summaryrefslogtreecommitdiff
path: root/MIBS/riello/RIELLOMTS-MIB
blob: eca8691e8725366cd9f538523040c7a628022945 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
-- RPS S.p.A enterprise MIB definition

-- Copyright (c) RPS S.p.A.
-- Version: 1.0.1 by Michele Marcon
-- Date: 07.06.2017

-- Title: RIELLOMTS-MIB

-- MDU-MIB { iso org(3) dod(6) internet(1) private(4)
-- enterprises(1) riello(5491) }

-- ************************************************************************
-- ************************************************************************

RIELLOMTS-MIB DEFINITIONS ::= BEGIN

IMPORTS
     DisplayString
         FROM RFC1213-MIB
     OBJECT-TYPE
         FROM RFC-1212
     TRAP-TYPE
         FROM RFC-1215
     rielloMIB
             FROM RIELLO-MIB;


mtsMIB              OBJECT IDENTIFIER ::= { rielloMIB 12 }
                                    
mtsIdent              OBJECT IDENTIFIER ::= { mtsMIB 1 }

mtsIdentManufacturer OBJECT-TYPE
    SYNTAX     DisplayString
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The name of the mts manufacturer."
    ::= { mtsIdent 1 }

mtsIdentModel OBJECT-TYPE
    SYNTAX     DisplayString 
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The mts Model designation."
    ::= { mtsIdent 2 }

mtsIdentSoftwareVersion OBJECT-TYPE
    SYNTAX     DisplayString 
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The mts Software version."
    ::= { mtsIdent 3 }

mtsIdentIOConfiguration OBJECT-TYPE
    SYNTAX     INTEGER 
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The mts input/output configuration (1 for Mono/mono, 4 for Tri/tri)."
    ::= { mtsIdent 4 }

mtsIdentType OBJECT-TYPE
    SYNTAX     INTEGER 
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The mts type (5 for ATS, 6 for STS)."
    ::= { mtsIdent 5 }

mtsIdentInputSockets OBJECT-TYPE
    SYNTAX     INTEGER 
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The number of mts input sockets."
    ::= { mtsIdent 6 }

mtsIdentOutputSockets OBJECT-TYPE
    SYNTAX     INTEGER 
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The number of mts output sockets."
    ::= { mtsIdent 7 }

mtsIdentNominalCurrent OBJECT-TYPE
    SYNTAX     INTEGER 
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The mts nominal current (A)."
    ::= { mtsIdent 8 }

mtsIdentNominalVoltage OBJECT-TYPE
    SYNTAX     INTEGER 
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The mts nominal voltage (V)."
    ::= { mtsIdent 9 }

mtsIdentNominalFrequency OBJECT-TYPE
    SYNTAX     INTEGER 
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The mts nominal frequency (0.1 Hz)."
    ::= { mtsIdent 10 }

mtsStatus             OBJECT IDENTIFIER ::= { mtsMIB 2 }

mtsS1Frequency OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The frequency of source 1 (0.1 Hz)."
    ::= { mtsStatus 1 }

mtsS1VoltageL1 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The voltage of source 1, line 1 (V)."
    ::= { mtsStatus 2 }

mtsS1VoltageL2 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The voltage of source 1, line 2 (V)."
    ::= { mtsStatus 3 }

mtsS1VoltageL3 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The voltage of source 1, line 3 (V)."
    ::= { mtsStatus 4 }

mtsS2Frequency OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The frequency of source 2 (0.1 Hz)."
    ::= { mtsStatus 5 }

mtsS2VoltageL1 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The voltage of source 2, line 1 (V)."
    ::= { mtsStatus 6 }

mtsS2VoltageL2 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The voltage of source 2, line 2 (V)."
    ::= { mtsStatus 7 }

mtsS2VoltageL3 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The voltage of source 2, line 3 (V)."
    ::= { mtsStatus 8 }

mtsPhaseDifference OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "Phase difference between sources (degrees)."
    ::= { mtsStatus 9 }

mtsLoadL1 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The output load of line 1 (%)."
    ::= { mtsStatus 10 }

mtsLoadL2 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The output load of line 2 (%)."
    ::= { mtsStatus 11 }

