summaryrefslogtreecommitdiff
path: root/MIBS/omnitron/OMNITRON-TC-MIB
blob: 2d0548bf16a94a306ecee58009a24ee7407c26ac (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
OMNITRON-TC-MIB DEFINITIONS ::= BEGIN

-- *****************************************************************************
-- TEXTUAL-CONVENTIONs MIB for Omnitron Systems Technology Enterprise MIBs
-- *****************************************************************************

IMPORTS
    MODULE-IDENTITY, Integer32, Unsigned32, Counter64, enterprises
        FROM SNMPv2-SMI         -- RFC-2578
    TEXTUAL-CONVENTION
        FROM SNMPv2-TC;         -- RFC 2579


ostOmnitronTcMib MODULE-IDENTITY
    LAST-UPDATED "201505131200Z"     -- May 13, 2015
    ORGANIZATION "Omnitron Systems Technology, Inc."
    CONTACT-INFO "Omnitron Systems Technology, Inc.
                  38 Tesla
                  Irvine, CA 92618-4670
                  USA

             Tel: (949) 250 6510
             Fax: (949) 250 6514
          E-mail: info@omnitron-systems.com
   International:  949 250 6510

                  Technical Support and Customer Service
             Tel: (800) 675 8410
          E-mail: support@omnitron-systems.com
   International:  949 250 6510"

    DESCRIPTION
            "Omnitron TC MIB for use with v5.2 iConverter Management Modules
             and NetOutlook

             Copyright 2015 Omnitron Systems Technology, Inc.
             All rights reserved
            "

    REVISION    "201505131200Z"     -- May 13, 2015
    DESCRIPTION "Added OstIpv6Addr, OstIpAddr
                "

    REVISION    "201501211200Z"     -- January 21, 2015
    DESCRIPTION "Initial version of v5.2 MIB.
                   Added OstAccessibiltyType from the OMNITRON-ACL-MIB
                "
    ::= { enterprises 7342 11 }

omnitron                OBJECT IDENTIFIER ::= { enterprises 7342 }
icAgent                 OBJECT IDENTIFIER ::= { omnitron 1 }


-- *****************************************************************************
-- Textual Conventions (TC)
-- *****************************************************************************
-- TC definitions are placed in alphabetical order

OstAccessibiltyType ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "Accessibilty type enumeration.

         deny(1)       Access to the module is not allowed
         permit(2)     Access to the module is allowed
        "
    SYNTAX      INTEGER {
                  deny        (1),
                  permit      (2)
                }


OstClassOfService ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS      current
    DESCRIPTION
       "Class of service setting.  0=discard, 1=lowest class, 4=highest class"
    SYNTAX      Unsigned32 (0..4)


OstClockFreq ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d-2"
    STATUS      current
    DESCRIPTION
        "Clock frequency in hundreths of MHz."
    SYNTAX      Unsigned32


OstCosL2cpDstAddr ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS      current
    DESCRIPTION
        "L2CP destination address enumeration.

         Index | Destination Address | Name
         ------+--------------------+---------
             1 | 01-80-C2-00-00-00   | RSTP
             2 | 01-80-C2-00-00-01   | Pause
             3 | 01-80-C2-00-00-02   | LACP
             4 | 01-80-C2-00-00-02   | Marker
             5 | 01-80-C2-00-00-02   | Link OAM
             6 | 01-80-C2-00-00-02   |
             7 | 01-80-C2-00-00-03   | 802.1x
             8 | 01-80-C2-00-00-04   | IEEE MAC
             9 | 01-80-C2-00-00-05   |
            10 | 01-80-C2-00-00-06   |
            11 | 01-80-C2-00-00-07   | E-LMI
            12 | 01-80-C2-00-00-08   | Pr Bridge
            13 | 01-80-C2-00-00-09   |
            14 | 01-80-C2-00-00-0A   |
            15 | 01-80-C2-00-00-0B   |
            16 | 01-80-C2-00-00-0C   |
            17 | 01-80-C2-00-00-0D   | GVRP
            18 | 01-80-C2-00-00-0E   | LLDP
            19 | 01-80-C2-00-00-0F   |
            20 | 01-80-C2-00-00-20   | GARP
        "
    SYNTAX      Unsigned32 (1..20)


OstCosNameString ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "A class of service name."
    SYNTAX      OCTET STRING (SIZE(1..45))


OstCosNameStringOrNone ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "A class of service name or an empty string."
    SYNTAX      OCTET STRING (SIZE(0..45))


OstCosTrustType ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "CoS trust type enumeration.

