Note that this only applies to modules that have
        juniSystemModuleRedundancySupport set to true(1)."
    ::= { juniSystemGeneral 17 }

juniSystemRedundancyRevertTimeOfDay  OBJECT-TYPE
    SYNTAX      Integer32 (0..86399)
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The number of seconds past midnight local time on any given day at
        which time redundant slot reverts are allowed to occur.  This object
        must be set concurrently with juniSystemRevertControl { timeOfDay }."
    ::= { juniSystemGeneral 18 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Subsystem objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemSubsystemTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniSystemSubsystemEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of subsystems.  A subsystem supports a 'family' of module types;
        that is, each module type is supported by a particular software
        subsystem.  For example, the ERX channelized T1 line card (CT1-FULL) is
        supported by the 'ct1' subsystem."
    ::= { juniSystemSubsystem 1 }

juniSystemSubsystemEntry  OBJECT-TYPE
    SYNTAX      JuniSystemSubsystemEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table entry containing information pertaining to a subsystem.
        Subsystem information takes precedence over system-wide information, but
        not over individual module information."
    INDEX     { juniSystemSubsystemIndex }
    ::= { juniSystemSubsystemTable 1 }

JuniSystemSubsystemEntry  ::= SEQUENCE {
    juniSystemSubsystemIndex                 Integer32,
    juniSystemSubsystemName                  DisplayString,
    juniSystemSubsystemBootReleaseFile       DisplayString,
    juniSystemSubsystemBootBackupReleaseFile DisplayString }

juniSystemSubsystemIndex  OBJECT-TYPE
    SYNTAX      Integer32 (1..255)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Arbitrary subsystem identification number."
    ::= { juniSystemSubsystemEntry 1 }

juniSystemSubsystemName  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..128))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The name of the subsystem."
    ::= { juniSystemSubsystemEntry 2 }

juniSystemSubsystemBootReleaseFile  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..128))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The boot release file name for this subsystem, with extension '.rel'.
        If a file name is specified (a non-zero-length string), then this
        release file takes precedence over the system-wide boot release file
        (juniSystemBootReleaseFile) just for modules of the type specified by
        the subsystem name.  On a set operation, if there is no file that
        matches the name specified, then an inconsistentValue error will be
        returned.  Setting this object to a zero-length string deconfigures the
        subsystem-specific backup release file."
    DEFVAL    { "" }
    ::= { juniSystemSubsystemEntry 3 }

juniSystemSubsystemBootBackupReleaseFile  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..128))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The backup boot release file name for this subsystem, with extension
        '.rel'.  If a file name is specified (a non-zero-length string), then
        this release file takes precedence over the system-wide boot backup
        release file (juniSystemBootBackupReleaseFile) just for modules of the
        type specified by the subsystem name.  This object cannot be set unless
        the system has a backup file, which means that
        juniSystemBootBackupReleaseFile must contain a file name (a
        non-zero-length string).  On a set operation, if there is no file that
        matches the name specified, then an inconsistentValue error will be
        returned.  Setting this object to a zero-length string deconfigures the
        subsystem-specific backup release file."
    DEFVAL    { "" }
    ::= { juniSystemSubsystemEntry 4 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Module Slot objects
-- A slot represents a position in a chassis that contains one or more phisical
-- modules (printed circuit boards) and/or sub-modules that operate together as
-- a functional unit.
-- A sub-module is a functionally independent portion of a physical module.
-- One physical module may contain more than one sub-module.
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemMaxSlotNumber  OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The highest number assigned to a slot in the system.  In a particular
        hardware model, module slots have fixed numbers assigned to them, even
        though in some instances there may be no actual slots associated with a
        particular number.  In all cases there is a maximum slot number that
        will never be exceeded:
             2 for ERX-3xx models
             6 for ERX-7xx models
            13 for ERX-14xx models
            16 for E320 models

        Note that slot numbers are zero-based."
    ::= { juniSystemModule 1 }

juniSystemMaxModulesPerSlot  OBJECT-TYPE
    SYNTAX      Integer32 (1..255)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The maximum number of modules and sub-modules (different levels) that
        can be associated with a slot number in the system.  This value is
        constant for a particular hardware platform family.  The number of
        levels is 2 for a first generation E-series (ERX) platform and is 4 for
        a second generation E-series platform.

        For the first generation E-series (ERX) platform family:
            level 1 - SRP or line card module
            level 2 - I/O adapter module

        For the second generation E-series platform family:
            level 1 - Forwarding module or SRP sub-module
            level 2 - Switch fabric slice (SFS) sub-module or module
            level 3 - Bay 0 I/O adapter
            level 4 - Bay 1 I/O adapter "
    ::= { juniSystemModule 2 }

juniSystemSlotTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniSystemSlotEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of system module slot physical container configuration
        information."
    ::= { juniSystemModule 3 }

juniSystemSlotEntry  OBJECT-TYPE
    SYNTAX      JuniSystemSlotEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table entry describing the physical status of a system module slot
        container, which is designated by its slot and level positions.  There
        is an entry in this table for all index pairs from { 0, 1 } to the
        maximum for each index, { juniSystemMaxSlotNumber,
        juniSystemMaxModulesPerSlot }, even if there is no corresponding module
        slot container in the system.  A request for an index value outside this
        range will result in a 'no such' response."
    INDEX     { juniSystemSlotNumber,
                juniSystemSlotLevel }
    ::= { juniSystemSlotTable 1 }

JuniSystemSlotEntry  ::= SEQUENCE {
    juniSystemSlotNumber    Integer32,
    juniSystemSlotLevel     JuniSystemSlotLevel,
    juniSystemSlotStatus    INTEGER,
    juniSystemSlotType      JuniSystemSlotType }

juniSystemSlotNumber  OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The slot number.  The actual upper limit of valid values is
        juniSystemMaxSlotNumber.  Note that slot numbers are zero-based."
    ::= { juniSystemSlotEntry 1 }

juniSystemSlotLevel  OBJECT-TYPE
    SYNTAX      JuniSystemSlotLevel
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The relative position of a module or sub-module 'container' within a
        slot."
    ::= { juniSystemSlotEntry 2 }

juniSystemSlotStatus  OBJECT-TYPE
    SYNTAX      INTEGER {
                    unknown(0),
                    noSlotContainer(1),
                    empty(2),
                    moduleNotPresent(3),
                    modulePresent(4) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The status of the module slot container.
            unknown           - The existence of a container cannot be
                                determined
            noSlotContainer   - The physical container does not exist
            empty             - No module is present and no configuration
                                information is available for this container
            moduleNotPresent  - A module is configured but it is not currently
                                in its container
            modulePresent     - A module is inserted in the container "
    ::= { juniSystemSlotEntry 3 }

juniSystemSlotType  OBJECT-TYPE
    SYNTAX      JuniSystemSlotType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The category of modules that can be configured for the container."
    ::= { juniSystemSlotEntry 4 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Module Status objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemModuleTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniSystemModuleEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of system module and sub-module information.  In this table, a
        module refers to a physical module (board) or a sub-module.

        A physical board may contain a single module or multiple sub-modules.
        For example, an ERX line card is a single module and appears as single
        entry in this table.  An I/O adapter is a module that doesn't provide
        any operaitonal state information and it also appears as a single entry
        in this table.  A second generation E-series SRP/SFS hardware module
        contains two sub-modules, each with its own operational state
        information: a System Resource Processor (SRP) sub-module and a Switch
        Fabric Slice (SFS) sub-module, which appear as two separate entries in
        this table, one for each sub-module."
    ::= { juniSystemModule 4 }

juniSystemModuleEntry  OBJECT-TYPE
    SYNTAX      JuniSystemModuleEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table entry that provides information about a specific system module
        or sub-module in a particular module location.  There are only entries
        in this table for module locations that report a juniSystemSlotStatus of
        moduleNotPresent(3) or modulePresent(4)."
    INDEX     { juniSystemSlotNumber,
                juniSystemSlotLevel }
    ::= { juniSystemModuleTable 1 }

JuniSystemModuleEntry  ::= SEQUENCE {
    juniSystemModuleOperStatus           INTEGER,
    juniSystemModuleDisableReason        INTEGER,
    juniSystemModuleLastChange           TimeTicks,
    juniSystemModuleCurrentType          JuniSystemModuleType,
    juniSystemModuleExpectedType         JuniSystemModuleType,
    juniSystemModuleDescr                DisplayString,
    juniSystemModuleSlotSpan             Integer32,
    juniSystemModulePortCount            Integer32,
    juniSystemModuleSerialNumber         DisplayString,
    juniSystemModuleAssemblyPartNumber   DisplayString,
    juniSystemModuleAssemblyRev          DisplayString,
    juniSystemModulePhysicalIndex        PhysicalIndex,
    juniSystemModuleSoftwareSupport      TruthValue,
    juniSystemModuleRedundancySupport    TruthValue,
    juniSystemModuleLevelSpan            Integer32 }

juniSystemModuleOperStatus  OBJECT-TYPE
    SYNTAX      INTEGER {
                    unknown(0),
                    notPresent(1),
                    disabled(2),
                    hardwareError(3),
                    booting(4),
                    initializing(5),
                    online(6),
                    standby(7),
                    inactive(8),
                    notResponding(9) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The current operational status of the module (or sub-module):
            unknown       - The status of the module cannot be determined
            notPresent    - No hardware is currently present but there was a
                            module previously configured in this position (see
                            juniSystemModuleExpectedType);
                            juniSystemModuleCurrentType is unknown(0)
            disabled      - Disable for the reason specified in
                            juniSystemModuleDisableReason
            hardwareError - Not operational due to a hardware failure
            booting       - In the process of booting
            initializing  - In the process of initialing
            online        - Fully operational
            standby       - In redundant standby mode
            inactive      - In redundant inactive mode
            notResponding - Unable to communicate with the rest of the system "
    ::= { juniSystemModuleEntry 1 }

juniSystemModuleDisableReason  OBJECT-TYPE
    SYNTAX      INTEGER {
                    none(0),
                    unknown(1),
                    assessing(2),
                    admin(3),
                    typeMismatch(4),
                    fabricLimit(5),
                    imageError(6) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indicates the condition causing the module (or sub-module) to be
        disabled:
            none          - Value when the module is not disabled
            unknown       - Unknown reason for disablement
            assessing     - The module content is being assessed (transient
                            initialization state)
            admin         - The module is administratively disabled
            typeMismatch  - The current module personality conflicts with
                            configuration associated with a different (expected)
                            module personality that previously occupied the slot
            fabricLimit   - Module resource requirements exceed available fabric
                            capacity
            imageError    - Software image for the module is missing or invalid"
    ::= { juniSystemModuleEntry 2 }

juniSystemModuleLastChange  OBJECT-TYPE
    SYNTAX      TimeTicks
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of sysUpTime when the value of juniSystemModuleOperStatus
        last changed."
    ::= { juniSystemModuleEntry 3 }

juniSystemModuleCurrentType  OBJECT-TYPE
    SYNTAX      JuniSystemModuleType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The personality of this module based on the combination of modules that
        are currently inserted in the slot.  This could be different from the
        personality reported in juniSystemModuleExpectedType, in which case it
        may be necessary to set juniSystemModuleControl for the module in the
        primary level to 'flush' before the set of modules in this slot can be
        made operational."
    ::= { juniSystemModuleEntry 4 }

