1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
3928
3929
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
3944
3945
3946
3947
3948
3949
3950
3951
3952
3953
3954
3955
3956
3957
3958
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
3981
3982
3983
3984
3985
3986
3987
3988
3989
3990
3991
3992
3993
3994
3995
3996
3997
3998
3999
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
4032
4033
4034
4035
4036
4037
4038
4039
4040
4041
4042
4043
4044
4045
4046
4047
4048
4049
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063
4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
4092
4093
4094
4095
4096
4097
4098
4099
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
4128
4129
4130
4131
4132
4133
4134
4135
4136
4137
4138
4139
4140
4141
4142
4143
4144
4145
4146
4147
4148
4149
4150
4151
4152
4153
4154
4155
4156
4157
4158
4159
4160
4161
4162
4163
4164
4165
4166
4167
4168
4169
4170
4171
4172
4173
4174
4175
4176
4177
4178
4179
4180
4181
4182
4183
4184
4185
4186
4187
4188
4189
4190
4191
4192
4193
4194
4195
4196
4197
4198
4199
4200
4201
4202
4203
4204
4205
4206
4207
4208
4209
4210
4211
4212
4213
4214
4215
4216
4217
4218
4219
4220
4221
4222
4223
4224
4225
4226
4227
4228
4229
4230
4231
4232
4233
4234
4235
4236
4237
4238
4239
4240
4241
4242
4243
4244
4245
4246
4247
4248
4249
4250
4251
4252
4253
4254
4255
4256
4257
4258
4259
4260
4261
4262
4263
4264
4265
4266
4267
4268
4269
4270
4271
4272
4273
4274
4275
4276
4277
4278
4279
4280
4281
4282
4283
4284
4285
4286
4287
4288
4289
4290
4291
4292
4293
4294
4295
4296
4297
4298
4299
4300
4301
4302
4303
4304
4305
4306
4307
4308
4309
4310
4311
4312
4313
4314
4315
4316
4317
4318
4319
4320
4321
4322
4323
4324
4325
4326
4327
4328
4329
4330
4331
4332
4333
4334
4335
4336
4337
4338
4339
4340
4341
4342
4343
4344
4345
4346
4347
4348
4349
4350
4351
4352
4353
4354
4355
4356
4357
4358
4359
4360
4361
4362
4363
4364
4365
4366
4367
4368
4369
4370
4371
4372
4373
4374
4375
4376
4377
4378
4379
4380
4381
4382
4383
4384
4385
4386
4387
4388
4389
4390
4391
4392
4393
4394
4395
4396
4397
4398
4399
4400
4401
4402
4403
4404
4405
4406
4407
4408
4409
4410
4411
4412
4413
4414
4415
4416
4417
4418
4419
4420
4421
4422
4423
4424
4425
4426
4427
4428
4429
4430
4431
4432
4433
4434
4435
4436
4437
4438
4439
4440
4441
4442
4443
4444
4445
4446
4447
4448
4449
4450
4451
4452
4453
4454
4455
4456
4457
4458
4459
4460
4461
4462
4463
4464
4465
4466
4467
4468
4469
4470
4471
4472
4473
4474
4475
4476
4477
4478
4479
4480
4481
4482
4483
4484
4485
4486
4487
4488
4489
4490
4491
4492
4493
4494
4495
4496
4497
4498
4499
4500
4501
4502
4503
4504
4505
4506
4507
4508
4509
4510
4511
4512
4513
4514
4515
4516
4517
4518
4519
4520
4521
4522
4523
4524
4525
4526
4527
4528
4529
4530
4531
4532
4533
4534
4535
4536
4537
4538
4539
4540
4541
4542
4543
4544
4545
4546
4547
4548
4549
4550
4551
4552
4553
4554
4555
4556
4557
4558
4559
4560
4561
4562
4563
4564
4565
4566
4567
4568
4569
4570
4571
4572
4573
4574
4575
4576
4577
4578
4579
4580
4581
4582
4583
4584
4585
4586
4587
4588
4589
4590
4591
4592
4593
4594
4595
4596
4597
4598
4599
4600
4601
4602
4603
4604
4605
4606
4607
4608
4609
4610
4611
4612
4613
4614
4615
4616
4617
4618
4619
4620
4621
4622
4623
4624
4625
4626
4627
4628
4629
4630
4631
4632
4633
4634
4635
4636
4637
4638
4639
4640
4641
4642
4643
4644
4645
4646
4647
4648
4649
4650
4651
4652
4653
4654
4655
4656
4657
4658
4659
4660
4661
4662
4663
4664
4665
4666
4667
4668
4669
4670
4671
4672
4673
4674
4675
4676
4677
4678
4679
4680
4681
4682
4683
4684
4685
4686
4687
4688
4689
4690
4691
4692
4693
4694
4695
4696
4697
4698
4699
4700
4701
4702
4703
4704
4705
4706
4707
4708
4709
4710
4711
4712
4713
4714
4715
4716
4717
4718
4719
4720
4721
4722
4723
4724
4725
4726
4727
4728
4729
4730
4731
4732
4733
4734
4735
4736
4737
4738
4739
4740
4741
4742
4743
4744
4745
4746
4747
4748
4749
4750
4751
4752
4753
4754
4755
4756
4757
4758
4759
4760
4761
4762
4763
4764
4765
4766
4767
4768
4769
4770
4771
4772
4773
4774
4775
4776
4777
4778
4779
4780
4781
4782
4783
4784
4785
4786
4787
4788
4789
4790
4791
4792
4793
4794
4795
4796
4797
4798
4799
4800
4801
4802
4803
4804
4805
4806
4807
4808
4809
4810
4811
4812
4813
4814
4815
4816
4817
4818
4819
4820
4821
4822
4823
4824
4825
4826
4827
4828
4829
4830
4831
4832
4833
4834
4835
4836
4837
4838
4839
4840
4841
4842
4843
4844
4845
4846
4847
4848
4849
4850
4851
4852
4853
4854
4855
4856
4857
4858
4859
4860
4861
4862
4863
4864
4865
4866
4867
4868
4869
4870
4871
4872
4873
4874
4875
4876
4877
4878
4879
4880
4881
4882
4883
4884
4885
4886
4887
4888
4889
4890
4891
4892
4893
4894
4895
4896
4897
4898
4899
4900
4901
4902
4903
4904
4905
4906
4907
4908
4909
4910
4911
4912
4913
4914
4915
4916
4917
4918
4919
4920
4921
4922
4923
4924
4925
4926
4927
4928
4929
4930
4931
4932
4933
4934
4935
4936
4937
4938
4939
4940
4941
4942
4943
4944
4945
4946
4947
4948
4949
4950
4951
4952
4953
4954
4955
4956
4957
4958
4959
4960
4961
4962
4963
4964
4965
4966
4967
4968
4969
4970
4971
4972
4973
4974
4975
4976
4977
4978
4979
4980
4981
4982
4983
4984
4985
4986
4987
4988
4989
4990
4991
4992
4993
4994
4995
4996
4997
4998
4999
5000
5001
5002
5003
5004
5005
5006
5007
5008
5009
5010
5011
5012
5013
5014
5015
5016
5017
5018
5019
5020
5021
5022
5023
5024
5025
5026
5027
5028
5029
5030
5031
5032
5033
5034
5035
5036
5037
5038
5039
5040
5041
5042
5043
5044
5045
5046
5047
5048
5049
5050
5051
5052
5053
5054
5055
5056
5057
5058
5059
5060
5061
5062
5063
5064
5065
5066
5067
5068
5069
5070
5071
5072
5073
5074
5075
5076
5077
5078
5079
5080
5081
5082
5083
5084
5085
5086
5087
5088
5089
5090
5091
5092
5093
5094
5095
5096
5097
5098
5099
5100
5101
5102
5103
5104
5105
5106
5107
5108
5109
5110
5111
5112
5113
5114
5115
5116
5117
5118
5119
5120
5121
5122
5123
5124
5125
5126
5127
5128
5129
5130
5131
5132
5133
5134
5135
5136
5137
5138
5139
5140
5141
5142
5143
5144
5145
5146
5147
5148
5149
5150
5151
5152
5153
5154
5155
5156
5157
5158
5159
5160
5161
5162
5163
5164
5165
5166
5167
5168
5169
5170
5171
5172
5173
5174
5175
5176
5177
5178
5179
5180
5181
5182
5183
5184
5185
5186
5187
5188
5189
5190
5191
5192
5193
5194
5195
5196
5197
5198
5199
5200
5201
5202
5203
5204
5205
5206
5207
5208
5209
5210
5211
5212
5213
5214
5215
5216
5217
5218
5219
5220
5221
5222
5223
5224
5225
5226
5227
5228
5229
5230
5231
5232
5233
5234
|
-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-MPLS-TE-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
PRVT-MPLS-TE-MIB DEFINITIONS ::= BEGIN
-- PRODUCT-SHORT-NAME MPLS
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32, Unsigned32, Counter32, zeroDotZero,
Counter64, TimeTicks
FROM SNMPv2-SMI
NOTIFICATION-TYPE, transmission
FROM SNMPv2-SMI -- [RFC2578]
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
TEXTUAL-CONVENTION, TruthValue, RowStatus, RowPointer,
StorageType, DisplayString, TimeStamp
FROM SNMPv2-TC
InterfaceIndexOrZero
FROM IF-MIB
MplsBitRate, MplsBurstSize, MplsLSPID,
MplsTunnelIndex, MplsTunnelInstanceIndex,
MplsTunnelAffinity, MplsExtendedTunnelId, MplsPathIndex,
MplsPathIndexOrZero, MplsOwner, TeHopAddressType,
TeHopAddress, TeHopAddressAS, TeHopAddressUnnum
FROM MPLS-TC-PRIV-STDEXT-MIB -- [RFC3811]
InetAddressPrefixLength, InetAddressType, InetAddress, InetAddressIPv4
FROM INET-ADDRESS-MIB -- [RFC3291]
prvtMplsTeMibEntityIndex
FROM PRVT-TEMIB-ENTITY-MIB
mpls FROM PRVT-CR-LDP-MIB;
mplsTeMIB MODULE-IDENTITY
LAST-UPDATED "200902170000Z"
ORGANIZATION "BATM Advanced Communication"
CONTACT-INFO
" BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"This MIB module contains managed object definitions
for MPLS Traffic Engineering (TE) as defined in:
Extensions to RSVP for LSP Tunnels, Awduche et al,
Internet Draft <draft-ietf-mpls-rsvp-lsp-tunnel-
07.txt>, August 2000; Constraint-Based LSP Setup
using LDP, B. Jamoussi, Internet Draft <draft-ietf-
mpls-cr-ldp-04.txt>, July 2000; Requirements for
Traffic Engineering Over MPLS, Awduche, D., J.
Malcolm, J., Agogbua, J., O'Dell, M., J. McManus,
<rfc2702.txt>, September 1999."
-- Revision history.
REVISION "200902170000Z"
DESCRIPTION
"Removed references to undefined OBJECT-GROUPs."
REVISION "200811200000Z"
DESCRIPTION
"Added additional timer (mplsTunnelMBBTimeOut) in the tunnel mib."
REVISION "200808280000Z"
DESCRIPTION
"mplsTunnelReoptimized notification updates."
REVISION "200803030000Z"
DESCRIPTION
"mplsTunnelRebuildTimer updates."
REVISION "200712060000Z"
DESCRIPTION
"Minor TC updates."
REVISION "200712020959Z"
DESCRIPTION
"The attribute for guarded destination has IPv4 TC."
::= { mpls 2 }
-- Textual Conventions.
MplsTunnelIndexSyntax ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Index into mplsTunnelTable."
SYNTAX Integer32 (0..65535)
MplsLsrId ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A unique identifier for an MPLS LSR. This MAY
represent an IpV4 address."
SYNTAX Unsigned32
MplsGeneralizedLabelType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The label types that are defined for Generalized
MPLS."
SYNTAX INTEGER {
mplsLabel(1),
generalizedLabel(2),
wavebandLabel(3)
}
-- Addition
MplsTunnelPrivateDataSyntax ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents private data field."
SYNTAX OCTET STRING (SIZE (0..8))
MplsTunnelTNAAddress ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"TNA address of a tunnel."
SYNTAX OCTET STRING (SIZE (0..20))
MplsGeneralizedLabel ::= TEXTUAL-CONVENTION
DISPLAY-HINT "255x"
STATUS current
DESCRIPTION
"This value represents a generalized MPLS Label.
The label contents are specific to the label being
represented.
Wherever an MplsGeneralizedLabel is copied to or from
a signaling protocol message, it is copied byte for
byte as is. Therefore, if the octet string is
intended to represent multibyte values, it encodes
those values in network (big-endian) byte order.
This interpretation applies in particular to the
non-generalized MPLS labels (32 bits) used in ATM, FR
and generic MPLS networks."
SYNTAX OCTET STRING (SIZE (0..255))
-- End Addition
-- Top level components of this MIB.
-- tables, scalars
mplsTeObjects OBJECT IDENTIFIER ::= { mplsTeMIB 1 }
-- traps
mplsTeNotifications OBJECT IDENTIFIER ::= { mplsTeMIB 2 }
mplsTeNotifyPrefix OBJECT IDENTIFIER ::= { mplsTeNotifications 0 }
-- conformance
mplsTeConformance OBJECT IDENTIFIER ::= { mplsTeMIB 3 }
-- MPLS tunnel table.
-- Addition
mplsTunnelIndexNextTable OBJECT-TYPE
-- FAMILY-SHORT-NAME MPLS_TNI
SYNTAX SEQUENCE OF MplsTunnelIndexNextEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the next available values of
mplsTunnelIndex for all entities."
::= { mplsTeObjects 1 }
mplsTunnelIndexNextEntry OBJECT-TYPE
SYNTAX MplsTunnelIndexNextEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents the next available
mplsTunnelIndex for a specific TE-MIB entity.
This MIB table is indexed by the PRVT-TE-MIB entity Index."
INDEX { prvtMplsTeMibEntityIndex }
::= { mplsTunnelIndexNextTable 1 }
MplsTunnelIndexNextEntry ::= SEQUENCE {
mplsTunnelIndexNextIndex Integer32
}
-- End Addition
mplsTunnelIndexNextIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the next appropriate value
to be used for mplsTunnelIndex when creating
entries in the mplsTunnelTable. If the number of
unassigned entries is exhausted, this object
will take on the value of 0. To obtain the
mplsTunnelIndex value for a new entry, the
manager must first issue a management protocol
retrieval operation to obtain the current value
of this object. The agent should modify the
value to reflect the next unassigned index after
each retrieval operation. After a manager
retrieves a value the agent will determine
through its local policy when this index value
will be made available for reuse."
::= { mplsTunnelIndexNextEntry 1 }
mplsTunnelTable OBJECT-TYPE
-- FAMILY-SHORT-NAME MPLS_TNNL
SYNTAX SEQUENCE OF MplsTunnelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTunnelTable allows new MPLS tunnels to be
created between an LSR and a remote endpoint, and
existing tunnels to be reconfigured or removed.
Note that only point-to-point tunnel segments are
supported, although multi-point-to-point and point-
to-multi-point connections are supported by an LSR
acting as a cross-connect. Each MPLS tunnel can
thus have one out-segment originating at this LSR
and/or one in-segment terminating at this LSR.
To configure tunnels where the ingress and egress routers
are identified by IPv6 addresses, the following approach is
used.
- The mplsTunnelIngressLSRId and mplsTunnelEgressLSRId
fields are set to 32-bit identifiers for the ingress and
egress routers.
- mplsTunnelHopTableIndex must be set to a non-zero value.
- The first hop in the hop table for the tunnel path must be
set to a global scope IPv6 address of the local router.
- The last entry in the hop table must be set to a global
scope IPv6 address of the egress router."
::= { mplsTeObjects 2 }
mplsTunnelEntry OBJECT-TYPE
SYNTAX MplsTunnelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents an MPLS tunnel.
An entry can be created by a network administrator
or by an SNMP agent as instructed by an MPLS
signaling protocol. Whenever a new entry is created
with mplsTunnelIsIf set to true(1), then a
corresponding entry is created in ifTable as well
(see RFC 2233). The ifType of this entry is
mplsTunnel(150)."