         Green traffic is marked with low drop precedence and yellow
         traffic is marked with high drop precedence.

         cosTrust(1)        Trust frame. The frames priority
                            determines the egress class.

         cosUsePri(2)       Use the priority ostCosPriority for the
                            frame. The frame will egress with ostCosPriority
                            priority and ostCosPrirority determines the
                            egress class.

         cosUseClass(3)     Use the class ostCosClass for the frame.
                            The frame will egress with the frames
                            priority and the ostCosClass egress class.

         cosUsePriClass(4)  Use the priority ostCosPriority and class
                            ostCosClass for the frame. The frames will
                            egress with ostCosPri and ostCosClass egress
                            class.

         cosGreenYellow(5)  Use ostCosGreenPriority and ostCosGreenClass for
                            green traffic. Use ostCosYellowPriority and
                            ostCosYellowClass for yellow traffic.
        "
    SYNTAX      INTEGER {
                  cosTrust          (1),
                  cosUsePri         (2),
                  cosUseClass       (3),
                  cosUsePriClass    (4),
                  cosGreenYellow    (5)
                }


OstEgressSchedulingProfileIndexType ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS      current
    DESCRIPTION
       "A value that uniquely identifies an Egress Scheduling Profile.

        The valid values are 1 to X, where X is the maximum supported profile.
        The maximum value for X for the GM4 is 4.
       "
    SYNTAX      Unsigned32 (1..8)


OstEgressQueueIndexType ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS      current
    DESCRIPTION
       "A value that uniquely identifies an Egress Queue.

        The valid values are 1 to X, where X is the maximum supported profile.
        The maximum value for X for the GM4 is 4.
       "
    SYNTAX      Unsigned32 (1..8)


OstElpsProtectType ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "A value that represents the ELPS protection type.  The value can be one
        of the following:

        e1plus1UniNoAps(1)   1 unidirectional without APS communication
        e1plus1UniAps(2)     1 unidirectional switching with APS communication
        e1plus1BiAps(3)      1 bidirectional w/APS communication
        e1to1(4)             1:1 bidirectional w/APS communication
        notAvailable(5)      Protect Type is unknown or not available, value returned
                                 for status read, not allowed to write
       "
    SYNTAX      INTEGER {
                  e1plus1UniNoAps (1),
                  e1plus1UniAps   (2),
                  e1plus1BiAps    (3),
                  e1to1           (4),
                  notAvailable    (5)
                }


OstElpsRequestStates ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "A value that represents the current request/state of either the local or
        remote (partner) ELPS instance.  The value can be one of the following:

        noRequest(0)             No Request (NR), lowest priority
        doNotRevert(1)           Do Not Revert (DNR)
        revertRequest(2)         Revert request (RR)
        exercise(4)              Exercise APS protocol (EXER)
        waitToRestore(5)         Wait to restore (WTR)
        manualSwitchWorking(6)   Manual swtich to working (MS-W)
        manualSwitch(7)          Manual switch (MS)
        signalDegrade(9)         Signal degrade (SD)
        signalFailWorking(11)    Signal fail for working (SF)
        forcedSwitch(13)         Forced switch (FS)
        signalFailProtection(14) Signal fail for protection (SF-P)
        lockoutProtection(15)    Lock of protection (LO), highest priority
        notAvailable(16)         Status is unknown or not available, value returned
                                 for status read, not allowed to write
       "
    SYNTAX      INTEGER {
                  noRequest            (0),
                  doNotRevert          (1),
                  revertRequest        (2),
                  exercise             (4),
                  waitToRestore        (5),
                  manualSwitchWorking  (6),
                  manualSwitch         (7),
                  signalDegrade        (9),
                  signalFailWorking    (11),
                  forcedSwitch         (13),
                  signalFailProtection (14),
                  lockoutProtection    (15),
                  notAvailable         (16)
                }


