summaryrefslogtreecommitdiff
path: root/MIBS/sagemcom/EQUIPMENT-MIB
blob: 9d46bddc992b30ce5a3340aeed869502b6c96c2b (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
--*******************************************************************
--*    SAGEM, IONOS 											    *
--*******************************************************************
--*******************************************************************
--
--  Filename: equip
--
--  File type: .mib    
-- 
--  Description:	SNMP source Mib file.
--
--			Contains general description and operation for
--			equipent level.
--             
--
--  Version:  19 11 2002
--	
--  Date(DD MM YYYY): 15 11 2002 last update for IONOS NMS 
--     
--  Contact: D. Mobuchon, F. Bonnevialle
--
--  History: 
--		Version: 			Date: 04 08 98
--		Version: MIB-P0-301199	Date: 30 11 1999
--      Version: MIB-P0-05092000 Date: 05 09 2000
--      Modification de la table des managers  
--
--		Name: S.LAURENT 	
--		Date: 25 04 2001 
--		Desc: * Add 7 equipment modification counters
--			   
--		Name: S.LAURENT 	
--		Date: 14 06 2002 
--		Desc: * DisplayString is imported from SNMPv2-TC instead of RFC1213
--          
--		Name: F.Bonnevialle 	
--		Date: 15 11 2002 		
--		Desc: Modification for SilverCreek Compiler
--*******************************************************************
--*******************************************************************
--*   Copyright (c) 2002, SAGEM , All rights reserved.              *
--*******************************************************************




--*******************************************************************
-- MIB: EQUIPMENT-MIB
--*******************************************************************
EQUIPMENT-MIB DEFINITIONS ::= BEGIN
 

--*******************************************************************
-- IMPORTS
--*******************************************************************

   IMPORTS
   sagemDr							FROM SAGEM-DR-MIB 
   MODULE-IDENTITY,
   		OBJECT-TYPE,
   		NOTIFICATION-TYPE,
		IpAddress,Counter32    		FROM SNMPv2-SMI
   DisplayString					FROM SNMPv2-TC;
--   TRAP-TYPE						FROM RFC-1215;
   



--*******************************************************************
-- OBJECTS
--*******************************************************************

--*******************************************************************

   equip	MODULE-IDENTITY
      LAST-UPDATED "0211150000Z"
      ORGANIZATION "SAGEM/DR Tolbiac Centre"
      CONTACT-INFO " "
      DESCRIPTION 
	"  
	Modification: 
			Date: 15 11 2002
			Description: 
			sagemDr replace sagem-dr
			NOTIFICATION-TYPE replace TRAP-TYPE
						
	Modification:
			Date: 14 06 2002
			Description: Modification of Imports
				DisplayString is imported from SNMPv2-TC instead of RFC1213				

	Modification:
			Date: 20 12 1999
			Description: Modification of comments
				Modification of bugs				
 
	Modification: 
			Date: 19 11 1999
			Name: sagem-dr, SagemBoolean
			Description: Definition of OID sagem-dr instead of sat      
				Definition of data SagemBoolean instead of Boolean 
	
			Name: communityString
			Description: SIZE(0..20) replaced by SIZE (0..50)


	New Object: 
			Date: 19 11 1999
		
			Name: All *Manager* are new objects
			Description: Manager list that recieves the traps.

			Name: equipCptModif
	 		Description: Incremental counter used to manage 
				the modifications	on the equipment.

	 		Name: communityAcces
	 		Description: new names used
				iONNOS-ANM-Supervisor instead of Set ...	

