summaryrefslogtreecommitdiff
path: root/MIBS/siae/SIAE-PMRXPWR-MIB
blob: 6bdc7021f677c78f93787d4a5e4b6278f19d6948 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
-- ----------------------------------------------------------------------------
--
--  SIAE MICROELETTRONICA s.p.a.
--                 
--  Via Michelangelo Buonarroti, 21
--  20093 - Cologno Monzese
--  Milano 
--  ITALY
--
-- ----------------------------------------------------------------------------
-- ----------------------------------------------------------------------------

SIAE-PMRXPWR-MIB
        DEFINITIONS ::= BEGIN

        IMPORTS
             MODULE-IDENTITY, OBJECT-TYPE,
             Counter32, Integer32, Unsigned32
        FROM SNMPv2-SMI
             DisplayString, RowStatus
        FROM SNMPv2-TC
             siaeMib
        FROM SIAE-TREE-MIB
             AlarmStatus, AlarmSeverityCode
        FROM SIAE-ALARM-MIB;

    pmRxPwr MODULE-IDENTITY
        LAST-UPDATED "201410070000Z"
        ORGANIZATION "SIAE MICROELETTRONICA spa"
        CONTACT-INFO

            "SIAE MICROELETTONICA s.p.a.
             Via Michelangelo Buonarroti, 21
             20093 - Cologno Monzese
             Milano - ITALY
             Phone :  +39-02-27325-1
             E-mail: tbd@siaemic.com
            "
        DESCRIPTION
            "Performance Monitoring on Received (RX) RF Power.
            "
        REVISION "201410070000Z"
        DESCRIPTION
            "Changed MAX-ACCESS caluse of some object of pmRxPwrTpClassTable
             from read-write to read-create
            "
        REVISION "201405130000Z"
        DESCRIPTION
            "Changed DEFVAL clause of pmRxPwrTpClassRltXThreshold.
            "
        REVISION "201402030000Z"
        DESCRIPTION
            "Improved description of pmRxPwrMibVersion
            "
        REVISION "201304160000Z"
        DESCRIPTION 
            "Initial version 01.00.00
            "
    ::= { siaeMib 12 }

----------------------------------------------------------------------------------
--  object identifier inside the module
----------------------------------------------------------------------------------

----------------------------------------------------------------------------------
--  pmRxPwr (PERFORMANCE MONITORING RECEIVED POWER LEVEL) GROUP
----------------------------------------------------------------------------------
--
--  The following objects are used to manage the Received Power Performance
--  Monitoring function.
--
----------------------------------------------------------------------------------

------ Beginning --------------------------------------------------------------

--
-------  The following table contains the records with  the counters used to monitor
-------  the received  power  of the radio.
-------  Begin of pmRxPwrCounterTable
--
    pmRxPwrMibVersion  OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Numerical version of this module.
             The string version of this MIB have the following format:
                XX.YY.ZZ
             so, for example, the value 1 should be interpreted as 00.00.01
             and the value 10001 should be interpreted as 01.00.01."
        DEFVAL {1}
    ::= {pmRxPwr 1}

    pmRxPwrCounterTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF PmRxPwrCounterRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table with PmRxPwr records: one record for 1+0 configuration and two
             record for 1+1 configuration."
    ::= {pmRxPwr 2}

    pmRxPwrCounterRecord  OBJECT-TYPE
        SYNTAX      PmRxPwrCounterRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "PmRxPwrCounter record."
        INDEX {pmRxPwrBranchId, pmRxPwrCounterBlockId}
    ::= {pmRxPwrCounterTable 1}

    PmRxPwrCounterRecord  ::=
        SEQUENCE {
            pmRxPwrBranchId            Integer32,
            pmRxPwrCounterBlockId      Integer32,
            pmRxPwrCounterBlockType    INTEGER,
            pmRxPwrCounterBlockStatus  INTEGER,
            pmRxPwrCounterTimeStamp    Unsigned32,
            pmRxPwrRlts1Counter        Counter32,
            pmRxPwrRlts2Counter        Counter32,
            pmRxPwrRlts3Counter        Counter32,
            pmRxPwrRlts4Counter        Counter32,
            pmRxPwrRlts5Counter        Counter32,
            pmRxPwrTMMax               Integer32,
            pmRxPwrTMMin               Integer32,
            pmRxPwrAverageRxLevel      Integer32
        }

    pmRxPwrBranchId  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object identifies the Radio Branch"
    ::= {pmRxPwrCounterRecord 1}