INDEX { prvtMplsTeMibEntityIndex,
mplsTunnelIndex, mplsTunnelInstance,
mplsTunnelIngressLSRId, mplsTunnelEgressLSRId }
::= { mplsTunnelTable 1 }
MplsTunnelEntry ::= SEQUENCE {
mplsTunnelIndex MplsTunnelIndexSyntax,
mplsTunnelInstance MplsTunnelInstanceIndex,
mplsTunnelIngressLSRId MplsExtendedTunnelId,
mplsTunnelEgressLSRId MplsExtendedTunnelId,
mplsTunnelName DisplayString,
mplsTunnelDescr DisplayString,
mplsTunnelIsIf TruthValue,
mplsTunnelIfIndex InterfaceIndexOrZero,
mplsTunnelOwner MplsOwner,
mplsTunnelRole INTEGER,
mplsTunnelXCPointer RowPointer,
mplsTunnelSignallingProto INTEGER,
mplsTunnelSetupPrio Integer32,
mplsTunnelHoldingPrio Integer32,
mplsTunnelSessionAttributes BITS,
mplsTunnelLocalProtectInUse TruthValue,
mplsTunnelResourcePointer RowPointer,
mplsTunnelPrimaryInstance MplsTunnelInstanceIndex,
mplsTunnelInstancePriority Unsigned32,
mplsTunnelHopTableIndex MplsPathIndexOrZero,
mplsTunnelPathInUse MplsPathIndexOrZero,
mplsTunnelARHopTableIndex MplsPathIndexOrZero,
mplsTunnelCHopTableIndex MplsPathIndexOrZero,
mplsTunnelIncludeAnyAffinity MplsTunnelAffinity,
mplsTunnelIncludeAllAffinity MplsTunnelAffinity,
mplsTunnelExcludeAnyAffinity MplsTunnelAffinity,
mplsTunnelTotalUpTime TimeTicks,
mplsTunnelInstanceUpTime TimeTicks,
mplsTunnelPrimaryUpTime TimeTicks,
mplsTunnelPathChanges Counter32,
mplsTunnelLastPathChange TimeTicks,
mplsTunnelCreationTime TimeStamp,
mplsTunnelStateTransitions Counter32,
mplsTunnelAdminStatus INTEGER,
mplsTunnelOperStatus INTEGER,
mplsTunnelRowStatus RowStatus,
mplsTunnelStorageType StorageType,
-- Addition
mplsTunnelUnnumIf TruthValue,
mplsTunnelAttributes BITS,
mplsTunnelLSPEncoding INTEGER,
mplsTunnelSwitchingType Unsigned32,
mplsTunnelLinkProtection BITS,
mplsTunnelGPid INTEGER,
mplsTunnelSecondary TruthValue,
mplsTunnelDirection INTEGER,
mplsTunnelPathComp INTEGER,
mplsTunnelUpNotRecipType InetAddressType,
mplsTunnelUpNotRecip InetAddress,
mplsTunnelDownNotRecipType InetAddressType,
mplsTunnelDownNotRecip InetAddress,
mplsTunnelAdminStatusFlags BITS,
mplsTunnelExtraParamsPtr RowPointer,
mplsTunnelUseEgressLabel TruthValue,
mplsTunnelEgressLabel MplsGeneralizedLabel,
mplsTunnelEgressLabelType MplsGeneralizedLabelType,
mplsTunnelOmitEROIfOneHop TruthValue,
mplsTunnelPrivateData MplsTunnelPrivateDataSyntax,
mplsTunnelSrcTNAAddressType INTEGER,
mplsTunnelSrcTNAAddress MplsTunnelTNAAddress,
mplsTunnelDestTNAAddressType INTEGER,
mplsTunnelDestTNAAddress MplsTunnelTNAAddress,
mplsTunnelEndToEndRerouting TruthValue,
mplsTunnelIsUni TruthValue,
mplsTunnelUniServiceLevel Integer32,
mplsTunnelUniEgressLabel MplsGeneralizedLabel,
mplsTunnelUniEgressLabelType MplsGeneralizedLabelType,
mplsTunnelUniEgressLabelPort Unsigned32,
mplsTunnelUniRvsEgressLabel MplsGeneralizedLabel,
mplsTunnelUniRvsEgressLabelType MplsGeneralizedLabelType,
mplsTunnelUniRvsEgressLabelPort Unsigned32,
mplsTunnelDeletionMode INTEGER,
mplsTunnelUniDiversityListIndex Integer32,
mplsTunnelDiffServIndex Integer32,
mplsTunnelReversePrivateData MplsTunnelPrivateDataSyntax,
mplsTunnelFastRerouteMode INTEGER,
mplsTunnelBackupSetupPrio Integer32,
mplsTunnelBackupHoldingPriority Integer32,
mplsTunnelBackupIncAny MplsTunnelAffinity,
mplsTunnelBackupIncAll MplsTunnelAffinity,
mplsTunnelBackupExcAny MplsTunnelAffinity,
mplsTunnelBackupBandwidth MplsBitRate,
mplsTunnelBackupMaxHops Unsigned32,
mplsTunnelIsSpc TruthValue,
mplsTunnelUniIngressLabel MplsGeneralizedLabel,
mplsTunnelUniIngressLabelType MplsGeneralizedLabelType,
mplsTunnelUniIngressLabelPort Unsigned32,
mplsTunnelUniRvsIngrLabel MplsGeneralizedLabel,
mplsTunnelUniRvsIngrLabelType MplsGeneralizedLabelType,
mplsTunnelUniRvsIngrLabelPort Unsigned32,
mplsTunnelDiffServClassType Integer32,
mplsTunnelExtendedProtection TruthValue,
mplsTunnelProtecting TruthValue,
mplsTunnelNotification TruthValue,
mplsTunnelLspProtection Unsigned32,
mplsTunnelAssociatedLspId MplsTunnelInstanceIndex,
mplsTunnelCallIdType INTEGER,
mplsTunnelCallId OCTET STRING,
mplsTunnelIsIpv6 TruthValue,
mplsTunnelMtu Integer32,
mplsTunnelRebuildTimer TimeTicks,
mplsTunnelOperStatusFlags BITS,
mplsTunnelGuardedDest InetAddressIPv4,
mplsTunnelMBBTimeOut Integer32
-- End Addition
}
mplsTunnelIndex OBJECT-TYPE
SYNTAX MplsTunnelIndexSyntax
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies this row."
::= { mplsTunnelEntry 1 }
mplsTunnelInstance OBJECT-TYPE
SYNTAX MplsTunnelInstanceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies an instance of a tunnel. It is
useful to identify multiple instances of tunnels
for the purposes of backup and parallel tunnels."
::= { mplsTunnelEntry 2 }
mplsTunnelIngressLSRId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identity of the ingress LSR associated with this
tunnel instance. When the MPLS signalling protocol
is rsvp(2) this value SHOULD be equal to the Tunnel
Sender Address in the Sender Template object and MAY
be equal to the Extended Tunnel Id field in the
SESSION object. When the MPLS signalling protocol is
crldp(3) this value SHOULD be equal to the Ingress
LSR Router ID field in the LSPID TLV object."
REFERENCE
"1. RSVP-TE: Extensions to RSVP for LSP Tunnels,
Awduche et al, RFC 3209, December 2001
2. Constraint-Based LSP Setup using LDP, Jamoussi
(Editor), RFC 3212, January 2002"
::= { mplsTunnelEntry 3 }
mplsTunnelEgressLSRId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identity of the egress LSR associated with this
tunnel instance."
::= { mplsTunnelEntry 4 }
mplsTunnelName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The canonical name assigned to the tunnel. This name
can be used to refer to the tunnel on the LSRs
console port. If mplsTunnelIsIf is set to true
then the ifName of the interface corresponding to
this tunnel should have a value equal to
mplsTunnelName. Also see the description of ifName
in RFC 2863."
REFERENCE
"RFC 2863 - The Interfaces Group MIB, McCloghrie, K.,
and F. Kastenholtz, June 2000"
::= { mplsTunnelEntry 5 }
mplsTunnelDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A textual string containing information about the
tunnel. If there is no description this object
contains a zero length string. This object is may
not be signaled by MPLS signaling protocols,
consequentally the value of this object at transit
and egress LSRs MAY be automatically generated or
absent."
::= { mplsTunnelEntry 6 }
mplsTunnelIsIf OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes whether or not this tunnel corresponds to an
interface represented in the interfaces group
table. Note that if this variable is set to true
then the ifName of the interface corresponding to
this tunnel should have a value equal to
mplsTunnelName. Also see the description of ifName
in RFC 2233."
DEFVAL { false }
::= { mplsTunnelEntry 7 }
mplsTunnelIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
-- Addition
-- MAX-ACCESS read-only
MAX-ACCESS read-create
-- End Addition
STATUS current
DESCRIPTION
"If mplsTunnelIsIf is set to true, then this value
contains the LSR-assigned ifIndex which corresponds
to an entry in the interfaces table. Otherwise
this variable should contain the value of zero
indicating that a valid ifIndex was not assigned to
this tunnel interface."
REFERENCE
"RFC 2863 - The Interfaces Group MIB, McCloghrie, K.,
and F. Kastenholtz, June 2000"
DEFVAL { 0 }
::= { mplsTunnelEntry 8 }
mplsTunnelOwner OBJECT-TYPE
SYNTAX MplsOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Denotes the entity that created and is responsible
for managing this tunnel. This column is
automatically filled by the agent on creation of a
row."
::= { mplsTunnelEntry 9 }
mplsTunnelRole OBJECT-TYPE
SYNTAX INTEGER { head(1),
transit(2),
tail(3),
headTail(4) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value signifies the role that this tunnel
entry/instance represents. This value MUST be set
to head(1) at the originating point of the tunnel.
This value MUST be set to transit(2) at transit
points along the tunnel, if transit points are
supported. This value MUST be set to tail(3) at the
terminating point of the tunnel if tunnel tails are
supported.
The value headTail(4) is provided for tunnels that
begin and end on the same LSR."
DEFVAL { head }
::= { mplsTunnelEntry 10 }
mplsTunnelXCPointer OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable points to a row in the mplsXCTable.
This table identifies the segments that compose
this tunnel, their characteristics, and
relationships to each other. A value of zeroDotZero
indicates that no LSP has been associated with this
tunnel yet.
The array of longs specified here is configured as
the OID array for the lmgr entity cross connect row.
This consists of the length, family, lmgr entity
index and row index values. Only the
AMB_MPLS_XC_INDEX_IDX index is referenced by the
TE-MIB."
REFERENCE
"Srinivasan, C., Viswanathan, A., and T. Nadeau,
Multiprotocol Label Switching (MPLS) Label Switching
Router (LSR) Management Information Base (MIB), RFC 3813,
June 2004"
DEFVAL { zeroDotZero }
::= { mplsTunnelEntry 11 }
mplsTunnelSignallingProto OBJECT-TYPE
SYNTAX INTEGER {
none(1),
rsvp(2),
crldp(3),
other(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The signalling protocol, if any, used to setup this
tunnel."
DEFVAL { none }
::= { mplsTunnelEntry 12 }
mplsTunnelSetupPrio OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the setup priority of this tunnel."
REFERENCE
"1. RSVP-TE: Extensions to RSVP for LSP Tunnels,
Awduche et al, RFC 3209, December 2001
2. Constraint-Based LSP Setup using LDP, Jamoussi
(Editor), RFC 3212, January 2002"
DEFVAL { 0 }
::= { mplsTunnelEntry 13 }
mplsTunnelHoldingPrio OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the holding priority for this tunnel."
REFERENCE
"1. RSVP-TE: Extensions to RSVP for LSP Tunnels,
Awduche et al, RFC 3209, December 2001
2. Constraint-Based LSP Setup using LDP, Jamoussi
(Editor), RFC 3212, January 2002"
DEFVAL { 0 }
::= { mplsTunnelEntry 14 }
mplsTunnelSessionAttributes OBJECT-TYPE
SYNTAX BITS {
fastReroute (0),
mergingPermitted (1),
isPersistent (2),
isPinned (3),
recordRoute(4),
-- Addition
reserved5(5),
bandwidthProtect(6),
nodeProtect(7)
-- End Addition
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This bitmask indicates optional session values for
this tunnel. The following describes these bit
fields:
fastReroute This flag indicates that any tunnel
hop may choose to reroute this tunnel without
tearing it down. This flag permits transit routers
to use a local repair mechanism which may result in
violation of the explicit routing of this tunnel.
When a fault is detected on an adjacent downstream
link or node, a transit router can reroute traffic
for fast service restoration.
mergingPermitted This flag permits transit routers
to merge this session with other RSVP sessions for
the purpose of reducing resource overhead on
downstream transit routers, thereby providing
better network scalability.
isPersistent Indicates whether this tunnel should
be restored automatically after a failure occurs.
isPinned This flag indicates whether the loose-
routed hops of this tunnel are to be pinned.
recordRoute This flag indicates if the
signaling protocol should remember the tunnel path
after it has been signaled.
-- recordLabels This flag indicates if the
-- signaling protocol should record labels as well as
-- the tunnel path.
bandwidthProtect This flag indicates whether fast reroute
bandwidth protection is desired.
nodeProtect This flag indicates whether fast reroute
node protection is desired."
REFERENCE
"1. RSVP-TE: Extensions to RSVP for LSP Tunnels,
Awduche et al, RFC 3209, December 2001."
DEFVAL { {} }
::= { mplsTunnelEntry 15 }
mplsTunnelLocalProtectInUse OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates that the local repair mechanism is in use
to maintain this tunnel (usually in the face of an
outage of the link it was previously routed over)."
DEFVAL { false }
::= { mplsTunnelEntry 16 }
mplsTunnelResourcePointer OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable represents a pointer to the traffic
parameter specification for this tunnel. This
value may point at an entry in the
mplsTunnelResourceEntry to indicate which
mplsTunnelResourceEntry is to be assigned to this
LSP instance. This value may optionally point at
an externally defined traffic parameter
specification table. A value of zeroDotZero
indicates best-effort treatment. By having the
same value of this object, two or more LSPs can
indicate resource sharing.
In this implementation of the mplsTunnelTable, the row must either
be set to zeroDotZero, or must point at an entry in the
mplsTunnelResourceTable.
If a value other than zeroDotZero is used, then
mplsTunnelExtraParamsPtr must be set to zeroDotZero."
::= { mplsTunnelEntry 17 }
mplsTunnelPrimaryInstance OBJECT-TYPE
SYNTAX MplsTunnelInstanceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the instance index of the primary instance
of this tunnel."
DEFVAL { 0 }
::= { mplsTunnelEntry 18 }
mplsTunnelInstancePriority OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value indicates which priority, in descending
order, with 0 indicating the lowest priority,
within a group of tunnel instances. A group of
tunnel instances is defined as a set of LSPs with
the same mplsTunnelIndex in this table, but with a
different mplsTunnelInstance. Tunnel instance
priorities are used to denote the priority at which
a particular tunnel instance will supercede
another. Instances of tunnels containing the same
mplsTunnelInstancePriority will be used for load
sharing."
DEFVAL { 0 }
::= { mplsTunnelEntry 19 }
mplsTunnelHopTableIndex OBJECT-TYPE
SYNTAX MplsPathIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index into the mplsTunnelHopTable entry that
specifies the explicit route hops for this tunnel.
This object is meaningful only at the head-end of
the tunnel.
For UNI tunnels, this field should be set to 0.
For tunnels with no configured explicit route hops, this
field should be set to 0. In this case, the tunnel is
routed using mplsTunnelEgressLSRId."
DEFVAL { 0 }
::= { mplsTunnelEntry 20 }
mplsTunnelPathInUse OBJECT-TYPE
SYNTAX MplsPathIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value denotes the configured path that was
chosen for this tunnel. This value reflects the
secondary index into mplsTunnelHopTable. This path
may not exactly match the one in
mplsTunnelARHopTable due to the fact that some CSPF
modification may have taken place. See
mplsTunnelARHopTable for the actual path being
taken by the tunnel. A value of zero denotes that
no path is currently in use or available.
For UNI tunnels, this field should be set to 0.
For tunnels with no configued explicit route hops,
this field should be set to 0."
DEFVAL { 0 }
::= { mplsTunnelEntry 21 }
mplsTunnelARHopTableIndex OBJECT-TYPE
SYNTAX MplsPathIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index into the mplsTunnelARHopTable entry that
specifies the actual hops traversed by the tunnel.
This is automatically updated by the agent when the
actual hops becomes available."
DEFVAL { 0 }
::= { mplsTunnelEntry 22 }
mplsTunnelCHopTableIndex OBJECT-TYPE
SYNTAX MplsPathIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index into the mplsTunnelCHopTable entry that
specifies the computed hops traversed by the
tunnel. This is automatically updated by the agent
when computed hops become available or when
computed hops get modified."
DEFVAL { 0 }
::= { mplsTunnelEntry 23 }
mplsTunnelIncludeAnyAffinity OBJECT-TYPE
SYNTAX MplsTunnelAffinity
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A link satisfies the include-any constraint if and
only if the constraint is zero, or the link and the
constraint have a resource class in common.
The field is a bitmask. Every request does not overwrite
the previous one. 0 value resets the field.
"
REFERENCE
"1. RSVP-TE: Extensions to RSVP for LSP Tunnels,
Awduche et al, RFC 3209, December 2001."
DEFVAL { 0 }
::= { mplsTunnelEntry 24 }
mplsTunnelIncludeAllAffinity OBJECT-TYPE
SYNTAX MplsTunnelAffinity
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A link satisfies the include-all constraint if and
only if the link contains all of the administrative
groups specified in the constraint.
The field is a bitmask. Every request does not overwrite
the previous one. 0 value resets the field.
"
REFERENCE
"1. RSVP-TE: Extensions to RSVP for LSP Tunnels,
Awduche et al, RFC 3209, December 2001."
DEFVAL { 0 }
::= { mplsTunnelEntry 25 }
mplsTunnelExcludeAnyAffinity OBJECT-TYPE
SYNTAX MplsTunnelAffinity
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A link satisfies the exclude-any constraint if and
only if the link contains none of the
administrative groups specified in the constraint.
The field is a bitmask. Every request does not overwrite
the previous one. 0 value resets the field.
"
REFERENCE
"1. RSVP-TE: Extensions to RSVP for LSP Tunnels,
Awduche et al, RFC 3209, December 2001."
DEFVAL { 0 }
::= { mplsTunnelEntry 26 }
mplsTunnelTotalUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value represents the aggregate up time for all
instances of this tunnel, if available. If this
value is unavailable, it MUST return a value of 0."
DEFVAL { 0 }
::= { mplsTunnelEntry 27 }
mplsTunnelInstanceUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value identifies the total time that this
tunnel instance's operStatus has been Up(1)."
DEFVAL { 0 }
::= { mplsTunnelEntry 28 }
mplsTunnelPrimaryUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the total time the primary instance of
this tunnel has been active. The primary instance
of this tunnel is defined in
mplsTunnelPrimaryInstance."
::= { mplsTunnelEntry 29 }
mplsTunnelPathChanges OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the number of times the actual path for
this tunnel instance has changed."
::= { mplsTunnelEntry 30 }
mplsTunnelLastPathChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the time since the last change to the
actual path for this tunnel instance."
::= { mplsTunnelEntry 31 }
mplsTunnelCreationTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the value of SysUpTime when the first
instance of this tunnel came into existence.
That is, when the value of mplsTunnelOperStatus
was first set to up(1)."
::= { mplsTunnelEntry 32 }
mplsTunnelStateTransitions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the number of times the state
(mplsTunnelOperStatus) of this tunnel instance has
changed."
::= { mplsTunnelEntry 33 }
mplsTunnelAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
-- ready to pass packets
up(1),
down(2),
-- in some test mode
testing(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the desired operational status of this
tunnel."
::= { mplsTunnelEntry 34 }
mplsTunnelOperStatus OBJECT-TYPE
SYNTAX INTEGER {
-- ready to pass packets
up(1),
down(2),
-- in some test mode
testing(3),
-- status cannot be determined
unknown(4),
dormant(5),
-- some component is missing
notPresent(6),
-- down due to the state of
-- lower layer interfaces
lowerLayerDown(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the actual operational status of this
tunnel, which is typically but not limited to, a
function of the state of individual segments of
this tunnel."
::= { mplsTunnelEntry 35 }
mplsTunnelRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable is used to create, modify, and/or
delete a row in this table. When a row in this
table is in active(1) state, no objects in that row
can be modified by the agent except
mplsTunnelAdminStatus, mplsTunnelRowStatus and
mplsTunnelStorageType."
::= { mplsTunnelEntry 36 }
mplsTunnelStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The storage type for this tunnel entry.
Conceptual rows having the value 'permanent'
need not allow write-access to any columnar
objects in the row."
DEFVAL { volatile }
::= { mplsTunnelEntry 37 }
-- Addition
mplsTunnelUnnumIf OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes whether or not this tunnel corresponds to an unnumbered
interface represented in the interfaces group table.
This object is only used if mplsTunnelIsIf is set to 'true'.
If both this object and the mplsTunnelIsIf object are set to
'true', the originating LSR adds an LSP_TUNNEL_INTERFACE_ID
object to the outgoing Path message.
This object contains information that is only used by the
terminating LSR."
REFERENCE
"Signalling Unnumbered Links in RSVP-TE, Kompella, K.
and Rekhter, Y., RFC 3477, January 2003."
DEFVAL { false }
::= { mplsTunnelEntry 38 }
mplsTunnelAttributes OBJECT-TYPE
SYNTAX BITS {
reserved0(0),
reserved1(1),
reserved2(2),
reserved3(3),
reserved4(4),
labelRecordingDesired (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This bitmask indicates optional parameters for this tunnel.
