1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
|
-- =======================================================================
-- Version info
--
-- Version 0.1 Created 2011.03.09 by wuliang
-- Copyright(c) 2003-2007 by RAISECOM TECH, Ltd.
-- =======================================================================
-- ===========================================================================
-- 111
-- RAISECOM base management objects
--
RAISECOM-PON-DEVICE-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE ,
Integer32,
IpAddress,
Unsigned32
FROM SNMPv2-SMI
DisplayString,
TimeStamp,
RowStatus,
TruthValue,
MacAddress
FROM SNMPv2-TC
EnableVar
FROM SWITCH-TC
SlotIndex,
PONDeviceType,
PONDeviceCardType
FROM RAISECOM-PONSERIES-TC
raisecomAgent
FROM RAISECOM-BASE-MIB;
raisecomdeviceMgt MODULE-IDENTITY
LAST-UPDATED "201103091000Z"
ORGANIZATION "RAISECOM TECH, Ltd."
CONTACT-INFO "www.raisecom.com"
DESCRIPTION
"The MIB module defining objects for device management"
::= { raisecomAgent 27}
--groups
raisecomNEEquip OBJECT IDENTIFIER ::= {raisecomdeviceMgt 1}
raisecomShelf OBJECT IDENTIFIER ::= {raisecomdeviceMgt 2}
raisecomSlot OBJECT IDENTIFIER ::= {raisecomdeviceMgt 3}
raisecomPower OBJECT IDENTIFIER ::= {raisecomdeviceMgt 4}
raisecomFan OBJECT IDENTIFIER ::= {raisecomdeviceMgt 5}
-- raisecomOutbandMgtPort OBJECT IDENTIFIER ::= {raisecomdeviceMgt 6}
-- raisecomConsolePort OBJECT IDENTIFIER ::= {raisecomdeviceMgt 7}
raisecomDeviceAlarm OBJECT IDENTIFIER ::= {raisecomdeviceMgt 8}
raisecomAlarmInput OBJECT IDENTIFIER ::= {raisecomdeviceMgt 10}
raisecomCardTemplate OBJECT IDENTIFIER ::= {raisecomdeviceMgt 11}
raisecomCardPower OBJECT IDENTIFIER ::= {raisecomdeviceMgt 12}
-- raisecomNEEquip
raisecomNEType OBJECT-TYPE
SYNTAX PONDeviceType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Network element type."
::= { raisecomNEEquip 1 }
raisecomNEAssetID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Asset ID of this network element for the carrier."
::= { raisecomNEEquip 2 }
raisecomNEMfrVendor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Vendor name for this network element."
::= { raisecomNEEquip 3 }
raisecomNETmptAlarmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Temperature threshold to issure the temperature alarm. The applicability depends on the device type."
DEFVAL { 70 }
::= { raisecomNEEquip 4 }
--raisecomShelf
raisecomShelfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaisecomShelfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Shelf management table."
::= { raisecomShelf 1 }
raisecomShelfEntry OBJECT-TYPE
SYNTAX RaisecomShelfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Shelf management table entry."
INDEX { raisecomShelfId }
::= { raisecomShelfTable 1 }
RaisecomShelfEntry ::= SEQUENCE {
raisecomShelfId Integer32,
raisecomShelfDescr OCTET STRING (SIZE (0..64)),
raisecomShelfSerialNum OCTET STRING (SIZE (0..64)),
raisecomShelfHwVersion OCTET STRING (SIZE (0..64)),
raisecomShelfLevel INTEGER,
raisecomShelfType OCTET STRING (SIZE (0..64)),
raisecomShelfGenType INTEGER,
raisecomShelfMfrVendor OCTET STRING (SIZE (0..64)),
raisecomShelfAssetID OCTET STRING (SIZE (0..64)),
raisecomShelfTemperature INTEGER,
raisecomShelfSlotNum Integer32,
raisecomShelfNMSSlotNum INTEGER,
raisecomShelfPrimaryNMSSlotId Integer32,
raisecomShelfSecondaryNMSSlotId Integer32,
raisecomShelfMac MacAddress
}
raisecomShelfId OBJECT-TYPE
SYNTAX Integer32(0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Shelf id."
::= { raisecomShelfEntry 1 }
raisecomShelfDescr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Shelf description."
::= { raisecomShelfEntry 2 }
raisecomShelfSerialNum OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Shelf device serial number."
::= { raisecomShelfEntry 3 }
raisecomShelfHwVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shelf hardware version.
For pizza-box type of device, it indicates version of the device, not of the card.
For other type of device, it indicates version of the shelf, mainly of the backplane."
