summaryrefslogtreecommitdiff
path: root/MIBS/netgear/NETGEAR-BOXSERVICES-PRIVATE-MIB
blob: c95964c098e19a1b83a3c1bc6e1cdd8f99656488 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
-- Box Services MIB overview:
-- Box Services MIB falls under ng7000managedswitch MIB node of the private subtree.

NETGEAR-BOXSERVICES-PRIVATE-MIB DEFINITIONS ::= BEGIN

-- Netgear Inc NETGEAR Box Services MIB
-- Copyright Netgear Inc(2004-2008) All rights reserved.

-- This SNMP Management Information Specification
-- embodies Netgear Inc's confidential and proprietary
-- intellectual property.  Netgear Inc retains all title
-- and ownership in the Specification including any revisions.

-- This Specification is supplied "AS IS", Netgear Inc
-- makes no warranty, either expressed or implied,
-- as to the use, operation, condition, or performance of the
-- Specification.


IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
    Unsigned32, Integer32               FROM SNMPv2-SMI
    TEXTUAL-CONVENTION		             	FROM SNMPv2-TC
    DisplayString		                    FROM RFC1213-MIB
    ng7000managedswitch                            FROM NETGEAR-REF-MIB;

    fastPathBoxServices MODULE-IDENTITY
           LAST-UPDATED "201101260000Z" -- 26 Jan 2011 12:00:00 GMT
           ORGANIZATION "Netgear Inc"
           CONTACT-INFO ""
 
     DESCRIPTION
          "The Netgear Private MIB for NETGEAR Box Services Feature."

      -- Revision history.
      REVISION
          "201101260000Z" -- 26 Jan 2011 12:00:00 GMT
      DESCRIPTION
          "Postal address updated."
      REVISION
          "200802220000Z" -- 22 Feb 2008 12:00:00 GMT
      DESCRIPTION
          "Netgear branding related changes."

      ::= { ng7000managedswitch 43 }

BoxsTemperatureStatus ::= TEXTUAL-CONVENTION
   STATUS  current
   DESCRIPTION
           "The temperature state"
   SYNTAX      INTEGER {
                        low(0),
                        normal(1),
                        warning(2),
                        critical(3),
                        shutdown(4),
                        notpresent(5),
                        notoperational(6)
                       }

--**************************************************************************************
--    boxServicesGroup
--
--    This group provides configuration and status of the Box Services
--    feature.  
--
--**************************************************************************************

	boxServicesGroup               OBJECT IDENTIFIER ::= { fastPathBoxServices 1 }
  
   --**************************************************************************************
   -- Some scalars
   
    boxServicesNormalTempRangeMin OBJECT-TYPE
      SYNTAX     Integer32 (-100..100)
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
       " Lower boundary of normal temperature range."
      DEFVAL { 0 }
    ::= { boxServicesGroup 1 }

    boxServicesNormalTempRangeMax OBJECT-TYPE
      SYNTAX     Integer32 (-100..100)
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
       " Upper boundary of normal temperature range."
      DEFVAL { 45 }
    ::= { boxServicesGroup 2 }

    boxServicesTemperatureTrapEnable OBJECT-TYPE
      SYNTAX      INTEGER {
                  enable(1),
                  disable(2)
                  }
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
       " Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range"
      DEFVAL { enable }
    ::= { boxServicesGroup 3 }

    boxServicesPSMStateTrapEnable OBJECT-TYPE
      SYNTAX      INTEGER {
                  enable(1),
                  disable(2)
                  }
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
       " Enable or disable Power Supply Module state change trap."
      DEFVAL { enable }
    ::= { boxServicesGroup 4 }
    
    boxServicesFanStateTrapEnable OBJECT-TYPE
      SYNTAX      INTEGER {
                  enable(1),
                  disable(2)
                  }
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
       " Enable or disable Fan state change trap."
      DEFVAL { enable }
    ::= { boxServicesGroup 5 }



    boxServicesThermalShutdownSensor         OBJECT-TYPE 
         SYNTAX      Unsigned32
         MAX-ACCESS  accessible-for-notify
         STATUS      current
         DESCRIPTION
            "The number of the sensor which initiated thermal shutdown."

         ::= { boxServicesGroup 13 }

    boxServicesThermalShutdownTemperature    OBJECT-TYPE 
         SYNTAX      Unsigned32
         MAX-ACCESS  accessible-for-notify
         STATUS      current
         DESCRIPTION
            "The temperature of the sensor which initiated thermal shutdown."