These bits should be taken in addition to those defined in
mplsTunnelSessionAttributes in order to determine the full set
of options to be signaled (for example SESSION_ATTRIBUTES flags
in RSVP-TE). The following describes these bitfields:
labelRecordingDesired
This flag indicates that label information should be included
when doing a route record. This bit is not valid unless the
recordRoute bit is set in the mplsTunnelSessionAttributes object."
REFERENCE
"RSVP-TE: Extensions to RSVP for LSP Tunnels, Awduche et al.,
RFC 3209, December 2001."
DEFVAL { { } }
::= { mplsTunnelEntry 39 }
mplsTunnelLSPEncoding OBJECT-TYPE
SYNTAX INTEGER {
notInUse (0),
tunnelLspPacket (1),
tunnelLspEthernet (2),
tunnelLspAnsiEtsiPdh (3),
tunnelLspSdhSonet (5),
tunnelLspDigitalWrapper (7),
tunnelLspLambda (8),
tunnelLspFiber (9),
tunnelLspFiberChannel (11)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the encoding of the LSP being requested.
It is only required when a generalized label request will be used
for this LSP. A value of 0 in this object indicates that a
generalized label request will not be used to set up this LSP.
If this object indicates Sonet / SDH LSP encoding, then
the choice of QOS to use is controlled by the
mplsTunnelResourcePointer object. If
mplsTunnelResourcePointer is 0.0, then a Sonet/SDH QOS
format is used, else an Intserv QOS is used."
DEFVAL { notInUse }
::= { mplsTunnelEntry 40 }
mplsTunnelSwitchingType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the type of switching that should be performed on
a particular link. This field is needed for links that
advertise more than one type of switching capability.
Values of this field are as in the Switching Capability
field defined in rfc3471.
It is only used when mplsTunnelLSPEncoding is non-zero."
DEFVAL { 0 }
::= { mplsTunnelEntry 41 }
mplsTunnelLinkProtection OBJECT-TYPE
SYNTAX BITS {
extraTraffic(0),
unprotected (1),
shared (2),
dedicatedOneToOne (3),
dedicatedOnePlusOne (4),
enhanced (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This bitmask indicates the level of link protection required. A
value of zero (no bits set) indicates that any protection may be
used. The following describes these bitfields:
extraTraffic
Indicates that the LSP should use links that are protecting
other (primary) traffic. Such LSPs may be preempted when the
links carrying the (primary) traffic being protected fail.
unprotected
Indicates that the LSP should not use any link layer
protection.
shared
Indicates that a shared link layer protection scheme, such as
1:N protection, should be used to support the LSP.
dedicatedOneToOne
Indicates that a dedicated link layer protection scheme,
i.e., 1:1 protection, should be used to support the LSP.
dedicatedOnePlusOne
Indicates that a dedicated link layer protection scheme,
i.e., 1+1 protection, should be used to support the LSP.
enhanced
Indicates that a protection scheme that is more reliable than
Dedicated 1+1 should be used, e.g., 4 fiber BLSR/MS-SPRING.
This object is only meaningful if mplsTunnelLSPEncoding is
not set to 'tunnelLspNotGmpls'."
REFERENCE
"Berger, L., et al., Generalized Multi-Protocol
Label Switching (GMPLS) Signaling Functional
Description, RFC 3471, January 2003."
DEFVAL { {} }
::= { mplsTunnelEntry 42 }
mplsTunnelGPid OBJECT-TYPE
SYNTAX INTEGER {
unknown (0),
ds1SF (1),
ds1ESF (2),
ds3M23 (3),
ds3Cbit (4),
asyncE4 (5),
asyncDS3 (6),
asyncE3 (7),
bitSyncE3 (8),
byteSyncE3 (9),
asyncDS2 (10),
bitSyncDS2 (11),
byteSyncDS2 (12),
asyncE1 (13),
byteSyncE1 (14),
byteSync31DS0 (15),
asyncDS1 (16),
bitSyncDS1 (17),
byteSyncDS1 (18),
vcByteSyncDS2 (19),
vcAsyncE1 (20),
vcByteSyncE1 (21),
ds1SFAsync (22),
ds1ESFAsync (23),
ds3M23Async (24),
ds3CbitAsync (25),
vt (26),
sts (27),
pos16CRC (28),
pos32CRC (29),
posScrambling16CRC (30),
posScrambling32CRC (31),
atmMapping (32),
ethernet (33),
sdh (34),
sonet (35),
digitalWrapper (36),
lambda (37),
etsiPdh (38),
ansiPdh (39),
laps (40),
fddi (41),
dqdb (42),
fiberch3 (43),
hdlc (44),
etherV2di (45),
ether8023 (46),
etherGfpSonet (56)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the payload carried by the LSP.It is only
required when GMPLS will be used for this LSP.
Only valid if Generalized Label Request is in use as specified
by mplsTunnelLSPEncodingType.
This object is only meaningful if mplsTunnelLSPEncoding is not
set to 0"
DEFVAL { 0 }
::= { mplsTunnelEntry 43 }
mplsTunnelSecondary OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates that the requested LSP is a secondary LSP.
This is a GMPLS feature, and should only be used when GMPLS will be
be used for this LSP.
This object is only meaningful if mplsTunnelLSPEncoding is not
set to 0."
REFERENCE
"Berger, L., et al., Generalized Multi-Protocol
Label Switching (GMPLS) Signaling Functional
Description, RFC 3471, January 2003."
DEFVAL { false }
::= { mplsTunnelEntry 44 }
mplsTunnelDirection OBJECT-TYPE
SYNTAX INTEGER {
out (0),
outbidir (1),
-- PRVT-Addition
in (2),
hwbidir (3),
inbidir (4),
transuni (5),
transbi (6),
transbih (7)
-- End PRVT-Addition
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Whether this tunnel is unidirectional-incoming,
unidirectional-outgoing, bidirectional in hardware,
the terminator end of a signalled bidirectional
tunnel, the initiator end of a signalled
bidirectional tunnel, unidirectional at transit,
signalled bidirectional at transit, or bidirectional
in hardware at transit.
Values of this object other than 'out' are meaningful
only if mplsTunnelLSPEncoding is not set to 0."
DEFVAL { out }
::= { mplsTunnelEntry 45 }
mplsTunnelPathComp OBJECT-TYPE
SYNTAX INTEGER {
dynamicFull(1),-- CSPF fully computed
explicit(2),-- fully specified path
dynamicPartial(3) -- CSPF partially computed
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value instructs the source node on how to perform path
computation on the explicit route specified by the associated
entries in the mplsTunnelHopTable.
dynamicFull
The user specifies at least the source and
destination of the path and expects that the CSPF
will calculate the remainder of the path.
explicit
The user specifies the entire path for the tunnel to
take. This path may contain strict or loose hops.
Evaluation of the explicit route will be performed
hop by hop through the network.
dynamicPartial
The user specifies at least the source and
destination of the path and expects that the CSPF
will calculate the remainder of the path. The path
computed by CSPF is allowed to be only partially
computed allowing the remainder of the path to be
filled in across the network.
This object deprecates mplsTunnelHopEntryPathComp."
DEFVAL { dynamicFull }
::= { mplsTunnelEntry 46 }
mplsTunnelUpNotRecipType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Type of upstream notify recipient address for this tunnel."
DEFVAL { unknown }
::= { mplsTunnelEntry 101 }
mplsTunnelUpNotRecip OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the address of the upstream recipient for Notify
messages relating to this tunnel.
This object is only valid when signaling a tunnel using RSVP. It
is also not valid at the tail end of the tunnel.
If set to 0, no Notify Request object will be included in
outgoing Path messages."
REFERENCE
"Generalized MPLS Signaling - RSVP-TE Extensions, Berger,
L. (Editor), RFC 3473, January 2003."
::= { mplsTunnelEntry 47 }
mplsTunnelDownNotRecipType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Type of downstream notify recipient address for this tunnel."
DEFVAL { unknown }
::= { mplsTunnelEntry 102 }
mplsTunnelDownNotRecip OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the address of the downstream recipient for Notify
messages relating to this tunnel.
This object is only valid when signaling a tunnel using RSVP. It
is also not valid at the head end of the tunnel.
If set to 0, no Notify Request object will be included in
outgoing Resv messages."
REFERENCE
"Generalized MPLS Signaling - RSVP-TE Extensions, Berger, L.
(Editor), RFC 3473, January 2003."
::= { mplsTunnelEntry 48 }
mplsTunnelAdminStatusFlags OBJECT-TYPE
SYNTAX BITS {
delInProgress (0),
adminDown (1),
testing (2),
reserved3 (3), -- reserved
reserved4 (4), -- reserved
reserved5 (5), -- reserved
reserved6 (6), -- reserved
reserved7 (7), -- reserved
reserved8 (8), -- reserved
reserved9 (9), -- reserved
reserved10 (10), -- reserved
reserved11 (11), -- reserved
reserved12 (12), -- reserved
reserved13 (13), -- reserved
reserved14 (14), -- reserved
reserved15 (15), -- reserved
reserved16 (16), -- reserved
reserved17 (17), -- reserved
reserved18 (18), -- reserved
reserved19 (19), -- reserved
reserved20 (20), -- reserved
reserved21 (21), -- reserved
reserved22 (22), -- reserved
reserved23 (23), -- reserved
reserved24 (24), -- reserved
reserved25 (25), -- reserved
reserved26 (26), -- reserved
reserved27 (27), -- reserved
reserved28 (28), -- reserved
reserved29 (29), -- reserved
reserved30 (30), -- reserved
reflect (31)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Determines the setting of the Admin Status flags in the
Admin Status object or TLV, as described in RFC 3471. Setting
this field to a non-zero value will result in the inclusion of
the admin status object on signaling messages.
If the prvtMplsTeMibAllowGracefulDeletion product MIB field
is set, then the delInProgress flag is
not writable. Instead, Use the deletion_mode setting to
indicate whether Graceful deletion should be used for
the tunnel.
This value of this object can be modified when the
corresponding mplsTunnelRowStatus and mplsTunnelAdminStatus
is active(1). By doing so, a new signaling message will be
triggered including the requested Admin Status object or
TLV."
REFERENCE
"Berger, L., et al., Generalized Multi-Protocol Label Switching
(GMPLS) Signaling Functional Description, RFC 3471,
January 2003."
DEFVAL { { } }
::= { mplsTunnelEntry 49 }
mplsTunnelExtraParamsPtr OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Some Tunnels will run over transports that can usefully support
technology-specific additional parameters (for example, SONET
resource usage). Such parameters can be supplied in an external
table and referenced from here.
In this implementation of the mplsTunnelTable, the row must either
be set to zeroDotZero, or must point at an entry in the
mplsTunnelSonetResTable.
If a value other than zeroDotZero is used, then
mplsTunnelResourcePointer must be set to zeroDotZero."
::= { mplsTunnelEntry 50 }
mplsTunnelUseEgressLabel OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Whether or not to use an explicit route Label subobject as
configured in mplsTunnelEgressLabel."
DEFVAL { false }
::= { mplsTunnelEntry 51 }
mplsTunnelEgressLabel OBJECT-TYPE
SYNTAX MplsGeneralizedLabel
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The egress control Label in the explicit route, and its
length.
At ingress, this value must be inserted as the last hop of the
explicit route.
At egress this is the value of the received Label subobject.
Since 0 is a valid value, the validity of this field is
indicated by mplsTunnelUseEgressLabel.
When this label is used in signaling protocol messages,
it is copied byte for byte as is. Therefore, if the label
octet string is intended to represent multibyte values, it
should encode those values in network (big-endian) byte
order. This interpretation applies in particular to the
non-generalized MPLS labels (32 bits) used in ATM, FR and
generic MPLS networks."
::= { mplsTunnelEntry 52 }
mplsTunnelEgressLabelType OBJECT-TYPE
SYNTAX MplsGeneralizedLabelType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The C-Type of the egress control Label configured in
mplsTunnelEgressLabel."
::= { mplsTunnelEntry 53 }
mplsTunnelOmitEROIfOneHop OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether the explicit route object should be
omitted from the Path message when the tunnel consists of
just one loose hop.
Note that if mplsTunnelHopTableIndex is set to 0, the
tunnel is routed to the address configured in
mplsTunnelEgressLSRId. This avoids the need to configure
a single loose hop containing the tunnel's destination
address and setting this field to true."
DEFVAL { false }
::= { mplsTunnelEntry 54 }
mplsTunnelPrivateData OBJECT-TYPE
SYNTAX MplsTunnelPrivateDataSyntax
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object contains the customer defined private data for
the forward signaling direction. At ingress it is
filled in with the private data present on the MIB SET
message. Note that this field can be updated even when
the Tunnel is OperUp.
At egress it is filled in with the decoded forward private
data.
Note that there is a separate MIB field for the reverse
signaling direction private data,
mplsTunnelReversePrivateData."
::= { mplsTunnelEntry 55 }
mplsTunnelSrcTNAAddressType OBJECT-TYPE
SYNTAX INTEGER {
none (0),
ipv4 (1),
ipv6 (2),
nsap (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Type of the source TNA address of this tunnel. This field
is used for UNI. For standard MPLS and GMPLS, this field
must be set to none."
DEFVAL { none }
::= { mplsTunnelEntry 56 }
mplsTunnelSrcTNAAddress OBJECT-TYPE
SYNTAX MplsTunnelTNAAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Source TNA address of this tunnel. This field is only
valid if mplsTunnelSrcTNAAddressType is not none."
::= { mplsTunnelEntry 57 }
mplsTunnelDestTNAAddressType OBJECT-TYPE
SYNTAX INTEGER {
none (0),
ipv4 (1),
ipv6 (2),
nsap (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Type of the destination TNA address of this tunnel. This
field is used for UNI. For standard MPLS and GMPLS, this
field must be set to none."
DEFVAL { none }
::= { mplsTunnelEntry 58 }
mplsTunnelDestTNAAddress OBJECT-TYPE
SYNTAX MplsTunnelTNAAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Destination TNA address of this tunnel. This field is only
valid if mplsTunnelDestTNAAddressType is not none."
::= { mplsTunnelEntry 59 }
mplsTunnelEndToEndRerouting OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates that Crankback End to End rerouting should be
enabled on this LSP. Setting this flag will cause Rerouting
information to be returned to the ingress node on PathErrs
and Notifications.
No Rerouting information will be included if the Path
Message does not contain an ERO. Rerouting
information will be limited to 'Node' errors unless a
switch managed label space is used."
DEFVAL { false }
::= { mplsTunnelEntry 60 }
mplsTunnelIsUni OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This flag indicates whether the tunnel is to conform to
UNI 1.0."
DEFVAL { false }
::= { mplsTunnelEntry 62 }
mplsTunnelUniServiceLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the UNI service level. It is only valid when
_is_uni_ is set to true."
::= { mplsTunnelEntry 63 }
mplsTunnelUniEgressLabel OBJECT-TYPE
SYNTAX MplsGeneralizedLabel
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The label to be used at the destination UNI in the
forward direction.
This field is only valid if one of mplsTunnelIsUni or
mplsTunnelIsSpc is set, and must be filled in if
mplsTunnelIsSpc is set."
::= { mplsTunnelEntry 64 }
mplsTunnelUniEgressLabelType OBJECT-TYPE
SYNTAX MplsGeneralizedLabelType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The C-Type of the forward label to be used at the
destination UNI.
This field is only valid if one of mplsTunnelIsUni or
mplsTunnelIsSpc is set, and must be filled in if
mplsTunnelIsSpc is set."
::= { mplsTunnelEntry 65 }
mplsTunnelUniEgressLabelPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The logical port identifier used to uniquely identify and
select a (forward) data link at the destination UNI.
This port identifier is relative to the destination UNI-C
for UNI-initiated connections, but is relative to the
destination UNI-N for connections that are initiated by
management at the source UNI-N.
This field is only valid if one of mplsTunnelIsUni or
mplsTunnelIsSpc is set, and must be filled in if
mplsTunnelIsSpc is set."
::= { mplsTunnelEntry 66 }
mplsTunnelUniRvsEgressLabel OBJECT-TYPE
SYNTAX MplsGeneralizedLabel
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The label to be used at the destination UNI in the
reverse direction.
This field is only valid if one of mplsTunnelIsUni or
mplsTunnelIsSpc is set, and must be filled in if
mplsTunnelIsSpc is set and the tunnel is bi-directional."
::= { mplsTunnelEntry 67 }
mplsTunnelUniRvsEgressLabelType OBJECT-TYPE
SYNTAX MplsGeneralizedLabelType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The C-Type of the reverse label to be used at the
destination UNI.
This field is only valid if one of mplsTunnelIsUni or
mplsTunnelIsSpc is set, and must be filled in if
mplsTunnelIsSpc is set and the tunnel is bi-directional."
::= { mplsTunnelEntry 68 }
mplsTunnelUniRvsEgressLabelPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The logical port identifier used to uniquely identify and
select a (reverse) data link at the destination UNI.
This port identifier is relative to the destination UNI-C
for UNI-initiated connections, but is relative to the
destination UNI-N for connections that are initiated by
management at the source UNI-N.
This field is only valid if one of mplsTunnelIsUni or
mplsTunnelIsSpc is set, and must be filled in if
mplsTunnelIsSpc is set and the tunnel is bi-directional."
::= { mplsTunnelEntry 69 }
mplsTunnelDeletionMode OBJECT-TYPE
SYNTAX INTEGER {
forced(1),
graceful(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Whether to use forced or graceful deletion to delete this
LSP. This field is ignored if graceful deletion is not
allowed in the TE-MIB entity MIB."
DEFVAL { forced }
::= { mplsTunnelEntry 70 }
mplsTunnelUniDiversityListIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "UNI specific. This field references a
prvtMplsTunnelUNIDivListIndex in the
mplsTunnelUNIDiversityTable, and defines this list of
tunnels to be diverse from. A value of zero indicates
that no diversity is configured.
Note that if the diversity requirements specified in the
referenced diversity list cannot be satisfied by
signaling, this tunnel will fail to move to oper_status
up. See the Description in the
mplsTunnelUNIDiversityTable for more information."
DEFVAL { 0 }
::= { mplsTunnelEntry 71 }
mplsTunnelDiffServIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index into the mplsDiffServTable entry that
specifies the L-LSP or E-LSP parameters to signal
when setting up the tunnel. If this field is not filled
in or is assigned the value zero then no DiffServ
parameters are signalled."
REFERENCE
"Le Faucher, et. al, MPLS Support of Differentiated
Services, Internet Draft <draft-ietf-mpls-diff-
ext-09.txt>, April 2001."
::= { mplsTunnelEntry 72 }
mplsTunnelReversePrivateData OBJECT-TYPE
SYNTAX MplsTunnelPrivateDataSyntax
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object contains the customer defined private data for
the reverse signaling direction. At egress it is
initially set by the RRR_EGRESS_TRANSLATE_PRIV_DATA user exit and
subsequently may be altered via MIB operations.
At ingress it is filled in with the decoded reverse
private data.
Note that there is a separate MIB field for the forward
signaling direction private data, mplsTunnelPrivateData."