juniSystemModuleExpectedType  OBJECT-TYPE
    SYNTAX      JuniSystemModuleType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The personality for this module position based on the combination of
        modules that were inserted in this slot when it was last configured.
        The value of this object will be different than the value of
        juniSystemModuleCurrentType when the value of juniSystemModuleOperStatus
        is disabled(2) and the value of juniSystemModuleDisableReason is
        typeMismatch(4).  After one or more modules is removed from a slot,
        configuration information associated with the slot (its 'personality')
        may persist, inhibiting the operation of a different combination of
        modules in the slot (when new modules are inserted) until
        juniSystemModuleControl for the slot's primary module is set to
        flush(1)."
    ::= { juniSystemModuleEntry 5 }

juniSystemModuleDescr  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..63))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Textual description of the expected module in this slot."
    ::= { juniSystemModuleEntry 6 }

juniSystemModuleSlotSpan  OBJECT-TYPE
    SYNTAX      Integer32 (1..255)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of slot positions that the expected module spans.  Most
        modules are only one slot wide, but some require extra space or
        backplane resources.  These modules are identified as being in the lower
        numbered slot and spanning across the higher numbered slot(s)."
    ::= { juniSystemModuleEntry 7 }

juniSystemModulePortCount  OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of physical ports supported by the expected module type in
        this slot."
    ::= { juniSystemModuleEntry 8 }

juniSystemModuleSerialNumber  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..10))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The serial number of the expected module in this slot.  The serial
        number of the current module may be found in this module's
        entPhysicalSerialNum.  A serial number is for a hardware board, so if
        there is more than one sub-module on a board, their serial numbers will
        all be the same."
    DEFVAL    { "" }
    ::= { juniSystemModuleEntry 9 }

juniSystemModuleAssemblyPartNumber  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..10))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The part number of the expected module in this slot.  The part number
        of the current module may be found in this module's
        entPhysicalModelName.  A part number is for a hardware board, so if
        there is more than one sub-module on a board, their part numbers will
        all be the same."
    DEFVAL    { "" }
    ::= { juniSystemModuleEntry 10 }

juniSystemModuleAssemblyRev  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..3))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The revision level of the expected module in this slot.  The revision
        level of the current module may be found in this module's
        entPhysicalHardwareRev.  A revision level is for a hardware board, so if
        there is more than one sub-module on a board, their revision levels will
        all be the same."
    DEFVAL    { "" }
    ::= { juniSystemModuleEntry 11 }

juniSystemModulePhysicalIndex  OBJECT-TYPE
    SYNTAX      PhysicalIndex
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The entPhysicalIndex value assigned to the module.  The
        ENTITY-MIB.entPhysicalTable contains additional information about this
        module that can be retrieved using this index.  An entPhysicalIndex is
        for a hardware board, so if there is more than one sub-module on a
        board, their entPhysicalIndex values will all be the same."
    ::= { juniSystemModuleEntry 12 }

juniSystemModuleSoftwareSupport  OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An indicator as to whether this module or sub-module has operational
        state information that can be managed.  If the value of this object is
        true(1), then there is an entry for this module or sub-module in the
        juniSystemModuleSoftwareTable."
    ::= { juniSystemModuleEntry 13 }

juniSystemModuleRedundancySupport  OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An indicator as to whether this module or sub-module is part of a
        redundancy group.  If the value of this object is true(1), then there is
        an entry for this module or sub-module in the
        juniSystemModuleRedundancyTable."
    ::= { juniSystemModuleEntry 14 }

juniSystemModuleLevelSpan  OBJECT-TYPE
    SYNTAX      Integer32 (1..255)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of level positions that the expected module spans.  Most
        modules are only one level 'high', but some require extra space or
        backplane resources.  These modules are identified as being in the lower
        numbered level and spanning across the higher numbered level(s)."
    ::= { juniSystemModuleEntry 15 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Module Software objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemModuleSoftwareTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniSystemModuleSoftwareEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of system module software information.  This includes the
        version of the software running on the particular module, the running
        software's use of the modules resources and the modules operational
        state.

        Some module types don't contain loadable software (they execute
        'firmware') but include support for some of the objects in this table.
        For example, the E320 SFS (es2Sfs) modules only support
        juniSystemModuleAdminStatus and juniSystemModuleControl.  Appropriate
        'default' values are returned for the other objects.

        Some module types don't contain any software related information (e.g.,
        ERX I/O adapters do not) in which case their value of
        juniSystemModuleSoftwareSupport will be false and there will not be a
        corresponding entry in this table."
    ::= { juniSystemModule 5 }

juniSystemModuleSoftwareEntry  OBJECT-TYPE
    SYNTAX      JuniSystemModuleSoftwareEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table entry that provides software information about a specific
        system module in a particular slot location."
    INDEX     { juniSystemSlotNumber,
                juniSystemSlotLevel }
    ::= { juniSystemModuleSoftwareTable 1 }

JuniSystemModuleSoftwareEntry  ::= SEQUENCE {
    juniSystemModuleSoftwareVersion          DisplayString,
    juniSystemModuleCpuUtilPct               Integer32,
    juniSystemModuleMemUtilPct               Integer32,
    juniSystemModuleAdminStatus              JuniEnable,
    juniSystemModuleControl                  INTEGER,
    juniSystemModuleBootReleaseFile          DisplayString,
    juniSystemModuleBootBackupReleaseFile    DisplayString,
    juniSystemModuleCpuFiveSecUtilPct        Integer32,
    juniSystemModuleCpuOneMinAvgPct          Integer32,
    juniSystemModuleCpuFiveMinAvgPct         Integer32 }

juniSystemModuleSoftwareVersion  OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Version identification of the currently executing operational software
        on this module.  If the module is in a state where the software version
        is not known (e.g., module type mismatch), then the value of this object
        will be a zero-length string."
    ::= { juniSystemModuleSoftwareEntry 2 }

juniSystemModuleCpuUtilPct  OBJECT-TYPE
    SYNTAX      Integer32 (-1..100)
    UNITS       "percent"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Last available module CPU utilization percentage.  A value of -1
        indicates the utilization is unknown. This value is calculated over
        a 5 second period."
    ::= { juniSystemModuleSoftwareEntry 3 }

juniSystemModuleMemUtilPct  OBJECT-TYPE
    SYNTAX      Integer32 (-1..100)
    UNITS       "percent"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Percentage of module memory utilization.  A value of -1 indicates the
        utilization is unknown."
    ::= { juniSystemModuleSoftwareEntry 4 }

juniSystemModuleAdminStatus  OBJECT-TYPE
    SYNTAX      JuniEnable
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Provides administrative control to enable/disable the module.  This
        object is read-only for certain types of modules."
    ::= { juniSystemModuleSoftwareEntry 5 }

juniSystemModuleControl  OBJECT-TYPE
    SYNTAX      INTEGER {
                    noOperation(0),
                    flush(1),
                    reset(2),
                    resetBackup(3) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Administrative control of this slot:
            noOperation   - Setting this value has no effect.
            flush         - Flushes the configuration associated with a module
                            type that previously occupied this slot.  Used to
                            explicitly confirm that the slot is now empty, or
                            contains a different card type.  The module must be
                            disabled when this value is asserted.  See the
                            description for juniSystemModuleDisableReason.
            reset         - Resets the module.
            resetBackup   - Resets the module using the backup release file.

        Get operations on this variable always return noOperation.  Module types
        that do not support these operations simply ignore them."
    ::= { juniSystemModuleSoftwareEntry 6 }

juniSystemModuleBootReleaseFile  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..128))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The boot release file name for this slot, with extension '.rel'.  If a
        file name is specified (not a zero-length string), then this release
        file takes precedence over the subsystem boot release file
        (juniSystemSubsystemBootReleaseFile) and the system-wide boot release
        file (juniSystemBootReleaseFile) for just the module in this slot.

        Some module types (e.g., ERX SRP modules) don't allow this object to be
        set.  On a set operation, if there is no file that matches the name
        specified, then an inconsistentValue error will be returned.  Setting
        this object to a zero-length string deconfigures the slot-specific
        primary release file."
    DEFVAL    { "" }
    ::= { juniSystemModuleSoftwareEntry 7 }

juniSystemModuleBootBackupReleaseFile  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..128))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The backup boot release file name for this slot, with extension '.rel'.
        If a file name is specified (a non-zero-length string), then this
        release file takes precedence over the subsystem boot backup release
        file (juniSystemSubsystemBootBackupReleaseFile) and the system-wide boot
        backup release file (juniSystemBootBackupReleaseFile) for just the
        module in this slot.

        This object cannot be set unless the system has a backup file, which
        mean that juniSystemBootBackupReleaseFile must contain a file name (a
        non-zero-length string).  Some module types (e.g., ERX SRP modules)
        don't allow this object to be set.  On a set operation, if there is no
        file that matches the name specified, then an inconsistentValue error
        will be returned.  Setting this object to a zero-length string
        deconfigures the slot-specific backup release file."
    DEFVAL    { "" }
    ::= { juniSystemModuleSoftwareEntry 8 }

juniSystemModuleCpuFiveSecUtilPct  OBJECT-TYPE
    SYNTAX      Integer32 (-1..100)
    UNITS       "percent"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Percentage of average CPU utilization for the last five sec for this
         module. A value of -1 indicates the utilization is unknown."
    ::= { juniSystemModuleSoftwareEntry 9 }

juniSystemModuleCpuOneMinAvgPct  OBJECT-TYPE
    SYNTAX      Integer32 (-1..100)
    UNITS       "percent"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Percentage of average CPU utilization for the last one minute for this
         module. A value of -1 indicates the utilization is unknown."
    ::= { juniSystemModuleSoftwareEntry 10 }

juniSystemModuleCpuFiveMinAvgPct  OBJECT-TYPE
    SYNTAX      Integer32 (-1..100)
    UNITS       "percent"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Percentage of average CPU utilization for the last five minutes for 
         this module. A value of -1 indicates the utilization is unknown."
    ::= { juniSystemModuleSoftwareEntry 11 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Module Redundancy objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemModuleRedundancyTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniSystemModuleRedundancyEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of system module redundancy information.  Note that modules
        that do not support redundancy information will not appear in this
        table."
    ::= { juniSystemModule 6 }

juniSystemModuleRedundancyEntry  OBJECT-TYPE
    SYNTAX      JuniSystemModuleRedundancyEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table entry that provides information about a specific system module
        in a particular slot location."
    INDEX     { juniSystemSlotNumber,
                juniSystemSlotLevel }
    ::= { juniSystemModuleRedundancyTable 1 }

JuniSystemModuleRedundancyEntry  ::= SEQUENCE {
    juniSystemModuleRedundancyGroupId        Unsigned32,
    juniSystemModuleRedundancySpare          TruthValue,
    juniSystemModuleRedundancyAssociatedSlot Integer32,
    juniSystemModuleRedundancyLockout        JuniEnable,
    juniSystemModuleRedundancyRevertControl  INTEGER,
    juniSystemModuleRedundancyRevertTime     DateAndTime }

juniSystemModuleRedundancyGroupId  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Identifies the redundancy group as derived from hardware settings."
    ::= { juniSystemModuleRedundancyEntry 1 }

juniSystemModuleRedundancySpare  OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "True only if this module is a spare redundant module."
    ::= { juniSystemModuleRedundancyEntry 2 }

juniSystemModuleRedundancyAssociatedSlot  OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "If this module is a primary redundant module, then the module at the
        same slot level with the slot number identified by this variable is the
        spare module that serves as this module's backup.

