1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
|
-- File Name : PBI-MGSIGNALCHARACTERISTICS-MIB
-- Date : Thu Sep 21 14:37:54 CST 2006
-- Author : AdventNet Agent Toolkit Java Edition - MIB Editor 6
PBI-MGSIGNALCHARACTERISTICS-MIB DEFINITIONS ::= BEGIN
IMPORTS
RowStatus, DisplayString
FROM SNMPv2-TC
DisplayString
FROM RFC1213-MIB
mg
FROM PBI-MAIN-MIB
MODULE-IDENTITY, enterprises, OBJECT-TYPE, Integer32
FROM SNMPv2-SMI;
mgSignalCharacteristics MODULE-IDENTITY
LAST-UPDATED "200609210924Z"
ORGANIZATION "Organization"
CONTACT-INFO "Contact-info"
DESCRIPTION "Description"
REVISION "200609210924Z"
DESCRIPTION ""
::= { mg 2 }
tsOutTable OBJECT-TYPE
SYNTAX SEQUENCE OF TsOutEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " "
::= { mgSignalCharacteristics 1 }
mgPATTable OBJECT-TYPE
SYNTAX SEQUENCE OF MgPATEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "PSI/SI information relating to the PAT, reference ISO/IEC 13818-1 "
::= { mgSignalCharacteristics 2 }
mgPMTTable OBJECT-TYPE
SYNTAX SEQUENCE OF MgPMTEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "PSI/SI information relating to the PMT"
::= { mgSignalCharacteristics 3 }
mgNITTable OBJECT-TYPE
SYNTAX SEQUENCE OF MgNITEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "PSI/SI information relating to the NIT"
::= { mgSignalCharacteristics 4 }
mgSDTTable OBJECT-TYPE
SYNTAX SEQUENCE OF MgSDTEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "PSI/SI information relating to the SDT, reference DVB 300-468"
::= { mgSignalCharacteristics 5 }
mgFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF MgFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Description"
::= { mgSignalCharacteristics 6 }
mgCATTable OBJECT-TYPE
SYNTAX SEQUENCE OF MgCATEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "PSI/SI information relating to the CAT, reference ISO/IEC 13818-1 "
::= { mgSignalCharacteristics 7 }
tsInput OBJECT IDENTIFIER
::= { mgSignalCharacteristics 8 }
mgBATTable OBJECT-TYPE
SYNTAX SEQUENCE OF MgBATEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " PSI/SI information relating to the BAT, reference ISO/IEC 13818-1 "
::= { mgSignalCharacteristics 9 }
tsOutEntry OBJECT-TYPE
SYNTAX TsOutEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " Row Description "
INDEX { channelOutput }
::= { tsOutTable 1 }
TsOutEntry ::= SEQUENCE {
channelOutput INTEGER,
bitRate INTEGER,
packetSize INTEGER,
transportStreamID INTEGER,
otiginalNetworkID INTEGER,
networkID INTEGER,
bitrateThreshosdPercent INTEGER,
outValidBitRate INTEGER
}
channelOutput OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "output channel number"
::= { tsOutEntry 1 }
bitRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Transport stream output size, 3000EC: from 0 to 16Mpbs; 3000MX:from 0 to 100Mpbs; 3000TM: from 0 to 50Mpbs"
::= { tsOutEntry 2 }
packetSize OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Packet length, option: 188 or 204"
::= { tsOutEntry 3 }
transportStreamID OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The transport stream ID for this transport stream as read from the PAT, its value range: reference ISO/IEC 13818-1"
::= { tsOutEntry 4 }
otiginalNetworkID OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The original network ID for this transport stream as read from the NIT, its value range: reference DVB 300-468"
::= { tsOutEntry 5 }
networkID OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The network ID for this transport stream as read from the NIT, its value range: reference DVB 300-468"
::= { tsOutEntry 6 }
bitrateThreshosdPercent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "ts overflow percent value(0 - 100)"
::= { tsOutEntry 7 }
outValidBitRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "transport stream out valid bit rate"
::= { tsOutEntry 8 }
mgPATEntry OBJECT-TYPE
SYNTAX MgPATEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Row Description"
INDEX { channelInputPAT }
::= { mgPATTable 1 }
MgPATEntry ::= SEQUENCE {
channelInputPAT INTEGER,
patSection DisplayString
}
channelInputPAT OBJECT-TYPE
SYNTAX INTEGER ( -2147483648 .. 2147483647 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The physical input on which this transport stream appears"
::= { mgPATEntry 1 }
patSection OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The transport stream Relating to the PAT seciton, reference ISO/IEC 13818-1 "
::= { mgPATEntry 2 }
mgPMTEntry OBJECT-TYPE
SYNTAX MgPMTEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Row Description"
INDEX { channelInputPMT }
::= { mgPMTTable 1 }
MgPMTEntry ::= SEQUENCE {
channelInputPMT INTEGER,
pmtProgramNumber INTEGER,
