summaryrefslogtreecommitdiff
path: root/MIBS/pbn/PBN-MIB
blob: df576fa45a09a6b9368a839ec5269027b91bacaa (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
3928
3929
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
3944
3945
3946
3947
3948
3949
3950
3951
3952
3953
3954
3955
3956
3957
3958
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
3981
3982
3983
3984
3985
3986
3987
3988
3989
3990
3991
3992
3993
3994
3995
3996
3997
3998
3999
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
4032
4033
4034
4035
4036
4037
4038
4039
4040
4041
4042
4043
4044
4045
4046
4047
4048
4049
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063
4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
4092
4093
4094
4095
4096
4097
4098
4099
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
4128
4129
4130
4131
4132
4133
4134
4135
4136
4137
4138
4139
4140
4141
4142
4143
4144
4145
4146
4147
4148
4149
4150
4151
4152
4153
4154
4155
4156
4157
4158
4159
4160
4161
4162
4163
4164
4165
4166
4167
4168
4169
4170
4171
4172
4173
4174
4175
4176
4177
4178
4179
4180
4181
4182
4183
4184
4185
4186
4187
4188
4189
4190
4191
4192
4193
4194
4195
4196
4197
4198
4199
4200
4201
4202
4203
4204
4205
4206
4207
4208
4209
4210
4211
4212
4213
4214
4215
4216
4217
4218
4219
4220
4221
4222
4223
4224
4225
4226
4227
4228
4229
4230
4231
4232
4233
4234
4235
4236
4237
4238
4239
4240
4241
4242
4243
4244
4245
4246
4247
4248
4249
4250
4251
4252
4253
4254
4255
4256
4257
4258
4259
4260
4261
4262
4263
4264
4265
4266
4267
4268
4269
4270
4271
4272
4273
4274
4275
4276
4277
4278
4279
4280
4281
4282
4283
4284
4285
4286
4287
4288
4289
4290
4291
4292
4293
4294
4295
4296
4297
4298
4299
4300
4301
4302
4303
4304
4305
4306
4307
4308
4309
4310
4311
4312
4313
4314
4315
4316
4317
4318
4319
4320
4321
4322
4323
4324
4325
4326
4327
4328
4329
4330
4331
4332
4333
4334
4335
4336
4337
4338
4339
4340
4341
4342
4343
4344
4345
4346
4347
4348
4349
4350
4351
4352
4353
4354
4355
4356
4357
4358
4359
4360
4361
4362
4363
4364
4365
4366
4367
4368
4369
4370
4371
4372
4373
4374
4375
4376
4377
4378
4379
4380
4381
4382
4383
4384
4385
4386
4387
4388
4389
4390
4391
4392
4393
4394
4395
4396
4397
4398
4399
4400
4401
4402
4403
4404
4405
4406
4407
4408
4409
4410
4411
4412
4413
4414
4415
4416
4417
4418
4419
4420
4421
4422
4423
4424
4425
4426
4427
4428
4429
4430
4431
4432
4433
4434
4435
4436
4437
4438
4439
4440
4441
4442
4443
4444
4445
4446
4447
4448
4449
4450
4451
4452
4453
4454
4455
4456
4457
4458
4459
4460
4461
4462
4463
4464
4465
4466
4467
4468
4469
4470
4471
4472
4473
4474
4475
4476
4477
4478
4479
4480
4481
4482
4483
4484
4485
4486
4487
4488
4489
4490
4491
4492
4493
4494
4495
4496
4497
4498
4499
4500
4501
4502
4503
4504
4505
4506
4507
4508
4509
4510
4511
4512
4513
4514
4515
4516
4517
4518
4519
4520
4521
4522
4523
4524
4525
4526
4527
4528
4529
4530
4531
4532
4533
4534
4535
4536
4537
4538
4539
4540
4541
4542
4543
4544
4545
4546
4547
4548
4549
4550
4551
4552
4553
4554
4555
4556
4557
4558
4559
4560
4561
4562
4563
4564
4565
4566
4567
4568
4569
4570
4571
4572
4573
4574
4575
4576
4577
4578
4579
4580
4581
4582
4583
4584
4585
4586
4587
4588
4589
4590
4591
4592
4593
4594
4595
4596
4597
4598
4599
4600
4601
4602
4603
4604
4605
4606
4607
4608
4609
4610
4611
4612
4613
4614
4615
4616
4617
4618
4619
4620
4621
4622
4623
4624
4625
4626
4627
4628
4629
4630
4631
4632
4633
4634
4635
4636
4637
4638
4639
4640
4641
4642
4643
4644
4645
4646
4647
4648
4649
4650
4651
4652
4653
4654
4655
4656
4657
4658
4659
4660
4661
4662
4663
4664
4665
4666
4667
4668
4669
4670
4671
4672
4673
4674
4675
4676
4677
4678
4679
4680
4681
4682
4683
4684
4685
4686
4687
4688
4689
4690
4691
4692
4693
4694
4695
4696
4697
4698
4699
4700
4701
4702
4703
4704
4705
4706
4707
4708
4709
4710
4711
4712
4713
4714
4715
4716
4717
4718
4719
4720
4721
4722
4723
4724
4725
4726
4727
4728
4729
4730
4731
4732
4733
4734
4735
4736
4737
4738
4739
4740
4741
4742
4743
4744
4745
4746
4747
4748
4749
4750
4751
4752
4753
4754
4755
4756
4757
4758
4759
4760
4761
4762
4763
4764
4765
4766
4767
4768
4769
4770
4771
4772
4773
4774
4775
4776
4777
4778
4779
4780
4781
4782
4783
4784
4785
4786
4787
4788
4789
4790
4791
4792
4793
4794
4795
4796
4797
4798
4799
4800
4801
4802
4803
4804
4805
4806
4807
4808
4809
4810
4811
4812
4813
4814
4815
4816
4817
4818
4819
4820
4821
4822
4823
4824
4825
4826
4827
4828
4829
4830
4831
4832
4833
4834
4835
4836
4837
4838
4839
4840
4841
4842
4843
4844
4845
4846
4847
4848
4849
4850
4851
4852
4853
4854
4855
4856
4857
4858
4859
4860
4861
4862
4863
4864
4865
4866
4867
4868
4869
4870
4871
4872
4873
4874
4875
4876
4877
4878
4879
4880
4881
4882
4883
4884
4885
4886
4887
4888
4889
4890
4891
4892
4893
4894
4895
4896
4897
4898
4899
4900
4901
4902
4903
4904
4905
4906
4907
4908
4909
4910
4911
4912
4913
4914
4915
4916
4917
4918
4919
4920
4921
4922
4923
4924
4925
4926
4927
4928
4929
4930
4931
4932
4933
4934
4935
4936
4937
4938
4939
4940
4941
4942
4943
4944
4945
4946
4947
4948
4949
4950
4951
4952
4953
4954
4955
4956
4957
4958
4959
4960
4961
4962
4963
4964
4965
4966
4967
4968
4969
4970
4971
4972
4973
4974
4975
4976
4977
4978
4979
4980
4981
4982
4983
4984
4985
4986
4987
4988
4989
4990
4991
4992
4993
4994
4995
4996
4997
4998
4999
5000
5001
5002
5003
5004
5005
5006
5007
5008
5009
5010
5011
5012
5013
5014
5015
5016
5017
5018
5019
5020
5021
5022
5023
5024
5025
5026
5027
5028
5029
5030
5031
5032
5033
5034
5035
5036
5037
5038
5039
5040
5041
5042
5043
5044
5045
5046
5047
5048
5049
5050
5051
5052
5053
5054
5055
5056
5057
5058
5059
5060
5061
5062
5063
5064
5065
5066
5067
5068
5069
5070
5071
5072
5073
5074
5075
5076
5077
5078
5079
5080
5081
5082
5083
5084
5085
5086
5087
5088
5089
5090
5091
5092
5093
5094
5095
5096
5097
5098
5099
5100
5101
5102
5103
5104
5105
5106
5107
5108
5109
5110
5111
5112
5113
5114
5115
5116
5117
5118
5119
5120
5121
5122
5123
5124
5125
5126
5127
5128
5129
5130
5131
5132
5133
5134
5135
5136
5137
5138
5139
5140
5141
5142
5143
5144
5145
5146
5147
5148
5149
5150
5151
5152
5153
5154
5155
5156
5157
5158
5159
5160
5161
5162
5163
5164
5165
5166
5167
5168
5169
5170
5171
5172
5173
5174
5175
5176
5177
5178
5179
5180
5181
5182
5183
5184
5185
5186
5187
5188
5189
5190
5191
5192
5193
5194
5195
5196
5197
5198
5199
5200
5201
5202
5203
5204
5205
5206
5207
5208
5209
5210
5211
5212
5213
5214
5215
5216
5217
5218
5219
5220
5221
5222
5223
5224
5225
5226
5227
5228
5229
5230
5231
5232
5233
5234
5235
5236
5237
5238
5239
5240
5241
5242
5243
5244
5245
5246
5247
5248
5249
5250
5251
5252
5253
5254
5255
5256
5257
5258
5259
5260
5261
5262
5263
5264
5265
5266
5267
5268
5269
5270
5271
5272
5273
5274
5275
5276
5277
5278
5279
5280
5281
5282
5283
5284
5285
5286
5287
5288
5289
5290
5291
5292
5293
5294
5295
5296
5297
5298
5299
5300
5301
5302
5303
5304
5305
5306
5307
5308
5309
5310
5311
5312
5313
5314
5315
5316
5317
5318
5319
5320
5321
5322
5323
5324
5325
5326
5327
5328
5329
5330
5331
5332
5333
5334
5335
5336
5337
5338
5339
5340
5341
5342
5343
5344
5345
5346
5347
5348
5349
5350
5351
5352
5353
5354
5355
5356
5357
5358
5359
5360
5361
5362
5363
5364
5365
5366
5367
5368
5369
5370
5371
5372
5373
5374
5375
5376
5377
5378
5379
5380
5381
5382
5383
5384
5385
5386
5387
5388
5389
5390
5391
5392
5393
5394
5395
5396
5397
5398
5399
5400
5401
5402
5403
5404
5405
5406
5407
5408
5409
5410
5411
5412
5413
5414
5415
5416
5417
5418
5419
5420
5421
5422
5423
5424
5425
5426
5427
5428
5429
5430
5431
5432
5433
5434
5435
5436
5437
5438
5439
5440
5441
5442
5443
5444
5445
5446
5447
5448
5449
5450
5451
5452
5453
5454
5455
5456
5457
5458
5459
5460
5461
5462
5463
5464
5465
5466
5467
5468
5469
5470
5471
5472
5473
5474
5475
5476
5477
5478
5479
5480
5481
5482
5483
5484
5485
5486
5487
5488
5489
5490
5491
5492
5493
5494
5495
5496
5497
5498
5499
5500
5501
5502
5503
5504
5505
5506
5507
5508
5509
5510
5511
5512
5513
5514
5515
5516
5517
5518
5519
5520
5521
5522
5523
5524
5525
5526
5527
5528
5529
5530
5531
5532
5533
5534
5535
5536
5537
5538
5539
5540
5541
5542
5543
5544
5545
5546
5547
5548
5549
5550
5551
5552
5553
5554
5555
5556
5557
5558
5559
5560
5561
5562
5563
5564
5565
5566
5567
5568
5569
5570
5571
5572
5573
5574
5575
5576
5577
5578
5579
5580
5581
5582
5583
5584
5585
5586
5587
5588
5589
5590
5591
5592
5593
5594
5595
5596
5597
5598
5599
5600
5601
5602
5603
5604
5605
5606
5607
5608
5609
5610
5611
5612
5613
5614
5615
5616
5617
5618
5619
5620
5621
5622
5623
5624
5625
5626
5627
5628
5629
5630
5631
5632
5633
5634
5635
5636
5637
5638
5639
5640
5641
5642
5643
5644
5645
5646
5647
5648
5649
5650
5651
5652
5653
5654
5655
5656
5657
5658
5659
5660
5661
5662
5663
5664
5665
5666
5667
5668
5669
5670
5671
5672
5673
5674
5675
5676
5677
5678
5679
5680
5681
5682
5683
5684
5685
5686
5687
5688
5689
5690
5691
5692
5693
5694
5695
5696
5697
5698
5699
5700
5701
5702
5703
5704
5705
5706
5707
5708
5709
5710
5711
5712
5713
5714
5715
5716
5717
5718
5719
5720
5721
5722
5723
5724
5725
5726
5727
5728
5729
5730
5731
5732
5733
5734
5735
5736
5737
5738
5739
5740
5741
5742
5743
5744
5745
5746
5747
5748
5749
5750
5751
5752
5753
5754
5755
5756
5757
5758
5759
5760
5761
5762
5763
5764
5765
5766
5767
5768
5769
5770
5771
5772
5773
5774
5775
5776
5777
5778
5779
5780
5781
5782
5783
5784
5785
5786
5787
5788
5789
5790
5791
5792
5793
5794
5795
5796
5797
5798
5799
5800
5801
5802
5803
5804
5805
5806
5807
5808
5809
5810
5811
5812
5813
5814
5815
5816
5817
5818
5819
5820
5821
5822
5823
5824
5825
5826
5827
5828
5829
5830
5831
5832
5833
5834
5835
5836
5837
5838
5839
5840
5841
5842
5843
5844
5845
5846
5847
5848
5849
5850
5851
5852
5853
5854
5855
5856
5857
5858
5859
5860
5861
5862
5863
5864
5865
5866
5867
5868
5869
5870
5871
5872
5873
5874
5875
5876
5877
5878
5879
5880
5881
5882
5883
5884
5885
5886
5887
5888
5889
5890
5891
5892
5893
5894
5895
5896
5897
5898
5899
5900
5901
5902
5903
5904
5905
5906
5907
5908
5909
5910
5911
5912
5913
5914
5915
5916
5917
5918
5919
5920
5921
5922
5923
5924
5925
5926
5927
5928
5929
5930
5931
5932
5933
5934
5935
5936
5937
5938
5939
5940
5941
5942
5943
5944
5945
5946
5947
5948
5949
5950
5951
5952
5953
5954
5955
5956
5957
5958
5959
5960
5961
5962
5963
5964
5965
5966
5967
5968
5969
5970
5971
5972
5973
5974
5975
5976
5977
5978
5979
5980
5981
5982
5983
5984
5985
5986
5987
5988
5989
5990
5991
5992
5993
5994
5995
5996
5997
5998
5999
6000
6001
6002
6003
6004
6005
6006
6007
6008
6009
6010
6011
6012
6013
6014
6015
6016
6017
6018
6019
6020
6021
6022
6023
6024
6025
6026
6027
6028
6029
6030
6031
6032
6033
6034
6035
6036
6037
6038
6039
6040
6041
6042
6043
6044
6045
6046
6047
6048
6049
6050
6051
6052
6053
6054
6055
6056
6057
6058
6059
6060
6061
6062
6063
6064
6065
6066
6067
6068
6069
6070
6071
6072
6073
6074
6075
6076
6077
6078
6079
6080
6081
6082
6083
6084
6085
6086
6087
6088
6089
6090
6091
6092
6093
6094
6095
6096
6097
6098
6099
6100
6101
6102
6103
6104
6105
6106
6107
6108
6109
6110
6111
6112
6113
6114
6115
6116
6117
6118
6119
6120
6121
6122
6123
6124
6125
6126
6127
6128
6129
6130
6131
6132
6133
6134
6135
6136
6137
6138
6139
6140
6141
6142
6143
6144
6145
6146
6147
6148
6149
6150
6151
6152
6153
6154
6155
6156
6157
6158
6159
6160
6161
6162
6163
6164
6165
6166
6167
6168
6169
6170
6171
6172
6173
6174
6175
6176
6177
6178
6179
6180
6181
6182
6183
6184
6185
6186
6187
6188
6189
6190
6191
6192
6193
6194
6195
6196
6197
6198
6199
6200
6201
6202
6203
6204
6205
6206
6207
6208
6209
6210
6211
6212
6213
6214
6215
6216
6217
6218
6219
6220
6221
6222
6223
6224
6225
6226
6227
6228
6229
6230
6231
6232
6233
6234
6235
6236
6237
6238
6239
6240
6241
6242
6243
6244
6245
6246
6247
6248
6249
6250
6251
6252
6253
6254
6255
6256
6257
6258
6259
6260
6261
6262
6263
6264
6265
6266
6267
6268
6269
6270
6271
6272
6273
6274
6275
6276
6277
6278
6279
6280
6281
6282
6283
6284
6285
6286
6287
6288
6289
6290
6291
6292
6293
6294
6295
6296
6297
6298
6299
6300
6301
6302
6303
6304
6305
6306
6307
6308
6309
6310
6311
6312
6313
6314
6315
6316
6317
6318
6319
6320
6321
6322
6323
6324
6325
6326
6327
6328
6329
6330
6331
6332
6333
6334
6335
6336
6337
6338
6339
6340
6341
6342
6343
6344
6345
6346
6347
6348
6349
6350
6351
6352
6353
6354
6355
6356
6357
6358
6359
6360
6361
6362
6363
6364
6365
6366
6367
6368
6369
6370
6371
6372
6373
6374
6375
6376
6377
6378
6379
6380
6381
6382
6383
6384
6385
6386
6387
6388
6389
6390
6391
6392
6393
6394
6395
6396
6397
6398
6399
6400
6401
6402
6403
6404
6405
6406
6407
6408
6409
6410
6411
6412
6413
6414
6415
6416
6417
6418
6419
6420
6421
6422
6423
6424
6425
6426
6427
6428
6429
6430
6431
6432
6433
6434
6435
6436
6437
6438
6439
6440
6441
6442
6443
6444
6445
6446
6447
6448
6449
6450
6451
6452
6453
6454
6455
6456
6457
6458
6459
6460
6461
6462
6463
6464
6465
6466
6467
6468
6469
6470
6471
6472
6473
6474
6475
6476
6477
6478
6479
6480
6481
6482
6483
6484
6485
6486
6487
6488
6489
6490
6491
6492
6493
6494
6495
6496
6497
6498
6499
6500
6501
6502
6503
6504
6505
6506
6507
6508
6509
6510
6511
6512
6513
6514
6515
6516
6517
6518
6519
6520
6521
6522
6523
6524
6525
6526
6527
6528
6529
6530
6531
6532
6533
6534
6535
6536
6537
6538
6539
6540
6541
6542
6543
6544
6545
6546
6547
6548
6549
6550
6551
6552
6553
6554
6555
6556
6557
6558
6559
6560
6561
6562
6563
6564
6565
6566
6567
6568
6569
6570
6571
6572
6573
6574
6575
6576
6577
6578
6579
6580
6581
6582
6583
6584
6585
6586
6587
6588
6589
6590
6591
6592
6593
6594
6595
6596
6597
6598
6599
6600
6601
6602
6603
6604
6605
6606
6607
6608
6609
6610
6611
6612
6613
6614
6615
6616
6617
6618
6619
6620
6621
6622
6623
6624
6625
6626
6627
6628
6629
6630
6631
6632
6633
6634
6635
6636
6637
6638
6639
6640
6641
6642
6643
6644
6645
6646
6647
6648
6649
6650
6651
6652
6653
6654
6655
6656
6657
6658
6659
6660
6661
6662
6663
6664
6665
6666
6667
6668
6669
6670
6671
6672
6673
6674
6675
6676
6677
6678
6679
6680
6681
6682
6683
6684
6685
6686
6687
6688
6689
6690
6691
6692
6693
6694
6695
6696
6697
6698
6699
6700
6701
6702
6703
6704
6705
6706
6707
6708
6709
6710
6711
6712
--
-- PBN-MIB.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 7.0  Build 220
-- Friday, May 09, 2008 at 13:45:10
--

-- **************************************************************************
-- File PBN.mib
-- 
-- 
-- Copyright (C)2007 by PBN Networks
-- 
-- 
-- MODULE-IDENTITY
-- 
-- Last Updated : 06 JULY 2007
-- 
-- OrgName
-- Pacific Broadband Networks
-- 
-- ContactInfo
-- 8-10 Keith Campbell Court, 
-- SCORESBY VIC 3179,
-- Australia
-- Telephone: +61-3-9763-1800
-- Facsimile: +61-3-9763-5522
-- e-mail nms3@pbn.com.au
-- 
-- Description
-- MIB for the PBN advance optic products
-- 
-- Version - dependencies
-- 
-- 
-- History :
--  13-Mar-08 - Added MAU module and associated traps
--                   - Additional generic types for common reference
--  06/07/2007 - Added FPCM
--  04/01/2006 - Update for OSLAM-8G for beta product release
--  12/12/2006 - Updated comments for CPON-100
--             - Updating OSLAM-8G table
--  10/11/2006 - Adding OSLAM-8G
--  31/08/2006 - Adding CPON-100
--  20/03/2006 - Update "ContactInfo"
--  30/11/2002 - Second draft
--  02/08/2002 - First draft
-- **************************************************************************

	PBN-MIB DEFINITIONS ::= BEGIN
 
		IMPORTS
			OBJECT-TYPE			
				FROM RFC-1212			
			TRAP-TYPE			
				FROM RFC-1215			
			enterprises, IpAddress, Counter, Opaque			
				FROM RFC1155-SMI			
			DisplayString			
				FROM RFC1213-MIB;
	
	
--
-- Type definitions
--
	
		TypePowerSupply ::= INTEGER
			{
			ac220V(1),
			ac60V(2)
			}

		TypeTamper ::= INTEGER
			{
			open(1),
			yes(2)
			}

		TypeYesNo ::= INTEGER
			{
			no(1),
			yes(2)
			}

		TypeOnOff ::= INTEGER
			{
			off(1),
			on(2)
			}

		TypeAGCStatus ::= INTEGER
			{
			unlock(1),
			lock(2)
			}

		TypeGainMode ::= INTEGER
			{
			auto(1),
			manual(2)
			}

	
--
-- Node definitions
--
	
		-- 1.3.6.1.4.1.11606
		pbn OBJECT IDENTIFIER ::= { enterprises 11606 }

		
-- PBN Enterprise trap
		-- 1.3.6.1.4.1.11606.0
		pbnTrap OBJECT IDENTIFIER ::= { pbn 0 }

		
-- OCM: Optical Communication Mainframe chassis
-- ============================================
-- Supported all Series 2 and Series 3 OCM
		-- 1.3.6.1.4.1.11606.1
		ocm OBJECT IDENTIFIER ::= { pbn 1 }

		
-- **************************************************************************
-- ***************** OCM - OCMF, OCMR, OCMC ******************************
-- **************************************************************************
-- **************************************************************************
-- PBNDevice : The devices managed by PBN Network Management System
		-- 1.3.6.1.4.1.11606.1.1
		pbnDevice OBJECT-TYPE
			SYNTAX INTEGER (1 | 2 | 30)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"PBN Networks Management Devices"
			::= { ocm 1 }

		
-- **************************************************************************
-- PBNDeviceAddress : The devices managed by PBN Network Management System
		-- 1.3.6.1.4.1.11606.1.2
		deviceAddress OBJECT-TYPE
			SYNTAX INTEGER (0..255)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"PBN Networks Management Device Address"
			::= { ocm 2 }

		
-- **************************************************************************
-- OCMSlot : The OCM slot of the PBN device
		-- 1.3.6.1.4.1.11606.1.3
		ocmSlot OBJECT-TYPE
			SYNTAX INTEGER (0..8)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"The OCM slot of the PBN device"
			::= { ocm 3 }

		
-- **************************************************************************
-- OCMPage : The device page
		-- 1.3.6.1.4.1.11606.1.4
		ocmPage OBJECT-TYPE
			SYNTAX INTEGER (0..7)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"The Device Page"
			::= { ocm 4 }

		
-- **************************************************************************
-- OCMParam : The OCM Parameter
		-- 1.3.6.1.4.1.11606.1.5
		ocmParam OBJECT-TYPE
			SYNTAX INTEGER (0..31)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"The Device Parameter"
			::= { ocm 5 }

		
-- **************************************************************************
-- OCMParamStatus : The OCM Param Status
		-- 1.3.6.1.4.1.11606.1.6
		ocmParamStatus OBJECT-TYPE
			SYNTAX INTEGER (0..3)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"The parameter status"
			::= { ocm 6 }

		
-- **************************************************************************
-- OCMParamString : The OCM Parameter String
		-- 1.3.6.1.4.1.11606.1.7
		ocmParamString OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"The parameter string"
			::= { ocm 7 }