    pmRxPwrCounterBlockId  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object identifies  the counters block and the counter type
             according to the following code:
             1  Current Daily counters
             2  Daily counters (Day before counters)
             3  Current 15 minutes counters
             4  15 minutes counters N. 1 (The most recent 15 minutes counters)
                ..............................................
             n  15 minutes counters N. n
             20 15 minutes counters N.16(The oldest 15 min. counters 4 hours before)."
    ::= {pmRxPwrCounterRecord 2}

    pmRxPwrCounterBlockType  OBJECT-TYPE
        SYNTAX      INTEGER {
                             daily      (1),
                             fifteenMin (2)
                            }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The type of the counter block."
    ::= {pmRxPwrCounterRecord 3}

    pmRxPwrCounterBlockStatus  OBJECT-TYPE
        SYNTAX      INTEGER {
                             meaningless   (1),
                             meaningfull   (2),
                             incomplete    (3),
                             dummy         (4),
                             lost          (5),
                             restarted     (6)
                            }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Status of the block counter."
    ::= {pmRxPwrCounterRecord 4}

    pmRxPwrCounterTimeStamp  OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The object is the time when the performance record is closed reported
             as the second number since 1-Gen-1970."
    ::= {pmRxPwrCounterRecord 5}

    pmRxPwrRlts1Counter  OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of seconds when the Received power is less than the threshold 1."
    ::= {pmRxPwrCounterRecord 6}

    pmRxPwrRlts2Counter  OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of seconds when the Received power is less than the threshold 2"
    ::= {pmRxPwrCounterRecord 7}

    pmRxPwrRlts3Counter  OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of seconds when the Received power is less than the threshold 3"
    ::= {pmRxPwrCounterRecord 8}

    pmRxPwrRlts4Counter  OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of seconds when the Received power is less than the threshold 4"
    ::= {pmRxPwrCounterRecord 9}

    pmRxPwrRlts5Counter  OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of seconds when the Received power is less than the threshold 5"
    ::= {pmRxPwrCounterRecord 10}

    pmRxPwrTMMax  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Maximum Power Received Level Tide Mark."
    ::= {pmRxPwrCounterRecord 11}

    pmRxPwrTMMin  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Minimum Power Received Level Tide Mark."
    ::= {pmRxPwrCounterRecord 12}

    pmRxPwrAverageRxLevel OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            " Power Received Level  (Average value)"
    ::=  {pmRxPwrCounterRecord 13}
--
-------  End of pmRxPwrCounterTable

--
-------  The following table contains the records used to manage the P.M. on both
-------  radio branch and the threshold cross alarms
-------  Begin of pmRxPwrTpClassTable
--
    pmRxPwrTpClassTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF     PmRxPwrTpClassRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table with PmRxPwrTpClass records: one record for 1+0 configuration
             and two record for 1+1 configuration."
    ::= {pmRxPwr 3}

    pmRxPwrTpClassRecord  OBJECT-TYPE
        SYNTAX      PmRxPwrTpClassRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "PmRxPwrTpClass record."
        INDEX {pmRxPwrTpClassBranchId}
    ::= {pmRxPwrTpClassTable 1}

    PmRxPwrTpClassRecord  ::=
        SEQUENCE {
            pmRxPwrTpClassBranchId            Integer32,
            pmRxPwrTpClassStartStop           INTEGER,
            pmRxPwrTpClassLabel               DisplayString,
            pmRxPwrTpClassTimeStamp           Unsigned32,
            pmRxPwrTpClass15MRlts1Alarm       AlarmStatus,
            pmRxPwrTpClass15MRlts2Alarm       AlarmStatus,
            pmRxPwrTpClass15MRlts3Alarm       AlarmStatus,
            pmRxPwrTpClass15MRlts4Alarm       AlarmStatus,
            pmRxPwrTpClass15MRlts5Alarm       AlarmStatus,
            pmRxPwrTpClass24HRlts1Alarm       AlarmStatus,
            pmRxPwrTpClass24HRlts2Alarm       AlarmStatus,
            pmRxPwrTpClass24HRlts3Alarm       AlarmStatus,
            pmRxPwrTpClass24HRlts4Alarm       AlarmStatus,
            pmRxPwrTpClass24HRlts5Alarm       AlarmStatus,
            pmRxPwrTpClassRlt1Threshold       INTEGER,
            pmRxPwrTpClassRlt2Threshold       INTEGER,
            pmRxPwrTpClassRlt3Threshold       INTEGER,
            pmRxPwrTpClassRlt4Threshold       INTEGER,
            pmRxPwrTpClassRlt5Threshold       INTEGER,
            pmRxPwrTpClass15MRlts1Threshold   Integer32,
            pmRxPwrTpClass15MRlts2Threshold   Integer32,
            pmRxPwrTpClass15MRlts3Threshold   Integer32,
            pmRxPwrTpClass15MRlts4Threshold   Integer32,
            pmRxPwrTpClass15MRlts5Threshold   Integer32,
            pmRxPwrTpClass24HRlts1Threshold   Integer32,
            pmRxPwrTpClass24HRlts2Threshold   Integer32,
            pmRxPwrTpClass24HRlts3Threshold   Integer32,
            pmRxPwrTpClass24HRlts4Threshold   Integer32,
            pmRxPwrTpClass24HRlts5Threshold   Integer32,
            pmRxPwrTpClassRowStatus           RowStatus
        }

