summaryrefslogtreecommitdiff
path: root/MIBS/ubnt/UBNT-UFIBER-MIB
blob: ddc03dd630bac2eacf0fff499b720ce16ad35502 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
UBNT-UFIBER-MIB DEFINITIONS ::= BEGIN
    IMPORTS
        MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32, Counter64,
        IpAddress, TimeTicks FROM SNMPv2-SMI
        DisplayString, TruthValue, MacAddress FROM SNMPv2-TC
        OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF
        ubntEdgeMaxGroups, ubntMIB FROM UBNT-MIB;

    ubntEdgeMax MODULE-IDENTITY
    LAST-UPDATED "201801030000Z"
    ORGANIZATION "Ubiquiti Networks, Inc."
    CONTACT-INFO "support@ubnt.com"
    DESCRIPTION  "The EdgeMax MIB module for Ubiquiti Networks, Inc. entities"
    REVISION "201801030000Z"
    DESCRIPTION "ubntEdgeMax revision"
    ::= { ubntMIB 5 }

    -- --------------------------------------------------------------------------------
    --                            product identification
    -- --------------------------------------------------------------------------------

    ubntProductIdent     OBJECT IDENTIFIER ::= { ubntEdgeMax 1 }

    ubntModel OBJECT-TYPE
        SYNTAX     DisplayString
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "Product model."
        ::= { ubntProductIdent 1 }

    ubntSerialNumber OBJECT-TYPE
        SYNTAX     DisplayString
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "Serial number."
        ::= { ubntProductIdent 2 }

    ubntVersion OBJECT-TYPE
        SYNTAX     DisplayString
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "Firmware version."
        ::= { ubntProductIdent 3 }

    -- --------------------------------------------------------------------------------
    --                              power outputs
    -- --------------------------------------------------------------------------------

    ubntPowerOuts         OBJECT IDENTIFIER ::= { ubntEdgeMax 2 }

    ubntPowerOutsCount OBJECT-TYPE
        SYNTAX     Unsigned32
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "The number of power outputs present on this system."
        ::= { ubntPowerOuts 1 }

    ubntPowerOutTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF UbntPowerOutEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION "A list of power out entries. The number of entries is given by the value of ubntPowerOutsCount."
        ::= { ubntPowerOuts 2 }

    ubntPowerOutEntry OBJECT-TYPE
       SYNTAX     UbntPowerOutEntry
       MAX-ACCESS not-accessible
       STATUS     current
       DESCRIPTION "An entry in the ubntPowerOutTable."
       INDEX      { ubntPowerOutIndex }
       ::= { ubntPowerOutTable 1 }

    UbntPowerOutTable ::= SEQUENCE {
        ubntPowerOutIndex   Integer32,
        ubntPowerOutVoltage Integer32,
        ubntPowerOutCurrent Integer32,
        ubntPowerOutPower   Integer32
    }

    ubntPowerOutIndex OBJECT-TYPE
        SYNTAX     Integer32 (1..255)
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "A unique value for each power output."
        ::= { ubntPowerOutEntry 1 }

    ubntPowerOutVoltage OBJECT-TYPE
        SYNTAX     Integer32
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "Output voltage in mV."
        ::= { ubntPowerOutEntry 2 }

    ubntPowerOutCurrent OBJECT-TYPE
        SYNTAX     Integer32
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "Output current in mA."
        ::= { ubntPowerOutEntry 3 }

    ubntPowerOutPower OBJECT-TYPE
        SYNTAX     Integer32
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "Output power in mW."
        ::= { ubntPowerOutEntry 4 }

    -- --------------------------------------------------------------------------------
    --                            power supplies
    -- --------------------------------------------------------------------------------

    ubntPowerSupplies    OBJECT IDENTIFIER ::= { ubntEdgeMax 3 }

    ubntPsuBaysNumber OBJECT-TYPE
        SYNTAX     Unsigned32
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "The number of PSU bays available on this system."
        ::= { ubntPowerSupplies 1 }

    ubntPsuTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF UbntPsuEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION "A list of PSU entries. The number of entries is given by the value of ubntPsuBaysNumber."
        ::= { ubntPowerSupplies 2 }

    ubntPsuEntry OBJECT-TYPE
       SYNTAX     UbntPsuEntry
       MAX-ACCESS not-accessible
       STATUS     current
       DESCRIPTION "An entry in the ubntPsuTable."
       INDEX      { ubntPsuIndex }
       ::= { ubntPsuTable 1 }