OstElpsSignalStates ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "A value that represents the requested or bridged signal for either
        the local or remote (partner) ELPS instance.  The value can be one of
        the following:

        nullSignal(0)            Null signal. This indicates the signal that
                                 the near-end requests be carried over the
                                 protection path
        normalSignal(1)          Normal traffic signal. This indicates the
                                 signal that is bridged onto the protection
                                 path.
        notAvailable(2)          Protect Type is unknown or not available, value
                                 returned for status read, not allowed to write
       "
    SYNTAX      INTEGER {
                  nullSignal           (0),
                  normalSignal         (1),
                  notAvailable         (2)
                }


OstErpsLinkState ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "A value that represents the current port link state. This is a
        function that indicates whether the current port is linked.
        The value can be one of the following:

        na(0)                    Not Applicable, port state is unknown
        up(1)                    Port is linked and capable of passing traffic
        down(2)                  Port is not linked and is not capable of
                                 passing traffic
       "
    SYNTAX      INTEGER {
                  na(0),
                  up(1),
                  down(2)
                }


OstErpsPortState ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "A value that represents the current forwarding state of the port.
        The value can be one of the following:

        na(0)                    Not Applicable, port state is unknown
        forward(1)               Port is in the forwarding state
        blocked(2)               Port is in the blocked state
       "
    SYNTAX      INTEGER {
                  na(0),
                  forward(1),
                  blocked(2)
                }


OstErpsPortType ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "A value that represents the Ring Port type. The value can be one of the
        following:

        rp0(1)                   Ring Port 0
        rp1(2)                   Ring Port 1
       "
    SYNTAX      INTEGER {
                  rp0(1),
                  rp1(2)
                }


OstErpsRingStates ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "A value that represents the current request/state of either the local or
        remote (partner) ERPS instance.  The value can be one of the following:

        noRequest(0)             No Request (NR), local, lowest priority
        rapsNr(1)                Ring APS (R-APS) No Request (NR), remote
        rapsNrRb(2)              Ring APS (R-APS) No Request (NR), RPL Blocked (RB), remote
        wtbRunning(3)            Wait to Block (WTB) running, local
        wtbExpires(4)            Wait to Block (WTB) expires, local
        wtrRunning(5)            Wait to Restore (WTR) running, local
        wtrExpires(6)            Wait to Restore (WTR) expires, local
        manualSwitch(7)          Manual Switch (MS), local
        rapsManualSwitch(8)      Ring APS (R-APS) Manual Switch (MS), remote
        rapsSignalFail(9)        Ring APS (R-APS) Signal Fail (SF), remote
        localClearSignalFail(10) Local clear Signal Fail (SF), local
        localSignalFail(11)      Local Signal Fail (SF), local
        rapsForcedSwitch(12)     Ring APS (R-APS) Forced Switch (FS), remote
        forcedSwtich(13)         Forced Switch (FS), local
        clear(14)                Clear, local
       "
    REFERENCE
       "[ITU-T G.8032] Table 10-1"
    SYNTAX      INTEGER {
                  noRequest            (0),
                  rapsNr               (1),
                  rapsNrRb             (2),
                  wtbRunning           (3),
                  wtbExpires           (4),
                  wtrRunning           (5),
                  wtrExpires           (6),
                  manualSwitch         (7),
                  rapsManualSwitch     (8),
                  rapsSignalFail       (9),
                  localClearSignalFail (10),
                  localSignalFail      (11),
                  rapsForcedSwitch     (12),
                  forcedSwtich         (13),
                  clear                (14)
                }