::= { mplsTunnelEntry 73 }
mplsTunnelFastRerouteMode OBJECT-TYPE
SYNTAX INTEGER {
noFastReroute(0),
detourFastReroute(1),
facilityFastReroute(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether or not this tunnel should be protected
by a fast reroute mechanism, and if so which method should
be used.
noFastReroute - no fast reroute protection.
detourFastReroute - fast reroute protection using the
one-to-one detour backup method.
facilityFastReroute - fast reroute protection using the
facility backup method.
Fast reroute is only available for uni-directional LSPs."
DEFVAL { noFastReroute }
::= { mplsTunnelEntry 74 }
mplsTunnelBackupSetupPrio OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Setup priority for backup tunnels set up to protect this
tunnel. This field is only valid if the mplsTunnelFastRerouteMode
above is not noFastReroute."
::= { mplsTunnelEntry 75 }
mplsTunnelBackupHoldingPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Holding priority for backup tunnels set up to protect this
tunnel. This field is only valid if the mplsTunnelFastRerouteMode
above is not noFastReroute."
::= { mplsTunnelEntry 76 }
mplsTunnelBackupIncAny OBJECT-TYPE
SYNTAX MplsTunnelAffinity
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Include-any resource affinity for backup tunnels set up to
protect this tunnel.
A link satisfies the include-any constraint if and only if
the constraint is zero, or the link and the constraint
have a resource class in common.
This field is only valid if the mplsTunnelFastRerouteMode
above is not noFastReroute."
DEFVAL { 0 }
::= { mplsTunnelEntry 77 }
mplsTunnelBackupIncAll OBJECT-TYPE
SYNTAX MplsTunnelAffinity
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Include-all resource affinity for backup tunnels set up to
protect this tunnel.
A link satisfies the include-all constraint if and only if
the link contains all of the adminstrative groups
specified in the constraint.
This field is only valid if the mplsTunnelFastRerouteMode
above is not noFastReroute."
DEFVAL { 0 }
::= { mplsTunnelEntry 78 }
mplsTunnelBackupExcAny OBJECT-TYPE
SYNTAX MplsTunnelAffinity
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Exclude-any resource affinity for backup tunnels set up to
protect this tunnel.
A link satisfies the exclude-any constraint if and only if
the constraint is zero, or the link and the constraint
have a resource class in common.
This field is only valid if the mplsTunnelFastRerouteMode
above is not noFastReroute."
DEFVAL { 0 }
::= { mplsTunnelEntry 79 }
mplsTunnelBackupBandwidth OBJECT-TYPE
SYNTAX MplsBitRate
UNITS "1000s of bits per second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The estimated bandwidth required for backup tunnels, in
units of 1000 bits/second. A value of zero indicates
best-effort.
This field is only valid if the mplsTunnelFastRerouteMode
above is not noFastReroute."
DEFVAL { 0 }
::= { mplsTunnelEntry 80 }
mplsTunnelBackupMaxHops OBJECT-TYPE
SYNTAX Unsigned32(0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of extra hops the backup path is
allowed to take, from a Point of Local Repair (PLR) to a
Merge Point (MP), with PLR and MP excluded in counting.
A hop-limit of 0 means only direct links between PLR and MP
can be used.
This field is only valid if the mplsTunnelFastRerouteMode
above is not noFastReroute."
DEFVAL { 255 }
::= { mplsTunnelEntry 81 }
mplsTunnelIsSpc OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This flag indicates whether the tunnel is an OIF soft
permanent connection (SPC)."
DEFVAL { false }
::= { mplsTunnelEntry 84 }
mplsTunnelUniIngressLabel OBJECT-TYPE
SYNTAX MplsGeneralizedLabel
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The label to be used for the in-segment at the source
UNI-N in the forward direction.
This field is only valid if the mplsTunnelIsSpc field
is true."
::= { mplsTunnelEntry 85 }
mplsTunnelUniIngressLabelType OBJECT-TYPE
SYNTAX MplsGeneralizedLabelType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The C-Type of the forward label to be used for the
in-segment at the source UNI-N.
This field is only valid if the mplsTunnelIsSpc field
is true."
::= { mplsTunnelEntry 86 }
mplsTunnelUniIngressLabelPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The logical port identifier used to uniquely identify and
select a (forward) data link for the in-segment at the
source UNI-N.
This field is only valid if the mplsTunnelIsSpc field
is true."
::= { mplsTunnelEntry 87 }
mplsTunnelUniRvsIngrLabel OBJECT-TYPE
SYNTAX MplsGeneralizedLabel
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The label to be used at the source UNI-N for the
out-segment in the reverse direction.
This field is only valid if the mplsTunnelIsSpc field
is true."
::= { mplsTunnelEntry 88 }
mplsTunnelUniRvsIngrLabelType OBJECT-TYPE
SYNTAX MplsGeneralizedLabelType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The C-Type of the reverse label to be used for the
out-segment at the source UNI-N.
This field is only valid if the mplsTunnelIsSpc field
is true."
::= { mplsTunnelEntry 89 }
mplsTunnelUniRvsIngrLabelPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The logical port identifier used to uniquely identify and
select a data link for the reverse out-segment at the
source UNI-N.
This field is only valid if the mplsTunnelIsSpc field
is true."
::= { mplsTunnelEntry 90 }
mplsTunnelDiffServClassType OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "DiffServ Class-Type of the LSP as defined in
draft-ietf-tewg-diff-te-proto-03."
DEFVAL { 0 }
::= { mplsTunnelEntry 91 }
mplsTunnelExtendedProtection OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates that the requested LSP should use the extended PROTECTION
object as defined in draft-lang-ccamp-gmpls-recovery-e2e-signaling.
This is a GMPLS feature, and should only be used when GMPLS will
be used for this LSP."
DEFVAL { false }
::= { mplsTunnelEntry 92 }
mplsTunnelProtecting OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates that the requested LSP is a protecting LSP and not a
working LSP.
This field is only valid if mplsTunnelExtendedProtection is true."
DEFVAL { false }
::= { mplsTunnelEntry 93 }
mplsTunnelNotification OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates that the control plane message exchange is only used for
notification during protection switching.
This field is only valid if mplsTunnelExtendedProtection is true."
DEFVAL { false }
::= { mplsTunnelEntry 94 }
mplsTunnelLspProtection OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This field indicates the level of end-to-end protection
for this LSP.
This field is only valid if mplsTunnelExtendedProtection is true.
A value of zero indicates that no protection is provided for the
tunnel.
This field is not a bitmask; only one LSP protection may be selected.
See draft-lang-ccamp-gmpls-recovery-e2e-signaling for a
description of the possible values."
DEFVAL { 0 }
::= { mplsTunnelEntry 95 }
mplsTunnelAssociatedLspId OBJECT-TYPE
SYNTAX MplsTunnelInstanceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The mplsTunnelInstance of an associated tunnel between the
same ingress and egress and with the same mplsTunnelIndex.
If this field is zero, the associated LSP ID is not known,
or there are multiple.
This field is only valid if mplsTunnelExtendedProtection is true."
DEFVAL { 0 }
::= { mplsTunnelEntry 96 }
mplsTunnelCallIdType OBJECT-TYPE
SYNTAX INTEGER {
operatorSpecific(1),
globallyUnique(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The C-Type of the following CALL ID. This field is
insignificant if the mplsTunnelCallId has zero length.
This field can only be changed when the Admin Status is down."
::= { mplsTunnelEntry 97 }
mplsTunnelCallId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The CALL ID to be used on this tunnel, including the
address type, International and National segment (if applicable),
source transport network element address, and Local
Identifier as defined in G.7713.2 (version 0.8).
This field can only be changed when the Admin Status is down."
::= { mplsTunnelEntry 98 }
mplsTunnelIsIpv6 OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Flag indicating whether this tunnel uses IPv6 addresses.
If this flag is set, the tunnel may only be activated if
- TE-MIB is configured to allow IPv6 tunnels
- the hop path index is non-zero
- all hops in the hop path have IPv6 addresses
- the first and last hops in the hop path have global
scope addresses."
DEFVAL { false }
::= {mplsTunnelEntry 100}
mplsTunnelMtu OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Maximal transfer unit of the tunnel"
::= { mplsTunnelEntry 103 }
mplsTunnelRebuildTimer OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Defines a period in minutes (0..1440), after which the tunnel will be unconditionally
rebuild. The maximal valid value is 1440 minutes (24 hours)"
DEFVAL { 60 }
::= { mplsTunnelEntry 104 }
mplsTunnelOperStatusFlags OBJECT-TYPE
SYNTAX BITS { empty(0),
tunnelResignalling(1),
tunnelSuppressed(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Flags to extend the information of the tunnel state
For the behaviour - bits meaning:
tunnelResignalling (1) - This status shows that currently the tunnel
has been resignalled. The resignalling state of a tunnel
should be considered together with the mplsTunnelOperStatus
attribute value of the same tunnel.
tunnelSuppressed (2) - This status shows that the tunnel has
been established, but higher priority tunnel is active
and in use. This tunnel can be activated, once the higher
protocol tunnel fails by any reason, and in this case
the tunnelSuppressed status will be cleared.
"
::= { mplsTunnelEntry 105 }
mplsTunnelGuardedDest OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The guarded destination object specifies which IP destination address the current
tunnel protects used with the fast reroute feature.
The tunnel must not be fast reroute enabled."
::= { mplsTunnelEntry 106 }
mplsTunnelMBBTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the timer configuration (in minutes) for Make-before-break (MBB).
The default value of this object is 10 minutes."
::= { mplsTunnelEntry 107 }
-- End Addition
-- End of mplsTunnelTable
-- Addition
mplsTunnelHopIndexNextTable OBJECT-TYPE
-- FAMILY-SHORT-NAME MPLS_HOPNI
SYNTAX SEQUENCE OF MplsTunnelHopIndexNextEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the next available values of
mplsTunnelHopIndex for all entities."
::= { mplsTeObjects 3 }
mplsTunnelHopIndexNextEntry OBJECT-TYPE
SYNTAX MplsTunnelHopIndexNextEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents the next available
mplsTunnelHopIndex for a specific TE-MIB entity.
This MIB table is indexed by the PRVT-TE-MIB entity Index."
INDEX { prvtMplsTeMibEntityIndex }
::= { mplsTunnelHopIndexNextTable 1 }
MplsTunnelHopIndexNextEntry ::= SEQUENCE {
mplsTunnelHopIndexNextIndex Unsigned32
}
-- End Addition
mplsTunnelHopIndexNextIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an appropriate value to be used
for mplsTunnelHopListIndex when creating entries in
the mplsTunnelHopTable. If the number of
unassigned entries is exhausted, a retrival
operation will return a value of 0. This object
may also return a value of 0 when the LSR is unable
to accept conceptual row creation, for example, if
the mplsTunnelHopTable is implemented as read-only.
To obtain the value of mplsTunnelHopListIndex for a
new entry in the mplsTunnelHopTable, the manager
issues a management protocol retrieval operation to
obtain the current value of mplsTunnelHopIndex.
After each retrieval operation, the agent should
modify the value to reflect the next unassigned
index. After a manager retrieves a value the agent
will determine through its local policy when this
index value will be made available for reuse."
::= { mplsTunnelHopIndexNextEntry 1 }
mplsTunnelHopTable OBJECT-TYPE
-- FAMILY-SHORT-NAME MPLS_HOP
SYNTAX SEQUENCE OF MplsTunnelHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTunnelHopTable is used to indicate the hops,
strict or loose, for an MPLS tunnel defined in
mplsTunnelTable, when it is established via
signaling, for the outgoing direction of the
tunnel. Each row in this table is indexed by
mplsTunnelHopListIndex. Each row also has a
secondary index mplsTunnelHopIndex corresponding to
the next hop that this row corresponds to. The
first row in the table is the first hop after the
origination point of the tunnel. In case we want
to specify a particular interface on the
originating LSR of an outgoing tunnel by which we
want packets to exit the LSR, we specify this as
the first hop for this tunnel in
mplsTunnelHopTable."
::= { mplsTeObjects 4 }
mplsTunnelHopEntry OBJECT-TYPE
SYNTAX MplsTunnelHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a tunnel hop. An
entry is created by a network administrator for
signaled ERLSP set up by an MPLS signaling
protocol."
INDEX { prvtMplsTeMibEntityIndex, mplsTunnelHopListIndex,
mplsTunnelHopPathOptionIndex, mplsTunnelHopIndex }
::= { mplsTunnelHopTable 1 }
MplsTunnelHopEntry ::= SEQUENCE {
mplsTunnelHopListIndex MplsPathIndex,
mplsTunnelHopPathOptionIndex MplsPathIndex,
mplsTunnelHopIndex MplsPathIndex,
mplsTunnelHopAddrType TeHopAddressType,
mplsTunnelHopIpAddr TeHopAddress,
mplsTunnelHopIpPrefixLen Unsigned32,
mplsTunnelHopAsNumber TeHopAddressAS,
mplsTunnelHopAddrUnnum TeHopAddressUnnum,
mplsTunnelHopLspId MplsLSPID,
mplsTunnelHopType INTEGER,
mplsTunnelHopInclude TruthValue,
mplsTunnelHopPathOptionName DisplayString,
mplsTunnelHopEntryPathComp INTEGER,
mplsTunnelHopRowStatus RowStatus,
mplsTunnelHopStorageType StorageType,
mplsTunnelHopLabelStatuses BITS,
mplsTunnelHopExpLabelType MplsGeneralizedLabelType,
mplsTunnelHopExpLabel MplsGeneralizedLabel,
mplsTunnelHopExpRvrsLabelType MplsGeneralizedLabelType,
mplsTunnelHopExpRvrsLabel MplsGeneralizedLabel
}
mplsTunnelHopListIndex OBJECT-TYPE
SYNTAX MplsPathIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Primary index into this table identifying a
particular explicit route object."
::= { mplsTunnelHopEntry 1 }
mplsTunnelHopPathOptionIndex OBJECT-TYPE
SYNTAX MplsPathIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Secondary index into this table identifying a
particular group of hops representing a particular
configured path. This is otherwise known as a path
option."
::= { mplsTunnelHopEntry 2 }
mplsTunnelHopIndex OBJECT-TYPE
SYNTAX MplsPathIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Secondary index into this table identifying a
particular hop."
::= { mplsTunnelHopEntry 3 }
mplsTunnelHopAddrType OBJECT-TYPE
SYNTAX TeHopAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The Hop Address Type of this tunnel hop.
The value of this object cannot be changed
if the value of the corresponding
mplsTunnelHopRowStatus object is 'active'.
Note that lspid(5) is a valid option only
for tunnels signaled via CRLDP.
"
DEFVAL { 1 }
::= { mplsTunnelHopEntry 4 }
mplsTunnelHopIpAddr OBJECT-TYPE
SYNTAX TeHopAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The Tunnel Hop Address for this tunnel hop.
The type of this address is determined by the
value of the corresponding mplsTunnelHopAddrType.
The value of this object cannot be changed
if the value of the corresponding
mplsTunnelHopRowStatus object is 'active'.
"
::= { mplsTunnelHopEntry 5 }
mplsTunnelHopIpPrefixLen OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "If mplsTunnelHopAddrType is set to ipv4(1) or
ipv6(2), then this value will contain an
appropriate prefix length for the IP address in
object mplsTunnelHopIpAddr. Otherwise this value
is irrelevant and should be ignored.
"
DEFVAL { 32 }
::= { mplsTunnelHopEntry 6 }
mplsTunnelHopAsNumber OBJECT-TYPE
SYNTAX TeHopAddressAS
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If mplsTunnelHopAddrType is set to asnumber(3), then
this value will contain the AS number of this hop.
Otherwise the agent should set this object to zero-
length string and the manager should ignore this."
::= { mplsTunnelHopEntry 7 }
mplsTunnelHopAddrUnnum OBJECT-TYPE
SYNTAX TeHopAddressUnnum
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If mplsTunnelHopAddrType is set to unnum(4) or
unnumv6(6), then this value will contain the interface
identifier of the unnumbered interface for this hop.
This object should be used in conjunction with
mplsTunnelHopIpAddress which would contain the LSR
Router ID in this case. Otherwise the agent should
set this object to zero-length string and the
manager should ignore this."
::= { mplsTunnelHopEntry 8 }
mplsTunnelHopLspId OBJECT-TYPE
SYNTAX MplsLSPID
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If mplsTunnelHopAddrType is set to lspid(5), then
this value will contain the LSPID of a tunnel of
this hop. The present tunnel being configured is
tunneled through this hop (using label stacking).
This object is otherwise insignificant and should
contain a value of 0 to indicate this fact."
::= { mplsTunnelHopEntry 9 }
mplsTunnelHopType OBJECT-TYPE
SYNTAX INTEGER {
strict(1),
loose(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes whether this tunnel hop is routed in a
strict or loose fashion. The value of this object
has no meaning if the mplsTunnelHopInclude object
is set to 'false'."
DEFVAL { 2 }
::= { mplsTunnelHopEntry 10 }
mplsTunnelHopInclude OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If this value is set to true, then this indicates
that this hop must be included in the tunnel's
path. If this value is set to 'false', then this hop
must be avoided when calculating the path for this
tunnel. The default value of this object is 'true',
so that by default all indicated hops are included
in the CSPF path computation. If this object is set
to 'false' the value of mplsTunnelHopType should be
ignored."
DEFVAL { true }
::= { mplsTunnelHopEntry 11 }
mplsTunnelHopPathOptionName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The description of this series of hops as they
relate to the specified path option. The
value of this object SHOULD be the same for
each hop in the series that comprises a
path option."
::= { mplsTunnelHopEntry 12 }
mplsTunnelHopEntryPathComp OBJECT-TYPE
SYNTAX INTEGER {
dynamic(1), -- CSPF computed
explicit(2) -- strict hop
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If this value is set to dynamic, then the user
should only specify the source and destination of
the path and expect that the CSPF will calculate
the remainder of the path. If this value is set to
explicit, the user should specify the entire path
for the tunnel to take. This path may contain
strict or loose hops. Each hop along a specific
path SHOULD have this object set to the same value."
::= { mplsTunnelHopEntry 13 }
mplsTunnelHopRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable is used to create, modify, and/or
delete a row in this table. When a row in this
table is in active(1) state, no objects in that row
can be modified by the agent except
mplsTunnelHopRowStatus and
mplsTunnelHopStorageType."
::= { mplsTunnelHopEntry 14 }
mplsTunnelHopStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The storage type for this Hop entry. Conceptual
rows having the value 'permanent' need not
allow write-access to any columnar objects
in the row."
DEFVAL { 2 }
::= { mplsTunnelHopEntry 15 }
mplsTunnelHopLabelStatuses OBJECT-TYPE
SYNTAX BITS {
forwardPresent (0),
reversePresent (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This bitmask indicates the presence of labels indicated by the
mplsTunnelHopExpLabel and mplsTunnelHopExpRvrsLabel
objects.
For the Present bits, a set bit indicates that a label is
present for this hop in the route. This allows zero to be a
valid label value."
DEFVAL { { } }
::= { mplsTunnelHopEntry 16 }
mplsTunnelHopExpLabelType OBJECT-TYPE
SYNTAX MplsGeneralizedLabelType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes the type of the label configured in
mplsTunnelHopExpLabel."
