summaryrefslogtreecommitdiff
path: root/MIBS/poweralert/TRIPPLITE-MIB
blob: c9af70686fa51a0fce81d421cca7363ae22f87b6 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
TRIPPLITE-MIB DEFINITIONS ::= BEGIN

IMPORTS
  DisplayString,
  TruthValue,
  TimeStamp,
  TimeInterval,
  DateAndTime,
  AutonomousType,
  VariablePointer,
  RowStatus
    FROM SNMPv2-TC
  OBJECT-GROUP,
  NOTIFICATION-GROUP
    FROM SNMPv2-CONF
  MODULE-IDENTITY,
  OBJECT-IDENTITY,
  OBJECT-TYPE,
  NOTIFICATION-TYPE,
  Gauge32,
  Integer32,
  enterprises,
  IpAddress
    FROM SNMPv2-SMI
  PositiveInteger,
  NonNegativeInteger
    FROM UPS-MIB;

tripplite MODULE-IDENTITY
  LAST-UPDATED "200904270000Z"
  ORGANIZATION "Tripplite Inc"
  CONTACT-INFO
    "Mike Delgroso
    Tripplite, Inc.
    1111 W. 35th St.
    Chicago, IL 60609"
  DESCRIPTION
    "This MIB module defines MIB objects which provide mechanisms for
    remote management capabilities of Tripplite PowerAlert and related
    software."
  REVISION "200904270000Z"
  DESCRIPTION
    "Added tlUpsAlarmOutputCurrentChanged well known alarm trap"
  REVISION "200810140000Z"
  DESCRIPTION
    "Added tlUpsOutletCurrentTable and tlUpsOutletPowerTable to publish load-specific variables"
  REVISION "200809250000Z"
  DESCRIPTION
    "Added tlUpsOutletGroupTable."
  REVISION "200802010000Z"
  DESCRIPTION
	"V1 trap decode support."
  REVISION "200711300000Z"
  DESCRIPTION
	"Changed tlUpsAlarmTime to int to match implementation, same for tlUpsAlarmDescr to string"
  REVISION "200711290000Z"
  DESCRIPTION
	"Changed tlUpsConfigBattReplDate and tlUpsTestDate from integer back to string."
  REVISION "200708260000Z"
  DESCRIPTION
    "Migrated changes from 12.04.0034, which included Load -> Outlet."
  REVISION "200702280000Z"
  DESCRIPTION
    "Renamed Load to Outlet. Cleaned up MIB compilation errors."
  REVISION "200612120000Z"
  DESCRIPTION
    "Changed tlUpsConfigBattReplDate and tlUpsTestDate from string to integer."
  REVISION "200612060000Z"
  DESCRIPTION
    "Implement tlUpsOutletTable."
  REVISION "200606200000Z"
  DESCRIPTION
    "Implemented tlUpsAlarmTable to coincide with upsAlarmTable, but
    all for additional variables."
  REVISION "200507130000Z"
  DESCRIPTION
    "Modifications to bring MIB into compliance.  Changed OID name from
    upsLoadNumLoads to tlUpsLoadNumLoads."
  REVISION "200305160000Z"
  DESCRIPTION
    "Initial release, for PowerAlert Version 12."
  ::= { enterprises 850 }


--------------------------------------------------------------------------
-- Enumerations
--------------------------------------------------------------------------

tlEnumerations OBJECT IDENTIFIER  ::= { tripplite 2 }

tlOperatingSystems OBJECT IDENTIFIER ::= { tlEnumerations 1 }

hpux9 OBJECT IDENTIFIER   ::= { tlOperatingSystems 1 }

sunos4 OBJECT IDENTIFIER  ::= { tlOperatingSystems 2 }

solaris OBJECT IDENTIFIER   ::= { tlOperatingSystems 3 }

osf OBJECT IDENTIFIER   ::= { tlOperatingSystems 4 }

ultrix OBJECT IDENTIFIER  ::= { tlOperatingSystems 5 }

hpux10 OBJECT IDENTIFIER  ::= { tlOperatingSystems 6 }

netbsd1 OBJECT IDENTIFIER   ::= { tlOperatingSystems 7 }

freebsd OBJECT IDENTIFIER   ::= { tlOperatingSystems 8 }

irix OBJECT IDENTIFIER  ::= { tlOperatingSystems 9 }

linux OBJECT IDENTIFIER   ::= { tlOperatingSystems 10 }

bsdi OBJECT IDENTIFIER  ::= { tlOperatingSystems 11 }

openbsd OBJECT IDENTIFIER   ::= { tlOperatingSystems 12 }

win32 OBJECT IDENTIFIER   ::= { tlOperatingSystems 13 }

hpux11 OBJECT IDENTIFIER  ::= { tlOperatingSystems 14 }

win9x OBJECT IDENTIFIER   ::= { tlOperatingSystems 50 }

winnt OBJECT IDENTIFIER   ::= { tlOperatingSystems 51 }

solspark OBJECT IDENTIFIER  ::= { tlOperatingSystems 52 }

solintel OBJECT IDENTIFIER  ::= { tlOperatingSystems 53 }

aix OBJECT IDENTIFIER   ::= { tlOperatingSystems 54 }

sco OBJECT IDENTIFIER   ::= { tlOperatingSystems 55 }

osx OBJECT IDENTIFIER   ::= { tlOperatingSystems 56 }

unknown OBJECT IDENTIFIER   ::= { tlOperatingSystems 255 }


--------------------------------------------------------------------------
-- UPS Device
--------------------------------------------------------------------------

tlUPS OBJECT IDENTIFIER   ::= { tripplite 100 }

tlUpsObjects OBJECT IDENTIFIER  ::= { tlUPS 1 }

tlUpsIdent OBJECT IDENTIFIER  ::= { tlUpsObjects 1 }

tlUpsIdentUpsSoftwareChecksum OBJECT-TYPE
  SYNTAX Integer32
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "A checksum for the UPS fostware."
  ::= { tlUpsIdent 1 }

tlUpsIdentSerialNum OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "Serial number for the UPS."
  ::= { tlUpsIdent 2 }

tlUpsIdentID OBJECT-TYPE
  SYNTAX Integer32 (0..65535)
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "A user-supplied ID for the UPS."
  ::= { tlUpsIdent 3 }

tlUpsSnmpCardSerialNum OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "Serial number for the UPS."
  ::= { tlUpsIdent 4 }


tlUpsBattery OBJECT IDENTIFIER  ::= { tlUpsObjects 2 }

tlUpsBatteryAge OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The age of the battery, in the format YYYYMMDD.  This is equal to
    the current date minus tlConfigBattReplDate."
  ::= { tlUpsBattery 1 }


tlUpsTemperatureF OBJECT-TYPE
  SYNTAX Integer32
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The temperature of the battery, in Farenheight degrees.  This is
    calculated from upsBatteryTemperature, which is in Celsius degrees."
  ::= { tlUpsBattery 2 }


tlUpsInput OBJECT IDENTIFIER  ::= { tlUpsObjects 3 }

tlUpsOutput OBJECT IDENTIFIER   ::= { tlUpsObjects 4 }

tlUpsBypass OBJECT IDENTIFIER   ::= { tlUpsObjects 5 }

tlUpsAlarm OBJECT IDENTIFIER  ::= { tlUpsObjects 6 }

tlUpsAlarmsPresent OBJECT-TYPE
  SYNTAX Gauge32
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The present number of active alarm conditions."
  ::= { tlUpsAlarm 1 }
  
tlUpsAlarmTable OBJECT-TYPE
  SYNTAX SEQUENCE OF TlUpsAlarmEntry
  MAX-ACCESS not-accessible
  STATUS current
  DESCRIPTION
    "A list of alarm table entries."
  ::= { tlUpsAlarm 2 }
  
tlUpsAlarmEntry OBJECT-TYPE
  SYNTAX TlUpsAlarmEntry
  MAX-ACCESS not-accessible
  STATUS current
  DESCRIPTION
    "An entry containing information applicable to a particular alarm."
  INDEX { tlUpsAlarmId }
  ::= { tlUpsAlarmTable 1 }
    
TlUpsAlarmEntry ::= SEQUENCE {
  tlUpsAlarmId         PositiveInteger,
  tlUpsAlarmDescr      AutonomousType,
  tlUpsAlarmTime       TimeStamp,
  tlUpsAlarmDetail     DisplayString,
  tlUpsAlarmDeviceId   PositiveInteger,
  tlUpsAlarmDeviceName DisplayString,
  tlUpsAlarmLocation   DisplayString,
  tlUpsAlarmGroup      INTEGER,
  tlUpsAlarmIp         IpAddress,
  tlUpsAlarmMac        DisplayString
}

tlUpsAlarmId OBJECT-TYPE
  SYNTAX PositiveInteger
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "A unique identifier for an alarm condition."
  ::= { tlUpsAlarmEntry 1 }
  
tlUpsAlarmDescr OBJECT-TYPE
  SYNTAX STRING
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "A description of the alarm condition."
  ::= { tlUpsAlarmEntry 2 }
  
tlUpsAlarmTime OBJECT-TYPE
  SYNTAX INTEGER
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The value of sysUpTime when the alarm condition was detected."
  ::= { tlUpsAlarmEntry 3 }
  
tlUpsAlarmDetail OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "A textual description of the alarm condition."
  ::= { tlUpsAlarmEntry 4 }
  
tlUpsAlarmDeviceId OBJECT-TYPE
  SYNTAX PositiveInteger
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "A numeric identifier for the device on which the alarm is active."
  ::= { tlUpsAlarmEntry 5 }
  
tlUpsAlarmDeviceName OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "A string identifier for the device on which the alarm is active."
  ::= { tlUpsAlarmEntry 6 }
  
tlUpsAlarmLocation OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The location of the device on which the alarm is active."
  ::= { tlUpsAlarmEntry 7 }
  