::= { raisecomShelfEntry 4 }
raisecomShelfLevel OBJECT-TYPE
SYNTAX INTEGER {
masterShelf(1),
extendShelf1(2),
extendShelf2(3),
extendShelf3(4),
extendShelf4(5),
extendShelf5(6),
extendShelf6(7),
extendShelf7(8),
extendShelf8(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Shelf level."
::= { raisecomShelfEntry 5 }
raisecomShelfType OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Shelf type."
::= { raisecomShelfEntry 6 }
raisecomShelfGenType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
chassis(3),
backplane(4),
container(5),
powerSupply(6),
fan(7),
sensor(8),
module(9),
port(10),
stack(11)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Shelf Species."
::= { raisecomShelfEntry 7 }
raisecomShelfMfrVendor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Vendor name for this shelf."
::= { raisecomShelfEntry 8 }
raisecomShelfAssetID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Asset ID of this shelf."
::= { raisecomShelfEntry 9 }
raisecomShelfTemperature OBJECT-TYPE
SYNTAX INTEGER (-100..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Temperature of this shelf."
::= { raisecomShelfEntry 10 }
raisecomShelfSlotNum OBJECT-TYPE
SYNTAX Integer32(0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of slots for installing cards in this shelf."
::= { raisecomShelfEntry 11 }
raisecomShelfNMSSlotNum OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of slots for management and control cards in this shelf."
::= { raisecomShelfEntry 12 }
raisecomShelfPrimaryNMSSlotId OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Slot for the primary management and control card."
::= { raisecomShelfEntry 13 }
raisecomShelfSecondaryNMSSlotId OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Slot for the secondary management and control card.
Valid only when raisecomShelfNMSSlotNum equals to 2."
::= { raisecomShelfEntry 14 }
raisecomShelfMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MAC address of this shelf."
::= { raisecomShelfEntry 15 }
-- raisecomCardTemplate
raisecomCardTemplateTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaisecomCardTemplateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Card Template table."
::= { raisecomCardTemplate 1 }
raisecomCardTemplateEntry OBJECT-TYPE
SYNTAX RaisecomCardTemplateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Card template table entry."
INDEX { raisecomCardType }
::= { raisecomCardTemplateTable 1 }
RaisecomCardTemplateEntry ::=
SEQUENCE {
raisecomCardType PONDeviceCardType,
raisecomCardPanelPortNum Integer32(0..16),
raisecomCardPanelPortTypes OCTET STRING (SIZE(0..32)),
raisecomCardPermitedSlots INTEGER
}
raisecomCardType OBJECT-TYPE
SYNTAX PONDeviceCardType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The card type of this template."
::= { raisecomCardTemplateEntry 1 }
raisecomCardPanelPortNum OBJECT-TYPE
SYNTAX Integer32(0..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Plane port number of this card-type template."
::= { raisecomCardTemplateEntry 2 }
raisecomCardPanelPortTypes OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Plane port types of this type card template."
::= { raisecomCardTemplateEntry 3 }
raisecomCardPermitedSlots OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "All the slot id of this type card which can be installed."
::= { raisecomCardTemplateEntry 4 }
-- raisecomSlot
raisecomSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaisecomSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Card slot management table."
::= { raisecomSlot 1 }
raisecomSlotEntry OBJECT-TYPE
SYNTAX RaisecomSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Card slot management table entry."
INDEX { raisecomSlotId }
::= { raisecomSlotTable 1 }
RaisecomSlotEntry ::=
SEQUENCE {
raisecomSlotId SlotIndex,
raisecomSlotDescr OCTET STRING (SIZE(0..64)),
raisecomSlotExpectCardType PONDeviceCardType,
raisecomSlotExpectCardDescr OCTET STRING (SIZE(0..64)),
raisecomSlotActCardType PONDeviceCardType,
raisecomSlotActCardDescr OCTET STRING (SIZE(0..64)),
raisecomSlotActCardSerialNum OCTET STRING (SIZE(0..64)),
raisecomSlotActCardHwVersion OCTET STRING (SIZE(0..64)),
raisecomSlotActCardMfrVendor OCTET STRING (SIZE(0..64)),
raisecomSlotActCardAssetID OCTET STRING (SIZE(0..64)),
raisecomSlotActCardState INTEGER,
raisecomSlotReboot INTEGER,
raisecomSlotSupportCardTypes OCTET STRING (SIZE(0..128)),
raisecomSlotActCardSwVersion OCTET STRING (SIZE(0..64)),
raisecomSlotPowerState INTEGER
}
raisecomSlotId OBJECT-TYPE
SYNTAX SlotIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Slot id."