			Name: trapCommunity
			Description:SIZE(0..20) replaced by SIZE (0..50)

			Name: equipLoad
	 		Description: Object is simplified to an OID 
   
			Name: equipLoadDiagnostic
	 		Description: A string to help in case of problem  

			Name: transferedItemTable,transferedItem,
				TransferedItem,transferedItemIndex
				transferedItemType,transferedItemVersion
				transferedItemComments
	 		Description:
			These object are used to manage the download 
			and upload of some part of the data; the data
			can be a part of a program, a complete program,
			or a config.
			The transferedItemType is reused in equipLocalFile

	 		Name: equipStatusV2
			Description: used by IONOS ANM V2      

	"
      REVISION "9808040000Z"
      DESCRIPTION 
	"
	Creation : this MIB module describes equipment level operation such as
	date and time set, restart, reset, community and trap  
	management.
	"	
	      ::= { sagemDr 107 }

--*******************************************************************

SagemBoolean  ::= INTEGER { true(1), false(2) }
IntDateTime ::= INTEGER (0..2147483647) 
Severity    ::= INTEGER
      { 
		nonAlarmed (1), 
		minor (2), 
		major (3), 
		critical (4), 
		warning (5),
		invNonAlarmed (6),
		invMinor(7),
    	invMajor(8),
    	invCritical(9),
    	invWarning(10) 
	}


--*******************************************************************
   equipDateTime   OBJECT-TYPE
      SYNTAX       IntDateTime
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
      "The value of this field is the date and time of the equipment.
	It is the number of seconds since 1st January 1970."  
      ::= { equip 1 } 
   
   equipLastModif   OBJECT-TYPE
      SYNTAX       IntDateTime
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The date and time when the equipment was last modified."           
      ::= { equip 2 } 

   equipWarmStart   OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"The equipment make a hot start if this field is set to `true'.
	This operation can only be done by the iONOSANMsupervisor
	or dIRECTACCESSsupervisor. 
	The value returns to `false' after the restart."  
      ::= { equip 3 } 
   
   equipClearConf   OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"The equipment resets all its parameters, including those 
	stored in non-volatile media storage, if this field is set 
	to `true'.
	This command does not apply to mib-2 parameters, like @ip, 
	routing table, etc ...
	This operation can only be done by the iONOSANMsupervisor
	or dIRECTACCESSsupervisor. 
	The value returns to `false' after the reset.
	This operation is optionnal."  
      ::= { equip 4 } 
   
 
--*******************************************************************
-- Description:
--		Community 
--		 The "communityTable" is used for the habilitation.
--		It contains a sequense of "CommunityEntry" 
-- 		The size for the habilitation table is 10 elements for ADR equipement.
--		 A "CommunityEntry" is a sequence:
--		(communityIndex,communityString,communityAccess)
--		 The different kind of habilitation are:
--		iONOSANMobserver,
--		iONOSANMoperator,
--		iONOSANMsupervisor,
--		dIRECTACCESSobserver,
--		dIRECTACCESSoperator,
--		dIRECTACCESSsupervisor,
-- The 4 last one are used for the "Add Drop for IP" IPA.
--		iONOSANMclientobserver,
--		iONOSANMclientoperator,
--		dIRECTACCESSclientobserver,
--		dIRECTACCESSclientoperator.

   communityNumber   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of community in equipment."  
      ::= { equip 5 } 
   
   communityTable   OBJECT-TYPE
      SYNTAX       SEQUENCE OF CommunityEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"List of community in equipment."  
      ::= { equip 6 } 
   
   communityEntry   OBJECT-TYPE
      SYNTAX       CommunityEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"A particular community of the equipment." 
      INDEX        { communityIndex } 
      ::= { communityTable 1 } 