    UbntPsuEntry ::= SEQUENCE {
        ubntPsuIndex             Integer32,
        ubntPsuType              Integer32,
        ubntPsuStatus            Integer32,
        ubntPsuOperStatus        Integer32,
        ubntPsuVoltage           Integer32,
        ubntPsuTemperature       Integer32,
        ubntPsuCharging          Integer32,
        ubntPsuBatteryQuantity   Integer32
    }

    ubntPsuIndex OBJECT-TYPE
        SYNTAX     Integer32 (1..255)
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "A unique value for each PSU."
        ::= { ubntPsuEntry 1 }

    ubntPsuType OBJECT-TYPE
        SYNTAX     INTEGER { unknown(0),ac(1),dc(2),poe(3) }
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "PSU Type."
        ::= { ubntPsuEntry 2 }

    ubntPsuStatus OBJECT-TYPE
        SYNTAX     INTEGER { unknown(0),on(1),off(2),standby(3) }
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "PSU Status."
        ::= { ubntPsuEntry 3 }

    ubntPsuOperStatus OBJECT-TYPE
        SYNTAX     INTEGER { down(0),up(1) }
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "PSU operational status."
        ::= { ubntPsuEntry 4 }

    ubntPsuVoltage OBJECT-TYPE
        SYNTAX     Integer32
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "PSU voltage in mV."
        ::= { ubntPsuEntry 5 }

    ubntPsuTemperature OBJECT-TYPE
        SYNTAX     Integer32
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "PSU temperature in thousands of degrees Celsius."
        ::= { ubntPsuEntry 6 }

    ubntPsuCharging OBJECT-TYPE
        SYNTAX     INTEGER { unknown(0),on(1),off(2) }
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "Shows PSU charging state if it is supported."
        ::= { ubntPsuEntry 7 }

    ubntPsuBatteryQuantity OBJECT-TYPE
        SYNTAX     Integer32
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "Number of batteries connected to PSU."
        ::= { ubntPsuEntry 8 }

    -- --------------------------------------------------------------------------------
    --                             thermometers
    -- --------------------------------------------------------------------------------

    ubntThermometers     OBJECT IDENTIFIER ::= { ubntEdgeMax 4 }

    ubntThermometersCount OBJECT-TYPE
        SYNTAX     Unsigned32
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "The number of installed thermometers on this system."
        ::= { ubntThermometers 1 }

    ubntThermsTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF UbntThermsEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION "A list of thermometers entries. The number of entries is given by the value of ubntThermometersCount."
        ::= { ubntThermometers 2 }

    ubntThermsEntry OBJECT-TYPE
        SYNTAX     UbntThermsEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION "An entry in the ubntThermsTable."
        INDEX      { ubntThermIndex }
        ::= { ubntThermsTable 1 }

    UbntThermsEntry ::= SEQUENCE {
        ubntThermIndex        Integer32,
        ubntThermType         Integer32,
        ubntThermTemperature  Integer32
    }

    ubntThermIndex OBJECT-TYPE
        SYNTAX     Integer32 (1..255)
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "A unique value for thermometer."
        ::= { ubntThermsEntry 1 }

    ubntThermType OBJECT-TYPE
        SYNTAX     INTEGER { other(0),board(1),cpu(2),power(3) }
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "Type of thermometer."
        ::= { ubntThermsEntry 2 }

    ubntThermTemperature OBJECT-TYPE
        SYNTAX     Integer32
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "Temperature in thousands of degrees Celsius."
        ::= { ubntThermsEntry 3 }