        If this module is an active spare redundant module, then the module in
        the slot identified by this variable is the primary module for which
        this module is the spare.

        If this module is an inactive spare redundant module, then the value of
        this object is the slot number of the spare itself (the same value as
        the first index)."
    ::= { juniSystemModuleRedundancyEntry 3 }

juniSystemModuleRedundancyLockout  OBJECT-TYPE
    SYNTAX      JuniEnable
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Provides administrative control to enable/disable redundancy protection
        for the module in this slot."
    ::= { juniSystemModuleRedundancyEntry 4 }

juniSystemModuleRedundancyRevertControl  OBJECT-TYPE
    SYNTAX      INTEGER {
                    off(0),
                    immediate(1),
                    timeAndDate(2) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Per-module control for reverting a primary module back from its active
        redundant spare module:
            off           - Disable reverting to the primary module.
            immediate     - Revert as soon as this primary module is ready to
                            enter the online state.
            timeAndDate   - Revert to this primary module at time specified by
                            juniSystemModuleRedundancyRevertTime, provided it is
                            in the inactive state.

        This control only applies to primary modules; spare modules can only be
        set to off(0)."
    ::= { juniSystemModuleRedundancyEntry 5 }

juniSystemModuleRedundancyRevertTime  OBJECT-TYPE
    SYNTAX      DateAndTime (SIZE(8))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The date and time associated with the timeAndDate (delayed) revert
        operation.  Only the local format for DateAndTime is supported.  On a
        set operation, if the time specified is prior to the current time, then
        an inconsistent value error is returned.This object must be set concurrently 
		with juniSystemModuleRedundancyRevertControl { timeAndDate(2) }."
    ::= { juniSystemModuleRedundancyEntry 6 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- I/O Port objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemPortTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniSystemPortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of system physical I/O ports.  The information in this table
        reflects the ports for the expected module type in each slot; in event
        of a module mismatch, this table permits navigation of the existing
        configuration of the expected module type."
    ::= { juniSystemPort 1 }

juniSystemPortEntry  OBJECT-TYPE
    SYNTAX      JuniSystemPortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table entry describing a physical port of the system."
    INDEX     { juniSystemSlotNumber,
                juniSystemSlotLevel,
                juniSystemPortNumber }
    ::= { juniSystemPortTable 1 }

JuniSystemPortEntry  ::= SEQUENCE {
    juniSystemPortNumber         Integer32,
    juniSystemPortIfIndex        InterfaceIndexOrZero,
    juniSystemPortPhysicalIndex  PhysicalIndex }

juniSystemPortNumber  OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Port number of this physical port, relative to the slot in which it
        resides.  Each physical port is uniquely distinguished by its slot
        number, slot level and port number.  Port numbers are zero-based."
    ::= { juniSystemPortEntry 1 }

juniSystemPortIfIndex  OBJECT-TYPE
    SYNTAX      InterfaceIndexOrZero
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The ifIndex of the Interfaces MIB ifTable entry corresponding to this
        physical port; if zero, the ifIndex is unknown or does not exist."
    ::= { juniSystemPortEntry 2 }

juniSystemPortPhysicalIndex  OBJECT-TYPE
    SYNTAX      PhysicalIndex
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The entPhysicalIndex value assigned to this port.  This index may be
        use to retrieve other information about the port, such as description
        and type, from the ENTITY-MIB.entPhysicalTable."
    ::= { juniSystemPortEntry 3 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Timing objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemAdminTimingSource  OBJECT-TYPE
    SYNTAX      JuniSystemTimingSelector
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The administrative timing source for the system.  This variable is used
        to select the desired timing source to be either primary, secondary or
        tertiary.  Setting this variable will cause the system to change to the
        specified timing source, provided it is currently available.  Setting
        this value to error(4) is not allowed.

        The system periodically monitors the status of the three timing sources.
        If the systems current timing source fails, the system will
        automatically downgrade to the next timing source.  If the system is
        configured to automatically upgrade (juniSystemTimingAutoUpgrade is set
        to enable(1)) the system will switch back to the timing source indicated
        by this variable when it becomes available.

        A timing source failure can be detected by comparing the operational and
        administrative timing sources.  If they are not equal, the system has
        swapped timing sources because the administratively set timing source is
        in the error state."
    ::= { juniSystemTiming 1 }

juniSystemOperTimingSource  OBJECT-TYPE
    SYNTAX      JuniSystemTimingSelector
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The operational timing source for the system.  The system periodically
        monitors the status of three timing sources, primary, secondary and
        tertiary.  If the systems current timing source fails, the system will
        automatically downgrade to the next timing source.  If the system is
        configured to automatically upgrade (juniSystemTimingAutoUpgrade is set
        to enable(1)) the system will switch back to the higher timing source
        when it becomes available."
    ::= { juniSystemTiming 2 }

juniSystemTimingAutoUpgrade  OBJECT-TYPE
    SYNTAX      JuniEnable
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object controls the automatic timing selector upgrade.  Setting
        this object to disable(0) will prevent automatic upgrade to the next
        highest timing selector.  Setting this object to enable(1) will enable
        the automatic upgrade of timing selectors."
    DEFVAL    { enable }
    ::= { juniSystemTiming 3 }

juniSystemTimingSelectorTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniSystemTimingSelectorEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of system timing selectors.  This table only contains entries for
        the primary, secondary and tertiary selecors."
    ::= { juniSystemTiming 4 }

juniSystemTimingSelectorEntry  OBJECT-TYPE
    SYNTAX      JuniSystemTimingSelectorEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table entry describing a system timing selector."
    INDEX     { juniSystemTimingSelectorIndex }
    ::= { juniSystemTimingSelectorTable 1 }

JuniSystemTimingSelectorEntry  ::= SEQUENCE {
    juniSystemTimingSelectorIndex    JuniSystemTimingSelector,
    juniSystemTimingSourceType       INTEGER,
    juniSystemTimingSourceIfIndex    InterfaceIndexOrZero,
    juniSystemTimingSourceLine       INTEGER,
    juniSystemTimingWorkingStatus    INTEGER,
    juniSystemTimingProtectedStatus  INTEGER }

juniSystemTimingSelectorIndex  OBJECT-TYPE
    SYNTAX      JuniSystemTimingSelector
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The system timing selector index associated with this entry.  There are
        valid indexes for selector types primary(1), secondary(2), tertiary(3)."
    ::= { juniSystemTimingSelectorEntry 1 }

juniSystemTimingSourceType  OBJECT-TYPE
    SYNTAX      INTEGER {
                    timingInterfaceIfIndex(1),
                    timingInternal(2),
                    timingLine(3) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The system timing source type for this entry.  This object must be set
        to timingInterfaceIfIndex(1) when setting the
        juniSystemTimingSourceIfIndex object or timingLine(3) when setting the
        juniSystemTimingSourceLine object.  Also, if the value of this object is
        set to timingInternal(2), no other objects should be set, otherwise the
        agent will return an error."
    ::= { juniSystemTimingSelectorEntry 2 }

juniSystemTimingSourceIfIndex  OBJECT-TYPE
    SYNTAX      InterfaceIndexOrZero
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The ifIndex of the interface selected as the system timing source.  If
        the juniSystemTimingSourceType object is not timingInterfaceIfIndex(1),
        then reading this object will return a zero value.  The agent will not
        accept a set to this object unless the juniSystemTimingSourceType object
        is set to timingInterfaceIfIndex(1)."
    DEFVAL    { 0 }
    ::= { juniSystemTimingSelectorEntry 3 }

juniSystemTimingSourceLine  OBJECT-TYPE
    SYNTAX      INTEGER {
                    timingSourceLineUndefined(0),
                    timingSourceLineE1PortA(1),
                    timingSourceLineE1PortB(2),
                    timingSourceLineT1PortA(3),
                    timingSourceLineT1PortB(4) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The line type timing source for this entry.  If the
        juniSystemTimingSourceType object is not timingLine(3), then reading
        this object will return timingSourceLineUndefined(0).  The agent will
        not accept a set to this object unless the juniSystemTimingSourceType
        object is set to timingLine(3).  Attempting to set this object to
        timingSourceLineUndefined(0) will always return an inconsistantValue
        error.  Attempting to set this object to a value that is not supported
        on the type of system running the agent will result in an
        inconsistantValue error."
    DEFVAL    { timingSourceLineUndefined }
    ::= { juniSystemTimingSelectorEntry 4 }

juniSystemTimingWorkingStatus  OBJECT-TYPE
    SYNTAX      INTEGER {
                    timingStatusOk(1),
                    timingStatusError(2),
                    timingStatusUnknown(3) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The status associated with the working (normal) source of this system
        timing working selector."
    ::= { juniSystemTimingSelectorEntry 5 }

juniSystemTimingProtectedStatus  OBJECT-TYPE
    SYNTAX      INTEGER {
                    timingStatusOk(1),
                    timingStatusError(2),
                    timingStatusUnknown(3),
                    sourceNotProtected(4) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The status associated with the protected (backup) source of this system
        timing selector.  If the system doesn't support protected timing
        sources, then sourceNotProtected(4) will be returned."
    ::= { juniSystemTimingSelectorEntry 6 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Fabric objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemFabricSpeed  OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "gigabits per second"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The speed of switching fabric, in gigabits per second."
    ::= { juniSystemFabric 1 }

juniSystemFabricRev  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..10))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The fabric revision number.  If unknown, a zero-length string is
        reported."
    ::= { juniSystemFabric 2 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Non-Volatile Storage status objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemNvsCount  OBJECT-TYPE
    SYNTAX      Integer32 (1..255)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of non-volatile storage (NVS) 'flash' cards in the system."
    ::= { juniSystemNvs 1 }

juniSystemNvsTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniSystemNvsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of NVS status information."
    ::= { juniSystemNvs 2 }

juniSystemNvsEntry  OBJECT-TYPE
    SYNTAX      JuniSystemNvsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table entry that provides the status information for a NVS flash
        card."
    INDEX     { juniSystemNvsIndex }
    ::= { juniSystemNvsTable 1 }