::= { raisecomSlotEntry 1 }
raisecomSlotDescr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Slot description."
::= { raisecomSlotEntry 2 }
raisecomSlotExpectCardType OBJECT-TYPE
SYNTAX PONDeviceCardType
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Expected card type."
::= { raisecomSlotEntry 3 }
raisecomSlotExpectCardDescr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Description of the expected card. Currently unused."
::= { raisecomSlotEntry 4 }
raisecomSlotActCardType OBJECT-TYPE
SYNTAX PONDeviceCardType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of the card actually installed."
::= { raisecomSlotEntry 5 }
raisecomSlotActCardDescr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Description of the card actually installed. The applicability depends on the card type."
::= { raisecomSlotEntry 6 }
raisecomSlotActCardSerialNum OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial number of the card actually installed."
::= { raisecomSlotEntry 7 }
raisecomSlotActCardHwVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Hardware version of the card actually installed."
::= { raisecomSlotEntry 8 }
raisecomSlotActCardMfrVendor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Vender name of the card actually installed."
::= { raisecomSlotEntry 9 }
raisecomSlotActCardAssetID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Asset id of the card actually installed."
::= { raisecomSlotEntry 10 }
raisecomSlotActCardState OBJECT-TYPE
SYNTAX INTEGER {
lost(1),
poweroffed(13),
offline(2),
type-identifying(11),
nonprovision(3),
typemismatched(4),
generalfault(5),
versionmismatched(6),
initialized(12),
configloading(7),
configfailed(8),
inservice(9),
standby(10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Working state of the card actually installed."
::= { raisecomSlotEntry 11 }
raisecomSlotReboot OBJECT-TYPE
SYNTAX INTEGER {
cold(1),
warm(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Reboot the card. Result of reading this attribute is undefined."
::= { raisecomSlotEntry 12 }
raisecomSlotSupportCardTypes OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The slots on which the card type can be installed"
::= { raisecomSlotEntry 13 }
raisecomSlotActCardSwVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "softerware version of the card actually installed."
::= { raisecomSlotEntry 14 }
raisecomSlotPowerState OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "set card power-save state on the slot."
::= { raisecomSlotEntry 15 }
-- raisecomPower
raisecomPowerDeviceTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaisecomPowerDeviceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Power device management table."
::= { raisecomPower 1 }
raisecomPowerDeviceEntry OBJECT-TYPE
SYNTAX RaisecomPowerDeviceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Power device management table entry."
INDEX { raisecomPowerDeviceIndex }
::= { raisecomPowerDeviceTable 1 }
RaisecomPowerDeviceEntry ::=
SEQUENCE {
raisecomPowerDeviceIndex SlotIndex,
raisecomPowerDeviceInputType INTEGER,
-- raisecomPowerExpectType INTEGER,
-- raisecomPowerActualType INTEGER,
-- raisecomPowerManageable INTEGER,
-- raisecomPowerSwVersion OCTET STRING (SIZE(0..16)),
-- raisecomPowerHwVersion OCTET STRING (SIZE(0..16)),
-- raisecomPowertemperature Integer32,
raisecomPowerInputvol Integer32,
raisecomPowerInputvolalarmState INTEGER,
raisecomPowerInputvolMinlowerVolThres Integer32,
raisecomPowerInputvolMinupperVolThres Integer32,
raisecomPowerInputvolMajlowerVolThres Integer32,
raisecomPowerInputvolMajupperVolThres Integer32,
raisecomPowerInputvolCrilowerVolThres Integer32,
raisecomPowerInputvolCriupperVolThres Integer32,
raisecomPowerTemperatureThres Integer32
-- raisecomPowerSerialNum OCTET STRING (SIZE(0..64))
}
raisecomPowerDeviceIndex OBJECT-TYPE
SYNTAX SlotIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Power device id."
::= { raisecomPowerDeviceEntry 1 }
raisecomPowerDeviceInputType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ac(2),
dc48(3),
dc24(4),
dc12(5),
null(6),
ac220(7),
ac110(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Input type of this power device. Null value means that this power device is plugged out."
::= { raisecomPowerDeviceEntry 2 }
-- raisecomPowerExpectType OBJECT-TYPE
-- SYNTAX INTEGER {
-- any(1),
-- subPwrmAc(2),
-- subPwrmDc(3)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION "Expected power type,the default type is any(1), not used in V2.0"
-- ::= { raisecomPowerDeviceEntry 3 }
-- raisecomPowerActualType OBJECT-TYPE
-- SYNTAX INTEGER {
-- unknown(0),
-- subPwrmAc(2),
-- subPwrmDc(3),
-- subPwriiAc(4),
-- null(5)
-- }
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION "the actual power type ,Null value means that this power device is plugged out."