   CommunityEntry ::=
      SEQUENCE {
        communityIndex         INTEGER,
        communityString        DisplayString,
        communityAcces         INTEGER
      }
   
   communityIndex   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A unique value which identify a particular
	community."
      ::= { communityEntry 1 } 

 
  communityString   OBJECT-TYPE
      SYNTAX       DisplayString 
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"A unique textual string that can be used by a SNMP manager as
	community string. It can be also used as password for other
	configuration like http, not only snmp.
	The table must have at least two entries associated with 
	the iONOSANMsupervisor access right (this entry is created by 
	equipement at startup with value `secret') and 
	dIRECTACCESSsupervisor access right (this entry is 	
	created by equipement	at startup  with value 'supervisor') . 
	According to equipment implementation, it is possible to 
	create other entries associed with lower rights that PDU 
	community string can afford (actualy equal if 
	IONOSANMsupervisor status is granted).
	If the other access rights are created at startup by the equipment,
	 its must use the following values : 'private' for 
	'iONOSANMoperator, 'public' for 'iONOSANMobserver', 
	 'operator' for dIRECTACCESSoperator, 'observer' for 
	dIRECTACCESSobserver, and 'client' for the others.
	
	All community string can be modified only by 
	IONOSANMsupervisor.
	A dIRECTACCESS community string can be modified by 
	dIRECTACCESSsupervisor.
	
	The reading of a community string gives *** for all 
	access rights .
	
	An entry may be discarded by setting its community string to 
	void string. This should not be used by the administrator or 
	he could discard himself "  

      ::= { communityEntry 2 }


   communityAcces   OBJECT-TYPE
      SYNTAX        INTEGER {iONOSANMobserver (1), 
                             iONOSANMoperator(2), 
                             iONOSANMsupervisor(3), 
				     		 dIRECTACCESSobserver (4),
                             dIRECTACCESSoperator(5), 
                             dIRECTACCESSsupervisor(6), 
                             iONOSANMclientobserver(7),
                             iONOSANMclientoperator(8),
                             dIRECTACCESSclientobserver(9),
                             dIRECTACCESSclientoperator(10)
				    }

      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"
	iONOSANMsupervisor(3) access :
		allows all operations including community string
		(community string = password)
	iONOSANMoperator(2) access :
		allows all set operations except write community
	   	string read or write and also some special operations.
	iONOSANMobserver (1) access : 
		allows only get and get_next requests.
	dIRECTACCESSsupervisor(6) access : 
		allows all operations EXcluding IONOS ANM community string
	dIRECTACCESSoperator(5) access :
		allows all set operations except write community
	   	string read or write and also some special operations.
	dIRECTACCESSobserver (4) access :
		allows only get and get_next requests.		
      iONOSANMclientoperator(8) access :                      
		allows only set some special operations 
      iONOSANMclientobserver(7) access :
		allows only get and get_next requests for special operations 
      dIRECTACCESSclientoperator(10) access :                      
		allows only set some special operations 
	dIRECTACCESSclientobserver(9) access :
		allows only get and get_next requests for special operations 
      "
     ::= { communityEntry 3 }    


--*******************************************************************
-- Description:
--		"trapTable": trap's receiver table  	

   trapNumber   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of trap receivers description in equipment."  
      ::= { equip 7 } 
   
   trapTable   OBJECT-TYPE
      SYNTAX       SEQUENCE OF TrapEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"List of trap receivers in equipment."  
      ::= { equip 8 } 
   
   trapEntry   OBJECT-TYPE
      SYNTAX       TrapEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"A particular trap of the equipment." 
      INDEX        { trapIndex } 
      ::= { trapTable 1 } 
  
  TrapEntry ::=
      SEQUENCE {
	  trapIndex              INTEGER,
        trapDestination        IpAddress,
        trapCommunity          DisplayString
      }
   
  trapIndex   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A unique value which identify a particular
	trap receiver.
	The value of index is a constant assigned to an entry at
	equipment design time. "  
      ::= { trapEntry 1 } 
   
   trapDestination   OBJECT-TYPE
      SYNTAX       IpAddress
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"The ip address to which the equipment will send the traps. 
	Note that the value must be unique along this table.
	An entry may be discarded by setting the IP address to 0.0.0.0
	" 
      ::= { trapEntry 2 } 
   
     
   trapCommunity   OBJECT-TYPE
      SYNTAX       DisplayString 
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
--	It is better to use a size value lower than 10.
--	The size value 50 is used for the BMX
	"The community string to use when a trap is sent to 
	this address. "  
      ::= { trapEntry 3 }    