tlUpsAlarmGroup OBJECT-TYPE
  SYNTAX INTEGER {
      critical(1),
      warning(2),
      info(3),
      status(4),
      offline(5),
      custom(6) }
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The category/group of this alarm."
  ::= { tlUpsAlarmEntry 8 }

tlUpsAlarmIp OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The originating IP address associated with this alarm."
  ::= { tlUpsAlarmEntry 9 }

tlUpsAlarmMac OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The originating mac address associated with this alarm."
  ::= { tlUpsAlarmEntry 10 }

tlUpsWellKnownAlarms OBJECT IDENTIFIER  ::= { tlUpsAlarm 3 }

tlUpsAlarmPrimaryPowerOutage OBJECT-IDENTITY
    STATUS     current
    DESCRIPTION
            "The primary power source is not present."
    ::= { tlUpsWellKnownAlarms 1 }

tlUpsAlarmSecondaryPowerOutage OBJECT-IDENTITY
    STATUS     current
    DESCRIPTION
            "The secondary power source is not present."
    ::= { tlUpsWellKnownAlarms 2 }
    
tlUpsAlarmLoadLevelAboveThreshold OBJECT-IDENTITY
  STATUS current
  DESCRIPTION
    "The load level is above the designated threshold."
  ::= { tlUpsWellKnownAlarms 3 }

tlUpsAlarmOutputCurrentChanged OBJECT-IDENTITY
  STATUS current
  DESCRIPTION
    "The output current changed from its last known value."
  ::= { tlUpsWellKnownAlarms 4 }

tlUpsAlarmDevName OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS deprecated
  DESCRIPTION
    "The name of the device, tlDevName, corresponding to the device that is
    associated with this alarm."
  ::= { tlUpsAlarm 7 }

tlUpsAlarmDevLocation OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS deprecated
  DESCRIPTION
    "The location of the device, tlDevLocation, corresponding to the device
    that is associated with this alarm."
  ::= { tlUpsAlarm 8 }

tlUpsAlarmCategory OBJECT-TYPE
  SYNTAX Integer32
  MAX-ACCESS read-only
  STATUS deprecated
  DESCRIPTION
    "The category, tlDevEvtCategory, of this alarm."
  ::= { tlUpsAlarm 9 }



tlUpsTest OBJECT IDENTIFIER   ::= { tlUpsObjects 7 }

tlUpsTestDate OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The date of the last self-test run on the ups, in the
    format YYYYMMDD."
  ::= { tlUpsTest 1 }

tlUpsTestResultsDetail OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "Result of the last self-test run on the ups."
  ::= { tlUpsTest 2 }

tlUpsControl OBJECT IDENTIFIER  ::= { tlUpsObjects 8 }

tlUpsWatchdogSupported OBJECT-TYPE
  SYNTAX TruthValue
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "Indicates whether or not this UPS supports a watchdog reboot."
  ::= { tlUpsControl 1 }


tlUpsWatchdogSecsBeforeReboot OBJECT-TYPE
  SYNTAX NonNegativeInteger
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "The maximum number of seconds that can expire between polls that
    the engine makes to the UPS for data.  If this time runs out, then
    the UPS will cycle its outputs.  Set this to zero to turns disable
    this feature."
  ::= { tlUpsControl 2 }

tlUpsWellKnownControls OBJECT IDENTIFIER  ::= { tlUpsControl 3 }

tlUpsControlSelfTest OBJECT-TYPE
  SYNTAX TruthValue
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "Set to TRUE to initiate Self Test"
  ::= { tlUpsWellKnownControls 1 }
  
tlUpsControlRamp OBJECT-TYPE
  SYNTAX TruthValue
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "Set to TRUE to initiate Ramp"
  ::= { tlUpsWellKnownControls 2 }
  
tlUpsControlShed OBJECT-TYPE
  SYNTAX TruthValue
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "Set to TRUE to initiate Shed"
  ::= { tlUpsWellKnownControls 3 }
  
tlUpsControlUpsOn OBJECT-TYPE
  SYNTAX TruthValue
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "Set to TRUE to turn UPS on"
  ::= { tlUpsWellKnownControls 4 }

tlUpsControlUpsOff OBJECT-TYPE
  SYNTAX TruthValue
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "Set to TRUE to turn UPS off"
  ::= { tlUpsWellKnownControls 5 }
  
tlUpsConfig OBJECT IDENTIFIER   ::= { tlUpsObjects 9 }

tlUpsConfigBattReplDate OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "The date on which the battery was last replaced, in the format
    YYYYMMDD."
  ::= { tlUpsConfig 1 }

tlUpsConfigTftpGetAddr OBJECT-TYPE
  SYNTAX IpAddress
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "The IP address of the TFTP server you wish to acquire a config ini file from, non persistent, 0.0.0.0 when empty"
  ::= { tlUpsConfig 2 }

tlUpsConfigTftpGetAcction OBJECT-TYPE
  SYNTAX INTEGER {
      get(1),
      getting(2),
      idle(3) }
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "setting this entry to get(1) will start a down load from the specified address, during the download this entry
    will read getting(2), when finished, the card will reboot to the new ini supplied parms. At all other times this 
    entry will read idle(3)"
  ::= { tlUpsConfig 3 }


tlUpsOutlet OBJECT IDENTIFIER   ::= { tlUpsObjects 10 }

tlUpsOutletNumOutlets OBJECT-TYPE
  SYNTAX NonNegativeInteger
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The number of available Outlets in this device."
  ::= { tlUpsOutlet 1 }

tlUpsOutletTable OBJECT-TYPE
  SYNTAX SEQUENCE OF TlUpsOutletEntry
  MAX-ACCESS not-accessible
  STATUS current
  DESCRIPTION
    "A list of all device Outlets for all devices."
  ::= { tlUpsOutlet 2 }

tlUpsOutletEntry OBJECT-TYPE
  SYNTAX TlUpsOutletEntry
  MAX-ACCESS not-accessible
  STATUS current
  DESCRIPTION
    "An entry containing Outlet information applicable to a particular
    device managed by this agent."
  INDEX {
    tlUpsOutletIndex }
  ::= { tlUpsOutletTable 1 }

TlUpsOutletEntry ::= SEQUENCE {
  tlUpsOutletIndex        PositiveInteger,
  tlUpsOutletState        INTEGER,
  tlUpsOutletType         Integer32,
  tlUpsOutletControl      INTEGER,
  tlUpsOutletName         DisplayString,
  tlUpsOutletRampAction   INTEGER,
  tlUpsOutletRampDataType INTEGER,
  tlUpsOutletRampData     Integer32,
  tlUpsOutletShedAction   INTEGER,
  tlUpsOutletShedDataType INTEGER,
  tlUpsOutletShedData     Integer32,
  tlUpsOutletGroupNdx     Integer32 }

tlUpsOutletIndex OBJECT-TYPE
  SYNTAX PositiveInteger
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "This is the index number of this Outlet for the device
    indicated by tlDeviceIndex."
  ::= { tlUpsOutletEntry 1 }

tlUpsOutletState OBJECT-TYPE
  SYNTAX INTEGER {
      unknown(0),
      off(1),
      on(2) }
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The current state of the Outlet."
  ::= { tlUpsOutletEntry 2 }

tlUpsOutletType OBJECT-TYPE
  SYNTAX Integer32
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "This is a bit field that indicates the type of this Outlet.

    Bit   Display
     0    Battery Protected
     1    Controllable
     2
     3
     4
     5
     6
     7
     8
     9
    10
    11
    12
    13
    14
    15
    "
  ::= { tlUpsOutletEntry 3 }

tlUpsOutletControl OBJECT-TYPE
  SYNTAX INTEGER {
      turnOff(1),
      turnOn(2),
      cycle(3) }
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "Controls the state of the Outlet."
  ::= { tlUpsOutletEntry 4 }

tlUpsOutletName OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "A string identifying the devices attached to the
    output(s) of the device."
  ::= { tlUpsOutletEntry 5 }


tlUpsOutletRampAction OBJECT-TYPE
  SYNTAX INTEGER {
      remainOff(0),
      turnOnAfterDelay(1)
   }
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "The ramp action to take on the Outlet."
  ::= { tlUpsOutletEntry 6 }

tlUpsOutletRampDataType OBJECT-TYPE
  SYNTAX INTEGER {
      delayInSeconds(0)
   }
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "The type of data associated with ramp action."
  ::= { tlUpsOutletEntry 7 }

tlUpsOutletRampData OBJECT-TYPE
  SYNTAX Integer32
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "The data value associated with type of ramp data."
  ::= { tlUpsOutletEntry 8 }

tlUpsOutletShedAction OBJECT-TYPE
  SYNTAX INTEGER {
      remainOn(0),
      turnOffAfterDelay(1)
   }
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "The shed action to take on the Outlet."
  ::= { tlUpsOutletEntry 9 }

tlUpsOutletShedDataType OBJECT-TYPE
  SYNTAX INTEGER {
      delayInSeconds(0)
   }
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "The type of data associated with shed action."
  ::= { tlUpsOutletEntry 10 }

tlUpsOutletShedData OBJECT-TYPE
  SYNTAX Integer32
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "The data value associated with type of shed data."
  ::= { tlUpsOutletEntry 11 }

tlUpsOutletGroupNdx OBJECT-TYPE
  SYNTAX Integer32
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "tlUpsOutletGroupIndex of corresponding outlet group, or 0 if ungrouped."
  ::= { tlUpsOutletEntry 12 }


tlUpsOutletCurrentTable OBJECT-TYPE
  SYNTAX SEQUENCE OF TlUpsOutletCurrentEntry
  MAX-ACCESS not-accessible
  STATUS current
  DESCRIPTION
    "A list of load currents."
  ::= { tlUpsOutlet 3 }
  
tlUpsOutletCurrentEntry OBJECT-TYPE
  SYNTAX TlUpsOutletCurrentEntry
  MAX-ACCESS not-accessible
  STATUS current
  DESCRIPTION
    "An entry containing Outlet current information applicable to a particular
    device managed by this agent."
  INDEX {
    tlUpsOutletCurrentIndex }
  ::= { tlUpsOutletCurrentTable 1 }

