1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
|
SAF-INTEGRAW-MIB DEFINITIONS ::= BEGIN
-- Definitions for include by other SAF Tehnika mib modules
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32, Counter64,
TimeTicks
FROM SNMPv2-SMI -- [RFC2578]
pointToPoint
FROM SAF-ENTERPRISE
safIntegra
FROM SAF-INTEGRA-MIB
DisplayString, DateAndTime, PhysAddress
FROM SNMPv2-TC
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF -- [RFC2580]
IpAddress
FROM SNMPv2-SMI -- [RFC2578]
IANAifType
FROM IANAifType-MIB;
-- saf OBJECT IDENTIFIER ::= { enterprises 7571 }
-- microwaveRadio OBJECT IDENTIFIER ::= { tehnika 1 }
-- pointToPoint OBJECT IDENTIFIER ::= { microwaveRadio 1 }
-- safIntegra OBJECT IDENTIFIER ::= { pointToPoint 7 }
integraW MODULE-IDENTITY
LAST-UPDATED "201605110000Z" -- 11 may 2016
ORGANIZATION "SAF Tehnika"
CONTACT-INFO
"SAF Tehnika technical support
<techsupport>"
DESCRIPTION
"SAF IntegraW radio management base"
-- Revision history
REVISION "201605110000Z" -- 11 may 2016
DESCRIPTION
"Rx Level State added"
REVISION "201509170000Z" -- 17 sep 2015
DESCRIPTION
"Conformance updated"
REVISION "201509150000Z" -- 15 sep 2015
DESCRIPTION
"Local/remote IP address, mask, gateway OIDs added"
REVISION "201508120000Z" -- 12 aug 2015
DESCRIPTION
"Syntax error fixes"
REVISION "201507290000Z" -- 29 jul 2015
DESCRIPTION
"No modem distortion data is available on Integra-W"
REVISION "201505290000Z" -- 29 may 2015
DESCRIPTION
"No carrier offset and modem temp. data are available on Integra-W"
REVISION "201505200000Z" -- 20 may 2015
DESCRIPTION
"Public Release 1.04.
Radio PLL status, free physical memory, CPU idle objects added"
REVISION "201504210000Z" -- 21 apr 2015
DESCRIPTION
"Public Release 1.03.
Added OIDs for modem signal quality and distortion"
REVISION "201504140000Z" -- 14 apr 2015
DESCRIPTION
"Descriptions updated"
REVISION "201503240000Z" -- 24 mar 2015
DESCRIPTION
"Public Release 1.02.
Removed integraWifLinkUpDownTrapEnable OID"
REVISION "201502040000Z" -- 04 feb 2015
DESCRIPTION
"Syntax fix for integraWmodemRadialMse"
REVISION "201501200000Z" -- 20 jan 2015
DESCRIPTION
"Small typographic error fix"
REVISION "201501080000Z" -- 08 jan 2015
DESCRIPTION
"Public Release 1.01. Syntax & units fixed"
REVISION "201501060000Z" -- 06 jan 2015
DESCRIPTION
"Public Release 1.0"
::= { safIntegra 2 }
integraWtimestamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Last data update time"
::= { integraW 1 }
-- radio
integraWradio OBJECT IDENTIFIER ::= { integraW 2 }
integraWradioTxPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Output power of radio transmitter"
::= { integraWradio 1 }
integraWradioTxFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Frequency of radio transmitter"
::= { integraWradio 2 }
integraWradioRxLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Level of the received signal"
::= { integraWradio 3 }
integraWradioSide OBJECT-TYPE
SYNTAX INTEGER {
high(1),
low(2),
error(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Radio side: Low/High"
::= { integraWradio 4 }
integraWradioTxMute OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2),
error(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of 'Tx mute'
1 - Tx is muted,
2 - Tx is not muted.
3 - Status information unavailable"
::= { integraWradio 5 }
integraWradioDuplexShift OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Utilized duplex shift in kHz"
::= { integraWradio 6 }
integraWradioRxFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Frequency of radio receiver"
::= { integraWradio 7 }
integraWradioTemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Radio module temperature *10 Celsius"
::= { integraWradio 8 }
integraWradioTxMuteDuration OBJECT-TYPE
SYNTAX Integer32(0..214748364)
UNITS "s"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time remaning for Tx to be muted in seconds.
To turn mute on send number of seconds between 10 and MAX.
To turn mute off send 0.
