summaryrefslogtreecommitdiff
path: root/MIBS/telco-systems/binox/PRVT-EPS-MIB
blob: 8340e3e1dd365a8711214d06edfc6baa213f11c5 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-EPS-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------

PRVT-EPS-MIB DEFINITIONS ::= BEGIN

IMPORTS
    switch
        FROM PRVT-SWITCH-MIB
    MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, Unsigned32
        FROM SNMPv2-SMI
    RowStatus, TEXTUAL-CONVENTION, TruthValue
        FROM SNMPv2-TC;

prvtEpsMIB MODULE-IDENTITY
    LAST-UPDATED "201011110000Z"
    ORGANIZATION 
        "BATM Advanced Communication"
    CONTACT-INFO 
        "BATM/Telco Systems Support team
         Email:
         For North America: techsupport@telco.com
         For North Europe: support@batm.de, info@batm.de
         For the rest of the world: techsupport@telco.com"
    DESCRIPTION 
        "Private MIB supporting Linear Ethernet Protection Switching (ITU-T G.8031)"
    REVISION    "201011110000Z"
    DESCRIPTION 
        "Initial"
    ::= { switch 132 }


PrvtEpsProtectionStateType ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION 
        "Possible protection states for an end device."
    SYNTAX      INTEGER { none(-1), noRequest(0), doNotRevert(1), 
                    reverseRequest(2), exercise(4), waitToRestore(5), 
                    clear(6), manualSwitch(7), signalDegrade(9), 
                    signalFail(11), forcedSwitch(13), 
                    signalFailForProtection(14), lockoutOfProtection(15) }

PrvtEpsActionType ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION 
        "Used to perform an action.
         Setting to 'performAction' will cause the action to be performed.
         Setting to 'idle' (or any other value except 'performAction') has
         no effect (no action is performed).
         Reads will always return 'idle'."
    SYNTAX      INTEGER { idle(1), performAction(2) }

prvtEpsMIBNotifications OBJECT IDENTIFIER
    ::= { prvtEpsMIB 0 }

prvtEpsMIBObjects OBJECT IDENTIFIER
    ::= { prvtEpsMIB 1 }

prvtEpsService OBJECT IDENTIFIER
    ::= { prvtEpsMIBObjects 1 }

prvtEpsServiceTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PrvtEpsServiceEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "This table contains Ethernet Protection Switching services information."
    ::= { prvtEpsService 1 }

prvtEpsServiceEntry OBJECT-TYPE
    SYNTAX      PrvtEpsServiceEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "Ethernet Protection Switching information about a specific service."
    INDEX       { prvtEpsSvcId }
    ::= { prvtEpsServiceTable 1 }

PrvtEpsServiceEntry ::= SEQUENCE {
    prvtEpsSvcId                            Unsigned32,
    prvtEpsServiceRowStatus                 RowStatus,
    prvtEpsServiceCfmMdLevel                Unsigned32,
    prvtEpsServicePrimaryLocalCfmMep        Unsigned32,
    prvtEpsServicePrimaryRemoteCfmMep       Unsigned32,
    prvtEpsServiceSecondaryLocalCfmMep      Unsigned32,
    prvtEpsServiceSecondaryRemoteCfmMep     Unsigned32,
    prvtEpsServiceSignalDegradeCfmTestId    Unsigned32,
    prvtEpsServiceRevertive                 TruthValue,
    prvtEpsServiceHoldOffTimer              Unsigned32,
    prvtEpsServiceWaitToRestoreTimer        Unsigned32,
    prvtEpsServiceAdminFreeze               TruthValue,
    prvtEpsServiceAdminStatus               INTEGER,
    prvtEpsServiceActivePath                INTEGER,
    prvtEpsServiceDefectsPresent            BITS,
    prvtEpsServiceLocalState                PrvtEpsProtectionStateType,
    prvtEpsServiceOperationalStatus         TruthValue,
    prvtEpsServiceLastEvent                 INTEGER,
    prvtEpsServicePrimaryStatus             INTEGER,
    prvtEpsServiceSecondaryStatus           INTEGER,
    prvtEpsServiceRemoteState               PrvtEpsProtectionStateType,
    prvtEpsServiceRemoteApsChannel          INTEGER,
    prvtEpsServiceRemoteProtection          INTEGER,
    prvtEpsServiceRemoteDirection           INTEGER,
    prvtEpsServiceRemoteRevertive           INTEGER,
    prvtEpsServiceLocalApsChannel           INTEGER,
    prvtEpsServiceLocalProtection           INTEGER,
    prvtEpsServiceLocalDirection            INTEGER,
    prvtEpsServiceClear                     PrvtEpsActionType,
    prvtEpsServiceManualSwitch              PrvtEpsActionType,
    prvtEpsServiceForcedSwitch              PrvtEpsActionType,
    prvtEpsServiceLockout                   PrvtEpsActionType,
    prvtEpsServiceProtectionCounter         Unsigned32
}