--*******************************************************************

-- Description: 
--		Up and download for the software and configuration
-- 
   equipLoad   OBJECT IDENTIFIER ::= { equip 9 }
      
   equipLocalFile   OBJECT-TYPE
      SYNTAX       DisplayString       
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"The file path suitable for the equipment."  
      ::= { equipLoad 1 } 
   
   equipServerAddress   OBJECT-TYPE
      SYNTAX       IpAddress
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"The ip adress of tftp serveur from which is read/write 
	the file `equipRemoteFile'."  
      ::= { equipLoad 2 } 
   
   equipRemoteFile   OBJECT-TYPE
      SYNTAX       DisplayString 
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"The file path to be loaded on/from the equipement."  
      ::= { equipLoad 3 } 
   
   equipDirection   OBJECT-TYPE
      SYNTAX       INTEGER { download (0), upload(1)
			, backupDownload (2), switching (3)
	}
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"This field selects the direction of data stream.
	When it is set to `backupDownload', only the transfert is done.
	When it is set to `download' the transfert is done and then the 
	information transfert is switched in the operational state.
	When it is set to `switching', there is no transfert; 
	there is only  a switching. "     
      ::= { equipLoad 4 } 

   equipLoadProceed   OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"
	This entry is use to start (set to `true') loading a file 
	on/from a equipment which has a tftp client.
	The value of the field remains to `true' until load is 
	completed or has been aborted.
	This operation can only be done by the iONOSANMsupervisor
	or dIRECTACCESSsupervisor.
	It may be possible to abort the loading by setting it 
	to false.
	After the switching of a new configuration, the equipment
	must increase the value of the variable 'equipCptModif' 
	"  
      ::= { equipLoad 5 } 
   
   equipLoadDiagnostic   OBJECT-TYPE
      SYNTAX       DisplayString 
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A string used to help in case of trouble."  
      ::= { equipLoad 6 }  
   
   equipLoadProtocole   OBJECT-TYPE
      SYNTAX       INTEGER { ftp (1), tftp (2), 
						http (3), telnet (4)}
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Protocole used by the equipment for the download"  
      ::= { equipLoad 7 }  


--*******************************************************************
-- Description: 
--		Delayed up and download for the software and configuration
--
--   equipLoadState   OBJECT-TYPE
--      SYNTAX       INTEGER { delayedLoad (1), loadRunning (2), 
--					delayedSwitching (3), switchingRunning (4),
--					loadOK (5), loadNOK (6) ,aborted (7)}
--      MAX-ACCESS   read-only
--      STATUS       current
--      DESCRIPTION 
--	"This field indicates the status of the current load processes valided 
--	by 'equipLoadProceed'.
--      Remark : a download includes a data transfer (load) from the 
--	server to the equipment and a switching for using the data or the 
--	software transfered . A upload includes only a data transfer from 
--	the equipment to the server
--	It's optional for the equipment which doesn't realise delayed download "
--	::= { equipLoad 8 } 
--
--	equipLoadDateTime   OBJECT-TYPE
--      SYNTAX       IntDateTime
--      MAX-ACCESS   read-write
--      STATUS       current
--      DESCRIPTION 
--      "The value of this field is the date and time of the equipment 
--	at which the load processes valided by 
--	'equipLoadProceed' must begin .
--	If this value if equal at 0 or < at the current
--	time, the load starts immediately.
--	It is the number of seconds since 1st January 1970."  
--	::= { equipLoad 9 }
--
--	equipSwitchingDateTime   OBJECT-TYPE
--      SYNTAX       IntDateTime
--      MAX-ACCESS   read-write
--      STATUS       current
--      DESCRIPTION 
--      "
--	The value of this field is the date and time of the equipment
--	at which the switching processes valided by 
--	'equipLoadProceed' must begin .If this value if equal at
--	0 or < at the current time, the switching starts immediately 
--	(if there isn't load)or immediately after the load (if there is a load).
--	It is the number of seconds since 1st January 1970.
--	After the switching of a new configuration, the equipment
--	must increase the value of the variable 'equipCptModif' 
--	"  
--	::= { equipLoad 10 } 
--