		
-- **************************************************************************
-- OCMWriteParameterValue : The OCM Write Parameter Value
		-- 1.3.6.1.4.1.11606.1.8
		ocmWriteParameterValue OBJECT-TYPE
			SYNTAX INTEGER
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"The Write Parameter Value ID"
			::= { ocm 8 }

		
-- **************************************************************************
-- OCMToggleParameterValue : The OCM Toggle Parameter Value
		-- 1.3.6.1.4.1.11606.1.9
		ocmToggleParameterValue OBJECT-TYPE
			SYNTAX INTEGER
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"The Toggle Parameter Value ID"
			::= { ocm 9 }

		
-- **************************************************************************
-- ****************************** CPON-100 **********************************
-- **************************************************************************
-- **************************************************************************
-- OCMReadParameterValue : The OCM Read Parameter Value
		-- 1.3.6.1.4.1.11606.1.10
		ocmReadParameterValue OBJECT-TYPE
			SYNTAX INTEGER
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"The Toggle Parameter Value ID"
			::= { ocm 10 }

		
-- CPON-100: Customer Premises Optical Node for fast Ethernet and CATV.
-- ====================================================================
-- The unit provides future-proof high bandwidth via fibre to the home services (FTTH).
-- The integrated fibre splice organiser negates the need for extra boxes.
-- The compact design has been tailored with security and ease of installation in mind.
		-- 1.3.6.1.4.1.11606.2
		cpon100 OBJECT IDENTIFIER ::= { pbn 2 }

		
-- CPON-100 trap
		-- 1.3.6.1.4.1.11606.2.0
		cpon100Trap OBJECT IDENTIFIER ::= { cpon100 0 }

		
-- CATV power ON/OFF control:
-- (0) - Disable CATV service
-- (1) - Enable CATV service
		-- 1.3.6.1.4.1.11606.2.1
		catvCtrl OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"CATV Service Control"
			::= { cpon100 1 }

		
-- Master alarm status: Currently not used.
-- (0) - Master alarm OFF
-- (1) - Master alarm ON
		-- 1.3.6.1.4.1.11606.2.2
		masterAlarmStatus OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-only
			STATUS obsolete
			DESCRIPTION
				"Master Alarm Status"
			::= { cpon100 2 }

		
-- Contact input aka. Tamper status:
-- (0) - Contact CLOSE
-- (1) - Contact OPEN
		-- 1.3.6.1.4.1.11606.2.3
		contactInput OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Tamper Status"
			::= { cpon100 3 }

		
-- CATV optical status:
-- (0) - CATV-RX not present
-- (1) - Urgent alarm (optical high)
-- (2) - OK
-- (3) - Non-Urgent alarm (optical low)
		-- 1.3.6.1.4.1.11606.2.4
		catvStatus OBJECT-TYPE
			SYNTAX INTEGER (0..3)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"CATV Service Status"
			::= { cpon100 4 }

		
-- Sensing input:
-- (0) - OFF or CLOSE
-- (1) - ON or OPEN
		-- 1.3.6.1.4.1.11606.2.5
		sensingInput OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Sensing Input"
			::= { cpon100 5 }

		
-- Global packet size support:
-- (0) - Accept max packet size 1522 for tagged packets and 
--       1518 for untagged packets.
-- (1) - Accept packet size of up to 1536
-- (2) - Accept packet size of up to 1916
		-- 1.3.6.1.4.1.11606.2.6
		globalPktSize OBJECT-TYPE
			SYNTAX INTEGER (0..2)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Packet Size"
			::= { cpon100 6 }

		
-- Multicast storm protection:
-- (0) - "Broadcast Storm Protection" includes DA=FFFFFFFFFFFF 
--       and DA[40] = 1 packets
-- (1) - "Broadcast Storm Protection" does not include multicast packets.
--       Only DA=FFFFFFFFFFFF packets will be regulated.
		-- 1.3.6.1.4.1.11606.2.7
		globalMulticastStormProtection OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Multicast Storm Protection"
			::= { cpon100 7 }

		
-- Flow control enable/disable:
-- (0) - Will enable both TRANSMIT and RECEIVE flow control based on Auto-Negotiation result.
-- 
-- (1) - Will not enable RECEIVE flow control based regardless of strap option
--       and 
--       Will enable TRANSMIT flow control based on Auto-Negotiation result.
-- 
-- (2) - Will not enable TRANSMIT flow control based regardless of strap option
--       and
--       Will enable RECEIVE flow control based on Auto-Negotiation result.
-- 
-- (3) - Disable both TRANSMIT and RECEIVE flow control regardless of strap option.
		-- 1.3.6.1.4.1.11606.2.8
		globalFlowCtrl OBJECT-TYPE
			SYNTAX INTEGER (0..3)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Flow Control"
			::= { cpon100 8 }

		
-- Back pressure mode:
-- (0) - Collision based back pressure selected.
-- (1) - Carrier sense based back pressure selected.
		-- 1.3.6.1.4.1.11606.2.9
		globalBackPressureMode OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Back Pressure Mode"
			::= { cpon100 9 }

		
-- Priority buffer reserve:
-- (0) - No reserved buffers for high priority packets.
-- (1) - Each output queue is pre-allocated 48 buffers, 
--       used exclusively for hig priority packets. 
--       It is recommended to enable this when priority 
--       queue feature is turned on.
-- 
		-- 1.3.6.1.4.1.11606.2.10
		globalPriorityBufferReserve OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Priority Buffer Reserve"
			::= { cpon100 10 }

		
-- Priority scheme select:
-- (0) - Always deliver high priority packets first.
-- (1) - Deliver high/low packets at ration 10/1
-- (2) - Deliver high/low packets at ration 5/1
-- (3) - Deliver high/low packets at ration 2/1
		-- 1.3.6.1.4.1.11606.2.11
		globalPriorityScheme OBJECT-TYPE
			SYNTAX INTEGER (0..3)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Priority Scheme Select"
			::= { cpon100 11 }

		
-- 802.1p Based priority:
-- Used to classify priority for incoming 802.1q packets "Use priority" 
-- is compared against this value.
-- (+): classified as priority 
-- <: classified as low priority
		-- 1.3.6.1.4.1.11606.2.12
		global802dot1PBasedPriority OBJECT-TYPE
			SYNTAX INTEGER (0..7)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"802.1p Based priority"
			::= { cpon100 12 }

		
-- 802.1q VLAN enable:
-- (0) - 802.1q VLAN is disabled.
-- (1) - 802.1q VLAN mode is turned on. VLAN table needs to set 
--       up before the operation.
		-- 1.3.6.1.4.1.11606.2.13
		global802dot1qVLANEnable OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"802.1q VLAN enable"
			::= { cpon100 13 }

		
-- Null VID Replacement:
-- (0) - No replacement for null VID.
-- (1) - Replace NULL VID with port VID (12bits)
		-- 1.3.6.1.4.1.11606.2.14
		globalNullVIDReplacement OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Null VID Replacement"
			::= { cpon100 14 }

		
-- Source address MAC pause control frame:
-- 48bit MAC address
		-- 1.3.6.1.4.1.11606.2.15
		sourceMACPauseCtrl OBJECT-TYPE
			SYNTAX Opaque (SIZE (6))
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Source Address MAC Pause"
			::= { cpon100 15 }

		
-- Fast age enable:
-- (0) - Turn off fast age
-- (1) - Turn on fast age (800us)
		-- 1.3.6.1.4.1.11606.2.16
		globalFastAge OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Fast Age"
			::= { cpon100 16 }

		
-- MAC address.
		-- 1.3.6.1.4.1.11606.2.17
		cpon100MACAddr OBJECT-TYPE
			SYNTAX OCTET STRING (SIZE (0..5))
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"CPON-100 SNMP MAC Address"
			::= { cpon100 17 }

		
-- Trap severity
-- 0 - Normal
-- 1 - Non-Urgent
-- 2 - Urgent
		-- 1.3.6.1.4.1.11606.2.18
		cpon100TrapStatus OBJECT-TYPE
			SYNTAX INTEGER (0..2)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"CPON-100 Trap severity"
			::= { cpon100 18 }

		
-- Trap Message
		-- 1.3.6.1.4.1.11606.2.19
		cpon100TrapMsg OBJECT-TYPE
			SYNTAX DisplayString (SIZE (0..63))
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"CPON-100 Trap Message"
			::= { cpon100 19 }

		
-- CPON-100 VLAN Table
		-- 1.3.6.1.4.1.11606.2.21
		vlanTable OBJECT IDENTIFIER ::= { cpon100 21 }

		
-- CPON-100 VLAN1
		-- 1.3.6.1.4.1.11606.2.21.1
		vlanAddr1 OBJECT-TYPE
			SYNTAX INTEGER (0..16777215)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"CPON-100-100 VLAN1"
			::= { vlanTable 1 }

		
-- CPON-100  VLAN2
		-- 1.3.6.1.4.1.11606.2.21.2
		vlanAddr2 OBJECT-TYPE
			SYNTAX INTEGER (0..16777215)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"CPON-100 VLAN2"
			::= { vlanTable 2 }

		
-- CPON-100 VLAN3
		-- 1.3.6.1.4.1.11606.2.21.3
		vlanAddr3 OBJECT-TYPE
			SYNTAX INTEGER (0..16777215)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"CPON-100 VLAN3"
			::= { vlanTable 3 }

		
-- CPON-100 Static MAC Table
		-- 1.3.6.1.4.1.11606.2.22
		staticMACTable OBJECT IDENTIFIER ::= { cpon100 22 }

		
-- Static MAC Address entry 1:
-- When reading data from this OID
-- ===============================
-- BIT[0:47] - 48 bit MAC address
-- BIT[48:52]- Forwarding Ports. E.g.
--             "10000" - Forward to port1
--             "01000" - Forward to port2
--             "01100" - Forward to port2 and 3
-- BIT[53]   - Valid
--             (0) This entry is not valid
--             (1) This entry is valid, the lookup result will be used.
-- BIT[54]   - Override
--             (0) No override
--             (1) Override spanning tree "transmit enable = 0" 
--                 or "receive enable = 0" setting. This bit is 
--                 used for spanning tree implementation.
-- BIT[55]   - Reserve
-- BIT[56]   - Use FID
--             (0) - Use MAC only to lookup in static table
--             (1) - Use (FID+MAC) to lookup in static table
-- BIT[57:60]- Filter VLAN ID, representing on of the 16 active VLANs
-- 
-- When writing data to this OID
-- ==============================
-- BIT[0:47] - 48 bit MAC address
-- BIT[48:52]- Forwarding Ports. E.g.
--             "10000" - Forward to port1
--             "01000" - Forward to port2
--             "01100" - Forward to port2 and 3
-- BIT[53]   - Valid
--             (0) This entry is not valid
--             (1) This entry is valid, the lookup result will be used.
-- BIT[54]   - Override
--             (0) No override
--             (1) Override spanning tree "transmit enable = 0" 
--                 or "receive enable = 0" setting. This bit is 
--                 used for spanning tree implementation.
-- BIT[55]   - Use FID
--             (0) - Use MAC only to lookup in static table
--             (1) - Use (FID+MAC) to lookup in static table
-- BIT[56:59]- Filter VLAN ID, representing on of the 16 active VLANs
		-- 1.3.6.1.4.1.11606.2.22.1
		staticMAC1 OBJECT-TYPE
			SYNTAX Opaque (SIZE (8))
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Static MAC entry 1"
			::= { staticMACTable 1 }

		
-- Static MAC Address entry 2
-- When reading data from this OID
-- ===============================
-- BIT[0:47] - 48 bit MAC address
-- BIT[48:52]- Forwarding Ports. E.g.
--             "10000" - Forward to port1
--             "01000" - Forward to port2
--             "01100" - Forward to port2 and 3
-- BIT[53]   - Valid
--             (0) This entry is not valid
--             (1) This entry is valid, the lookup result will be used.
-- BIT[54]   - Override
--             (0) No override
--             (1) Override spanning tree "transmit enable = 0" 
--                 or "receive enable = 0" setting. This bit is 
--                 used for spanning tree implementation.
-- BIT[55]   - Reserve
-- BIT[56]   - Use FID
--             (0) - Use MAC only to lookup in static table
--             (1) - Use (FID+MAC) to lookup in static table
-- BIT[57:60]- Filter VLAN ID, representing on of the 16 active VLANs
-- 
-- When writing data to this OID
-- ==============================
-- BIT[0:47] - 48 bit MAC address
-- BIT[48:52]- Forwarding Ports. E.g.
--             "10000" - Forward to port1
--             "01000" - Forward to port2
--             "01100" - Forward to port2 and 3
-- BIT[53]   - Valid
--             (0) This entry is not valid
--             (1) This entry is valid, the lookup result will be used.
-- BIT[54]   - Override
--             (0) No override
--             (1) Override spanning tree "transmit enable = 0" 
--                 or "receive enable = 0" setting. This bit is 
--                 used for spanning tree implementation.
-- BIT[55]   - Use FID
--             (0) - Use MAC only to lookup in static table
--             (1) - Use (FID+MAC) to lookup in static table
-- BIT[56:59]- Filter VLAN ID, representing on of the 16 active VLANs
		-- 1.3.6.1.4.1.11606.2.22.2
		staticMAC2 OBJECT-TYPE
			SYNTAX Opaque (SIZE (8))
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Static MAC entry 2"
			::= { staticMACTable 2 }

		
-- Static MAC Address entry 3
-- When reading data from this OID
-- ===============================
-- BIT[0:47] - 48 bit MAC address
-- BIT[48:52]- Forwarding Ports. E.g.
--             "10000" - Forward to port1
--             "01000" - Forward to port2
--             "01100" - Forward to port2 and 3
-- BIT[53]   - Valid
--             (0) This entry is not valid
--             (1) This entry is valid, the lookup result will be used.
-- BIT[54]   - Override
--             (0) No override
--             (1) Override spanning tree "transmit enable = 0" 
--                 or "receive enable = 0" setting. This bit is 
--                 used for spanning tree implementation.
-- BIT[55]   - Reserve
-- BIT[56]   - Use FID
--             (0) - Use MAC only to lookup in static table
--             (1) - Use (FID+MAC) to lookup in static table
-- BIT[57:60]- Filter VLAN ID, representing on of the 16 active VLANs
-- 
-- When writing data to this OID
-- ==============================
-- BIT[0:47] - 48 bit MAC address
-- BIT[48:52]- Forwarding Ports. E.g.
--             "10000" - Forward to port1
--             "01000" - Forward to port2
--             "01100" - Forward to port2 and 3
-- BIT[53]   - Valid
--             (0) This entry is not valid
--             (1) This entry is valid, the lookup result will be used.
-- BIT[54]   - Override
--             (0) No override
--             (1) Override spanning tree "transmit enable = 0" 
--                 or "receive enable = 0" setting. This bit is 
--                 used for spanning tree implementation.
-- BIT[55]   - Use FID
--             (0) - Use MAC only to lookup in static table
--             (1) - Use (FID+MAC) to lookup in static table
-- BIT[56:59]- Filter VLAN ID, representing on of the 16 active VLANs
		-- 1.3.6.1.4.1.11606.2.22.3
		staticMAC3 OBJECT-TYPE
			SYNTAX Opaque (SIZE (8))
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Static MAC entry 3"
			::= { staticMACTable 3 }

		
-- Static MAC Address entry 4
-- When reading data from this OID
-- ===============================
-- BIT[0:47] - 48 bit MAC address
-- BIT[48:52]- Forwarding Ports. E.g.
--             "10000" - Forward to port1
--             "01000" - Forward to port2
--             "01100" - Forward to port2 and 3
-- BIT[53]   - Valid
--             (0) This entry is not valid
--             (1) This entry is valid, the lookup result will be used.
-- BIT[54]   - Override
--             (0) No override
--             (1) Override spanning tree "transmit enable = 0" 
--                 or "receive enable = 0" setting. This bit is 
--                 used for spanning tree implementation.
-- BIT[55]   - Reserve
-- BIT[56]   - Use FID
--             (0) - Use MAC only to lookup in static table
--             (1) - Use (FID+MAC) to lookup in static table
-- BIT[57:60]- Filter VLAN ID, representing on of the 16 active VLANs
-- 
-- When writing data to this OID
-- ==============================
-- BIT[0:47] - 48 bit MAC address
-- BIT[48:52]- Forwarding Ports. E.g.
--             "10000" - Forward to port1
--             "01000" - Forward to port2
--             "01100" - Forward to port2 and 3
-- BIT[53]   - Valid
--             (0) This entry is not valid
--             (1) This entry is valid, the lookup result will be used.
-- BIT[54]   - Override
--             (0) No override
--             (1) Override spanning tree "transmit enable = 0" 
--                 or "receive enable = 0" setting. This bit is 
--                 used for spanning tree implementation.
-- BIT[55]   - Use FID
--             (0) - Use MAC only to lookup in static table
--             (1) - Use (FID+MAC) to lookup in static table
-- BIT[56:59]- Filter VLAN ID, representing on of the 16 active VLANs
		-- 1.3.6.1.4.1.11606.2.22.4
		staticMAC4 OBJECT-TYPE
			SYNTAX Opaque (SIZE (8))
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Static MAC entry 4"
			::= { staticMACTable 4 }

		
-- Static MAC Address entry 5
-- When reading data from this OID
-- ===============================
-- BIT[0:47] - 48 bit MAC address
-- BIT[48:52]- Forwarding Ports. E.g.
--             "10000" - Forward to port1
--             "01000" - Forward to port2
--             "01100" - Forward to port2 and 3
-- BIT[53]   - Valid
--             (0) This entry is not valid
--             (1) This entry is valid, the lookup result will be used.
-- BIT[54]   - Override
--             (0) No override
--             (1) Override spanning tree "transmit enable = 0" 
--                 or "receive enable = 0" setting. This bit is 
--                 used for spanning tree implementation.
-- BIT[55]   - Reserve
-- BIT[56]   - Use FID
--             (0) - Use MAC only to lookup in static table
--             (1) - Use (FID+MAC) to lookup in static table
-- BIT[57:60]- Filter VLAN ID, representing on of the 16 active VLANs
-- 
-- When writing data to this OID
-- ==============================
-- BIT[0:47] - 48 bit MAC address
-- BIT[48:52]- Forwarding Ports. E.g.
--             "10000" - Forward to port1
--             "01000" - Forward to port2
--             "01100" - Forward to port2 and 3
-- BIT[53]   - Valid
--             (0) This entry is not valid
--             (1) This entry is valid, the lookup result will be used.
-- BIT[54]   - Override
--             (0) No override
--             (1) Override spanning tree "transmit enable = 0" 
--                 or "receive enable = 0" setting. This bit is 
--                 used for spanning tree implementation.
-- BIT[55]   - Use FID
--             (0) - Use MAC only to lookup in static table
--             (1) - Use (FID+MAC) to lookup in static table
-- BIT[56:59]- Filter VLAN ID, representing on of the 16 active VLANs
		-- 1.3.6.1.4.1.11606.2.22.5
		staticMAC5 OBJECT-TYPE
			SYNTAX Opaque (SIZE (8))
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Static MAC entry 5"
			::= { staticMACTable 5 }

		
-- CPON-100 Dynamic MAC Table
		-- 1.3.6.1.4.1.11606.2.23
		dynamicMACTable OBJECT IDENTIFIER ::= { cpon100 23 }

		
-- Dynamic MAC entry in the table
		-- 1.3.6.1.4.1.11606.2.23.1
		macEntryCnt OBJECT-TYPE
			SYNTAX INTEGER (0..1024)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Dynamic MAC Entry Count"
			::= { dynamicMACTable 1 }

		
-- MAC entry to read
		-- 1.3.6.1.4.1.11606.2.23.2
		macEntryID OBJECT-TYPE
			SYNTAX INTEGER (0..1024)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Dynamic MAC Entry ID"
			::= { dynamicMACTable 2 }

		
-- The dynamic MAC entry based on "macEntryID" selected
		-- 1.3.6.1.4.1.11606.2.23.3
		macEntry OBJECT-TYPE
			SYNTAX Opaque (SIZE (8))
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Dynamic MAC entry data"
			::= { dynamicMACTable 3 }

		
-- CPON-100  Customer Data Port 1 Control and Status
		-- 1.3.6.1.4.1.11606.2.24
		cpon100Port1 OBJECT IDENTIFIER ::= { cpon100 24 }

		
-- Link status:
-- (0) - Link not good
-- (1) - Link good
		-- 1.3.6.1.4.1.11606.2.24.1
		port1LinkStatus OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Link Status"
			::= { cpon100Port1 1 }

		
-- MDI-X status:
-- (0) - MDI-X or Cross Over cable plugged in
-- (1) - MDI or Straight through cable plugged
		-- 1.3.6.1.4.1.11606.2.24.2
		port1MDIXStatus OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 MID-X Status"
			::= { cpon100Port1 2 }

		
-- Port Auto-negotiation status:
-- (0) - Auto negotiation not done
-- (1) - Auto negotiation done
		-- 1.3.6.1.4.1.11606.2.24.3
		port1AutoNegotiationStatus OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Auto-Negotiation Status"
			::= { cpon100Port1 3 }

		
-- Link capability:
-- Bit0: (0) - Link partner not 10BT half-duplex capable
--       (1) - Link partner 10BT halft-duplex capable
-- Bit1: (0) - Link partner no 10BT full-duplex capable
--       (1) - Link partner 10BT full-duplex capable
-- Bit2: (0) - Link partner not 100BT half-duplex capble
--       (1) - LInk partner 100BT half-duplex capable
-- Bit3: (0) - Link partner not 100BT full-duplex capble
--       (1) - LInk partner 100BT full-duplex capable
		-- 1.3.6.1.4.1.11606.2.24.4
		port1LinkCapability OBJECT-TYPE
			SYNTAX INTEGER (0..15)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Link Capability"
			::= { cpon100Port1 4 }

		
-- Flow control capability:
-- (0) - Link partner flow control incapable
-- (1) - Link partner flow control capable
		-- 1.3.6.1.4.1.11606.2.24.5
		port1FlowCtrlCapability OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Flow Control Capability"
			::= { cpon100Port1 5 }

		
-- Far end fault status:
-- (0) - No far end fault status detected.
-- (1) - Far end fault status detected.
		-- 1.3.6.1.4.1.11606.2.24.6
		port1FarEndFaultStatus OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Far End Fault Status"
			::= { cpon100Port1 6 }

		
-- Rx Lo-priority(default) octet count including bad packets
		-- 1.3.6.1.4.1.11606.2.24.7
		port1RxLoPriorityByte OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Receive Low Priority Octet Counter"
			::= { cpon100Port1 7 }

		
-- Rx Hi-priority(default) octet count including bad packets
		-- 1.3.6.1.4.1.11606.2.24.8
		port1RxHiPriorityByte OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Receive High Priority Octet Counter"
			::= { cpon100Port1 8 }

		
-- Rx undersize packets with good CRC
		-- 1.3.6.1.4.1.11606.2.24.9
		port1UndersizePkt OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Undersize Packet Counter"
			::= { cpon100Port1 9 }

		
-- Rx packets longer than 1522 byte with either CRC errors,
-- alignment errors, or symbol errors ( depends on max packet size setting)
		-- 1.3.6.1.4.1.11606.2.24.12
		port1RxJabbers OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Receive Jabbers Counter"
			::= { cpon100Port1 12 }

		
-- Rx packet within (64, 1522) bytes with an integral number of bytes and a 
-- bad CRC (Upper limit depends on max packet size setting)
		-- 1.3.6.1.4.1.11606.2.24.14
		port1CRCError OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 CRC Error Counter"
			::= { cpon100Port1 14 }

		
-- The number of PAUSE frames received by a port. 
-- PAUSE frame is qualified with EtherType (88-08h), 
-- DA, control opcode(00-01), data length (64bytes mine), 
-- and a valid CRC
		-- 1.3.6.1.4.1.11606.2.24.17
		port1RxPausePkts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Receive Pause Packet Counter"
			::= { cpon100Port1 17 }

		
-- Rx good broadcast packets( not including errored broadcast packets 
-- or valid multicast packets).
		-- 1.3.6.1.4.1.11606.2.24.18
		port1Broadcast OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Good Broadcast Packet counter"
			::= { cpon100Port1 18 }