-- ::= { raisecomPowerDeviceEntry 4 }
-- raisecomPowerManageable OBJECT-TYPE
-- SYNTAX INTEGER {
-- yes(1),
-- no(2)
-- }
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION "Whether it is manageable by the NMS of this type power, not used in V2.0."
-- ::= { raisecomPowerDeviceEntry 5 }
-- raisecomPowerSwVersion OBJECT-TYPE
-- SYNTAX OCTET STRING (SIZE(0..16))
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION "the software version of this type power."
-- ::= { raisecomPowerDeviceEntry 6 }
-- raisecomPowerHwVersion OBJECT-TYPE
-- SYNTAX OCTET STRING (SIZE(0..16))
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION "the hardware version of this type power."
-- ::= { raisecomPowerDeviceEntry 7 }
-- raisecomPowertemperature OBJECT-TYPE
-- SYNTAX Integer32(-100..150)
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION "The temperature of this power device,it is only meaningful for the manageable power,
-- this node doesnot used in V2.0."
-- ::= { raisecomPowerDeviceEntry 8 }
raisecomPowerInputvol OBJECT-TYPE
SYNTAX Integer32(-100..300)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The input voltage of this power device, it is only meaningful for the manageable power."
::= { raisecomPowerDeviceEntry 9 }
raisecomPowerInputvolalarmState OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
lowMin(2),
lowMaj(3),
lowCri(4),
uppMin(5),
uppMaj(6),
uppCri(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The input voltage alarm state of the power device, it is only meaningful for the manageable power."
::= { raisecomPowerDeviceEntry 10 }
raisecomPowerInputvolMinlowerVolThres OBJECT-TYPE
SYNTAX Integer32(0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The input voltage lower threshold of the Minor alarm , it is only meaningful for the manageable power."
::= { raisecomPowerDeviceEntry 11 }
raisecomPowerInputvolMajlowerVolThres OBJECT-TYPE
SYNTAX Integer32(0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The input voltage lower threshold of the Major alarm,
it is only meaningful for the manageable power ."
::= { raisecomPowerDeviceEntry 12 }
raisecomPowerInputvolCrilowerVolThres OBJECT-TYPE
SYNTAX Integer32(0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The input voltage lower threshold of the Critical alarm ,
it is only meaningful for the manageable power."
::= { raisecomPowerDeviceEntry 13 }
raisecomPowerInputvolMinupperVolThres OBJECT-TYPE
SYNTAX Integer32(0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The input voltage upper threshold of the Minor alarm ,
it is only meaningful for the manageable power."
::= { raisecomPowerDeviceEntry 14 }
raisecomPowerInputvolMajupperVolThres OBJECT-TYPE
SYNTAX Integer32(0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The input voltage upper threshold of the Major alarm ,
it is only meaningful for the manageable power."
::= { raisecomPowerDeviceEntry 15 }
raisecomPowerInputvolCriupperVolThres OBJECT-TYPE
SYNTAX Integer32(0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The input voltage upper threshold of the Critical alarm ,
it is only meaningful for the manageable power."
::= { raisecomPowerDeviceEntry 16 }
raisecomPowerTemperatureThres OBJECT-TYPE
SYNTAX Integer32(0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The temperature threshold of the power device ,
it is only meaningful for the manageable power, not used in V2.0."
DEFVAL {85}
::= { raisecomPowerDeviceEntry 17 }
-- raisecomPowerSerialNum OBJECT-TYPE
-- SYNTAX OCTET STRING (SIZE(0..64))
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION "the serial nums of this power device."
-- ::= { raisecomPowerDeviceEntry 18 }
-- raisecomPowerOutputTable
raisecomPowerOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaisecomPowerOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Power device output management table."
::= { raisecomPower 2 }
raisecomPowerOutputEntry OBJECT-TYPE
SYNTAX RaisecomPowerOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Power device output management table entry."
INDEX { raisecomPowerDeviceIndex, raisecomPowerOutputType }
::= { raisecomPowerOutputTable 1 }
RaisecomPowerOutputEntry ::=
SEQUENCE {
raisecomPowerOutputType INTEGER,
raisecomPowerStatus INTEGER,
raisecomPowerOutputvol Integer32,
raisecomPowerOutputvollowerThres Integer32,
raisecomPowerOutputvolupperThres Integer32
}
raisecomPowerOutputType OBJECT-TYPE
SYNTAX INTEGER {
rcPowerOther(1),
rcPower3v(2),
rcPower5v(3),
rcPower12v(4),
rcPower-48v(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Output type of the power device."