         ::= { boxServicesGroup 14 }

   --**************************************************************************************
   -- boxServicesFans

    boxServicesFansTable OBJECT-TYPE
         SYNTAX SEQUENCE OF BoxServicesFansEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Fan"
         ::= { boxServicesGroup 6 }

    boxServicesFansEntry OBJECT-TYPE
         SYNTAX      BoxServicesFansEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Box Services Fan Entry"
         INDEX { boxServicesFanUnitIndex , boxServicesFansIndex }
         ::= { boxServicesFansTable 1 }

    BoxServicesFansEntry ::= SEQUENCE {
          boxServicesFanUnitIndex
              Unsigned32,
	  boxServicesFansIndex
              Integer32,
          boxServicesFanItemType
              INTEGER,
          boxServicesFanItemState
              INTEGER,
          boxServicesFanSpeed
              OCTET STRING,
          boxServicesFanDutyLevel
              OCTET STRING
          }

    boxServicesFanUnitIndex OBJECT-TYPE
         SYNTAX      Unsigned32
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "Unit index for an entry in the Box Services Fan Table"
         ::= { boxServicesFansEntry 6 }

    boxServicesFansIndex OBJECT-TYPE
         SYNTAX      Integer32 (0..2147483647)
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "Unique index of fan table entry"
         ::= { boxServicesFansEntry 1 }

    boxServicesFanItemType OBJECT-TYPE
             SYNTAX      INTEGER {
                                  fixed(1),
                                  removable(2),
                                  fixedAC(3),
                                  removableDC(4),
                                  fixedDC(5),
                                  removableAC(6)
                                 }
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "The type of fan"
         ::= { boxServicesFansEntry 2 }


    boxServicesFanItemState OBJECT-TYPE
             SYNTAX      INTEGER {
                                  notpresent(1),
                                  operational(2),
                                  failed(3),
                                  powering(4),
                                  nopower(5),
                                  notpowering(6),
                                  incompatible(7)
                                 }
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "The status of fan. nopower(4) - This state means the fan is present but no AC is connected."
         ::= { boxServicesFansEntry 3 }


      boxServicesFanSpeed OBJECT-TYPE
             SYNTAX      OCTET STRING (SIZE (13))
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                          "The speed of fan"
         ::= { boxServicesFansEntry 4}
         
      boxServicesFanDutyLevel OBJECT-TYPE
             SYNTAX      OCTET STRING (SIZE (13))
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                          "The duty level of fan, in percents"
         ::= { boxServicesFansEntry 5}


   --**************************************************************************************
   -- boxServicesPowSupplies

    boxServicesPowSuppliesTable OBJECT-TYPE
         SYNTAX SEQUENCE OF BoxServicesPowSuppliesEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Power supply"
         ::= { boxServicesGroup 7 }

    boxServicesPowSuppliesEntry OBJECT-TYPE
         SYNTAX      BoxServicesPowSuppliesEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Box Services Power Supply Entry"
         INDEX { boxServicesPowerSuppUnitIndex, boxServicesPowSupplyIndex }
         ::= { boxServicesPowSuppliesTable 1 }

    BoxServicesPowSuppliesEntry ::= SEQUENCE {
          boxServicesPowerSuppUnitIndex
              Unsigned32,
	  boxServicesPowSupplyIndex
              Integer32,
          boxServicesPowSupplyItemType
              INTEGER,
          boxServicesPowSupplyItemState
              INTEGER
          }

    boxServicesPowerSuppUnitIndex OBJECT-TYPE
         SYNTAX      Unsigned32
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "Unit index for an entry in the Box Services Power Supply Table"
         ::= { boxServicesPowSuppliesEntry 4 }

    boxServicesPowSupplyIndex OBJECT-TYPE
         SYNTAX      Integer32 (0..2147483647)
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "Unique index of power supply table entry"
         ::= { boxServicesPowSuppliesEntry 1 }

    boxServicesPowSupplyItemType OBJECT-TYPE
             SYNTAX      INTEGER {
                                  fixed(1),
                                  removable(2),
                                  fixedAC(3),
                                  removableDC(4),
                                  fixedDC(5),
                                  removableAC(6) 
                                 }
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "The type of power supply"
         ::= { boxServicesPowSuppliesEntry 2 }


    boxServicesPowSupplyItemState OBJECT-TYPE
             SYNTAX      INTEGER {
                                  notpresent(1),
                                  operational(2),
                                  failed(3),
                                  powering(4),
                                  nopower(5),
                                  notpowering(6),
                                  incompatible(7)
                                 }
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "The status of power supply. nopower(5) - This state means the power supply is present but no AC is connected.
                                                  incompatible(7) - This state is possible on boards capable of pluggable Power supplies"
         ::= { boxServicesPowSuppliesEntry 3 }