		
-- Rx good multicast packets (not including MAC control frames, 
-- errored multicast packets or valid broadcast packets)
		-- 1.3.6.1.4.1.11606.2.24.19
		port1RxMulticast OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Receive Good Multicast Packet Counter"
			::= { cpon100Port1 19 }

		
-- Rx good unicast packets.
		-- 1.3.6.1.4.1.11606.2.24.20
		port1RxUnicast OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Receive Unicast Counter"
			::= { cpon100Port1 20 }

		
-- Total Rx packets (bad packets included) that were 64 octets in length
		-- 1.3.6.1.4.1.11606.2.24.21
		port1Rx64Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Receive 64Octets Counter"
			::= { cpon100Port1 21 }

		
-- Total Rx packets (bad packets included) that are between 65 and 127 
-- octets in length
		-- 1.3.6.1.4.1.11606.2.24.22
		port1Rx65to127Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Receive 65 to 127 Octets Counter"
			::= { cpon100Port1 22 }

		
-- Total Rx packets (bad packets included) that are between 128 and 255 
-- octets in length
		-- 1.3.6.1.4.1.11606.2.24.23
		port1Rx128to255Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Receive 128 to 255 Octets Counter"
			::= { cpon100Port1 23 }

		
-- Total Rx packets (bad packets included) that are between 256 and 511 
-- octets in length
		-- 1.3.6.1.4.1.11606.2.24.24
		port1Rx256to511Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Receive 256 to 511 Octets Counter"
			::= { cpon100Port1 24 }

		
-- Total Rx packets (bad packets included) that are between 512 and 1023 
-- octets in length
		-- 1.3.6.1.4.1.11606.2.24.25
		port1Rx512to1023Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Receive 512 to 1023 Octets Counter"
			::= { cpon100Port1 25 }

		
-- Total Rx packets (bad packets included) that are between 1024 and 1522
-- octets in length (Upper limit depends on max packet size setting)
		-- 1.3.6.1.4.1.11606.2.24.26
		port1Rx1024to1522Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Receive 1024 to 1522 Octets Counter"
			::= { cpon100Port1 26 }

		
-- Tx Lo-priority good octet count, ncluding PAUSE packets.
		-- 1.3.6.1.4.1.11606.2.24.27
		port1TxLoPriorityByte OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Transmit Low Priority Good Octet Counter"
			::= { cpon100Port1 27 }

		
-- Tx Hi-priority good octet count, ncluding PAUSE packets.
		-- 1.3.6.1.4.1.11606.2.24.28
		port1TxHiPriorityByte OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Transmit High Priority Good Octet Counter"
			::= { cpon100Port1 28 }

		
-- The number of PAUSE frames transmitted by a port
		-- 1.3.6.1.4.1.11606.2.24.30
		port1PausePkts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Pause Packet Counter"
			::= { cpon100Port1 30 }

		
-- Tx good broadcast packets (not including errored broadcast or valid 
-- multicast packets)
		-- 1.3.6.1.4.1.11606.2.24.31
		port1TxBroadcastPkts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Transmit Good Broadcast Packet Counter"
			::= { cpon100Port1 31 }

		
-- Tx good broadcast packets (not including errored broadcast or 
-- valid multicast packets)
		-- 1.3.6.1.4.1.11606.2.24.32
		port1TxMulticastPkts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Transmit Good Multicast Packet Counter"
			::= { cpon100Port1 32 }

		
-- Tx good unicast packets.
		-- 1.3.6.1.4.1.11606.2.24.33
		port1TxUnicastPkts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Transmit Good Unicast Packet Counter"
			::= { cpon100Port1 33 }

		
-- Tx total collision, half-duplex only
		-- 1.3.6.1.4.1.11606.2.24.35
		port1TxTotalCollision OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Transmit Total Collision Packet Counter for half-duplex only"
			::= { cpon100Port1 35 }

		
-- Tx packets dropped due to lack of resources
		-- 1.3.6.1.4.1.11606.2.24.39
		port1TxDroppedPkts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Transmit Drop Packet Counter"
			::= { cpon100Port1 39 }

		
-- Rx packets dropped due to lack of resources
		-- 1.3.6.1.4.1.11606.2.24.40
		port1RxDroppedPkts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port1 Receive Drop Packet Counter"
			::= { cpon100Port1 40 }

		
-- CPON-100 Control table for Port 1
		-- 1.3.6.1.4.1.11606.2.24.45
		cpon100Port1Ctrl OBJECT IDENTIFIER ::= { cpon100Port1 45 }
-- Port1 Controls
		
-- DiffServ priority enable:
-- (0) - Disable DiffServ function. 
-- (1) - Enable DiffServ priority classification for ingress.
-- NOTE: "DiffServ", "802.1p" and port priority can be enabled at the same time
		-- 1.3.6.1.4.1.11606.2.24.45.1
		port1CtrlDiffServPriority OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 DiffServe Priority Control"
			::= { cpon100Port1Ctrl 1 }

		
-- 802.1p priority classification enable:
-- (0) - Disable 802.1p
-- (1) - Enable 802.1p priority classification for ingress
		-- 1.3.6.1.4.1.11606.2.24.45.2
		port1Ctrl802dot1pPriorityClass OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 802.1p Priority Class Enable"
			::= { cpon100Port1Ctrl 2 }

		
-- Port-based priority classification enable:
-- (0) - Ingress packets on port will be classified as low priority 
--       if "DiffSev" or "802.1p" classification is not enabled or 
--       fails to classify.
-- (1) - Ingress packets on the port will be classified as high priority
--       if "DiffServ" or "802.1p" classification is not enabled or fails
--       to classify.
		-- 1.3.6.1.4.1.11606.2.24.45.3
		port1CtrlPortBasedPriority OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Port Based Priority"
			::= { cpon100Port1Ctrl 3 }

		
-- Priority enable:
-- (0) - Single output queue on the port. There is no priority 
--       differentiation even though packets are classified into 
--       high or low priority.
-- (1) - The port output queue is split into high and low priority queues.
		-- 1.3.6.1.4.1.11606.2.24.45.4
		port1CtrlPriorityCtrl OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Priority Enable"
			::= { cpon100Port1Ctrl 4 }

		
-- Auto-Negotiation:
-- (0) - Auto-Negotiation is on
-- (1) - Disable auto-negotiation, speed and duplex are decided by bit 6 
--       and 5 of the same register.
		-- 1.3.6.1.4.1.11606.2.24.45.5
		port1CtrlAutoNegotiation OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Auto-Negotiation Enable"
			::= { cpon100Port1Ctrl 5 }

		
-- Force full-Duplex:
-- (0) - Forced half-duplex if Auto-negotation is disabled or
--       Auto-negotiation is enabled but failed
-- (1) - Forced full duplex if Auto-negotiation is disabled or
--       Auto-negotiation is enabled but failed.
		-- 1.3.6.1.4.1.11606.2.24.45.6
		port1CtrlForceFullDuplex OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Force Full-duplex"
			::= { cpon100Port1Ctrl 6 }

		
-- Broadcast storm protection enable:
-- (0) - Disable broadast storm protection
-- (1) - Enable broadcast storm protection for ingress packets
		-- 1.3.6.1.4.1.11606.2.24.45.7
		port1CtrlBroadcastStormProtection OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Broadcast Storm Protection"
			::= { cpon100Port1Ctrl 7 }

		
-- Force flow control:
-- (0) - The flow control is enabled based on Auto-Negotiation result.
--       NOTE: Setting a port for both half-duplex and forced flow 
--             control is an illegal configuration. For half-duplex 
--             enable back pressure.
-- (1) - Will always enable RX and TX flow control on the port, 
--       regardless of Auto-Negotiation result.
		-- 1.3.6.1.4.1.11606.2.24.45.8
		port1CtrlForceFlowCtrl OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Force Flow Control"
			::= { cpon100Port1Ctrl 8 }

		
-- Back pressure enable:
-- (0) - Disable ports's half-duplex back pressure
-- (1) - Enable ports's half-duplex back pressure
		-- 1.3.6.1.4.1.11606.2.24.45.9
		port1CtrlBackPressure OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Backpressure Enable"
			::= { cpon100Port1Ctrl 9 }

		
-- Transmit enable:
-- (0) - Disable packet transmission on the port.
-- (1) - Enable packet transmission on the port.
		-- 1.3.6.1.4.1.11606.2.24.45.10
		port1CtrlTxEnable OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Transmit Enable"
			::= { cpon100Port1Ctrl 10 }

		
-- Receive enable:
-- (0) - Disable packet reception on the port.
-- (1) - Enable packet reception on the port.
		-- 1.3.6.1.4.1.11606.2.24.45.11
		port1CtrlRxEnable OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Receive Enable"
			::= { cpon100Port1Ctrl 11 }

		
-- Port Power Down:
-- (0) - Normal operation
-- (1) - Power down
		-- 1.3.6.1.4.1.11606.2.24.45.12
		port1CtrlPowerDown OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Port Powerdown"
			::= { cpon100Port1Ctrl 12 }

		
-- MAC loopback test:
-- (0) - Normal operation
-- (1) - Perform MAC loopback test
		-- 1.3.6.1.4.1.11606.2.24.45.13
		port1CtrlMACLoopBackTest OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 MAC Loopback Test"
			::= { cpon100Port1Ctrl 13 }

		
-- PHY loopback test:
-- (0) - Normal operation
-- (1) - Perform PHY loopback test, i.e. loopback MAC's Tx back to Rx
		-- 1.3.6.1.4.1.11606.2.24.45.14
		port1CtrlPHYLoopbackTest OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 PHY Loopback Test"
			::= { cpon100Port1Ctrl 14 }

		
-- Remote loopback test:
-- (0) - Normal operation
-- (1) - Perform remote loopback test, i.e. loopback PHY's Tx back to Rx
		-- 1.3.6.1.4.1.11606.2.24.45.15
		port1CtrlRemoteLoopbackTest OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Remote Loopback Test"
			::= { cpon100Port1Ctrl 15 }

		
-- Tag Insertion and Tag removal:
-- (0) - Disable both tag removal and tag insertion 
-- 
-- (1) - When packets are output on the port, the switch will remove 
--       802.1q tags from packets with 802.1q tags when received. 
--       The switch will not add tags to packets already tagged. 
--       The tag inserted is the ingress ports's "port VID." 
--       and
--       Disable tag insertion.
-- 
-- (2) - Disable tag removal 
--       and
--       When packets are output on the port, the switch will add 
--       802.1q tags to packets without 802.1q tags when received. 
--       The switch will not add tags to packets already tagged. 
--       The tag inserted is the ingress port's "port VID".
-- 
-- (3) - When packets are output on the port, the switch will remove 
--       802.1q tags from packets with 802.1q tags when received. 
--       The switch will not add tags to packets already tagged. 
--       The tag inserted is the ingress ports's "port VID." 
--       and
--       When packets are output on the port, the switch will add 
--       802.1q tags to packets without 802.1q tags when received. 
--       The switch will not add tags to packets already tagged. 
--       The tag inserted is the ingress port's "port VID".
		-- 1.3.6.1.4.1.11606.2.24.45.16
		port1CtrlTagInsertionRemoval OBJECT-TYPE
			SYNTAX INTEGER (0..3)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Tag Insertion/Tag Removal"
			::= { cpon100Port1Ctrl 16 }

		
-- Port based VLAN:
-- Define the port's "Port VLAN membership." Bit 4 stands 
-- for port 5, bit 3 for port 4...bit 0 for port1. The port
-- can only communicate within the membership. A '1' includes 
-- a port in the membership, a '0' excludes a port from membership.
		-- 1.3.6.1.4.1.11606.2.24.45.17
		port1CtrlPortMembership OBJECT-TYPE
			SYNTAX INTEGER (0..31)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Port Membership"
			::= { cpon100Port1Ctrl 17 }

		
-- Ingress VLAN filtering:
-- (0) - No ingress VLAN filtering.
-- (1) - The switch will discard packets whose VID port membership  
--       in VLAN table bit[20:16] does not include the ingress port.
		-- 1.3.6.1.4.1.11606.2.24.45.18
		port1CtrlIngressVLANFiltering OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Ingress VLAN Filtering"
			::= { cpon100Port1Ctrl 18 }

		
-- Discard Non-PVID packet:
-- (0) - No packets will be discarded.
-- (1) - The switch will discard packets whose VID does not 
--       match ingress port default VID.
		-- 1.3.6.1.4.1.11606.2.24.45.19
		port1CtrlDiscardNon-PVIDPkt OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Discard Non-PVID Packet"
			::= { cpon100Port1Ctrl 19 }

		
-- Default Tag:
-- This is a 16bit data for Port's default tag, containing:
-- Bit        Description:
-- =======================
-- 0..11   -  VID
-- 12      -  CFG bit
-- 13..15  -  User priority bits
		-- 1.3.6.1.4.1.11606.2.24.45.20
		port1CtrlDefaultTag OBJECT-TYPE
			SYNTAX INTEGER (0..65536)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Default Tag"
			::= { cpon100Port1Ctrl 20 }

		
-- Force speed:
-- (0) - Forced 10BT if Auto-Negotiation is disabled
-- (1) - Forced 100BT if Auto-Negotiation is disabled
		-- 1.3.6.1.4.1.11606.2.24.45.21
		port1CtrlForceSpeed OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port1 Force Speed"
			::= { cpon100Port1Ctrl 21 }

		
-- CPON-100 Customer Data Port 2 Control and Status
		-- 1.3.6.1.4.1.11606.2.25
		cpon100Port2 OBJECT IDENTIFIER ::= { cpon100 25 }

		
-- Link status:
-- (0) - Link not good
-- (1) - Link good
		-- 1.3.6.1.4.1.11606.2.25.1
		port2LinkStatus OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Link Status"
			::= { cpon100Port2 1 }

		
-- MDI-X status:
-- (0) - MDI-X or Cross Over cable plugged in
-- (1) - MDI or Straight through cable plugged
		-- 1.3.6.1.4.1.11606.2.25.2
		port2MDIXStatus OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 MDI-X Status"
			::= { cpon100Port2 2 }

		
-- Port Auto-negotiation status:
-- (0) - Auto negotiation not done
-- (1) - Auto negotiation done
		-- 1.3.6.1.4.1.11606.2.25.3
		port2AutoNegotiationStatus OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Auto-Negotiation Status"
			::= { cpon100Port2 3 }

		
-- Link capability:
-- Bit0: (0) - Link partner not 10BT half-duplex capable
--       (1) - Link partner 10BT halft-duplex capable
-- Bit1: (0) - Link partner no 10BT full-duplex capable
--       (1) - Link partner 10BT full-duplex capable
-- Bit2: (0) - Link partner not 100BT half-duplex capble
--       (1) - LInk partner 100BT half-duplex capable
-- Bit3: (0) - Link partner not 100BT full-duplex capble
--       (1) - LInk partner 100BT full-duplex capable
		-- 1.3.6.1.4.1.11606.2.25.4
		port2LinkCapability OBJECT-TYPE
			SYNTAX INTEGER (0..15)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Link Capability"
			::= { cpon100Port2 4 }

		
-- Flow control capability:
-- (0) - Link partner flow control incapable
-- (1) - Link partner flow control capable
		-- 1.3.6.1.4.1.11606.2.25.5
		port2FlowCtrlCapability OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Flow Control Capability"
			::= { cpon100Port2 5 }

		
-- Far end fault status:
-- (0) - No far end fault status detected.
-- (1) - Far end fault status detected.
		-- 1.3.6.1.4.1.11606.2.25.6
		port2FarEndFaultStatus OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Far End Fault Status"
			::= { cpon100Port2 6 }

		
-- Rx Lo-priority(default) octet count including bad packets
		-- 1.3.6.1.4.1.11606.2.25.7
		port2RxLoPriorityByte OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Receive Low Priority Octet Counter"
			::= { cpon100Port2 7 }

		
-- Rx Hi-priority(default) octet count including bad packets
		-- 1.3.6.1.4.1.11606.2.25.8
		port2RxHiPriorityByte OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Receive High Priority Octet Counter"
			::= { cpon100Port2 8 }

		
-- Rx undersize packets with good CRC
		-- 1.3.6.1.4.1.11606.2.25.9
		port2UndersizePkt OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Undersize Packet Counter"
			::= { cpon100Port2 9 }

		
-- Rx packets longer than 1522 byte with either CRC errors,
-- alignment errors, or symbol errors ( depends on max packet size setting)
		-- 1.3.6.1.4.1.11606.2.25.12
		port2RxJabbers OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Receive Jabbers Counter"
			::= { cpon100Port2 12 }

		
-- Rx packet within (64, 1522) bytes with an integral number of bytes and a 
-- bad CRC (Upper limit depends on max packet size setting)
		-- 1.3.6.1.4.1.11606.2.25.14
		port2CRCError OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 CRC Error Counter"
			::= { cpon100Port2 14 }

		
-- The number of PAUSE frames received by a port. 
-- PAUSE frame is qualified with EtherType (88-08h), 
-- DA, control opcode(00-01), data length (64bytes mine), 
-- and a valid CRC
		-- 1.3.6.1.4.1.11606.2.25.17
		port2RxPausePkts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Receive Pause Packet Counter"
			::= { cpon100Port2 17 }

		
-- Rx good broadcast packets( not including errored broadcast packets 
-- or valid multicast packets).
		-- 1.3.6.1.4.1.11606.2.25.18
		port2Broadcast OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Broadcast Good Packet Counter"
			::= { cpon100Port2 18 }

		
-- Rx good multicast packets (not including MAC control frames, 
-- errored multicast packets or valid broadcast packets)
		-- 1.3.6.1.4.1.11606.2.25.19
		port2RxMulticast OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Receive Multicast Good Packet Counter"
			::= { cpon100Port2 19 }

		
-- Rx good unicast packets.
		-- 1.3.6.1.4.1.11606.2.25.20
		port2RxUnicast OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Receive Unicast Counter"
			::= { cpon100Port2 20 }

		
-- Total Rx packets (bad packets included) that were 64 octets in length
		-- 1.3.6.1.4.1.11606.2.25.21
		port2Rx64Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Receive 64 Octets Counter"
			::= { cpon100Port2 21 }

		
-- Total Rx packets (bad packets included) that are between 65 and 127 
-- octets in length
		-- 1.3.6.1.4.1.11606.2.25.22
		port2Rx65to127Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Receive 65 to 127 Octets Counter"
			::= { cpon100Port2 22 }

		
-- Total Rx packets (bad packets included) that are between 128 and 255 
-- octets in length
		-- 1.3.6.1.4.1.11606.2.25.23
		port2Rx128to255Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Receive 128 to 255 Octets Counter"
			::= { cpon100Port2 23 }

		
-- Total Rx packets (bad packets included) that are between 256 and 511 
-- octets in length
		-- 1.3.6.1.4.1.11606.2.25.24
		port2Rx256to511Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Receive 256 to 511 Octets Counter"
			::= { cpon100Port2 24 }

		
-- Total Rx packets (bad packets included) that are between 512 and 1023 
-- octets in length
		-- 1.3.6.1.4.1.11606.2.25.25
		port2Rx512to1023Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Receive 512 to 1023 Octets Counter"
			::= { cpon100Port2 25 }

		
-- Total Rx packets (bad packets included) that are between 1024 and 1522
-- octets in length (Upper limit depends on max packet size setting)
		-- 1.3.6.1.4.1.11606.2.25.26
		port2Rx1024to1522Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Receive 1024 to 1522 Octets Counter"
			::= { cpon100Port2 26 }

		
-- Tx Lo-priority good octet count, ncluding PAUSE packets.
		-- 1.3.6.1.4.1.11606.2.25.27
		port2TxLoPriorityByte OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Transmit Low Priority Packet Counter"
			::= { cpon100Port2 27 }

		
-- Tx Hi-priority good octet count, ncluding PAUSE packets.
		-- 1.3.6.1.4.1.11606.2.25.28
		port2TxHiPriorityByte OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Transmit High Priority Packet Counter"
			::= { cpon100Port2 28 }

		
-- The number of PAUSE frames transmitted by a port
		-- 1.3.6.1.4.1.11606.2.25.30
		port2PausePkts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Pause Packet Counter"
			::= { cpon100Port2 30 }

		
-- Tx good broadcast packets (not including errored broadcast or valid 
-- multicast packets)
		-- 1.3.6.1.4.1.11606.2.25.31
		port2TxBroadcastPkts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Transmit Broadcast Packet Counter"
			::= { cpon100Port2 31 }

		
-- Tx good broadcast packets (not including errored broadcast or 
-- valid multicast packets)
		-- 1.3.6.1.4.1.11606.2.25.32
		port2TxMulticastPkts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Transmit Multicast Packet Counter"
			::= { cpon100Port2 32 }

		
-- Tx good unicast packets.
		-- 1.3.6.1.4.1.11606.2.25.33
		port2TxUnicastPkts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Transmit Unicast Packet Counter"
			::= { cpon100Port2 33 }

		
-- Tx total collision, half-duplex only
		-- 1.3.6.1.4.1.11606.2.25.35
		port2TxTotalCollision OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Transmit Total Collision Packet Counter"
			::= { cpon100Port2 35 }

		
-- Tx packets dropped due to lack of resources
		-- 1.3.6.1.4.1.11606.2.25.39
		port2TxDroppedPkts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Transmit Dropped Packet Counter"
			::= { cpon100Port2 39 }

		
-- Rx packets dropped due to lack of resources
		-- 1.3.6.1.4.1.11606.2.25.40
		port2RxDroppedPkts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Port2 Receive Dropped Packet Counter"
			::= { cpon100Port2 40 }

		
-- CPON-100 Control table for Port 2
		-- 1.3.6.1.4.1.11606.2.25.45
		port2Ctrl OBJECT IDENTIFIER ::= { cpon100Port2 45 }
-- Port2 Controls
		
-- DiffServ priority enable:
-- (0) - Disable DiffServ function. 
-- (1) - Enable DiffServ priority classification for ingress.
-- NOTE: "DiffServ", "802.1p" and port priority can be enabled at the same time
		-- 1.3.6.1.4.1.11606.2.25.45.1
		port2CtrlDiffServPriority OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 DiffServe Priority Control"
			::= { port2Ctrl 1 }

		
-- 802.1p priority classification enable:
-- (0) - Disable 802.1p
-- (1) - Enable 802.1p priority classification for ingress
		-- 1.3.6.1.4.1.11606.2.25.45.2
		port2Ctrl802dot1pPriorityClass OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 802.1p Priority Class Enable"
			::= { port2Ctrl 2 }

		
-- Port-based priority classification enable:
-- (0) - Ingress packets on port will be classified as low priority 
--       if "DiffSev" or "802.1p" classification is not enabled or 
--       fails to classify.
-- (1) - Ingress packets on the port will be classified as high priority
--       if "DiffServ" or "802.1p" classification is not enabled or fails
--       to classify.
		-- 1.3.6.1.4.1.11606.2.25.45.3
		port2CtrlPortBasedPriority OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 802.1p Priority Class Enable"
			::= { port2Ctrl 3 }

		
-- Priority enable:
-- (0) - Single output queue on the port. There is no priority 
--       differentiation even though packets are classified into 
--       high or low priority.
-- (1) - The port output queue is split into high and low priority queues.
		-- 1.3.6.1.4.1.11606.2.25.45.4
		port2CtrlPriorityCtrl OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 Priority Enable"
			::= { port2Ctrl 4 }

		
-- Auto-Negotiation:
-- (0) - Auto-Negotiation is on
-- (1) - Disable auto-negotiation, speed and duplex are decided by bit 6 
--       and 5 of the same register.
		-- 1.3.6.1.4.1.11606.2.25.45.5
		port2CtrlAutoNegotiation OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 Auto-Negotiation Enable"
			::= { port2Ctrl 5 }

		
-- Forced full-Duplex:
-- (0) - Forced half-duplex if Auto-negotation is disabled or
--       Auto-negotiation is enabled but failed
-- (1) - Forced full duplex if Auto-negotiation is disabled or
--       Auto-negotiation is enabled but failed.
		-- 1.3.6.1.4.1.11606.2.25.45.6
		port2CtrlForcedFullDuplex OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 Force Full-duplex"
			::= { port2Ctrl 6 }

		
-- Broadcast storm protection enable:
-- (0) - Disable broadast storm protection
-- (1) - Enable broadcast storm protection for ingress packets
		-- 1.3.6.1.4.1.11606.2.25.45.7
		port2CtrlBroadcastStormProtection OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 Broadcast Storm Protection Enable"
			::= { port2Ctrl 7 }