::= { mplsTunnelHopEntry 17 }
mplsTunnelHopExpLabel OBJECT-TYPE
SYNTAX MplsGeneralizedLabel
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If mplsTunnelHopLabelStatuses object indicates that a forward
label is present then the label to use on this hop is found in
this object."
::= { mplsTunnelHopEntry 18 }
mplsTunnelHopExpRvrsLabelType OBJECT-TYPE
SYNTAX MplsGeneralizedLabelType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes the type of the label configured in
mplsTunnelHopExpRvrsLabel."
::= { mplsTunnelHopEntry 19 }
mplsTunnelHopExpRvrsLabel OBJECT-TYPE
SYNTAX MplsGeneralizedLabel
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If the mplsTunnelHopLabelStatuses object indicates that a
reverse label is present then the label to use on this
hop is found in this object."
::= { mplsTunnelHopEntry 20 }
-- End of mplsTunnelHopTable
-- Begin of mplsTunnelResourceTable
-- Addition
mplsTunnelResourceIndexNextTable OBJECT-TYPE
-- FAMILY-SHORT-NAME MPLS_RESNI
SYNTAX SEQUENCE OF MplsTunnelResourceIndexNextEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the next available values of
mplsTunnelResourceIndex for all entities."
::= { mplsTeObjects 5 }
mplsTunnelResourceIndexNextEntry OBJECT-TYPE
SYNTAX MplsTunnelResourceIndexNextEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents the next available
mplsTunnelResourceIndex for a specific TE-MIB entity.
This MIB table is indexed by the PRVT-TE-MIB entity Index."
INDEX { prvtMplsTeMibEntityIndex }
::= { mplsTunnelResourceIndexNextTable 1 }
MplsTunnelResourceIndexNextEntry ::= SEQUENCE {
mplsTunnelResourceIndexNextIndex Unsigned32
}
-- End Addition
mplsTunnelResourceIndexNextIndex OBJECT-TYPE
SYNTAX Unsigned32 (0.. 2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the next appropriate value to
be used for mplsTunnelResourceIndex when creating
entries in the mplsTunnelResourceTable. If the
number of unassigned entries is exhausted, a
retrival operation will return a value of 0. This
object may also return a value of 0 when the LSR is
unable to accept conceptual row creation, for
example, if the mplsTunnelTable is implemented as
read-only. To obtain the mplsTunnelResourceIndex
value for a new entry, the manager must first issue
a management protocol retrieval operation to obtain
the current value of this object. The agent should
modify the value to reflect the next unassigned
index after each retrieval operation. After a
manager retrieves a value the agent will determine
through its local policy when this index value will
be made available for reuse."
::= { mplsTunnelResourceIndexNextEntry 1 }
mplsTunnelResourceTable OBJECT-TYPE
-- FAMILY-SHORT-NAME MPLS_RES
SYNTAX SEQUENCE OF MplsTunnelResourceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTunnelResourceTable allows a manager to
specify which resources are desired for an MPLS
tunnel. This table also allows several tunnels to
point to a single entry in this table, implying
that these tunnels should share resources."
::= { mplsTeObjects 6 }
mplsTunnelResourceEntry OBJECT-TYPE
SYNTAX MplsTunnelResourceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a set of resources
for an MPLS tunnel. An entry can be created by a
network administrator or by an SNMP agent as
instructed by any MPLS signaling protocol."
INDEX { prvtMplsTeMibEntityIndex, mplsTunnelResourceIndex }
::= { mplsTunnelResourceTable 1 }
MplsTunnelResourceEntry ::= SEQUENCE {
mplsTunnelResourceIndex Unsigned32,
mplsTunnelResourceMaxRate MplsBitRate,
mplsTunnelResourceMeanRate MplsBitRate,
mplsTunnelResourceMaxBurstSize MplsBurstSize,
mplsTunnelResourceMeanBurstSize MplsBurstSize,
mplsTunnelResourceExBurstSize MplsBurstSize,
mplsTunnelResourceFrequency INTEGER,
mplsTunnelResourceWeight Unsigned32,
mplsTunnelResourceRowStatus RowStatus,
mplsTunnelResourceStorageType StorageType
}
mplsTunnelResourceIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies this row."
::= { mplsTunnelResourceEntry 1 }
mplsTunnelResourceMaxRate OBJECT-TYPE
SYNTAX MplsBitRate
UNITS "1000s of bits per second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum rate in units of 1000 bits/second.
Note that setting mplsTunnelResourceMaxRate,
mplsTunnelResourceMeanRate, and
mplsTunnelResourceMaxBurstSize to 0 indicates best-effort
treatment. This object is copied to an instance of
mplsTrafficParamMaxRate in mplsTrafficParamTable the OID
of which is copied into the corresponding
mplsInSegmentTrafficParamPtr.
If the ingress node sets a maximum rate of positive
infinity, the egress node will return a value of
positive infinity on the MIB GET response. This
special value may not be used when setting the maximum
rate with this MIB."
DEFVAL { 0 }
::= { mplsTunnelResourceEntry 2 }
mplsTunnelResourceMeanRate OBJECT-TYPE
SYNTAX MplsBitRate
UNITS "1000s of bits per second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The mean rate in units of 1000 bits/second.
This object is copied into an instance of
mplsTrafficParamMeanRate in the
mplsTrafficParamTable. The OID of this table entry
is then copied into the corresponding
mplsInSegmentTrafficParamPtr.
When resource allocation is performed as requested
by this TSpec object, it is copied into an entry in
mplsTrafficParamTable [LSRMIB]:
mplsTunnelInMeanRate to mplsTrafficParamMeanRate.
The OID of this entry is copied to
mplsInSegmentTrafficParamPtr of the corresponding
in-segment entry."
DEFVAL { 0 }
::= { mplsTunnelResourceEntry 3 }
mplsTunnelResourceMaxBurstSize OBJECT-TYPE
SYNTAX MplsBurstSize
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum burst size in bytes. This object is
copied to mplsInSegmentMaxBurstSize of the
corresponding in-segment.
When resource allocation is performed as requested
by this TSpec object, it is copied into an entry in
mplsTrafficParamTable [LSRMIB]:
mplsTunnelInMaxBurstSize to
mplsTrafficParamMaxBurstSize. The OID of this entry
is copied to mplsInSegmentTrafficParamPtr of the
corresponding in-segment entry."
DEFVAL { 0 }
::= { mplsTunnelResourceEntry 4 }
mplsTunnelResourceMeanBurstSize OBJECT-TYPE
SYNTAX MplsBurstSize
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The mean burst size in bytes. The implementations
which do not implement this variable must return 0
for this value and must not allow a user to set
this value."
DEFVAL { 0 }
::= { mplsTunnelResourceEntry 5 }
mplsTunnelResourceExBurstSize OBJECT-TYPE
SYNTAX MplsBurstSize
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Excess burst size in bytes. The implementations
which do not implement this variable must return
noSuchObject(0) exception for this object and must
not allow a user to set this value."
REFERENCE
"CR-LDP Specification, Section 4.3."
DEFVAL { 0 }
::= { mplsTunnelResourceEntry 6 }
mplsTunnelResourceFrequency OBJECT-TYPE
SYNTAX INTEGER {
unspecified(1),
frequent(2),
veryFrequent(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The granularity of the availability of committed
rate. The implementations which do not implement
this variable must return unspecified(1) for this
value and must not allow a user to set this value."
DEFVAL { unspecified }
::= { mplsTunnelResourceEntry 7 }
mplsTunnelResourceWeight OBJECT-TYPE
SYNTAX Unsigned32(0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The relative weight for using excess bandwidth above
its committed rate. The value of 0 means that
weight is not applicable for the CR-LSP."
DEFVAL { 0 }
::= { mplsTunnelResourceEntry 8 }
mplsTunnelResourceRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable is used to create, modify, and/or
delete a row in this table."
::= { mplsTunnelResourceEntry 9 }
mplsTunnelResourceStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable indicates the storage type for this
object."
DEFVAL { 2 }
::= { mplsTunnelResourceEntry 10 }
-- End mplsTunnelResourceTable
-- Tunnel Actual Route Hop table.
mplsTunnelARHopTable OBJECT-TYPE
-- FAMILY-SHORT-NAME MPLS_ARHOP
SYNTAX SEQUENCE OF MplsTunnelARHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTunnelARHopTable is used to indicate the
hops, strict or loose, for an MPLS tunnel defined
in mplsTunnelTable, as reported by the MPLS
signaling protocol, for the outgoing direction of
the tunnel. Each row in this table is indexed by
mplsTunnelARHopListIndex. Each row also has a
secondary index mplsTunnelARHopIndex, corresponding
to the next hop that this row corresponds to. The
first row in the table is the first hop after the
origination point of the tunnel. In case we want
to specify a particular interface on the
originating LSR of an outgoing tunnel by which we
want packets to exit the LSR, we specify this as
the first hop for this tunnel in
mplsTunnelARHopTable.
Please note that since the information necessary to
build entries within this table are not provided by
some MPLS signaling protocols, implementation of
this table is optional. Furthermore, since the
information in this table is actually provided by
the MPLS signaling protocol after the path has been
set-up, the entries in this table are provided only
for observation, and hence, all variables in this
table are accessible exclusively as read-only."
::= { mplsTeObjects 7 }
mplsTunnelARHopEntry OBJECT-TYPE
SYNTAX MplsTunnelARHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a tunnel hop. An
entry is created by a network administrator for
signaled ERLSP set up by an MPLS signaling
protocol."
INDEX { prvtMplsTeMibEntityIndex, mplsTunnelARHopListIndex,
mplsTunnelARHopIndex }
::= { mplsTunnelARHopTable 1 }
MplsTunnelARHopEntry ::= SEQUENCE {
mplsTunnelARHopListIndex MplsPathIndex,
mplsTunnelARHopIndex MplsPathIndex,
mplsTunnelARHopAddrType TeHopAddressType,
mplsTunnelARHopIpAddr TeHopAddress,
mplsTunnelARHopAddrUnnum TeHopAddressUnnum,
mplsTunnelARHopLspId MplsLSPID,
-- Addition
mplsTunnelARHopLabelStatuses BITS,
mplsTunnelARHopExpLabelType MplsGeneralizedLabelType,
mplsTunnelARHopExpLabel MplsGeneralizedLabel,
mplsTunnelARHopExpRvrsLabelType MplsGeneralizedLabelType,
mplsTunnelARHopExpRvrsLabel MplsGeneralizedLabel,
mplsTunnelARHopProtection BITS
-- End Addition
}
mplsTunnelARHopListIndex OBJECT-TYPE
SYNTAX MplsPathIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Primary index into this table identifying a
particular recorded hop list."
::= { mplsTunnelARHopEntry 1 }
mplsTunnelARHopIndex OBJECT-TYPE
SYNTAX MplsPathIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Secondary index into this table identifying the
particular hop."
::= { mplsTunnelARHopEntry 2 }
mplsTunnelARHopAddrType OBJECT-TYPE
SYNTAX TeHopAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Hop Address Type of this tunnel hop.
If the type value is set to ipv4(1) or ipv6(2). The tunnel path
can be determin using mplsTunnelARHopIpAddr object.
mplsTunnelARHopAddrUnnum and mplsTunnelARHopLspId
should not be used.
If the type value is set to unnum(4) or unnumv6(6). The tunnel path
can be determin using mplsTunnelARHopAddrUnnum object.
mplsTunnelARHopIpAddr and mplsTunnelARHopLspId
should not be used.
Note that lspid(5) is a valid option only
for tunnels signaled via CRLDP. The tunnel path
can be determin using mplsTunnelARHopLspId object.
mplsTunnelARHopIpAddr and mplsTunnelARHopAddrUnnum
should not be used.
Currently only ipv4(1) type is supported"
DEFVAL { 1 }
::= { mplsTunnelARHopEntry 3 }
mplsTunnelARHopIpAddr OBJECT-TYPE
SYNTAX TeHopAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Tunnel Hop Address for this tunnel hop.
The type of this address is determined by the
value of the corresponding mplsTunnelARHopAddrType.
If mplsTunnelARHopAddrType is set to ipv4(1) or
ipv6(2), then this value contains the LSR Router
ID of the unnumbered interface. Otherwise the agent
SHOULD set this object to the zero-length string
and the manager should ignore this object."
::= { mplsTunnelARHopEntry 4 }
mplsTunnelARHopAddrUnnum OBJECT-TYPE
SYNTAX TeHopAddressUnnum
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelARHopAddrType is set to unnum(4) or
unnumv6(6), then this value will contain the
interface identifier of the unnumbered interface
for this hop. This object should be used in
conjunction with mplsTunnelARHopIpAddr which would
contain the LSR Router ID in this case. Otherwise
the agent should set this object to zero-length
string and the manager should ignore this."
::= { mplsTunnelARHopEntry 5 }
mplsTunnelARHopLspId OBJECT-TYPE
SYNTAX MplsLSPID
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelARHopAddrType is set to lspid(5), then
this value will contain the LSP ID of this hop.
This object is otherwise insignificant and should
contain a value of 0 to indicate this fact."
::= { mplsTunnelARHopEntry 6 }
-- Addition
mplsTunnelARHopLabelStatuses OBJECT-TYPE
SYNTAX BITS {
forwardPresent (0),
reversePresent (1),
forwardGlobal (2),
reverseGlobal (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This bitmask indicates the presence and status of labels
indicated by the mplsTunnelARHopExpLabel and
mplsTunnelARHopExpRvrsLabel objects.
For the Present bits, a set bit indicates that a label is
present for this hop in the route. For the Global bits, a set
bit indicates that the label comes from the Global Label Space.
A clear bit indicates that this is a Per- Interface label. A
Global bit only has meaning if the corresponding Present bit is
set."
::= { mplsTunnelARHopEntry 7 }
mplsTunnelARHopExpLabelType OBJECT-TYPE
SYNTAX MplsGeneralizedLabelType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The C-Type of the following hop label. This field is
insignificant unless mplsTunnelARHopLabelStatuses has the
forwardPresent(0) or forwardGlobal(2) bits set."
::= { mplsTunnelARHopEntry 8 }
mplsTunnelARHopExpLabel OBJECT-TYPE
SYNTAX MplsGeneralizedLabel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelARHopLabelStatus has the present(0) bit set,
then this value indicates the label value used for this hop.
This object is otherwise insignificant and should
contain a value of 0.
When this label is read from a signaling protocol message,
it is copied byte for byte as is. Therefore, if the label
octet string is understood to represent multibyte values,
it encodes those values in network (big-endian) byte
order. This interpretation applies in particular to the
non-generalized MPLS labels (32 bits) used in ATM, FR and
generic MPLS networks."
::= { mplsTunnelARHopEntry 9 }
mplsTunnelARHopExpRvrsLabelType OBJECT-TYPE
SYNTAX MplsGeneralizedLabelType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The C-Type of the following hop label. This field is
insignificant unless mplsTunnelARHopLabelStatuses has the
reversePresent(1) or reverseGlobal(3) bits set."
::= { mplsTunnelARHopEntry 10 }
mplsTunnelARHopExpRvrsLabel OBJECT-TYPE
SYNTAX MplsGeneralizedLabel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the mplsTunnelARHopLabelStatuses object indicates that a
reverse label is present then the label in use on this
hop is found in this object."
::= { mplsTunnelARHopEntry 11 }
mplsTunnelARHopProtection OBJECT-TYPE
SYNTAX BITS {
localAvailable (0),
localInUse (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Availability and usage of protection on the reported link.
localAvailable
Indicates that the link downstream of this node is protected
via a local repair mechanism.
localInUse
Indicates that a local repair mechanism is in use to maintain
this tunnel (usually in the face of an outage of the link it
was previously routed over)."
::= { mplsTunnelARHopEntry 12 }
-- End Addition
-- End of mplsTunnelARHopTable
-- Tunnel Computed Hop table.
mplsTunnelCHopTable OBJECT-TYPE
-- FAMILY-SHORT-NAME MPLS_CHOP
SYNTAX SEQUENCE OF MplsTunnelCHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTunnelCHopTable is used to indicate the
hops, strict or loose, for an MPLS tunnel defined
in mplsTunnelTable, as computed by a constraint-
based routing protocol, based on the
mplsTunnelHopTable for the outgoing direction of
the tunnel. Each row in this table is indexed by
mplsTunnelCHopListIndex. Each row also has a
secondary index mplsTunnelCHopIndex, corresponding
to the next hop that this row corresponds to. The
first row in the table is the first hop after the
origination point of the tunnel. In case we want
to specify a particular interface on the
originating LSR of an outgoing tunnel by which we
want packets to exit the LSR, we specify this as
the first hop for this tunnel in
mplsTunnelCHopTable.
Please note that since the information necessary to
build entries within this table may not be
supported by some LSRs, implementation of this
table is optional. Furthermore, since the
information in this table is actually provided by
routing protocol after the path has been computed,
the entries in this table are provided only for
observation, and hence, all variables in this table
are accessible exclusively as read-only."
::= { mplsTeObjects 8 }
mplsTunnelCHopEntry OBJECT-TYPE
SYNTAX MplsTunnelCHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a tunnel hop. An
entry in this table is created by a constraint-
based routing protocol based on the hops specified
in the corresponding mplsTunnelHopTable."
INDEX { prvtMplsTeMibEntityIndex, mplsTunnelCHopListIndex,
mplsTunnelCHopIndex }
::= { mplsTunnelCHopTable 1 }
MplsTunnelCHopEntry ::= SEQUENCE {
mplsTunnelCHopListIndex MplsPathIndex,
mplsTunnelCHopIndex MplsPathIndex,
mplsTunnelCHopAddrType TeHopAddressType,
mplsTunnelCHopIpAddr TeHopAddress,
mplsTunnelCHopIpPrefixLen Unsigned32,
mplsTunnelCHopAsNumber TeHopAddressAS,
mplsTunnelCHopAddrUnnum TeHopAddressUnnum,
mplsTunnelCHopLspId MplsLSPID,
mplsTunnelCHopType INTEGER,
mplsTunnelCHopLabelStatuses BITS,
mplsTunnelCHopExpLabelType MplsGeneralizedLabelType,
mplsTunnelCHopExpLabel MplsGeneralizedLabel,
mplsTunnelCHopExpRvrsLabelType MplsGeneralizedLabelType,
mplsTunnelCHopExpRvrsLabel MplsGeneralizedLabel
}
mplsTunnelCHopListIndex OBJECT-TYPE
SYNTAX MplsPathIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Primary index into this table identifying a
particular computed hop list."
::= { mplsTunnelCHopEntry 1 }
mplsTunnelCHopIndex OBJECT-TYPE
SYNTAX MplsPathIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Secondary index into this table identifying the
particular hop."
::= { mplsTunnelCHopEntry 2 }
mplsTunnelCHopAddrType OBJECT-TYPE
SYNTAX TeHopAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Hop Address Type of this tunnel hop.
Note that lspid(5) is a valid option only
for tunnels signaled via CRLDP."