GET will retrieve remaining duration for mute or
0 if Tx mute is turned off."
::= { integraWradio 9 }
--Settable radio parameter range values
integraWradioRangesTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntegraWradioRangeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Network interface port status data."
::= { integraWradio 10 }
integraWradioRangeEntry OBJECT-TYPE
SYNTAX IntegraWradioRangeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing network physical port status info."
INDEX { integraWradioRangeEntryIndex }
::= { integraWradioRangesTable 1 }
IntegraWradioRangeEntry ::=
SEQUENCE {
integraWradioRangeEntryIndex
Integer32,
integraWradioRangeDescr
DisplayString,
integraWradioRangeTxPower
Integer32,
integraWradioRangeTxFrequency
Integer32
}
integraWradioRangeEntryIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each range
entry. Starts with 1 and is equal to a number of all range
parameters."
::= { integraWradioRangeEntry 1 }
integraWradioRangeDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"'Minimal' and 'maximal' labels"
::= { integraWradioRangeEntry 2 }
integraWradioRangeTxPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Output power ranges for integraWradio transmitter"
::= { integraWradioRangeEntry 3 }
integraWradioRangeTxFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Frequency ranges for integraWradio transmitter"
::= { integraWradioRangeEntry 4 }
integraWradioPLL OBJECT-TYPE
SYNTAX INTEGER {
error(1),
ok(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "PLL state of local-oscillator generator"
::= { integraWradio 11 }
integraWradioRxLevelState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
low(2),
high(3),
error(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Received signal level state"
::= { integraWradio 12 }
-- modem
integraWmodem OBJECT IDENTIFIER ::= { integraW 3 }
-- modem-status
-- modem-config
-- misc
integraWmodemAcquireStatus OBJECT-TYPE
SYNTAX INTEGER {
acquireInProgress(1),
acquireLocked(2),
acquireFailed(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the current status of modem data acquire
when queried modem status.
For detailed info use modemAcquireLastStatusDetails."
::= { integraWmodem 1 }
integraWmodemMse OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current MSE value (floating point value multiplied by 10)"
::= { integraWmodem 2 }
-- ldpcDecoderStress OBJECT-TYPE
integraWmodemFecLoad OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Decoder stress or FEC load value (floating point in textual representation)"
::= { integraWmodem 3 }
integraWmodemSyncLoss OBJECT-TYPE
SYNTAX INTEGER {
locked(1),
unlocked(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem synchronization status"
::= { integraWmodem 4 }
-- integraWmodemTemperature OBJECT-TYPE
-- SYNTAX Integer32
-- UNITS "C"
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION "Modem DSP temperature *10 Celsius"
-- ::= { integraWmodem 5 }
integraWmodemBandwidth OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Signal bandwidth"
::= { integraWmodem 6 }
integraWmodemModulation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modulation (preferred)"
::= { integraWmodem 7 }
integraWmodemRxModulation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current (actual) Rx Modulation"
::= { integraWmodem 8 }
integraWmodemTxModulation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current (actual) Tx Modulation"
::= { integraWmodem 9 }
integraWmodemRxCapacity OBJECT-TYPE
SYNTAX Integer32
UNITS "kb/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Rx ethernet capacity in kilobits per second"
::= { integraWmodem 10 }
integraWmodemTxCapacity OBJECT-TYPE
SYNTAX Integer32
UNITS "kb/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Tx ethernet capacity in kilobits per second"
::= { integraWmodem 11 }
integraWmodemAcmEngine OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
error(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "ACM engine status"
::= { integraWmodem 12 }
-- integraWmodemCarrierOffset OBJECT-TYPE
-- SYNTAX Integer32
-- UNITS "Hz"
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION "Modem carrier offset"
-- ::= { integraWmodem 13 }
integraWmodemSignalQuality OBJECT-TYPE
SYNTAX Integer32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem signal quality in %"
::= { integraWmodem 14 }
-- integraWmodemDistortion OBJECT-TYPE
-- SYNTAX Integer32
-- UNITS "%"
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION "Modem distortion in %"
-- ::= { integraWmodem 15 }
-- system
integraWsystem OBJECT IDENTIFIER ::= { integraW 4 }
integraWsysCPUtemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "System CPU temperature *10 Celsius"
::= { integraWsystem 2 }
integraWsysLicenseExpire OBJECT-TYPE
SYNTAX Gauge32
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "License expires after number of seconds.