    pmRxPwrTpClassBranchId  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object identifies the Radio Branch"
    ::= {pmRxPwrTpClassRecord 1}

    pmRxPwrTpClassStartStop  OBJECT-TYPE
        SYNTAX      INTEGER {
                             start   (1),
                             stop    (2)
                            }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "This object is used to start and to stop the Perfomance Monitoring
             counter evaluation."
    ::= {pmRxPwrTpClassRecord 2}

    pmRxPwrTpClassLabel  OBJECT-TYPE
        SYNTAX      DisplayString   (SIZE(0..31))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "ASCII string used to identify the Tp class:
             pmRxPwrTpClassBranchId = 1 label = Radio 1
             pmRxPwrTpClassBranchId = 2 label = Radio 2."
    ::= {pmRxPwrTpClassRecord 3}

    pmRxPwrTpClassTimeStamp  OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The object is the time when the performance record is closed reported
             as the second number since 1/1/70."
    ::= {pmRxPwrTpClassRecord 4}

    pmRxPwrTpClass15MRlts1Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "15 minutes Rlts1 threshold cross alarm with associated severity."
    ::= {pmRxPwrTpClassRecord 5}

    pmRxPwrTpClass15MRlts2Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "15 minutes Rlts2 threshold cross alarm with associated severity."
    ::= {pmRxPwrTpClassRecord 6}

    pmRxPwrTpClass15MRlts3Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "15 minutes Rlts3 threshold cross alarm with associated severity."
    ::= {pmRxPwrTpClassRecord 7}

    pmRxPwrTpClass15MRlts4Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "15 minutes Rlts4 threshold cross alarm with associated severity."
    ::= {pmRxPwrTpClassRecord 8}

    pmRxPwrTpClass15MRlts5Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "15 minutes Rlts5 threshold cross alarm with associated severity."
    ::= {pmRxPwrTpClassRecord 9}

    pmRxPwrTpClass24HRlts1Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Daily Rlts1 threshold cross alarm with associated severity."
    ::= {pmRxPwrTpClassRecord 10}

    pmRxPwrTpClass24HRlts2Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Daily Rlts2 threshold cross alarm with associated severity."
    ::= {pmRxPwrTpClassRecord 11}

    pmRxPwrTpClass24HRlts3Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Daily Rlts3 threshold cross alarm with associated severity."
    ::= {pmRxPwrTpClassRecord 12}

    pmRxPwrTpClass24HRlts4Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Daily Rlts4 threshold cross alarm with associated severity."
    ::= {pmRxPwrTpClassRecord 13}

    pmRxPwrTpClass24HRlts5Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Daily Rlts5 threshold cross alarm with associated severity."
    ::= {pmRxPwrTpClassRecord 14}

    pmRxPwrTpClassRlt1Threshold  OBJECT-TYPE
        SYNTAX      INTEGER     (-100..-20)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Received Power Level Threshold 1 (dBm value); range -100 to -20"
        DEFVAL {-40}
    ::= {pmRxPwrTpClassRecord 15}

    pmRxPwrTpClassRlt2Threshold  OBJECT-TYPE
        SYNTAX      INTEGER     (-100..-20)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Received Power Level Threshold 2 (dBm value); range -100 to -20"
        DEFVAL {-50}
    ::= {pmRxPwrTpClassRecord 16}

    pmRxPwrTpClassRlt3Threshold  OBJECT-TYPE
        SYNTAX      INTEGER     (-100..-20)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Received Power Level Threshold 3 (dBm value); range -100 to -20"
        DEFVAL {-60}
    ::= {pmRxPwrTpClassRecord 17}

    pmRxPwrTpClassRlt4Threshold  OBJECT-TYPE
        SYNTAX      INTEGER     (-100..-20)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Received Power Level Threshold 4 (dBm value); range -100 to -20"
        DEFVAL {-70}
    ::= {pmRxPwrTpClassRecord 18}