DEFVAL { 1 }
::= { mplsTunnelCHopEntry 3 }
mplsTunnelCHopIpAddr OBJECT-TYPE
SYNTAX TeHopAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Tunnel Hop Address for this tunnel hop.
The type of this address is determined by the
value of the corresponding mplsTunnelCHopAddrType.
If mplsTunnelCHopAddrType is set to unnum(4) or
unnumv6(6), then this value will contain the LSR
Router ID of the unnumbered interface. Otherwise
the agent should set this object to the zero-length
string and the manager SHOULD ignore this object."
::= { mplsTunnelCHopEntry 4 }
mplsTunnelCHopIpPrefixLen OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelCHopAddrType is set to ipv4(1) or
ipv6(2), then this value will contain an
appropriate prefix length for the IP address in
object mplsTunnelCHopIpAddr. Otherwise this value
is irrelevant and should be ignored.
"
DEFVAL { 32 }
::= { mplsTunnelCHopEntry 5 }
mplsTunnelCHopAsNumber OBJECT-TYPE
SYNTAX TeHopAddressAS
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelCHopAddrType is set to asnumber(3),
then this value will contain the AS number of this
hop. Otherwise the agent should set this object to
zero-length string and the manager should ignore
this."
::= { mplsTunnelCHopEntry 6 }
mplsTunnelCHopAddrUnnum OBJECT-TYPE
SYNTAX TeHopAddressUnnum
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelCHopAddrType is set to unnum(4) or
unnumv6(6), then this value will contain the unnumbered
interface identifier of this hop. This object should
be used in conjunction with mplsTunnelCHopIpAddr
which would contain the LSR Router ID in this case.
Otherwise the agent should set this object to zero-
length string and the manager should ignore this."
::= { mplsTunnelCHopEntry 7 }
mplsTunnelCHopLspId OBJECT-TYPE
SYNTAX MplsLSPID
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelCHopAddrType is set to lspid(5), then
this value will contain the LSP ID of this hop.
This object is otherwise insignificant and should
contain a value of 0 to indicate this fact."
::= { mplsTunnelCHopEntry 8 }
mplsTunnelCHopType OBJECT-TYPE
SYNTAX INTEGER { strict(1),
loose(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Denotes whether this is tunnel hop is routed in a
strict or loose fashion."
::= { mplsTunnelCHopEntry 9 }
mplsTunnelCHopLabelStatuses OBJECT-TYPE
SYNTAX BITS {
forwardPresent (0),
reversePresent (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This bitmask indicates the presence of labels indicated by the
mplsTunnelCHopExpLabel and mplsTunnelCHopExpRvrsLabel
objects.
A set bit indicates that a label is present for this hop in the
route thus allowing zero to be a valid label value."
::= { mplsTunnelCHopEntry 11 }
mplsTunnelCHopExpLabelType OBJECT-TYPE
SYNTAX MplsGeneralizedLabelType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The C-Type of the following hop label. This field is
insignificant unless mplsTunnelCHopLabelStatuses has the
forwardPresent(0) bit set."
::= { mplsTunnelCHopEntry 12 }
mplsTunnelCHopExpLabel OBJECT-TYPE
SYNTAX MplsGeneralizedLabel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The explicit out-segment label to use on the
forward path.
When this label is used in signaling protocol messages,
it is copied byte for byte as is. Therefore, if the label
octet string is intended to represent multibyte values, it
should encode those values in network (big-endian) byte
order. This interpretation applies in particular to the
non-generalized MPLS labels (32 bits) used in ATM, FR and
generic MPLS networks."
::= { mplsTunnelCHopEntry 13 }
mplsTunnelCHopExpRvrsLabelType OBJECT-TYPE
SYNTAX MplsGeneralizedLabelType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The C-Type of the following hop label. This field is
insignificant unless mplsTunnelCHopLabelStatuses has the
reversePresent(0) bit set."
::= { mplsTunnelCHopEntry 14 }
mplsTunnelCHopExpRvrsLabel OBJECT-TYPE
SYNTAX MplsGeneralizedLabel
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The explicit in-segment label to use on the
reverse path.
When this label is used in signaling protocol messages,
it is copied byte for byte as is. Therefore, if the label
octet string is intended to represent multibyte values, it
should encode those values in network (big-endian) byte
order. This interpretation applies in particular to the
non-generalized MPLS labels (32 bits) used in ATM, FR and
generic MPLS networks."
::= { mplsTunnelCHopEntry 15 }
-- End of mplsTunnelCHopTable
-- MPLS Tunnel Performance Table.
mplsTunnelPerfTable OBJECT-TYPE
-- FAMILY-SHORT-NAME MPLS_TPRF
SYNTAX SEQUENCE OF MplsTunnelPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides per-tunnel MPLS performance
information."
::= { mplsTeObjects 9 }
mplsTunnelPerfEntry OBJECT-TYPE
SYNTAX MplsTunnelPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table is created by the LSR for
every tunnel. Its is an extension to
mplsTunnelEntry."
AUGMENTS { mplsTunnelEntry }
::= { mplsTunnelPerfTable 1 }
MplsTunnelPerfEntry ::= SEQUENCE {
mplsTunnelPerfPackets Counter32,
mplsTunnelPerfHCPackets Counter64,
mplsTunnelPerfErrors Counter32,
mplsTunnelPerfBytes Counter32,
mplsTunnelPerfHCBytes Counter64
}
mplsTunnelPerfPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets forwarded by the tunnel."
::= { mplsTunnelPerfEntry 1 }
mplsTunnelPerfHCPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High capacity counter for number of packets
forwarded by the tunnel."
::= { mplsTunnelPerfEntry 2 }
mplsTunnelPerfErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of errored packets."
::= { mplsTunnelPerfEntry 3 }
mplsTunnelPerfBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bytes forwarded by the tunnel."
::= { mplsTunnelPerfEntry 4 }
mplsTunnelPerfHCBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High capacity counter for number of bytes forwarded
by the tunnel."
::= { mplsTunnelPerfEntry 5 }
-- End of mplsTunnelPerfTable
-- CR-LDP Tunnel Resource Table
mplsTunnelCRLDPResTable OBJECT-TYPE
-- FAMILY-SHORT-NAME MPLS_TCRS
SYNTAX SEQUENCE OF MplsTunnelCRLDPResEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTunnelCRLDPResTable allows a manager to
specify which CR-LDP-specific resources are desired
for an MPLS tunnel if that tunnel is signaled using
CR-LDP. Note that these attributes are in addition
to those specified in mplsTunnelResourceTable. This
table also allows several tunnels to point to a
single entry in this table, implying that these
tunnels should share resources."
::= { mplsTeObjects 10 }
mplsTunnelCRLDPResEntry OBJECT-TYPE
SYNTAX MplsTunnelCRLDPResEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a set of resources
for an MPLS tunnel established using CRLDP
(mplsTunnelSignallingProto equal to crldp (3)). An
entry can be created by a network administrator or
by an SNMP agent as instructed by any MPLS
signaling protocol."
INDEX { prvtMplsTeMibEntityIndex, mplsTunnelResourceIndex }
::= { mplsTunnelCRLDPResTable 1 }
MplsTunnelCRLDPResEntry ::= SEQUENCE {
mplsTunnelCRLDPResMeanBurstSize MplsBurstSize,
mplsTunnelCRLDPResExBurstSize MplsBurstSize,
mplsTunnelCRLDPResFrequency INTEGER,
mplsTunnelCRLDPResWeight Unsigned32,
mplsTunnelCRLDPResFlags Unsigned32,
mplsTunnelCRLDPResRowStatus RowStatus,
mplsTunnelCRLDPResStorageType StorageType
}
mplsTunnelCRLDPResMeanBurstSize OBJECT-TYPE
SYNTAX MplsBurstSize
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The mean burst size in bytes."
DEFVAL { 0 }
::= { mplsTunnelCRLDPResEntry 2 }
mplsTunnelCRLDPResExBurstSize OBJECT-TYPE
SYNTAX MplsBurstSize
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Excess burst size in bytes."
REFERENCE
"CR-LDP Specification, Section 4.3."
::= { mplsTunnelCRLDPResEntry 3 }
mplsTunnelCRLDPResFrequency OBJECT-TYPE
SYNTAX INTEGER {
unspecified(1),
frequent(2),
veryFrequent(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The granularity of the availability of committed
rate."
REFERENCE
"CR-LDP Specification, Section 4.3."
::= { mplsTunnelCRLDPResEntry 4 }
mplsTunnelCRLDPResWeight OBJECT-TYPE
SYNTAX Unsigned32(0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The relative weight for using excess bandwidth above
its committed rate. The value of 0 means that
weight is not applicable for the CR-LSP."
DEFVAL { 0 }
::= { mplsTunnelCRLDPResEntry 5 }
mplsTunnelCRLDPResFlags OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of the 1 byte Flags conveyed as part of
the traffic parameters during the establishment of
the CRLSP. The bits in this object are to be
interpreted as follows.
+==+==+==+==+==+==+==+==+
| Res |F6|F5|F4|F3|F2|F1|
+==+==+==+==+==+==+==+==+
Res - These bits are reserved. Zero on transmission.
Ignored on receipt.
F1 - Corresponds to the PDR.
F2 - Corresponds to the PBS.
F3 - Corresponds to the CDR.
F4 - Corresponds to the CBS.
F5 - Corresponds to the EBS.
F6 - Corresponds to the Weight.
Each flag if is a Negotiable Flag corresponding to a
Traffic Parameter. The Negotiable Flag value zero
denotes Not Negotiable and value one denotes
Negotiable."
DEFVAL { 0 }
::= { mplsTunnelCRLDPResEntry 6 }
mplsTunnelCRLDPResRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable is used to create, modify, and/or
delete a row in this table."
::= { mplsTunnelCRLDPResEntry 7 }
mplsTunnelCRLDPResStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable indicates the storage type for this
object."
DEFVAL { 2 }
::= { mplsTunnelCRLDPResEntry 8 }
-- End of CR-LDP Tunnel Resource Table
-- Addition
-- MPLS DiffServ Table
mplsDiffServIndexNextTable OBJECT-TYPE
-- FAMILY-SHORT-NAME MPLS_DSI
SYNTAX SEQUENCE OF MplsDiffServIndexNextEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the next available values of
mplsDiffServIndex for all entities."
::= { mplsTeObjects 11 }
mplsDiffServIndexNextEntry OBJECT-TYPE
SYNTAX MplsDiffServIndexNextEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents the next available
mplsDiffServIndex for a specific TE-MIB entity.
This MIB table is indexed by the PRVT-TE-MIB entity
Index."
INDEX { prvtMplsTeMibEntityIndex }
::= { mplsDiffServIndexNextTable 1 }
MplsDiffServIndexNextEntry ::= SEQUENCE {
mplsDiffServIndexNextIndex Integer32
}
mplsDiffServIndexNextIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the next appropriate value
to be used for mplsDiffServIndex when creating
entries in the mplsDiffServTable. If the number of
unassigned entries is exhausted, this object
will take on the value of 0. To obtain the
mplsDiffServIndex value for a new entry, the
manager must first issue a management protocol
retrieval operation to obtain the current value
of this object. The agent should modify the
value to reflect the next unassigned index after
each retrieval operation. After a manager
retrieves a value the agent will determine
through its local policy when this index value
will be made available for reuse."
::= { mplsDiffServIndexNextEntry 1 }
mplsDiffServTable OBJECT-TYPE
-- FAMILY-SHORT-NAME MPLS_DS
SYNTAX SEQUENCE OF MplsDiffServEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsDiffServTable allows DiffServ parameters to be
configured for DiffServ enabled LSPs signalled by the
mplsTunnelTable.
If a tunnel is an E-LSP, then fields in this table must be
set to indicate 0 - 8 EXP->PHB maps, and the number
of such maps, to be used by LSRs in the E-LSP to
determine the PHB to apply to incoming packets.
If a tunnel is an L-LSP, then fields in this table must be
set to indicate the PHB Scheduling Class (PSC) to use
for incoming packets."
REFERENCE
"Le Faucher, et. al, MPLS Support of Differentiated
Services, Internet Draft <draft-ietf-mpls-diff-
ext-09.txt>, April 2001."
::= { mplsTeObjects 12 }
mplsDiffServEntry OBJECT-TYPE
SYNTAX MplsDiffServEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents either a set of 0 -
8 EXP->PHB maps, and the number of such maps, for an
E-LSP or a PSC value for an L-LSP."
REFERENCE
"Le Faucher, et. al, MPLS Support of Differentiated
Services, Internet Draft <draft-ietf-mpls-diff-
ext-09.txt>, April 2001."
INDEX {
prvtMplsTeMibEntityIndex, mplsDiffServIndex
}
::= { mplsDiffServTable 1 }
MplsDiffServEntry ::= SEQUENCE {
mplsDiffServIndex Integer32,
mplsDiffServType INTEGER,
mplsDiffServLLSPPSC Integer32,
mplsDiffServELSPNumPHBs Integer32,
mplsDiffServELSPPHB0 Integer32,
mplsDiffServELSPPHB1 Integer32,
mplsDiffServELSPPHB2 Integer32,
mplsDiffServELSPPHB3 Integer32,
mplsDiffServELSPPHB4 Integer32,
mplsDiffServELSPPHB5 Integer32,
mplsDiffServELSPPHB6 Integer32,
mplsDiffServELSPPHB7 Integer32,
mplsDiffServRowStatus RowStatus
}
mplsDiffServIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies this row."
::= { mplsDiffServEntry 1 }
mplsDiffServType OBJECT-TYPE
SYNTAX INTEGER { elsp(0), llsp(1) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This field must be set to indicate whether this row
contains parameters for an E-LSP or an L-LSP."
::= { mplsDiffServEntry 2 }
mplsDiffServLLSPPSC OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Valid only when mplsDiffServType takes the value l-lsp
(1), this field contains the16-bit encoding of the
PHB Scheduling Class (PSC) to be used for packets on
this LSP (RFC 3140)."
::= { mplsDiffServEntry 3 }
mplsDiffServELSPNumPHBs OBJECT-TYPE
SYNTAX Integer32 (0..8)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Valid only when mplsDiffServType takes the value e-lsp
(0), this value indicates the number of EXP->PHB
maps defined in this row."
::= { mplsDiffServEntry 4 }
mplsDiffServELSPPHB0 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Valid only when mplsDiffServType takes the value e-lsp
(0), this field contains the 16-bit encoding of the
PHB (RFC 3140) which is assigned to packets on this
LSP with the value 0 in the EXP field of their MPLS
shim header."
::= { mplsDiffServEntry 5 }
mplsDiffServELSPPHB1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Valid only when mplsDiffServType takes the value e-lsp
(0), this field contains the 16-bit encoding of the
PHB (RFC 3140) which is assigned to packets on this
LSP with the value 1 in the EXP field of their MPLS
shim header."
::= { mplsDiffServEntry 6 }
mplsDiffServELSPPHB2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Valid only when mplsDiffServType takes the value e-lsp
(0), this field contains the 16-bit encoding of the
PHB (RFC 3140) which is assigned to packets on this
LSP with the value 2 in the EXP field of their MPLS
shim header."
::= { mplsDiffServEntry 7 }
mplsDiffServELSPPHB3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Valid only when mplsDiffServType takes the value e-lsp
(0), this field contains the 16-bit encoding of the
PHB (RFC 3140) which is assigned to packets on this
LSP with the value 3 in the EXP field of their MPLS
shim header."
::= { mplsDiffServEntry 8 }
mplsDiffServELSPPHB4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Valid only when mplsDiffServType takes the value e-lsp
(0), this field contains the 16-bit encoding of the
PHB (RFC 3140) which is assigned to packets on this
LSP with the value 4 in the EXP field of their MPLS
shim header."
::= { mplsDiffServEntry 9 }
mplsDiffServELSPPHB5 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Valid only when mplsDiffServType takes the value e-lsp
(0), this field contains the 16-bit encoding of the
PHB (RFC 3140) which is assigned to packets on this
LSP with the value 5 in the EXP field of their MPLS
shim header."
::= { mplsDiffServEntry 10 }
mplsDiffServELSPPHB6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Valid only when mplsDiffServType takes the value e-lsp
(0), this field contains the 16-bit encoding of the
PHB (RFC 3140) which is assigned to packets on this
LSP with the value 6 in the EXP field of their MPLS
shim header."
::= { mplsDiffServEntry 11 }
mplsDiffServELSPPHB7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Valid only when mplsDiffServType takes the value e-lsp
(0), this field contains the 16-bit encoding of the
PHB (RFC 3140) which is assigned to packets on this
LSP with the value 7 in the EXP field of their MPLS
shim header."
::= { mplsDiffServEntry 12 }
mplsDiffServRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable is used to create, modify, and/or
delete a row in this table."
::= { mplsDiffServEntry 13 }
-- End of MPLS DiffServ Table
-- UNI Diversity table.
prvtMplsTunnelUNIDvLstIdxNxtTable OBJECT-TYPE
-- FAMILY-SHORT-NAME MPLS_DIVNI
SYNTAX SEQUENCE OF PrvtMplsTunnelUNIDvLstIdxNxtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the next available values of
prvtMplsTunnelUNIDivListIdx for all entities."
::= { mplsTeObjects 13 }
prvtMplsTunnelUNIDvLstIdxNxtEntry OBJECT-TYPE
SYNTAX PrvtMplsTunnelUNIDvLstIdxNxtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents the next available
prvtMplsTunnelUNIDivListIdx for a specific TE-MIB entity.
This MIB table is indexed by the PRVT-TE-MIB entity Index."
INDEX { prvtMplsTeMibEntityIndex }
::= { prvtMplsTunnelUNIDvLstIdxNxtTable 1 }
PrvtMplsTunnelUNIDvLstIdxNxtEntry ::= SEQUENCE {
prvtMplsTunnelUNIDivListIdxNext Integer32
}
prvtMplsTunnelUNIDivListIdxNext OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the next available List Index in the
prvtMplsTunnelUNIDiversityTable."
::= { prvtMplsTunnelUNIDvLstIdxNxtEntry 1 }
prvtMplsTunnelUNIDiversityTable OBJECT-TYPE
-- FAMILY-SHORT-NAME MPLS_DIV
SYNTAX SEQUENCE OF PrvtMplsTunnelUNIDiversityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The prvtMplsTunnelUNIDiversityTable is used to indicate which
existing tunnels a new UNI Connection is to be diverse from.
This table is UNI specific. Each
prvtMplsTunnelUNIDiversityTable is indexed using
prvtMplsTeMibEntityIndex, prvtMplsTunnelUNIDivListIdx,
prvtMplsTunnelUNIDivTnnlIdx.
To create a UNI tunnel to use Diversity, set up a row entry
in the prvtMplsTunnelUNIDiversityTable for each existing
tunnel that the new tunnel should be diverse from.
Then when creating the new UNI tunnel, set
prvtMplsTunnelUNIDiversityTableIndex in the mplsTunnelTable to
the list_index corresponding to the Diversity Table to be
used.
A diversity list is read-only if it is referenced by an
active row in the mplsTunnelTable that is admin_status up.
