summaryrefslogtreecommitdiff
path: root/MIBS/telco-systems/binox/PRVT-ALARM-MIB
blob: 0d20e1aa585c79925d9185eef0508644df7e61a9 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-ALARM-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------

PRVT-ALARM-MIB DEFINITIONS ::= BEGIN

IMPORTS
    software
        FROM PRVT-SWITCH-MIB
    Counter32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, 
    Unsigned32
        FROM SNMPv2-SMI
    TEXTUAL-CONVENTION
        FROM SNMPv2-TC;

prvtAlarmMIB MODULE-IDENTITY
    LAST-UPDATED "201303250000Z"
    ORGANIZATION 
        "BATM Advanced Communication"
    CONTACT-INFO 
        "BATM/Telco Systems Support team
         Email:
         For North America: techsupport@telco.com
         For North Europe: support@batm.de, info@batm.de
         For the rest of the world: techsupport@telco.com"
    DESCRIPTION 
        "Information for current snmp allarms"
    REVISION    "201303250000Z"
    DESCRIPTION 
        "Initial implementation."
    ::= { software 4 }


prvtAlarmMIBObjects OBJECT IDENTIFIER
    ::= { prvtAlarmMIB 1 }

prvtUpdatedCurrentAlarmCounter OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Last updated alarm counter"
    ::= { prvtAlarmMIBObjects 1 }

prvtAlarmCurrentTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PrvtAlarmCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "This table contains current alarms."
    ::= { prvtAlarmMIBObjects 2 }

prvtAlarmCurrentEntry OBJECT-TYPE
    SYNTAX      PrvtAlarmCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "Entry in prvtAlarmCurrentTable containing the info of a 
         current RAISED trap."
    INDEX       { prvtAlarmCurrentCounter }
    ::= { prvtAlarmCurrentTable 1 }

PrvtAlarmCurrentEntry ::= SEQUENCE {
    prvtAlarmCurrentCounter         Counter32,
    prvtAlarmCurrentRaisedTime      Unsigned32,
    prvtAlarmCurrentSeverity        INTEGER,
    prvtAlarmCurrentDescription     OCTET STRING
}

prvtAlarmCurrentCounter OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "A running counter of open alarms, the counter
         is incremented on every new alarm. It is cleared after reset."
    ::= { prvtAlarmCurrentEntry 1 }

prvtAlarmCurrentRaisedTime OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "The raised time of this alarm.
         Time in seconds since January 1, 1970 00:00 UTC."
    ::= { prvtAlarmCurrentEntry 2 }

prvtAlarmCurrentSeverity OBJECT-TYPE
    SYNTAX      INTEGER { clear(0), event(1), warning(2), minor(3), 
                    major(4), critical(5), unknown(99) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "The current alarm severity"
    ::= { prvtAlarmCurrentEntry 3 }

prvtAlarmCurrentDescription OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "The alarm description."
    ::= { prvtAlarmCurrentEntry 4 }

END -- end of module PRVT-ALARM-MIB.