    pmRxPwrTpClassRlt5Threshold  OBJECT-TYPE
        SYNTAX      INTEGER     (-100..-20)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Received Power Level Threshold 5 (dBm value); range -100 to -20"
        DEFVAL {-80}
    ::= {pmRxPwrTpClassRecord 19}

    pmRxPwrTpClass15MRlts1Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within 15 minutes to set
             pmRxPwrTpClass15MRlts1Alarm (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmRxPwrTpClassRecord 20}

    pmRxPwrTpClass15MRlts2Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within 15 minutes to set
             pmRxPwrTpClass15MRlts2Alarm (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmRxPwrTpClassRecord 21}

    pmRxPwrTpClass15MRlts3Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within 15 minutes to set
             pmRxPwrTpClass15MRlts3Alarm (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmRxPwrTpClassRecord 22}

    pmRxPwrTpClass15MRlts4Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within 15 minutes to set
             pmRxPwrTpClass15MRlts4Alarm (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmRxPwrTpClassRecord 23}

    pmRxPwrTpClass15MRlts5Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within 15 minutes to set
             pmRxPwrTpClass15MRlts5Alarm (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmRxPwrTpClassRecord 24}

    pmRxPwrTpClass24HRlts1Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within a day to set pmRxPwrTpClass24HRlts1Alarm
             (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmRxPwrTpClassRecord 25}

    pmRxPwrTpClass24HRlts2Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within a day to set pmRxPwrTpClass24HRlts2Alarm
             (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmRxPwrTpClassRecord 26}

    pmRxPwrTpClass24HRlts3Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within a day to set pmRxPwrTpClass24HRlts3Alarm
             (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmRxPwrTpClassRecord 27}

    pmRxPwrTpClass24HRlts4Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within a day to set pmRxPwrTpClass24HRlts4Alarm
             (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmRxPwrTpClassRecord 28}

    pmRxPwrTpClass24HRlts5Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within a day to set pmRxPwrTpClass24HRlts5Alarm
             (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmRxPwrTpClassRecord 29}

    pmRxPwrTpClassRowStatus   OBJECT-TYPE 
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Status of this row of pmRxPwrTpClass.
            "
    ::= {pmRxPwrTpClassRecord 30}


--
-------  End of pmRxPwrTpClassTable

--
--  MAINTENANCE TABLE
--

-------  Begin of pmRxPwrTpMaintTable
--
    pmRxPwrTpMaintTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF     PmRxPwrTpMaintRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table with Command for maintenance of Termination Point.
             Objects in this table is not persistent. An Instance of this 
             table is created on creation of pmRxPwrTpClassTable"
    ::= {pmRxPwr 4}

    pmRxPwrTpMaintRecord  OBJECT-TYPE
        SYNTAX      PmRxPwrTpMaintRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "PmG828 Termination Point Maintenance record."
        INDEX {pmRxPwrTpClassBranchId}
    ::= {pmRxPwrTpMaintTable 1}

    PmRxPwrTpMaintRecord  ::=
        SEQUENCE {
            pmRxPwrTpMaintCounterClear      INTEGER,
            pmRxPwrTpMaintAlarmClear        INTEGER
        }

    pmRxPwrTpMaintCounterClear  OBJECT-TYPE
        SYNTAX      INTEGER {
                             notActive   (0),
                             clear       (1)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object is used to clear the Perfomance Monitoring counters."
    ::= {pmRxPwrTpMaintRecord 1}

    pmRxPwrTpMaintAlarmClear  OBJECT-TYPE
        SYNTAX      INTEGER {
                             notActive   (0),
                             clear       (1)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object is used to clear the Perfomance Monitoring threshold cross alarms."
    ::= {pmRxPwrTpMaintRecord 2}
--
-------  End of pmRxPwrTpMaintTable

--
-------  The following objects are common to all radio branches.
--
    pmRxPwrTpClass15MRltsAlarmSeverityCode  OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Define the severity associated to the pmRxPwrTpClass15MRltsAlarm and
             enables/disables the trap generation on status change event."
        DEFVAL {majorTrapEnable}
    ::= {pmRxPwr 5}

    pmRxPwrTpClass24HRltsAlarmSeverityCode  OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Define the severity associated to the pmRxPwrTpClass24HRltsAlarm and
             enables/disables the trap generation on status change event."
        DEFVAL {majorTrapEnable}
    ::= {pmRxPwr 6}

------ End group -----------------------------------------------------------------