Under these circumstances, no individual rows/diversity
requirements making up the list can be added, modified or
deleted.
A list of diversity requirements can only be satisfied by
signaling if all of the referenced rows in the
mplsTunnelTable are oper_status up when signaling is
initiated. If the requirements cannot be satisfied, any
tunnel attempting to use the list will remain oper_status
down."
::= { mplsTeObjects 14 }
prvtMplsTunnelUNIDiversityEntry OBJECT-TYPE
SYNTAX PrvtMplsTunnelUNIDiversityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table corresponds to an entry in the mplsTunnelTable.
A subsequent Tunnel that references this entry will be created Diverse
from the tunnel row entry specified here."
INDEX { prvtMplsTeMibEntityIndex, prvtMplsTunnelUNIDivListIdx,
prvtMplsTunnelUNIDivIdx }
::= { prvtMplsTunnelUNIDiversityTable 1 }
PrvtMplsTunnelUNIDiversityEntry ::= SEQUENCE {
prvtMplsTunnelUNIDivListIdx Integer32,
prvtMplsTunnelUNIDivIdx Integer32,
prvtMplsTunnelUNIDivRowPointer RowPointer,
prvtMplsTunnelOperStatus Integer32,
prvtMplsTunnelUNIDivRowStatus RowStatus,
prvtMplsTunnelUNIDivRequirement INTEGER,
prvtMplsTunnelUNIDivAccess Integer32
}
prvtMplsTunnelUNIDivListIdx OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Primary index into this table identifying a
particular list of Diversity requirements."
::= { prvtMplsTunnelUNIDiversityEntry 2 }
prvtMplsTunnelUNIDivIdx OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Secondary index into this table identifying a
Diversity requirement within the list."
::= { prvtMplsTunnelUNIDiversityEntry 3 }
prvtMplsTunnelUNIDivRowPointer OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This field represents a pointer to the entry in the
mplsTunnelTable to which the Diversity requirement
applies. The array of longs specified here is configured
as the OID of the corresponding tunnel."
::= { prvtMplsTunnelUNIDiversityEntry 4 }
prvtMplsTunnelOperStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Oper Status of the mplsTunnelTable row referred to by
prvtMplsTunnelUNIDivPointer. If this tunnel is removed
from the mplsTunnelTable then this is set to AMB_OPER_STATUS_DOWN.
This field is used to determine whether a diversity
requirement can currently be satisfied by signaling."
::= { prvtMplsTunnelUNIDiversityEntry 5 }
prvtMplsTunnelUNIDivRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable is used to create or delete this row."
::= { prvtMplsTunnelUNIDiversityEntry 6 }
prvtMplsTunnelUNIDivRequirement OBJECT-TYPE
SYNTAX INTEGER {
nodeDiverse(1), -- node diverse
linkDiverse(2), -- link diverse
srlg(3), -- shared risk link group
sharedPath(4) -- shared path
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This field indicates the Diversity Requirement for the
corresponding tunnel. Once an row entry has been created
and is oper status 'up' for this tunnel this value cannot
be altered."
::= { prvtMplsTunnelUNIDiversityEntry 7 }
prvtMplsTunnelUNIDivAccess OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This field indicates the access (read-only or writable)
that the user has over this row entry.
The circumstances under which a row is read-only are
described above."
::= { prvtMplsTunnelUNIDiversityEntry 8 }
-- End of UNI Diversity table.
prvtMplsTunnelTrapEnableTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtMplsTunnelTrapEnableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The prvtMplsTunnelTrapEnable Table allows a manager to
enable or disable TRAPs."
::= { mplsTeObjects 15 }
prvtMplsTunnelTrapEnableEntry OBJECT-TYPE
SYNTAX PrvtMplsTunnelTrapEnableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table is used to configure trap support for this
instance of TE-MIB"
INDEX { prvtMplsTeMibEntityIndex }
::= { prvtMplsTunnelTrapEnableTable 1 }
PrvtMplsTunnelTrapEnableEntry ::= SEQUENCE {
mplsTunnelTrapEnable TruthValue
}
mplsTunnelTrapEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If this object is true, then it enables the
generation of mplsTunnelUp and mplsTunnelDown
traps, otherwise these traps are not emitted."
DEFVAL { false }
::= { prvtMplsTunnelTrapEnableEntry 2 }
-- Scalar table
mplsTunnelHoldTimer OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines a period in seconds needed to wait before rebuilding backup
or primary tunnels if a frr condition occurs
Currently no more than 10 seconds are allowed"
::= { mplsTeObjects 19 }
-- Addition
mplsTeMibEntityScalarTable OBJECT-TYPE
-- FAMILY-SHORT-NAME MPLS_SCALAR
SYNTAX SEQUENCE OF MplsTeMibEntityScalarEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTeMibEntityScalarTable contains all MPLS Tunnel
scalars."
::= { mplsTeObjects 16 }
mplsTeMibEntityScalarEntry OBJECT-TYPE
SYNTAX MplsTeMibEntityScalarEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTeMibEntityScalarTable contains all MPLS Tunnel
scalars."
INDEX { prvtMplsTeMibEntityIndex }
::= { mplsTeMibEntityScalarTable 1 }
MplsTeMibEntityScalarEntry ::= SEQUENCE {
mplsTunnelConfigured Unsigned32,
mplsTunnelActive Unsigned32,
mplsTunnelTEDistProto BITS,
mplsTunnelMaxHops Unsigned32,
mplsTunnelNotificationMaxRate Unsigned32
}
-- End Addition
mplsTunnelConfigured OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of tunnels configured on this device. A
tunnel is considered configured if the
mplsTunnelRowStatus is active(1)."
::= { mplsTeMibEntityScalarEntry 2 }
mplsTunnelActive OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of tunnels active on this device. A
tunnel is considered active if the
mplsTunnelOperStatus is up(1)."
::= { mplsTeMibEntityScalarEntry 3 }
mplsTunnelTEDistProto OBJECT-TYPE
SYNTAX BITS {
other (0),
ospf (1),
isis (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The traffic engineering distribution protocol(s)
used by this LSR. Note that an LSR may support more
than one distribution protocol simultaneously."
::= { mplsTeMibEntityScalarEntry 4 }
mplsTunnelMaxHops OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of hops that can be specified for
a tunnel on this device."
::= { mplsTeMibEntityScalarEntry 5 }
mplsTunnelNotificationMaxRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the maximum number of
notifications issued per second. If events occur
more rapidly, the implementation may simply fail to
emit these notifications during that period, or may
queue them until an appropriate time. A value of 0
means no throttling is applied and events may be
notified at the rate at which they occur."
DEFVAL { 0 }
::= { mplsTeMibEntityScalarEntry 6 }
-- PRVT-Addition
-- SONET Tunnel Resource Table
mplsTunnelSonetResTable OBJECT-TYPE
-- FAMILY-SHORT-NAME MPLS_TSRS
SYNTAX SEQUENCE OF MplsTunnelSonetResEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTunnelSonetResTable allows a manager to
specify which Sonet-specific resources are desired
for an MPLS tunnel. Note that these attributes are in addition
to those specified in mplsTunnelResourceTable. This
table also allows several tunnels to point to a
single entry in this table, implying that these
tunnels should share resources."
::= { mplsTeObjects 17 }
mplsTunnelSonetResEntry OBJECT-TYPE
SYNTAX MplsTunnelSonetResEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a set of Sonet resources
for an MPLS tunnel. An entry can be created by a
network administrator or by an SNMP agent as
instructed by any MPLS signaling protocol."
INDEX { prvtMplsTeMibEntityIndex, mplsTunnelResourceIndex }
::= { mplsTunnelSonetResTable 1 }
MplsTunnelSonetResEntry ::= SEQUENCE {
mplsTunnelSonetResRCC Integer32,
mplsTunnelSonetResNCC Unsigned32,
mplsTunnelSonetResNVC Unsigned32,
mplsTunnelSonetResMultiplier Unsigned32,
mplsTunnelSonetResTransparency Unsigned32,
mplsTunnelSonetResRowStatus RowStatus,
mplsTunnelSonetResSignalType Integer32
}
mplsTunnelSonetResRCC OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Requested Contiguous Concatenation. Indicates the types
of contiguous concatenation requested for this LSP. This
field is only valid if <lsp_encoding> is SDH or SONET, and the
<resource_pointer> is 0.0."
DEFVAL { 0 }
::= { mplsTunnelSonetResEntry 2 }
mplsTunnelSonetResNCC OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Requested Number of Contiguous Components. Indicates the
number of identical SDH/SONET SPEs/VCs that are
requested to be concatenated, as indicated in the <rcc>
field. This field is only valid if <lsp_encoding> is SDH
or SONET, and the <resource_pointer> is 0.0."
DEFVAL { 0 }
::= { mplsTunnelSonetResEntry 3 }
mplsTunnelSonetResNVC OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This field indicates the number of signals that are
requested to be virtually concatenated. These signals
are all of the same type. This field is valid only if
<lsp_encoding> is SDH or SONET, and the <resource_pointer> is 0.0."
DEFVAL { 0 }
::= { mplsTunnelSonetResEntry 4 }
mplsTunnelSonetResMultiplier OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This field is a bit field indicating the number of
identical signals that are requested for the LSP. This
field is valid only if <lsp_encoding> is SDH or SONET, and the
<resource_pointer> is 0.0."
DEFVAL { 1 }
::= { mplsTunnelSonetResEntry 5 }
mplsTunnelSonetResTransparency OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This field is a bit field indicating the type of
Transparency being requested. Several flags can be
combined to provide different types of transparency. Not
all combinations are necessarily valid. This field is
valid only if <lsp_encoding> is SDH or SONET, and the
<resource_pointer> is 0.0."
DEFVAL { 0 }
::= { mplsTunnelSonetResEntry 6 }
mplsTunnelSonetResRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable is used to create, modify, and/or
delete a row in this table."
::= { mplsTunnelSonetResEntry 7 }
mplsTunnelSonetResSignalType OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the overhead termination type and is interpreted
in relation to the LSP Encoding Type."
DEFVAL { 0 }
::= { mplsTunnelSonetResEntry 9 }
-- End of Sonet Tunnel Resource Table
-- GMPLS Tunnel Error Table.
mplsTunnelErrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsTunnelErrorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table 'augments' the mplsTunnelTable.
This table provides per-tunnel information about errors. Errors
may be detected locally or reported through the signaling
protocol. Error reporting is not exclusive to GMPLS and this
table may be applied in MPLS systems."
REFERENCE
"Multiprotocol Label Switching (MPLS) Traffic Engineering (TE)
Management Information Base (MIB), Srinivasan, C., Viswanathan,
A., Nadeau, T., RFC 3812, June 2004."
::= { mplsTeObjects 18 }
mplsTunnelErrorEntry OBJECT-TYPE
SYNTAX MplsTunnelErrorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table is created by the LSR for every tunnel
where error information is visible to the LSR.
Note that systems which read the objects in this table one at a
time may experience a discontinuity as the result of a new error
occurring in between object reads. Systems that are vulnerable
to this should read mplsTunnelErrorLastTime before and after
reading the other objects."
AUGMENTS { mplsTunnelEntry }
::= { mplsTunnelErrorTable 1 }
MplsTunnelErrorEntry ::= SEQUENCE {
mplsTunnelErrorLastErrorType INTEGER,
mplsTunnelErrorLastTime TimeStamp,
mplsTunnelErrorReporterType InetAddressType,
mplsTunnelErrorReporter InetAddress,
mplsTunnelErrorCode Unsigned32,
mplsTunnelErrorSubcode Unsigned32,
mplsTunnelErrorTLVs OCTET STRING,
mplsTunnelErrorHelpString DisplayString
}
mplsTunnelErrorLastErrorType OBJECT-TYPE
SYNTAX INTEGER {
noError (0),
unknown (1),
protocol (2),
pathComputation (3),
localConfiguration (4),
localResources (5),
localOther (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nature of the last error. Provides interpretation context
for mplsTunnelErrorProtocolCode and mplsTunnelErrorProtocolSubcode.
A value of noError (0) shows that there is no error associated
with this tunnel and means that the other objects in this table
entry have no meaning.
A value of unknown (1) shows that there is an error but that no
additional information about the cause is known. The error may
have been received in a signaled message or generated locally.
A value of protocol (2) or pathComputation (3) indicates that
the cause of an error and identifies an error that has been
received through signaling or will itself be signaled.
A value of localConfiguration (4), localResources (5) or
localOther (6) identifies an error which has been detected
by the local node, but which will not be reported through
signaling."
::= { mplsTunnelErrorEntry 1 }
mplsTunnelErrorLastTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time at which the last error occurred. This is presented as
the value of SysUpTime when the error occurred or was reported
to this node.
If mplsTunnelErrorLastErrorType has the value noError (0), then
this object is ignored."
::= { mplsTunnelErrorEntry 2 }
mplsTunnelErrorReporterType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The address type of the error reported.
This object is used to aid in interpretation of
mplsTunnelErrorReporter."
::= { mplsTunnelErrorEntry 3 }
mplsTunnelErrorReporter OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The address of the node reporting the last error, or the address
of the resource (such as an interface) associated with the
error.
If mplsTunnelErrorLastErrorType has the value noError (0), then
this object is ignored.
If mplsTunnelErrorLastErrorType has the value unknown (1),
localConfiguration (4), localResources (5), or localOther (6)
this object MAY contain a zero value.
This object should be interpreted in the context of the value of
the object mplsTunnelErrorReporterType."
REFERENCE
"RFC3291, Textual Conventions for Internet Network Addresses,
Section 4. Usage Hints."
::= { mplsTunnelErrorEntry 4 }
mplsTunnelErrorCode OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The primary error code associated with the last error.
The interpretation of this error code depends on the value of
mplsTunnelErrorLastErrorType. If the value of
mplsTunnelErrorLastErrorType is noError (0) the value of this
object should be 0 and should be ignored. If the value of
mplsTunnelErrorLastErrorType is protocol (2) the error should
be interpreted in the context of the signling protocol
identified by the mplsTunnelSignallingProto object.
Values in excess 32767 of are not used by signaling protocols
and may safely be used as implementation-specific error codes."
REFERENCE
"1. Braden, R. (Ed.) et al., Resource ReserVation Protocol --
Version 1 Functional Specification, RFC 2205, September 1997.
2. RSVP-TE: Extensions to RSVP for LSP Tunnels, Awduche et al.,
RFC 3209, December 2001.
3. Generalized MPLS Signaling - RSVP-TE Extensions, Berger, L.
(Editor), RFC 3473, January 2003."
::= { mplsTunnelErrorEntry 5 }
mplsTunnelErrorSubcode OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The secondary error code associated with the last error and the
protocol used to signal this tunnel. This value is interpreted
in the context of the value of mplsTunnelErrorCode.
If the value of mplsTunnelErrorLastErrorType is noError (0) the
value of this object should be 0 and should be ignored."
REFERENCE
"1. Braden, R. (Ed.) et al., Resource ReserVation Protocol --
Version 1 Functional Specification, RFC 2205, September 1997.
2. RSVP-TE: Extensions to RSVP for LSP Tunnels, Awduche et al.,
RFC 3209, December 2001.
3. Generalized MPLS Signaling - RSVP-TE Extensions, Berger, L.
(Editor), RFC 3473, January 2003."
::= { mplsTunnelErrorEntry 6 }
mplsTunnelErrorTLVs OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sequence of interface identifier TLVs reported with the
error by the protocol code. The interpretation of the TLVs and
the encoding within the protocol are described in the
references. A value of zero in the first octet indicates that no
TLVs are present."
REFERENCE
"Generalized MPLS Signaling - RSVP-TE Extensions, Berger, L.
(Editor), RFC 3473, January 2003."
::= { mplsTunnelErrorEntry 7 }
mplsTunnelErrorHelpString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing information about the last error,
recovery actions and support advice. If there is no help string
this object contains a zero length string.
If the value of mplsTunnelErrorLastErrorType is noError (0)
this object should contain a zero length string, but may contain
a help string indicating that there is no error."
::= { mplsTunnelErrorEntry 8 }
-- End Addition
-- Notifications.
mplsTunnelUp NOTIFICATION-TYPE
OBJECTS {
mplsTunnelAdminStatus,
mplsTunnelOperStatus
}
STATUS current
DESCRIPTION
"This notification is generated when a
mplsTunnelOperStatus object for one of the
configured tunnels is about to leave the down state
and transition into some other state (but not into
the notPresent state). This other state is
indicated by the included value of
mplsTunnelOperStatus.
This structure is the same as the generic
AMB_MPLS_TUNNEL_TRAP_COMMON."
::= { mplsTeNotifyPrefix 1 }
mplsTunnelDown NOTIFICATION-TYPE
OBJECTS {
mplsTunnelAdminStatus,
mplsTunnelOperStatus
}
STATUS current
DESCRIPTION
"This notification is generated when a
mplsTunnelOperStatus object for one of the
configured tunnels is about to enter the down state
from some other state (but not from the notPresent
state). This other state is indicated by the
included value of mplsTunnelOperStatus.
This structure is the same as the generic
AMB_MPLS_TUNNEL_TRAP_COMMON."
::= { mplsTeNotifyPrefix 2 }
mplsTunnelRerouted NOTIFICATION-TYPE
OBJECTS {
mplsTunnelAdminStatus,
mplsTunnelOperStatus,
mplsTunnelARHopTableIndex
}
STATUS current
DESCRIPTION
"This notification is generated when a tunnel is
rerouted. If the actual path is used, then this
object MAY contain the new path for this tunnel
some time after this trap is issued by the agent.
This structure is the same as the generic
AMB_MPLS_TUNNEL_TRAP_COMMON."
::= { mplsTeNotifyPrefix 3 }
mplsTunnelReoptimized NOTIFICATION-TYPE
OBJECTS {
mplsTunnelAdminStatus,
mplsTunnelOperStatus,
mplsTunnelARHopTableIndex
}
STATUS current
DESCRIPTION
"This notification is generated when a tunnel is
reoptimized. If the mplsTunnelARHopTable is used,
then this tunnel instance's entry in the
mplsTunnelARHopTable MAY contain the new path for
this tunnel some time after this trap is issued by
the agent.
This structure is the same as the generic
AMB_MPLS_TUNNEL_TRAP_COMMON."
::= { mplsTeNotifyPrefix 4 }
-- End of notifications.
-- Module compliance.
mplsTeGroups
OBJECT IDENTIFIER ::= { mplsTeConformance 1 }
mplsTeCompliances
OBJECT IDENTIFIER ::= { mplsTeConformance 2 }
mplsTeModuleFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for agents that provide full
support the MPLS-TE-STD-MIB module."
MODULE IF-MIB -- The Interfaces Group MIB, RFC 2863.
MANDATORY-GROUPS {
ifGeneralInformationGroup,
ifCounterDiscontinuityGroup
}
MODULE -- this module
-- The mandatory group has to be implemented by all
-- LSRs that originate/terminate ESLSPs/tunnels.
-- In addition, depending on the type of tunnels
-- supported, other groups become mandatory as
-- explained below.