OstErpsRingStatus ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "A value that represents the current ring status. This is state machine node
        state value for the ERPS instance.  The value can be one of the
        following:

        initializing(1)          State machine initialization
        idle(2)                  Idle State (A)
        protection(3)            Protection (B)
        manualSwitch(4)          Manual Switch (C)
        forcedSwitch(5)          Forced Switch (D)
        pending(6)               Pending (E)
       "
    REFERENCE
       "[ITU-T G.8032] Table 10-2"
    SYNTAX      INTEGER {
                  initializing         (1),
                  idle                 (2),
                  protection           (3),
                  manualSwitch         (4),
                  forcedSwitch         (5),
                  pending              (6)
                }


OstErrorString ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "The SNMP error string for further definition of a SNMP error."
    SYNTAX      OCTET STRING (SIZE(0..255))


OstEvcNameString ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "An EVC name."
    SYNTAX      OCTET STRING (SIZE(1..45))


OstEvcNameStringOrNone ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "An EVC name or an empty string."
    SYNTAX      OCTET STRING (SIZE(0..45))


OstFileNameString ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "A internal file name."
    SYNTAX      OCTET STRING (SIZE(1..45))


OstFingerprintString ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "The fingerprint value for SSH protocol."
    SYNTAX      OCTET STRING (SIZE(1..64))


OstFloatValue ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "Floating point data type as represented in an octet string.
        Legal values and precision are indicated by the appropriate object.
        Only numbers and the decimal place are legal digit values.

        Example values:
           1000
           1500.05
           1545.25
       "
    SYNTAX      OCTET STRING (SIZE(0..20))


OstFrameCount64 ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS      current
    DESCRIPTION
        "Frame counter value."
    SYNTAX      Counter64


OstFrameSizeList ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "
        Denotes a list of one or more frame sizes.

        1. Frame sizes have a value from 64 to 10240 bytes for the GM3, GM4,
           and GM4-PoE. Frame sizes have a value from 64 to 10240 bytes for
           the XM5.

        2. Individual frame sizes are included when separated by a comma ','.

        3. A range of frame sizes is included when separated by '..'.

        4. A range of sizes ending in a colon and a value, i.e. start..end:value,
           is the frame increment size for the next iteration (min value is 4)

        5. Ranges must be organized min size to max size, i.e. min..max

        6. Individual sizes can be mixed in any order

        Example values:
          64
          64..1024:64
          64,128,256,512,1024,1280,1518,10000
       "
    SYNTAX      OCTET STRING (SIZE(1..255))


OstIndexIntegerNextFree ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS      current
    DESCRIPTION
       "An integer which may be used as a new index in a table.

        The special value of 0 indicates that no more new entries can
        be created in the relevant table.

        When a MIB is used for configuration, an object with this
        SYNTAX always contains a legal value (if non-zero) for an
        index that is not currently used in the relevant table. The
        Command Generator (Network Management Application) reads this
        variable and uses the (non-zero) value read when creating a
        new row with an SNMP SET.  When the SET is performed, the
        Command Responder (agent) MUST determine whether the value is
        indeed still unused; Two Network Management Applications may
        attempt to create a row (configuration entry) simultaneously
        and use the same value. If it is currently unused, the SET
        succeeds and the Command Responder (agent) changes the value
        of this object, according to an implementation-specific
        algorithm.  If the value is in use, however, the SET fails.
        The Network Management Application MUST then re-read this
        variable to obtain a new usable value.

        An OBJECT-TYPE definition using this SYNTAX MUST specify the
        relevant table for which the object is providing this
        functionality.
       "
    SYNTAX      Unsigned32 (0..16)


OstIpPriorityList ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "Selects IP priority values.  Valid values are from 0 to 63.
        Format:
            X       selects a single PCP priority value
            X..Y    selects a range of PCP priority values, X to Y
            X,Y     selects PCP priority values seperated by a comma
        Example values:
         0
         2..5
         0,2..5
       "
    SYNTAX      OCTET STRING (SIZE(0..14))


OstIpv6Addr ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "2x:2x:2x:2x:2x:2x:2x:2x"
    STATUS      current
    DESCRIPTION
       "This data type is used to model the IPv6 address. This is a
        binary string of up to 8 octets in network byte-order.
       "
    SYNTAX      OCTET STRING (SIZE(16..16))


OstIpAddr ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "This data type is used to model both IPv4 and IPv6 addresses. It
        is a hexadecimcal octet string with separators between number groups:
        either '.' for IPv4 or ':' for IPv6. The IP type is derived based upon
        the format of the string. Valid IP addreses:
            '192.168.1.220'
            'fe80:0000:0:0:1234:5678:abcd:efff'

       "
    SYNTAX      OCTET STRING (SIZE(0..39))


OstMhfCreation ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "Indicates if the Management Entity can create MHFs.