         
   --**************************************************************************************
   -- boxServicesTempSensors


    boxServicesTempSensorsTable OBJECT-TYPE
         SYNTAX SEQUENCE OF BoxServicesTempSensorsEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Temperature sensor"
         ::= { boxServicesGroup 8 }


    boxServicesTempSensorsEntry OBJECT-TYPE
         SYNTAX      BoxServicesTempSensorsEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Box Services Temperature Sensor Entry"
         INDEX { boxServicesUnitIndex, boxServicesTempSensorIndex }
         ::= { boxServicesTempSensorsTable 1 }

    BoxServicesTempSensorsEntry ::= SEQUENCE {
          boxServicesUnitIndex
              Unsigned32,
          boxServicesTempSensorIndex
              Unsigned32,
          boxServicesTempSensorType
              INTEGER,
          boxServicesTempSensorState
              BoxsTemperatureStatus,
          boxServicesTempSensorTemperature
              Integer32
          }
    
    boxServicesUnitIndex OBJECT-TYPE
         SYNTAX      Unsigned32
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
		     "Unit index for an entry in the Box Services Temperature Sensor Table"
         ::= { boxServicesTempSensorsEntry 1 }

    boxServicesTempSensorIndex OBJECT-TYPE
         SYNTAX      Unsigned32
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "Unique index of temperature sensor table entry"
         ::= { boxServicesTempSensorsEntry 2 }


    boxServicesTempSensorType OBJECT-TYPE
             SYNTAX      INTEGER {
                                  fixed(1),
                                  removable(2),
                                  fixedAC(3),
                                  removableDC(4),
                                  fixedDC(5),
                                  removableAC(6)
                                 }
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "The type of temperature sensor"
         ::= { boxServicesTempSensorsEntry 3 }


    boxServicesTempSensorState OBJECT-TYPE
         SYNTAX      BoxsTemperatureStatus 
         MAX-ACCESS  read-only
         STATUS      obsolete
         DESCRIPTION
                     "The state of temperature sensor"
         ::= { boxServicesTempSensorsEntry 4 }


      boxServicesTempSensorTemperature OBJECT-TYPE
             SYNTAX      Integer32
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                          "The temperature value reported by sensor"
         ::= { boxServicesTempSensorsEntry 5 }

    boxServicesTempUnitTable OBJECT-TYPE
        SYNTAX SEQUENCE OF BoxServicesTempUnitEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Temperature status table"
        ::= { boxServicesGroup 15 }

    boxServicesTempUnitEntry OBJECT-TYPE
        SYNTAX      BoxServicesTempUnitEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Box Services Temperature Unit Entry"
        INDEX { boxServicesTempUnitIndex }
        ::= { boxServicesTempUnitTable 1 }

    BoxServicesTempUnitEntry ::= SEQUENCE {
        boxServicesTempUnitIndex
           Unsigned32,
        boxServicesTempUnitState
           BoxsTemperatureStatus,
        boxServicesTempUnitTemperature
           Integer32
        }

    boxServicesTempUnitIndex OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only 
        STATUS      current
        DESCRIPTION
            "Unit index for an entry in the Box Services Temperature Unit Table"
        ::= { boxServicesTempUnitEntry 1 }

    boxServicesTempUnitState OBJECT-TYPE
        SYNTAX      BoxsTemperatureStatus 
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The temperature state of the unit"
        ::= { boxServicesTempUnitEntry 2 }

    boxServicesTempUnitTemperature OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The highest temperature currently reported by any sensor on the unit"
        ::= { boxServicesTempUnitEntry 3 }

--**************************************************************************************
--    boxServicesNotificationsGroup
--
--    This group provides notification definitions for the Box Services
--    feature.  
--
--**************************************************************************************

	boxServicesNotificationsGroup               OBJECT IDENTIFIER ::= { fastPathBoxServices 2 }

   --**************************************************************************************
   -- boxServices notification definitions

      boxsItemStateChangeEvent OBJECT-TYPE
        SYNTAX INTEGER  {
             insertion(1),
             removal(2),
             becomeoperational(3),
             failure(4),
	     losepower(5)
        }
        MAX-ACCESS  accessible-for-notify
        STATUS  current
        DESCRIPTION
           "This event describes states of the fan or power supply.
           
             insertion          - hot-pluggable fan or power supply was inserted
             removal            - hot-pluggable fan or power supply was removed
             becomeoperational  - fan or power supply became operational after failure state
             failure            - fan or power supply failure happened, i.e. it is not able to perform its functions
             losepower          - a power supply was operational, but the power to it has been disconnected or has failed"
        ::= { boxServicesNotificationsGroup 1 }

      boxsTemperatureChangeEvent OBJECT-TYPE
        SYNTAX INTEGER  {
             abovethreshold(1),
             belowthreshold(2),
             withinnormalrange(3)
        }
        MAX-ACCESS  accessible-for-notify
        STATUS  current
        DESCRIPTION
           "This event describes change of the temperature. 
           To avoid flipping on boundary conditions, it is allowed to send the trap 
           taking into account some margin around thresholds.
           