		
-- Force flow control:
-- (0) - The flow control is enabled based on Auto-Negotiation result.
--       NOTE: Setting a port for both half-duplex and forced flow 
--             control is an illegal configuration. For half-duplex 
--             enable back pressure.
-- (1) - Will always enable RX and TX flow control on the port, 
--       regardless of Auto-Negotiation result.
		-- 1.3.6.1.4.1.11606.2.25.45.8
		port2CtrlForceFlowCtrl OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 Force Flow Control"
			::= { port2Ctrl 8 }

		
-- Back pressure enable:
-- (0) - Disable ports's half-duplex back pressure
-- (1) - Enable ports's half-duplex back pressure
		-- 1.3.6.1.4.1.11606.2.25.45.9
		port2CtrlBackPressure OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 Back Pressure Enable"
			::= { port2Ctrl 9 }

		
-- Transmit enable:
-- (0) - Disable packet transmission on the port.
-- (1) - Enable packet transmission on the port.
		-- 1.3.6.1.4.1.11606.2.25.45.10
		port2CtrlTxEnable OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 Transmit Enable"
			::= { port2Ctrl 10 }

		
-- Receive enable:
-- (0) - Disable packet reception on the port.
-- (1) - Enable packet reception on the port.
		-- 1.3.6.1.4.1.11606.2.25.45.11
		port2CtrlRxEnable OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 Receive Enable"
			::= { port2Ctrl 11 }

		
-- Port Power Down:
-- (0) - Normal operation
-- (1) - Power down
		-- 1.3.6.1.4.1.11606.2.25.45.12
		port2CtrlPowerDown OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 Powerdown"
			::= { port2Ctrl 12 }

		
-- MAC loopback test:
-- (0) - Normal operation
-- (1) - Perform MAC loopback test
		-- 1.3.6.1.4.1.11606.2.25.45.13
		port2CtrlMACLoopBackTest OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 MAC Loopback Test"
			::= { port2Ctrl 13 }

		
-- PHY loopback test:
-- (0) - Normal operation
-- (1) - Perform PHY loopback test, i.e. loopback MAC's Tx back to Rx
		-- 1.3.6.1.4.1.11606.2.25.45.14
		port2CtrlPHYLoopbackTest OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 PHY Loopback Test"
			::= { port2Ctrl 14 }

		
-- Remote loopback test:
-- (0) - Normal operation
-- (1) - Perform remote loopback test, i.e. loopback PHY's Tx back to Rx
		-- 1.3.6.1.4.1.11606.2.25.45.15
		port2CtrlRemoteLoopbackTest OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 Remote Loopback Test"
			::= { port2Ctrl 15 }

		
-- Tag Insertion and Tag removal:
-- (0) - Disable both tag removal and tag insertion 
-- 
-- (1) - When packets are output on the port, the switch will remove 
--       802.1q tags from packets with 802.1q tags when received. 
--       The switch will not add tags to packets already tagged. 
--       The tag inserted is the ingress ports's "port VID." 
--       and
--       Disable tag insertion.
-- 
-- (2) - Disable tag removal 
--       and
--       When packets are output on the port, the switch will add 
--       802.1q tags to packets without 802.1q tags when received. 
--       The switch will not add tags to packets already tagged. 
--       The tag inserted is the ingress port's "port VID".
-- 
-- (3) - When packets are output on the port, the switch will remove 
--       802.1q tags from packets with 802.1q tags when received. 
--       The switch will not add tags to packets already tagged. 
--       The tag inserted is the ingress ports's "port VID." 
--       and
--       When packets are output on the port, the switch will add 
--       802.1q tags to packets without 802.1q tags when received. 
--       The switch will not add tags to packets already tagged. 
--       The tag inserted is the ingress port's "port VID".
		-- 1.3.6.1.4.1.11606.2.25.45.16
		port2CtrlTagInsertionRemoval OBJECT-TYPE
			SYNTAX INTEGER (0..3)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 Tag Insertion/Tag Removal"
			::= { port2Ctrl 16 }

		
-- Port based VLAN:
-- Define the port's "Port VLAN membership." Bit 4 stands 
-- for port 5, bit 3 for port 4...bit 0 for port1. The port
-- can only communicate within the membership. A '1' includes 
-- a port in the membership, a '0' excludes a port from membership.
		-- 1.3.6.1.4.1.11606.2.25.45.17
		port2CtrlPortMembership OBJECT-TYPE
			SYNTAX INTEGER (0..31)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 Port Membership"
			::= { port2Ctrl 17 }

		
-- Ingress VLAN filtering:
-- (0) - No ingress VLAN filtering.
-- (1) - The switch will discard packets whose VID port membership 
--       in VLAN table bit
		-- 1.3.6.1.4.1.11606.2.25.45.18
		port2CtrlIngressVLANFiltering OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 Ingress VLAN Filtering"
			::= { port2Ctrl 18 }

		
-- Discard Non-PVID packet:
-- (0) - No packets will be discarded.
-- (1) - The switch will discard packets whose VID does not 
--       match ingress port default VID.
		-- 1.3.6.1.4.1.11606.2.25.45.19
		port2CtrlDiscardNon-PVIDPkt OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 Discard Non-PVID Packet"
			::= { port2Ctrl 19 }

		
-- Default Tag:
-- This is a 16bit data for Port's default tag, containging:
-- Bit        Description:
-- =======================
-- 0..11   -  VID
-- 12      -  CFG bit
-- 13..15  -  User priority bits
		-- 1.3.6.1.4.1.11606.2.25.45.20
		port2CtrlDefaultTag OBJECT-TYPE
			SYNTAX INTEGER (0..65536)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 Default Tag"
			::= { port2Ctrl 20 }

		
-- Forced speed:
-- (0) - Forced 10BT if Auto-Negotiation is disabled
-- (1) - Forced 100BT if Auto-Negotiation is disabled
		-- 1.3.6.1.4.1.11606.2.25.45.21
		port2CtrlForceSpeed OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port2 Force Speed"
			::= { port2Ctrl 21 }

		
-- CPON-100 Uplink (Optical) port
		-- 1.3.6.1.4.1.11606.2.26
		cpon100PriUplink OBJECT IDENTIFIER ::= { cpon100 26 }

		
-- Primary uplink Link status
-- (0) - Link failed
-- (1) - Link good
		-- 1.3.6.1.4.1.11606.2.26.1
		priUplinkLinkStatus OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Uplink Link Status"
			::= { cpon100PriUplink 1 }

		
		-- 1.3.6.1.4.1.11606.2.26.45
		priUplinkPortCtrl OBJECT IDENTIFIER ::= { cpon100PriUplink 45 }
-- CPON-100 Uplink Port Controls
		
-- Primary uplink Link Remote loopback test
-- (0) - Normal operation
-- (1) - Perform loopback test
		-- 1.3.6.1.4.1.11606.2.26.45.15
		priUplinkLinkRemoteLoopbackTest OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Primary uplink Link Remote loopback test"
			::= { priUplinkPortCtrl 15 }

		
-- Transmit low priority rate control:
-- ===================================
-- A 12-bit field to determine how many "32Kbps" low priority blocks 
-- can be transmitted (in a unit of 4K bytes in a one second period)
-- 
		-- 1.3.6.1.4.1.11606.2.26.45.22
		priUplinkTxLoPriorityRateCtrl OBJECT-TYPE
			SYNTAX INTEGER (0..4095)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Primary Uplink Transmit Low Priority Rate Control"
			::= { priUplinkPortCtrl 22 }

		
-- Receive low priority rate control:
-- ===================================
-- A 12-bit field to determine how many "32Kbps" low priority blocks 
-- can be received (in a unit of 4K bytes in a one second period)
-- 
		-- 1.3.6.1.4.1.11606.2.26.45.23
		priUplinkRxLoPriorityRateCtrl OBJECT-TYPE
			SYNTAX INTEGER (0..4095)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Primary Uplink Receive Low Priority Rate Control"
			::= { priUplinkPortCtrl 23 }

		
-- Primary uplink port Transmit Differential Priority Rate Control
-- (0) - Will do transmit rate control on any packets. The rate 
--       counters defined in low priority will be used.
-- (1) - Will do transmit rate control on both high and low priority 
--       packets based on the rate counters defined by the high and 
--       low priority packets respectively.
		-- 1.3.6.1.4.1.11606.2.26.45.24
		priUplinkTxDiffPriorityRateCtrl OBJECT-TYPE
			SYNTAX INTEGER (0..1)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Primary Uplink Transmit Differential Priority Rate Control"
			::= { priUplinkPortCtrl 24 }

		
-- NOT RELEASE
		-- 1.3.6.1.4.1.11606.3
		odnrt100 OBJECT IDENTIFIER ::= { pbn 3 }

		
-- OSLAM-8G: Optical Subscriber Line Access Multiplexer
-- ====================================================
-- The new and advanced OSLAM-8G fibre optic access multiplexer provides 
-- the basic building block for highly scalable fibre-to-the-home (FTTH) 
-- and fibre-to-the-block (FTTB) applications. With 80 available line ports
-- per OCMR chassis the network costs involved are greatly reduced.
		-- 1.3.6.1.4.1.11606.4
		oslam8g OBJECT IDENTIFIER ::= { pbn 4 }

		
-- OSLAM-8G Global Controls and Status
		-- 1.3.6.1.4.1.11606.4.1
		oslam8g-Global OBJECT IDENTIFIER ::= { oslam8g 1 }

		
-- OSLAM-8G Global Control
		-- 1.3.6.1.4.1.11606.4.1.1
		oslam8g-globalCtrl OBJECT IDENTIFIER ::= { oslam8g-Global 1 }

		
		-- 1.3.6.1.4.1.11606.4.1.1.1
		oslam8gSrcMACAddr OBJECT-TYPE
			SYNTAX Opaque (SIZE (6))
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Source MAC address
				===========================
				48bit Source address MAC address for pause control frame.
				
				NOTE: First bit of 2nd octet is as followed:
				
				This bit used to have all ports transmit the same or different
				source addresses in full-duplex Pause frames.
				
				0 - All ports transmit the same Static Address (SA)
				1 - Each port uses a different SA where bits 4:47 of 
				    the 'sourceMACAddress' are the same, but bits 3:0 are the
				    port number (Port 0 = 0, Port1 = 1, Port 2 = 2, etc.)"
			::= { oslam8g-globalCtrl 1 }

		
		-- 1.3.6.1.4.1.11606.4.1.1.2
		oslam8gSchedulingMode OBJECT-TYPE
			SYNTAX INTEGER
				{
				useFairQueuingScheme(1),
				useStrictPriorityScheme(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Scheduling Mode
				=========================
				1 - Use an 8,4,2,1 weighted fair queuing scheme
				2 - Us a strict priority scheme"
			::= { oslam8g-globalCtrl 2 }

		
		-- 1.3.6.1.4.1.11606.4.1.1.3
		oslam8gMaxFrameSize OBJECT-TYPE
			SYNTAX INTEGER
				{
				sizeMax1522Octets(1),
				sizeMax1632Octets(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Maximum Frame Size allowed.
				===========================
				The Ingress block discards all frames less than 64 bytes in size.
				It also discards all frames greater than a certain size 
				(regardless of whether or not the frame is iEEE802.3ac tagged)
				as follows:
				
				1 - Max size is 1522 for IEEE tagged frames, 1518 for untagged frames.
				2 - Max size is 1632"
			::= { oslam8g-globalCtrl 3 }

		
-- 
-- 
		-- 1.3.6.1.4.1.11606.4.1.1.4
		oslam8gCoreTag OBJECT-TYPE
			SYNTAX INTEGER (0..65535)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Core Tag Type
				======================
				Core Tag Ether Type. This EtherType is added to frames that egress the
				switch as Double Tagged frames. It is also the EtherType expected during
				Ingress to determine if a frame is Tagged or not on ports configured in
				oslam8gPortEgressMode as follows:
				
				For Ingress:
				===========
				oslam8gUseCoreTag= 1, oslam8gDoubleTag = 1, TagType = 0x8100
				oslam8gUseCoreTag= 1, oslam8gDoubleTag = 2, TagType = 0x8100
				oslam8gUseCoreTag= 2, oslam8gDoubleTag = 1, TagType = oslam8gCoreTagType
				oslam8gUseCoreTag= 2, oslam8gDoubleTag = 2, 1st TagType = oslam8gCoreTagType then 
				                                2nd TagType in the frame = 0x8100
				
				
				For Egress:
				===========
				Normal Add a Tag (standard IEEE rule) Added Tag Type = 0x8100
				Always Add a Tag (Egress DoubleTag)   Added Tag Type = oslam8gCoreTagType"
			::= { oslam8g-globalCtrl 4 }

		
-- 
-- 
		-- 1.3.6.1.4.1.11606.4.1.1.5
		oslam8gUseDoubleTagData OBJECT-TYPE
			SYNTAX INTEGER
				{
				ignoreRemovedTagData(1),
				useRemovedTagData(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Use Double Tag Data
				============================
				Used to determine if Double Tag data is removed from a Double Tag 
				frame is used or ignored when making switching decisions on the frame.
				
				1 - Ignore removed Tag data
				2 - Use removed Tag data
				
				This OID have not effect if hte port's oslam8gPortDoubleTag is set to 1"
			::= { oslam8g-globalCtrl 5 }

		
-- OSLAM-8G Global Status
		-- 1.3.6.1.4.1.11606.4.1.2
		oslam8g-globalStatus OBJECT IDENTIFIER ::= { oslam8g-Global 2 }

		
		-- 1.3.6.1.4.1.11606.4.1.2.1
		oslam8gSerialNumber OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Serial Number"
			::= { oslam8g-globalStatus 1 }

		
		-- 1.3.6.1.4.1.11606.4.1.2.2
		oslam8gMACAddress OBJECT-TYPE
			SYNTAX OCTET STRING (SIZE (12))
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G SNMP MAC Address"
			::= { oslam8g-globalStatus 2 }

		
		-- 1.3.6.1.4.1.11606.4.1.2.3
		oslam8gDiagnosticMsg OBJECT-TYPE
			SYNTAX DisplayString (SIZE (0..63))
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Diagnostic Message"
			::= { oslam8g-globalStatus 3 }

		
-- 802.1Q VLAN Table
		-- 1.3.6.1.4.1.11606.4.1.3
		oslam8g-VTU OBJECT IDENTIFIER ::= { oslam8g-Global 3 }

		
		-- 1.3.6.1.4.1.11606.4.1.3.1
		vtuOperation OBJECT-TYPE
			SYNTAX INTEGER
				{
				flushAllEntries(1),
				noOperation(2),
				loadOrPurgeEntry(3),
				getNext(4),
				getClearViolation(7)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"VLAN Table Unit Table Operation
				===============================
				Support the following VTU operation.
				0, 2 - No Operation
				1    - Flush All Entries
				3    - Load(1) or Purge(2) an Entry
				4    - Get Next(3)
				5,6  - Reserve
				7    - Get/Clear Violation Data
				
				NOTE:
				(1) - An Entry is Loaded when the 'vtuValid' is set to a one. 
				      Load is the only 'vtuOperation' that uses the 'vtuDBNum' field 
				      and it uses it as data to be loaded along with the desired 'vtuVID'.
				(2) - An Entry is Purged when the 'vtuValid' is cleared to a zero.
				(3) - A Get Next operation finds the next higher 'vtuVID' curretnly in 
				      the database. The vtuVID value is used as the VID to start from.
				      To find the lowest VID set the vtuVID field to ones. 
				      When the operation is done the vtuVID field contains the next 
				      higher VID currently active in the database. To find the next
				      VID simply issue the Get Next opcode again. If the vtuVID field
				      is returned set to a one's with the vtuValid cleared to zero, 
				      no higher VID's were found. To Search for a particular VID, 
				      perform a Get Next operation using a vtuVID field with a value 
				      one less than the one being searched for."
			::= { oslam8g-VTU 1 }

		
		-- 1.3.6.1.4.1.11606.4.1.3.2
		vtuDBNum OBJECT-TYPE
			SYNTAX INTEGER (0..255)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"VTU MAC Address Database Number
				===============================
				On all vtuOperation except for Get Violation Data, this field is used to 
				separate MAC address dtabases by a frame's VID. If multiple address databases
				are not being used, theses bits must remain zero. If multiple addresss are not
				being used, theses bits must remain zero. If multiple address databases are 
				being used, these bits are used to get the desired database number that is 
				associated with VID value on Load operations (or used to read the currently
				assigned vtuDBNum on Get Next operations)."
			::= { oslam8g-VTU 2 }

		
		-- 1.3.6.1.4.1.11606.4.1.3.3
		vtuMemberViolation OBJECT-TYPE
			SYNTAX INTEGER
				{
				noViolation(1),
				violation(2)
				}
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"VTU Member Violation
				==================
				Source Member Violation. On Get/Clear Violation Data vtuOperation,
				this value is returned set to a two(2) if the Violation being serviced 
				is due to an 802.1Q Member Violation. A member Violation occurs 
				when an 802.1Q enabled ingress port accesses the VTU with a VID 
				that is cotnained in the VTU but whose Mebership list does not 
				include this Ingress port. 
				Only the first vtuFullViolation, vtuMemberViolation, vtuMissViolation 
				is saved per port until cleared."
			::= { oslam8g-VTU 3 }

		
		-- 1.3.6.1.4.1.11606.4.1.3.4
		vtuMissViolation OBJECT-TYPE
			SYNTAX INTEGER
				{
				noViolation(1),
				violation(2)
				}
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"VTU Miss Violation
				==================
				On Get/Clear Violation operation this value is set to a two(2) if the 
				Violation being serviced is due to 802.1Q Miss Violation. A Miss 
				Violation occurs when an 802.1Q enabled Ingress port accesses the
				VTU with a VID that is contained in the VTU.
				
				Only the first atuFullViolation, atuMemberViolation, atuMissViolation 
				is saved per port until cleared."
			::= { oslam8g-VTU 4 }

		
		-- 1.3.6.1.4.1.11606.4.1.3.5
		vtuValid OBJECT-TYPE
			SYNTAX INTEGER
				{
				invalidVIDOrEndOflist(1),
				validVID(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"VTU Entry Valid status.
				=======================
				At the end of Get/Next operations
				1 - If VID is all ones, it indicates the end of the VID list was reached
				    with no new valid entries.
				2 - Indicates the VID value below is valid.
				
				NOTE: On Load or Purge operations, this bit indicates the desired operation 
				      of a Load (when set to a one) or a Purge (when cleared to a zero)."
			::= { oslam8g-VTU 5 }

		
-- 
-- 
		-- 1.3.6.1.4.1.11606.4.1.3.6
		vtuVID OBJECT-TYPE
			SYNTAX INTEGER (0..4095)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"VLAN Identifier
				===============
				This VID is used in all the vtuOperation commands (except Get/Clear
				Violation Data) and it is the VID that is associated with the vtuData
				or the vtuVID that caused the VTU Violation.
				
				Theses indicate the VID number that is associated with the MemberTag
				in the vtuData, 802.1s PortState, Priority and its override."
			::= { oslam8g-VTU 6 }

		
		-- 1.3.6.1.4.1.11606.4.1.3.7
		vtuData OBJECT-TYPE
			SYNTAX Opaque (SIZE (6))
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"VLAN table data
				Entry Format as follow:
				======================
				
				BYTE#:      5      4      3      2      1      0
				Frame:   [0:P10][P9:P8][P7:P6][P5:P4][P3:P2][P1:P0]
				
				Px:       Port control
				          Size: 4bits total
				          Format: [PortState][PortMemberTag]
				
				          PortState: The upper two bits of each port's VTU data is called 802.1s PortState.
				                     These bits are used to support 802.1s per VLAN spanning tree as follows:
				                     00 - 802.1s Disabled. User non-VLAN Port states (in Port control 'portState')
				                     01 - Blocking/Listening Port State for this port for frames with this VID
				                     10 - Learning Port State for this port for frames with this VID
				                     11 - Forwarding Port State for this port for frames with this VID
				               NOTE: These 802.1s PortState bits take precedence over the port's 'portState'
				                     in port control unless the port's 'portState' is Disabled 
				                     (which prevents all frames from flowing).
				          MemberTag: Size: 2bits
				                     The lower two bits of each port's VTU data is called MemberTag.
				                     These bits are used to indicate which ports are members of
				                     the VLAN and if these VLANs frames should be tagged or
				                     untagged, or unmodified when exiting the port as follows:
				                     00 - Port is a member of this VLAN and frames are to egress unmodified.
				                     01 - Port is a member of this VLAN and frames are to egress Untagged.
				                     10 - Port is a member of this VLAN and frames are to egress Tagged.
				                     11 - Port is not a member of this VLAN"
			::= { oslam8g-VTU 7 }

		
		-- 1.3.6.1.4.1.11606.4.1.3.8
		vtuVIDPRI OBJECT-TYPE
			SYNTAX INTEGER (0..7)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"VID Priority
				============
				These bits are used to override the priority on any frames associated with this
				VID value, if the 'vtuVIDPRIOverride' is set to one."
			::= { oslam8g-VTU 8 }

		
		-- 1.3.6.1.4.1.11606.4.1.3.9
		vtuVIDPRIOverride OBJECT-TYPE
			SYNTAX INTEGER
				{
				noPriorityOverride(1),
				priorityOverride(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"VID Priority Override
				=====================
				1 - No priority override.
				2 - The vtuVIDPRI are used to override the priority on any frames associated 
				    with this VID as long as the port's 'portVTUPriOverride' is set.
				"
			::= { oslam8g-VTU 9 }

		
		-- 1.3.6.1.4.1.11606.4.1.4
		oslam8g-ATU OBJECT IDENTIFIER ::= { oslam8g-Global 4 }

		
		-- 1.3.6.1.4.1.11606.4.1.4.1
		atuOperation OBJECT-TYPE
			SYNTAX INTEGER
				{
				flushAllEntries(1),
				flushAllDynamicEntries(2),
				loadOrPurgeEntry(3),
				getNext(4),
				flushAllStaticIntriesInSelectedDBNum(5),
				flushAllDynamicEntriesInSelectedDBNum(6),
				getClearViolation(7),
				noOperation(8)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Address Translation Unit (ATU) Opcode:
				======================================
				1 - Flush All Entries
				2 - Flush all Non-Static Entries
				3 - Load or Purge an Entry in a particular atuDBNum Database
				4 - Get Next from a particular atuDBNum Database
				5 - Flush all Entries in a particular atuDBNum Database
				6 - Flush all Non-Static Entries in a particular atuDBNum Database
				7 - Get/Clear Violation Data.
				8 - No operation"
			::= { oslam8g-ATU 1 }

		
		-- 1.3.6.1.4.1.11606.4.1.4.2
		atuDBNum OBJECT-TYPE
			SYNTAX INTEGER (0..255)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"ATU MAC Address Database Number (DBNum)
				=======================================
				If multiple address databases are not being used theses bits must remain zero.
				If multiple address databases are being used theses are used to set the desired
				address database number that is being used on the Database supported commands
				(atuOperation 0x03, 0x04, 0x05 and 0x06). On Get/Clear Violation Data 
				atuOperation these bits return the atuDBNum value associated with the ATU
				violation that was just serviced."
			::= { oslam8g-ATU 2 }

		
		-- 1.3.6.1.4.1.11606.4.1.4.3
		atuMemberViolation OBJECT-TYPE
			SYNTAX INTEGER
				{
				noViolation(1),
				violation(2)
				}
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"ATU Member Violation
				==================
				On Get/Clear Violation operation this value is set to a two(2) if the 
				Violation being serviced is due to a Source Address Look-up that 
				resulted in a Hit but where the 'atuState' and 'atuPortVec' bits 
				does not contain the frame's Ingress port bit set to a two(2)
				(i.e. a station moved occurred). This violation can be masked on
				a per port basis by setting the port's ignoreWrongData bit. Only
				the first atuFullViolation, atuMemberViolation, atuMissViolation 
				is saved per port until cleared."
			::= { oslam8g-ATU 3 }

		
		-- 1.3.6.1.4.1.11606.4.1.4.4
		atuMissViolation OBJECT-TYPE
			SYNTAX INTEGER
				{
				noViolation(1),
				violation(2)
				}
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"ATU Miss Violation
				==================
				On Get/CLear Violation operation this value is set to a two(2) if the 
				Violation being serviced is due to a Source Address Look-up that 
				resulted in a Miss on ports that are locked (i.e., CPU directed 
				learning is enabled on the port). 
				