In the case of -1, check licenseGenStatus status"
::= { integraWsystem 3 }
integraWsysLicenseGenStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
expired(2),
unknown(3),
unlimitedTime(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "License General status."
::= { integraWsystem 4 }
integraWsysPSUvoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "mV"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Power voltage in mV"
::= { integraWsystem 5 }
integraWsysPSUcurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Power current in mA"
::= { integraWsystem 6 }
integraWsysPSUpower OBJECT-TYPE
SYNTAX Integer32
UNITS "mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Power consumption in mW"
::= { integraWsystem 7 }
integraWsysBoardTemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "System temperature *10 Celsius"
::= { integraWsystem 8 }
integraWsysFreeMemory OBJECT-TYPE
SYNTAX Integer32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "System free memory *10 %"
::= { integraWsystem 9 }
integraWsysCPUidle OBJECT-TYPE
SYNTAX Integer32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "System CPU idle *10 %"
::= { integraWsystem 10 }
-- Ethernet
integraWethernet OBJECT IDENTIFIER ::= { integraW 5 }
-- Port status
integraWifStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntegraWifPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Network interface port status data."
::= { integraWethernet 1 }
integraWifPortEntry OBJECT-TYPE
SYNTAX IntegraWifPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing network physical port status info."
INDEX { integraWifPortStatIndex }
::= { integraWifStatusTable 1 }
IntegraWifPortEntry ::=
SEQUENCE {
integraWifPortStatIndex
Integer32,
integraWifPortStatDescr
DisplayString,
integraWifPortType
IANAifType,
integraWifPortMtu
Integer32,
integraWifPortSpeed
Gauge32,
integraWifPortPhysAddress
PhysAddress,
integraWifPortAdminStatus
INTEGER,
integraWifPortOperStatus
INTEGER,
integraWifPortLastChange
TimeTicks,
integraWifPortAutoneg
INTEGER,
integraWifPortDuplex
INTEGER,
integraWifPortSyncEthActive
INTEGER,
integraWifPortSyncEthPrio
Integer32,
integraWifPortFlowControl
INTEGER
}
integraWifPortStatIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each physical
network interface. It is recommended that
values are assigned contiguously starting from 1."
::= { integraWifPortEntry 1 }
integraWifPortStatDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical network interface description.
LAN1 is electrical, LAN2 and LAN3 are SFP
and WAN is radio port."
::= { integraWifPortEntry 2 }
integraWifPortType OBJECT-TYPE
SYNTAX IANAifType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of interface, distinguished according to
the physical/link protocol(s) immediately `below'
the network layer in the protocol stack."
::= { integraWifPortEntry 3 }
integraWifPortMtu OBJECT-TYPE
SYNTAX Integer32
UNITS "B"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum transmission unit value in bytes."
::= { integraWifPortEntry 4 }
integraWifPortSpeed OBJECT-TYPE
SYNTAX Gauge32
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link speed in bits per second."
::= { integraWifPortEntry 5 }
integraWifPortPhysAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface's address at the protocol layer
immediately `below' the network layer in the
protocol stack. For interfaces which do not have
such an address (e.g., a serial line), this object
should contain an octet string of zero length."
::= { integraWifPortEntry 6 }
integraWifPortAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Desired state of network interfaces. Interfaces
can be enabled(1), disabled(2), unknown(3) (no info received)."
::= { integraWifPortEntry 7 }
integraWifPortOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual state of interfaces. Link can be up(1),
down(2) or in unknown(3) state."
::= { integraWifPortEntry 8 }
integraWifPortLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter value is always 0 at the moment."
::= { integraWifPortEntry 9 }
integraWifPortAutoneg OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Auto-negotiation status. Unknown means no info was received."
::= { integraWifPortEntry 10 }
integraWifPortDuplex OBJECT-TYPE
SYNTAX INTEGER {
full(1),
half(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Duplex status for the interface."
::= { integraWifPortEntry 11 }
integraWifPortSyncEthActive OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Synchronous Ethernet status.
Can be active(1) or inactive(0)."
::= { integraWifPortEntry 12 }
integraWifPortSyncEthPrio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Synchronous Ethernet priority."
::= { integraWifPortEntry 13 }
integraWifPortFlowControl OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Flow control status."
::= { integraWifPortEntry 14 }
-- Port statistics
integraWifStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntegraWifPortStcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Network interface port statistics data."