TlUpsOutletCurrentEntry ::= SEQUENCE {
  tlUpsOutletCurrentIndex      PositiveInteger,
  tlUpsOutletCurrentValue      PositiveInteger }

tlUpsOutletCurrentIndex OBJECT-TYPE
  SYNTAX PositiveInteger
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "This is the index number of this Outlet."
  ::= { tlUpsOutletCurrentEntry 1 }

tlUpsOutletCurrentValue OBJECT-TYPE
  SYNTAX PositiveInteger
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The value of this outlet's current, represented as 0.1A"
  ::= { tlUpsOutletCurrentEntry 2 }


tlUpsOutletPowerTable OBJECT-TYPE
  SYNTAX SEQUENCE OF TlUpsOutletPowerEntry
  MAX-ACCESS not-accessible
  STATUS current
  DESCRIPTION
    "A list of load power."
  ::= { tlUpsOutlet 4 }
  
tlUpsOutletPowerEntry OBJECT-TYPE
  SYNTAX TlUpsOutletPowerEntry
  MAX-ACCESS not-accessible
  STATUS current
  DESCRIPTION
    "An entry containing Outlet power information applicable to a particular
    device managed by this agent."
  INDEX {
    tlUpsOutletPowerIndex }
  ::= { tlUpsOutletPowerTable 1 }

TlUpsOutletPowerEntry ::= SEQUENCE {
  tlUpsOutletPowerIndex      PositiveInteger,
  tlUpsOutletPowerValue      PositiveInteger }

tlUpsOutletPowerIndex OBJECT-TYPE
  SYNTAX PositiveInteger
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "This is the index number of this Outlet."
  ::= { tlUpsOutletPowerEntry 1 }

tlUpsOutletPowerValue OBJECT-TYPE
  SYNTAX PositiveInteger
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The value of this outlet's power in watts."
  ::= { tlUpsOutletPowerEntry 2 }


tlUpsOutletGroup OBJECT IDENTIFIER   ::= { tlUpsObjects 11 }

tlUpsOutletNumOutletGroups OBJECT-TYPE
  SYNTAX NonNegativeInteger
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The number of available Outlet Groups in this device."
  ::= { tlUpsOutletGroup 1 }

tlUpsOutletGroupTable OBJECT-TYPE
  SYNTAX SEQUENCE OF TlUpsOutletGroupEntry
  MAX-ACCESS not-accessible
  STATUS current
  DESCRIPTION
    "A list of device outlet group entries. The number of entries is
    given by the value of tlUpsOutletNumOutletGroups."
  ::= { tlUpsOutletGroup 2 }
  
tlUpsOutletGroupEntry OBJECT-TYPE
  SYNTAX TlUpsOutletGroupEntry
  MAX-ACCESS not-accessible
  STATUS current
  DESCRIPTION
    "An entry containing outlet group information applicable
     to a particular device managed by this agent"
  INDEX { tlUpsOutletGroupIndex }
  ::= { tlUpsOutletGroupTable 1 }

TlUpsOutletGroupEntry ::= SEQUENCE {
  tlUpsOutletGroupIndex     PositiveInteger,
  tlUpsOutletGroupUnused	Integer32,
  tlUpsOutletGroupName      DisplayString,
  tlUpsOutletGroupDesc      DisplayString,
  tlUpsOutletGroupState     INTEGER,
  tlUpsOutletGroupControl   INTEGER }

tlUpsOutletGroupIndex OBJECT-TYPE
  SYNTAX PositiveInteger
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "This is the index number of this load group for the device."
  ::= { tlUpsOutletGroupEntry 1 }

tlUpsOutletGroupUnused OBJECT-TYPE
  SYNTAX Integer32
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "Unused placeholder"
  ::= { tlUpsOutletGroupEntry 2 }

tlUpsOutletGroupName OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "The name of this outlet group."
  ::= { tlUpsOutletGroupEntry 3 }

tlUpsOutletGroupDesc OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "A description for this outlet group."
  ::= { tlUpsOutletGroupEntry 4 }

tlUpsOutletGroupState OBJECT-TYPE
  SYNTAX INTEGER {
      unknown(0),
      off(1),
      on(2),
      mixed(3) }
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The current state of the outlet group."
  ::= { tlUpsOutletGroupEntry 5 }

tlUpsOutletGroupControl OBJECT-TYPE
  SYNTAX INTEGER {
      turnOff(1),
      turnOn(2),
      cycle(3) }
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "Controls the state of every outlet associated with the group."
  ::= { tlUpsOutletGroupEntry 6 }


tlUpsTraps              OBJECT IDENTIFIER ::= { tlUPS 2 }

tlUpsTrapAlarmEntryAddedV1 TRAP-TYPE
    ENTERPRISE tlUpsTraps
    VARIABLES { tlUpsAlarmId, tlUpsAlarmDescr, tlUpsAlarmDetail, tlUpsAlarmDeviceId,
                tlUpsAlarmDeviceName, tlUpsAlarmLocation, tlUpsAlarmGroup }
    DESCRIPTION
            "This trap is sent each time an alarm is inserted into
            to the alarm table."
    --#SUMMARY "UPS Alarm: %s - %s."
    --#ARGUMENTS {6, 2}
    --#SEVERITY WARNING
 ::= 3

tlUpsTrapAlarmEntryAdded NOTIFICATION-TYPE
    OBJECTS { tlUpsAlarmId, tlUpsAlarmDescr, tlUpsAlarmDetail, tlUpsAlarmDeviceId,
              tlUpsAlarmDeviceName, tlUpsAlarmLocation, tlUpsAlarmGroup }
    STATUS  current
    DESCRIPTION
            "This trap is sent each time an alarm is inserted into
            to the alarm table."
    --#SUMMARY "UPS Alarm: %s - %s."
    --#ARGUMENTS {6, 2}
    --#SEVERITY WARNING
    ::= { tlUpsTraps 3 }

tlUpsTrapAlarmEntryRemovedV1 TRAP-TYPE
    ENTERPRISE tlUpsTraps
    VARIABLES { tlUpsAlarmId, tlUpsAlarmDescr, tlUpsAlarmDetail, tlUpsAlarmDeviceId,
                tlUpsAlarmDeviceName, tlUpsAlarmLocation, tlUpsAlarmGroup }
    DESCRIPTION
            "This trap is sent each time an alarm is removed from
            the alarm table."
    --#SUMMARY "UPS Alarm: %s - %s."
    --#ARGUMENTS {6, 2}
    --#SEVERITY WARNING
 ::= 4

tlUpsTrapAlarmEntryRemoved NOTIFICATION-TYPE
    OBJECTS { tlUpsAlarmId, tlUpsAlarmDescr, tlUpsAlarmDetail, tlUpsAlarmDeviceId,
              tlUpsAlarmDeviceName, tlUpsAlarmLocation, tlUpsAlarmGroup }
    STATUS  current
    DESCRIPTION
            "This trap is sent each time an alarm is removed from
            the alarm table."
    --#SUMMARY "UPS Alarm: %s - %s."
    --#ARGUMENTS {6, 2}
    --#SEVERITY WARNING
    ::= { tlUpsTraps 4 }


--------------------------------------------------------------------------
-- EnviroSense Device
--------------------------------------------------------------------------

tlEnviroSense OBJECT IDENTIFIER   ::= { tripplite 101 }

tlEnvEnvironment OBJECT IDENTIFIER   ::= { tlEnviroSense 1 }

tlEnvTemperatureData OBJECT IDENTIFIER   ::= { tlEnvEnvironment 1 }

tlEnvTemperatureC OBJECT-TYPE
  SYNTAX Integer32
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The ambient temperature (C)."
  ::= { tlEnvTemperatureData 1 }

tlEnvTemperatureF OBJECT-TYPE
  SYNTAX Integer32
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The ambient temperature (F)."
  ::= { tlEnvTemperatureData 2 }

tlEnvTemperatureLowLimit OBJECT-TYPE
  SYNTAX Integer32
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "The lower alarm limit for ambient temperature (F)."
  ::= { tlEnvTemperatureData 3 }

tlEnvTemperatureHighLimit OBJECT-TYPE
  SYNTAX Integer32
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "The upper alarm limit for ambient temperature (F)."
  ::= { tlEnvTemperatureData 4 }

tlEnvTemperatureInAlarm OBJECT-TYPE
  SYNTAX TruthValue
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "Indicates whether or not temperature is in alarm."
  ::= { tlEnvTemperatureData 5 }

tlEnvHumidityData OBJECT IDENTIFIER   ::= { tlEnvEnvironment 2 }

tlEnvHumidity OBJECT-TYPE
  SYNTAX Integer32
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The ambient humidity (%)."
  ::= { tlEnvHumidityData 1 }

tlEnvHumidityLowLimit OBJECT-TYPE
  SYNTAX Integer32
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "The lower alarm limit for ambient humidity (%)."
  ::= { tlEnvHumidityData 2 }

tlEnvHumidityHighLimit OBJECT-TYPE
  SYNTAX Integer32
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "The upper alarm limit for ambient humidity (%)."
  ::= { tlEnvHumidityData 3 }

tlEnvHumidityInAlarm OBJECT-TYPE
  SYNTAX TruthValue
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "Indicates whether or not humidity is in alarm."
  ::= { tlEnvHumidityData 4 }

tlEnvContacts OBJECT IDENTIFIER  ::= { tlEnviroSense 2 }

tlEnvContactTable OBJECT-TYPE
  SYNTAX SEQUENCE OF TlEnvContactEntry
  MAX-ACCESS not-accessible
  STATUS current
  DESCRIPTION
    "A table of contacts."
  ::= { tlEnvContacts 1 }

tlEnvContactEntry OBJECT-TYPE
  SYNTAX TlEnvContactEntry
  MAX-ACCESS not-accessible
  STATUS current
  DESCRIPTION
    "An entry containing information applicable to a particular contact."
  INDEX {
    tlEnvContactIndex }
  ::= { tlEnvContactTable 1 }