    -- --------------------------------------------------------------------------------
    --                                  fans
    -- --------------------------------------------------------------------------------

    ubntFans             OBJECT IDENTIFIER ::= { ubntEdgeMax 5 }

    ubntFansCount OBJECT-TYPE
        SYNTAX     Unsigned32
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "The number of installed fans on this system."
        ::= { ubntFans 1 }

    ubntFansTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF UbntFanEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION "A list of fan entries. The number of entries is given by the value of ubntFansCount."
        ::= { ubntFans 2 }

    ubntFanEntry OBJECT-TYPE
        SYNTAX     UbntFanEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION "An entry in the ubntFansTable."
        INDEX      { ubntFanIndex }
        ::= { ubntFansTable 1 }

    UbntFanEntry ::= SEQUENCE {
        ubntFanIndex      Integer32,
        ubntFanType       Integer32,
        ubntFanRpm        Integer32
    }

    ubntFanIndex OBJECT-TYPE
        SYNTAX     Integer32 (1..255)
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "A unique value for fan."
        ::= { ubntFanEntry 1 }

    ubntFanType OBJECT-TYPE
        SYNTAX     INTEGER { other(0),board(1),cpu(2),power(3) }
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "Type of fan."
        ::= { ubntFanEntry 2 }

    ubntFanRpm OBJECT-TYPE
        SYNTAX     Integer32
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "Fan RPM."
        ::= { ubntFanEntry 3 }

    -- --------------------------------------------------------------------------------
    --                                  gpon ONUs
    -- --------------------------------------------------------------------------------
    
    UbntOnuSN ::= TEXTUAL-CONVENTION
        STATUS      current
        SYNTAX      DisplayString (SIZE (0..12))

    SignalLevel ::= TEXTUAL-CONVENTION
        STATUS          current
        DISPLAY-HINT    "d-2"
        SYNTAX          Integer32

    ubntOnus OBJECT IDENTIFIER ::= { ubntEdgeMax 6 }

    ubntOnusCount OBJECT-TYPE
        SYNTAX     Unsigned32
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntOnus 1 }

    ubntOnusTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF UbntOnuEntry
        MAX-ACCESS not-accessible
        STATUS     current
        ::= { ubntOnus 2 }

    ubntOnuEntry OBJECT-TYPE
        SYNTAX     UbntOnuEntry
        MAX-ACCESS not-accessible
        STATUS     current
        INDEX      { ubntOnuIndex }
        ::= { ubntOnusTable 1 }

    UbntOnuEntry ::= SEQUENCE {
        ubntOnuIndex          Integer32,
        ubntOnuSN             Integer32,
        ubntOnuName           DisplayString,
        ubntOnuOnline         TruthValue,
        ubntOnuModel          DisplayString,
        ubntOnuPort           Integer32,
        ubntOnuConnectedTime  TimeTicks,
        ubntOnuUpTime         TimeTicks,
        ubntOnuTxPower        SignalLevel,
        ubntOnuRxPower        SignalLevel,
        ubntOnuTxBytes        Counter64,
        ubntOnuRxBytes        Counter64
    }


    ubntOnuIndex OBJECT-TYPE
        SYNTAX     Integer32
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntOnuEntry 1 }

    ubntOnuSN OBJECT-TYPE
        SYNTAX UbntOnuSN
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntOnuEntry 1 }

    ubntOnuName OBJECT-TYPE
        SYNTAX     DisplayString
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntOnuEntry 2 }
    
    ubntOnuOnline OBJECT-TYPE
        SYNTAX     TruthValue
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntOnuEntry 3 }

    ubntOnuModel OBJECT-TYPE
        SYNTAX     DisplayString (SIZE (0..16))
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntOnuEntry 4 }

    ubntOnuOltPort OBJECT-TYPE
        SYNTAX     Integer32
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntOnuEntry 5 }

    ubntOnuConnectedTime OBJECT-TYPE
        SYNTAX     TimeTicks
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntOnuEntry 6 }

    ubntOnuUpTime OBJECT-TYPE
        SYNTAX     TimeTicks
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntOnuEntry 7 }

    ubntOnuTxPower OBJECT-TYPE
        SYNTAX     SignalLevel
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "in hundredths of dBm"
        ::= { ubntOnuEntry 8 }

    ubntOnuRxPower OBJECT-TYPE
        SYNTAX     SignalLevel
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "in hundredths of dBm"
        ::= { ubntOnuEntry 9 }

    ubntOnuTxBytes OBJECT-TYPE
        SYNTAX     Counter64
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntOnuEntry 10 }

    ubntOnuRxBytes OBJECT-TYPE
        SYNTAX     Counter64
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntOnuEntry 11 }