        The valid values are:
                ostMHFdefault(2) MHFs can be created on this VID on any
                        Bridge port through which this VID can pass.
                ostMHFexplicit(3) MHFs can be created for this VID only on
                        Bridge ports through which this VID can
                        pass, and only if a MEP is created at some
                        lower MD Level.
       "
    SYNTAX      INTEGER {
                  ostMHFdefault (1),
                  ostMHFexplicit (2)
                }


OstMipdMethodOfCreation ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "Indicates the method of how this Mip table entry was created
        The valid values are:
                ostExplicit(1) indicates the Mip was created explicitly
                        through a command.
                ostImplicitMa(2) indicates the Mip was created implicitly
                        through the MA command.
                ostImplicitMde(3) indicates the Mip was created implicitly
                        through the CFM default Md table.
                ostExplicitImplicitMa(4) indicates the Mip was created both
                        implicitly and explicitly through the MA command.
        "
    SYNTAX      INTEGER {
                ostExplicit(1),
                ostImplicitMa(2),
                ostImplicitMde(3),
                ostExplicitImplicitMa(4)
                }


OstModeType ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The module Mode Type as AP, SP or neither.

         normal(1)   Not specifically AP or SP
         ap(2)       Access Provider
         sp(3)       Service Provider
        "
    SYNTAX INTEGER {
        normal (1),
        ap    (2),
        sp     (3)
    }


OstModuleSingleIndex ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS      current
    DESCRIPTION
       "A value that uniquely identifies the chassis and slot in which the module is located.
       Base 10 Format: CCSS where
            CC is the chassis index, 1 to 99
            SS is the slot index, 1 to 99"
    SYNTAX      Unsigned32 (101..9999)


OstPcpPriorityList ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "Selects PCP priority values.  Valid values are from 0 to 7.
        Format:
            X       selects a single PCP priority value
            X..Y    selects a range of PCP priority values, X to Y
            X,Y     selects PCP priority values seperated by a comma
        Example values:
         0
         2..5
         0,2..5
       "
    SYNTAX      OCTET STRING (SIZE(0..14))


OstPortClockType ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "A value that indicates the TDM port recovery state/mode.
       "
    SYNTAX      INTEGER {
        adaptiveIdle(1),
        adaptiveAcqu(2),
        adaptiveTrk1(3),
        adaptiveTrk2(4),
        holdOver(5),
        coax(6),
        internal(7),
        line(8)
    }


OstPortList ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "Denotes a list of one or more ports, separated by comma characters, in the
        form of an ASCII string, which is case insensitive.

        Port  Description
        ----  ------------------
         1    Port 1
         2    Port 2
         3    Port 3
         4    Port 4
         5    Port 5
         6    Port 6
         7    Port 7
         8    Port 8
         9    Port 9
         10   Port 10
         11   Port 11
         12   Port 12
         13   Port 13
         14   Port 14
         15   Port 15
         16   Port 16
         17   Port 17
         a    backplane port A
         b    backplane port B
         mgt1 management port 1
         mgt2 management port 2
         all  includes all ports

        Example: '1,2,a,mgt1'
        "
    SYNTAX      OCTET STRING


OstPortNumber ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS      current
    DESCRIPTION
       "This object selects the port number for the specific test
        instance that is configured.

        This value is dependent upon actual product accessed. The port number
        for a specific port can be determined by selecting the module type
        and then the port that is accessed. A value of '0' indicates that
        no port is defined.