::= { integraWethernet 2 }
integraWifPortStcEntry OBJECT-TYPE
SYNTAX IntegraWifPortStcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing network physical port statistics counter data."
INDEX { integraWifPortStcIndex }
::= { integraWifStatisticsTable 1 }
IntegraWifPortStcEntry ::=
SEQUENCE {
integraWifPortStcIndex
Integer32,
integraWifPortStcDescr
DisplayString,
integraWifTimePassed
TimeTicks,
integraWrxDetected
Counter64,
integraWrxDropped
Counter64,
integraWtxDetected
Counter64,
integraWtxDropped
Counter64,
integraWrxBytes
Counter64,
integraWtxBytes
Counter64,
integraWrx64Frames
Counter64,
integraWrx65to127Frames
Counter64,
integraWrx128to255Frames
Counter64,
integraWrx256to511Frames
Counter64,
integraWrx512to1023Frames
Counter64,
integraWrx1024toMaxFrames
Counter64,
integraWrxUsizeFrames
Counter64,
integraWrxOsizeFrames
Counter64,
integraWtx64Frames
Counter64,
integraWtx65to127Frames
Counter64,
integraWtx128to255Frames
Counter64,
integraWtx256to511Frames
Counter64,
integraWtx512to1023Frames
Counter64,
integraWtx1024toMaxFrames
Counter64,
integraWtxUsizeFrames
Counter64,
integraWtxOsizeFrames
Counter64,
integraWrxGoodFrames
Counter64,
integraWrxErrors
Counter64,
integraWrxFifoErr
Counter64,
integraWrxCRCErrors
Counter64,
integraWrxBcastFrames
Counter64,
integraWrxMcastFrames
Counter64,
integraWrxCntrlFrames
Counter64,
integraWrxLenErrors
Counter64,
integraWrxVlanFrames
Counter64,
integraWrxPauseFrames
Counter64,
integraWrxOpErrors
Counter64,
integraWrxFrameErrors
Counter64,
integraWtxGoodFrames
Counter64,
integraWtxErrors
Counter64,
integraWtxFifoErr
Counter64,
integraWtxBcastFrames
Counter64,
integraWtxMcastFrames
Counter64,
integraWtxUrunErrors
Counter64,
integraWtxCntrlFrames
Counter64,
integraWtxVlanFrames
Counter64,
integraWtxPauseFrames
Counter64,
integraWtxSingleCollisions
Counter64,
integraWtxMultiCollisions
Counter64,
integraWtxDeferred
Counter64,
integraWtxLateCollisions
Counter64,
integraWtxExcessCollisions
Counter64,
integraWtxExcessDeferral
Counter64,
integraWtxAlignErrors
Counter64,
integraWtxCarrierErrors
Counter64,
integraWtxCollisions
Counter64
}
integraWifPortStcIndex OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each physical
network interface. It is recommended that
values are assigned contiguously starting from 1."
::= { integraWifPortStcEntry 1 }
integraWifPortStcDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical network interface description.
LAN1 is electrical, LAN2 and LAN3 are SFP,
WAN is radio port and MNG is internal management interface."
::= { integraWifPortStcEntry 2 }
integraWifTimePassed OBJECT-TYPE
SYNTAX TimeTicks
UNITS "s/100"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Statistics collection time."
::= { integraWifPortStcEntry 3 }
integraWrxDetected OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Detected ingoing packets counter."
::= { integraWifPortStcEntry 4 }
integraWrxDropped OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Dropped ingoing packets counter."
::= { integraWifPortStcEntry 5 }
integraWtxDetected OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Detected outgoing packets counter."
::= { integraWifPortStcEntry 6 }
integraWtxDropped OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Dropped outgoing packets counter."
::= { integraWifPortStcEntry 7 }
integraWrxBytes OBJECT-TYPE
SYNTAX Counter64
UNITS "B"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ingoing bytes counter."
::= { integraWifPortStcEntry 8 }
integraWtxBytes OBJECT-TYPE
SYNTAX Counter64
UNITS "B"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Outgoing bytes counter."