::= { raisecomPowerOutputEntry 1 }
raisecomPowerStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
abnormal(2),
null(3),
highAlarm(4),
lowAlarm(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Output status of this power output. Null value means that this output port does not exist."
::= { raisecomPowerOutputEntry 2 }
raisecomPowerOutputvol OBJECT-TYPE
SYNTAX Integer32(-1000..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Output voltage of the power,it is only meaningful for the manageable power,
for the 5v output voltage ,the unit is 0.01v; for the -48V output voltage, the unit is 0.1v"
::= { raisecomPowerOutputEntry 3 }
raisecomPowerOutputvollowerThres OBJECT-TYPE
SYNTAX Integer32(-500..500)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold of the low output voltage alarm,it is only meaningful for the manageable power,
for the 5v output voltage ,the unit is 0.01v; for the -48V output voltage, the unit is 0.1v"
::= { raisecomPowerOutputEntry 4 }
raisecomPowerOutputvolupperThres OBJECT-TYPE
SYNTAX Integer32(-600..600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold of the high output voltage alarm,it is only meaningful for the manageable power,
for the 5v output voltage ,the unit is 0.01v; for the -48V output voltage, the unit is 0.1v"
::= { raisecomPowerOutputEntry 5 }
-- other table define here
--raisecomSubFanTable
raisecomSubFanTable OBJECT-TYPE
SYNTAX SEQUENCE OF raisecomSubFanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Fan management table."
::= { raisecomFan 1 }
raisecomSubFanEntry OBJECT-TYPE
SYNTAX raisecomSubFanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Fan management table entry."
INDEX { raisecomFanSlotId, raisecomSubFanId }
::= { raisecomSubFanTable 1 }
raisecomSubFanEntry ::=
SEQUENCE {
raisecomFanSlotId SlotIndex,
raisecomSubFanId INTEGER,
raisecomSubFanStatus INTEGER,
raisecomSubFanSpeed INTEGER
}
raisecomFanSlotId OBJECT-TYPE
SYNTAX SlotIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Slot Index."
::= { raisecomSubFanEntry 1 }
raisecomSubFanId OBJECT-TYPE
SYNTAX SlotIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Sub Fan Index."
::= { raisecomSubFanEntry 2 }
raisecomSubFanStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
abnormal(2),
null(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Fan status. Null value means that this fan is plugged out."
::= { raisecomSubFanEntry 3 }
raisecomSubFanSpeed OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Fan current speed."
::= { raisecomSubFanEntry 4 }
raisecomFanMaxSpeed OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "the maximum fan speed."
DEFVAL {3300}
::= { raisecomFan 2 }
raisecomFanMinSpeed OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "the minimun fan speed."
DEFVAL {900}
::= { raisecomFan 3 }
raisecomFanSpeedMode OBJECT-TYPE
SYNTAX INTEGER
{
auto(1),
manual(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "the fan control mode ,auto means the fan speed is controled
by the temperature automatically,the other means controled manually."
DEFVAL {auto}
::= { raisecomFan 4 }
raisecomFanSpeedManual OBJECT-TYPE
SYNTAX INTEGER (0..40)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "manual control the fan speed by configurating the fan different gear."
DEFVAL {8}
::= { raisecomFan 5 }
raisecomFanSpeedGear OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "the fan speed gear."
::= { raisecomFan 6 }
--raisecomCardPower
raisecomCardPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaisecomCardPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Card power management table."
::= { raisecomCardPower 1 }
raisecomCardPowerEntry OBJECT-TYPE
SYNTAX RaisecomCardPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "card power management table entry."
INDEX { raisecomCardPowerSlotId, raisecomCardPowerType}
::= { raisecomCardPowerTable 1 }
RaisecomCardPowerEntry ::=
SEQUENCE {
raisecomCardPowerSlotId SlotIndex,
raisecomCardPowerType INTEGER,
raisecomCardPowerVolValue Integer32,
raisecomCardPowerVolHighThres Integer32,
raisecomCardPowerVolLowThres Integer32
}
raisecomCardPowerSlotId OBJECT-TYPE
SYNTAX SlotIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Slot Index."