TlEnvContactEntry ::= SEQUENCE {
  tlEnvContactIndex    PositiveInteger,
  tlEnvContactName     DisplayString,
  tlEnvContactStatus   INTEGER,
  tlEnvContactConfig   INTEGER }

tlEnvContactIndex OBJECT-TYPE
  SYNTAX PositiveInteger
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The table row index for the contact."
  ::= { tlEnvContactEntry 1 }

tlEnvContactName OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "The name or description of the contact."
  ::= { tlEnvContactEntry 2 }

tlEnvContactStatus OBJECT-TYPE
  SYNTAX INTEGER {
      normal(0),
      alarm(1) }
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
    "The current status of the contact."
  ::= { tlEnvContactEntry 3 }

tlEnvContactConfig OBJECT-TYPE
  SYNTAX INTEGER {
      normallyOpen(0),
      normallyClosed(1) }
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
    "The configuration of the contact."
  ::= { tlEnvContactEntry 4 }


--------------------------------------------------------------------------
-- KVM over IP Device
--------------------------------------------------------------------------

-- this is a 3rd party MIB structure located at { tripplite 102 }

--------------------------------------------------------------------------
-- Conformance definitions
--------------------------------------------------------------------------

tlConformance OBJECT IDENTIFIER   ::= { tripplite 20 }

tlCompliances OBJECT IDENTIFIER   ::= { tlConformance 1 }

tlGroups OBJECT IDENTIFIER  ::= { tlConformance 2 }

tlSubsetGroups OBJECT IDENTIFIER  ::= { tlGroups 1 }

tlBasicGroups OBJECT IDENTIFIER   ::= { tlGroups 2 }

tlFullGroups OBJECT IDENTIFIER  ::= { tlGroups 3 }


tlV11Groups OBJECT IDENTIFIER  ::= { tlGroups 4 }

tlDeprecatedV11Group OBJECT-GROUP
  OBJECTS {
    upsTrapCode,
    upsTrapDescription }
  STATUS obsolete
  DESCRIPTION
    "The tlDeprecatedV11Group defines objects which were used by
    Sinetica SNMP cards on Tripplite UPSs and PowerAlert version 11.
    These objects are currently only used when
    tlEngineLegacySNMPSupport == true."
  ::= { tlV11Groups 1 }

tlDeprecatedV11NotificationsGroup NOTIFICATION-GROUP
  NOTIFICATIONS {
    tlV11upsCritical,
    tlV11upsWarning,
    tlV11upsInformation,
    tlV11upsAlarmCleared,
    tlV11upsAgentStarted,
    tlV11upsAgentStopped }
  STATUS obsolete
  DESCRIPTION
    "The tlDeprecatedV11NotificationsGroup defines PowerAlert version 11
    notifications.  These notifications are being deprecated, but may
    still be used when tlEngineLegacySNMPSupport = true."
  ::= { tlV11Groups 2 }

tlObsoleteV11Group OBJECT-GROUP
  OBJECTS {
    upsReceptaclesNumReceptacles,
    upsReceptacleIndex,
    upsReceptacleType,
    upsReceptacleStatus,
    upsReceptacleControl,
    upsEnvTemperature,
    upsEnvHumidity,
    upsContactIndex,
    upsContactName,
    upsContactStatus,
    upsContactConfig }
  STATUS obsolete
  DESCRIPTION
    "The tlObsoleteV11Group defines objects which were used by
    Sinetica SNMP cards on Tripplite UPSs.  Most of these objects are obsolete."
  ::= { tlV11Groups 3 }


-- tlUpsCompliances OBJECT IDENTIFIER ::= { tlCompliances 1 }
--
-- tlUpsSubsetCompliance MODULE-COMPLIANCE
--   STATUS current
--   DESCRIPTION
--     "Description"
--   MODULE == this module
--     MANDATORY-GROUPS {
--       groups}
--
--   OBJECT tlUpsOBJECT1
--   SYNTAX INTEGER {
--     enum1(1),
--     enum2(2)
--   }
--   DESCRIPTION
--     "Description"
--
--   OBJECT tlUpsOBJECT2
--   DESCRIPTION
--     "Description"
--
--   OBJECT tlUpsOBJECT3
--   MIN-ACCESS read-only
--   DESCRIPTION
--     "Description"
--   ::= { tlUpsCompliances 1 }
--
-- tlUpsBasicCompliance MODULE-COMPLIANCE
--   ...
--   ::= { tlUpsCompliances 2 }
--
-- tlUpsFullCompliance MODULE-COMPLIANCE
--   ...
--   ::= { tlUpsCompliances 3 }
--
-- units of conformance
--
-- summary at a glance:
--                                      subset  basic   full
--tlUpsIdentUPSSoftwareChecksum                         x
--tlUpsIdentSerialNum                                   x
--tlUpsIdentID                                          x
--
--tlUpsBatteryAge                                       x
--tlUpsBatteryTemperatureF                              x
--
--tlUpsAlarm
--
--tlUpsTestDate                                         x
--
--tlUpsWatchdogSupported                                x
--tlUpsWatchdogSecsBeforeReboot                         x
--
--tlUpsConfigBattReplDate                               x
--
--tlUpsLoadNumLoads                                     x
--
--tlUpsNotificationCode                                         x
--tlUpsNotificationDescription                                  x
--
--tlUpsCritical                                         x
--tlUpsWarning                                          x
--tlUpsInformation                                      x
--tlUpsAlarmCleared                                     x
--tlUpsAgentStarted                                     x
--tlUpsAgentStopped                                     x
--
--tlUpsSubsetGroups OBJECT IDENTIFIER   ::= { tlSubsetGroups 100 }
--
--tlUpsBasicGroups OBJECT IDENTIFIER  ::= { tlBasicGroups 100 }

tlUpsFullGroups OBJECT IDENTIFIER   ::= { tlFullGroups 100 }

tlUpsFullIdentGroup OBJECT-GROUP
  OBJECTS {
    tlUpsIdentUpsSoftwareChecksum,
    tlUpsIdentSerialNum,
    tlUpsIdentID }
  STATUS current
  DESCRIPTION
    "The tlUpsFullIdentGroup defines objects which are common to the Ident
    group of fully compliant Tripplite UPS's"
  ::= { tlUpsFullGroups 1 }

tlUpsFullBatteryGroup OBJECT-GROUP
  OBJECTS {
    tlUpsBatteryAge,
    tlUpsTemperatureF }
  STATUS current
  DESCRIPTION
    "The tlUpsFullBatteryGroup defines objects which are common to the Battery
    group of fully compliant Tripplite UPS's"
  ::= { tlUpsFullGroups 2 }

tlUpsFullAlarmGroup OBJECT IDENTIFIER   ::= { tlUpsFullGroups 6 }

tlUpsFullAlarmObjsGroup OBJECT-GROUP
  OBJECTS {
    tlUpsAlarmDevName,
    tlUpsAlarmDevLocation,
    tlUpsAlarmCategory }
  STATUS current
  DESCRIPTION
    "The tlUpsFullAlarmObjsGroup defines objects which are common to
    the Alarm group of fully compliant Tripplite UPS's"
  ::= { tlUpsFullAlarmGroup 1 }

--tlUpsFullAlarmsGroup NOTIFICATION-GROUP
--  NOTIFICATIONS { }
--  STATUS current
--  DESCRIPTION
--    "The tlUpsFullAlarmGroup defines notifications which are
--    common to the Alarm group of fully compliant Tripplite UPS's"
--  ::= { tlUpsFullAlarmGroup 2 }

tlUpsFullTestGroup OBJECT-GROUP
  OBJECTS {
    tlUpsTestDate,
    tlUpsTestResultsDetail }
  STATUS current
  DESCRIPTION
    "The tlUpsFullTestGroup defines objects which are common to the Test
    group of fully compliant Tripplite UPS's"
  ::= { tlUpsFullGroups 7 }

tlUpsFullControlGroup OBJECT-GROUP
  OBJECTS {
    tlUpsWatchdogSupported,
    tlUpsWatchdogSecsBeforeReboot }
  STATUS current
  DESCRIPTION
    "The tlUpsFullControlGroup defines objects which are common to the Control
    group of fully compliant Tripplite UPS's"
  ::= { tlUpsFullGroups 8 }

tlUpsFullConfigGroup OBJECT-GROUP
  OBJECTS {
    tlUpsConfigBattReplDate }
  STATUS current
  DESCRIPTION
    "The tlUpsFullConfigGroup defines objects which are common to the Config
    group of fully compliant Tripplite UPS's"
  ::= { tlUpsFullGroups 9 }

tlUpsFullOutletGroup OBJECT-GROUP
  OBJECTS {
    tlUpsOutletNumOutlets }
  STATUS current
  DESCRIPTION
    "The tlUpsFullOutletGroup defines objects which are common to the Outlet
    group of fully compliant Tripplite UPS's"
  ::= { tlUpsFullGroups 10 }