::= { integraWifPortStcEntry 9 }
integraWrx64Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 10 }
integraWrx65to127Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 11 }
integraWrx128to255Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 12 }
integraWrx256to511Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 13 }
integraWrx512to1023Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 14 }
integraWrx1024toMaxFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 15 }
integraWrxUsizeFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 16 }
integraWrxOsizeFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 17 }
integraWtx64Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 18 }
integraWtx65to127Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 19 }
integraWtx128to255Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 20 }
integraWtx256to511Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 21 }
integraWtx512to1023Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 22 }
integraWtx1024toMaxFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 23 }
integraWtxUsizeFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 24 }
integraWtxOsizeFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 25 }
integraWrxGoodFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 26 }
integraWrxErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 27 }
integraWrxFifoErr OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 28 }
integraWrxCRCErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 29 }
integraWrxBcastFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 30 }
integraWrxMcastFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 31 }
integraWrxCntrlFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 32 }
integraWrxLenErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 33 }
integraWrxVlanFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 34 }
integraWrxPauseFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 35 }
integraWrxOpErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 36 }
integraWrxFrameErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 37 }
integraWtxGoodFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 38 }
integraWtxErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 39 }
integraWtxFifoErr OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 40 }
integraWtxBcastFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 41 }
integraWtxMcastFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 42 }
integraWtxUrunErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 43 }
integraWtxCntrlFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 44 }
integraWtxVlanFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 45 }
integraWtxPauseFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 46 }
integraWtxSingleCollisions OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 47 }
integraWtxMultiCollisions OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 48 }
integraWtxDeferred OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 49 }
integraWtxLateCollisions OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 50 }
integraWtxExcessCollisions OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 51 }
integraWtxExcessDeferral OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 52 }
integraWtxAlignErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 53 }
integraWtxCarrierErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 54 }
integraWtxCollisions OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 55 }
-- Configuration applying/saving objects
integraWexecuteConfig OBJECT-TYPE
SYNTAX INTEGER {
execute(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object can only be set to 1.
It initiates new running configuration
applying using values, that have been set before.
Setting it when no new changes are available
will do nothing and return an error.
GET will return 0 if there were no errors,
while executing configuration or will return
a bitmask, that shows which SET requests have failed.
Those failed requests will be shown bit wise
from LSB as follows:
BIT0 radioTxMuteDuration
BIT1 radioTxFrequency
BIT2 radioTxPower"
::= { integraW 6 }
integraWneedStore OBJECT-TYPE
SYNTAX INTEGER {
no(0)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object shows if there is unsaved,
but executed (running) configuration.
Unsaved changes will be lost after
device reboot. Unsaved entities are shown
bit wise, starting from LSB as follows:
BIT0 Aggregation
BIT1 Event log
BIT2 Modem
BIT3 Network
BIT4 Performance
BIT5 Radio
BIT6 SNMP
BIT7 Synchronous Ethernet
BIT8 System"
::= { integraW 7 }
integraWstoreConfig OBJECT-TYPE
SYNTAX INTEGER {
store(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object can only be set to 1.
It initiates saving of running configuration.
It will only work if there are unsaved,
but executed (running) changes (configuration).
Setting it when no new running configuration
is available will do nothing and return an error."
::= { integraW 8 }
-- IP settings
integraWnetCfg OBJECT IDENTIFIER ::= { integraW 9 }
integraWnetCfgIPaddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Local IP address"
::= { integraWnetCfg 1 }
integraWnetCfgIPmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Local IP mask"
::= { integraWnetCfg 2 }
integraWnetCfgIPgateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "IP gateway
Send '0' or '255.255.255.255' to clear."
::= { integraWnetCfg 3 }
integraWnetCfgRemoteIPaddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Remote IP address"
::= { integraWnetCfg 4 }
-- Conformance
integraWConformance OBJECT IDENTIFIER ::= { integraW 10 }
integraWCompliances OBJECT IDENTIFIER ::= { integraWConformance 1 }
integraWCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "The compliance statement for SNMP engine which
implements the SAF Tehnika Integra-W device."
MODULE -- this module
MANDATORY-GROUPS {
integraWMiscGroup,
integraWRadioGroup,
integraWModemGroup,
integraWSystemGroup,
integraWEthernetGeneralGroup,
integraWEthernetMiiPortGroup }
::= { integraWCompliances 1 }
integraWGroups OBJECT IDENTIFIER ::= { integraWConformance 2 }
integraWMiscGroup OBJECT-GROUP
OBJECTS {
integraWtimestamp
}
STATUS current
DESCRIPTION "misc data"
::= { integraWGroups 1 }
integraWRadioGroup OBJECT-GROUP
OBJECTS {
integraWradioTxPower,
integraWradioTxFrequency,
integraWradioRxLevel,
integraWradioSide,
integraWradioTxMute,
integraWradioDuplexShift,
integraWradioRxFrequency,
integraWradioTemperature,
integraWradioTxMuteDuration,
integraWradioRangeEntryIndex,
integraWradioRangeDescr,
integraWradioRangeTxPower,
integraWradioRangeTxFrequency,
integraWradioPLL
}
STATUS current
DESCRIPTION "Radio group."
