1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
|
RS-232-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, transmission,
Counter32, Integer32
FROM SNMPv2-SMI
InterfaceIndex
FROM IF-MIB
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF;
rs232 MODULE-IDENTITY
LAST-UPDATED "9405261700Z"
ORGANIZATION "IETF Character MIB Working Group"
CONTACT-INFO
" Bob Stewart
Postal: Xyplex, Inc.
295 Foster Street
Littleton, MA 01460
Tel: 508-952-4816
Fax: 508-952-4887
E-mail: rlstewart@eng.xyplex.com"
DESCRIPTION
"The MIB module for RS-232-like hardware devices."
::= { transmission 33 }
-- Generic RS-232-like information
rs232Number OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ports (regardless of their current
state) in the RS-232-like general port table."
::= { rs232 1 }
-- RS-232-like General Port Table
rs232PortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232PortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of port entries. The number of entries is
given by the value of rs232Number."
::= { rs232 2 }
rs232PortEntry OBJECT-TYPE
SYNTAX Rs232PortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status and parameter values for a port."
INDEX { rs232PortIndex }
::= { rs232PortTable 1 }
Rs232PortEntry ::=
SEQUENCE {
rs232PortIndex
InterfaceIndex,
rs232PortType
INTEGER,
rs232PortInSigNumber
Integer32,
rs232PortOutSigNumber
Integer32,
rs232PortInSpeed
Integer32,
rs232PortOutSpeed
Integer32,
rs232PortInFlowType
INTEGER,
rs232PortOutFlowType
INTEGER
}
rs232PortIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ifIndex for the port. By convention
and if possible, hardware port numbers map directly
to external connectors. The value for each port must
remain constant at least from one re-initialization
of the network management agent to the next."
::= { rs232PortEntry 1 }
rs232PortType OBJECT-TYPE
SYNTAX INTEGER { other(1), rs232(2), rs422(3),
rs423(4), v35(5), x21(6) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port's hardware type."
::= { rs232PortEntry 2 }
rs232PortInSigNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of input signals for the port in the
input signal table (rs232PortInSigTable). The table
contains entries only for those signals the software
can detect and that are useful to observe."
::= { rs232PortEntry 3 }
rs232PortOutSigNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of output signals for the port in the
output signal table (rs232PortOutSigTable). The
table contains entries only for those signals the
software can assert and that are useful to observe."
::= { rs232PortEntry 4 }
rs232PortInSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port's input speed in bits per second. Note that
non-standard values, such as 9612, are probably not allowed
on most implementations."
::= { rs232PortEntry 5 }
rs232PortOutSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port's output speed in bits per second. Note that
non-standard values, such as 9612, are probably not allowed
on most implementations."
::= { rs232PortEntry 6 }
rs232PortInFlowType OBJECT-TYPE
SYNTAX INTEGER { none(1), ctsRts(2), dsrDtr(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port's type of input flow control. 'none'
indicates no flow control at this level.
'ctsRts' and 'dsrDtr' indicate use of the indicated
hardware signals."
::= { rs232PortEntry 7 }
rs232PortOutFlowType OBJECT-TYPE
SYNTAX INTEGER { none(1), ctsRts(2), dsrDtr(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port's type of output flow control. 'none'
indicates no flow control at this level.
'ctsRts' and 'dsrDtr' indicate use of the indicated
hardware signals."
::= { rs232PortEntry 8 }
-- RS-232-like Asynchronous Port Table
rs232AsyncPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232AsyncPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of asynchronous port entries. Entries need
not exist for synchronous ports."
::= { rs232 3 }
rs232AsyncPortEntry OBJECT-TYPE
SYNTAX Rs232AsyncPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status and parameter values for an asynchronous
port."
INDEX { rs232AsyncPortIndex }
::= { rs232AsyncPortTable 1 }
Rs232AsyncPortEntry ::=
SEQUENCE {
rs232AsyncPortIndex
InterfaceIndex,
rs232AsyncPortBits
INTEGER,
rs232AsyncPortStopBits
INTEGER,
rs232AsyncPortParity
INTEGER,
rs232AsyncPortAutobaud
INTEGER,
rs232AsyncPortParityErrs
Counter32,
rs232AsyncPortFramingErrs
Counter32,
rs232AsyncPortOverrunErrs
Counter32
}
rs232AsyncPortIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value for each port. Its value is the
same as rs232PortIndex for the port."