::= { raisecomCardPowerEntry 1 }
raisecomCardPowerType OBJECT-TYPE
SYNTAX INTEGER
{
power075v(1),
power09v(2),
power1v(3),
power12v(4),
power15v(5),
power18v(6),
power25v(7),
power33v(8),
power48v(9),
power5v(10),
power52v(11),
power120v(12),
unknown(13),
null(14),
power125v(15),
power29v(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "card power types."
::= { raisecomCardPowerEntry 2 }
raisecomCardPowerVolValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "the current card voltage of the power type."
::= { raisecomCardPowerEntry 3 }
raisecomCardPowerVolHighThres OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "the high voltage threshold of the power."
::= { raisecomCardPowerEntry 4 }
raisecomCardPowerVolLowThres OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "the low voltage threshold of the power."
::= { raisecomCardPowerEntry 5 }
--raisecomAlarmInput
raisecomAlarmInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaisecomAlarmInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Alarm input management table."
::= { raisecomAlarmInput 1 }
raisecomAlarmInputEntry OBJECT-TYPE
SYNTAX RaisecomAlarmInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Alarm input management table entry."
INDEX { raisecomAlarmInputPortId }
::= { raisecomAlarmInputTable 1 }
RaisecomAlarmInputEntry ::= SEQUENCE {
raisecomAlarmInputPortId Integer32,
raisecomAlarmInputType INTEGER,
raisecomAlarmInputDescr OCTET STRING (SIZE (0..32)),
raisecomAlarmInputState INTEGER,
raisecomAlarmInputMontiorEnable INTEGER
}
raisecomAlarmInputPortId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Alarm Input port id."
::= { raisecomAlarmInputEntry 1 }
raisecomAlarmInputType OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Alarm type code. 0 means that this port is unused."
::= { raisecomAlarmInputEntry 2 }
raisecomAlarmInputDescr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Alarm type description."
::= { raisecomAlarmInputEntry 3 }
raisecomAlarmInputState OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
abnormal(2),
null(3),
missing(4),
unknown(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "State of this input port."
::= { raisecomAlarmInputEntry 4 }
raisecomAlarmInputMontiorEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "enable or disable the function of the port environment monitor , default is disable."
DEFVAL {disable}
::= { raisecomAlarmInputEntry 5 }
-- raisecomDeviceAlarm
raisecomPowerMissTrap NOTIFICATION-TYPE
OBJECTS {raisecomPowerDeviceIndex}
STATUS current
DESCRIPTION "Power device missing notification."
::= { raisecomDeviceAlarm 1 }
raisecomPowerFoundTrap NOTIFICATION-TYPE
OBJECTS {raisecomPowerDeviceIndex}
STATUS current
DESCRIPTION "Power device plugged-in notification."
::= { raisecomDeviceAlarm 2 }
raisecomPowerFaultTrap NOTIFICATION-TYPE
OBJECTS {raisecomPowerDeviceIndex,raisecomPowerOutputType}
STATUS current
DESCRIPTION "Power device abnormal notification."
::= { raisecomDeviceAlarm 3 }
raisecomPowerFaultRecoveredTrap NOTIFICATION-TYPE
OBJECTS {raisecomPowerDeviceIndex,raisecomPowerOutputType}
STATUS current
DESCRIPTION "Power device fault recovered notification."
::= { raisecomDeviceAlarm 4 }
raisecomFanMissTrap NOTIFICATION-TYPE
OBJECTS {raisecomFanSlotId, raisecomSubFanId}
STATUS current
DESCRIPTION "Fan missing notification."
::= { raisecomDeviceAlarm 5 }
raisecomFanFoundTrap NOTIFICATION-TYPE
OBJECTS {raisecomFanSlotId, raisecomSubFanId}
STATUS current
DESCRIPTION "Fan plugged-in notification."
::= { raisecomDeviceAlarm 6 }
raisecomSubFanFaultTrap NOTIFICATION-TYPE
OBJECTS {raisecomFanSlotId, raisecomSubFanId,
raisecomSubFanStatus, raisecomSubFanSpeed}
STATUS current
DESCRIPTION "Sub Fan abnormal notification."
::= { raisecomDeviceAlarm 7 }
raisecomSubFanFaultRecoveredTrap NOTIFICATION-TYPE
OBJECTS {raisecomFanSlotId, raisecomSubFanId,
raisecomSubFanStatus, raisecomSubFanSpeed}
STATUS current
DESCRIPTION "Sub Fan fault recovered notification."
::= { raisecomDeviceAlarm 8 }
raisecomCardMissTrap NOTIFICATION-TYPE
OBJECTS {raisecomSlotId, raisecomSlotExpectCardType}
STATUS current
DESCRIPTION
"Card missing notification. Sent when no card is detected in a slot
and expected card type for this slot is configured. It will not be
sent for power devices and fans."