--------------------------------------------------------------------------
-- Legacy (PowerAlert version 11) objects
--
-- These objects have been published in previous Tripplite MIBs and are
-- no longer supported, except where otherwise indicated.
--------------------------------------------------------------------------

trippUPS OBJECT IDENTIFIER  ::= { tripplite 1 }

trippUpsReceptacles OBJECT IDENTIFIER   ::= { trippUPS 1 }

upsReceptaclesNumReceptacles OBJECT-TYPE
  SYNTAX NonNegativeInteger
  MAX-ACCESS read-only
  STATUS obsolete
  DESCRIPTION
    "The number of available receptacles in this device.
    This variable indicates the number of rows in the
    receptacle table."
  ::= { trippUpsReceptacles 1 }


upsReceptacleTable OBJECT-TYPE
  SYNTAX SEQUENCE OF UpsReceptacleEntry
  MAX-ACCESS not-accessible
  STATUS obsolete
  DESCRIPTION
    "A list of receptacle table entries.  The number of entries
    is given by the value of upsReceptaclesNumReceptacles."
  ::= { trippUpsReceptacles 2 }


upsReceptacleEntry OBJECT-TYPE
  SYNTAX UpsReceptacleEntry
  MAX-ACCESS not-accessible
  STATUS obsolete
  DESCRIPTION
    "An entry containing information applicable to a
    particular receptacle."
  INDEX {
    upsReceptacleIndex }
  ::= { upsReceptacleTable 1 }


UpsReceptacleEntry ::= SEQUENCE {
  upsReceptacleIndex   PositiveInteger,
  upsReceptacleType    INTEGER,
  upsReceptacleStatus  INTEGER,
  upsReceptacleControl INTEGER }


upsReceptacleIndex OBJECT-TYPE
  SYNTAX PositiveInteger
  MAX-ACCESS read-only
  STATUS obsolete
  DESCRIPTION
    "The receptacle identifier."
  ::= { upsReceptacleEntry 1 }


upsReceptacleType OBJECT-TYPE
  SYNTAX INTEGER {
      surgeOnly(1),
      batteryProtected(2),
      controllableBatteryProtected(3) }
  MAX-ACCESS read-only
  STATUS obsolete
  DESCRIPTION
    "The type of receptacle."
  ::= { upsReceptacleEntry 2 }


upsReceptacleStatus OBJECT-TYPE
  SYNTAX INTEGER {
      on(1),
      off(2),
      unknown(3) }
  MAX-ACCESS read-only
  STATUS obsolete
  DESCRIPTION
    "The status of receptacle."
  ::= { upsReceptacleEntry 3 }


upsReceptacleControl OBJECT-TYPE
  SYNTAX INTEGER {
      on(1),
      off(2),
      cycle(3) }
  MAX-ACCESS read-write
  STATUS obsolete
  DESCRIPTION
    "Setting this object to 'on' will turn on the receptacle.
    Setting this object to 'off' will turn off the receptacle.
    Setting this object to 'cycle' will turn off and then turn
    on the receptacle.  This action will only take place if the
    receptacle is controllable
    (upsReceptacleType = controllableBatteryProtected(3))."
  ::= { upsReceptacleEntry 4 }


trippUpsTrapInfo OBJECT IDENTIFIER  ::= { trippUPS 2 }

upsTrapCode OBJECT-TYPE
  SYNTAX INTEGER (0..2147483647)
  MAX-ACCESS read-only
  STATUS deprecated
  DESCRIPTION
    "A numeric code identifiying the condition that caused the trap to be sent.
    If the trap number is 104 (upsAgentStarted) or 105 (upsAgentStopped), this
    code will indicate whether the SNMP agent is software (1) or hardware (2)."
  ::= { trippUpsTrapInfo 1 }


upsTrapDescription OBJECT-TYPE
  SYNTAX DisplayString (SIZE (0..63))
  MAX-ACCESS read-only
  STATUS deprecated
  DESCRIPTION
    "The description of the trap."
  ::= { trippUpsTrapInfo 2 }


trippUpsEnvironment OBJECT IDENTIFIER   ::= { trippUPS 3 }

upsEnvTemperature OBJECT-TYPE
  SYNTAX Integer32
  MAX-ACCESS read-only
  STATUS obsolete
  DESCRIPTION
    "The ambient temperature of the EnviroSense unit (1/10 Deg C)."
  ::= { trippUpsEnvironment 1 }


upsEnvHumidity OBJECT-TYPE
  SYNTAX INTEGER (0..100)
  MAX-ACCESS read-only
  STATUS obsolete
  DESCRIPTION
    "The ambient humidity of the EnviroSense unit (% Humidity)."
  ::= { trippUpsEnvironment 2 }


trippUpsContacts OBJECT IDENTIFIER  ::= { trippUPS 4 }

upsContactTable OBJECT-TYPE
  SYNTAX SEQUENCE OF UpsContactEntry
  MAX-ACCESS not-accessible
  STATUS obsolete
  DESCRIPTION
    "A table of contacts attached to the EnviroSense unit."
  ::= { trippUpsContacts 1 }


upsContactEntry OBJECT-TYPE
  SYNTAX UpsContactEntry
  MAX-ACCESS not-accessible
  STATUS obsolete
  DESCRIPTION
    "An entry containing information applicable to a
    particular contact."
  INDEX {
    upsContactIndex }
  ::= { upsContactTable 1 }


UpsContactEntry ::= SEQUENCE {
  upsContactIndex  PositiveInteger,
  upsContactName   DisplayString,
  upsContactStatus INTEGER,
  upsContactConfig INTEGER }


upsContactIndex OBJECT-TYPE
  SYNTAX PositiveInteger
  MAX-ACCESS read-only
  STATUS obsolete
  DESCRIPTION
    "The contact identifier."
  ::= { upsContactEntry 1 }


upsContactName OBJECT-TYPE
  SYNTAX DisplayString (SIZE (0..15))
  MAX-ACCESS read-write
  STATUS obsolete
  DESCRIPTION
    "The contact name."
  ::= { upsContactEntry 2 }


upsContactStatus OBJECT-TYPE
  SYNTAX INTEGER {
      unknown(0),
      normal(1),
      alarm(2) }
  MAX-ACCESS read-only
  STATUS obsolete
  DESCRIPTION
    "The current status of the contact."
  ::= { upsContactEntry 3 }


upsContactConfig OBJECT-TYPE
  SYNTAX INTEGER {
      normallyClosed(0),
      normallyOpen(1) }
  MAX-ACCESS read-write
  STATUS obsolete
  DESCRIPTION
    "The default configuration of the contact."
  ::= { upsContactEntry 4 }


--------------------------------------------------------------------------
-- Legacy (PowerAlert version 11) traps, redefined as notifications.
--
-- These notifications define the traps used in previous Tripplite MIBs and
-- are only supported when legacy support is enabled, as indicated by
-- tlEngineLegacySNMPSupport
--------------------------------------------------------------------------

tlV11TrapsPrefix OBJECT IDENTIFIER  ::= { trippUPS 0 }

tlV11upsCritical NOTIFICATION-TYPE
  OBJECTS {
    upsTrapCode,
    upsTrapDescription }
  STATUS obsolete
  DESCRIPTION
    "UPS Critical Alarm."
  ::= { tlV11TrapsPrefix 100 }


tlV11upsWarning NOTIFICATION-TYPE
  OBJECTS {
    upsTrapCode,
    upsTrapDescription}
  STATUS obsolete
  DESCRIPTION
    "UPS Warning."
  ::= { tlV11TrapsPrefix 101 }


tlV11upsInformation NOTIFICATION-TYPE
  OBJECTS {
    upsTrapCode,
    upsTrapDescription}
  STATUS obsolete
  DESCRIPTION
    "UPS Information."
  ::= { tlV11TrapsPrefix 102 }


tlV11upsAlarmCleared NOTIFICATION-TYPE
  OBJECTS {
    upsTrapCode,
    upsTrapDescription}
  STATUS obsolete
  DESCRIPTION
    "UPS Alarm Cleared."
  ::= { tlV11TrapsPrefix 103 }


tlV11upsAgentStarted NOTIFICATION-TYPE
  OBJECTS {
    upsTrapCode,
    upsTrapDescription}
  STATUS obsolete
  DESCRIPTION
    "Agent started."
  ::= { tlV11TrapsPrefix 104 }


tlV11upsAgentStopped NOTIFICATION-TYPE
  OBJECTS {
    upsTrapCode,
    upsTrapDescription}
  STATUS obsolete
  DESCRIPTION
    "Agent stopped."
  ::= { tlV11TrapsPrefix 105 }