        Module Type        P1   P2   P3   P4   P5   BP A  BP B  Mgt1  Mgt2
        -----------------  ---  ---  ---  ---  ---  ----  ----  ----  ----
        3-port plug-in     1    2    3    n/a  n/a  4     5     6     7
        3-port standalone  1    2    3    n/a  n/a  n/a   n/a   6     7
        2-port plug-in     1    2    n/a  n/a  n/a  3     4     5     6
        2-port standalone  1    2    n/a  n/a  n/a  n/a   n/a   5     6
        4-port             1    2    3    4    n/a  5     6     n/a   n/a
        5-port             1    2    3    4    5    n/a   n/a   6     7

        For the 7 port module: Port 1 - Port 7 are ports 1 - 7 are the front
        facing ports, port 8 is the dedicated management port, port 9 is Mgt1
        and port 10 is Mgt2.

        For the 16 port module: Port 1 - Port 16 are the customer facing
        ports, port 17 is the dedicated management port, port 18 is Mgt1 and
        port 19 is Mgt2.

        Other values are undefined.
      "
    SYNTAX      Unsigned32 (0..99)


OstPortSingleIndex ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS      current
    DESCRIPTION
       "A value that uniquely identifies a module port, and the chassis and slot in
       which the module is located.
       Base 10 Format: CCSSPP where
            CC is the chassis index, 1 to 99
            SS is the slot index, 1 to 99
            PP is the port index, 1 to 99"
    SYNTAX      Unsigned32 (10101..999999)


OstPriority ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS      current
    DESCRIPTION
       "Priority setting."
    SYNTAX      Unsigned32 (0..7)


OstProbeNameString ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "An EVC name."
    SYNTAX      OCTET STRING (SIZE(1..45))


OstProfileNameString ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "A test profile name."
    SYNTAX      OCTET STRING (SIZE(1..45))


OstTestResultType ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "A value that indicates the result of a test.  The value can be one of
        the following:

        pass(1)              Indicates the test has passed successfully
        fail(2)              Indicates the test has failed
        oversubscribe(3)     Indicates the test failed due to oversubscription
                             of a resource
       "
    SYNTAX      INTEGER {
                  pass            (1),
                  fail            (2),
                  oversubscribe   (3)
                }


OstTestStatusType ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "A value that indicates the status of the current test instance.  The
        value can be one of the following:

        testNotStarted(1)    Current test instance has not started yet,
                             not fully configured, or waiting for loop-up
        testInProcess(2)     Current test instance is currently running
        testStopped(3)       Current test instance has been stopped after running
                             for a period of time
        testCompleted(4)     Current test instance has completed
        testInitializing(5)  Current test is the process of starting, used to
                             restart a test in process, completed, or stopped
       "
    SYNTAX      INTEGER {
                  testNotStarted  (1),
                  testInProcess   (2),
                  testStopped     (3),
                  testCompleted   (4),
                  testInitializing(5)
                }


OstUnsigned64 ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS      current
    DESCRIPTION
       "A non-negative 64-bit bit integer, without counter semantics, between 0
        and 2^64-1 inclusive (0 to 18446744073709551615 decimal).

        It can have a MAX-ACCESS of read-only or read-write.

        SYNTAX is Counter64 for the encoding rules only.
       "
    SYNTAX      Counter64


OstUserNameString ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "A string that is used to identify a specific user."
    SYNTAX      OCTET STRING (SIZE(1..32))


OstVlanId ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS      current
    DESCRIPTION
        "The VLAN-ID that uniquely identifies a VLAN.  This
        is the 12-bit VLAN-ID used in the VLAN Tag header."
    SYNTAX      Integer32 (0..4095)


OstVlanIdList ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS      current
    DESCRIPTION
       "Denotes a list of one or more VLAN IDs.
       VLAN IDs have a value of 0 to 4095.
       Individual VLAN IDs are included when separated by a comma ','.
       A range of VLAN IDs is included when separated by '..'.
       An asterisk indicates untagged data.
       'rest' selects remaining VLAN IDs.
       'all' selects all VLAN IDs.
       Example values:
         100,110
         100..110
         100,110,200..210
         100,110,200..210,500..510
       "
    SYNTAX      OCTET STRING (SIZE(0..110))


END