1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
|
--MibName=rosMgmtAlarm
-- *****************************************************************
-- ROSMGMT-ALARM-MGMT-MIB.mib: ROSMGMT ALARM MIB
--
-- April 2011, yangguodong
--
-- Copyright (c) 1996-2011 by Raisecom Technology Co., Ltd.
-- All rights reserved.
--
-- *****************************************************************
--
ROSMGMT-ALARM-MGMT-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,OBJECT-TYPE,
Unsigned32,Integer32
FROM SNMPv2-SMI -- [RFC2578]
TEXTUAL-CONVENTION,TruthValue
FROM SNMPv2-TC -- [RFC2579]
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB -- [RFC3411]
ifIndex FROM IF-MIB
rosMgmt
FROM RAISECOM-BASE-MIB;
rosMgmtAlarmMgmt MODULE-IDENTITY
LAST-UPDATED "202006180000Z" -- 18 June 2020 00:00:00 GMT
ORGANIZATION "Raisecom Technology Co., Ltd."
CONTACT-INFO
"Raisecom Science & Technology Co., ltd.
E-mail: support@rosMgmt.com ."
DESCRIPTION
"This MIB module contains managed object definitions for
MPLS. "
REVISION "202006180000Z" -- 18 June 2020 00:00:00 GMT
DESCRIPTION
"Add alarm reversal mode to automatically flip state."
REVISION "201103120000Z" -- 12 March 2011 00:00:00 GMT
DESCRIPTION
"ROSMGMT ALARM MIB initial version."
::= { rosMgmt 34 }
--rosMgmtAlarmMgmt 0 notification
rosMgmtAlarmMgmtObejcts OBJECT IDENTIFIER ::= { rosMgmtAlarmMgmt 1 }
--rosMgmtAlarmMgmt 2 conformance group
-- User-defined types
AlarmStorageMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Describes how to store alarm active table when the alarm
table was full.When the storage mode is stop,the new raised
alarm will be discarded.It will not insert to alarm active table.
If the storage mode is loop,the oldest row in alarm active table
will be deleted and the the newly raiseco alarm will be inserted
to the alarm active table."
SYNTAX INTEGER {
stop(1), -- eh?
loop(2) -- e.g., in RAM
}
AlarmInverseMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Describes the mode of alarm inverse "
SYNTAX INTEGER {
none(1), -- inverse mode is non
auto(2), -- inverse mode is auto
manual(3), -- inverse mode is manual
autofinish(4) -- inverse mode is auto finish
}
--end user defined type
--start of alarm config
rosMgmtAlarmMgmtScalarGroup OBJECT IDENTIFIER ::= { rosMgmtAlarmMgmtObejcts 1 }
rosMgmtAlarmMgmtRaiseDelay OBJECT-TYPE
SYNTAX Integer32 (0..600)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The approximate period from the time a alarm was
raised to a time this alarm was reported."
DEFVAL { 0 }
::= { rosMgmtAlarmMgmtScalarGroup 1}
rosMgmtAlarmMgmtClearDelay OBJECT-TYPE
SYNTAX Integer32 (0..600)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The approximate period from the time a alarm was
cleared to a time this alarm report."
DEFVAL { 0 }
::= { rosMgmtAlarmMgmtScalarGroup 2 }
rosMgmtAlarmMgmtActiveStoreMode OBJECT-TYPE
SYNTAX AlarmStorageMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The storage mode of the alarm active table"
::= { rosMgmtAlarmMgmtScalarGroup 3 }
rosMgmtAlarmMgmtInhibitEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or Disable Alarm Inhibit"
DEFVAL { true }
::= { rosMgmtAlarmMgmtScalarGroup 4 }
rosMgmtAlarmMgmtSyslogEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or Disable write syslog when an alarm raise"
DEFVAL { true }
::= { rosMgmtAlarmMgmtScalarGroup 5 }
rosMgmtAlarmMgmtActiveClear OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"clear active alarm according to the active table third index"
::= { rosMgmtAlarmMgmtScalarGroup 6 }
rosMgmtAlarmMgmtConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RosMgmtAlarmMgmtConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table specifies the information of alarm configuration."
::= { rosMgmtAlarmMgmtObejcts 2 }
rosMgmtAlarmMgmtConfigEntry OBJECT-TYPE
SYNTAX RosMgmtAlarmMgmtConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in this table represents the configuration of specified alarm."
