summaryrefslogtreecommitdiff
path: root/MIBS/sagemcom/PERFORMANCE-MIB
blob: f8674f3139ce9b76bdc5b94946cd32e80b8425cb (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
--*******************************************************************
--*    SAGEM, IONOS					 							    *
--*******************************************************************
--*******************************************************************

--
--  Filename: perf
--
--  File type: .mib    
-- 
--
--  Description:	SNMP source Mib file.
--
--			Describes performance records.
--             
--
--  Version:  19 11 2002
--	
--  Date(DD MM YYYY): 15 11 02 last update for IONOS NMS 
--     
--  Contact: D. Mobuchon, F. Bonnevialle
--
--  History: 
--		Version: 			Date: 25 10 1999
--		Version: MIB-P0-301199	Date: 30 11 1999 
-- 
--		Name: F.Bonnevialle 	
--		Date: 15 11 2002 		
--		Desc: Modification for SilverCreek Compiler
--*******************************************************************
--*******************************************************************
--*   Copyright (c) 2002, SAGEM , All rights reserved.              *
--*******************************************************************




--*******************************************************************
-- MIB: PERFORMANCE-MIB
--*******************************************************************
PERFORMANCE-MIB DEFINITIONS ::= BEGIN
 

--*******************************************************************
-- IMPORTS
--*******************************************************************
   IMPORTS
   sagemDr						FROM SAGEM-DR-MIB 
   IntDateTime						FROM EQUIPMENT-MIB
   MODULE-IDENTITY,OBJECT-TYPE,Gauge32,
   		NOTIFICATION-TYPE			FROM SNMPv2-SMI
   TimeTicks						FROM RFC1155-SMI
   DisplayString					FROM SNMPv2-TC ;
--   TRAP-TYPE						FROM RFC-1215;

 
   performance	MODULE-IDENTITY
      LAST-UPDATED "0211150000Z"
      ORGANIZATION "SAGEM/DR Tolbiac Centre"
      CONTACT-INFO
	" "
      DESCRIPTION 
	"     
	Modification: 
			Date: 15 11 2002
			Description: 
			sagemDr replace sagem-dr
			NOTIFICATION-TYPE replace TRAP-TYPE
	
	Modification: 
			Date: 20 12 1999	 
			Description: modification of comments
	Modification: 
			Date: 25 11 1999	 
			Name: thresholdUas,thresholdSes,thresholdEs,thresholdBbe
			Description: read-write instead of read-only
	Modification:
			Date: 19 11 1999
			Name: 
			Description: modification of comments		 
	Creation: 
			Date: 25 10 1999 
			Description: 
			The MIB module describes performance records.
			It also describes the traps that could be sent 
			either to notify a threshold or a non null quality 
			record, for the devices that support that feature.
	"
      ::= { sagemDr 102 }

--*******************************************************************

   NearFar     ::= INTEGER { near (1), far(2) }
   
   perfClear   OBJECT-TYPE
      SYNTAX       OBJECT IDENTIFIER
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"When a set command is issued on this variable, this clears a 
	part of the performance record depending on the value of the oid:
	performance	: all the performance records
	cptTable	: all the counter table
	uasTable	: all the unavailable periods table
	oid		: the counter and uas records of this object
	An equipment may implement only a subset of these commands."  
      ::= { performance 1 }
 
--*******************************************************************
-- Performance over the ports
-- This table contains the history of the quality counters 
-- When a Date is used as index the index value is MAXDate-Date 
-- to keep a lexicographic order.
   
   cptNumber   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of used records (rows) in 'cptTable'."  
      ::= { performance 2 } 

  
   cptTable   OBJECT-TYPE
      SYNTAX       SEQUENCE OF CptEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"List of cpt in equipment."  
      ::= { performance 3 } 
   
   cptEntry   OBJECT-TYPE
      SYNTAX       CptEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"A particular cpt of the equipment." 
      INDEX        { cptObject, cptNearFar, cptDuration, cptDate } 
      ::= { cptTable 1 } 