--------------------------------------------------------------------------
-- This is an excerpt from the TRIPPUPS-MIB used for Delta SNMP cards in
-- Tripplite UPSs.  It has major fundamental problems with OID collisions
-- and naming collosions, so it's commented out in its entirety.  It's
-- only included for historical documentation purposes.
--------------------------------------------------------------------------
--------------------------------------------------------------------------
-- BEGIN Delta SNMP MIB
--------------------------------------------------------------------------
-- ups OBJECT IDENTIFIER   ::= { trippUPS 1 }
--
-- upsIdent OBJECT IDENTIFIER  ::= { ups 1 }
--
-- upsBattery OBJECT IDENTIFIER  ::= { ups 2 }
--
-- upsInput OBJECT IDENTIFIER  ::= { ups 3 }
--
-- upsOutput OBJECT IDENTIFIER   ::= { ups 4 }
--
-- upsAlarm OBJECT IDENTIFIER  ::= { ups 6 }
--
-- upsWellKnownAlarms OBJECT IDENTIFIER  ::= { ups 7 }
--
-- upsTest OBJECT IDENTIFIER   ::= { ups 8 }
--
-- upsControl OBJECT IDENTIFIER  ::= { ups 9 }
--
-- upsConfig OBJECT IDENTIFIER   ::= { ups 10 }
--
-- The Device Identification group.
-- All objects in this group are set at device initialization and remain static.
--
-- upsIdentManufacturer OBJECT-TYPE
--   SYNTAX DisplayString (SIZE (0..31))
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The name of the UPS manufacturer."
--   ::= { upsIdent 1 }
--
--
-- upsIdentModel OBJECT-TYPE
--   SYNTAX DisplayString (SIZE (0..63))
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The UPS Model designation."
--   ::= { upsIdent 2 }
--
--
-- upsIdentUPSSoftwareVersion OBJECT-TYPE
--   SYNTAX DisplayString (SIZE (0..63))
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The UPS Firmware software version(s).  This variable
--     may or may not have the same value as
--     upsIdentAgentSoftwareVersion in some implementations."
--   ::= { upsIdent 3 }
--
--
-- upsIdentAgentSoftwareVersion OBJECT-TYPE
--   SYNTAX DisplayString (SIZE (0..63))
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The UPS agent software version.  This variable may or
--     may not have the same value as
--     upsIdentUPSSoftwareVersion in some implementations."
--   ::= { upsIdent 4 }
--
--
-- upsIdentName OBJECT-TYPE
--   SYNTAX DisplayString (SIZE (0..63))
--   ACCESS read-write
--   STATUS obsolete
--   DESCRIPTION
--     "A string identifying the UPS.  This object should be
--     set by the administrator."
--   ::= { upsIdent 5 }
--
--
-- upsIdentAttachedDevices OBJECT-TYPE
--   SYNTAX DisplayString (SIZE (0..63))
--   ACCESS read-write
--   STATUS obsolete
--   DESCRIPTION
--     "A string identifying the devices attached to the
--     output(s) of the UPS.  This object should be set by
--     the administrator."
--   ::= { upsIdent 6 }
--
--
-- The Battery group.
-- Implementation of this group is mandatory for all systems.
--
-- upsBatteryStatus OBJECT-TYPE
--   SYNTAX INTEGER {
--       unknown(1),
--       batteryNormal(2),
--       batteryLow(3),
--       batteryDepleted(4) }
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The indication of the capacity remaining in the UPS
--     system's batteries.  A value of batteryNormal
--     indicates that the batteries are fully charged.  A
--     value of batteryLow indicates that the remaining battery
--     run-time is less than or equal to
--     upsConfigMinutesRemaining.  A value of batteryDepleted
--     indicates that the UPS will be unable to sustain the
--     present load when and if the utility power is lost."
--   ::= { upsBattery 1 }
--
--
-- upsSecondsOnBattery OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "If the unit is on battery power, the elapsed time
--     since the UPS last switched to battery power, or the
--     time since the network management subsystem was last
--     restarted, whichever is less.  Zero shall be returned
--     if the unit is not on battery power. UNITS - seconds"
--   ::= { upsBattery 2 }
--
--
-- upsEstimatedMinutesRemaining OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "An estimate of the time to battery charge depletion
--     under the present load conditions if the utility power
--     were to be lost and remain off. UNITS - minutes"
--   ::= { upsBattery 3 }
--
--
-- upsBatteryChargeRemaining OBJECT-TYPE
--   SYNTAX INTEGER (0..100)
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The estimate of the battery charge remaining expressed
--     as a percent of full charge."
--   ::= { upsBattery 4 }
--
--
-- upsBatteryVoltage OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The magnitude of the present battery voltage.   UNITS  0.1 Volt DC."
--   ::= { upsBattery 5 }
--
--
--------------------------------------------------------------------------
-- Note : upsBatteryCurrent MIB variable removed by Dave Cole (SEC) on 4/24/95
-- To conform with older versions of this MIB,  {upsBattery 6 }  is reserved.
--------------------------------------------------------------------------
--
-- upsBatteryTemperature OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The ambient temperature at or near the UPS Battery.
--     UNITS degrees Centigrade"
--   ::= { upsBattery 7 }
--
--
-- the table group has one attribute of its own - the number of rows in the
-- contained table.  It also contains the table of names.
-- The Input group.
-- Implementation of this group is mandatory for all systems.
--
-- upsInputFrequency OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The present input frequency.  UNITS  0.1 Hertz"
--   ::= { upsInput 1 }
--
--
-- upsInputLineBads OBJECT-TYPE
--   SYNTAX Counter
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "A count of the number of times the input entered an
--     out-of-tolerance condition as defined by the manufacturer."
--   ::= { upsInput 2 }
--
--
-- upsInputNumLines OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The number of input lines utilized in this device.
--     This variable indicates the number of rows in the input table."
--   ::= { upsInput 3 }
--
--
-- upsInputVolt OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The magnitude of the present input voltage.
--     UNITS     RMS Volts"
--   ::= { upsInput 4 }
--
--
-- upsInputTable OBJECT-TYPE
--   SYNTAX SEQUENCE OF UpsInputEntry
--   ACCESS not-accessible
--   STATUS obsolete
--   DESCRIPTION
--     "A list of input table entries.  The number of entries
--     is given by the value of upsInputNumLines."
--   ::= { upsInput 5 }
--
--
-- upsInputEntry OBJECT-TYPE
--   SYNTAX UpsInputEntry
--   ACCESS not-accessible
--   STATUS obsolete
--   DESCRIPTION
--     "An entry containing information applicable to a
--     particular input line."
--   INDEX {
--     upsInputLineIndex }
--   ::= { upsInputTable 1 }
--
--
-- UpsInputEntry ::= SEQUENCE {
--   upsInputLineIndex INTEGER,
--   upsInputVoltage   INTEGER }
--
--
-- upsInputLineIndex OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The input line identifier."
--   ::= { upsInputEntry 1 }
--
--
-- upsInputVoltage OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The magnitude of the present input voltage.
--     UNITS     RMS Volts"
--   ::= { upsInputEntry 2 }
--
--
-- The Output group.
-- Implementation of this group is mandatory for all systems.
--
-- upsOutputSource OBJECT-TYPE
--   SYNTAX INTEGER {
--       other(1),
--       none(2),
--       normal(3),
--       bypass(4),
--       battery(5),
--       booster(6),
--       reducer(7) }
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The present source of output power."
--   ::= { upsOutput 1 }
--
--
-- upsOutputFrequency OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The present output frequency.
--     UNITS     0.1 Hertz"
--   ::= { upsOutput 2 }
--
--
-- upsOutputNumLines OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The number of output lines utilized in this device.
--     This variable indicates the number of rows in the output table."
--   ::= { upsOutput 3 }
--
--
-- upsOutputPercLoad OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The percentage of true power capacity presently being used.
--     UNITS     percent"
--   ::= { upsOutput 4 }
--
--
-- upsOutputTable OBJECT-TYPE
--   SYNTAX SEQUENCE OF UpsOutputEntry
--   ACCESS not-accessible
--   STATUS obsolete
--   DESCRIPTION
--     "A list of output table entries.  The number of
--     entries is given by the value of upsOutputNumLines."
--   ::= { upsOutput 5 }
--
--
-- upsOutputEntry OBJECT-TYPE
--   SYNTAX UpsOutputEntry
--   ACCESS not-accessible
--   STATUS obsolete
--   DESCRIPTION
--     "An entry containing information applicable to a
--     particular output line."
--   INDEX {
--     upsOutputLineIndex }
--   ::= { upsOutputTable 1 }
--
--
-- UpsOutputEntry ::= SEQUENCE {
--   upsOutputLineIndex   INTEGER,
--   upsOutputVoltage     INTEGER,
--   upsOutputCurrent     INTEGER,
--   upsOutputPower       INTEGER,
--   upsOutputPercentLoad INTEGER }
--
--
-- upsOutputLineIndex OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The output line identifier."
--   ::= { upsOutputEntry 1 }
--
--
-- upsOutputVoltage OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The present output voltage.
--     UNITS     RMS Volts"
--   ::= { upsOutputEntry 2 }
--
--
-- upsOutputCurrent OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The present output mandatory.
--     UNITS     0.1 Amp"
--   ::= { upsOutputEntry 3 }
--
--
-- upsOutputPower OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The present output true power.
--     UNITS     Watts"
--   ::= { upsOutputEntry 4 }
--
--
-- upsOutputPercentLoad OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The percentage of true power capacity presently being used.
--     UNITS     percent"
--   ::= { upsOutputEntry 5 }
--
--
-- Alarm Group
--
-- upsAlarmsPresent OBJECT-TYPE
--   SYNTAX Gauge
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The present number of active alarm conditions."
--   ::= { upsAlarm 1 }
--
--
-- upsAlarmID OBJECT-TYPE
--   SYNTAX INTEGER {
--       upsAlarmBatteryBad(1),
--       upsAlarmOnBattery(2),
--       upsAlarmLowBattery(3),
--       upsAlarmDepletedBattery(4),
--       upsAlarmTempBad(5),
--       upsAlarmOutputOverload(6),
--       upsAlarmOutputOffAsRequested(7),
--       upsAlarmOutputOff(8),
--       upsAlarmDiagnosticTestFailed(9),
--       upsAlarmCommunicationsLost(10),
--       upsAlarmShutdownPending(11),
--       upsAlarmShutdownImminent(12),
--       upsAlarmTestInProgress(13) }
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "A unique identifier for an alarm condition.  This
--     value must remain constant."
--   ::= { upsAlarm 2 }
--
--
-- upsAlarmDESCR OBJECT-TYPE
--   SYNTAX DisplayString (SIZE (0..31))
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "A reference to an alarm description object.  The