MANDATORY-GROUPS {
mplsTunnelGroup,
mplsTunnelScalarGroup
}
GROUP mplsTunnelManualGroup
DESCRIPTION
"This group is mandatory for devices which support
manual configuration of tunnels."
GROUP mplsTunnelSignaledGroup
DESCRIPTION
"This group is mandatory for devices which support
signaled tunnel set up."
GROUP mplsTunnelIsNotIntfcGroup
DESCRIPTION
"This group is mandatory for devices which support
tunnels that are not interfaces."
GROUP mplsTunnelIsIntfcGroup
DESCRIPTION
"This group is mandatory for devices which support
tunnels that are interfaces."
GROUP mplsTunnelCRLDPResOptionalGroup
DESCRIPTION
"Objects in this group are required by
implementations supporting the CR-LDP protocol for
signalling of TE tunnels."
GROUP mplsTunnelSonetGroup
DESCRIPTION
"Set of objects needed to implement Sonet."
GROUP mplsTunnelUniGroup
DESCRIPTION
"Set of objects needed to implement UNI."
GROUP mplsTunnelBackupGroup
DESCRIPTION
"Set of objects needed for backup tunnels."
GROUP mplsTunnelARHopGroup
DESCRIPTION
"Set of objects relating to ARHop."
GROUP mplsTunnelCHopGroup
DESCRIPTION
"Set of objects relating to CHop."
GROUP mplsDiffServGroup
DESCRIPTION
"Set of objects relating to DiffServ."
GROUP mplsTeNotificationGroup
DESCRIPTION "This group is mandatory for those implementations
which can implement the notifications
contained in this group."
OBJECT mplsTunnelRowStatus
SYNTAX RowStatus { active(1), notInService(2) }
WRITE-SYNTAX RowStatus { active(1), notInService(2),
createAndGo(4), destroy(6)
}
DESCRIPTION "Support for createAndWait and notReady is not
required."
OBJECT mplsTunnelHopRowStatus
SYNTAX RowStatus { active(1), notInService(2) }
WRITE-SYNTAX RowStatus { active(1), notInService(2),
createAndGo(4), destroy(6)
}
DESCRIPTION "Support for createAndWait and notReady is not
required."
OBJECT mplsTunnelCRLDPResRowStatus
SYNTAX RowStatus { active(1), notInService(2) }
WRITE-SYNTAX RowStatus { active(1), notInService(2),
createAndGo(4), destroy(6)
}
DESCRIPTION "Support for createAndWait and notReady is
not required."
::= { mplsTeCompliances 1 }
-- Compliance requirement for read-only implementations.
mplsTeModuleReadOnlyCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance requirement for implementations that only
provide read-only support for MPLS-TE-STD-MIB.
Such devices can then be monitored but cannot be
configured using this MIB modules."
MODULE -- this module
-- mplsTunnelTable
MANDATORY-GROUPS {
mplsTunnelGroup,
mplsTunnelScalarGroup
}
GROUP mplsTunnelManualGroup
DESCRIPTION
"This group is mandatory for devices which support
manual configuration of tunnels."
GROUP mplsTunnelSignaledGroup
DESCRIPTION
"This group is mandatory for devices which support
signaled tunnel set up."
GROUP mplsTunnelIsNotIntfcGroup
DESCRIPTION
"This group is mandatory for devices which support
tunnels that are not interfaces."
GROUP mplsTunnelIsIntfcGroup
DESCRIPTION
"This group is mandatory for devices which support
tunnels that are interfaces."
GROUP mplsTunnelCRLDPResOptionalGroup
DESCRIPTION
"Objects in this group are required by
implementations supporting the CR-LDP protocol for
signalling of TE tunnels."
GROUP mplsTeNotificationGroup
DESCRIPTION "This group is mandatory for those implementations
which can implement the notifications
contained in this group."
-- mplsTunnelTable
OBJECT mplsTunnelName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelDescr
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelIsIf
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelIfIndex
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelXCPointer
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelSignallingProto
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelSetupPrio
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHoldingPrio
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelSessionAttributes
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelLocalProtectInUse
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourcePointer
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelInstancePriority
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopTableIndex
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelIncludeAnyAffinity
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelIncludeAllAffinity
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelExcludeAnyAffinity
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelPathInUse
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelRole
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelAdminStatus
SYNTAX INTEGER { up (1), down (2) }
MIN-ACCESS read-only
DESCRIPTION
"Only up and down states must be supported. Write
access is not required."
OBJECT mplsTunnelRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
-- mplsTunnelHopTable
OBJECT mplsTunnelHopAddrType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopIpAddr
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopIpPrefixLen
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopAddrUnnum
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopAsNumber
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopLspId
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopType
SYNTAX INTEGER { strict(1) }
MIN-ACCESS read-only
DESCRIPTION
"loose(2) need not be supported. Write access is
not required."
OBJECT mplsTunnelHopInclude
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopPathOptionName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopEntryPathComp
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopStorageType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
-- mplsTunnelResourceTable
OBJECT mplsTunnelResourceMaxRate
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourceMeanRate
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourceMaxBurstSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourceMeanBurstSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourceExBurstSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourceFrequency
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourceWeight
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourceRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourceStorageType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
-- mplsTunnelCRLDPResTable
OBJECT mplsTunnelCRLDPResMeanBurstSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelCRLDPResExBurstSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelCRLDPResFrequency
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelCRLDPResWeight
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelCRLDPResFlags
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelCRLDPResRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelCRLDPResStorageType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { mplsTeCompliances 2 }
-- Units of conformance.
mplsTunnelGroup OBJECT-GROUP
OBJECTS {
mplsTunnelIndexNextIndex,
mplsTunnelName,
mplsTunnelDescr,
mplsTunnelOwner,
mplsTunnelXCPointer,
mplsTunnelIfIndex,
mplsTunnelHopTableIndex,
mplsTunnelARHopTableIndex,
mplsTunnelCHopTableIndex,
mplsTunnelAdminStatus,
mplsTunnelOperStatus,
mplsTunnelRowStatus,
mplsTunnelStorageType,
mplsTunnelDirection,
mplsTunnelLSPEncoding,
mplsTunnelLinkProtection,
mplsTunnelGPid,
mplsTunnelUseEgressLabel,
mplsTunnelEgressLabel,
mplsTunnelEgressLabelType,
mplsTunnelOmitEROIfOneHop,
mplsTunnelPrivateData,
mplsTunnelSrcTNAAddressType,
mplsTunnelSrcTNAAddress,
mplsTunnelDestTNAAddressType,
mplsTunnelDestTNAAddress,
mplsTunnelSecondary,
mplsTunnelUnnumIf,
mplsTunnelAttributes,
mplsTunnelEndToEndRerouting,
mplsTunnelIsUni,
mplsTunnelUniServiceLevel,
mplsTunnelUniEgressLabel,
mplsTunnelUniEgressLabelType,
mplsTunnelUniEgressLabelPort,
mplsTunnelUniRvsEgressLabel,
mplsTunnelUniRvsEgressLabelType,
mplsTunnelUniRvsEgressLabelPort,
mplsTunnelSwitchingType,
mplsTunnelDeletionMode,
mplsTunnelUniDiversityListIndex,
mplsTunnelDiffServIndex,
mplsTunnelReversePrivateData,
mplsTunnelAdminStatusFlags,
mplsTunnelFastRerouteMode,
mplsTunnelBackupSetupPrio,
mplsTunnelBackupHoldingPriority,
mplsTunnelBackupIncAny,
mplsTunnelBackupIncAll,
mplsTunnelBackupExcAny,
mplsTunnelBackupBandwidth,
mplsTunnelBackupMaxHops,
mplsTunnelDownNotRecipType,
mplsTunnelDownNotRecip,
mplsTunnelPathComp,
mplsTunnelUpNotRecipType,
mplsTunnelUpNotRecip,
mplsTunnelExtraParamsPtr,
mplsTunnelIsSpc,
mplsTunnelUniIngressLabel,
mplsTunnelUniIngressLabelType,
mplsTunnelUniIngressLabelPort,
mplsTunnelUniRvsIngrLabel,
mplsTunnelUniRvsIngrLabelType,
mplsTunnelUniRvsIngrLabelPort,
mplsTunnelDiffServClassType,
mplsTunnelExtendedProtection,
mplsTunnelProtecting,
mplsTunnelNotification,
mplsTunnelLspProtection,
mplsTunnelAssociatedLspId,
mplsTunnelCallIdType,
mplsTunnelCallId,
mplsTunnelIsIpv6,
mplsTunnelConfigured,
mplsTunnelActive,
mplsTunnelPrimaryInstance,
mplsTunnelPrimaryUpTime,
mplsTunnelPathChanges,
mplsTunnelLastPathChange,
mplsTunnelCreationTime,
mplsTunnelStateTransitions,
mplsTunnelIncludeAnyAffinity,
mplsTunnelIncludeAllAffinity,
mplsTunnelExcludeAnyAffinity,
-- mplsTunnelPerfPackets,
-- mplsTunnelPerfHCPackets,
-- mplsTunnelPerfErrors,
-- mplsTunnelPerfBytes,
-- mplsTunnelPerfHCBytes,
mplsTunnelResourcePointer,
mplsTunnelInstancePriority,
mplsTunnelPathInUse,
mplsTunnelRole,
mplsTunnelTotalUpTime,
mplsTunnelInstanceUpTime,
mplsTunnelResourceMaxRate,
mplsTunnelResourceMeanRate,
mplsTunnelResourceMaxBurstSize,
mplsTunnelResourceMeanBurstSize,
mplsTunnelResourceExBurstSize,
mplsTunnelResourceFrequency,
mplsTunnelResourceWeight,
mplsTunnelResourceRowStatus,
mplsTunnelResourceStorageType,
mplsTunnelResourceIndexNextIndex,
mplsTunnelSonetResRCC,
mplsTunnelSonetResNCC,
mplsTunnelSonetResNVC,
mplsTunnelSonetResMultiplier,
mplsTunnelSonetResTransparency,
mplsTunnelSonetResRowStatus,
mplsTunnelARHopAddrType,
mplsTunnelARHopIpAddr,
mplsTunnelARHopAddrUnnum,
mplsTunnelARHopLspId,
mplsTunnelCHopAddrType,
mplsTunnelCHopIpAddr,
mplsTunnelCHopIpPrefixLen,
mplsTunnelCHopAsNumber,
mplsTunnelCHopAddrUnnum,
mplsTunnelCHopLspId,
mplsTunnelCHopType,
mplsTunnelTrapEnable,
mplsTunnelErrorLastErrorType,
mplsTunnelErrorLastTime,
mplsTunnelErrorReporterType,
mplsTunnelErrorReporter,
mplsTunnelErrorCode,
mplsTunnelErrorSubcode,
mplsTunnelErrorTLVs,
mplsTunnelErrorHelpString
}
STATUS current
DESCRIPTION
"Necessary, but not sufficient, set of objects to
implement tunnels. In addition, depending on the
type of the tunnels supported (for example,
manually configured or signaled, persistent or non-
persistent, etc.), the following other groups
defined below are mandatory: mplsTunnelManualGroup
and/or mplsTunnelSignaledGroup,
mplsTunnelIsNotIntfcGroup and/or
mplsTunnelIsIntfcGroup."
::= { mplsTeGroups 1 }
mplsTunnelManualGroup OBJECT-GROUP
OBJECTS { mplsTunnelSignallingProto }
STATUS current
DESCRIPTION
"Object(s) needed to implement manually configured
tunnels."
::= { mplsTeGroups 2 }
mplsTunnelSignaledGroup OBJECT-GROUP
OBJECTS {
mplsTunnelSetupPrio,
mplsTunnelHoldingPrio,
mplsTunnelSignallingProto,
mplsTunnelLocalProtectInUse,
mplsTunnelSessionAttributes,
mplsTunnelHopAddrType,
mplsTunnelHopIpAddr,
mplsTunnelHopIpPrefixLen,
mplsTunnelHopAddrUnnum,
mplsTunnelHopAsNumber,
mplsTunnelHopLspId,
mplsTunnelHopType,
mplsTunnelHopInclude,
mplsTunnelHopPathOptionName,
mplsTunnelHopEntryPathComp,
mplsTunnelHopRowStatus,
mplsTunnelHopStorageType,
mplsTunnelHopLabelStatuses,
mplsTunnelHopExpLabelType,
mplsTunnelHopExpLabel,
mplsTunnelHopExpRvrsLabelType,
mplsTunnelHopExpRvrsLabel,
mplsTunnelHopIndexNextIndex
}
STATUS current
DESCRIPTION
"Objects needed to implement signaled tunnels."
::= { mplsTeGroups 3 }
mplsTunnelScalarGroup OBJECT-GROUP
OBJECTS {
mplsTunnelConfigured,
mplsTunnelActive,
mplsTunnelTEDistProto,
mplsTunnelMaxHops,
mplsTunnelNotificationMaxRate
}
STATUS current
DESCRIPTION
"Scalar object needed to implement MPLS tunnels."
::= { mplsTeGroups 4 }
mplsTunnelIsIntfcGroup OBJECT-GROUP
OBJECTS { mplsTunnelIsIf }
STATUS current
DESCRIPTION
"Objects needed to implement tunnels that are
interfaces."
::= { mplsTeGroups 5 }
mplsTunnelIsNotIntfcGroup OBJECT-GROUP
OBJECTS { mplsTunnelIsIf }
STATUS current
DESCRIPTION
"Objects needed to implement tunnels that are not
interfaces."
::= { mplsTeGroups 6 }
mplsTunnelCRLDPResOptionalGroup OBJECT-GROUP
OBJECTS {
mplsTunnelCRLDPResMeanBurstSize,
mplsTunnelCRLDPResExBurstSize,
mplsTunnelCRLDPResFrequency,
mplsTunnelCRLDPResWeight,
mplsTunnelCRLDPResFlags,
mplsTunnelCRLDPResRowStatus,
mplsTunnelCRLDPResStorageType
}
STATUS current
DESCRIPTION
"Set of objects implemented for resources applicable
for tunnels signaled using CR-LDP."
::= { mplsTeGroups 7 }
mplsTunnelSonetGroup OBJECT-GROUP
OBJECTS {
mplsTunnelSonetResSignalType,
mplsTunnelSonetResRCC,
mplsTunnelSonetResNCC,
mplsTunnelSonetResNVC,
mplsTunnelSonetResMultiplier,
mplsTunnelSonetResTransparency
}
STATUS current
DESCRIPTION
"Set of objects needed to implement Sonet.
None of these objects are mandatory."
::= { mplsTeGroups 8 }
mplsTunnelUniGroup OBJECT-GROUP
OBJECTS {
mplsTunnelIsUni,
mplsTunnelUniServiceLevel,
mplsTunnelUniEgressLabel,
mplsTunnelUniEgressLabelType,
mplsTunnelUniEgressLabelPort,
mplsTunnelUniRvsEgressLabel,
mplsTunnelUniRvsEgressLabelType,
mplsTunnelUniRvsEgressLabelPort,
mplsTunnelUniDiversityListIndex,
mplsTunnelUniIngressLabelType,
mplsTunnelUniIngressLabelPort,
mplsTunnelUniIngressLabel,
mplsTunnelUniRvsIngrLabel,
mplsTunnelUniRvsIngrLabelType,
mplsTunnelUniRvsIngrLabelPort
}
STATUS current
DESCRIPTION
"Set of objects needed to implement UNI.
None of these objects are mandatory."
::= { mplsTeGroups 9 }
-- mplsTunnelUniDivGroup OBJECT-GROUP
-- OBJECTS {
-- prvtMplsTunnelUNIDivListIdxNext,
-- prvtMplsTunnelUNIDivRowPointer,
-- prvtMplsTunnelOperStatus,
-- prvtMplsTunnelUNIDivRowStatus,
-- prvtMplsTunnelUNIDivRequirement,
-- prvtMplsTunnelUNIDivAccess
-- }
-- STATUS current
-- DESCRIPTION
-- "Set of objects needed to implement UNI Diversity.
-- None of these objects are mandatory."
-- ::= { mplsTeGroups 10 }
mplsTunnelBackupGroup OBJECT-GROUP
OBJECTS {
mplsTunnelBackupSetupPrio,
mplsTunnelBackupHoldingPriority,
mplsTunnelBackupIncAny,
mplsTunnelBackupIncAll,
mplsTunnelBackupExcAny,
mplsTunnelBackupBandwidth,
mplsTunnelBackupMaxHops
}
STATUS current
DESCRIPTION
"Set of objects needed for backup tunnels.
None of these objects are mandatory."
::= { mplsTeGroups 11 }
mplsTunnelARHopGroup OBJECT-GROUP
OBJECTS {
mplsTunnelARHopAddrType,
mplsTunnelARHopIpAddr,
mplsTunnelARHopAddrUnnum,
mplsTunnelARHopLspId,
mplsTunnelARHopLabelStatuses,
mplsTunnelARHopExpLabelType,
mplsTunnelARHopExpLabel,
mplsTunnelARHopExpRvrsLabel,
mplsTunnelARHopExpRvrsLabelType,
mplsTunnelARHopProtection
}
STATUS current
DESCRIPTION
"Set of objects relating to ARHop.
None of these objects are mandatory."
::= { mplsTeGroups 12 }
mplsTunnelCHopGroup OBJECT-GROUP
OBJECTS {
mplsTunnelCHopAddrType,
mplsTunnelCHopIpAddr,
mplsTunnelCHopIpPrefixLen,
mplsTunnelCHopAsNumber,
mplsTunnelCHopAddrUnnum,
mplsTunnelCHopLspId,
mplsTunnelCHopType,
mplsTunnelCHopLabelStatuses,
mplsTunnelCHopExpLabelType,
mplsTunnelCHopExpLabel,
mplsTunnelCHopExpRvrsLabelType,
mplsTunnelCHopExpRvrsLabel
}
STATUS current
DESCRIPTION
"Set of objects relating to CHop.
None of these objects are mandatory."
::= { mplsTeGroups 13 }
mplsDiffServGroup OBJECT-GROUP
OBJECTS {
mplsDiffServIndexNextIndex,
mplsDiffServType,
mplsDiffServLLSPPSC,
mplsDiffServELSPNumPHBs,
mplsDiffServELSPPHB0,
mplsDiffServELSPPHB1,
mplsDiffServELSPPHB2,
mplsDiffServELSPPHB3,
mplsDiffServELSPPHB4,
mplsDiffServELSPPHB5,
mplsDiffServELSPPHB6,
mplsDiffServELSPPHB7,
mplsDiffServRowStatus
}
STATUS current
DESCRIPTION
"Set of objects relating to DiffServ.
None of these objects are mandatory."
::= { mplsTeGroups 14 }
mplsTeNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
mplsTunnelUp,
mplsTunnelDown,
mplsTunnelRerouted,
mplsTunnelReoptimized
}
STATUS current
DESCRIPTION
"Set of notifications implemented in this module.
None is mandatory."
::= { mplsTeGroups 15 }
-- End of MPLS-TE-MIB
END
|