pmtPID INTEGER,
pmtSection DisplayString
}
channelInputPMT OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The physical input on which this transport stream appears"
::= { mgPMTEntry 1 }
pmtProgramNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The PMT program number as read from PMT,reference ISO/IEC 13818-1"
::= { mgPMTEntry 2 }
pmtPID OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The PMT PID as read from PMT,reference ISO/IEC 13818-1"
::= { mgPMTEntry 3 }
pmtSection OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The transport stream Relating to the PMT seciton, reference ISO/IEC 13818-1"
::= { mgPMTEntry 4 }
mgNITEntry OBJECT-TYPE
SYNTAX MgNITEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Row Description"
INDEX { channelInputNIT }
::= { mgNITTable 1 }
MgNITEntry ::= SEQUENCE {
channelInputNIT INTEGER,
networkType INTEGER,
nitActualSection DisplayString,
nitOhtersSection DisplayString
}
channelInputNIT OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The physical input on which this transport stream appears"
::= { mgNITEntry 1 }
networkType OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The network type include two types: actual NIT and others NIT, reference DVB 300-468"
::= { mgNITEntry 2 }
nitActualSection OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Relating to the Actual section, its table ID is 0x40 in NIT,reference DVB 300-468"
::= { mgNITEntry 3 }
nitOhtersSection OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Relating to the others section , its table ID is 0x41 in NIT,reference DVB 300-468"
::= { mgNITEntry 4 }
mgSDTEntry OBJECT-TYPE
SYNTAX MgSDTEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Row Description"
INDEX { channelInputSDT }
::= { mgSDTTable 1 }
MgSDTEntry ::= SEQUENCE {
channelInputSDT INTEGER,
sdtSection DisplayString
}
channelInputSDT OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The physical input on which this transport stream appears"
::= { mgSDTEntry 1 }
sdtSection OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The transport stream relating to SDT seciton, reference DVB 300-468"
::= { mgSDTEntry 2 }
mgFilterEntry OBJECT-TYPE
SYNTAX MgFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Row Description"
INDEX { channelInputFilter }
::= { mgFilterTable 1 }
MgFilterEntry ::= SEQUENCE {
channelInputFilter INTEGER,
oldPID DisplayString,
newPID DisplayString,
oldProgramNumber DisplayString,
newProgramNumber DisplayString
}
channelInputFilter OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The physical input on which this transport stream appears"
::= { mgFilterEntry 1 }
oldPID OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The old PID will be filtered output"
::= { mgFilterEntry 2 }
newPID OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The new PID is bulit according to old PID"
::= { mgFilterEntry 3 }
oldProgramNumber OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The old program number,they come from PAT and will be filtered output"
::= { mgFilterEntry 4 }
newProgramNumber OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The new program number, they are bulit and will be made a new PAT"
::= { mgFilterEntry 5 }
mgCATEntry OBJECT-TYPE
SYNTAX MgCATEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Row Description"
INDEX { channelInputCAT }
::= { mgCATTable 1 }
MgCATEntry ::= SEQUENCE {
channelInputCAT INTEGER,
catSection DisplayString
}
channelInputCAT OBJECT-TYPE
SYNTAX INTEGER ( -2147483648 .. 2147483647 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The physical input on which this transport stream appears"
::= { mgCATEntry 1 }
catSection OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The transport stream Relating to the CAT seciton, reference ISO/IEC 13818-1 "
::= { mgCATEntry 2 }
channelInput OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "channel number of input"
::= { tsInput 1 }
stateLock OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "0xFFFF is lock, other is unlock"
::= { tsInput 2 }
tsIdPreference OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "transport stream identifier"
::= { tsInput 3 }
mgBATEntry OBJECT-TYPE
SYNTAX MgBATEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Row Description"
INDEX { channelBAT }
::= { mgBATTable 1 }
MgBATEntry ::= SEQUENCE {
channelBAT INTEGER,
batSection DisplayString
}
channelBAT OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "specify channel of get BAT "
::= { mgBATEntry 1 }
batSection OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The transport stream Relating to the BAT seciton, reference ISO/IEC 13818-1 "
::= { mgBATEntry 2 }
END
|