prvtEpsSvcId OBJECT-TYPE
    SYNTAX      Unsigned32 (1..4294967294)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "The service ID."
    ::= { prvtEpsServiceEntry 1 }

prvtEpsServiceRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "The status of the row.
         The writable columns in a row can not be changed if the row
         is active. All columns must have a valid value before a row
         can be activated."
    ::= { prvtEpsServiceEntry 2 }

prvtEpsServiceCfmMdLevel OBJECT-TYPE
    SYNTAX      Unsigned32 (0..7)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Value of the CFM MD level where the protected domain is situated."
    ::= { prvtEpsServiceEntry 3 }

prvtEpsServicePrimaryLocalCfmMep OBJECT-TYPE
    SYNTAX      Unsigned32 (1..8191)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Primary local CFM MEP Id."
    ::= { prvtEpsServiceEntry 4 }

prvtEpsServicePrimaryRemoteCfmMep OBJECT-TYPE
    SYNTAX      Unsigned32 (1..8191)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Primary remote CFM MEP Id."
    ::= { prvtEpsServiceEntry 5 }

prvtEpsServiceSecondaryLocalCfmMep OBJECT-TYPE
    SYNTAX      Unsigned32 (1..8191)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Backup local CFM MEP Id."
    ::= { prvtEpsServiceEntry 6 }

prvtEpsServiceSecondaryRemoteCfmMep OBJECT-TYPE
    SYNTAX      Unsigned32 (1..8191)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Backup remote CFM MEP Id."
    ::= { prvtEpsServiceEntry 7 }

prvtEpsServiceSignalDegradeCfmTestId OBJECT-TYPE
    SYNTAX      Unsigned32 (0..256)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "The ID of the test used for monitoring (either CFM or SAA test).
         The value 0 indicates no test."
    ::= { prvtEpsServiceEntry 8 }

prvtEpsServiceRevertive OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Protection type (revertive or non-revertive)."
    ::= { prvtEpsServiceEntry 9 }

prvtEpsServiceHoldOffTimer OBJECT-TYPE
    SYNTAX      Unsigned32 (0..10000)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Value of the Hold Off timer in milliseconds.
         Valid values are in increments of 100ms."
    REFERENCE   
        "G.8031 clause 11.12"
    ::= { prvtEpsServiceEntry 10 }

prvtEpsServiceWaitToRestoreTimer OBJECT-TYPE
    SYNTAX      Unsigned32 (0 | 5..12)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Value of the Wait To Restore timer in seconds (0 to disable it)."
    REFERENCE   
        "G.8031 clause 11.13"
    ::= { prvtEpsServiceEntry 11 }

prvtEpsServiceAdminFreeze OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Used to freeze the state of the protection service."
    ::= { prvtEpsServiceEntry 12 }

prvtEpsServiceAdminStatus OBJECT-TYPE
    SYNTAX      INTEGER { up(1), down(2) }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Administrative status of the protection service."
    ::= { prvtEpsServiceEntry 13 }

prvtEpsServiceActivePath OBJECT-TYPE
    SYNTAX      INTEGER { working(0), protection(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Protected service active path."
    ::= { prvtEpsServiceEntry 14 }

prvtEpsServiceDefectsPresent OBJECT-TYPE
    SYNTAX      BITS { fullyIncompatibleProvisioning(0), 
                    protectionSwitchingIncomplete(1), 
                    protectionConfigurationMismatch(2), 
                    epsConfigurationMismatch(3) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Defects registered by the APS protocol could be either none or a composition of bits 0-3:
         
         fullyIncompatibleProvisioning(0)   - occurs upon reception of three APS frames with the
         incompatible 'B' bit value within the 22.5 second period;
         