				Only the first atuFullViolation,
				atuMemberViolation, atuMissViolation is saved per port until cleared."
			::= { oslam8g-ATU 4 }

		
		-- 1.3.6.1.4.1.11606.4.1.4.5
		atuFullViolation OBJECT-TYPE
			SYNTAX INTEGER
				{
				noViolation(1),
				violation(2)
				}
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"ATU Full Violation
				==================
				On Get/Clear Violation operation this value is set to a two(2) if the 
				Violation being serviced is due to a Load operation or automatic 
				learn that could not store the desired entry. This only occurs if
				all available locations for the desired address contain other MAC
				addresses that are loaded Static. Only the first atuFullViolation,
				atuMemberViolation, atuMissViolation is saved per port until cleared."
			::= { oslam8g-ATU 5 }

		
		-- 1.3.6.1.4.1.11606.4.1.4.6
		atuAgeTime OBJECT-TYPE
			SYNTAX INTEGER (0..255)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"ATU Age Time
				============
				These bits determine the time that each ATU Entry remains valid in the database,
				since its last access as a source address, before being purged. The value in 
				this register times 15 is the age time in seconds. For example: The default value
				of 0x14 is 20 decimal. 20x15 = 300 seconds or 5 minutes. If the atuAgeTime is 0xFF
				or 3825 seconds or almost 64 minutes. if the atuAgeTime is set to 0 the Aging
				function is disabled and all learned addresses will remain in the database forever."
			::= { oslam8g-ATU 6 }

		
		-- 1.3.6.1.4.1.11606.4.1.4.7
		atuTrunkMode OBJECT-TYPE
			SYNTAX INTEGER
				{
				portVectorMode(1),
				trunkIDMode(2)
				}
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"TRUNK - Trunk Mappped Address
				=============================
				1 - The 'atuPortVec'  is the port vector assigned to this address.
				
				2 - The data bits [7:4] of 'atuPortVec' 
				is the Trunk ID assigned to this address. 'atuPortVec' bits [10:4]
				must be written as zero when this value is zet to a two(2).
				
				"
			::= { oslam8g-ATU 7 }

		
		-- 1.3.6.1.4.1.11606.4.1.4.8
		atuPortVecorTrunkID OBJECT-TYPE
			SYNTAX INTEGER (0..255)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Port Vector/Trunk ID
				====================
				If the atuTrunk is zero, theses bits are used as the input Port Vector 
				for ATU Load operations and it's the resulting Trunk ID for ATU load 
				operations and it's the resulting Trunk ID from ATU GetNext operations."
			::= { oslam8g-ATU 8 }

		
		-- 1.3.6.1.4.1.11606.4.1.4.9
		atuEntryState OBJECT-TYPE
			SYNTAX INTEGER (0..15)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"ATU Entry State
				===============
				Used as the Entry State for ATU Load/Purge or Flush/Move
				operations and it is the resulting Entry State from ATU Get Next operations
				(GetNext is the only ATU operation supported in the devices). If theses equal
				to 0x0 then the atuOperation is a Purge or a Flush. If theses bits are not 
				0x0 then the atuOperation is a Load or a Move (a move atuOperation requires
				these bits to be 0x0F). On Get/Clear Violation Data atuOperation, 
				theses bits return the Source Port ID(SPID) associated with the ATU 
				violation that was just serviced. If SPID = 0xF the source of the violation was
				the CPU's register interface (i.e. the ATU was full during a CPU Load operation)."
			::= { oslam8g-ATU 9 }

		
		-- 1.3.6.1.4.1.11606.4.1.4.10
		atuMACEntry OBJECT-TYPE
			SYNTAX Opaque (SIZE (6))
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"ATU MAC Address Entry:
				======================
				Byte pattern as follow:
				
				Opaque data Location:  5  4  3  2  1  0
				MAC Byte Location   : [5][4][3][2][1][0]"
			::= { oslam8g-ATU 10 }

		
-- OSLAM-8G Port Specific Status and Control
		-- 1.3.6.1.4.1.11606.4.2
		oslam8g-Port OBJECT IDENTIFIER ::= { oslam8g 2 }

		
		-- 1.3.6.1.4.1.11606.4.2.1
		oslam8gPortSelect OBJECT-TYPE
			SYNTAX INTEGER
			ACCESS read-write
			STATUS mandatory
			::= { oslam8g-Port 1 }

		
-- OSLAM-8G Port Control
		-- 1.3.6.1.4.1.11606.4.2.2
		oslam8g-portCtrl OBJECT IDENTIFIER ::= { oslam8g-Port 2 }

		
		-- 1.3.6.1.4.1.11606.4.2.2.1
		oslam8gPortForceFlowCtrl OBJECT-TYPE
			SYNTAX INTEGER
				{
				forceNoFlowCtrl(1),
				normal(2),
				forceFlowCtrl(3)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Force Flow Control Setting
				========================================
				1 - Force No Flow Control
				2 - Normal detection occurs
				3 - Force Flow Control"
			::= { oslam8g-portCtrl 1 }

		
		-- 1.3.6.1.4.1.11606.4.2.2.2
		oslam8gPortForceLink OBJECT-TYPE
			SYNTAX INTEGER
				{
				forceLinkDown(1),
				normal(2),
				forceLinkUp(3)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Force Link
				========================
				1 - Force to bring link down
				2 - Normal link detection occurs
				3 - Force to bring link up"
			::= { oslam8g-portCtrl 2 }

		
		-- 1.3.6.1.4.1.11606.4.2.2.3
		oslam8gPortForceDuplex OBJECT-TYPE
			SYNTAX INTEGER
				{
				forceHalfDuplex(1),
				normal(2),
				forceFullDuplexx(3)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Force Duplex Control
				==================================
				1 - Force Half-Duplex
				2 - Normal duplex detection occurs.
				3 - Force Full-Duplex"
			::= { oslam8g-portCtrl 3 }

		
		-- 1.3.6.1.4.1.11606.4.2.2.4
		oslam8gPortForceSpeed OBJECT-TYPE
			SYNTAX INTEGER
				{
				speed10Mbps(1),
				speed100Mbps(2),
				speed1000Mbps(3),
				speedAutoDetect(4)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Force Speed
				=========================
				1 - 10Mbps
				2 - 100Mbps
				3 - 1000Mbps
				4 - Speed is not forced. Normal speed detection occurs."
			::= { oslam8g-portCtrl 4 }

		
		-- 1.3.6.1.4.1.11606.4.2.2.5
		oslam8gPortPortState OBJECT-TYPE
			SYNTAX INTEGER
				{
				disabled(1),
				blockingListening(2),
				learning(3),
				forwarding(4)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port's Port State
				===========================
				This OID is used to manage a port to determine what kind of frames, 
				if any, are allowed to enter or leave a port for simple bridge loop
				detection or 802.1D Spanning Tree. This OID value can be change at 
				any time without disrupting frames currently in transmit.
				
				1 - Disabled. 
				    The port is disabled and it will not receive or transmit any frames.
				    The QC returns any pre-allocated ingress queue buffers when the 
				    port is in this mode.
				2 - Blocking/Listening. 
				    OSLAM-8G examines all frames without learning any SAs, and discards
				    all frames.
				3 - Learning.
				    OSLAM-8G will examine all frames, learning all SA address (except those
				    from MGMT frames), and still discard all but MGMT frames. It will allow
				    MGMT frames only to exit the port.
				4 - Forwarding.
				    OSLAM-8G examines all frames, learning SAs from all good frames (except 
				    those from MGMT frames), and receives and transmits all frames as a normal switch."
			::= { oslam8g-portCtrl 5 }

		
		-- 1.3.6.1.4.1.11606.4.2.2.6
		oslam8gPortFwdUnknown OBJECT-TYPE
			SYNTAX INTEGER
				{
				blockUnicastWithUnknownDA(1),
				normalForward(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Forward Unknown
				=============================
				1 - Unicast frames with unknown DAs will not egress out of this port.
				2 - Normal operation occurs and unicast frames with unknown DA addresses 
				    are allowed to egress out of this port (assuming the VLAN settings 
				    allow the frame to egress this port too)."
			::= { oslam8g-portCtrl 6 }

		
		-- 1.3.6.1.4.1.11606.4.2.2.7
		oslam8gPortDefFwd OBJECT-TYPE
			SYNTAX INTEGER
				{
				blockMulticastWithUnknownDA(1),
				normalForward(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Default Forward
				=============================
				1 - Multicast frames with unknown DAs do not egress from this port.
				2 - Normal switch operation occurs and multicast frames with unknown
				    DA addresses are allowed to egress out this port (assuming the
				    VLAN settings allow the frame to egress this port too)."
			::= { oslam8g-portCtrl 7 }

		
		-- 1.3.6.1.4.1.11606.4.2.2.8
		oslam8gPortUseIPForPriority OBJECT-TYPE
			SYNTAX INTEGER
				{
				useIPv4AndIPv6Priority(1),
				useIPv4OrIPv6Priority(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Use IP for Priority
				=================================
				Use IPv4 TOS and/or DiffServ fields and/or IPv6 Traffic Class fields, 
				if present, for priority data.
				
				1 - Ignore IPv4 and IPv6 priority fields.
				2 - Use IPv4 fields if the frame is IPv4 and use IPv6 fields 
				    if the frame is IPv6 for priority data.
				"
			::= { oslam8g-portCtrl 8 }

		
		-- 1.3.6.1.4.1.11606.4.2.2.9
		oslam8gPortUseCoreTag OBJECT-TYPE
			SYNTAX INTEGER
				{
				normal(1),
				useCoreTag(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Use Core Tag
				==========================
				Refer to 'oslam8gCoreTag'
				
				1 - Ingressing frames are considered tagged if the 16-bits 
				    following the frame's source Address are 0x8100.
				2 - Ingressing frames are considered tagged if the 16-bits
				    following the frame's source Address are equal to
				    'oslam8gCoreTagType'
				
				NOTE: 
				   If a frame is Double Tagged and the first tag is removed 
				   (oslam8gPortDoubleTag) by matching the EtherType define by
				   this bit, the resulting frame will be considered tagged 
				   only if the next 16 bits in the frame equal to 0x8100 
				   (that is, the oslam8gCoreTagType is not used after the
				   first tag is removed)"
			::= { oslam8g-portCtrl 9 }

		
		-- 1.3.6.1.4.1.11606.4.2.2.10
		oslam8gPortDoubleTag OBJECT-TYPE
			SYNTAX INTEGER
				{
				normal(1),
				useDoubleCoreTag(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Double Tag
				========================
				Ingress Double Tag
				
				2 - The ingressing frames are examined to see if they contain 802.3ac 
				    tag with the IEEE standard EtherType of 0x8100 or if they contain
				    a tag with an EtherType defined in oslam8gCoreTag. The oslam8gCoreTag
				    will be used if this port's oslam8gPortUseCoreTag is used. If the 
				    frames do contain the expected tag, the tag is removed (and the 
				    CRC is recomputed).
				
				    Essentially, untagged frames remain untagged, single tagged frames
				    become untagged and double tagged frames become single tagged. 
				    These now single tagged frames will be considered tagged only if 
				    its EtherType value is 0x8100 no matter what the EtherType value 
				    was found on the removed tag. No padding is performed so a tagged
				    frame must be at least 68bytes in size or it will be discarded.
				
				1 - Tagged frames are not modified when received.
				
				    The Tag data that is removed from the frame can be ignored 
				    (i.e., the frame is treated as if the removed tag never existed)
				    or the removed Tag data can be used for switching and priority
				    decisions (i.e., the removed Tag's VID and PRI bits are internally 
				    assigned to the frame). The action that is taken is controlled by
				    the oslam8gUseDoubleTagData"
			::= { oslam8g-portCtrl 10 }

		
-- OSLAM-8G Port Rate Control
		-- 1.3.6.1.4.1.11606.4.2.3
		oslam8g-portRateCtrl OBJECT IDENTIFIER ::= { oslam8g-Port 3 }

		
		-- 1.3.6.1.4.1.11606.4.2.3.1
		oslam8gPortEgressRate OBJECT-TYPE
			SYNTAX INTEGER (0..4095)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Egress Rate Limit
				================================
				Modify this port's effective transmission rate. This support 62kbps to 256Mbps.
				
				Formula to limit the Egress data rate:
				
				EgressRate = 8 bits/ (32ns * Egress Rate bits/sec)
				
				Where,
				=> Egress Rate is in bits per second.
				
				For example:
				============
				For 256Kbps rate the value of this oslam8gPortEgressRate should be:
				  = 8/(32ns * 256Kbps) = 976
				The value to be programmed for this OID is 976. 976 is actually equated to 256.14Kbps"
			::= { oslam8g-portRateCtrl 1 }

		
		-- 1.3.6.1.4.1.11606.4.2.3.2
		oslam8gPortIngressLimitMode OBJECT-TYPE
			SYNTAX INTEGER
				{
				limitAllFrames(1),
				limitBroadcastMulticastUnicastFrame(2),
				limitBroadcastMulticastFrame(3),
				limitBroadcastFrame(4)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Ingress Limit Mode
				================================
				Determine what kinds of frames are limited and counted against Ingress limiting.
				1 - Limit and count all frames.
				2 - Limit and count Broadcast, Multicast and flooded unicast frames.
				3 - Limit and count Broadcast and Multicast frames only.
				4 - Limit and count Broadcast frames only.
				
				NOTE: 
				If a frame is not limited by the above setting, its size is not counted against 
				the limit for the other frames."
			::= { oslam8g-portRateCtrl 2 }

		
		-- 1.3.6.1.4.1.11606.4.2.3.3
		oslam8gPortIngressPri3Rate OBJECT-TYPE
			SYNTAX INTEGER
				{
				useIngressPri2Rate(1),
				useTwiceIngressPri2Rate(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Priority 3 Rate Control
				=====================================
				Priority 3 frames are discarded after the ingress rate selected 
				below is reached or exceeded:
				1 - Use the same rate as oslam8gPortIngressPri2Rate
				2 - Use twice the rate as oslam8gPortIngressPri2Rate 
				    (but no faster than the port's speed)"
			::= { oslam8g-portRateCtrl 3 }

		
		-- 1.3.6.1.4.1.11606.4.2.3.4
		oslam8gPortIngressPri2Rate OBJECT-TYPE
			SYNTAX INTEGER
				{
				useIngressPri1Rate(1),
				useTwiceIngressPri1Rate(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Priority 2 Rate Control
				=====================================
				Priority 2 frames are discarded after the ingress rate selected 
				below is reached or exceeded:
				1 - Use the same rate as oslam8gPortIngressPri1Rate
				2 - Use twice the rate as oslam8gPortIngressPri1Rate 
				    (but no faster than the port's speed)"
			::= { oslam8g-portRateCtrl 4 }

		
		-- 1.3.6.1.4.1.11606.4.2.3.5
		oslam8gPortIngressPri1Rate OBJECT-TYPE
			SYNTAX INTEGER
				{
				useIngressPri0Rate(1),
				useTwiceIngressPri0Rate(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Priority 1 Rate Control
				=====================================
				Priority 1 frames are discarded after the ingress rate selected 
				below is reached or exceeded:
				1 - Use the same rate as oslam8gPortIngressPri0Rate
				2 - Use twice the rate as oslam8gPortIngressPri0Rate 
				    (but no faster than the port's speed)"
			::= { oslam8g-portRateCtrl 5 }

		
		-- 1.3.6.1.4.1.11606.4.2.3.6
		oslam8gPortIngressPri0Rate OBJECT-TYPE
			SYNTAX INTEGER (0..4095)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Priority 0 Rate Control
				=====================================
				Priority 1 frames are discarded after the ingress rate selected 
				below is reached or exceeded:
				
				OSLAM-8G use the following formula to calculate rate limiting:
				
				Pri0Rate = 8 bits/ (32ns * Ingress Rate bits/sec)
				
				Where,
				=> Ingress Rate is in bits per second.
				
				For example:
				============
				For 128Kbps rate the value of this oslam8gPortEgressRate should be:
				  = 8/(32ns * 128Kbps)
				  = 1953"
			::= { oslam8g-portRateCtrl 6 }

		
-- OSLAM-8G Port VLAN Specific Setting
		-- 1.3.6.1.4.1.11606.4.2.4
		oslam8g-PortVLAN OBJECT IDENTIFIER ::= { oslam8g-Port 4 }

		
		-- 1.3.6.1.4.1.11606.4.2.4.1
		oslam8gPortUseTag OBJECT-TYPE
			SYNTAX INTEGER
				{
				ignoreIEEE802dot1pTag(1),
				useIEEE802dot1pTag(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Use Tag
				=====================
				Use IEEE Tags. Use IEEE 802.1p Traffic Class field for priority data if 
				the frame is an IEEE 802.3ac tagged frame.
				1 - Ignore IEEE 802.1p tag fields even it the frame is tagged. 
				    In this mode, tagged frames that enter this port and egress the 
				    OSLAM-8G tagged are re-tagged with this port's default priority bits, 
				    if no other priorities are determined fro the frame (i.e., the frame's
				    IP priority and/or other priority overrides). This works as a Force 
				    Default Priority function on tagged frames.
				2 - Use IEEE 802.1p tag Traffic Class for priority data if the frame is tagged.
				"
			::= { oslam8g-PortVLAN 1 }

		
		-- 1.3.6.1.4.1.11606.4.2.4.2
		oslam8gPortPortMembership OBJECT-TYPE
			SYNTAX INTEGER (0..2047)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port's Port Membership
				===============================
				Port based VLAN Table. The bits in this value are used to restrict 
				which output ports this input port can send frames to. This value 
				are used for all frames even if 802.1Q is enabled on this port or 
				if ProtectedPort is enabled on this port. These bits restrict where
				a port can send frames (unless a oslam8gPortVLANTunnel frame is
				being received.
				
				=> To send frames to Port 0, bit 0 of this register must be a one.
				=> To send frames to Port 1, bit 1 of this register must be a one. etc.
				"
			::= { oslam8g-PortVLAN 2 }

		
		-- 1.3.6.1.4.1.11606.4.2.4.3
		oslam8gPortDefPri OBJECT-TYPE
			SYNTAX INTEGER (0..7)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Default Priority
				==============================
				Used as the default ingress priority to use when no other priority
				information is available (neither is the frame IEEE Tagged, nor is
				it an IPv4 nor an IPv6 frame - or the frame is a priority type that
				is currently disabled (see oslam8gPortUseIPPriority and oslam8gPortUseTag)
				and no other priority overrides are active on this frame. The default
				priority are remapped by the oslam8gPortPriRemap prior being used."
			::= { oslam8g-PortVLAN 3 }

		
		-- 1.3.6.1.4.1.11606.4.2.4.4
		oslam8gPort802dot1QMode OBJECT-TYPE
			SYNTAX INTEGER
				{
				portBasedVLANOnly(1),
				fallback802dot1Q(2),
				check802dot1Q(3),
				secure802dot1Q(4)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port 802.1Q Mode
				=========================
				IEEE 802.1Q Mode for this port. These bits determine if 802.1Q based 
				VLANs are used along with port based VLANs for this Ingress port. 
				If also determines the action to be taken if an 802.1Q VLAN Violation
				is detected.
				
				1 - 802.1Q disabled. 
				    Use Port Based VLANs only. The oslam8gPortMembership and 
				    oslam8gPortDefVID assigned to the frame during ingress 
				    determine which Egress ports this Ingress is allowed to
				    switch frames to for all frames.
				2 - Fallback.
				    Enable 802.1Q for this Ingress port. Do not discard Ingress
				    Membership violations and use the oslam8gPortMembership 
				    if the frame's VID is not contained in the VTU.
				3 - Check.
				    Enabled 802.1Q for this Ingress port. Do not discard Ingress
				    Membership violation but discard the frame if its VID is not
				    contained in the VTU.
				4 - Secure.
				    Enabled 802.1Q for this Ingress port. Do not discard Ingress
				    Membership violations and discard frames whose VID is not 
				    contained in the VTU.
				"
			::= { oslam8g-PortVLAN 4 }

		
		-- 1.3.6.1.4.1.11606.4.2.4.5
		oslam8gPortTagUntagDiscard OBJECT-TYPE
			SYNTAX INTEGER
				{
				noDiscard(1),
				discardUnTaggedFrames(2),
				discardTaggedFrames(3),
				discardBoth(4)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Tagged/Untagged Discard Mode
				==========================================
				1 - No discard of Frames
				2 - Only Discard Untagged Frames.
				    All non-MGMT frames that are processed as untagged are discarded 
				    as they entering this switch port. This test is performed after 
				    Ingress Double Tag removal (if enabled).
				3 - Only Discard Tagged Frames.
				    All non-MGMT frames that are processed as tagged are discarded 
				    as they entering this switch port.
				    This test is performed after Ingress Double Tag removal (if enabled).
				    Priority only tagged frames (with a VID of 0x00) are considered tagged.
				4 - Both Discard Tagged and Untagged frames."
			::= { oslam8g-PortVLAN 5 }

		
		-- 1.3.6.1.4.1.11606.4.2.4.6
		oslam8gPortDefVID OBJECT-TYPE
			SYNTAX INTEGER (0..4095)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Default VLAN Identifier
				=====================================
				When 802.1Q is enabled on this port this value is used as the IEEE 
				Tagged VID added to untagged or priority tagged frames during egress
				that ingressed from this port. It is also used as a tagged frame's 
				VID if the frame's VID was 0 (i.e., it is a priority tagged frame) 
				or if the port's oslam8gPortForceDefVID is set to one.
				
				When 802.1Q is disabled on this port, this value field is assigned
				to all frames entering the port (if are tagged or untagged). 
				This assignment is used internal to the switch, so only Port 
				Based VLANs can be supported."
			::= { oslam8g-PortVLAN 6 }

		
		-- 1.3.6.1.4.1.11606.4.2.4.7
		oslam8gPortVLANTunnel OBJECT-TYPE
			SYNTAX INTEGER
				{
				vlanNoTunnelling(1),
				vlanTunnelling(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port VLAN Tunnel
				=========================
				1 - The port based VLANs defined in oslam8gPortPortMembership, 
				    802.1Q VLANs defined in the oslam8g-802dot1QVLAN (if 802.1Q
				    is enabled) and oslam8gTrunkMask are enforced for ALL frames.
				
				2 - The port based oslam8gPortPortMembership, 802.1Q VLAN membership 
				    masking and oslam8gTrunkMask is bypassed for any frame entering
				    this port with a DA that is currently 'static' in the oslam8g-atu.
				    This applies to unicast as well as multicast frames."
			::= { oslam8g-PortVLAN 7 }

		
		-- 1.3.6.1.4.1.11606.4.2.4.8
		oslam8gPortVTUPriOverride OBJECT-TYPE
			SYNTAX INTEGER
				{
				normalPriority(1),
				vtuPriOverride(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port VTU Priority Override
				===================================
				1 - Normal frame priority processing occurs.
				2 - The VTU priority overrides can occur on this port. 
				    A VTU priority override occurs when the determined 
				    VID of a frame resuls in a VID whose oslam8gVTUVIDPRIOverride 
				    in the VTU VLAN database is set. When this occurs the VIDPRI 
				    value assigned to the frame's VID is used to overrite the frames
				    previously determined priority. If the frame egresses tagged the
				    priority in the frame will be this new VIDPRI value. When used
				    the upper two bits of the VIDPRI priority determine the Egress
				    Queue the frame is switched into. THE VTU Priority Override has 
				    higher priority than the port's Default Priority and the frame's
				    IEEE and/or IP priorities. The priority determined by the frame's
				    VID can be overridden, however, by the frame's SA and/or DA prority
				    Overrides."
			::= { oslam8g-PortVLAN 8 }

		
		-- 1.3.6.1.4.1.11606.4.2.4.9
		oslam8gPortForceDefVID OBJECT-TYPE
			SYNTAX INTEGER
				{
				vidNormal(1),
				forceDefaultVID(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Force Default VID
				===============================
				For to use Default VID. When 802.1Q is enabled on this port and 
				
				1 - All IEEE 802.3ac Tagged frames with a non-zero VID used the frame's 
				    VID unmodified.
				
				2 - All ingress frames with IEEE 802.3ac Tags have their VID 
				    ignored and the port's oslam8gPortDefaultVID is used and replaced into 
				    the frame instead. 
				