::= { raisecomDeviceAlarm 9 }
raisecomCardMissCancelledTrap NOTIFICATION-TYPE
OBJECTS {raisecomSlotId}
STATUS current
DESCRIPTION "Card plugged-in notification. It will not be
sent for power devices and fans."
::= { raisecomDeviceAlarm 10 }
raisecomNonInstalledCardExist NOTIFICATION-TYPE
OBJECTS {raisecomSlotId, raisecomSlotActCardType}
STATUS current
DESCRIPTION "Non-installed card plugged-in notification.
The binded variable 'raisecomSlotActCardType' is currently unused.
It will not be sent for power devices and fans."
::= { raisecomDeviceAlarm 11 }
raisecomNonInstalledCardExistCancelled NOTIFICATION-TYPE
OBJECTS {raisecomSlotId }
STATUS current
DESCRIPTION "Non-installed card plugged-out or installed notification. It will not be
sent for power devices and fans."
::= { raisecomDeviceAlarm 12 }
raisecomCardTypeMisMatchTrap NOTIFICATION-TYPE
OBJECTS {raisecomSlotId, raisecomSlotActCardType ,
raisecomSlotExpectCardType }
STATUS current
DESCRIPTION "Actual card type and expected card type mismatched notification.
It will not be sent for power devices and fans."
::= { raisecomDeviceAlarm 13 }
raisecomCardTypeMisMatchCancelledTrap NOTIFICATION-TYPE
OBJECTS {raisecomSlotId }
STATUS current
DESCRIPTION "Actual card type and expected card type matched notification.
It will not be sent for power devices and fans."
::= { raisecomDeviceAlarm 14 }
raisecomCardFaultTrap NOTIFICATION-TYPE
OBJECTS {raisecomSlotId, raisecomSlotActCardState}
STATUS current
DESCRIPTION "Card abnormal notification. It will not be sent for power devices and fans."
::= { raisecomDeviceAlarm 15 }
raisecomCardFaultRecoveredTrap NOTIFICATION-TYPE
OBJECTS {raisecomSlotId }
STATUS current
DESCRIPTION "Card fault recovered notificaiton. It will not be sent for power devices and fans."
::= { raisecomDeviceAlarm 16 }
raisecomShelfTempertureThresholdCrossingTrap NOTIFICATION-TYPE
OBJECTS {raisecomShelfId, raisecomNETmptAlarmThreshold}
STATUS current
DESCRIPTION "Shelf temperature threshold crossing notification."
::= { raisecomDeviceAlarm 17 }
raisecomShelfTempertureRecoveredTrap NOTIFICATION-TYPE
OBJECTS {raisecomShelfId, raisecomNETmptAlarmThreshold}
STATUS current
DESCRIPTION "Shelf temperature recovered notification."
::= { raisecomDeviceAlarm 18 }
raisecomNonInstalledCardTypeTrap NOTIFICATION-TYPE
OBJECTS {raisecomSlotId, raisecomSlotActCardType}
STATUS current
DESCRIPTION "Card type of a non-installed card notification."
::= { raisecomDeviceAlarm 19 }
raisecomCardPowerFaultTrap NOTIFICATION-TYPE
OBJECTS {raisecomCardPowerSlotId, raisecomSlotActCardType ,
raisecomSlotExpectCardType }
STATUS current
DESCRIPTION "Card power fault notification."
::= { raisecomDeviceAlarm 20 }
raisecomCardPowerFaultRecoveredTrap NOTIFICATION-TYPE
OBJECTS {raisecomCardPowerSlotId, raisecomSlotActCardType ,
raisecomSlotExpectCardType }
STATUS current
DESCRIPTION "Card power fault recovered notification."
::= { raisecomDeviceAlarm 21 }
raisecomExternalAlarmTrap NOTIFICATION-TYPE
OBJECTS {raisecomAlarmInputPortId, raisecomAlarmInputType,
raisecomAlarmInputDescr, raisecomAlarmInputState}
STATUS current
DESCRIPTION "External alarm notification."
::= { raisecomDeviceAlarm 22 }
raisecomExternalAlarmRecoverdTrap NOTIFICATION-TYPE
OBJECTS {raisecomAlarmInputPortId, raisecomAlarmInputType,
raisecomAlarmInputDescr, raisecomAlarmInputState}
STATUS current
DESCRIPTION "External alarm recovered notification."