--     object references should not be accessible, but rather
--     be used to provide a unique description of the alarm
--     condition."
--   ::= { upsAlarm 3 }
--
--
-- upsAlarmTable OBJECT-TYPE
--   SYNTAX SEQUENCE OF UpsAlarmEntry
--   ACCESS not-accessible
--   STATUS obsolete
--   DESCRIPTION
--     "A list of alarm table entries.  The table consists of
--     zero, one, or may rows at any moment, depending upon
--     the number of alarm conditions in effect.  The table
--     is initially empty at agent startup.  The agent
--     creates a row in the table each time a condition is
--     detected and deletes that row when that condition no
--     longer pertains.  The agent creates the first row with
--     upsAlarmId equal to 1, and increments the value fo
--     upsAlarmId each time a new row is created, wrapping to
--     the first free value greater than or equal to 1 when
--     the maximum value of upsAlarmId would otherwise be
--     exceeded.  Consequently, after multiple operations,
--     the table may become sparse, e.g., containing entries
--     for rows 95, 100, 101, and 203 and the entries are in
--     chronological order until upsAlarmId wraps.
--
--     Alarms are named by and OBJECT IDENTIFIER,
--     upsAlarmDescr, to allow a single table to reflect well
--     known alarms plus alarms defined by a particular
--     implementation, i.e., as documented in the private
--     enterprise MIB definition for the device.  No two rows
--     will have the same value of upsAlarmDescr, since
--     alarms define conditions.  In order to meet this
--     requirement, care should be take in the definition of
--     the number of active rows in the table at any given
--     time is reflected by the value fo upsAlarms."
--   ::= { upsAlarm 4 }
--
--
-- upsAlarmEntry OBJECT-TYPE
--   SYNTAX UpsAlarmEntry
--   ACCESS not-accessible
--   STATUS obsolete
--   DESCRIPTION
--     "An entry containing information applicable to a
--     particular alarm."
--   INDEX {
--     upsAlarmId }
--   ::= { upsAlarmTable 1 }
--
--
-- UpsAlarmEntry ::= SEQUENCE {
--   upsAlarmId    INTEGER,
--   upsAlarmDescr DisplayString,
--   upsAlarmTime  TimeTicks }
--
--
-- upsAlarmId OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "A unique identifier for an alarm condition.  This
--     value must remain constant."
--   ::= { upsAlarmEntry 1 }
--
--
-- upsAlarmDescr OBJECT-TYPE
--   SYNTAX DisplayString (SIZE (0..31))
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "A reference to an alarm description object.  The
--     object references should not be accessible, but rather
--     be used to provide a unique description of the alarm
--     condition."
--   ::= { upsAlarmEntry 2 }
--
--
-- upsAlarmTime OBJECT-TYPE
--   SYNTAX TimeTicks
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The value of sysUpTime when the alarm condition was
--     detected.  If the alarm condition was detected at the
--     time of agent startup and presumable existed before
--     agent startup, the value of upsAlarmTime shall equal
--     0."
--   ::= { upsAlarmEntry 3 }
--
--
-- upsAlarmBatteryBad OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "One or more batteries have been determined to require
--     replacement."
--   ::= { upsWellKnownAlarms 1 }
--
--
-- upsAlarmOnBattery OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The UPS is drawing power from the batteries."
--   ::= { upsWellKnownAlarms 2 }
--
--
-- upsAlarmLowBattery OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The remaining battery run-time is less than or equal
--     to upsConfigMinutesRemaining."
--   ::= { upsWellKnownAlarms 3 }
--
--
-- upsAlarmDepletedBattery OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The UPS will be unable to sustain the present load
--     when and if the utility power is lost."
--   ::= { upsWellKnownAlarms 4 }
--
--
-- upsAlarmTempBad OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "A temperature is out of tolerance."
--   ::= { upsWellKnownAlarms 5 }
--
--
-- upsAlarmOutputOverload OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The output load exceeds the UPS output capacity."
--   ::= { upsWellKnownAlarms 6 }
--
--
-- upsAlarmOutputOffAsRequested OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The UPS has shutdown as commanded, i.e., the output is off."
--   ::= { upsWellKnownAlarms 7 }
--
--
-- upsAlarmUpsOutputOff OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The UPS is in the off state."
--   ::= { upsWellKnownAlarms 8 }
--
--
-- upsAlarmDiagnosticTestFailed OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The result of the last diagnostic test indicates a
--     failure."
--   ::= { upsWellKnownAlarms 9 }
--
--
-- upsAlarmCommunicationsLost OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "A problem has been encountered in the
--     communications between the agent and the UPS."
--   ::= { upsWellKnownAlarms 10 }
--
--
-- upsAlarmShutdownPending OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "A upsShutdownAfterDelay countdown is underway."
--   ::= { upsWellKnownAlarms 11 }
--
--
-- upsAlarmShutdownImminent OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "A upsShutdownAfterDelay countdown is underway."
--   ::= { upsWellKnownAlarms 12 }
--
--
-- upsAlarmTestInProgress OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "A upsShutdownAfterDelay countdown is underway."
--   ::= { upsWellKnownAlarms 13 }
--
-- Test Group
--
-- upsTestId OBJECT-TYPE
--   SYNTAX INTEGER {
--       noTestsInitiated(1),
--       abortTestInProgress(2),
--       generalSystemsTest(3),
--       checkBatteryTest(4),
--       deepBatteryCalibration(5) }
--   ACCESS read-write
--   STATUS obsolete
--   DESCRIPTION
--     "The test named by an OBJECT IDENTIFIER which
--     allows a standard mechanism for the initiation of
--     test, including the well known tests identified in
--     this document as well as those introduced by a
--     particular implementation, i.e., as
--     documented in the private enterprise MIB definition
--     for the device.
--
--     Setting this variable initiates the named test.  Sets
--     to this variable require the presence of
--     upsTestSpinLock in the same SNMP message.
--
--     The set request will be rejected with an appropriate
--     error message if the requested test cannot be
--     performed, including attempts to start a test when
--     another test is already in progress.  Tests in
--     progress may be aborted by setting this variable to
--     upsTestAbortTestInProgress.
--
--     Read operations return the value of the name of the
--     test in progress if a test is in progress or the name
--     of the last test performed if no test is in progress,
--     unless no test has bee run, in which case the well
--     known value upsTestNoTestsInitiated is returned."
--   ::= { upsTest 1 }
--
--
-- upsTestResultsSummary OBJECT-TYPE
--   SYNTAX INTEGER {
--       donePass(1),
--       doneWarning(2),
--       doneError(3),
--       aborted(4),
--       inProgress(5),
--       noTestsInitiated(6) }
--   ACCESS read-only
--   STATUS obsolete
--   DESCRIPTION
--     "The results of the mandatory or last UPS diagnostics
--     test performed.  The values for donePass(1),
--     doneWarning(2), and doneError(3) are self-documenting.
--     The value aborted(4) is returned for tests which are
--     aborted by setting the value of upsTestId to
--     upsTestAbortTestInProgress.  Tests which have not yet
--     concluded are indicated by inProgress(5).  The value
--     noTestsInitiated(4) indicates that no previous test
--     results are available, such as in the case when no
--     tests have been run since the last reinitialization of
--     the network management subsystem and the system has no
--     provision for non-volatile storage of test results."
--   ::= { upsTest 2 }
--
--
--------------------------------------------------------------------------
-- Note : upsTestResultsDetail MIB variable removed by Dave Cole (SEC) on 4/24/95
-- To conform with older versions of this MIB, {upsTest 3 } is reserved.
--------------------------------------------------------------------------
--------------------------------------------------------------------------
-- Note : upsTestStartTime MIB variable removed by Dave Cole (SEC) on 4/24/95
-- To conform with older versions of this MIB, {upsTest 4 } is reserved.
--------------------------------------------------------------------------
-- Control Group
--
-- upsShutdownType OBJECT-TYPE
--   SYNTAX INTEGER {
--       output(1),
--       system(2) }
--   ACCESS read-write
--   STATUS obsolete
--   DESCRIPTION
--     "Setting this object will start the output after the
--     indicated number of seconds.  Setting this object to 0
--     will cause the UPS to start the output immediately.
--     If the output is already on at the time the delay has
--     counted down, nothing will happen."
--   ::= { upsControl 1 }
--
--
-- upsShutdownAfterDelay OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-write
--   STATUS obsolete
--   DESCRIPTION
--     "Setting this object will shutdown (i.e., turn off)
--     either the UPS output or the UPS system (as determined
--     by the value of upsShhutdownType at the time of
--     shutdown) after the indicated number of seconds, or
--     less if the UPS batteries become depleted.  Setting
--     this object to 0 will cause the shutdown to occur
--     immediately.  Setting this object to -1 will abort the
--     countdown.  If the system is already in the desired
--     state at the time the countdown reaches 0, then
--     nothing will happen.  That is, there is no additional
--     action at that time if upsShutdownType = system and
--     the system is already off.  Similarly, there is no
--     additional action at that time if upsShutdownType =
--     output and the output is already off.  When read,
--     upsShutdownAfterDelay will return the number of
--     seconds remaining until shutdown, or -1 if no shutdown
--     countdown is in effect.  On some systems, if the agent
--     is restarted while a shutdown countdown is in effect,
--     the countdown may be aborted.  Sets to this object
--     override any upsShutdownAfterDelay already in effect.
--     UNITS seconds"
--   ::= { upsControl 2 }
--
--
-- upsStartupAfterDelay OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-write
--   STATUS obsolete
--   DESCRIPTION
--     "Setting this object will start the output after the
--     indicated number of seconds, includeing starting the
--     UPS, if necessary.  Setting this object to 0 will
--     cause the start to occur immediately.  Setting this
--     object to -1 will abort the countdown.  If the output
--     is already on at the time the countdown reaches 0,