JuniSystemNvsEntry  ::= SEQUENCE {
    juniSystemNvsIndex           Integer32,
    juniSystemNvsStatus          INTEGER,
    juniSystemNvsCapacity        Unsigned32,
    juniSystemNvsUtilPct         Integer32,
    juniSystemNvsPhysicalIndex   PhysicalIndex }

juniSystemNvsIndex  OBJECT-TYPE
    SYNTAX      Integer32 (1..255)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index number of the NVS flash card.  There is an entry in this
        table for all values of this index in the range of 1 to the value of
        juniSystemNvsCount."
    ::= { juniSystemNvsEntry 1 }

juniSystemNvsStatus  OBJECT-TYPE
    SYNTAX      INTEGER {
                    notPresent(0),
                    writeProtected(1),
                    volumeError(2),
                    nearCapacity(3),
                    ok(4),
                    noConfigSpace(5) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The status of non-volatile storage (NVS):
            notPresent        - The SRP or the flash card is not accessible.
            writeProtected    - NVS is write-protected.
            volumeError       - Status poll of NVS failed.
            nearCapacity      - Utilization exceeds 85% of NVS capacity.
            ok                - NVS is fully operational with ample capacity.
            noConfigSpace     - Utilization exceeds the ability to save the
                                running configuration."
    ::= { juniSystemNvsEntry 2 }

juniSystemNvsCapacity  OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "megabytes"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The capacity of NVS storage in megabytes."
    ::= { juniSystemNvsEntry 3 }

juniSystemNvsUtilPct  OBJECT-TYPE
    SYNTAX      Integer32 (-1..100)
    UNITS       "percent"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The percentage of NVS storage used.  A value of -1 indicates NVS
        utilization is unknown."
    ::= { juniSystemNvsEntry 4 }

juniSystemNvsPhysicalIndex  OBJECT-TYPE
    SYNTAX      PhysicalIndex
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The entPhysicalIndex value assigned to this NVS flash card.  This index
        may be use to retrieve other information about the NVS flash card, such
        as description and type, from the ENTITY-MIB.entPhysicalTable."
    ::= { juniSystemNvsEntry 5 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Power element objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemPowerCount  OBJECT-TYPE
    SYNTAX      Integer32 (1..255)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of power elements in the system."
    ::= { juniSystemPower 1 }

juniSystemPowerTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniSystemPowerEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of status variables for the system power elements."
    ::= { juniSystemPower 2 }

juniSystemPowerEntry  OBJECT-TYPE
    SYNTAX      JuniSystemPowerEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table entry describing status of a system power element."
    INDEX     { juniSystemPowerIndex }
    ::= { juniSystemPowerTable 1 }

JuniSystemPowerEntry  ::= SEQUENCE {
    juniSystemPowerIndex         Integer32,
    juniSystemPowerStatus        INTEGER,
    juniSystemPowerPhysicalIndex PhysicalIndex }

juniSystemPowerIndex  OBJECT-TYPE
    SYNTAX      Integer32 (1..255)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index number of the power element.  There is an entry in this table
        for all values of this index in the range of 1 to the value of
        juniSystemPowerCount."
    ::= { juniSystemPowerEntry 1 }

juniSystemPowerStatus  OBJECT-TYPE
    SYNTAX      INTEGER {
                    notPresent(0),
                    inactive(1),
                    good(2),
                    failed(3),
                    sensorFailed(4),
                    unknown(5) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The status of the power element:
            notPresent    - The power element is removed from the chassis.
            inactive      - No power is available from this element.
            good          - Power is available from this element.
            failed        - The power element is not working.
            sensorFailed  - The power element sensor has failed.
            unknown       - The status of the power element is not availiable."
    ::= { juniSystemPowerEntry 2 }

juniSystemPowerPhysicalIndex  OBJECT-TYPE
    SYNTAX      PhysicalIndex
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The entPhysicalIndex value assigned to this power element.  This index
        may be use to retrieve other information about the power element, such
        as description and type, from the ENTITY-MIB.entPhysicalTable."
    ::= { juniSystemPowerEntry 3 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Temperature control (fan subsystem) objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemFanCount  OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The maximum number of fan subsystems that may be present in the system.
        This is a fixed number for each product type."
    ::= { juniSystemTemperature 1 }

juniSystemFanTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniSystemFanEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of status of the system's fan subsystems."
    ::= { juniSystemTemperature 2 }

juniSystemFanEntry  OBJECT-TYPE
    SYNTAX      JuniSystemFanEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table entry describing status of a fan subsystem."
    INDEX     { juniSystemFanIndex }
    ::= { juniSystemFanTable 1 }

JuniSystemFanEntry  ::= SEQUENCE {
    juniSystemFanIndex           Integer32,
    juniSystemFanStatus          INTEGER,
    juniSystemFanPhysicalIndex   PhysicalIndex }

juniSystemFanIndex  OBJECT-TYPE
    SYNTAX      Integer32 (1..255)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index number of the fan subsystem.  This is a number in the range
        of 1 to the value of juniSystemFanCount."
    ::= { juniSystemFanEntry 1 }

juniSystemFanStatus  OBJECT-TYPE
    SYNTAX      INTEGER {
                    failed(0),
                    ok(1),
                    warning(2) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Status of fan subsystem.
            failed    - The fan subsystem has a critical failure, or has been
                        removed, and is now non-operational.
            ok        - All components are operational.
            warning   - The fan subsystem has a non-critical failure."
    ::= { juniSystemFanEntry 2 }

juniSystemFanPhysicalIndex  OBJECT-TYPE
    SYNTAX      PhysicalIndex
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The entPhysicalIndex value assigned to this fan subsystem.  This index
        may be use to retrieve other information about the fan subsystem, such
        as description and type, from the ENTITY-MIB.entPhysicalTable."
    ::= { juniSystemFanEntry 3 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Temperature sensor objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemTempCount  OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The maximum number of possible temperature sensors in the system."
    ::= { juniSystemTemperature 3 }

juniSystemTempTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniSystemTempEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of status of the system's temperature sensors."
    ::= { juniSystemTemperature 4 }

juniSystemTempEntry  OBJECT-TYPE
    SYNTAX      JuniSystemTempEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table entry describing status of a temperature sensor.  Sensors are
        located throughout the system.  The ENTITY_MIB.entPhysicalTable provides
        detailed information about the location of each sensor.  The index for a
        table entry is fixed based on a product-specific algorithm that uses the
        maximum number of sensors that may be on any module type associated with
        each of the available slots.  This means that entries for sensors
        associated with empty slots and the 'extra' sensors on modules that have
        less than the maximum number of sensors for the slot type will have a
        notPresent status."
    INDEX     { juniSystemTempIndex }
    ::= { juniSystemTempTable 1 }

JuniSystemTempEntry  ::= SEQUENCE {
    juniSystemTempIndex          Integer32,
    juniSystemTempStatus         INTEGER,
    juniSystemTempValue          Integer32,
    juniSystemTempPhysicalIndex  Integer32 }

juniSystemTempIndex  OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An arbitrary number to uniquely identify the temperature sensor."
    ::= { juniSystemTempEntry 1 }

juniSystemTempStatus  OBJECT-TYPE
    SYNTAX      INTEGER {
                    unknown(0),
                    failed(1),
                    tooLow(2),
                    nominal(3),
                    tooHigh(4),
                    tooLowWarning(5),
                    tooHighWarning(6) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The status of a temperature sensor:
            unknown           - sensor is not present or is not accessible
            failed            - sensor is broken
            tooLow            - temperature is below nominal range
            nominal           - temperature is within nominal range
            tooHigh           - temperature is above nominal range
            tooLowWarning     - temperature is near the nominal lower limit
            tooHighWarning    - temperature is near the nominal upper limit "
    ::= { juniSystemTempEntry 2 }

juniSystemTempValue  OBJECT-TYPE
    SYNTAX      Integer32
    UNITS       "degrees Celsius"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The temperature measured by this sensor in degrees Celsius.  This
        measurement is valid only if the value of the corresponding
        juniSystemTempStatus is tooLow, nominal or tooHigh."
    ::= { juniSystemTempEntry 3 }

juniSystemTempPhysicalIndex  OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The entPhysicalIndex value assigned to this temperature sensor.  If the
        temperature sensor is not present this object will return a value of 0.
        For non-zero values this index may be used to retrieve other information
        about the temperature sensor from the ENTITY-MIB.entPhysicalTable, such
        as description and location."
    ::= { juniSystemTempEntry 4 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Thermal protection objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemTempProtectionStatus  OBJECT-TYPE
    SYNTAX      INTEGER {
                    off(0),
                    monitoring(1),
                    inHoldOff(2),
                    activatedHoldOffExpired(3),
                    activatedTempTooHigh(4) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Thermal Protection status:
            off                       - No thermal protection.
            monitoring                - Monitoring.
            inHoldOff                 - Hold off time has begun.
            activatedHoldOffExpired   - Hold off time has expired; the system
                                        is in thermal protection mode.
            activatedTempTooHigh      - The temperature is too high, the system
                                        is in thermal protection mode."
    ::= { juniSystemTemperature 5 }

juniSystemTempProtectionHoldOffTime  OBJECT-TYPE
    SYNTAX      Integer32 (0..1200)
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time, in seconds, before the system enters Thermal Protection mode
        after a critical thermal failure is detected."
    DEFVAL    { 150 }
    ::= { juniSystemTemperature 6 }

juniSystemTempProtectionHoldOffTimeRemaining  OBJECT-TYPE
    SYNTAX      Integer32 (0..1200)
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time remaining, in seconds, before the system enters Thermal
        Protection mode while the ThermalProtectionStatus is set to inHoldOff.
        The value decrements every second until it reaches zero, and the status
        changes to activatedHoldOffExpired.  When ThermalProtectionStatus is not
        inHoldOff or activatedHoldOffExpired, the value is set to the hold off
        time."
    DEFVAL    { 150 }
    ::= { juniSystemTemperature 7 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Resource utilization objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
--
-- Resource utilization status table
--
juniSystemUtilizationTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniSystemUtilizationEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of status of the utilization of system resources.  It is an
        implementation option as to which resources (if any) are supported in
        this table.  It is also an implementation option as to whether the
        threshold objects are supported for a particular instance."
    ::= { juniSystemUtilization 1 }

juniSystemUtilizationEntry  OBJECT-TYPE
    SYNTAX      JuniSystemUtilizationEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table entry describing the status of the utilization of a system
        resource."
    INDEX     { juniSystemUtilizationResourceType,
                juniSystemUtilizationResourceSubType,
                juniSystemUtilizationLocationType,
                juniSystemUtilizationLocation }
    ::= { juniSystemUtilizationTable 1 }

JuniSystemUtilizationEntry  ::= SEQUENCE {
    juniSystemUtilizationResourceType       INTEGER,
    juniSystemUtilizationResourceSubType    Integer32,
    juniSystemUtilizationLocationType       JuniSystemLocationType,
    juniSystemUtilizationLocation           JuniSystemLocation,
    juniSystemUtilizationMaxCapacity        Gauge32,
    juniSystemUtilizationCurrentValue       Gauge32,
    juniSystemUtilizationThresholdRising    Gauge32,
    juniSystemUtilizationThresholdFalling   Gauge32,
    juniSystemUtilizationHoldDownTime       Gauge32 }

juniSystemUtilizationResourceType  OBJECT-TYPE
    SYNTAX      INTEGER {
                    interface(1),
                    memory(2) }
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This index identifies a type of enumerated value that is used for the
        juniSystemUtilizationResourceSubType.  See the DESCRIPTION for
        juniSystemUtilizationResourceSubType for the mapping of Type to SubType
        enumeration and the corresponding units of measure used for each type of
        resource."
    ::= { juniSystemUtilizationEntry 1 }

juniSystemUtilizationResourceSubType  OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This index uses an enumerated value that is different for each value of
        juniSystemUtilizationResourceType.  The following table shows the
        mapping of Type to SubType enumeration and the corresponding units of
        measure used for each type of resource.