::= { raisecomDeviceAlarm 23 }
raisecomSubFanAgingTrap NOTIFICATION-TYPE
OBJECTS {raisecomFanSlotId, raisecomSubFanId, raisecomSubFanStatus,
raisecomSubFanSpeed,raisecomFanSpeedGear}
STATUS current
DESCRIPTION "Sub Fan aging notification."
::= { raisecomDeviceAlarm 24 }
raisecomSubFanAgingRecoveredTrap NOTIFICATION-TYPE
OBJECTS {raisecomFanSlotId, raisecomSubFanId, raisecomSubFanStatus,
raisecomSubFanSpeed,raisecomFanSpeedGear}
STATUS current
DESCRIPTION "Sub Fan aging recovered notification."
::= { raisecomDeviceAlarm 25 }
-- raisecomPowerTypeMismatchedTrap NOTIFICATION-TYPE
-- OBJECTS {raisecomPowerDeviceIndex, raisecomPowerExpectType, raisecomPowerActualType}
-- STATUS current
-- DESCRIPTION "Power type mismatched notification."
-- ::= { raisecomDeviceAlarm 26 }
-- raisecomPowerTypeMismatchedRecoveredTrap NOTIFICATION-TYPE
-- OBJECTS {raisecomPowerDeviceIndex}
-- STATUS current
-- DESCRIPTION "Power type mismatched recovered notification."
-- ::= { raisecomDeviceAlarm 27 }
raisecomPowerVoltageInputTrap NOTIFICATION-TYPE
OBJECTS {raisecomPowerDeviceIndex, raisecomPowerDeviceInputType,
raisecomPowerInputvol, raisecomPowerInputvolalarmState}
STATUS current
DESCRIPTION "Input voltage abnormal notification."
::= { raisecomDeviceAlarm 28 }
raisecomPowerVoltageInputRecoveredTrap NOTIFICATION-TYPE
OBJECTS {raisecomPowerDeviceIndex, raisecomPowerDeviceInputType,
raisecomPowerInputvol, raisecomPowerInputvolalarmState}
STATUS current
DESCRIPTION "Input voltage abnormal recovered notification, it is only meaningful for the manageable power."
::= { raisecomDeviceAlarm 29 }
raisecomPowerVoltageOutputTrap NOTIFICATION-TYPE
OBJECTS {raisecomPowerDeviceIndex, raisecomPowerOutputType,
raisecomPowerOutputvol, raisecomPowerStatus }
STATUS current
DESCRIPTION "output voltage abnormal notification, it is only meaningful for the manageable power."
::= { raisecomDeviceAlarm 30 }
raisecomPowerVoltageOutputRecoveredTrap NOTIFICATION-TYPE
OBJECTS {raisecomPowerDeviceIndex, raisecomPowerOutputType,
raisecomPowerOutputvol, raisecomPowerStatus }
STATUS current
DESCRIPTION "output voltage abnormal recovered notification, it is only meaningful for the manageable power."
::= { raisecomDeviceAlarm 31 }
raisecomPowerTemperatureTooHighTrap NOTIFICATION-TYPE
OBJECTS {raisecomPowerDeviceIndex, raisecomPowertemperature,
raisecomPowerTemperatureThres}
STATUS current
DESCRIPTION "power temperature too high notification, it is only meaningful for the manageable power."
::= { raisecomDeviceAlarm 32 }
raisecomPowerTemperatureTooHighRecoveredTrap NOTIFICATION-TYPE
OBJECTS {raisecomPowerDeviceIndex, raisecomPowertemperature,
raisecomPowerTemperatureThres}
STATUS current
DESCRIPTION "power temperature too high recovered notification, it is only meaningful for the manageable power."
::= { raisecomDeviceAlarm 33 }
raisecomCardLoadConfigFailedTrap NOTIFICATION-TYPE
OBJECTS {raisecomSlotId, raisecomSlotActCardType ,
raisecomSlotExpectCardType}
STATUS current
DESCRIPTION "Card config loading failed notification."
::= { raisecomDeviceAlarm 34 }
raisecomCardVersionMismatchTrap NOTIFICATION-TYPE
OBJECTS {raisecomSlotId, raisecomSlotActCardType ,
raisecomSlotExpectCardType}
STATUS current
DESCRIPTION "Card version mismatched notification."
::= { raisecomDeviceAlarm 35 }
raisecomCardVersionMismatchRecoveredTrap NOTIFICATION-TYPE
OBJECTS {raisecomSlotId, raisecomSlotActCardType ,
raisecomSlotExpectCardType}
STATUS current
DESCRIPTION "Card version-mismatch recovered notification."
::= { raisecomDeviceAlarm 36 }
END
|