mtsLoadL3 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The output load of line 3 (%)."
    ::= { mtsStatus 12 }

mtsOutputCurrentL1 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The output load current of line 1 (0.1 A)."
    ::= { mtsStatus 13 }

mtsOutputCurrentL2 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The output load current of line 2 (0.1 A)."
    ::= { mtsStatus 14 }

mtsOutputCurrentL3 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The output load current of line 3 (0.1 A)."
    ::= { mtsStatus 15 }

mtsTemperature OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "The temperature (degrees C)."
    ::= { mtsStatus 16 }

mtsSoundOff OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= sound on, 0= sound off."
    ::= { mtsStatus 17 }

mtsTestInProgress OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= test in progress, 0= test not in progress."
    ::= { mtsStatus 18 }

mtsAuxPower2fail OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= fail, 0= not fail."
    ::= { mtsStatus 19 }

mtsAuxPower1fail OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= fail, 0= not fail."
    ::= { mtsStatus 20 }

mtsSynchrobad OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= bad, 0= not bad."
    ::= { mtsStatus 21 }

mtsPreferredSource OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= S2, 0= S1."
    ::= { mtsStatus 22 }

mtsTransferhinibit OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= hinibit, 0= not hinibit."
    ::= { mtsStatus 23 }

mtsNonSynchInibit OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 24 }

mtsSourceS2bad OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= bad, 0= not bad."
    ::= { mtsStatus 25 }

mtsSourceS1bad OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= bad, 0= not bad."
    ::= { mtsStatus 26 }

mtsOnSourceS2 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 27 }

mtsOnSourceS1 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 28 }

mtsLocked OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= locked, 0= not locked."
    ::= { mtsStatus 29 }

mtsOutputSwitchOff OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 30 }

mtsS2Blackout OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= blackout, 0= no blackout."
    ::= { mtsStatus 31 }

mtsS2PhaseseqNotok OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 32 }

mtsS2VoltOutoftolerance OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 33 }

mtsS1SCRAlternateLoss OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 34 }

mtsS1InputSWOff OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 35 }

mtsS1Frequencybad OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= bad, 0= not bad."
    ::= { mtsStatus 36 }

mtsS1Balancebad OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 37 }

mtsS1Blackout OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 38 }

mtsS1PhaseseqNotok OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 39 }

mtsS1VoltOutoftolerance OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 40 }

mtsUserlogin OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 41 }

mtsAlarmTemperature OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 42 }

mtsAlarmOverload OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 43 }

mtsGeneralFailure OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 44 }

mtsS2InputMCCBtrip OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 45 }

mtsS1InputMCCBtrip OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 46 }

mtsServicelogin OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 47 }

mtsOutputSCRalternanceloss OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 48 }

mtsManBypassS2 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 49 }

mtsManBypassS1 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 50 }

mtsManTransferS2 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 51 }

mtsManTransferS1 OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 52 }

mtsS2SCRalternanceloss OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 53 }

mtsS2InputSWoff OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 54 }

mtsS2Frequencybad OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 55 }

mtsS2Balancebad OBJECT-TYPE
    SYNTAX     INTEGER
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
            "1= yes, 0= no."
    ::= { mtsStatus 56 }

       
mtsTraps OBJECT IDENTIFIER ::= { mtsMIB 4 }


mtsNormal TRAP-TYPE
       ENTERPRISE  mtsTraps
       DESCRIPTION "This trap is sent when STS is on normal status"
       ::= 1

mtsAnomaly TRAP-TYPE
       ENTERPRISE  mtsTraps
       DESCRIPTION "This trap is sent when STS is has some anomaly and is resent every minute"
       ::= 2
           
mtsFault TRAP-TYPE
       ENTERPRISE  mtsTraps
       DESCRIPTION "This trap is sent when STS is has some fault and is resent every minute"
       ::= 3

mtsLock TRAP-TYPE
       ENTERPRISE  mtsTraps
       DESCRIPTION "This trap is sent when STS is locked and is resent every minute"
       ::= 4

mtsManualBypassEnabled TRAP-TYPE
       ENTERPRISE  mtsTraps
       DESCRIPTION "This trap is sent when STS is on manual bypass and is resent every minute"
       ::= 5
           
END