        Type        SubType                         Units
        -----------+-------------------------------+----------------------------
        interface   Juniper-UNI-IF-MIB.juniIfType   number of interfaces
        memory      SNMPv2-TC.StorageType           HOST-RESOURCES-MIB.KBytes "
    ::= { juniSystemUtilizationEntry 2 }

juniSystemUtilizationLocationType  OBJECT-TYPE
    SYNTAX      JuniSystemLocationType
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This index element identifies the format of the location information so
        that the juniSystemUtilizationLocation index element can be properly
        interpreted."
    ::= { juniSystemUtilizationEntry 3 }

juniSystemUtilizationLocation  OBJECT-TYPE
    SYNTAX      JuniSystemLocation
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This index is used to specify the resource instance based on its
        location.  Its value is interpreted based on the location type
        identified by the juniSystemUtilizationLocationType index element."
    ::= { juniSystemUtilizationEntry 4 }

juniSystemUtilizationMaxCapacity  OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The maximum number of units of the resource the system can support.

        See the DESCRIPTION of juniSystemUtilizationResourceSubType for what
        constitutes a unit of value for this object.

        Note that for some resources this value may not always be achievable due
        to other resource constraints."
    ::= { juniSystemUtilizationEntry 5 }

juniSystemUtilizationCurrentValue  OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The current number of units of the resource in the system.

        See the DESCRIPTION for juniSystemUtilizationResourceSubType for what
        constitutes a unit of value for this object.

        Note that some resource types may have instances that do not consume any
        limited resources and therefore are not included in this count (e.g. IP
        loopback interfaces do not consume routing resources and therefore don't
        have a capacity limit, whereas 'external' IP interfaces do)."
    ::= { juniSystemUtilizationEntry 6 }

juniSystemUtilizationThresholdRising  OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The threshold value (risingVal), which, in conjunction with
        juniSystemUtilizationHoldDownTime (holdTime) and
        juniSystemUtilizationThresholdFalling (fallingVal), is used to decide
        when to trigger an event indicating that the resource utilization,
        juniSystemUtilizationCurrentValue (currentVal), is approaching or has
        reached its maximum capacity, juniSystemUtilizationMaxCapacity (maxVal).

        See the DESCRIPTION for juniSystemUtilizationResourceSubType for what
        constitutes a unit of value for this object.

        The value of fallingVal must be less than the value of this object.

        This object provides one element in the formula used to determine when
        to send a utilization notification.  If the currentVal rises to equal
        the risingVal and no other utilization event (either rising or falling)
        has been triggered within the holdTime, or if the holdTime for a falling
        threshold notification expires and the currentVal is at or above the
        risingVal, then and only then is a rising threshold utilization
        notification sent.

        The following pseudo-code states the algorithm more precisely.

        When the resource is created or initialized ( currentVal == 0 ):
            lastTrapType = none;
            lastTrapTime = 0;

        When currentVal increments (increases):
            if ( currentVal == risingVal &&
                 lastTrapTime + holdTime <= currentTime ) {
                triggerUtilizationTrapRising();
                lastTrapType = rising;
                lastTrapTime = currentTime; }

        When currentVal decrements (decreases):
            if ( currentVal == fallingVal &&
                 lastTrapTime + holdTime <= currentTime ) {
                triggerUtilizationTrapFalling();
                lastTrapType = falling;
                lastTrapTime = currentTime; }

        When the rising threshold value is modified:
            if ( currentVal < oldRisingVal &&
                 currentVal >= newRisingVal &&
                 lastTrapTime + holdTime <= currentTime )
                triggerUtilizationTrapRising();
                lastTrapType = rising;
                lastTrapTime = currentTime; }

        When the falling threshold value is modified:
            if ( currentVal > oldFallingVal &&
                 currentVal <= newFallingVal &&
                 lastTrapTime + holdTime <= currentTime )
                triggerUtilizationTrapFalling();
                lastTrapType = falling;
                lastTrapTime = currentTime; }

        When a hold-down time expires (lastTrapTime + holdTime == currentTime):
            switch ( lastTrapType ) {
                case rising:
                    if ( currentVal <= fallingVal ) {
                        triggerUtilizationTrapFalling();
                        lastTrapType = falling;
                        lastTrapTime = currentTime; }
                    else {
                        lastTrapType = none; }
                    break;
                case falling:
                    if ( currentVal >= risingVal ) {
                        triggerUtilizationTrapRising();
                        lastTrapType = rising;
                        lastTrapTime = currentTime; }
                    else {
                        lastTrapType = none; }
                    break; } "
    ::= { juniSystemUtilizationEntry 7 }

juniSystemUtilizationThresholdFalling  OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The threshold value (fallingVal), which, in conjunction with
        juniSystemUtilizationHoldDownTime (holdTime) and
        juniSystemUtilizationThresholdRising (risingVal), is used to decide when
        to trigger an event indicating that the resource utilization,
        juniSystemUtilizationCurrentValue (currentVal), has fallen to or below
        this level after having exceeded this value.

        See the DESCRIPTION for juniSystemUtilizationResourceSubType for what
        constitutes a unit of value for this object.

        The value of this object  must be less than the value of risingVal.

        This object provides one element in the formula used to determine when
        to send a utilization notification.  If the currentVal falls to equal
        the fallingVal and no other utilization event (either rising or falling)
        has been triggered within the holdTime, or if the holdTime for a rising
        threshold notification expires and the currentVal is at or below the
        fallingVal, then and only then is a falling threshold utilization
        notification sent.

        The pseudo-code in the juniSystemUtilizationThresholdRising DESCRIPTION
        states the algorithm more precisely."
    ::= { juniSystemUtilizationEntry 8 }

juniSystemUtilizationHoldDownTime  OBJECT-TYPE
    SYNTAX      Gauge32
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The hold-down time (holdTime) used in conjunction with
        juniSystemUtilizationThresholdRising (risingVal) and
        juniSystemUtilizationThresholdFalling (fallingVal) to decide when to
        trigger an event indicating that the resource utilization,
        juniSystemUtilizationCurrentValue (currentVal), has reached or surpassed
        one of the thresholds.

        This object provides one element in the formula used to determine when
        to send a utilization notification.  If the resource utilization
        increases to the rising threshold value but a prior rising or falling
        utilization event has been triggered within this hold-down time then no
        rising threshold utilization notification may be sent at that time.  If
        the resource utilization decreases to the falling threshold value but a
        prior rising or falling utilization event has been triggered within this
        hold-down time then no falling threshold utilization notification may be
        sent at that time.  However, if the end of a hold-down period for a
        rising threshold utilization notification is reached and the current
        value is at or below the falling threshold value, then a falling
        threshold notification is sent and the hold-down timer is restarted.
        Likewise, if the end of a hold-down period for a falling threshold
        utilization notification is reached and the current value is at or above
        the rising threshold value, then a rising threshold notification is sent
        and the hold-down timer is restarted.

        The pseudo-code in the juniSystemUtilizationThresholdRising DESCRIPTION
        states the algorithm more precisely."
    ::= { juniSystemUtilizationEntry 9 }

-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Task profiling (process cpu utilization) objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemCpuUtilizationTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniSystemCpuUtilizationEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of status of the cpu utilization by various tasks."
    ::= { juniSystemUtilization 2 }

juniSystemCpuUtilizationEntry  OBJECT-TYPE
    SYNTAX      JuniSystemCpuUtilizationEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table entry describing cpu utilization of a particular task."
    INDEX { juniSystemCpuUtilizationTimeMark,
            juniSystemCpuUtilizationTaskName }
    ::= { juniSystemCpuUtilizationTable 1 }

JuniSystemCpuUtilizationEntry ::= SEQUENCE {
    juniSystemCpuUtilizationTimeMark                  JuniTimeFilter,
    juniSystemCpuUtilizationTaskName                  JuniSystemTaskName,
    juniSystemCpuUtilizationInvoked                   Integer32,
    juniSystemCpuUtilizationInvokationPerSec          Integer32,
    juniSystemCpuUtilizationTotalRunningTime          Integer32,
    juniSystemCpuUtilizationPercentageRunningTime     Integer32,    
    juniSystemCpuUtilizationAverageTimePerInvokation  Integer32,
    juniSystemCpuUtilizationFiveSecondUtilization     Integer32,    
    juniSystemCpuUtilizationOneMinuteUtilization      Integer32,
    juniSystemCpuUtilizationFiveMinuteUtilization     Integer32,
    juniSystemCpuUtilizationNumberOfInstances         Integer32 }

juniSystemCpuUtilizationTimeMark  OBJECT-TYPE
    SYNTAX      JuniTimeFilter
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A TimeFilter for this task profile entry.  Allows GetNext and GetBulk
        to find task profile rows which have changed since a specified
        value of sysUptime."
    REFERENCE
        "Refer to RFC 2021 for the definition of the TimeFilter, its usage and 
        implementation notes."
    ::= { juniSystemCpuUtilizationEntry 1 }

juniSystemCpuUtilizationTaskName  OBJECT-TYPE
    SYNTAX      JuniSystemTaskName
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Task name associated with this task profile entry."
    ::= { juniSystemCpuUtilizationEntry 2 }

juniSystemCpuUtilizationInvoked  OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of times task associated with this task profile 
        entry being invoked."
    ::= { juniSystemCpuUtilizationEntry 3 }

juniSystemCpuUtilizationInvokationPerSec  OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Rate of invokation for the task associated with this task 
        profile entry."
    ::= { juniSystemCpuUtilizationEntry 4 }

juniSystemCpuUtilizationTotalRunningTime  OBJECT-TYPE
    SYNTAX      Integer32
    UNITS       "milli Seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total running time for the task associated with this task 
        profile entry."
    ::= { juniSystemCpuUtilizationEntry 5 }

juniSystemCpuUtilizationPercentageRunningTime  OBJECT-TYPE
    SYNTAX      Integer32 (0..100)
    UNITS       "percent"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Percentage running time for the task associated with this task 
        profile entry."
    ::= { juniSystemCpuUtilizationEntry 6 }

juniSystemCpuUtilizationAverageTimePerInvokation  OBJECT-TYPE
    SYNTAX      Integer32
    UNITS       "micro Seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Average running time per invokation for the task associated  
        with this task profile entry."
    ::= { juniSystemCpuUtilizationEntry 7 }

juniSystemCpuUtilizationFiveSecondUtilization  OBJECT-TYPE
    SYNTAX      Integer32 (0..100)
    UNITS       "percent"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Utilization in terms of percentage during the five seconds measurement 
        interval for the task associated with this task profile entry."
    ::= { juniSystemCpuUtilizationEntry 8 }

juniSystemCpuUtilizationOneMinuteUtilization  OBJECT-TYPE
    SYNTAX      Integer32 (0..100)
    UNITS       "percent"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Utilization in terms of percentage during the one minute measurement 
        interval for the task associated with this task profile entry."
    ::= { juniSystemCpuUtilizationEntry 9 }

juniSystemCpuUtilizationFiveMinuteUtilization  OBJECT-TYPE
    SYNTAX      Integer32 (0..100)
    UNITS       "percent"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Utilization in terms of percentage during the five minutes measurement 
        interval for the task associated with this task profile entry."
    ::= { juniSystemCpuUtilizationEntry 10 }

juniSystemCpuUtilizationNumberOfInstances  OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of instances consolidated for CPU utilization calculation in this 
        task profile entry."
    ::= { juniSystemCpuUtilizationEntry 11 }

-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- ISSU objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemIssuState   OBJECT-TYPE 
    SYNTAX      INTEGER {
                    idle(1),
                    initializing(2),
                    initialized(3),
                    upgrading(4),
                    stopping(5) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The state of the system with respect to ISSU upgrade:
            idle         - ISSU is currently idle
            initializing - ISSU initialization is in-progress 
            initialized  - ISSU has successfully initialized
            upgrading    - ISSU is currently upgrading to the new armed release
            stopping     - ISSU is currently in the process of stopping

        This object is supported on the second generation E-series
        platform family (E320 & E120) in JUNOSe 9.0 and subsequent system
        releases. This object is also supported on ERX-1440 in JUNOSe 9.2
        and subsequent system releases."
    ::= { juniSystemIssu  1 }

juniSystemIssuRunningReleaseFile  OBJECT-TYPE 
    SYNTAX          DisplayString (SIZE(0..128)) 
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "The currently running release file name, with extension '.rel'.
        The system was booted last time with this release file.