   CptEntry ::= SEQUENCE {
        cptObject   OBJECT IDENTIFIER,
	cptName     DisplayString,
        cptNearFar  NearFar,
        cptDuration TimeTicks,
        cptDate     IntDateTime,
        cptUAS      Gauge32,
        cptSES      Gauge32,
        cptES       Gauge32,
        cptBBE      Gauge32
      }
   
   
   cptObject   OBJECT-TYPE
      SYNTAX       OBJECT IDENTIFIER
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A reference to the function/interface from which this reccord
	was taken"  
      ::= { cptEntry 1 } 
   
   cptName   OBJECT-TYPE
      SYNTAX       DisplayString (SIZE (0..40))
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A text string which identifies the object localisation. For the 
	structure of this string, see 'logName' in the log MIB "  
      ::= { cptEntry 2 } 
   
   cptNearFar   OBJECT-TYPE
      SYNTAX       NearFar
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Indicates near or far performance record"  
      ::= { cptEntry 3 } 
   
   cptDuration   OBJECT-TYPE
      SYNTAX       TimeTicks
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"The full duration of measurement for the record.
	This table contains either logged entries and current ones.
	For curent performance counters, it is not the actual mesured
	duration, but the duration from start to normal end.
	The standard durations are 15 minutes and 24 hours; the value 
	can be coded in TimeTicks or  in minute (see the variable
	'perfDurationUnit')"  
      ::= { cptEntry 4 } 

   cptDate   OBJECT-TYPE
      SYNTAX       IntDateTime
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"When the record had started."  
      ::= { cptEntry 5 } 
   
   cptUAS   OBJECT-TYPE
      SYNTAX       Gauge32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of UnAvailable Seconds mesured."  
      ::= { cptEntry 6 } 
   
   cptSES   OBJECT-TYPE
      SYNTAX       Gauge32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of Severely Errored Seconds mesured."  
      ::= { cptEntry 7 } 
   
   cptES   OBJECT-TYPE
      SYNTAX       Gauge32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of Errored Seconds mesured."  
      ::= { cptEntry 8 } 
   
   cptBBE   OBJECT-TYPE
      SYNTAX       Gauge32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of Background Errors Blocks mesured."  
      ::= { cptEntry 9 }    


--*******************************************************************
-- Unavailable periods (uap)
-- This table contains the unavailable period records logged 
--by the system 
   
   
   uapNumber   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of unavailable period records stored in the 'uapTable'."  
      ::= { performance 4 } 
   
   uapTable   OBJECT-TYPE
      SYNTAX       SEQUENCE OF UapEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"List of unavailable period records in equipment."  
      ::= { performance 5 } 
   
   uapEntry   OBJECT-TYPE
      SYNTAX       UapEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"A particular unavailable period of the equipment." 
      INDEX        { uapObject, uapNearFar, uapBegin } 
      ::= { uapTable 1 } 

   UapEntry ::=
      SEQUENCE {
        uapObject   OBJECT IDENTIFIER,
	uapName     DisplayString,
        uapNearFar  NearFar,
        uapBegin    IntDateTime,
        uapEnd      IntDateTime
      }
   
   
   uapObject   OBJECT-TYPE
      SYNTAX       OBJECT IDENTIFIER
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A reference to the function/interface from witch this reccord
	was taken."  
      ::= { uapEntry 1 } 
   
   uapName   OBJECT-TYPE
      SYNTAX       DisplayString (SIZE (0..40))
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A text string which identifies the object localisation. For the 
	structure of this string, see 'logName' in the log MIB "  
      ::= { uapEntry 2 } 
   
   uapNearFar   OBJECT-TYPE
      SYNTAX       NearFar
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Indicates near or far performance record"  
      ::= { uapEntry 3 } 
   
   uapBegin   OBJECT-TYPE
      SYNTAX       IntDateTime
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"When the unavailable period has started."  
      ::= { uapEntry 4 } 
   
   uapEnd   OBJECT-TYPE
      SYNTAX       IntDateTime
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"When the unavailable period has finished."  
      ::= { uapEntry 5 }    



--*******************************************************************
-- Threshold values for performance threshold configuration
-- A record on this table contains the confuguration the threshold 
--    for a interface or a interface type 
-- This table must be initialized by the equipment during its restart
-- The write access authorization of this table is optional
   
   thresholdNumber   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of threshold in equipment."  
      ::= { performance 6 } 
   
   thresholdTable   OBJECT-TYPE
      SYNTAX       SEQUENCE OF ThresholdEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"List of threshold in equipment."  
      ::= { performance 7 } 
   
   thresholdEntry   OBJECT-TYPE
      SYNTAX       ThresholdEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"A particular threshold of the equipment." 
      INDEX        { thresholdObject, thresholdNearFar, 
				thresholdDuration, thresholdType } 
      ::= { thresholdTable 1 } 

