1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
|
-- *****************************************************************
-- SUPERMICRO-SMI.mib: Super Micro Enterprise Structure of Management Information
--
-- October 26 2001, Software LAB
--
-- Copyright (c) 1993-2019 Super Micro Computer, Inc.
-- All rights reserved.
--
-- *****************************************************************
SUPERMICRO-HEALTH-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Integer32,
Gauge32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString,
TruthValue
FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF
smHealth
FROM SUPERMICRO-SMI;
smHealthMIB MODULE-IDENTITY
LAST-UPDATED "200110260000Z"
ORGANIZATION "Super Micro Computer Inc."
CONTACT-INFO
" Software Lab
Postal: 980 Rock Avenue
San Jose, CA 95131
USA
Tel: +1 408 503 8000
E-mail: SoftLab@supermicro.com"
DESCRIPTION
"MIB module for monitoring health information"
::= { smHealth 1 }
SMHealthInfoTypes ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents the different types of health information that
may be present in a managed device. The following health
information types are currently predefined:
0: fan speed
1: voltage
2: temperature
"
SYNTAX Integer32 (0..64)
smHealthObjects OBJECT IDENTIFIER ::= { smHealthMIB 1 }
smHealthMonitorTable OBJECT-TYPE
SYNTAX SEQUENCE OF SMHealthMonitorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of health monitoring entries."
::= { smHealthObjects 1 }
-- ================
smHealthMonitorEntry OBJECT-TYPE
SYNTAX SMHealthMonitorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the health monitoring table.
Entries cannot be created or deleted via SNMP operations."
INDEX { smHealthMonitorIndex }
::= { smHealthMonitorTable 1 }
SMHealthMonitorEntry ::=
SEQUENCE {
smHealthMonitorIndex Integer32,
smHealthMonitorName DisplayString,
smHealthMonitorType SMHealthInfoTypes,
smHealthMonitorReading Integer32,
smHealthMonitorHighLimit Integer32,
smHealthMonitorLowLimit Integer32,
smHealthMonitorMaxReading Integer32,
smHealthMonitorMinReading Integer32,
smHealthMonitorDivisor Integer32,
smHealthMonitorMonitor TruthValue,
smHealthMonitorReadingUnit DisplayString,
smHealthMonitorStatus Integer32
}
smHealthMonitorIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The unique value identifies this Monitor device."
::= { smHealthMonitorEntry 1 }
smHealthMonitorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual full name assigned to the Monitor device.
This object is suitable for output to a human operator."
::= { smHealthMonitorEntry 2 }
smHealthMonitorType OBJECT-TYPE
SYNTAX SMHealthInfoTypes
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies this Monitor device type."
::= { smHealthMonitorEntry 3 }
smHealthMonitorReading OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the reading value for the Monitor device that are currently in use on the managed device.
FAN readings are displayed in RPM.
Voltage readings are displayed in mV.
Temperture readings are displayed in Celsius."
::= { smHealthMonitorEntry 4 }
smHealthMonitorHighLimit OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the the High limit for the Monitor device that are currently in use on the managed device.
This is applied to Temperature and Voltage devices only.
Voltage limit is displayed in mV, and Temperture limit is displayed in Celsius."
::= { smHealthMonitorEntry 5 }
smHealthMonitorLowLimit OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the value for the Low limitation for the Monitor device that are currently in use on the managed device.
FAN limit is displayed in RPM, Voltage limit is displayed in mV, and Temperture limit is displayed in Celsius."
::= { smHealthMonitorEntry 6 }
smHealthMonitorMaxReading OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the value for the possible Maximum reading value for the Monitor device that are currently in use on the managed device.
FAN readings are displayed in RPM.
Voltage readings are displayed in mV.
Temperture readings are in Celsius."
::= { smHealthMonitorEntry 7 }
smHealthMonitorMinReading OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the value for the possible Minimum reading value for the Monitor device that are currently in use on the managed device.
FAN readings are displayed in RPM.
Voltage readings are displayed in mV.
Temperture readings are displayed in Celsius."
::= { smHealthMonitorEntry 8 }
smHealthMonitorDivisor OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the value for the Divisor for the Fan device that are currently in use on the managed device.
This is applied to Fan devices only."
::= { smHealthMonitorEntry 9 }
smHealthMonitorMonitor OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the monitoring status for the Fan device that are currently in use on the managed device.
0 = not monitored, 1 = monitored."
::= { smHealthMonitorEntry 10 }
smHealthMonitorReadingUnit OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the reading unit of the monitor device."
::= { smHealthMonitorEntry 11 }
smHealthMonitorStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the status of the monitor device. Values:
0: OK
1: Warning
2: Critical
"
::= { smHealthMonitorEntry 12 }
-- notifications
smHealthNotifications OBJECT IDENTIFIER ::= { smHealthMIB 2 }
-- (no notifications are currently defined)
-- conformance information
smHealthConformance OBJECT IDENTIFIER ::= { smHealthMIB 3 }
smHealthCompliances OBJECT IDENTIFIER ::= { smHealthConformance 1 }
smHealthGroups OBJECT IDENTIFIER ::= { smHealthConformance 2 }
-- compliance statements
smHealthCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which implement
the Supermicro Health Monitoring MIB"
MODULE -- this module
MANDATORY-GROUPS { smHealthMonitorGroup}
::= { smHealthCompliances 1 }
-- units of conformance
smHealthMonitorGroup OBJECT-GROUP
OBJECTS {
smHealthMonitorType,
smHealthMonitorName,
smHealthMonitorReading,
smHealthMonitorHighLimit,
smHealthMonitorLowLimit,
smHealthMonitorMaxReading,
smHealthMonitorMinReading,
smHealthMonitorMonitor
}
STATUS current
DESCRIPTION
"A collection of objects providing Monitor devices."
::= { smHealthGroups 1 }
smHealthAllinoneStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the all-in-one status of the monitoring items. Values:
0: OK
1: Warning
2: Critical
"
::= { smHealth 2 }
smHealthAllinoneMsg OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The all-in-one status message of the monitoring items."
::= { smHealth 3 }
END
|