        This object is supported on the second generation E-series
        platform family (E320 & E120) in JUNOSe 9.0 and subsequent system
        releases. This object is also supported on ERX-1440 in JUNOSe 9.2
        and subsequent system releases."
    ::= { juniSystemIssu  2 }

juniSystemIssuArmedReleaseFile    OBJECT-TYPE 
    SYNTAX          DisplayString (SIZE(0..128)) 
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "The currently armed release file name, with extension '.rel'.
        The system will be booted with this release file, after ISSU (if
        it is not aborted).

        This object is supported on the second generation E-series
        platform family (E320 & E120) in JUNOSe 9.0 and subsequent system
        releases. This object is also supported on ERX-1440 in JUNOSe 9.2
        and subsequent system releases."
    ::= { juniSystemIssu 3 }

juniSystemIssuStatus  OBJECT-TYPE 
    SYNTAX      INTEGER {
                    ok(1),
                    warning(2),
                    error(3) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The status of the system with respect to ISSU upgrade.
            ok           - no error or warning found
            warning      - at least one upgrade warning found, upgrade is possible
            error        - at least one upgrade error found, upgrade is not possible

        This object is supported on the second generation E-series
        platform family (E320 & E120) in JUNOSe 9.0 and subsequent system
        releases. This object is also supported on ERX-1440 in JUNOSe 9.2
        and subsequent system releases."
    ::= { juniSystemIssu  4 }

-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- ISSU upgrade Criteria
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemIssuCriteriaTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF JuniSystemIssuCriteriaEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "A Table of criteria for an ISSU initialization.
        
        This table will be empty for unsupported platforms. These objects
        are supported on the second generation E-series platform
        family (E320 & E120) in JUNOSe 9.0 and subsequent system releases.
        This object is also supported on ERX-1440 in JUNOSe 9.2 and
        subsequent system releases."
    ::= { juniSystemIssu 5 }

juniSystemIssuCriteriaEntry  OBJECT-TYPE
    SYNTAX          JuniSystemIssuCriteriaEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "A table entry describing the criteria for an ISSU initialization."
    INDEX           { juniSystemIssuCriteriaIndex }
    ::= { juniSystemIssuCriteriaTable 1 }

    JuniSystemIssuCriteriaEntry ::= SEQUENCE {
        juniSystemIssuCriteriaIndex                   Integer32,
        juniSystemIssuCriteriaDescription             DisplayString,
        juniSystemIssuCriteriaStatus                  INTEGER }

juniSystemIssuCriteriaIndex   OBJECT-TYPE
    SYNTAX      Integer32 (1..255)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index associated with an entry of the system ISSU Criteria Table."
    ::= { juniSystemIssuCriteriaEntry 1 }

juniSystemIssuCriteriaDescription   OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..255))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "To initialize ISSU, few criteria need to be met. If these criteria
        were not met, ISSU cannot be initialized. This object provides the
        criteria details."
    ::= { juniSystemIssuCriteriaEntry 2 }

juniSystemIssuCriteriaStatus    OBJECT-TYPE
    SYNTAX      INTEGER {
                    yes(1),
                    no(2),
                    conditional(3)}
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "To initialize ISSU, few criteria need to be met. If these criteria
        were not met, ISSU cannot be initialized. This object indicates
        whether a criteria has met. It will be conditional when that the
        user can choose to accept the consequences of proceeding with ISSU
        with non-ideal operating conditions."
    ::= { juniSystemIssuCriteriaEntry 3 }

-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Notification control objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemMemUtilTrapEnable  OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Controls the sending of primary system processor memory utilization
        events.  Setting the value of this object to true(1) will cause system
        memory utilization event notifications, if they occur, to be sent to the
        management entity on this system.  Setting the value of this object to
        false(2) will disable memory utilization event notifications."
    DEFVAL    { false }
    ::= { juniSystemGeneral 19 }

juniSystemReloadSlotNumber  OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "In a juniSystemReloadCommand notification, this object indicates the
        number of the slot that is being reloaded.  Note that slot numbers are
        zero-based."
    ::= { juniSystemGeneral 20 }

juniSystemUtilizationThresholdDirection  OBJECT-TYPE
    SYNTAX      INTEGER {
                    rising(1),
                    falling(2) }
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The type of resource utilization notification being sent.  See the
        DESCRIPTIONs for the juniSystemUtilizationTable elements for details on
        what conditions trigger a resource utilization notification."
    ::= { juniSystemGeneral 21 }

juniSystemUtilizationTrapEnable  OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Controls the sending of system resource utilization threshold
        notifications.  Setting the value of this object to true(1) will allow
        resource utilization threshold event notifications, if they occur, to be
        sent to the management entity on this system.  Setting the value of this
        object to false(2) will disable resource utilization threshold
        utilization event notifications."
    DEFVAL    { true }
    ::= { juniSystemGeneral 22 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Notifications
--
-- The juniSystemTrap OBJECT IDENTIFIER is used to define SNMPv2 notifications
-- that may be translated into SNMPv1 traps.
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemHighMemUtil  NOTIFICATION-TYPE
    OBJECTS {
        juniSystemMemCapacity,
        juniSystemMemUtilPct,
        juniSystemAbatedMemUtilThreshold,
        juniSystemHighMemUtilThreshold,
        juniSystemMemKBytesCapacity }
    STATUS      current
    DESCRIPTION
        "Report system memory utilization has met the conditions of
        juniSystemHighMemUtilThreshold.  If the memory capacity is greater than
        2147483647, a -1 value is returned in juniSystemMemCapacity, and the
        actual memory capacity in units of 1024 bytes is returned in
        juniSystemMemKBytesCapacity."
    ::= { juniSystemTrap 1 }

juniSystemAbatedMemUtil  NOTIFICATION-TYPE
    OBJECTS {
        juniSystemMemCapacity,
        juniSystemMemUtilPct,
        juniSystemAbatedMemUtilThreshold,
        juniSystemHighMemUtilThreshold,
        juniSystemMemKBytesCapacity }
    STATUS      current
    DESCRIPTION
        "Reports system memory utilization has met the conditions of
        juniSystemAbatedMemUtilThreshold.  If the memory capacity is greater
        than 2147483647, a -1 value is returned in juniSystemMemCapacity, and
        the actual memory capacity in units of 1024 bytes is returned in
        juniSystemMemKBytesCapacity."
    ::= { juniSystemTrap 2 }

juniSystemModuleOperStatusChange  NOTIFICATION-TYPE
    OBJECTS {
        juniSystemModuleCurrentType,
        juniSystemModuleAdminStatus,
        juniSystemModuleOperStatus,
        juniSystemModuleDisableReason,
        juniSystemModuleDescr }
    STATUS      current
    DESCRIPTION
        "Reports a status change for a module.  This trap is generated on a
        transition into a stable state (online or disabled) or on a transition
        out of online.  If redundancy is supported for the module
        (juniSystemModuleRedundancySupported is true(1)), then the
        juniSystemModuleSpareServer and juniSystemModuleAssociatedSlot objects
        are also included in the notification."
    ::= { juniSystemTrap 3 }

juniSystemPowerStatusChange  NOTIFICATION-TYPE
    OBJECTS {
        entPhysicalDescr,
        juniSystemPowerStatus }
    STATUS      current
    DESCRIPTION
        "Reports a change in the status of a power element."
    ::= { juniSystemTrap 4 }

juniSystemFanStatusChange  NOTIFICATION-TYPE
    OBJECTS {
        entPhysicalDescr,
        juniSystemFanStatus }
    STATUS      current
    DESCRIPTION
        "Reports a transition between the three states of the fan subsystem.
        When the fan subsystem transitions to the failed state the Thermal
        Protection hold off time begins."
    ::= { juniSystemTrap 5 }

juniSystemTempStatusChange  NOTIFICATION-TYPE
    OBJECTS {
        juniSystemTempStatus }
    STATUS      current
    DESCRIPTION
        "Reports a change in the temperature status.  When the status
        transitions to the tooHigh state the system enters Thermal Protection
        mode."
    ::= { juniSystemTrap 6 }

juniSystemTempProtectionStatusChange  NOTIFICATION-TYPE
    OBJECTS {
        juniSystemTempProtectionStatus,
        juniSystemTempProtectionHoldOffTimeRemaining }
    STATUS      current
    DESCRIPTION
        "Notification about changes in the state of Thermal Protection.  This
        notification is sent when the tempProtectionStatus changes.  It is also
        sent when the holdOffTimeRemaining is 50% of the holdOffTime."
    ::= { juniSystemTrap 7 }

juniSystemReloadCommand  NOTIFICATION-TYPE
    STATUS      current
    DESCRIPTION
        "Notification indicating that a slot or the entire system is about to
        restart due to a system console reload command.  If the reload is only
        on an individual slot then the following object is included in the
        notification:
            juniSystemReloadSlotNumber "
    ::= { juniSystemTrap 8 }

juniSystemUtilizationThreshold  NOTIFICATION-TYPE
    OBJECTS {
        juniSystemUtilizationThresholdDirection,
        juniSystemUtilizationMaxCapacity,
        juniSystemUtilizationCurrentValue,
        juniSystemUtilizationThresholdRising,
        juniSystemUtilizationThresholdFalling,
        juniSystemUtilizationHoldDownTime }
    STATUS      current
    DESCRIPTION
        "Notification indicating that a system resource's utilization has met
        the conditions of juniSystemUtilizationThresholdDirection.  See the
        DESCRIPTIONs for the juniSystemUtilizationTable elements for details on
        what conditions trigger a resource utilization notification."
    ::= { juniSystemTrap 9 }

juniSystemIssuStateChange    NOTIFICATION-TYPE
    OBJECTS {
        juniSystemIssuState }
    STATUS      current
    DESCRIPTION
        "Notification about changes in the status, in case of ISSU upgrade.
        This notification is sent when the juniSystemIssuState changes. The
        trap parameter will indicate the current value of the
        juniSystemIssuState.