   ThresholdEntry ::= SEQUENCE {
	thresholdObject   OBJECT IDENTIFIER,
	thresholdName     DisplayString,
        thresholdNearFar  NearFar,
        thresholdDuration TimeTicks,
        thresholdType   INTEGER,
	thresholdUas	INTEGER,
	thresholdSes	INTEGER,
	thresholdEs	INTEGER,
	thresholdBbe	INTEGER
   }
   
   
   thresholdObject   OBJECT-TYPE
      SYNTAX       OBJECT IDENTIFIER
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A reference to the interface or the interface type to which
	these parameters apply."  
      ::= { thresholdEntry 1 } 
   
   thresholdName   OBJECT-TYPE
      SYNTAX       DisplayString (SIZE (0..40))
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A text string which identifies the interface localisation. 
	For the structure of this string, see 'logName' in the 
	log MIB "  
      ::= { thresholdEntry 2 } 
   
   thresholdNearFar   OBJECT-TYPE
      SYNTAX       NearFar
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Indicates near or far performance threshold.
	Equipment may or may not implement far threshold."  
      ::= { thresholdEntry 3 } 
   
   thresholdDuration   OBJECT-TYPE
      SYNTAX       TimeTicks
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"The normal duration of the counter with which the threshold
	is associed. 
	The standard durations are 15 minutes and 24 hours; 
	"
      ::= { thresholdEntry 4 } 
   
   thresholdType   OBJECT-TYPE
      SYNTAX       INTEGER { raise(1), clear(2) }
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"When set to `raise' the event threshold exceded is generated 
	when one of the corresponding counter cross its theshold.
	When set to `clear', the event threshold exceded is cleared 
	when there is no counters above of its corresponding threshold.
	The `clear'thresholds are optionnal(the standard value is zero)
	"  
      ::= { thresholdEntry 5 } 
   

   thresholdUas   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
      "The number of unavailable seconds within a counting 
	period above which a performance event is issued 
	for the interface/function"  
      ::= { thresholdEntry 6 } 
   
   thresholdSes   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"The number of severely errored seconds within a 
	counting period above which a performance event 
	is issued for the interface/function"  
      ::= { thresholdEntry 7 } 
   
   thresholdEs   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
      "The number of errored seconds within a counting
	 period above which a performance event is issued 
	for the interface/function"  
      ::= { thresholdEntry 8 } 
   
   thresholdBbe   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
      "The number of background block errors within a
	counting period above which a performance event is
	issued for the interface/function"  
      ::= { thresholdEntry 9 }  


--   ***************************************************************
--   perfDurationUnit   OBJECT-TYPE
--      SYNTAX       INTEGER {timeTicks (1), minutes (2)}
--      MAX-ACCESS   read-only
--      STATUS       current
--      DESCRIPTION 
--	"Unit of the performance duration used in this MIB."  
--      ::= { performance 8 }  
--
--   *************************************************************** 
--   Performance enable variables 
--
--	The performance enables port by port are not in this MIB
--    The equipment can implement them in its proprietary MIB the 
--	performance .
--	Also the transmission quality status port by port are not 
--	in this MIb 
--    The equipment must implement them in its proprietary MIB 
--	the performance 


--   performanceEnable   OBJECT-TYPE
--      SYNTAX       SagemBoolean
--      MAX-ACCESS   read-only
--      STATUS       current
--      DESCRIPTION 
--	"
--	It is a global enable of the performance in the equipment
--	The default value of this variable is 'false'
--	"  
--      ::= { performance 9 }    

 
--   perfTrapEnable   OBJECT-TYPE
--      SYNTAX       SagemBoolean
--      MAX-ACCESS   read-only
--      STATUS       current
--      DESCRIPTION 
--	"
--	It is a global enable of the performance trap sending 
--	The default value of this variable is 'true'
--	"  
--     ::= { performance 10 }  

--   perfThresholdTrapEnable   OBJECT-TYPE
--      SYNTAX       SagemBoolean
--      MAX-ACCESS   read-only
--      STATUS       current
--      DESCRIPTION 
--	"
--	It is a global enable of the performance threshold overflow 
--	trap sending 
--	The default value of this variable is 'true'
--	"  
--      ::= { performance 11 }  


	  
--   ***************************************************************
   
--   qualityTrap TRAP-TYPE
--      ENTERPRISE  performance
--      VARIABLES   { cptObject, cptName, cptNearFar, 
--			cptDuration, cptDate, cptUAS, 
--			cptSES, cptES, cptBBE }
--      DESCRIPTION
--	" This trap allows the equipment to notify its quality records "
--	::= 2         
	
  perfTraps OBJECT IDENTIFIER ::= { performance 0 }
     
  qualityTrap NOTIFICATION-TYPE
          OBJECTS     { cptObject, cptName, cptNearFar, 
			cptDuration, cptDate, cptUAS, 
			cptSES, cptES, cptBBE }
          STATUS      current
          DESCRIPTION "This trap allows the equipment to notify its quality records"
          REFERENCE   ""
          ::= { perfTraps 2 }

END