::= { rs232AsyncPortEntry 1 }
rs232AsyncPortBits OBJECT-TYPE
SYNTAX INTEGER (5..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port's number of bits in a character."
::= { rs232AsyncPortEntry 2 }
rs232AsyncPortStopBits OBJECT-TYPE
SYNTAX INTEGER { one(1), two(2),
oneAndHalf(3), dynamic(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port's number of stop bits."
::= { rs232AsyncPortEntry 3 }
rs232AsyncPortParity OBJECT-TYPE
SYNTAX INTEGER { none(1), odd(2), even(3),
mark(4), space(5) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port's sense of a character parity bit."
::= { rs232AsyncPortEntry 4 }
rs232AsyncPortAutobaud OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A control for the port's ability to automatically
sense input speed.
When rs232PortAutoBaud is 'enabled', a port may
autobaud to values different from the set values for
speed, parity, and character size. As a result a
network management system may temporarily observe
values different from what was previously set."
::= { rs232AsyncPortEntry 5 }
rs232AsyncPortParityErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of characters with a parity error,
input from the port since system re-initialization
and while the port state was 'up' or 'test'."
::= { rs232AsyncPortEntry 6 }
rs232AsyncPortFramingErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of characters with a framing error,
input from the port since system re-initialization
and while the port state was 'up' or 'test'."
::= { rs232AsyncPortEntry 7 }
rs232AsyncPortOverrunErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of characters with an overrun error,
input from the port since system re-initialization
and while the port state was 'up' or 'test'."
::= { rs232AsyncPortEntry 8 }
-- RS-232-like Synchronous Port Table
rs232SyncPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232SyncPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of asynchronous port entries. Entries need
not exist for synchronous ports."
::= { rs232 4 }
rs232SyncPortEntry OBJECT-TYPE
SYNTAX Rs232SyncPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status and parameter values for a synchronous
port."
INDEX { rs232SyncPortIndex }
::= { rs232SyncPortTable 1 }
Rs232SyncPortEntry ::=
SEQUENCE {
rs232SyncPortIndex
InterfaceIndex,
rs232SyncPortClockSource
INTEGER,
rs232SyncPortFrameCheckErrs
Counter32,
rs232SyncPortTransmitUnderrunErrs
Counter32,
rs232SyncPortReceiveOverrunErrs
Counter32,
rs232SyncPortInterruptedFrames
Counter32,
rs232SyncPortAbortedFrames
Counter32,
rs232SyncPortRole
INTEGER,
rs232SyncPortEncoding
INTEGER,
rs232SyncPortRTSControl
INTEGER,
rs232SyncPortRTSCTSDelay
Integer32,
rs232SyncPortMode
INTEGER,
rs232SyncPortIdlePattern
INTEGER,
rs232SyncPortMinFlags
Integer32
}
rs232SyncPortIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value for each port. Its value is the
same as rs232PortIndex for the port."
::= { rs232SyncPortEntry 1 }
rs232SyncPortClockSource OBJECT-TYPE
SYNTAX INTEGER { internal(1), external(2), split(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Source of the port's bit rate clock. 'split' means
the tranmit clock is internal and the receive clock
is external."
::= { rs232SyncPortEntry 2 }
rs232SyncPortFrameCheckErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of frames with an invalid frame check
sequence, input from the port since system
re-initialization and while the port state was 'up'
or 'test'."
::= { rs232SyncPortEntry 3 }
rs232SyncPortTransmitUnderrunErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of frames that failed to be
transmitted on the port since system
re-initialization and while the port state was 'up'
or 'test' because data was not available to the
transmitter in time."
::= { rs232SyncPortEntry 4 }
rs232SyncPortReceiveOverrunErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of frames that failed to be received
on the port since system re-initialization and while
the port state was 'up' or 'test' because the
receiver did not accept the data in time."
::= { rs232SyncPortEntry 5 }
rs232SyncPortInterruptedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of frames that failed to be received
or transmitted on the port due to loss of modem
signals since system re-initialization and while the
port state was 'up' or 'test'."
::= { rs232SyncPortEntry 6 }
rs232SyncPortAbortedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames aborted on the port due to
receiving an abort sequence since system
re-initialization and while the port state was 'up'
or 'test'."
::= { rs232SyncPortEntry 7 }
rs232SyncPortRole OBJECT-TYPE
SYNTAX INTEGER { dte(1), dce(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The role the device is playing that is using this port.
dte means the device is performing the role of
data terminal equipment
dce means the device is performing the role of
data circuit-terminating equipment."