--     nothing will happen.  Sets to this object
--     override the effect of any upsStartupAfterDelay
--     countdown or upsRebootDuration countdown in progress.
--     When read, upsStartupAfterDelay will return the number
--     of seconds until start, or -1 if no startup
--     countdown is in effect.  If the countdown expires
--     during a utility failure, the startup shall depend
--     upon the value of upsAutoRestart at that time.  On
--     some systems, if the agent is restarted while a
--     startup countdown is in effect, the countdown is
--     aborted.
--     UNITS seconds"
--   ::= { upsControl 3 }
--
--
-- upsRebootDuration OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-write
--   STATUS obsolete
--   DESCRIPTION
--     "Setting this object will immediately shutdown (i.e.,
--     turn off) either the UPS output or the UPS system (as
--     determined by the value of the upsShutdownType at the time
--     of shutdown)  for a period equal to the indicated
--     number of seconds, after which time the output will be
--     started, including starting the UPS, if necessary.  If
--     the number of seconds required to perform the request
--     is greater than the requested duration, then the
--     requested shutdown and startup cycle shall be
--     performed in the minimum time possible, but in no case
--     shall this require more than the requested duration
--     plus 60 seconds.  When read, upsRebootDuration shall
--     return the number of seconds remaining in the
--     countdown, or -1 if no countdown is in progress.  If
--     the startup should occur during a utility failure, the
--     startup shall depend on the value of upsAutoRestart
--     at that time.
--     UNITS seconds"
--   ::= { upsControl 4 }
--
--
-- upsAutoRestart OBJECT-TYPE
--   SYNTAX INTEGER {
--       on(1),
--       off(2) }
--   ACCESS read-write
--   STATUS obsolete
--   DESCRIPTION
--     "Setting this object to 'on' will cause the UPS system
--     to restart after a shutdown if/when utility power is present."
--   ::= { upsControl 5 }
--
--
-- upsConfig group
--------------------------------------------------------------------------
-- Note : upsConfigInputVoltage MIB variable removed by Dave Cole (SEC) on 4/24/95
-- To conform with older versions of this MIB, {upsConfig 1 } is reserved.
--------------------------------------------------------------------------
--------------------------------------------------------------------------
-- Note : upsInputFreq MIB variable removed by Dave Cole (SEC) on 4/24/95
-- To conform with older versions of this MIB, {upsConfig 2 } is reserved.
--------------------------------------------------------------------------
--------------------------------------------------------------------------
-- Note : upsConfigOutputVoltage MIB variable removed by Dave Cole (SEC) on 4/24/95
-- To conform with older versions of this MIB, {upsConfig 3 } is reserved.
--------------------------------------------------------------------------
--------------------------------------------------------------------------
-- Note : upsConfigOutputFreq MIB variable removed by Dave Cole (SEC) on 4/24/95
-- To conform with older versions of this MIB, {upsConfig 4 } is reserved.
--------------------------------------------------------------------------
--------------------------------------------------------------------------
-- Note : upsConfigOutputVA MIB variable removed by Dave Cole (SEC) on 4/24/95
-- To conform with older versions of this MIB, {upsConfig 5 } is reserved.
--------------------------------------------------------------------------
--------------------------------------------------------------------------
-- Note : upsConfigOutputPower MIB variable removed by Dave Cole (SEC) on 4/24/95
-- To conform with older versions of this MIB, {upsConfig 6 } is reserved.
--------------------------------------------------------------------------
--------------------------------------------------------------------------
-- Note : upsConfigLowBattTime MIB variable removed by Dave Cole (SEC) on 4/24/95
-- To conform with older versions of this MIB, {upsConfig 7 } is reserved.
--------------------------------------------------------------------------
--------------------------------------------------------------------------
-- Note : upsConfigAudibleStatus MIB variable removed by Dave Cole (SEC) on 4/24/95
-- To conform with older versions of this MIB, {upsConfig 8 } is reserved.
--------------------------------------------------------------------------
--------------------------------------------------------------------------
-- Note : upsConfigLowVoltageTransferPoint MIB variable removed by Dave Cole (SEC) on
-- 4/24/95.  To conform with older versions of this MIB, {upsConfig 9 } is reserved.
--------------------------------------------------------------------------
--------------------------------------------------------------------------
-- Note : upsConfigHighVoltageTransferPoint MIB variable removed by Dave Cole (SEC) on
-- 4/24/95.  To conform with older versions of this MIB, {upsConfig 10 } is reserved.
--------------------------------------------------------------------------
-- upsConfigInputVoltageHigh OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-write
--   STATUS obsolete
--   DESCRIPTION
--     "If the value of the input voltage (in Volts) exceeds this value, a
--     utilityVoltageHigh trap will be triggered."
--   ::= { upsConfig 11 }
--
--
-- upsConfigInputVoltageLow OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-write
--   STATUS obsolete
--   DESCRIPTION
--     "If the value of the input voltage (in Volts) falls below this value, a
--     utilityVoltageLow trap will be triggered."
--   ::= { upsConfig 12 }
--
--
-- upsConfigOutputPercLoadHigh OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-write
--   STATUS obsolete
--   DESCRIPTION
--     "If the value of the output percent load exceeds this value, a upsOverload trap
--     will be triggered."
--   ::= { upsConfig 13 }
--
--
-- upsConfigBatteryPercLow OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-write
--   STATUS obsolete
--   DESCRIPTION
--     "If the value of the battery percent capacity falls below this value, a lowBattery
--     trap will be triggered."
--   ::= { upsConfig 14 }
--
--
-- upsConfigBatteryTemperatureHigh OBJECT-TYPE
--   SYNTAX INTEGER
--   ACCESS read-write
--   STATUS obsolete
--   DESCRIPTION
--     "If the value of the battery temperature exceeds this value, a
--     batteryTemperatureHigh trap will be triggered."
--   ::= { upsConfig 15 }
--
--
--
-- Traps
--------------------------------------------------------------------------
-- Note : upsOnBattery trap modified by Dave Cole (SEC) on 4/24/95
-- To conform with older versions of this MIB, trap 1 is reserved.
--------------------------------------------------------------------------
--------------------------------------------------------------------------
-- Note : upsTestCompleted trap removed by Dave Cole (SEC) on 4/24/95
-- To conform with older versions of this MIB, trap 2 is reserved.
--------------------------------------------------------------------------
--------------------------------------------------------------------------
-- Note : upsAlarmEntryAdded trap removed by Dave Cole (SEC) on 4/24/95
-- To conform with older versions of this MIB, trap 3 is reserved.
--------------------------------------------------------------------------
--------------------------------------------------------------------------
-- Note : upsAlarmEntryDeleted trap removed by Dave Cole (SEC) on 4/24/95
-- To conform with older versions of this MIB, trap 4 is reserved.
--------------------------------------------------------------------------
--
-- upsOnBattery TRAP-TYPE
--   ENTERPRISE tripplite
--   VARIABLES {
--     upsIdentAttachedDevices,
--     upsEstimatedMinutesRemaining}
--   DESCRIPTION
--     "The UPS is on battery."
--  ::= 5
--
--
-- powerRestored TRAP-TYPE
--   ENTERPRISE tripplite
--   DESCRIPTION
--     "Utility power has been restored."
--  ::= 6
--
--
-- lowBattery TRAP-TYPE
--   ENTERPRISE tripplite
--   DESCRIPTION
--     "The UPS batteries are low and will soon be exhausted."
--  ::= 7
--
--
-- returnFromLowBattery TRAP-TYPE
--   ENTERPRISE tripplite
--   DESCRIPTION
--     "The UPS has returned from a low battery condition."
--  ::= 8
--
--
-- communicationEstablished TRAP-TYPE
--   ENTERPRISE tripplite
--   DESCRIPTION
--     "Communication with the UPS has been established.  This trap will be sent
--     each time there is a transition from a power off condition to a power on condition."
--  ::= 9
--
--
-- communicationLost TRAP-TYPE
--   ENTERPRISE tripplite
--   DESCRIPTION
--     "Communication with the UPS has been lost."
--  ::= 10
--
--
-- upsOverload TRAP-TYPE
--   ENTERPRISE tripplite
--   DESCRIPTION
--     "The UPS has sensed a load greater than the value of the
--     upsConfigOutputPercLoadHigh MIB variable."
--  ::= 11
--
--
-- upsDiagnosticsFailed TRAP-TYPE
--   ENTERPRISE tripplite
--   DESCRIPTION
--     "The UPS failed its self-test."
--  ::= 12
--
--
-- upsDiagnosticsPassed TRAP-TYPE
--   ENTERPRISE tripplite
--   DESCRIPTION
--     "The UPS passed its internal self-test."
--  ::= 13
--
--
-- utilityVoltageHigh TRAP-TYPE
--   ENTERPRISE tripplite
--   DESCRIPTION
--     "The UPS input voltage greater than or equal to the value of
--     the upsConfigInputVoltageHigh MIB variable."
--  ::= 14
--
--
-- utilityVoltageLow TRAP-TYPE
--   ENTERPRISE tripplite
--   DESCRIPTION
--     "The UPS input voltage is less than or equal to the value of
--     the upsConfigInputVoltageLow MIB variable."
--  ::= 15
--
--
-- utilityVoltageReturnToNormal TRAP-TYPE
--   ENTERPRISE tripplite
--   DESCRIPTION
--     "The UPS has returned from a utility voltage high or low condition."
--  ::= 16
--
--
-- batteryTemperatureHigh TRAP-TYPE
--   ENTERPRISE tripplite
--   DESCRIPTION
--     "The UPS battery temperature has exceeded the value of the
--     upsConfigBatteryTemperatureHigh MIB variable."
--  ::= 17
--
--
-- shutdownPending TRAP-TYPE
--   ENTERPRISE tripplite
--   DESCRIPTION
--     "A UPS shutdown countdown is underway."
--  ::= 18
--
--
-- upsSleeping TRAP-TYPE
--   ENTERPRISE tripplite
--   DESCRIPTION
--     "The output of the UPS has been turned off."
--  ::= 19
--
--
-- upsWokeup TRAP-TYPE
--   ENTERPRISE tripplite
--   DESCRIPTION
--     "The output of the UPS has been turned on."
--  ::= 20
--
--
-- upsBatteryNeedsReplacement TRAP-TYPE
--   ENTERPRISE tripplite
--   DESCRIPTION
--     "The UPS battery needs to be replaced."
--  ::= 21
--------------------------------------------------------------------------
-- END Delta SNMP MIB
--------------------------------------------------------------------------