--*******************************************************************
-- Description:
--		These object are used to manage the download 
--		and upload of some part of the data; the data
--		can be a part of a program, a complete program,
--		or a config.
--			
--		The transferedItemType can be:
--			inactive programName 
--			active programName 
--			inactive"Config"
--			active"Config"
--			ALL Program
--			ALL
--
--		The transferedItemType is reused in equipLocalFile   


  transferedItemTable   OBJECT-TYPE
      SYNTAX       SEQUENCE OF TransferedItemEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"List of uploaded or downloaded Item from the 
	equipment."  
      ::= { equip 30 } 
   
   transferedItemEntry   OBJECT-TYPE
      SYNTAX       TransferedItemEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"A particular Item transferd from/to the equipment." 
      INDEX        { transferedItemIndex } 
      ::= { transferedItemTable 1 } 

   TransferedItemEntry ::=
      SEQUENCE {
        transferedItemIndex         INTEGER,
        transferedItemType          DisplayString,
	  transferedItemVersion       DisplayString,
	  transferedItemComment       DisplayString  	
      }
   
   transferedItemIndex   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	""  
      ::= { transferedItemEntry 1 } 
   
   transferedItemType   OBJECT-TYPE
      SYNTAX       DisplayString 
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"used to know what kind of data to transferate,
	mainly programName or config"
      ::= { transferedItemEntry 2 }

   transferedItemVersion   OBJECT-TYPE
      SYNTAX       DisplayString 
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"for a program, return the software version;
	for a config return the associated software version"
      ::= { transferedItemEntry 3 }

   transferedItemComment   OBJECT-TYPE
      SYNTAX       DisplayString
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"give additional information about the tranfered data"
      ::= { transferedItemEntry 4 }

--*******************************************************************
-- Description:

   equipStatus   OBJECT-TYPE
      SYNTAX       Severity
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"This field summerizes the status of all equipment objects 
	(port, card, ...)
	This variable is polled by IONOS ANM V1
	The 'equipmentStatusTrap' is sent after a GET on this variable.
	equipStatus and equipStatusTrap are only used with V1. 
	"
      ::= { equip 10 } 

   equipStatusV2   OBJECT-TYPE
      SYNTAX       Severity
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Replace equipStatus for the v2. For the v1, equipStatus 
	in EQUIPMENT-MIB send a trap after been polled; 
	For the v2, equipStatus is polled."  
      ::= { equip 11 } 

--*******************************************************************
--*   modification counters
--*******************************************************************
-- Description:
--		"equipCptModif":
--			Incremental counter used to manage the modifications
--			on the equipment.
-- Warning:
--		Replace equipLastModif for the new equipment ADR155c and 
--		the next generation of equipment. 

   equipCptModif   OBJECT-TYPE
      SYNTAX       Counter32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The counter for all equipments modifications. It represents
        the sum of the 7 other counters"  
      ::= { equip 12 } 
 
   -- Modification counters
  cptModif	 		OBJECT IDENTIFIER ::= { equip 14 }
 
    cptSNC   OBJECT-TYPE
      SYNTAX       Counter32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The counter version for the SNC modifications."  
      ::= { cptModif 1 } 
     
      
    cptCnx   OBJECT-TYPE
      SYNTAX       Counter32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The counter version for the Connexion modifications."  
      ::= { cptModif 2 } 
 
    cptMSP   OBJECT-TYPE
      SYNTAX       Counter32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The counter version for the MSP modifications."  
      ::= { cptModif 3 } 

    cptMsSpring   OBJECT-TYPE
      SYNTAX       Counter32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The counter version for the MS-SPRING modifications."  
      ::= { cptModif 4 } 

    cptSynchro   OBJECT-TYPE
      SYNTAX       Counter32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The counter version for the Synchro modifications."  
      ::= { cptModif 5 } 

    cptMngt  OBJECT-TYPE
      SYNTAX       Counter32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The counter version for the MNGT modifications (mngt list, password, trap, ...)."  
      ::= { cptModif 6 } 

    cptNet   OBJECT-TYPE
      SYNTAX       Counter32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The counter version for the Network modifications."  
      ::= { cptModif 7 } 
     