DEFVAL { dce }
::= { rs232SyncPortEntry 8 }
rs232SyncPortEncoding OBJECT-TYPE
SYNTAX INTEGER { nrz(1), nrzi(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The bit stream encoding technique that is in effect
for this port.
nrz for Non-Return to Zero encoding
nrzi for Non-Return to Zero Inverted encoding."
DEFVAL { nrz }
::= { rs232SyncPortEntry 9 }
rs232SyncPortRTSControl OBJECT-TYPE
SYNTAX INTEGER { controlled(1), constant(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The method used to control the Request To Send (RTS)
signal.
controlled when the DTE is asserts RTS each time
data needs to be transmitted and drops
RTS at some point after data
transmission begins.
If rs232SyncPortRole is 'dte', the
RTS is an output signal. The device
will issue a RTS and wait for a CTS
from the DCE before starting to
transmit.
If rs232SyncPortRole is 'dce', the
RTS is an input signal. The device
will issue a CTS only after having
received RTS and waiting the
rs232SyncPortRTSCTSDelay interval.
constant when the DTE constantly asserts RTS."
DEFVAL { constant }
::= { rs232SyncPortEntry 10 }
rs232SyncPortRTSCTSDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval (in milliseconds) that the DCE must wait
after it sees RTS asserted before asserting CTS. This
object exists in support of older synchronous devices
that cannot recognize CTS within a certain interval
after it asserts RTS."
DEFVAL { 0 }
::= { rs232SyncPortEntry 11 }
rs232SyncPortMode OBJECT-TYPE
SYNTAX INTEGER { fdx(1), hdx(2), simplex-receive(3),
simplex-send(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mode of operation of the port with respect to the
direction and simultaneity of data transfer.
fdx when frames on the data link can be
transmitted and received at the same
time
hdx when frames can either be received
from the data link or transmitted
onto the data link but not at the
same time.
simplex-receive when frames can only be received on
this data link.
simplex-send when frames can only be sent on this
data link."
DEFVAL { fdx }
::= { rs232SyncPortEntry 12 }
rs232SyncPortIdlePattern OBJECT-TYPE
SYNTAX INTEGER { mark(1), space(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The bit pattern used to indicate an idle line."
DEFVAL { space }
::= { rs232SyncPortEntry 13 }
rs232SyncPortMinFlags OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The minimum number of flag patterns this port needs in
order to recognize the end of one frame and the start
of the next. Plausible values are 1 and 2."
DEFVAL { 2 }
::= { rs232SyncPortEntry 14 }
-- Input Signal Table
rs232InSigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232InSigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of port input control signal entries
implemented and visible to the software on the port,
and useful to monitor."
::= { rs232 5 }
rs232InSigEntry OBJECT-TYPE
SYNTAX Rs232InSigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Input control signal status for a hardware port."
INDEX { rs232InSigPortIndex, rs232InSigName }
::= { rs232InSigTable 1 }
Rs232InSigEntry ::=
SEQUENCE {
rs232InSigPortIndex
InterfaceIndex,
rs232InSigName
INTEGER,
rs232InSigState
INTEGER,
rs232InSigChanges
Counter32
}
rs232InSigPortIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of rs232PortIndex for the port to which
this entry belongs."
::= { rs232InSigEntry 1 }
rs232InSigName OBJECT-TYPE
SYNTAX INTEGER { rts(1), cts(2), dsr(3), dtr(4), ri(5),
dcd(6), sq(7), srs(8), srts(9),
scts(10), sdcd(11) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identification of a hardware signal, as follows:
rts Request to Send
cts Clear to Send
dsr Data Set Ready
dtr Data Terminal Ready
ri Ring Indicator
dcd Received Line Signal Detector
sq Signal Quality Detector
srs Data Signaling Rate Selector
srts Secondary Request to Send
scts Secondary Clear to Send
sdcd Secondary Received Line Signal Detector
"
REFERENCE
"EIA Standard RS-232-C, August 1969."
::= { rs232InSigEntry 2 }
rs232InSigState OBJECT-TYPE
SYNTAX INTEGER { none(1), on(2), off(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal state."
::= { rs232InSigEntry 3 }
rs232InSigChanges OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the signal has changed from
'on' to 'off' or from 'off' to 'on'."
::= { rs232InSigEntry 4 }
-- Output Signal Table
rs232OutSigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232OutSigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of port output control signal entries
implemented and visible to the software on the port,
and useful to monitor."