INDEX { rosMgmtAlarmMgmtId,ifIndex }
::= { rosMgmtAlarmMgmtConfigTable 1 }
RosMgmtAlarmMgmtConfigEntry ::= SEQUENCE {
rosMgmtAlarmMgmtId Unsigned32,
rosMgmtAlarmMgmtClear TruthValue,
rosMgmtAlarmMgmtReportEnable TruthValue,
rosMgmtAlarmMgmtMonitorEnable TruthValue,
rosMgmtAlarmMgmtInverseMode AlarmInverseMode,
rosMgmtAlarmMgmtModuleName SnmpAdminString,
rosMgmtAlarmMgmtGroupName SnmpAdminString
}
rosMgmtAlarmMgmtId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"First index of alarm config table which is equal to alarm group Id"
::= { rosMgmtAlarmMgmtConfigEntry 1 }
rosMgmtAlarmMgmtClear OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The swith of alarm clear,when open the swith the related
active alarm entry will be deleted from alarm active table"
DEFVAL { false }
::= { rosMgmtAlarmMgmtConfigEntry 2 }
rosMgmtAlarmMgmtReportEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable Alarm Report"
DEFVAL { true }
::= { rosMgmtAlarmMgmtConfigEntry 3 }
rosMgmtAlarmMgmtMonitorEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable alarm monitor"
DEFVAL { true }
::= { rosMgmtAlarmMgmtConfigEntry 4 }
rosMgmtAlarmMgmtInverseMode OBJECT-TYPE
SYNTAX AlarmInverseMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mode of alarm inverse"
DEFVAL { none }
::= { rosMgmtAlarmMgmtConfigEntry 5 }
rosMgmtAlarmMgmtModuleName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The module name which this alarm belongs to."
::= { rosMgmtAlarmMgmtConfigEntry 6 }
rosMgmtAlarmMgmtGroupName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of alarm group."
::= { rosMgmtAlarmMgmtConfigEntry 7 }
rosMgmtAlarmMgmtCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF RosMgmtAlarmMgmtCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table specifies the information of alarm configuration."
::= { rosMgmtAlarmMgmtObejcts 3 }
rosMgmtAlarmMgmtCfgEntry OBJECT-TYPE
SYNTAX RosMgmtAlarmMgmtCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in this table represents the configuration of specified alarm."
INDEX { rosMgmtAlarmMgmtCfgAlarmType,rosMgmtAlarmMgmtCfgAlarmResType,rosMgmtAlarmMgmtCfgAlarmRes}
::= { rosMgmtAlarmMgmtCfgTable 1 }
RosMgmtAlarmMgmtCfgEntry ::= SEQUENCE {
rosMgmtAlarmMgmtCfgAlarmType Unsigned32,
rosMgmtAlarmMgmtCfgAlarmResType INTEGER,
rosMgmtAlarmMgmtCfgAlarmRes Unsigned32,
rosMgmtAlarmMgmtCfgClear TruthValue,
rosMgmtAlarmMgmtCfgMonitorEnable TruthValue,
rosMgmtAlarmMgmtCfgReportEnable TruthValue,
rosMgmtAlarmMgmtCfgInverseMode AlarmInverseMode
}
rosMgmtAlarmMgmtCfgAlarmType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Third index of alarm Mgmt config table.The type of Alarm."
::= { rosMgmtAlarmMgmtCfgEntry 1 }
rosMgmtAlarmMgmtCfgAlarmResType OBJECT-TYPE
SYNTAX INTEGER {
slotindex(1), --告警源:板卡
pwindex(2), --告警源:PW
lspindex(3), --告警源:LSP
loifindex(4), --告警源:LOOPBACK口
agifindex(5), --告警源:AG口
apifindex(6), --告警源:AP口
obifindex(7), --告警源:OUTBAND口
tdmifindex(8), --告警源:TDM口
tunnelifindex(9), --告警源:TRUNK口
vlanifindex(10), --告警源:VLAN口
subifindex(11), --告警源:SUBIF口
portindex(12), --告警源:端口
apagsubifindex(13), --告警源:AP,AG,子接口
powerindex(14), --告警源:电源
fanindex(15), --告警源:风扇
boardindex(16), --告警源:板卡,电源,风扇
cfmindex(17),
erpsindex(18),
apsindex(19),
bfdindex(20),
ldpindex(21),
lsaindex(22),
ifindex(23),
cpuindex(24),
tdmsubifindex(25),
tdmtdmsubifindex(26),
stmifindex(27),
stmsubifindex(28),
stmsubtdmtdmsubindex(29),
stmvcindex(30),
eponifindex(31),
eonuifindex(32),
eonusubifindex(33),
apeponifindex(34),
apagvlansubifindex(35)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"First index of alarm Mgmt config table.The type of Alarm Resoure."
::= { rosMgmtAlarmMgmtCfgEntry 2 }
rosMgmtAlarmMgmtCfgAlarmRes OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Second index of alarm Mgmt config table.The value of Alarm Resoure."
::= { rosMgmtAlarmMgmtCfgEntry 3 }
rosMgmtAlarmMgmtCfgClear OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The swith of alarm clear,when open the swith, the related active alarm entry will be deleted from alarm active table."
DEFVAL { false }
::= { rosMgmtAlarmMgmtCfgEntry 4 }
rosMgmtAlarmMgmtCfgMonitorEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable alarm Monitor."
DEFVAL { true }
::= { rosMgmtAlarmMgmtCfgEntry 5 }
rosMgmtAlarmMgmtCfgReportEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable alarm Report."