    -- --------------------------------------------------------------------------------
    --                                  SFP 
    -- --------------------------------------------------------------------------------

    ubntSfps OBJECT IDENTIFIER ::= { ubntEdgeMax 7 }

    ubntSfpsCount OBJECT-TYPE
        SYNTAX     Unsigned32
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION "The number of SFPs"
        ::= { ubntSfps 1 }

    ubntSfpsTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF UbntSfpEntry
        MAX-ACCESS not-accessible
        STATUS     current
        ::= { ubntSfps 2 }


    ubntSfpEntry OBJECT-TYPE
        SYNTAX     UbntSfpEntry
        MAX-ACCESS not-accessible
        STATUS     current
        INDEX      { ubntSfpIndex }
        ::= { ubntSfpsTable 1 }

    UbntSfpEntry ::= SEQUENCE {
        ubntSfpIndex          Integer32,
        ubntSfpUp             TruthValue,
        ubntSfpVendor         DisplayString,
        ubntSfpVendorPn       DisplayString,
        ubntSfpTxBytes        Counter64,
        ubntSfpRxBytes        Counter64
    }
    
    ubntSfpIndex OBJECT-TYPE
        SYNTAX     Integer32
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntSfpEntry 1 }

    ubntSfpName OBJECT-TYPE
        SYNTAX     DisplayString
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntSfpEntry 2 }

    ubntSfpUp OBJECT-TYPE
        SYNTAX     TruthValue
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntSfpEntry 3 }

    ubntSfpVendor OBJECT-TYPE
        SYNTAX     DisplayString (SIZE (0..16))
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntSfpEntry 4 }

    ubntSfpVendorPn OBJECT-TYPE
        SYNTAX     DisplayString (SIZE (0..16))
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntSfpEntry 5 }

    ubntSfpTxBytes OBJECT-TYPE
        SYNTAX     Counter64
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntSfpEntry 6 }

    ubntSfpRxBytes OBJECT-TYPE
        SYNTAX     Counter64
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntSfpEntry 7 }
    

    -- --------------------------------------------------------------------------------
    --                                  gpon ONU ports
    -- --------------------------------------------------------------------------------

    ubntOnuPorts OBJECT IDENTIFIER ::= { ubntEdgeMax 8 }

    ubntOnuPortsTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF UbntOnuPortEntry
        MAX-ACCESS not-accessible
        STATUS     current
        ::= { ubntOnuPorts 1 }

    ubntOnuPortEntry OBJECT-TYPE
        SYNTAX     UbntOnuPortEntry
        MAX-ACCESS not-accessible
        STATUS     current
        INDEX      { ubntOnuPortSN, ubntOnuPortIndex }
        ::= { ubntOnuPortsTable 1 }

    UbntOnuPortEntry ::= SEQUENCE {
        ubntOnuPortSN         UbntOnuSN,
        ubntOnuPortIndex      Integer32,
        ubntOnuPortIfSpeed    Gauge32
    }

    ubntOnuPortSN OBJECT-TYPE
        SYNTAX     UbntOnuSN
        MAX-ACCESS read-only
        STATUS     current
        ::= { ubntOnuPortEntry 1 }

    ubntOnuPortIndex OBJECT-TYPE
        SYNTAX     Integer32
        MAX-ACCESS read-only
        STATUS     current
        ::= {ubntOnuPortEntry 2 }

    ubntOnuPortIfSpeed OBJECT-TYPE
        SYNTAX      Gauge32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "in bits per second, see IF-MIB::ifSpeed"
        ::= { ubntOnuPortEntry 3 }

END