::= { rs232 6 }
rs232OutSigEntry OBJECT-TYPE
SYNTAX Rs232OutSigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Output control signal status for a hardware port."
INDEX { rs232OutSigPortIndex, rs232OutSigName }
::= { rs232OutSigTable 1 }
Rs232OutSigEntry ::=
SEQUENCE {
rs232OutSigPortIndex
InterfaceIndex,
rs232OutSigName
INTEGER,
rs232OutSigState
INTEGER,
rs232OutSigChanges
Counter32
}
rs232OutSigPortIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of rs232PortIndex for the port to which
this entry belongs."
::= { rs232OutSigEntry 1 }
rs232OutSigName OBJECT-TYPE
SYNTAX INTEGER { rts(1), cts(2), dsr(3), dtr(4), ri(5),
dcd(6), sq(7), srs(8), srts(9),
scts(10), sdcd(11) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identification of a hardware signal, as follows:
rts Request to Send
cts Clear to Send
dsr Data Set Ready
dtr Data Terminal Ready
ri Ring Indicator
dcd Received Line Signal Detector
sq Signal Quality Detector
srs Data Signaling Rate Selector
srts Secondary Request to Send
scts Secondary Clear to Send
sdcd Secondary Received Line Signal Detector
"
REFERENCE
"EIA Standard RS-232-C, August 1969."
::= { rs232OutSigEntry 2 }
rs232OutSigState OBJECT-TYPE
SYNTAX INTEGER { none(1), on(2), off(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal state."
::= { rs232OutSigEntry 3 }
rs232OutSigChanges OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the signal has changed from
'on' to 'off' or from 'off' to 'on'."
::= { rs232OutSigEntry 4 }
-- conformance information
rs232Conformance OBJECT IDENTIFIER ::= { rs232 7 }
rs232Groups OBJECT IDENTIFIER ::= { rs232Conformance 1 }
rs232Compliances OBJECT IDENTIFIER ::= { rs232Conformance 2 }
-- compliance statements
rs232Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMPv2 entities
which have RS-232-like hardware interfaces."
MODULE -- this module
MANDATORY-GROUPS { rs232Group }
GROUP rs232AsyncGroup
DESCRIPTION
"The Asynch group is mandatory only for those
SNMPv2 entities which have asynchronous
interfaces Rs-232-like."
GROUP rs232SyncGroup
DESCRIPTION
"The Synch group is mandatory only for those
SNMPv2 entities which have synchronous
interfaces Rs-232-like."
::= { rs232Compliances 1 }
-- units of conformance
rs232Group OBJECT-GROUP
OBJECTS { rs232Number, rs232PortIndex, rs232PortType,
rs232PortInSigNumber, rs232PortOutSigNumber,
rs232PortInSpeed, rs232PortOutSpeed,
rs232PortInFlowType, rs232PortOutFlowType,
rs232InSigPortIndex, rs232InSigName,
rs232InSigState, rs232InSigChanges,
rs232OutSigPortIndex, rs232OutSigName,
rs232OutSigState, rs232OutSigChanges }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to all RS-232-like interfaces."
::= { rs232Groups 1 }
rs232AsyncGroup OBJECT-GROUP
OBJECTS { rs232AsyncPortIndex, rs232AsyncPortBits,
rs232AsyncPortStopBits, rs232AsyncPortParity,
rs232AsyncPortAutobaud, rs232AsyncPortParityErrs,
rs232AsyncPortFramingErrs, rs232AsyncPortOverrunErrs }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to asynchronous RS-232-like interfaces."
::= { rs232Groups 2 }
rs232SyncGroup OBJECT-GROUP
OBJECTS { rs232SyncPortIndex, rs232SyncPortClockSource,
rs232SyncPortFrameCheckErrs,
rs232SyncPortTransmitUnderrunErrs,
rs232SyncPortReceiveOverrunErrs,
rs232SyncPortInterruptedFrames,
rs232SyncPortAbortedFrames }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to synchronous RS-232-like interfaces."
::= { rs232Groups 3 }
rs232SyncSDLCGroup OBJECT-GROUP
OBJECTS { rs232SyncPortRole,
rs232SyncPortEncoding,
rs232SyncPortRTSControl,
rs232SyncPortRTSCTSDelay,
rs232SyncPortMode,
rs232SyncPortIdlePattern,
rs232SyncPortMinFlags }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to synchronous RS-232-like interfaces
running SDLC."
::= { rs232Groups 4 }
END
|