::= { integraWGroups 2 }
integraWModemGroup OBJECT-GROUP
OBJECTS {
integraWmodemAcquireStatus,
integraWmodemMse,
integraWmodemFecLoad,
integraWmodemSyncLoss,
integraWmodemBandwidth,
integraWmodemModulation,
integraWmodemRxModulation,
integraWmodemTxModulation,
integraWmodemRxCapacity,
integraWmodemTxCapacity,
integraWmodemAcmEngine,
integraWmodemSignalQuality
}
STATUS current
DESCRIPTION "Modem group."
::= { integraWGroups 3 }
integraWSystemGroup OBJECT-GROUP
OBJECTS {
integraWsysCPUtemperature,
integraWsysLicenseExpire,
integraWsysLicenseGenStatus,
integraWsysPSUvoltage,
integraWsysPSUcurrent,
integraWsysPSUpower,
integraWsysBoardTemperature,
integraWsysFreeMemory,
integraWsysCPUidle,
integraWexecuteConfig,
integraWneedStore,
integraWstoreConfig
}
STATUS current
DESCRIPTION "System group."
::= { integraWGroups 4 }
integraWEthernetGeneralGroup OBJECT-GROUP
OBJECTS {
integraWifPortStatIndex,
integraWifPortStatDescr,
integraWifPortType,
integraWifPortMtu,
integraWifPortSpeed,
integraWifPortPhysAddress,
integraWifPortAdminStatus,
integraWifPortOperStatus,
integraWifPortLastChange,
integraWifPortAutoneg,
integraWifPortDuplex,
integraWifPortSyncEthActive,
integraWifPortSyncEthPrio,
integraWifPortFlowControl,
integraWifPortStcIndex,
integraWifPortStcDescr,
integraWifTimePassed,
integraWnetCfgIPaddress,
integraWnetCfgIPmask,
integraWnetCfgIPgateway,
integraWnetCfgRemoteIPaddress
}
STATUS current
DESCRIPTION "A collection to objects, providing info applicable to
all network interfaces."
::= { integraWGroups 5 }
integraWEthernetMiiPortGroup OBJECT-GROUP
OBJECTS {
integraWrxDetected,
integraWrxDropped,
integraWtxDetected,
integraWtxDropped,
integraWrxBytes,
integraWtxBytes,
integraWrx64Frames,
integraWrx65to127Frames,
integraWrx128to255Frames,
integraWrx256to511Frames,
integraWrx512to1023Frames,
integraWrx1024toMaxFrames,
integraWrxUsizeFrames,
integraWrxOsizeFrames,
integraWtx64Frames,
integraWtx65to127Frames,
integraWtx128to255Frames,
integraWtx256to511Frames,
integraWtx512to1023Frames,
integraWtx1024toMaxFrames,
integraWtxUsizeFrames,
integraWtxOsizeFrames,
integraWrxGoodFrames,
integraWrxErrors,
integraWrxFifoErr,
integraWrxCRCErrors,
integraWrxBcastFrames,
integraWrxMcastFrames,
integraWrxCntrlFrames,
integraWrxLenErrors,
integraWrxVlanFrames,
integraWrxPauseFrames,
integraWrxOpErrors,
integraWrxFrameErrors,
integraWtxGoodFrames,
integraWtxErrors,
integraWtxFifoErr,
integraWtxBcastFrames,
integraWtxMcastFrames,
integraWtxUrunErrors,
integraWtxCntrlFrames,
integraWtxVlanFrames,
integraWtxPauseFrames,
integraWtxSingleCollisions,
integraWtxMultiCollisions,
integraWtxDeferred,
integraWtxLateCollisions,
integraWtxExcessCollisions,
integraWtxExcessDeferral,
integraWtxAlignErrors,
integraWtxCarrierErrors,
integraWtxCollisions
}
STATUS current
DESCRIPTION "A collection of objects, providing info applicable
only to MII group interfaces."
::= { integraWGroups 6 }
END
|