         protectionSwitchingIncomplete(1)   - occurs if the transmitted 'Requested Signal' and the
         received 'Bridged Signal' do not match for a period of 50ms or longer;
         
         protectionConfigurationMismatch(2) - working/protection configuration mismatch, occurs at
         the reception of three APS frames from the working transport entity within the 22.5 second period;
         
         epsConfigurationMismatch(3)        - provisioning mismatch - for example, the local device is
         set to revertive mode and the remote device is set to non-revertive mode."
    ::= { prvtEpsServiceEntry 15 }

prvtEpsServiceLocalState OBJECT-TYPE
    SYNTAX      PrvtEpsProtectionStateType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Protection state of the local side."
    ::= { prvtEpsServiceEntry 19 }

prvtEpsServiceOperationalStatus OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Identifies whether this service is ready for running.
         The operational status can be up(true) or down(false).
         When creating the service the operational
         status will be down. Receiving CCMs from both transport
         entities and establishment of APS on the protection transport
         entity will bring the operational status to up."
    ::= { prvtEpsServiceEntry 20 }

prvtEpsServiceLastEvent OBJECT-TYPE
    SYNTAX      INTEGER { unknown(0), switchoverAlarm(1), 
                    lostCommunication(2), restoredCommunication(3), 
                    signalFailDetected(4), signalDegradeDetected(5), 
                    protctSignalFailDetected(6), signalFailRecovery(7), 
                    signalDegradeRecovery(8), 
                    protctSignalFailRecovery(9) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "The most recent event about which the application has sent a notification."
    ::= { prvtEpsServiceEntry 21 }

prvtEpsServicePrimaryStatus OBJECT-TYPE
    SYNTAX      INTEGER { psFailed(0), psOk(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Primary path state."
    ::= { prvtEpsServiceEntry 22 }

prvtEpsServiceSecondaryStatus OBJECT-TYPE
    SYNTAX      INTEGER { psFailed(0), psOk(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Secondary path state."
    ::= { prvtEpsServiceEntry 23 }

prvtEpsServiceRemoteState OBJECT-TYPE
    SYNTAX      PrvtEpsProtectionStateType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Protection state of the remote side."
    ::= { prvtEpsServiceEntry 24 }

prvtEpsServiceRemoteApsChannel OBJECT-TYPE
    SYNTAX      INTEGER { no(0), yes(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Active APS communication reported by the remote."
    ::= { prvtEpsServiceEntry 25 }

prvtEpsServiceRemoteProtection OBJECT-TYPE
    SYNTAX      INTEGER { pt1Plus1(0), pt1To1(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Type of protection (1+1 or 1:1) reported by the remote device."
    ::= { prvtEpsServiceEntry 26 }

prvtEpsServiceRemoteDirection OBJECT-TYPE
    SYNTAX      INTEGER { dtUnidirectional(0), dtBidirectional(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Type of protection (unidirectional or bidirectional) reported by the remote."
    ::= { prvtEpsServiceEntry 27 }

prvtEpsServiceRemoteRevertive OBJECT-TYPE
    SYNTAX      INTEGER { no(0), yes(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Protection type (revertive or non-revertive) reported by the remote."
    ::= { prvtEpsServiceEntry 28 }

prvtEpsServiceLocalApsChannel OBJECT-TYPE
    SYNTAX      INTEGER { no(0), yes(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Active APS communication reported by the remote."
    ::= { prvtEpsServiceEntry 29 }

prvtEpsServiceLocalProtection OBJECT-TYPE
    SYNTAX      INTEGER { pt1Plus1(0), pt1To1(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Type of protection (1+1 or 1:1) reported by the remote device."
    ::= { prvtEpsServiceEntry 30 }

prvtEpsServiceLocalDirection OBJECT-TYPE
    SYNTAX      INTEGER { dtUnidirectional(0), dtBidirectional(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Type of protection (unidirectional or bidirectional) reported by the remote."
    ::= { prvtEpsServiceEntry 31 }

prvtEpsServiceClear OBJECT-TYPE
    SYNTAX      PrvtEpsActionType
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Sends the Clear command to this EPS service."
    ::= { prvtEpsServiceEntry 32 }

prvtEpsServiceManualSwitch OBJECT-TYPE
    SYNTAX      PrvtEpsActionType
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Sends the Manual Switch command to this EPS service."
    ::= { prvtEpsServiceEntry 33 }