        This notification is supported on the second generation E-series
        platform family (E320 & E120) from 9.0 release onwards. This
        object is also supported on ERX-1440 in JUNOSe 9.2 and
        subsequent system releases."
    ::= { juniSystemTrap 10 }

-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Conformance information
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemCompliances OBJECT IDENTIFIER ::= { juniSystemConformance 1 }
juniSystemGroups      OBJECT IDENTIFIER ::= { juniSystemConformance 2 }

--
-- compliance statements
--
juniSystemCompliance  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "Obsolete compliance statement for entities that implement the Juniper
        E-series System MIB.  This statement became obsolete when system
        resource utilization support was added."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniSystemGeneralGroup,
            juniSystemSubsystemGroup,
            juniSystemModuleGroup,
            juniSystemPortGroup,
            juniSystemTimingGroup,
            juniSystemFabricGroup,
            juniSystemNvsGroup,
            juniSystemPowerGroup,
            juniSystemTemperatureGroup,
            juniSystemNotificationObjectsGroup,
            juniSystemNotificationGroup }
    ::= { juniSystemCompliances 1 }                                -- JUNOSe 4.1

juniSystemCompliance2  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "Obsolete compliance statement for entities that implement the Juniper
        E-series System MIB.  This statement became obsolete when the system
        resource utilization trap enabled and the KByte memory capacilty objects
        were added."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniSystemGeneralGroup,
            juniSystemSubsystemGroup,
            juniSystemModuleGroup,
            juniSystemPortGroup,
            juniSystemTimingGroup,
            juniSystemFabricGroup,
            juniSystemNvsGroup,
            juniSystemPowerGroup,
            juniSystemTemperatureGroup,
            juniSystemUtilizationGroup,
            juniSystemNotificationObjectsGroup,
            juniSystemNotificationGroup2 }
            OBJECT      juniSystemUtilizationMaxCapacity
                MIN-ACCESS  accessible-for-notify
                DESCRIPTION
                    "This object is only required to be included in the
                    juniSystemUtilizationThreshold notifications."
            OBJECT      juniSystemUtilizationCurrentValue
                MIN-ACCESS  accessible-for-notify
                DESCRIPTION
                    "This object is only required to be included in the
                    juniSystemUtilizationThreshold notifications."
            OBJECT      juniSystemUtilizationThresholdRising
                MIN-ACCESS  accessible-for-notify
                DESCRIPTION
                    "This object may have a fixed value in a particular
                    implementation and is therefore only required to be included
                    in the juniSystemUtilizationThreshold notifications."
            OBJECT      juniSystemUtilizationThresholdFalling
                MIN-ACCESS  accessible-for-notify
                DESCRIPTION
                    "This object may have a fixed value in a particular
                    implementation and is therefore only required to be included
                    in the juniSystemUtilizationThreshold notifications."
            OBJECT      juniSystemUtilizationHoldDownTime
                MIN-ACCESS  accessible-for-notify
                DESCRIPTION
                    "This object may have a fixed value in a particular
                    implementation and is therefore only required to be included
                    in the juniSystemUtilizationThreshold notifications."
    ::= { juniSystemCompliances 2 }                                -- JUNOSe 5.0

juniSystemCompliance3  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "Obsolete compliance statement for entities that implement the Juniper
        E-series System MIB.  This statement became obsolete when the module
        level span object was added."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniSystemGeneralGroup2,
            juniSystemSubsystemGroup,
            juniSystemModuleGroup,
            juniSystemPortGroup,
            juniSystemTimingGroup,
            juniSystemFabricGroup,
            juniSystemNvsGroup,
            juniSystemPowerGroup,
            juniSystemTemperatureGroup,
            juniSystemUtilizationGroup,
            juniSystemNotificationObjectsGroup,
            juniSystemNotificationGroup2 }
    ::= { juniSystemCompliances 3 }                                -- JUNOSe 5.2

juniSystemCompliance4  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "Obsolete compliance statement for entities that implement the Juniper
        E-series System MIB."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniSystemGeneralGroup2,
            juniSystemSubsystemGroup,
            juniSystemModuleGroup2,
            juniSystemPortGroup,
            juniSystemTimingGroup,
            juniSystemFabricGroup,
            juniSystemNvsGroup,
            juniSystemPowerGroup,
            juniSystemTemperatureGroup,
            juniSystemUtilizationGroup,
            juniSystemNotificationObjectsGroup,
            juniSystemNotificationGroup2 }
    ::= { juniSystemCompliances 4 }                                -- JUNOSe 6.0

juniSystemCompliance5  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "Obsolete compliance statement for entities that implement the Juniper
        E-series System MIB."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniSystemGeneralGroup2,
            juniSystemSubsystemGroup,
            juniSystemModuleGroup2,
            juniSystemPortGroup,
            juniSystemTimingGroup,
            juniSystemFabricGroup,
            juniSystemNvsGroup,
            juniSystemPowerGroup,
            juniSystemTemperatureGroup,
            juniSystemUtilizationGroup2,
            juniSystemNotificationObjectsGroup,
            juniSystemNotificationGroup2 }
    ::= { juniSystemCompliances 5 }                                -- JUNOSe 7.3

juniSystemCompliance6  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "The compliance statement for entities that implement the Juniper
        E-series System MIB."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniSystemGeneralGroup2,
            juniSystemSubsystemGroup,
            juniSystemModuleGroup3,
            juniSystemPortGroup,
            juniSystemTimingGroup,
            juniSystemFabricGroup,
            juniSystemNvsGroup,
            juniSystemPowerGroup,
            juniSystemTemperatureGroup,
            juniSystemUtilizationGroup2,
            juniSystemNotificationObjectsGroup,
            juniSystemNotificationGroup2 }
    ::= { juniSystemCompliances 6 }                                -- JUNOSe 8.0

juniSystemCompliance7  MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
        "The compliance statement for entities that implement the Juniper
        E-series System MIB."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniSystemGeneralGroup2,
            juniSystemSubsystemGroup,
            juniSystemModuleGroup3,
            juniSystemPortGroup,
            juniSystemTimingGroup,
            juniSystemFabricGroup,
            juniSystemNvsGroup,
            juniSystemPowerGroup,
            juniSystemTemperatureGroup,
            juniSystemUtilizationGroup2,
            juniSystemNotificationObjectsGroup,
            juniSystemIssuGroup,
            juniSystemNotificationGroup3 }
    ::= { juniSystemCompliances 7 }                                -- JUNOSe 9.0
--
-- units of conformance
--
juniSystemGeneralGroup  OBJECT-GROUP
    OBJECTS {
        juniSystemSwVersion,
        juniSystemSwBuildDate,
        juniSystemMemUtilPct,
        juniSystemMemCapacity,
        juniSystemHighMemUtilThreshold,
        juniSystemAbatedMemUtilThreshold,
        juniSystemMemUtilTrapEnable,

        juniSystemBootConfigControl,
        juniSystemBootBackupConfigControl,
        juniSystemBootForceBackupControl,
        juniSystemBootAutoRevertControl,
        juniSystemBootAutoRevertCountTolerance,
        juniSystemBootAutoRevertTimeTolerance,
        juniSystemBootReleaseFile,
        juniSystemBootConfigFile,
        juniSystemBootBackupReleaseFile,
        juniSystemBootBackupConfigFile,

        juniSystemRedundancyRevertControl,
        juniSystemRedundancyRevertTimeOfDay }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of management objects providing system-wide
        software status and control information in a Juniper E-series product.
        This group became obsolete when the system resource utilization
        threshold trap enable/disable and the KByte memory capacilty objects
        were added."
    ::= { juniSystemGroups 1 }                                     -- JUNOSe 4.1

juniSystemSubsystemGroup  OBJECT-GROUP
    OBJECTS {
        juniSystemSubsystemName,
        juniSystemSubsystemBootReleaseFile,
        juniSystemSubsystemBootBackupReleaseFile }
    STATUS      current
    DESCRIPTION
        "A collection of management objects providing subsystem software control
        information in a Juniper E-series product."
    ::= { juniSystemGroups 2 }                                     -- JUNOSe 4.1

juniSystemModuleGroup  OBJECT-GROUP
    OBJECTS {
        juniSystemMaxSlotNumber,
        juniSystemMaxModulesPerSlot,

        juniSystemSlotStatus,
        juniSystemSlotType,

        juniSystemModuleOperStatus,
        juniSystemModuleDisableReason,
        juniSystemModuleLastChange,
        juniSystemModuleCurrentType,
        juniSystemModuleExpectedType,
        juniSystemModuleDescr,
        juniSystemModuleSlotSpan,
        juniSystemModulePortCount,
        juniSystemModuleSerialNumber,
        juniSystemModuleAssemblyPartNumber,
        juniSystemModuleAssemblyRev,
        juniSystemModulePhysicalIndex,
        juniSystemModuleSoftwareSupport,
        juniSystemModuleRedundancySupport,

        juniSystemModuleSoftwareVersion,
        juniSystemModuleCpuUtilPct,
        juniSystemModuleMemUtilPct,
        juniSystemModuleAdminStatus,
        juniSystemModuleControl,
        juniSystemModuleBootReleaseFile,
        juniSystemModuleBootBackupReleaseFile,

        juniSystemModuleRedundancyGroupId,
        juniSystemModuleRedundancySpare,
        juniSystemModuleRedundancyAssociatedSlot,
        juniSystemModuleRedundancyLockout,
        juniSystemModuleRedundancyRevertControl,
        juniSystemModuleRedundancyRevertTime }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of management objects that provide system module
        information in a Juniper E-series product.  This group became obsolete
        when the module level span object was added."
    ::= { juniSystemGroups 3 }                                     -- JUNOSe 4.1

juniSystemPortGroup  OBJECT-GROUP
    OBJECTS {
        juniSystemPortPhysicalIndex,
        juniSystemPortIfIndex }
    STATUS      current
    DESCRIPTION
        "A collection of management objects providing physical I/O port
        information in a Juniper E-series product."
    ::= { juniSystemGroups 4 }                                     -- JUNOSe 4.1

juniSystemTimingGroup  OBJECT-GROUP
    OBJECTS {
        juniSystemAdminTimingSource,
        juniSystemOperTimingSource,
        juniSystemTimingAutoUpgrade,

        juniSystemTimingSourceType,
        juniSystemTimingSourceIfIndex,
        juniSystemTimingSourceLine,
        juniSystemTimingWorkingStatus,
        juniSystemTimingProtectedStatus }
    STATUS      current
    DESCRIPTION
        "A collection of management objects providing system timing source
        information in a Juniper E-series product."
    ::= { juniSystemGroups 5 }                                     -- JUNOSe 4.1