				When 802.1Q is disabled on this port, this bit has no effect."
			::= { oslam8g-PortVLAN 9 }

		
		-- 1.3.6.1.4.1.11606.4.2.4.10
		oslam8gEgressMode OBJECT-TYPE
			SYNTAX INTEGER
				{
				egressNormal(1),
				egressUntaggedRemoveTaggedFrame(2),
				egressTagAddToUntaggedFrame(3),
				egressAddAlways(4)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port Egress Mode
				=========================
				The first three Egrress Modes are used as the default Egress mode for 
				frames whose VID is not valid in the oslam8g-802dot1QVLAN or if 802.1Q
				is disabled on the port. The fourth Egress Mode is applied to all 
				frames all the time (if selected) even if 802.1Q is enabled on the port.
				
				1 - Default to Normal mode. Frames are transmitted unmodified.
				2 - Default to Transmit all frames Untagged. Remove the tag from 
				    any tagged frame.
				3 - Default to Transmit all frames Tagged. Add a tag to any untagged frame.
				4 - Always add a Tag (or Egress Double Tag). This setting is not a default 
				    setting. It ignores the MemberTag in vtuData of oslam8g-802dot1QVLAN 
				    for this port. The EtherType used for these inserted tags come from 
				    oslam8gCoreTag."
			::= { oslam8g-PortVLAN 10 }

		
		-- 1.3.6.1.4.1.11606.4.2.4.11
		oslam8gPortPriRemap OBJECT-TYPE
			SYNTAX Opaque (SIZE (4))
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"OSLAM-8G Port IEEE Priority Remapping
				====================================
				
				Byte#:            3                    2                    1                    0
				Format: [TagRemap7:TagRemap6][TagRemap5:TagRemap4][TagRemap3:TagRemap2][TagRemap1:TagRemap0]
				
				TagRemap0: Tag Remap 0. 
				           All IEEE tagged frames with a priority of 0 get this value as the frame's 
				           new priority inside the switch. If a tagged frame egresses the switch tagged,
				           this new priority is written to the frame's tag.
				
				TagRemap1: Tag Remap 1. 
				           All IEEE tagged frames with a priority of 1 get this value as the frame's 
				           new priority inside the switch. If a tagged frame egresses the switch tagged,
				           this new priority is written to the frame's tag.
				
				TagRemapX: Tag Remap X. 
				           All IEEE tagged frames with a priority of X get this value as the frame's 
				           new priority inside the switch. If a tagged frame egresses the switch tagged,
				           this new priority is written to the frame's tag."
			::= { oslam8g-PortVLAN 11 }

		
-- OSLAM-8G Port Status
		-- 1.3.6.1.4.1.11606.4.2.5
		oslam8g-portStatus OBJECT IDENTIFIER ::= { oslam8g-Port 5 }

		
		-- 1.3.6.1.4.1.11606.4.2.5.1
		oslam8gPortLinkStatus OBJECT-TYPE
			SYNTAX INTEGER
				{
				linkDown(1),
				linkUp(2)
				}
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Link Status:
				============
				This indicates the link status of the selected port
				
				1 - Link is down
				2 - Link is Up"
			::= { oslam8g-portStatus 1 }

		
		-- 1.3.6.1.4.1.11606.4.2.5.2
		oslam8gPortDuplexStatus OBJECT-TYPE
			SYNTAX INTEGER
				{
				halfDuplex(1),
				fullDuplex(2)
				}
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Duplex Mode:
				============
				Valid if link status is up.
				
				1 - Half-Duplex
				2 - Full-Duplex"
			::= { oslam8g-portStatus 2 }

		
		-- 1.3.6.1.4.1.11606.4.2.5.3
		oslam8gPortSpeedStatus OBJECT-TYPE
			SYNTAX INTEGER
				{
				speed10Mbps(1),
				speed100MBps(2),
				speed1000MBps(3),
				speedReserved(4)
				}
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Speed Mode:
				===========
				Valid if link status is up.
				
				1 - 10MBps
				2 - 100MBps
				3 - 1000MBps
				4 - Reserved for future used"
			::= { oslam8g-portStatus 3 }

		
-- OSLAM-8G Port Counters
		-- 1.3.6.1.4.1.11606.4.2.6
		oslam8g-portRMON OBJECT IDENTIFIER ::= { oslam8g-Port 6 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.1
		oslam8gPortRMONIngress OBJECT IDENTIFIER ::= { oslam8g-portRMON 1 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.1.1
		oslam8gPortInGoodOctetsLo OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONIngress 1 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.1.2
		oslam8gPortInGoodOctetsHi OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONIngress 2 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.1.3
		oslam8gPortInBadOctets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONIngress 3 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.1.4
		oslam8gPortInUnicast OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONIngress 4 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.1.5
		oslam8gPortInBroadcasts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONIngress 5 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.1.6
		oslam8gPortInMulticasts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONIngress 6 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.1.7
		oslam8gPortInPause OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONIngress 7 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.1.8
		oslam8gPortInUndersize OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONIngress 8 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.1.9
		oslam8gPortInFragments OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONIngress 9 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.1.10
		oslam8gPortInOversize OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONIngress 10 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.1.11
		oslam8gPortInJabber OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONIngress 11 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.1.12
		oslam8gPortInRxErr OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONIngress 12 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.1.13
		oslam8gPortInFCSErr OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONIngress 13 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.1.14
		oslam8gPortInDiscards OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONIngress 14 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.1.15
		oslam8gPortInFiltered OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONIngress 15 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.2
		oslam8gPortRMONEgress OBJECT IDENTIFIER ::= { oslam8g-portRMON 2 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.2.1
		oslam8gPortOutOctetsLo OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONEgress 1 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.2.2
		oslam8gPortOutOctetsHi OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONEgress 2 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.2.3
		oslam8gPortOutUnicast OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONEgress 3 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.2.4
		oslam8gPortOutBroadcasts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONEgress 4 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.2.5
		oslam8gPortOutMulticasts OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONEgress 5 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.2.6
		oslam8gPortOutPause OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONEgress 6 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.2.7
		oslam8gPortOutExcessive OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONEgress 7 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.2.8
		oslam8gPortOutCollisions OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONEgress 8 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.2.9
		oslam8gPortOutDeferred OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONEgress 9 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.2.10
		oslam8gPortOutSingle OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONEgress 10 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.2.11
		oslam8gPortOutMultiple OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONEgress 11 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.2.12
		oslam8gPortOutFCSErr OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONEgress 12 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.2.13
		oslam8gPortOutLate OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONEgress 13 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.2.14
		oslam8gPortOutFiltered OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortRMONEgress 14 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.3
		oslam8gPortHistogram OBJECT IDENTIFIER ::= { oslam8g-portRMON 3 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.3.1
		oslam8gPortHistogramMode OBJECT-TYPE
			SYNTAX INTEGER
				{
				countRxFramesOnly(1),
				countTxFramesOnly(2),
				countRxTxFrames(3)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Histogram Counters Mode:
				========================
				The Histogram mode control how the Histogram counters work as follows.
				
				1 - Count received frames only
				2 - Count transmitted frames only
				3 - Count receive and tranmitted frames"
			::= { oslam8gPortHistogram 1 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.3.2
		oslam8gPortOut64Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortHistogram 2 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.3.3
		oslam8gPortOut65to127Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortHistogram 3 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.3.4
		oslam8gPortOut128to255Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortHistogram 4 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.3.5
		oslam8gPortOut256to511Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortHistogram 5 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.3.6
		oslam8gPortOut512to1023Octets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortHistogram 6 }

		
		-- 1.3.6.1.4.1.11606.4.2.6.3.7
		oslam8gPortOut1024toMaxOctets OBJECT-TYPE
			SYNTAX Counter
			ACCESS read-only
			STATUS mandatory
			::= { oslam8gPortHistogram 7 }

		
		-- 1.3.6.1.4.1.11606.5
		fpcm OBJECT IDENTIFIER ::= { pbn 5 }

		
		-- 1.3.6.1.4.1.11606.5.1
		targetNodeAddress OBJECT-TYPE
			SYNTAX OCTET STRING (SIZE (10))
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Target Node Address:
				====================
				FPCM is a broadcast device. 10 digits decimal address required to
				access the target optical node. Value of 4294967295 represent a broadcast
				address i.e. message will be send to all connected node.
				This value is the serial number of the ODN4P-ABC."
			::= { fpcm 1 }

		
-- Access Control for ODN4P node
		-- 1.3.6.1.4.1.11606.5.2
		odn4pAccess OBJECT IDENTIFIER ::= { fpcm 2 }

		
		-- 1.3.6.1.4.1.11606.5.2.1
		odn4pABSwitchingMode OBJECT-TYPE
			SYNTAX INTEGER
				{
				manual(1),
				automatic(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"AB Switching Mode:
				==================
				The mode of operation for ODN4P-AB. Available operation mode are:
				- AUTOMATIC
				- MANUAL"
			::= { odn4pAccess 1 }

		
		-- 1.3.6.1.4.1.11606.5.2.2
		odn4pChannelSelect OBJECT-TYPE
			SYNTAX INTEGER
				{
				priOpt(1),
				secOpt(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Channel Select:
				===============
				The channel to be selected by the AB redundancy switch.
				Upon changing the channel, AB operation mode at the target
				device will change to MANUAL mode automatically."
			::= { odn4pAccess 2 }

		
		-- 1.3.6.1.4.1.11606.5.2.3
		odn4pSwitchingHysteresis OBJECT-TYPE
			SYNTAX INTEGER
				{
				neg3dot5dBmV(0),
				neg3dot0dBmV(1),
				neg2dot5dBmV(2),
				neg2dot0dBmV(3),
				neg1dot5dBmV(4),
				neg1dot0dBmV(5),
				neg0dot5dBmV(6),
				neg0dot0dBmV(7)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Switch Hysteresis:
				==================
				Primary Optical recovery level."
			::= { odn4pAccess 3 }

		
		-- 1.3.6.1.4.1.11606.5.2.4
		odn4pPrimarySwitchOverTime OBJECT-TYPE
			SYNTAX INTEGER (1..15)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Primary switch-over time:
				=========================
				The number of second wait required before change of state"
			::= { odn4pAccess 4 }

		
		-- 1.3.6.1.4.1.11606.5.2.5
		odn4pSecondarySwitchOverTime OBJECT-TYPE
			SYNTAX INTEGER (1..15)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Secondary switch-over time:
				===========================
				The number of second wait required before change of state"
			::= { odn4pAccess 5 }

		
		-- 1.3.6.1.4.1.11606.5.2.6
		odn4pAttenuator1 OBJECT-TYPE
			SYNTAX INTEGER (2..40)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Attenuator 1:
				=============
				Attenuation used for ingress control.
				Unit is in 1dB step.
				Acceptable value range: 2-40dB"
			::= { odn4pAccess 6 }

		
		-- 1.3.6.1.4.1.11606.5.2.7
		odn4pAttenuator2 OBJECT-TYPE
			SYNTAX INTEGER (2..40)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Attenuator 2:
				=============
				Attenuation used for ingress control.
				Unit is in 1dB step.
				Acceptable value range: 2-40dB"
			::= { odn4pAccess 7 }

		
		-- 1.3.6.1.4.1.11606.5.2.8
		odn4pAttenuator3 OBJECT-TYPE
			SYNTAX INTEGER (2..40)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Attenuator 3:
				=============
				Attenuation used for ingress control.
				Unit is in 1dB step.
				Acceptable value range: 2-40dB"
			::= { odn4pAccess 8 }

		
		-- 1.3.6.1.4.1.11606.5.2.9
		odn4pAttenuator4 OBJECT-TYPE
			SYNTAX INTEGER (2..40)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Attenuator 4:
				=============
				Attenuation used for ingress control.
				Unit is in 1dB step.
				Acceptable value range: 2-40dB"
			::= { odn4pAccess 9 }

		
		-- 1.3.6.1.4.1.11606.5.2.10
		odn4pHomeFskChannel OBJECT-TYPE
			SYNTAX INTEGER (0..100)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Remote node FSK home channel:
				=============================
				Each network may use different default FSK channel.
				This is the default FSK channel to be managed by operator.
				Optical node always tune to home channel prior to agility."
			::= { odn4pAccess 10 }

		
		-- 1.3.6.1.4.1.11606.5.2.11
		odn4pFskMode OBJECT-TYPE
			SYNTAX INTEGER
				{
				fskFix(1),
				fskAgile(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"FSK Operating mode
				==================
				Force FSK to operate in either FIX or AGILE mode.
				FIX - FSK receiver always try to lock to the known FSK frequency
				AGILE - Always search for an FSK channel that is capable of decoding data
				"
			::= { odn4pAccess 11 }

		
		-- 1.3.6.1.4.1.11606.5.2.12
		odn4pLoopTest OBJECT-TYPE
			SYNTAX INTEGER
				{
				uidSrcAddr0(22),
				uidSrcAddr1(23),
				uidSrcAddr2(24),
				uidSrcAddr3(25),
				uidAddr0(26),
				uidAddr1(27),
				uidAddr2(28),
				uidAddr3(29),
				uidMajorVer(30),
				uidMinorVer(31),
				uidAtten0(33),
				uidAtten1(34),
				uidAtten2(35),
				uidAtten3(36),
				uidFSKCh(48),
				uidFSKMode(50),
				uidPassTest112(112),
				uidPassTest113(113),
				uidPassTest114(114),
				uidPassTest115(115),
				uidPassTest116(116),
				uidPassTest117(117),
				uidPassTest118(118),
				uidPassTest119(119),
				uidPassTest120(120),
				uidPassTest121(121),
				uidPassTest122(122),
				uidPassTest123(123),
				uidPassTest124(124),
				uidPassTest125(125),
				uidPassTest126(126),
				uidPassTest127(127),
				uidModeSel(129),
				uidInpSel(130),
				uidPriRefLvl(131),
				uidPriSwtTime(132),
				uidSecSwtTime(133),
				uidModeChgCnt(134),
				uidInpChgCnt(135),
				uidClearTest(251)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"ODN4P LOOP TEST
				===============
				Acceptable value is 0-255 or 8-bit number.
				Value between between 1..255 will be display on the connected 
				RPQRM of the selected channel if this OID has been iniated.
				Set value to 0xFB will clear loopback test and normal data will 
				then be seen in the RPQRM.
				Operator should only use value between 0x70 to 0x7F for testing
				Other values are reserved for NETCRAFT
				
				"
			::= { odn4pAccess 12 }

		
-- Node Access Control:
-- ====================
-- This usually used by remote management software (NMS3)
-- Operator should ignore or do not change these OID value.
		-- 1.3.6.1.4.1.11606.5.3
		nodeAccess OBJECT IDENTIFIER ::= { fpcm 3 }

		
		-- 1.3.6.1.4.1.11606.5.3.1
		nodeAccessDataLength OBJECT-TYPE
			SYNTAX INTEGER
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Node Access Control Data Length:
				================================
				This usually used by remote management software (NMS3)
				Operator should ignore or do not change this OID value."
			::= { nodeAccess 1 }

		
		-- 1.3.6.1.4.1.11606.5.3.2
		nodeAccessData OBJECT-TYPE
			SYNTAX Opaque (SIZE (0..32))
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Node Access Control Data:
				=========================
				This usually used by remote management software (NMS3)
				Operator should ignore or do not change this OID value."
			::= { nodeAccess 2 }

		
		-- 1.3.6.1.4.1.11606.5.3.3
		nodeAccessCmd OBJECT-TYPE
			SYNTAX INTEGER (0..255)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Node Access Control Command:
				============================
				This usually used by remote management software (NMS3)
				Operator should ignore or do not change this OID value."
			::= { nodeAccess 3 }

		
-- FPCM FSK Modulation Control
		-- 1.3.6.1.4.1.11606.5.4
		fpcmCtrl OBJECT IDENTIFIER ::= { fpcm 4 }

		
		-- 1.3.6.1.4.1.11606.5.4.1
		fpcmFSKChannel OBJECT-TYPE
			SYNTAX INTEGER (0..100)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"FSK Channel modulated by FPCM:
				==============================
				Acceptable FSK channel range 0-100.
				FSK modulation range 80-90MHz (Channel 0-100 respectively)"
			::= { fpcmCtrl 1 }

		
		-- 1.3.6.1.4.1.11606.5.4.2
		fpcmRFLevel OBJECT-TYPE
			SYNTAX INTEGER (25..45)
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"FPCM RF level
				=============
				RF level setting in 1dBmV scale.
				Current supported value is 25-45dBmV"
			::= { fpcmCtrl 2 }

		
		-- 1.3.6.1.4.1.11606.6
		mau OBJECT IDENTIFIER ::= { pbn 6 }

		
-- Product Information Tree
		-- 1.3.6.1.4.1.11606.6.1
		mauProductInfo OBJECT IDENTIFIER ::= { mau 1 }

		
		-- 1.3.6.1.4.1.11606.6.1.1
		mauProductModelName OBJECT-TYPE
			SYNTAX OCTET STRING
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Product model name"
			::= { mauProductInfo 1 }

		
		-- 1.3.6.1.4.1.11606.6.1.2
		mauProductVersion OBJECT-TYPE
			SYNTAX OCTET STRING
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Product version number"
			::= { mauProductInfo 2 }

		
		-- 1.3.6.1.4.1.11606.6.1.3
		mauProductVersionDate OBJECT-TYPE
			SYNTAX OCTET STRING
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Product build date"
			::= { mauProductInfo 3 }

		
		-- 1.3.6.1.4.1.11606.6.1.4
		mauProductMAC OBJECT-TYPE
			SYNTAX OCTET STRING (SIZE (6))
			ACCESS read-only
			STATUS mandatory
			::= { mauProductInfo 4 }

		
		-- 1.3.6.1.4.1.11606.6.1.5
		mauProductSerialNumber OBJECT-TYPE
			SYNTAX OCTET STRING (SIZE (6))
			ACCESS read-only
			STATUS mandatory
			::= { mauProductInfo 5 }

		
-- Monitoring OID which is read-only.
		-- 1.3.6.1.4.1.11606.6.2
		mauStatus OBJECT IDENTIFIER ::= { mau 2 }

		
		-- 1.3.6.1.4.1.11606.6.2.1
		mauStatusVACType OBJECT-TYPE
			SYNTAX TypePowerSupply
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"VAC input type. e.g. '220V'"
			::= { mauStatus 1 }

		
		-- 1.3.6.1.4.1.11606.6.2.2
		mauStatus5V OBJECT-TYPE
			SYNTAX OCTET STRING
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"+5V supply voltage level. 
				Unit is in Volt e.g. 4.92V"
			::= { mauStatus 2 }

		
		-- 1.3.6.1.4.1.11606.6.2.3
		mauStatus12V OBJECT-TYPE
			SYNTAX OCTET STRING
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"+12V supply voltage level. 
				Unit is in Volt e.g. 12.00V"
			::= { mauStatus 3 }

		
		-- 1.3.6.1.4.1.11606.6.2.4
		mauStatus24V OBJECT-TYPE
			SYNTAX OCTET STRING
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"+24V supply voltage level. 
				Unit is in Volt e.g. 24.10V"
			::= { mauStatus 4 }

		
		-- 1.3.6.1.4.1.11606.6.2.5
		mauStatusInputOpticalPower OBJECT-TYPE
			SYNTAX OCTET STRING
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Optical input power level.
				Unit is in dBm e.g. -2.05dBm"
			::= { mauStatus 5 }

		
		-- 1.3.6.1.4.1.11606.6.2.6
		mauStatusOutputOpticalPower OBJECT-TYPE
			SYNTAX OCTET STRING
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Optical input power level.
				Unit is in dBm e.g. -2.05dBm"
			::= { mauStatus 6 }

		
		-- 1.3.6.1.4.1.11606.6.2.7
		mauStatusRFOutputPower OBJECT-TYPE
			SYNTAX OCTET STRING
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Total RF output power level.
				Unit is in dBmV e.g. 41.23dBmV total or 25.00dBmV/Ch@42Ch."
			::= { mauStatus 7 }

		
		-- 1.3.6.1.4.1.11606.6.2.8
		mauStatusTemperature OBJECT-TYPE
			SYNTAX OCTET STRING
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Module internal temperature. 
				Unit is in Degree Celsius e.g. 29.25C"
			::= { mauStatus 8 }

		
		-- 1.3.6.1.4.1.11606.6.2.9
		mauStatusLid OBJECT-TYPE
			SYNTAX TypeTamper
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Device lid open/close status"
			::= { mauStatus 9 }

		
		-- 1.3.6.1.4.1.11606.6.2.10
		mauStatusONUInstalled OBJECT-TYPE
			SYNTAX TypeYesNo
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"EPON-ONU installed status."
			::= { mauStatus 10 }

		
		-- 1.3.6.1.4.1.11606.6.2.11
		mauStatusMOCAInstalled OBJECT-TYPE
			SYNTAX TypeYesNo
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"MOCA installed status."
			::= { mauStatus 11 }

		
		-- 1.3.6.1.4.1.11606.6.2.12
		mauStatusPLCInstalled OBJECT-TYPE
			SYNTAX TypeYesNo
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"PLC installed status."
			::= { mauStatus 12 }

		
		-- 1.3.6.1.4.1.11606.6.2.13
		mauStatusLED OBJECT-TYPE
			SYNTAX TypeOnOff
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Status LED"
			::= { mauStatus 13 }

		
		-- 1.3.6.1.4.1.11606.6.2.14
		mauStatusGainControlLED OBJECT-TYPE
			SYNTAX TypeOnOff
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Gain control LED (AGC/MGC) status.
				ON  - AGC mode
				OFF - MGC mode"
			::= { mauStatus 14 }

		
		-- 1.3.6.1.4.1.11606.6.2.15
		mauStatusOpticalInputHighLED OBJECT-TYPE
			SYNTAX TypeOnOff
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Optical input high led indicator
				ON  - Optical input is too high."
			::= { mauStatus 15 }

		
		-- 1.3.6.1.4.1.11606.6.2.16
		mauStatusOpticalInputLowLED OBJECT-TYPE
			SYNTAX TypeOnOff
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Optical input LOW led indicator
				ON  - Optical input is too low."
			::= { mauStatus 16 }

		
		-- 1.3.6.1.4.1.11606.6.2.17
		mauStatus5VMin OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"+5V Supply MIN voltage alarm level"
			::= { mauStatus 17 }

		
		-- 1.3.6.1.4.1.11606.6.2.18
		mauStatus5VMax OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"+5V Supply MAX voltage alarm level"
			::= { mauStatus 18 }

		
		-- 1.3.6.1.4.1.11606.6.2.19
		mauStatus12VMin OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"+12V Supply MIN voltage alarm level"
			::= { mauStatus 19 }

		
		-- 1.3.6.1.4.1.11606.6.2.20
		mauStatus12VMax OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"+12V Supply MAX voltage alarm level"
			::= { mauStatus 20 }

		
		-- 1.3.6.1.4.1.11606.6.2.21
		mauStatus24VMin OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"+24V Supply MIN voltage alarm level"
			::= { mauStatus 21 }

		
		-- 1.3.6.1.4.1.11606.6.2.22
		mauStatus24VMax OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"+24V Supply MAX voltage alarm level"
			::= { mauStatus 22 }

		
		-- 1.3.6.1.4.1.11606.6.2.23
		mauStatusInputOpticalPowerMin OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Optical Input Power MIN alarm level"
			::= { mauStatus 23 }

		
		-- 1.3.6.1.4.1.11606.6.2.24
		mauStatusInputOpticalPowerMax OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Optical Input Power MAX alarm level"
			::= { mauStatus 24 }

		
		-- 1.3.6.1.4.1.11606.6.2.25
		mauStatusOutputOpticalPowerMin OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Optical Output Power MIN alarm level"
			::= { mauStatus 25 }

		
		-- 1.3.6.1.4.1.11606.6.2.26
		mauStatusOutputOpticalPowerMax OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Optical Output Power MAX alarm level"
			::= { mauStatus 26 }

		
		-- 1.3.6.1.4.1.11606.6.2.27
		mauStatusTemperatureMin OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Temperature MIN alarm level"
			::= { mauStatus 27 }

		
		-- 1.3.6.1.4.1.11606.6.2.28
		mauStatusTemperatureMax OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Temperature MAX alarm level"
			::= { mauStatus 28 }

		
		-- 1.3.6.1.4.1.11606.6.2.29
		mauStatusGainControlMin OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Gain Control MIN Level"
			::= { mauStatus 29 }