             abovethreshold     - temperature increased and crossed upper threshold value
             belowthreshold     - temperature decreased and crossed lower threshold value
             withinnormalrange  - temperature returned to normal range (between threshold)"
        ::= { boxServicesNotificationsGroup 2 }

    boxsTemperatureStatusCurrentEvent OBJECT-TYPE
        SYNTAX      BoxsTemperatureStatus
        MAX-ACCESS  accessible-for-notify
        STATUS      current
        DESCRIPTION
            "This event describes the current status of a switch."
        ::= { boxServicesNotificationsGroup 3 }

    boxsTemperatureStatusPreviousEvent OBJECT-TYPE
        SYNTAX      BoxsTemperatureStatus
        MAX-ACCESS  accessible-for-notify
        STATUS      current
        DESCRIPTION
            "This event describes the previous status of a switch."
        ::= { boxServicesNotificationsGroup 4 }



--**************************************************************************************
--   Traps
--**************************************************************************************

     fastPathBoxServicesTraps OBJECT IDENTIFIER ::= { fastPathBoxServices 0 }



     boxsFanStateChange NOTIFICATION-TYPE
         OBJECTS {
                      boxServicesFansIndex,
                      boxsItemStateChangeEvent
                 }
         STATUS             current
         DESCRIPTION
             "Trap is sent when fan state change happens."
         ::= { fastPathBoxServicesTraps 1 }

     boxsPowSupplyStateChange NOTIFICATION-TYPE
         OBJECTS {
                      boxServicesPowSupplyIndex,
                      boxsItemStateChangeEvent
                 }
         STATUS             current
         DESCRIPTION
             "Trap is sent when power supply state change happens."
         ::= { fastPathBoxServicesTraps 2 }


     boxsTemperatureChange NOTIFICATION-TYPE
         OBJECTS {
                      boxServicesTempSensorIndex,
                      boxsTemperatureChangeEvent
                 }
         STATUS             obsolete
         DESCRIPTION
             "Trap is sent when temperature is changing and crossing any of the thresholds"
         ::= { fastPathBoxServicesTraps 3 }


     boxsThermalShutdown NOTIFICATION-TYPE
         OBJECTS {
                   boxServicesThermalShutdownSensor,
                   boxServicesThermalShutdownTemperature
                 }
         STATUS             current
         DESCRIPTION
             "Trap is sent when thermal shutdown is initiated."
         ::= { fastPathBoxServicesTraps 4 }


    boxsTemperatureStateChange NOTIFICATION-TYPE
        OBJECTS {
                     boxServicesTempUnitIndex,
                     boxsTemperatureStatusCurrentEvent,
                     boxsTemperatureStatusPreviousEvent
                }
        STATUS             current
        DESCRIPTION
            "Trap is sent when the system temperature crosses a threshold. 
            To avoid rapid flapping between states, a hysteresis may
            be applied."
        ::= { fastPathBoxServicesTraps 5 }

--**************************************************************************************
--    Locator LED manage group
--
--    This group provides manage definitions for the Locator LED feature.  
--
--**************************************************************************************

    boxsLocatorLedConfigGroup                 OBJECT IDENTIFIER ::= { fastPathBoxServices 4 }

    boxsLocatorLedUnit OBJECT-TYPE
         SYNTAX      INTEGER
         MAX-ACCESS  read-write
         STATUS      current
         DESCRIPTION
                     "Spesifies unit number where Locator LED should blink on.
                      This is write-only value. It always returns '0' on request
                      if the Locator Led feature is supported."
          ::= { boxsLocatorLedConfigGroup 1 }

    boxsLocatorLedTime OBJECT-TYPE
         SYNTAX      INTEGER
         MAX-ACCESS  read-write
         STATUS      current
         DESCRIPTION
                     "Indicates time period in seconds for Locator LED blinking.
                      The range is from 20 to 3600 seconds.
                      The dafault value is 20 seconds.
                      This is write-only value. It always returns '0' on request
                      if the Locator Led feature is supported."
         DEFVAL { 20 }
          ::= { boxsLocatorLedConfigGroup 2 }

    boxsLocatorLedEnable OBJECT-TYPE
         SYNTAX      INTEGER {
                       disable(0), 
                       enable(1)
                     }
         MAX-ACCESS  read-write
         STATUS      current
         DESCRIPTION
                     "Starts the Locator LED blinking.
                      If boxsLocatorLedUnit has not been set current(manager) unit number will be used.
                      If boxsLocatorLedTime has not been set default value(20 seconds) will be used.
                      This is write-only value. It always returns '0' on request
                      if the Locator Led feature is supported."
         ::= { boxsLocatorLedConfigGroup 3 }

END