prvtEpsServiceForcedSwitch OBJECT-TYPE
    SYNTAX      PrvtEpsActionType
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Sends the Forced Switch command to this EPS service."
    ::= { prvtEpsServiceEntry 34 }

prvtEpsServiceLockout OBJECT-TYPE
    SYNTAX      PrvtEpsActionType
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "Sends the LockOut command to this EPS service."
    ::= { prvtEpsServiceEntry 35 }

prvtEpsServiceProtectionCounter OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Counts how many times the service has gone to Protection."
    ::= { prvtEpsServiceEntry 36 }

prvtEpsDefectAlarm NOTIFICATION-TYPE
    OBJECTS     { prvtEpsServiceOperationalStatus, 
                  prvtEpsServiceDefectsPresent }
    STATUS      current
    DESCRIPTION 
        "1. EPS service is either operational or not operational;
         2. Failure of protocol defects."
    ::= { prvtEpsMIBNotifications 1 }

prvtEpsSwitchoverAlarm NOTIFICATION-TYPE
    OBJECTS     { prvtEpsServiceActivePath }
    STATUS      current
    DESCRIPTION 
        "The alarm is issued if the active link is changed,
         pointing to the path where the switchover occured."
    ::= { prvtEpsMIBNotifications 2 }

prvtEpsLostCommunication NOTIFICATION-TYPE
    OBJECTS     { prvtEpsSvcId }
    STATUS      current
    DESCRIPTION 
        "The alarm is issued in case of non reception of APS frames
         in three consecutive intervals each representing 5 seconds."
    ::= { prvtEpsMIBNotifications 3 }

prvtEpsRestoredCommunication NOTIFICATION-TYPE
    OBJECTS     { prvtEpsSvcId }
    STATUS      current
    DESCRIPTION 
        "APS frames are received normally after APS communication failure."
    ::= { prvtEpsMIBNotifications 4 }

prvtEpsSignalFailDetected NOTIFICATION-TYPE
    OBJECTS     { prvtEpsSvcId }
    STATUS      current
    DESCRIPTION 
        "The alarm is issued in case of CCMs are not received
         and (3.5 * CCMtime(CCMinterval)) has expired."
    ::= { prvtEpsMIBNotifications 5 }

prvtEpsSignalDegradeDetected NOTIFICATION-TYPE
    OBJECTS     { prvtEpsSvcId }
    STATUS      current
    DESCRIPTION 
        "The alarm is issued in case of monitored error threshold is crossed:
         1W Jitter error,
         2W Jitter error,
         Latency error,
         Frame loss error."
    ::= { prvtEpsMIBNotifications 6 }

prvtEpsProtctSignalFailDetected NOTIFICATION-TYPE
    OBJECTS     { prvtEpsSvcId }
    STATUS      current
    DESCRIPTION 
        "The alarm is issued in case of CCMs are not received on the protected link
         and (3.5 * CCMtime(CCMinterval)) has expired or the protected link is down."
    ::= { prvtEpsMIBNotifications 7 }

prvtEpsSignalFailRecovery NOTIFICATION-TYPE
    OBJECTS     { prvtEpsSvcId }
    STATUS      current
    DESCRIPTION 
        "The alarm is issued in case of CCMs start to be received
         correctly again after a prvtEpsSignalFailDetected alarm occured
         and (3.5 * CCMtime(CCMinterval)) timer no longer expires or the link is up ."
    ::= { prvtEpsMIBNotifications 8 }

prvtEpsSignalDegradeRecovery NOTIFICATION-TYPE
    OBJECTS     { prvtEpsSvcId }
    STATUS      current
    DESCRIPTION 
        "The alarm is issued in case of monitored error threshold is crossed bellow limis:
         1W Jitter error,
         2W Jitter error,
         Latency error,
         Frame loss error."
    ::= { prvtEpsMIBNotifications 9 }

prvtEpsProtctSignalFailRecovery NOTIFICATION-TYPE
    OBJECTS     { prvtEpsSvcId }
    STATUS      current
    DESCRIPTION 
        "The alarm is issued in case of CCMs start to be received correctly again
         on the protected link after a prvtEpsProtctSignalFailDetected alarm occured
         and (3.5 * CCMtime(CCMinterval)) timer no longer expires or the link is up ."
    ::= { prvtEpsMIBNotifications 10 }

END -- end of module PRVT-EPS-MIB.