		
		-- 1.3.6.1.4.1.11606.6.2.30
		mauStatusGainControlMax OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Gain Control MAX Level"
			::= { mauStatus 30 }

		
		-- 1.3.6.1.4.1.11606.6.2.31
		mauStatusAgcLock OBJECT-TYPE
			SYNTAX TypeAGCStatus
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"AGC lock when the controlled signal is within range.
				AGC unlock when agc cannot control the signal or signal is out of range for AGC to operate."
			::= { mauStatus 31 }

		
		-- 1.3.6.1.4.1.11606.6.3
		mauControl OBJECT IDENTIFIER ::= { mau 3 }

		
		-- 1.3.6.1.4.1.11606.6.3.1
		mauGainControlMode OBJECT-TYPE
			SYNTAX TypeGainMode
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"RF gain control setting.
				1dB control step. 
				Control range to be adviced."
			::= { mauControl 1 }

		
		-- 1.3.6.1.4.1.11606.6.3.2
		mauTrapEnabled OBJECT-TYPE
			SYNTAX INTEGER
				{
				trapDisabled(1),
				trapEnabled(2)
				}
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Indicates if this trap entry is enabled or not."
			::= { mauControl 2 }

		
		-- 1.3.6.1.4.1.11606.6.3.3
		mauPrimaryCommunity OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Primary Community String to be used by agent for SNMP GET/SET for mauTrapPrimaryReceiverIPAddress"
			::= { mauControl 3 }

		
		-- 1.3.6.1.4.1.11606.6.3.4
		mauSecondaryCommunity OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Secondary Community String to be used by agent for SNMP GET/SET for mauTrapSecondaryReceiverIPAddress"
			::= { mauControl 4 }

		
		-- 1.3.6.1.4.1.11606.6.3.5
		mauPrimaryTrapReceiverIPAddress OBJECT-TYPE
			SYNTAX IpAddress
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"The primary Trap Receiver station IP address"
			::= { mauControl 5 }

		
		-- 1.3.6.1.4.1.11606.6.3.6
		mauSecondaryTrapReceiverIPAddress OBJECT-TYPE
			SYNTAX IpAddress
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"The secondary Trap Receiver station IP address"
			::= { mauControl 6 }

		
		-- 1.3.6.1.4.1.11606.6.4
		mauTraps OBJECT IDENTIFIER ::= { mau 4 }

		
		-- 1.3.6.1.4.1.11606.6.4.1
		mauTrapMessageDescr OBJECT-TYPE
			SYNTAX DisplayString
			ACCESS read-write
			STATUS mandatory
			::= { mauTraps 1 }
                                 
                                 
		-- 1.3.6.1.4.1.11606.7
		lte153 OBJECT IDENTIFIER ::= { pbn 7 }
		
-- Product Information Tree
		-- 1.3.6.1.4.1.11606.7.1
		lte153Laser OBJECT IDENTIFIER ::= { lte153 1 }    
		
		tagID                 OBJECT-TYPE
		    SYNTAX            OCTET STRING (SIZE(0..23))
		    MAX-ACCESS        read-write
		    STATUS            current
		    DESCRIPTION       "Displays the tag name of the device in human-readable format as set by user."
		    ::= { lte153Laser 1 }
		
		modelNumber           OBJECT-TYPE
		    SYNTAX            OCTET STRING (SIZE(0..23))
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Displays the name of the device model number in human-readable format as set from the factory."
		    ::= { lte153Laser 2 }
		
		mfgDate               OBJECT-TYPE
		    SYNTAX            OCTET STRING (SIZE(0..23))
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Displays the manufacturing date in human-readable format as set from the factory."
		    ::= { lte153Laser 3 }
		
		serialNum             OBJECT-TYPE
		    SYNTAX            OCTET STRING (SIZE(0..23))
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Displays the serial number in human-readable format as set from the factory."
		    ::= { lte153Laser 4 }
		
		firmwareRev           OBJECT-TYPE
		    SYNTAX            OCTET STRING (SIZE(0..23))
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Displays the software revision of the device in human-readable format."
		    ::= { lte153Laser 5 }
		
		engRev                OBJECT-TYPE
		    SYNTAX            OCTET STRING (SIZE(0..23))
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Displays the engineering revision in human-readable format as set from the factory."
		    ::= { lte153Laser 6 }
		
		systemTemp            OBJECT-TYPE
		    SYNTAX            Integer32(-500..1200)
		    UNITS             "tenth of a Celsius degree(C)"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the unit temperature."
		    ::= { lte153Laser 7 }
		
		laserCurrent          OBJECT-TYPE
		    SYNTAX            Integer32(0..1250)
		    UNITS             "milliampere(mA)"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns measured laser bias current."
		    ::= { lte153Laser 8 }
		     
		laserTemperature      OBJECT-TYPE
		    SYNTAX            Integer32(-500..800)
		    UNITS             "tenth of a Celsius degree(C)"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the measured laser temperature."
		    ::= { lte153Laser 9 }
		        
		inputRFLevel          OBJECT-TYPE
		    SYNTAX            Integer32(-1000..100)
		    UNITS             "tenth of a decibel(dB)"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the input RF level."
		    ::= { lte153Laser 10 }
		
		compositeRFLevel      OBJECT-TYPE
		    SYNTAX            Integer32(-1000..100)
		    UNITS             "tenth of a decibel(dB)"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the measured composite RF level." 
		    ::= { lte153Laser 11 }
		 
		opticalPowerOut1      OBJECT-TYPE
		    SYNTAX            Integer32(-1000..200)
		    UNITS             "tenth of decibel relative to one milliwatt(dBm)"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the optical power output for port 1."
		    ::= { lte153Laser 12 }
		
		opticalPowerOut2      OBJECT-TYPE
		    SYNTAX            Integer32(-1000..200)
		    UNITS             "tenth of decibel relative to one milliwatt(dBm)"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the optical power output for port 2."
		    ::= { lte153Laser 13 }
		
		tecCurrent            OBJECT-TYPE
		    SYNTAX            Integer32(-25000..25000)
		    UNITS             "milliampere(mA)"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the current of thermoelectric cooler inside the laser asssembly."
		    ::= { lte153Laser 14 }
		        
		attenuationSet        OBJECT-TYPE
		    SYNTAX            Integer32(-70..30)
		    UNITS             "tenth of a decibel(dB)"
		    MAX-ACCESS        read-write
		    STATUS            current
		    DESCRIPTION       "Manual mode RF attenuator setpoint." 
		    ::= { lte153Laser 15 }
		 
		omiSetpoint           OBJECT-TYPE
		    SYNTAX            Integer32(-30..30)
		    UNITS             "tenth of a decibel(dB)"
		    MAX-ACCESS        read-write
		    STATUS            current
		    DESCRIPTION       "Optical modulation index is implemented for CW or Video AGC modes as RF attenuator setpoint." 
		    ::= { lte153Laser 16 }
		 
		agcMode              OBJECT-TYPE
		    SYNTAX            INTEGER { undefined(0),manual(1),cw(2),video(3),invalidMode(4) }
		    UNITS             "no units"
		    MAX-ACCESS        read-write
		    STATUS            current
		    DESCRIPTION       "Returns the AGC mode." 
		    ::= { lte153Laser 17 }
		 
		sbsSuppression        OBJECT-TYPE
		    SYNTAX            Integer32(140..180)
		    UNITS             "tenth of a decibel relative to one milliwatt(dBm)"
		    MAX-ACCESS        read-write
		    STATUS            current
		    DESCRIPTION       "SBS suppression level." 
		    ::= { lte153Laser 18 }
		 
		fiberDispersionCntl   OBJECT-TYPE
		    SYNTAX            INTEGER { undefined(0),off(1),on(2) }
		    UNITS             "no units"
		    MAX-ACCESS        read-write
		    STATUS            current
		    DESCRIPTION       "Fiber dispersion compensation On/Off control." 
		    ::= { lte153Laser 19 }
		 
		fiberDispersionGain   OBJECT-TYPE
		    SYNTAX            Integer32(-40..40)
		    UNITS             "tenth of a volt"
		    MAX-ACCESS        read-write
		    STATUS            current
		    DESCRIPTION       "Fiber dispersion gain compensation." 
		    ::= { lte153Laser 20 }
		 
		fiberDispersionPhase  OBJECT-TYPE
		    SYNTAX            Integer32(-40..40)
		    UNITS             "tenth of a volt"
		    MAX-ACCESS        read-write
		    STATUS            current
		    DESCRIPTION       "Fiber dispersion phase compensation." 
		    ::= { lte153Laser 21 }
		 
		fiberDispersionSlope  OBJECT-TYPE
		    SYNTAX            Integer32(-40..40)
		    UNITS             "tenth of a volt"
		    MAX-ACCESS        read-write
		    STATUS            current
		    DESCRIPTION       "Fiber dispersion slope compensation." 
		    ::= { lte153Laser 22 }
		 
		laserOnOff            OBJECT-TYPE
		    SYNTAX            INTEGER { undefined(0),off(1),on(2) }
		    UNITS             "no units"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "returns the active laser On/Off status." 
		    ::= { lte153Laser 23 }
		 
		keyswitch             OBJECT-TYPE
		    SYNTAX            INTEGER { undefined(0),off(1),on(2) }
		    UNITS             "no units"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the status of the front panel keyswitch." 
		    ::= { lte153Laser 24 }
		 
		remoteLaserControl    OBJECT-TYPE
		    SYNTAX            INTEGER { undefined(0),off(1),on(2) }
		    UNITS             "no units"
		    MAX-ACCESS        read-write
		    STATUS            current
		    DESCRIPTION       "Remote laser On/Off control." 
		    ::= { lte153Laser 25 }
		 
		resetCause            OBJECT-TYPE
		    SYNTAX            INTEGER { undefined(0),other(1),powerup(2),command(3),watchdog(4),craft(5) }
		    UNITS             "no units"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "This object reports the cause of the last reset." 
		    ::= { lte153Laser 26 }
		 
		resetControl          OBJECT-TYPE
		    SYNTAX            INTEGER { undefined(0),reset(1) }
		    UNITS             "no units"
		    MAX-ACCESS        read-write
		    STATUS            current
		    DESCRIPTION       "This object is used to reset the transmitter module by writing a 1 to it.
		                       Other values written to the object have no effect.
		                       Reading the object returns a 1 and has no effect on the module.
		                      " 
		    ::= { lte153Laser 27 }
		 
		sbs2GHzPower          OBJECT-TYPE
		    SYNTAX            Integer32(-300..300)
		    UNITS             "tenth of a decibel relative to one milliwatt(dBm)"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "2GHz SBS output power level." 
		    ::= { lte153Laser 28 }
		 
		sbs6GHzPower          OBJECT-TYPE
		    SYNTAX            Integer32(-300..300)
		    UNITS             "tenth of a decibel relative to one milliwatt(dBm)"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "6GHz SBS output power level." 
		    ::= { lte153Laser 29 }
		 
		monitor5v             OBJECT-TYPE
		    SYNTAX            Integer32(0..70)
		    UNITS             "tenth of a volt(V)"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the measured value of the +5V supply."
		    ::= { lte153Laser 30 }    
		    
		monitor12v            OBJECT-TYPE
		    SYNTAX            Integer32(0..150)
		    UNITS             "tenth of a volt(V)"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the measured value of the +12V supply."
		    ::= { lte153Laser 31 }    
		    
		monitor24v            OBJECT-TYPE
		    SYNTAX            Integer32(0..300)
		    UNITS             "tenth of a volt(V)"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the measured value of the +24V supply."
		    ::= { lte153Laser 32 }    
		    
		monitorM5v            OBJECT-TYPE
		    SYNTAX            Integer32(-70..70)
		    UNITS             "tenth of a volt(V)"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the measured value of the -5V supply."
		    ::= { lte153Laser 33 }    
		    
		monitorM12v           OBJECT-TYPE
		    SYNTAX            Integer32(-150..150)
		    UNITS             "tenth of a volt(V)"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the measured value of the -12V supply."
		    ::= { lte153Laser 34 }    
		    
		unitStatusEnable      OBJECT-TYPE
		    SYNTAX            BITS 
		                      {
		                       systemTempHigh(0),
		                       systemTempLow(1),
		                       laserCurrentHigh(2),
		                       laserCurrentLow(3),
		                       laserTempHigh(4),
		                       laserTempLow(5),
		                       inputRFHigh(6),
		                       inputRFLow(7),
		                       opticalPowerHigh(8),
		                       opticalPowerLow(9),
		                       tecCurrentHigh(10),
		                       agcUnlock(11),
		                       keyInOffPosition(12),
		                       remoteOffModeSet(13)
		                      }
		    UNITS             "no units"
		    MAX-ACCESS        read-write
		    STATUS            current
		    DESCRIPTION       "Indicates the unit status alarm enable. This
		                       value is bit encoded therefore it is capable
		                       of indicating multiple alarm enable conditions. 
		                       The bits are defined as follows:
		
		                           0       1       2       3       4       5       6       7    
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       |System |System | Laser | Laser | Laser | Laser | Input | Input |
		                       | Temp  | Temp  |Current|Current| Temp  | Temp  |  RF   |  RF   |
		                       | High  | Low   | High  |  Low  | High  | Low   | Level | Level |
		                       |       |       |       |       |       |       |  High |  Low  |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		
		                           8       9       10      11      12      13      14      15   
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       |Optical|Optical| TEC   |  AGC  |Key in |Remote |       |       |
		                       | Power | Power |Current| Unlock| Off   | Off   |       |       |
		                       |  Out  |  Out  | High  |       |Position Mode  |       |       |
		                       |  High |  Low  |       |       |       | Set   |       |       |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                      "
		    ::= { lte153Laser 35 }
		 
		unitStatusMajor       OBJECT-TYPE
		    SYNTAX            BITS 
		                      {
		                       systemTempHigh(0),
		                       systemTempLow(1),
		                       laserCurrentHigh(2),
		                       laserCurrentLow(3),
		                       laserTempHigh(4),
		                       laserTempLow(5),
		                       inputRFHigh(6),
		                       inputRFLow(7),
		                       opticalPowerHigh(8),
		                       opticalPowerLow(9),
		                       tecCurrentHigh(10),
		                       agcUnlock(11),
		                       keyInOffPosition(12),
		                       remoteOffModeSet(13)
		                      }
		    UNITS             "no units"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns a bit mapped status word where each bit set (as defined below) 
		                       indicates a specific active alarm:
		
		                           0       1       2       3       4       5       6       7    
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       |System |System | Laser | Laser | Laser | Laser | Input | Input |
		                       | Temp  | Temp  |Current|Current| Temp  | Temp  |  RF   |  RF   |
		                       | High  | Low   | High  |  Low  | High  | Low   | Level | Level |
		                       |       |       |       |       |       |       |  High |  Low  |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		
		                           8       9       10      11      12      13      14      15   
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       |Optical|Optical| TEC   |  AGC  |Key in |Remote |       |       |
		                       | Power | Power |Current| Unlock| Off   | Off   |       |       |
		                       |  Out  |  Out  | High  |       |Position Mode  |       |       |
		                       |       |       |       |       |       | Set   |       |       |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                      "
		    ::= { lte153Laser 36 }
		   
		unitStatusMinor       OBJECT-TYPE
		    SYNTAX            BITS 
		                      {
		                       systemTempHigh(0),
		                       systemTempLow(1),
		                       laserCurrentHigh(2),
		                       laserCurrentLow(3),
		                       laserTempHigh(4),
		                       laserTempLow(5),
		                       inputRFHigh(6),
		                       inputRFLow(7),
		                       opticalPowerHigh(8),
		                       opticalPowerLow(9),
		                       tecCurrentHigh(10),
		                       agcUnlock(11),
		                       keyInOffPosition(12),
		                       remoteOffModeSet(13)
		                      }
		    UNITS             "no units"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns a bit mapped status word where each bit set (as defined below) 
		                       indicates a specific active warning:
		
		                           0       1       2       3       4       5       6       7    
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       |System |System | Laser | Laser | Laser | Laser | Input | Input |
		                       | Temp  | Temp  |Current|Current| Temp  | Temp  |  RF   |  RF   |
		                       | High  | Low   | High  |  Low  | High  | Low   | Level | Level |
		                       |       |       |       |       |       |       |  High |  Low  |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		
		                           8       9       10      11      12      13      14      15   
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       |Optical|Optical| TEC   |  AGC  |Key in |Remote |       |       |
		                       | Power | Power |Current| Unlock| Off   | Off   |       |       |
		                       |  Out  |  Out  | High  |       |Position Mode  |       |       |
		                       |  High |  Low  |       |       |       | Set   |       |       |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                      "
		    ::= { lte153Laser 37 }
		    
		unitStatusHistory     OBJECT-TYPE
		    SYNTAX            BITS 
		                      {
		                       systemTempHigh(0),
		                       systemTempLow(1),
		                       laserCurrentHigh(2),
		                       laserCurrentLow(3),
		                       laserTempHigh(4),
		                       laserTempLow(5),
		                       inputRFHigh(6),
		                       inputRFLow(7),
		                       opticalPowerHigh(8),
		                       opticalPowerLow(9),
		                       tecCurrentHigh(10),
		                       agcUnlock(11),
		                       keyInOffPosition(12),
		                       remoteOffModeSet(13)
		                      }
		    UNITS             "no units"
		    MAX-ACCESS        read-write
		    STATUS            current
		    DESCRIPTION       "Returns a bit mapped status word where each bit set (as defined below) 
		                       indicates a an alarm had occurred since the last power up or clear:
		
		                           0       1       2       3       4       5       6       7    
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       |System |System | Laser | Laser | Laser | Laser | Input | Input |
		                       | Temp  | Temp  |Current|Current| Temp  | Temp  |  RF   |  RF   |
		                       | High  | Low   | High  |  Low  | High  | Low   | Level | Level |
		                       |       |       |       |       |       |       |  High |  Low  |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		
		                           8       9       10      11      12      13      14      15   
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       |Optical|Optical| TEC   |  AGC  |Key in |Remote |       |       |
		                       | Power | Power |Current| Unlock| Off   | Off   |       |       |
		                       |  Out  |  Out  | High  |       |Position Mode  |       |       |
		                       |  High |  Low  |       |       |       | Set   |       |       |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		
		                       Clear status history by writing a value of 0.
		                      "
		    ::= { lte153Laser 38 }
		  
		miscStatusEnable      OBJECT-TYPE
		    SYNTAX            BITS 
		                      {
		                       sbs2GHzPowerHigh(0),
		                       sbs2GHzPowerLow(1),
		                       sbs6GHzPowerHigh(2),
		                       sbs6GHzPowerLow(3),
		                       system5VPowerHigh(4),
		                       system5VPowerLow(5),
		                       system12VPowerHigh(6),
		                       system12VPowerLow(7),
		                       system24VPowerHigh(8),
		                       system24VPowerLow(9),
		                       systemM5VPowerHigh(10),
		                       systemM5VPowerLow(11),
		                       systemM12VPowerHigh(12),
		                       systemM12VPowerLow(13),
		                       communicationFailure(14),
		                       powerSupplyAFailure(16),
		                       powerSupplyBFailure(17),
		                       coolingFanAFailure(18),
		                       coolingFanBFailure(19)
		                      }
		    UNITS             "no units"
		    MAX-ACCESS        read-write
		    STATUS            current
		    DESCRIPTION       "Indicates the miscellaneous status alarm enable. This
		                       value is bit encoded therefore it is capable
		                       of indicating multiple alarm enable conditions. 
		                       The bits are defined as follows:
		
		                           0       1       2       3       4       5       6       7    
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       | 2 GHz | 2 GHz | 6 GHz | 6 GHz |System |System |System |System |
		                       | SBS   | SBS   | SBS   | SBS   | +5V   | +5V   | +12V  | +12V  |
		                       | Power | Power | Power | Power | Power | Power | Power | Power |
		                       | High  | Low   | High  | Low   | High  | Low   | High  | Low   |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		
		                           8       9       10      11      12      13      14      15   
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       |System |System |System |System |System |System | Comm  |       |
		                       | +24V  | +24V  | -5V   | -5V   | -12V  | -12V  |Failure|       |
		                       | Power | Power | Power | Power | Power | Power |       |       |
		                       | High  | Low   | High  | Low   | High  | Low   |       |       |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		
		                           16      17      18      19      20      21      22      23   
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       | Power | Power |Cooling|Cooling|       |       |       |       |
		                       | Supply| Supply|  Fan  |  Fan  |       |       |       |       |
		                       |   A   |   B   |   A   |   B   |       |       |       |       |
		                       |Failure|Failure|Failure|Failure|       |       |       |       |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                      "
		    ::= { lte153Laser 39 }
		 
		miscStatusMajor       OBJECT-TYPE
		    SYNTAX            BITS 
		                      {
		                       sbs2GHzPowerHigh(0),
		                       sbs2GHzPowerLow(1),
		                       sbs6GHzPowerHigh(2),
		                       sbs6GHzPowerLow(3),
		                       system5VPowerHigh(4),
		                       system5VPowerLow(5),
		                       system12VPowerHigh(6),
		                       system12VPowerLow(7),
		                       system24VPowerHigh(8),
		                       system24VPowerLow(9),
		                       systemM5VPowerHigh(10),
		                       systemM5VPowerLow(11),
		                       systemM12VPowerHigh(12),
		                       systemM12VPowerLow(13),
		                       communicationFailure(14),
		                       powerSupplyAFailure(16),
		                       powerSupplyBFailure(17),
		                       coolingFanAFailure(18),
		                       coolingFanBFailure(19)
		                      }
		    UNITS             "no units"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns a bit mapped status word where each bit set (as defined below) 
		                       indicates a specific active alarm:
		
		                           0       1       2       3       4       5       6       7    
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       | 2 GHz | 2 GHz | 6 GHz | 6 GHz |System |System |System |System |
		                       | SBS   | SBS   | SBS   | SBS   | +5V   | +5V   | +12V  | +12V  |
		                       | Power | Power | Power | Power | Power | Power | Power | Power |
		                       | High  | Low   | High  | Low   | High  | Low   | High  | Low   |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		
		                           8       9       10      11      12      13      14      15   
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       |System |System |System |System |System |System | Comm  |Power  |
		                       | +24V  | +24V  | -5V   | -5V   | -12V  | -12V  |Failure|Supply |
		                       | Power | Power | Power | Power | Power | Power |       |Failure|
		                       | High  | Low   | High  | Low   | High  | Low   |       |       |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		
		                           16      17      18      19      20      21      22      23   
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       | Power | Power |Cooling|Cooling|       |       |       |       |
		                       | Supply| Supply|  Fan  |  Fan  |       |       |       |       |
		                       |   A   |   B   |   A   |   B   |       |       |       |       |
		                       |Failure|Failure|Failure|Failure|       |       |       |       |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                      "
		    ::= { lte153Laser 40 }
		   
		miscStatusMinor       OBJECT-TYPE
		    SYNTAX            BITS 
		                      {
		                       sbs2GHzPowerHigh(0),
		                       sbs2GHzPowerLow(1),
		                       sbs6GHzPowerHigh(2),
		                       sbs6GHzPowerLow(3),
		                       system5VPowerHigh(4),
		                       system5VPowerLow(5),
		                       system12VPowerHigh(6),
		                       system12VPowerLow(7),
		                       system24VPowerHigh(8),
		                       system24VPowerLow(9),
		                       systemM5VPowerHigh(10),
		                       systemM5VPowerLow(11),
		                       systemM12VPowerHigh(12),
		                       systemM12VPowerLow(13),
		                       communicationFailure(14),
		                       powerSupplyAFailure(16),
		                       powerSupplyBFailure(17),
		                       coolingFanAFailure(18),
		                       coolingFanBFailure(19)
		                      }
		    UNITS             "no units"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns a bit mapped status word where each bit set (as defined below) 
		                       indicates a specific active warning:
		