-- equipConfSaveStatus   OBJECT-TYPE
--      SYNTAX       SagemBoolean
--      MAX-ACCESS   read-only
--      STATUS       current
--      DESCRIPTION 
--	"If 'true', this variable indicates that all configuration
-- 	modifications are saved in flash memory. 
--	If false, this variable indicates that configuration 
--	modifications are not saved in flash memory. "  
--      ::= { equip 13 }


--*******************************************************************
--
-- Description:
-- 			ACCESS TABLE FILTER
--		The table is a access filter table that ckeck the IP address of 
--		the SNMP managers.


   equipManagerNumber   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of manager = number of IP addresses in the table"  
      ::= { equip 20 } 

   equipManagerTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF EquipManagerEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION
	"Table containing Ip Addresses and maximum authorized level"
	::= { equip 21 }
	
   equipManagerEntry OBJECT-TYPE
	SYNTAX  EquipManagerEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION
	"Entry containing IP addresses of managers allowed in R/W."
	INDEX   {equipManagerIndex}
	::= {equipManagerTable 1}
	
   EquipManagerEntry ::=
	SEQUENCE        
		{
			equipManagerIndex INTEGER,        
			equipManagerAddress IpAddress,
			equipManagerADM SagemBoolean,
			equipManagerOPR SagemBoolean,
			equipManagerOBS SagemBoolean
		}
	
   equipManagerIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..2147483647) 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"Index of equipManagerTable
	There's only 10 values in this table"
	::= {equipManagerEntry 1}
	
   equipManagerAddress OBJECT-TYPE
	SYNTAX  IpAddress
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
	"The IP address of one of the allowed managers.
   	If the table contains only address values which are equal
  	 to 0.0.0.0, no access filter are done.
   	Write the IP address 0.0.0.0 to remove a manager.
	This operation can only be done by the iONOSANMsupervisor.
	" 
	::= {equipManagerEntry 2}

   equipManagerADM   OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"If 'true', this variable indicates that the manager defined by 
	its address can have  the Supervisor rigth as maximum level
	The value 'false' is set by the equipment when another level 
	is choosen"  
      ::= {equipManagerEntry 3}
 	
   equipManagerOPR   OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"If 'true', this variable indicates that the manager defined by 
	its address can have  the Operator rigth as maximum level
	The value 'false' is set by the equipment when another level 
	is choosen"  
      ::= {equipManagerEntry 4}

  equipManagerOBS   OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"If 'true', this variable indicates that the manager defined by 
	its address can have the Observer rigth as maximum level
	The value 'false' is set by the equipment when another level 
	is choosen"  
      ::= {equipManagerEntry 5}

--*******************************************************************
-- Warning: This Trap is only used for V1
--  equipStatusTrap  TRAP-TYPE
--   	ENTERPRISE  equip
--  	VARIABLES   { equipStatus }
--  	DESCRIPTION
--	"This trap indicates the alarm status of the equipment.
--	Only sent with IONOS ANM V1"
--      ::= 1
  
  equipTraps OBJECT IDENTIFIER ::= { equip 0 }
     
  equipStatusTrap NOTIFICATION-TYPE
          OBJECTS     { equipStatus }
          STATUS      current
          DESCRIPTION "This trap indicates the alarm status of the equipment.
						Only sent with IONOS ANM V1"
          REFERENCE   ""
          ::= { equipTraps 1 }
END