DEFVAL { true }
::= { rosMgmtAlarmMgmtCfgEntry 6 }
rosMgmtAlarmMgmtCfgInverseMode OBJECT-TYPE
SYNTAX AlarmInverseMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Alarm Inverse Mode."
DEFVAL { none }
::= { rosMgmtAlarmMgmtCfgEntry 7 }
--end of alarm config
rosMgmtAlarmMgmtMonitorLevel OBJECT-TYPE
SYNTAX INTEGER {
clear(1),
indeterminate(2),
critical(3),
major(4),
minor(5),
warning(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The level of Alarm Monitor."
DEFVAL { minor }
::= { rosMgmtAlarmMgmtScalarGroup 7}
rosMgmtAlarmMgmtClearLevel OBJECT-TYPE
SYNTAX INTEGER {
clear(1),
indeterminate(2),
critical(3),
major(4),
minor(5),
warning(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The level of Alarm Monitor."
::= { rosMgmtAlarmMgmtScalarGroup 8}
rosMgmtAlarmMgmtMonitor OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or Disable Alarm Monitor."
DEFVAL { true }
::= { rosMgmtAlarmMgmtScalarGroup 9 }
rosMgmtAlarmMgmtCorrelationInhibit OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or Disable Alarm CorrelationInhibit."
DEFVAL { true }
::= { rosMgmtAlarmMgmtScalarGroup 10 }
rosMgmtAlarmMgmtReport OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or Disable Alarm Report."
DEFVAL { true }
::= { rosMgmtAlarmMgmtScalarGroup 11 }
-- rosMgmtAlarmMgmtCfgOutPutTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF RaisecomAlarmMgmtCfgOutPutEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table specifies the information of alarm configuration."
-- ::= { rosMgmtAlarmMgmtObejcts 14 }
--
-- rosMgmtAlarmMgmtCfgOutPutEntry OBJECT-TYPE
-- SYNTAX RaisecomAlarmMgmtCfgOutPutEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "A row in this table represents the configuration of specified alarm."
-- INDEX { rosMgmtAlarmMgmtAlarmOutputGroupIndex, rosMgmtAlarmMgmtAlarmOutputType}
-- ::= { rosMgmtAlarmMgmtCfgOutPutTable 1 }
--
-- RaisecomAlarmMgmtCfgOutPutEntry ::= SEQUENCE {
-- rosMgmtAlarmMgmtAlarmOutputGroupIndex INTEGER,
-- rosMgmtAlarmMgmtAlarmOutputType Unsigned32,
-- rosMgmtAlarmMgmtAlarmOutputRowStatus TruthValue
-- }
--
-- rosMgmtAlarmMgmtAlarmOutputGroupIndex OBJECT-TYPE
-- SYNTAX INTEGER (1..2)
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The index of alarm Mgmt OutputGroup table."
-- ::= { rosMgmtAlarmMgmtCfgOutPutEntry 1}
--
-- rosMgmtAlarmMgmtAlarmOutputType OBJECT-TYPE
-- SYNTAX Unsigned32
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "Third index of alarm Mgmt config table.The type of Alarm."
-- ::= { rosMgmtAlarmMgmtCfgOutPutEntry 2 }
--
-- rosMgmtAlarmMgmtAlarmOutputRowStatus OBJECT-TYPE
-- SYNTAX TruthValue
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Enable or disable Alarm Output"
-- DEFVAL { true }
-- ::= { rosMgmtAlarmMgmtCfgOutPutEntry 3}
--
--
-- rosMgmtAlarmMgmtCfgOutPutGroupTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF RaisecomAlarmMgmtCfgOutPutGroupEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table specifies the information of alarm configuration."
-- ::= { rosMgmtAlarmMgmtObejcts 15 }
--
-- rosMgmtAlarmMgmtCfgOutPutGroupEntry OBJECT-TYPE
-- SYNTAX RaisecomAlarmMgmtCfgOutPutGroupEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "A row in this table represents the configuration of specified alarm."
-- INDEX { rosMgmtAlarmMgmtAlarmOutputgrpIndex}
-- ::= { rosMgmtAlarmMgmtCfgOutPutGroupTable 1 }
--
-- RaisecomAlarmMgmtCfgOutPutGroupEntry ::= SEQUENCE {
-- rosMgmtAlarmMgmtAlarmOutputgrpIndex INTEGER,
-- rosMgmtAlarmMgmtAlarmOutputEnable EnableVar
-- }
--
-- rosMgmtAlarmMgmtAlarmOutputgrpIndex OBJECT-TYPE
-- SYNTAX INTEGER (1..2)
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The index of alarm Mgmt OutputGroup table."
-- ::= { rosMgmtAlarmMgmtCfgOutPutGroupEntry 1}
--
-- rosMgmtAlarmMgmtAlarmOutputEnable OBJECT-TYPE
-- SYNTAX EnableVar
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Third index of alarm Mgmt config table.The type of Alarm."
-- ::= { rosMgmtAlarmMgmtCfgOutPutGroupEntry 2 }
END
|