		                           0       1       2       3       4       5       6       7    
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       | 2 GHz | 2 GHz | 6 GHz | 6 GHz |System |System |System |System |
		                       | SBS   | SBS   | SBS   | SBS   | +5V   | +5V   | +12V  | +12V  |
		                       | Power | Power | Power | Power | Power | Power | Power | Power |
		                       | High  | Low   | High  | Low   | High  | Low   | High  | Low   |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		
		                           8       9       10      11      12      13      14      15   
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       |System |System |System |System |System |System | Comm  |Power  |
		                       | +24V  | +24V  | -5V   | -5V   | -12V  | -12V  |Failure|Supply |
		                       | Power | Power | Power | Power | Power | Power |       |Failure|
		                       | High  | Low   | High  | Low   | High  | Low   |       |       |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		
		                           16      17      18      19      20      21      22      23   
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       | Power | Power |Cooling|Cooling|       |       |       |       |
		                       | Supply| Supply|  Fan  |  Fan  |       |       |       |       |
		                       |   A   |   B   |   A   |   B   |       |       |       |       |
		                       |Failure|Failure|Failure|Failure|       |       |       |       |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                      "
		    ::= { lte153Laser 41 }
		    
		miscStatusHistory     OBJECT-TYPE
		    SYNTAX            BITS 
		                      {
		                       sbs2GHzPowerHigh(0),
		                       sbs2GHzPowerLow(1),
		                       sbs6GHzPowerHigh(2),
		                       sbs6GHzPowerLow(3),
		                       system5VPowerHigh(4),
		                       system5VPowerLow(5),
		                       system12VPowerHigh(6),
		                       system12VPowerLow(7),
		                       system24VPowerHigh(8),
		                       system24VPowerLow(9),
		                       systemM5VPowerHigh(10),
		                       systemM5VPowerLow(11),
		                       systemM12VPowerHigh(12),
		                       systemM12VPowerLow(13),
		                       communicationFailure(14),
		                       powerSupplyAFailure(16),
		                       powerSupplyBFailure(17),
		                       coolingFanAFailure(18),
		                       coolingFanBFailure(19)
		                      }
		    UNITS             "no units"
		    MAX-ACCESS        read-write
		    STATUS            current
		    DESCRIPTION       "Returns a bit mapped status word where each bit set (as defined below) 
		                       indicates a an alarm had occurred since the last power up or clear:
		
		                           0       1       2       3       4       5       6       7    
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       | 2 GHz | 2 GHz | 6 GHz | 6 GHz |System |System |System |System |
		                       | SBS   | SBS   | SBS   | SBS   | +5V   | +5V   | +12V  | +12V  |
		                       | Power | Power | Power | Power | Power | Power | Power | Power |
		                       | High  | Low   | High  | Low   | High  | Low   | High  | Low   |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		
		                           8       9       10      11      12      13      14      15   
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       |System |System |System |System |System |System | Comm  |Power  |
		                       | +24V  | +24V  | -5V   | -5V   | -12V  | -12V  |Failure|Supply |
		                       | Power | Power | Power | Power | Power | Power |       |Failure|
		                       | High  | Low   | High  | Low   | High  | Low   |       |       |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		
		                           16      17      18      19      20      21      22      23   
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		                       | Power | Power |Cooling|Cooling|       |       |       |       |
		                       | Supply| Supply|  Fan  |  Fan  |       |       |       |       |
		                       |   A   |   B   |   A   |   B   |       |       |       |       |
		                       |Failure|Failure|Failure|Failure|       |       |       |       |
		                       +-------+-------+-------+-------+-------+-------+-------+-------+
		
		                       Clear status history by writing a value of 0.
		                      "
		    ::= { lte153Laser 42 }
		  
		frontPanelLEDStatus   OBJECT-TYPE
		    SYNTAX            BITS 
		                      {
		                       laserOn(0),
		                       laserOff(1),
		                       statusOkay(2),
		                       majorAlarmActive(3),
		                       minorAlarmActive(4),
		                       laserOnRearPanel(5)
		                      }
		    UNITS             "no units"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns a bit mapped status word where each bit set (as defined below) 
		                       indicates a specific LED state:
		
		                           0       1       2       3       4       5
		                       +-------+-------+-------+-------+-------+-------+
		                       | Laser | Laser |Status |Status |Status |LaserOn|
		                       |  On   |  Off  | Okay  | Major | Minor | Rear  |
		                       |       |       |       | Alarm | Alarm | Panel |
		                       | Green |  Red  | Green |  Red  |  Red  | Green |
		                       +-------+-------+-------+-------+-------+-------+
		                      "
		    ::= { lte153Laser 43 }
		  
		upTime                OBJECT-TYPE
		    SYNTAX            TimeTicks
		    UNITS             "seconds"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the number of elapsed seconds since the last time the
		                       unit restarted." 
		    ::= { lte153Laser 44 }
		
		-----------------------------------------------------------------------
		-- BEGIN transmitter common events
		-----------------------------------------------------------------------
		transmitterNotificationPrefix    OBJECT IDENTIFIER ::= { lte153Laser 45 }
		transmitterCommonNotifications   OBJECT IDENTIFIER ::= { transmitterNotificationPrefix 0 }
		
		transmitterNoAlarmsPresent NOTIFICATION-TYPE
		--    OBJECTS      { }
		    STATUS       current
		    DESCRIPTION "No alarms are present."
		    ::= { transmitterCommonNotifications 0 }
		
		transmitterSystemTemperatureHigh NOTIFICATION-TYPE
		    OBJECTS      { unitStatus, systemTemp }
		    STATUS       current
		    DESCRIPTION "The system temperature has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 1 }
		
		transmitterSystemTemperatureLow NOTIFICATION-TYPE
		    OBJECTS      { unitStatus, systemTemp }
		    STATUS       current
		    DESCRIPTION "The system temperature has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 2 }
		
		transmitterLaserCurrentHigh NOTIFICATION-TYPE
		    OBJECTS      { unitStatus, laserCurrent }
		    STATUS       current
		    DESCRIPTION "The laser current has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 3 }
		
		transmitterLaserCurrentLow NOTIFICATION-TYPE
		    OBJECTS      { unitStatus, laserCurrent }
		    STATUS       current
		    DESCRIPTION "The laser current has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 4 }
		
		transmitterLaserTemperatureHigh NOTIFICATION-TYPE
		    OBJECTS      { unitStatus, laserTemperature }
		    STATUS       current
		    DESCRIPTION "The laser temperature has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 5 }
		
		transmitterLaserTemperatureLow NOTIFICATION-TYPE
		    OBJECTS      { unitStatus, LaserTemp }
		    STATUS       current
		    DESCRIPTION "The laser temperature has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 6 }
		
		transmitterInputRFLevelHigh NOTIFICATION-TYPE
		    OBJECTS      { unitStatus, inputRFLevel }
		    STATUS       current
		    DESCRIPTION "The input RF level has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 7 }
		
		transmitterInputRFLevelLow NOTIFICATION-TYPE
		    OBJECTS      { unitStatus, inputRFLevel }
		    STATUS       current
		    DESCRIPTION "The input RF level has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 8 }
		
		transmitterOpticalPowerOutputHigh NOTIFICATION-TYPE
		    OBJECTS      { unitStatus, opticalPowerOut1 }
		    STATUS       current
		    DESCRIPTION "The optical power output has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 9 }
		
		transmitterOpticalPowerOutputLow NOTIFICATION-TYPE
		    OBJECTS      { unitStatus, opticalPowerOut1 }
		    STATUS       current
		    DESCRIPTION "The optical power output has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 10 }
		
		transmitterTECCurrentHigh NOTIFICATION-TYPE
		    OBJECTS      { unitStatus, tecCurrent }
		    STATUS       current
		    DESCRIPTION "The thermoelectric cooler current has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 11 }
		
		transmitterAGCUnlocked NOTIFICATION-TYPE
		    OBJECTS      { unitStatus, compositeRFLevel }
		    STATUS       current
		    DESCRIPTION "The RF attenuator automatic gain control (AGC) is outside its normal operating range."
		    ::= { transmitterCommonNotifications 12 }
		
		transmitterKeySwitchOffPosition NOTIFICATION-TYPE
		    OBJECTS      { unitStatus, keyswitch }
		    STATUS       current
		    DESCRIPTION "The key switch is in the OFF position."
		    ::= { transmitterCommonNotifications 13 }
		
		transmitterRemoteLaserOffMode NOTIFICATION-TYPE
		    OBJECTS      { unitStatus, remoteControl }
		    STATUS       current
		    DESCRIPTION "The remote laser control is commanded to be in OFF mode."
		    ::= { transmitterCommonNotifications 14 }
		
		transmitter2GHzSBSPowerHigh NOTIFICATION-TYPE
		    OBJECTS      { miscStatus, sbs2GHzPower }
		    STATUS       current
		    DESCRIPTION "The 2GHz SBS output power has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 15 }
		
		transmitter2GHzSBSPowerLow NOTIFICATION-TYPE
		    OBJECTS      { miscStatus, sbs2GHzPower }
		    STATUS       current
		    DESCRIPTION "The 2GHz SBS output power has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 16 }
		
		transmitter6GHzSBSPowerHigh NOTIFICATION-TYPE
		    OBJECTS      { miscStatus, sbs6GHzPower }
		    STATUS       current
		    DESCRIPTION "The 6GHz SBS output power has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 17 }
		
		transmitter6GHzSBSPowerLow NOTIFICATION-TYPE
		    OBJECTS      { miscStatus, sbs6GHzPower }
		    STATUS       current
		    DESCRIPTION "The 6GHz SBS output power has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 18 }
		
		transmitterSystem5VPowerHigh NOTIFICATION-TYPE
		    OBJECTS      { miscStatus, monitor5v }
		    STATUS       current
		    DESCRIPTION "The system +5V power supply has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 19 }
		
		transmitterSystem5VPowerLow NOTIFICATION-TYPE
		    OBJECTS      { miscStatus, monitor5v }
		    STATUS       current
		    DESCRIPTION "The system +5V power supply has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 20 }
		
		transmitterSystem12VPowerHigh NOTIFICATION-TYPE
		    OBJECTS      { miscStatus, monitor12v }
		    STATUS       current
		    DESCRIPTION "The system +12V power supply has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 21 }
		
		transmitterSystem12VPowerLow NOTIFICATION-TYPE
		    OBJECTS      { miscStatus, monitor12v }
		    STATUS       current
		    DESCRIPTION "The system +12V power supply has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 22 }
		
		transmitterSystem24VPowerHigh NOTIFICATION-TYPE
		    OBJECTS      { miscStatus, monitor24v }
		    STATUS       current
		    DESCRIPTION "The system +24V power supply has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 23 }
		
		transmitterSystem24VPowerLow NOTIFICATION-TYPE
		    OBJECTS      { miscStatus, monitor24v }
		    STATUS       current
		    DESCRIPTION "The system +24V power supply has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 24 }
		
		transmitterSystemM5VPowerHigh NOTIFICATION-TYPE
		    OBJECTS      { miscStatus, monitorM5v }
		    STATUS       current
		    DESCRIPTION "The system -5V power supply has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 25 }
		
		transmitterSystemM5VPowerLow NOTIFICATION-TYPE
		    OBJECTS      { miscStatus, monitorM5v }
		    STATUS       current
		    DESCRIPTION "The system -5V power supply has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 26 }
		
		transmitterSystemM12VPowerHigh NOTIFICATION-TYPE
		    OBJECTS      { miscStatus, monitorM12v }
		    STATUS       current
		    DESCRIPTION "The system -12V power supply has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 27 }
		
		transmitterSystemM12VPowerLow NOTIFICATION-TYPE
		    OBJECTS      { miscStatus, monitorM12v }
		    STATUS       current
		    DESCRIPTION "The system -12V power supply has exceeded its normal operating value."
		    ::= { transmitterCommonNotifications 28 }
		
		transmitterCommunicationFailure NOTIFICATION-TYPE
		    OBJECTS      { miscStatus }
		    STATUS       current
		    DESCRIPTION "A failure was detected with the internal network communication interface."
		    ::= { transmitterCommonNotifications 29 }
		
		transmitterPowerSupplyAFailure NOTIFICATION-TYPE
		    OBJECTS      { miscStatus }
		    STATUS       current
		    DESCRIPTION "A failure was detected with power supply module A."
		    ::= { transmitterCommonNotifications 30 }
		
		transmitterPowerSupplyBFailure NOTIFICATION-TYPE
		    OBJECTS      { miscStatus }
		    STATUS       current
		    DESCRIPTION "A failure was detected with power supply module B."
		    ::= { transmitterCommonNotifications 31 }
		
		transmitterCoolingFanAFailure NOTIFICATION-TYPE
		    OBJECTS      { miscStatus }
		    STATUS       current
		    DESCRIPTION "A failure was detected with cooling fan A."
		    ::= { transmitterCommonNotifications 32 }
		
		transmitterCoolingFanBFailure NOTIFICATION-TYPE
		    OBJECTS      { miscStatus }
		    STATUS       current
		    DESCRIPTION "A failure was detected with cooling fan B."
		    ::= { transmitterCommonNotifications 33 }
		
		-----------------------------------------------------------------------
		-- END transmitter common events
		-----------------------------------------------------------------------
		
		
-- Product Information Tree
		-- 1.3.6.1.4.1.11606.7.2
		lte153PowerSupply OBJECT IDENTIFIER ::= { lte153 2 }              

        powerSupplyType       OBJECT-TYPE
   			SYNTAX            INTEGER { undefined(0),single5V(1),dualRedundant5V(2),single5-12-24V(3),dualRedundant5-12-24V(4) }
    		UNITS             "no units"
    		MAX-ACCESS        read-only
    		STATUS            current
    		DESCRIPTION       "Returns the installed power supply type.
                       
                       single5V(1)              - Single AC/DC power supply with rated output of 5V at 100W.
                       dualRedundant5V(2)       - Dual, redundant AC/DC power supplies with rated output of 
                                                     5V at 100W each.
                       single5-12-24V(3)        - Single AC/DC power supply with rated outputs of 5V, +/-12V
                                                     and 24V at 100W total.
                       dualRedundant5-12-24V(4) - Dual, redundant AC/DC power supplies with rated outputs of
                                                     5V, +/-12V and 24V at 100W total.
                      " 
   			::= { lte153PowerSupply 1 }
 
		powerSupplyTemp       OBJECT-TYPE
    		SYNTAX            Integer32(-500..1200)
    		UNITS             "tenth of a Celsius degree(C)"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the power supply regulator temperature."
		    ::= { lte153PowerSupply 2 }

		powerSupplyStatusA    OBJECT-TYPE
		    SYNTAX            INTEGER { undefined(0),nominal(1),failure(2),notInstalled(3) }
		    UNITS             "no units"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the operating status of power supply A."
		    ::= { lte153PowerSupply 3 }

		powerSupplyStatusB    OBJECT-TYPE
		    SYNTAX            INTEGER { undefined(0),nominal(1),failure(2),notInstalled(3) }
		    UNITS             "no units"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the operating status of power supply B."
		    ::= { lte153PowerSupply 4 }
	
		coolingFanA           OBJECT-TYPE
		    SYNTAX            INTEGER { undefined(0),nominal(1),failure(2),notInstalled(3) }
		    UNITS             "no units"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the operating status of chassis cooling fan A."
		    ::= { lte153PowerSupply 5 }
	
		coolingFanB           OBJECT-TYPE
		    SYNTAX            INTEGER { undefined(0),nominal(1),failure(2),notInstalled(3) }
		    UNITS             "no units"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the operating status of chassis cooling fan B."
		    ::= { lte153PowerSupply 6 }
	
		upTime                OBJECT-TYPE
		    SYNTAX            TimeTicks
		    UNITS             "seconds"
		    MAX-ACCESS        read-only
		    STATUS            current
		    DESCRIPTION       "Returns the number of elapsed seconds since the last time the
		                       unit restarted." 
		    ::= { lte153PowerSupply 7 }
		
		-----------------------------------------------------------------------
		-- BEGIN power supply events
		-----------------------------------------------------------------------
		powerSupplyNotificationPrefix    OBJECT IDENTIFIER ::= { lte153PowerSupply 8 }
		powerSupplyNotifications   OBJECT IDENTIFIER ::= { powerSupplyNotificationPrefix 0 }
		
		powerSupplyNoAlarmsPresent NOTIFICATION-TYPE
		--    OBJECTS      { }
		    STATUS       current
		    DESCRIPTION  "No alarms are present."
		    ::= { powerSupplyNotifications 0 }
		
		powerSupplyPowerSupplyFailureA NOTIFICATION-TYPE
		    OBJECTS      { powerSupplyStatusA }
		    STATUS       current
		    DESCRIPTION  "A failure was detected with power supply module A."
		    ::= { powerSupplyNotifications 1 }
		
		powerSupplyPowerSupplyFailureB NOTIFICATION-TYPE
		    OBJECTS      { powerSupplyStatusB }
		    STATUS       current
		    DESCRIPTION  "A failure was detected with power supply module B."
		    ::= { powerSupplyNotifications 2 }
		
		powerSupplyCoolingFanFailureA NOTIFICATION-TYPE
		    OBJECTS      { coolingFanStatusA }
		    STATUS       current
		    DESCRIPTION  "A failure was detected with chassis cooling fan A."
		    ::= { powerSupplyNotifications 3 }
		
		powerSupplyCoolingFanFailureB NOTIFICATION-TYPE
		    OBJECTS      { coolingFanStatusB }
		    STATUS       current
		    DESCRIPTION  "A failure was detected with chassis cooling fan B."
		    ::= { powerSupplyNotifications 4 }
		
		-----------------------------------------------------------------------
		-- END power supply events
		-----------------------------------------------------------------------
	
	
	
	
--
-- Trap definitions
--
	
-- **************************************************************************
-- ***************** TRAP FOR OCMF, OCMR, OCMC ******************************
-- **************************************************************************
-- **************************************************************************
-- pbnTrap : The PBN enterprise trap URGENT Alarm
		module15 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 5 Alarm notification"
			::=  15

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module16 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 6 Alarm notification"
			::=  16

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module17 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 7 Alarm notification"
			::=  17

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module18 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 8 Alarm notification"
			::=  18

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module19 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 9 notification"
			::=  19

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module25 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 5 notification"
			::=  25

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module26 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 6 notification"
			::=  26

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module27 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 7 notification"
			::=  27

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap URGENT Alarm
		module28 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 8 notification"
			::=  28

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module29 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 9 notification"
			::=  29

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module35 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 5 notification"
			::=  35

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module36 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 6 notification"
			::=  36

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module37 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 7 notification"
			::=  37

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module38 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 8 notification"
			::=  38

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module39 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 9 notification"
			::=  39

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module45 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 4 Param 5 notification"
			::=  45

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module46 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 4 Param 6 notification"
			::=  46

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module47 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 4 Param 7 notification"
			::=  47

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module48 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 4 Param 8 notification"
			::=  48

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module49 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 4 Param 9 notification"
			::=  49

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module110 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 10 notification"
			::=  110

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module111 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 11 notification"
			::=  111

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module112 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 12 notification"
			::=  112

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module113 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 13 notification"
			::=  113

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module114 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 14 notification"
			::=  114

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap URGENT Alarm
		module115 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 15 notification"
			::=  115

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module116 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 16 notification"
			::=  116

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module117 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 17 notification"
			::=  117

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module118 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 18 notification"
			::=  118

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module119 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 19 notification"
			::=  119

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module120 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 20 notification"
			::=  120

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module121 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 21 notification"
			::=  121

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module122 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 22 notification"
			::=  122

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module123 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 23 notification"
			::=  123

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module124 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 24 notification"
			::=  124

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module125 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 25 notification"
			::=  125

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module126 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 26 notification"
			::=  126

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module127 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 27 notification"
			::=  127

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module128 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 28 notification"
			::=  128

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module129 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 29 notification"
			::=  129

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module130 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 30 notification"
			::=  130

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module131 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 1 Param 31 notification"
			::=  131

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module210 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 10 notification"
			::=  210

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module211 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 11 notification"
			::=  211

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module212 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 12 notification"
			::=  212

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module213 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 13 notification"
			::=  213

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module214 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 14 notification"
			::=  214

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module215 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 15 notification"
			::=  215

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module216 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 16 notification"
			::=  216

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module217 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 17 notification"
			::=  217

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap URGENT Alarm
		module218 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 18 notification"
			::=  218

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module219 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 19 Alarm notification"
			::=  219

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module220 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 20 notification"
			::=  220

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module221 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 21 notification"
			::=  221

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module222 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 22 notification"
			::=  222

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module223 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 23 notification"
			::=  223

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module224 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 24 notification"
			::=  224

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module225 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 25 notification"
			::=  225

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module226 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 26 notification"
			::=  226

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module227 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 27 notification"
			::=  227

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module228 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 28 notification"
			::=  228

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module229 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 29 notification"
			::=  229

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module230 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 30 notification"
			::=  230

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module231 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 2 Param 31 notification"
			::=  231

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module310 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 10 notification"
			::=  310

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap URGENT Alarm
		module311 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 11 notification"
			::=  311

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module312 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 12 notification"
			::=  312

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module313 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 13 notification"
			::=  313

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module314 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 14 notification"
			::=  314

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module315 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 15 notification"
			::=  315

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module316 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 16 notification"
			::=  316

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module317 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 17 notification"
			::=  317

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module318 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 18 notification"
			::=  318

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module319 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 19 notification"
			::=  319

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module320 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 20 notification"
			::=  320

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap URGENT Alarm
		module321 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 21 notification"
			::=  321

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap URGENT Alarm
		module322 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 22 notification"
			::=  322

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap URGENT Alarm
		module323 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 23 notification"
			::=  323

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap URGENT Alarm
		module324 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 24 notification"
			::=  324

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap URGENT Alarm
		module325 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 25 notification"
			::=  325

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap URGENT Alarm
		module326 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 26 notification"
			::=  326

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap URGENT Alarm
		module327 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 27 notification"
			::=  327

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap URGENT Alarm
		module328 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 28 notification"
			::=  328

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap URGENT Alarm
		module329 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 29 notification"
			::=  329

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap URGENT Alarm
		module330 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 30 notification"
			::=  330

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap URGENT Alarm
		module331 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 3 Param 31 notification"
			::=  331

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module410 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 4 Param 10 notification"
			::=  410

-- **************************************************************************
-- pbnTrap : The PBN enterprise trap NONURGENT Alarm
		module411 TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { ocmSlot, ocmParam, ocmParamString, ocmParamStatus }
			DESCRIPTION 
				"PBN Module 4 Param 11 notification"
			::=  411

-- **************************************************************************
-- CPON-100 Contact Input Trap
		cpon100ContactInput TRAP-TYPE 
			ENTERPRISE cpon100Trap
			VARIABLES { cpon100TrapMsg, cpon100MACAddr, cpon100TrapStatus, contactInput }
			DESCRIPTION 
				"CPON-100 Tamper alarm"
			::=  412

-- **************************************************************************
-- CPON-100 Sensing Input Trap
		cpon100sensingInput TRAP-TYPE 
			ENTERPRISE cpon100Trap
			VARIABLES { cpon100TrapMsg, cpon100MACAddr, cpon100TrapStatus, sensingInput }
			DESCRIPTION 
				"CPON-100 Battery alarm"
			::=  413

-- **************************************************************************
-- CPON-100 CATV Status Trap
		cpon100CATVAlarm TRAP-TYPE 
			ENTERPRISE cpon100Trap
			VARIABLES { catvStatus, cpon100TrapMsg, cpon100MACAddr, cpon100TrapStatus }
			DESCRIPTION 
				"CPON-100 CATV alarm"
			::=  414

		mauStatus5VTrap TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { mauProductMAC, mauTrapMessageDescr, mauStatus5V }
			::=  415

		mauStatus12VTrap TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { mauProductMAC, mauTrapMessageDescr, mauStatus12V }
			::=  416

		mauStatus24VTrap TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { mauProductMAC, mauTrapMessageDescr, mauStatus24V }
			::=  417

		mauStatusInputOpticalPowerTrap TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { mauProductMAC, mauTrapMessageDescr, mauStatusInputOpticalPower }
			::=  418

		mauStatusOutputOpticalPowerTrap TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { mauProductMAC, mauTrapMessageDescr, mauStatusOutputOpticalPower }
			::=  419

		mauStatusRFOutputTrap TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { mauProductMAC, mauTrapMessageDescr, mauStatusRFOutputPower }
			::=  420

		mauStatusTemperatureTrap TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { mauProductMAC, mauTrapMessageDescr, mauStatusTemperature }
			::=  421

		mauStatusLidTrap TRAP-TYPE 
			ENTERPRISE pbnTrap
			VARIABLES { mauProductMAC, mauTrapMessageDescr, mauStatusLid }
			::=  422

	
	END

--
-- PBN-MIB.mib
--