juniSystemFabricGroup  OBJECT-GROUP
    OBJECTS {
        juniSystemFabricSpeed,
        juniSystemFabricRev }
    STATUS      current
    DESCRIPTION
        "A collection of management objects providing system fabric information
        in a Juniper E-series product."
    ::= { juniSystemGroups 6 }                                     -- JUNOSe 4.1

juniSystemNvsGroup  OBJECT-GROUP
    OBJECTS {
        juniSystemNvsCount,

        juniSystemNvsPhysicalIndex,
        juniSystemNvsStatus,
        juniSystemNvsCapacity,
        juniSystemNvsUtilPct }
    STATUS      current
    DESCRIPTION
        "A collection of management objects providing system non-volatile
        storage (NVS) information in a Juniper E-series product."
    ::= { juniSystemGroups 7 }                                     -- JUNOSe 4.1

juniSystemPowerGroup  OBJECT-GROUP
    OBJECTS {
        juniSystemPowerCount,

        juniSystemPowerPhysicalIndex,
        juniSystemPowerStatus }
    STATUS      current
    DESCRIPTION
        "A collection of management objects providing system power element
        information in a Juniper E-series product."
    ::= { juniSystemGroups 8 }                                     -- JUNOSe 4.1

juniSystemTemperatureGroup  OBJECT-GROUP
    OBJECTS {
        juniSystemFanCount,

        juniSystemFanPhysicalIndex,
        juniSystemFanStatus,

        juniSystemTempCount,

        juniSystemTempStatus,
        juniSystemTempValue,
        juniSystemTempPhysicalIndex,

        juniSystemTempProtectionStatus,
        juniSystemTempProtectionHoldOffTime,
        juniSystemTempProtectionHoldOffTimeRemaining }
    STATUS      current
    DESCRIPTION
        "A collection of management objects providing system temperature control
        information in a Juniper E-series product."
    ::= { juniSystemGroups 9 }                                     -- JUNOSe 4.1

juniSystemNotificationObjectsGroup  OBJECT-GROUP
    OBJECTS {
        juniSystemReloadSlotNumber }
    STATUS      current
    DESCRIPTION
        "A collection of management objects providing system information for
        notification in a Juniper E-series product."
    ::= { juniSystemGroups 10 }                                    -- JUNOSe 4.1

juniSystemNotificationGroup  NOTIFICATION-GROUP
    NOTIFICATIONS {
        juniSystemHighMemUtil,
        juniSystemAbatedMemUtil,
        juniSystemModuleOperStatusChange,
        juniSystemPowerStatusChange,
        juniSystemFanStatusChange,
        juniSystemTempStatusChange,
        juniSystemTempProtectionStatusChange,
        juniSystemReloadCommand }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of notifications for system events in a Juniper
        E-series product.  This group became obsolete when the system resource
        utilization notification was added."
    ::= { juniSystemGroups 11 }                                    -- JUNOSe 4.1

juniSystemUtilizationGroup  OBJECT-GROUP
    OBJECTS {
        juniSystemUtilizationMaxCapacity,
        juniSystemUtilizationCurrentValue,
        juniSystemUtilizationThresholdRising,
        juniSystemUtilizationThresholdFalling,
        juniSystemUtilizationHoldDownTime,
        juniSystemUtilizationThresholdDirection }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of management objects providing system resource
        utilization information and notification control for a Juniper E-series
        product."
    ::= { juniSystemGroups 12 }                                    -- JUNOSe 5.0

juniSystemNotificationGroup2  NOTIFICATION-GROUP
    NOTIFICATIONS {
        juniSystemHighMemUtil,
        juniSystemAbatedMemUtil,
        juniSystemModuleOperStatusChange,
        juniSystemPowerStatusChange,
        juniSystemFanStatusChange,
        juniSystemTempStatusChange,
        juniSystemTempProtectionStatusChange,
        juniSystemReloadCommand,
        juniSystemUtilizationThreshold }
    STATUS      obsolete
    DESCRIPTION
        "A collection of notifications for system events in a Juniper E-series
        product."
    ::= { juniSystemGroups 13 }                                    -- JUNOSe 5.0

juniSystemGeneralGroup2  OBJECT-GROUP
    OBJECTS {
        juniSystemSwVersion,
        juniSystemSwBuildDate,
        juniSystemMemUtilPct,
        juniSystemMemCapacity,
        juniSystemMemKBytesCapacity,
        juniSystemHighMemUtilThreshold,
        juniSystemAbatedMemUtilThreshold,
        juniSystemMemUtilTrapEnable,
        juniSystemUtilizationTrapEnable,

        juniSystemBootConfigControl,
        juniSystemBootBackupConfigControl,
        juniSystemBootForceBackupControl,
        juniSystemBootAutoRevertControl,
        juniSystemBootAutoRevertCountTolerance,
        juniSystemBootAutoRevertTimeTolerance,
        juniSystemBootReleaseFile,
        juniSystemBootConfigFile,
        juniSystemBootBackupReleaseFile,
        juniSystemBootBackupConfigFile,

        juniSystemRedundancyRevertControl,
        juniSystemRedundancyRevertTimeOfDay }
    STATUS      current
    DESCRIPTION
        "A collection of management objects providing system-wide software
        status and control information in a Juniper E-series product."
    ::= { juniSystemGroups 14 }                                    -- JUNOSe 5.2

juniSystemModuleGroup2  OBJECT-GROUP
    OBJECTS {
        juniSystemMaxSlotNumber,
        juniSystemMaxModulesPerSlot,

        juniSystemSlotStatus,
        juniSystemSlotType,

        juniSystemModuleOperStatus,
        juniSystemModuleDisableReason,
        juniSystemModuleLastChange,
        juniSystemModuleCurrentType,
        juniSystemModuleExpectedType,
        juniSystemModuleDescr,
        juniSystemModuleSlotSpan,
        juniSystemModulePortCount,
        juniSystemModuleSerialNumber,
        juniSystemModuleAssemblyPartNumber,
        juniSystemModuleAssemblyRev,
        juniSystemModulePhysicalIndex,
        juniSystemModuleSoftwareSupport,
        juniSystemModuleRedundancySupport,
        juniSystemModuleLevelSpan,

        juniSystemModuleSoftwareVersion,
        juniSystemModuleCpuUtilPct,
        juniSystemModuleMemUtilPct,
        juniSystemModuleAdminStatus,
        juniSystemModuleControl,
        juniSystemModuleBootReleaseFile,
        juniSystemModuleBootBackupReleaseFile,

        juniSystemModuleRedundancyGroupId,
        juniSystemModuleRedundancySpare,
        juniSystemModuleRedundancyAssociatedSlot,
        juniSystemModuleRedundancyLockout,
        juniSystemModuleRedundancyRevertControl,
        juniSystemModuleRedundancyRevertTime }
    STATUS      obsolete
    DESCRIPTION
        "A collection of management objects that provide system module
        information in a Juniper E-series product."
    ::= { juniSystemGroups 15 }                                    -- JUNOSe 6.0

juniSystemUtilizationGroup2  OBJECT-GROUP
    OBJECTS {
        juniSystemUtilizationMaxCapacity,
        juniSystemUtilizationCurrentValue,
        juniSystemUtilizationThresholdRising,
        juniSystemUtilizationThresholdFalling,
        juniSystemUtilizationHoldDownTime,
        juniSystemUtilizationThresholdDirection,        
        juniSystemCpuUtilizationTaskName,
        juniSystemCpuUtilizationInvoked,
        juniSystemCpuUtilizationInvokationPerSec,
        juniSystemCpuUtilizationTotalRunningTime,
        juniSystemCpuUtilizationPercentageRunningTime,    
        juniSystemCpuUtilizationAverageTimePerInvokation,
        juniSystemCpuUtilizationFiveSecondUtilization,    
        juniSystemCpuUtilizationOneMinuteUtilization,
        juniSystemCpuUtilizationFiveMinuteUtilization,
        juniSystemCpuUtilizationNumberOfInstances }
    STATUS      current
    DESCRIPTION
        "A collection of management objects providing system resource
        utilization information and notification control for a Juniper E-series
        product."
    ::= { juniSystemGroups 16 }                                    -- JUNOSe 7.3  

juniSystemModuleGroup3  OBJECT-GROUP
    OBJECTS {
        juniSystemMaxSlotNumber,
        juniSystemMaxModulesPerSlot,

        juniSystemSlotStatus,
        juniSystemSlotType,

        juniSystemModuleOperStatus,
        juniSystemModuleDisableReason,
        juniSystemModuleLastChange,
        juniSystemModuleCurrentType,
        juniSystemModuleExpectedType,
        juniSystemModuleDescr,
        juniSystemModuleSlotSpan,
        juniSystemModulePortCount,
        juniSystemModuleSerialNumber,
        juniSystemModuleAssemblyPartNumber,
        juniSystemModuleAssemblyRev,
        juniSystemModulePhysicalIndex,
        juniSystemModuleSoftwareSupport,
        juniSystemModuleRedundancySupport,
        juniSystemModuleLevelSpan,

        juniSystemModuleSoftwareVersion,
        juniSystemModuleCpuUtilPct,
        juniSystemModuleMemUtilPct,
        juniSystemModuleAdminStatus,
        juniSystemModuleControl,
        juniSystemModuleBootReleaseFile,
        juniSystemModuleBootBackupReleaseFile,
        juniSystemModuleCpuFiveSecUtilPct,
        juniSystemModuleCpuOneMinAvgPct,
        juniSystemModuleCpuFiveMinAvgPct,

        juniSystemModuleRedundancyGroupId,
        juniSystemModuleRedundancySpare,
        juniSystemModuleRedundancyAssociatedSlot,
        juniSystemModuleRedundancyLockout,
        juniSystemModuleRedundancyRevertControl,
        juniSystemModuleRedundancyRevertTime }
    STATUS      current
    DESCRIPTION
        "A collection of management objects that provide system module
        information in a Juniper E-series product."
    ::= { juniSystemGroups 17 }                                    -- JUNOSe 8.0

juniSystemIssuGroup	OBJECT-GROUP
	OBJECTS	{
        juniSystemIssuState,
        juniSystemIssuArmedReleaseFile,
        juniSystemIssuRunningReleaseFile,
        juniSystemIssuStatus,

        juniSystemIssuCriteriaDescription,
        juniSystemIssuCriteriaStatus }
	STATUS		current
	DESCRIPTION
        "A collection of management objects that provide ISSU related
        information in a Juniper E-series product."
	::= { juniSystemGroups 18 }                                   -- JUNOSe 9.0

juniSystemNotificationGroup3	NOTIFICATION-GROUP
	NOTIFICATIONS	{
        juniSystemHighMemUtil,
        juniSystemAbatedMemUtil,
        juniSystemModuleOperStatusChange,
        juniSystemPowerStatusChange,
        juniSystemFanStatusChange,
        juniSystemTempStatusChange,
        juniSystemTempProtectionStatusChange,
        juniSystemReloadCommand,
        juniSystemUtilizationThreshold,
        juniSystemIssuStateChange }
	STATUS		current
	DESCRIPTION		
        "A collection of notifications for system events in a Juniper E-series
        product."
	::= { juniSystemGroups 19 }                                   -- JUNOSe 9.0

END