summaryrefslogtreecommitdiff
path: root/MIBS/mitsubishi/UPS-MIB
blob: f1c84ee6bfe215a0b7df3ac3c0e197e926cfa221 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
-- Mitsubishi.mib  - MIB file for Mitsubishi UPSs

UPS-MIB DEFINITIONS ::= BEGIN

IMPORTS
        TRAP-TYPE
                FROM RFC-1215
        DisplayString
                FROM RFC1213-MIB
        OBJECT-TYPE
                FROM RFC-1212
        Gauge, Counter, TimeTicks, mgmt
                FROM RFC1155-SMI
            ;

PositiveInteger		::= INTEGER
NonNegativeInteger 	::= INTEGER
TimeStamp 			::= TimeTicks
TimeInterval 		::= INTEGER (0..2147483647)
TestAndIncr 		::= INTEGER (0..2147483647)
AutonomousType 		::= DisplayString

Tag			OBJECT IDENTIFIER ::= { enterprises 13891 }
MitsubishiUPS 	OBJECT IDENTIFIER ::= { Tag 101 }

upsIdent OBJECT IDENTIFIER ::= { MitsubishiUPS 1 }

upsIdentManufacturer OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The name of the UPS manufacturer."
    ::= { upsIdent 1 }

upsIdentModel OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The UPS Model designation."
    ::= { upsIdent 2 }

upsIdentUPSSoftwareVersion OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The UPS firmware/software version(s).  This variable
            may or may not have the same value as
            upsIdentAgentSoftwareVersion in some implementations."
    ::= { upsIdent 3 }

upsIdentAgentSoftwareVersion OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The UPS agent software version.  This variable may or may
             not have the same value as upsIdentUPSSoftwareVersion in 
             some implementations."
    ::= { upsIdent 4 }

upsIdentName OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "A string identifying the UPS.  This object should be
            set by the administrator."
    ::= { upsIdent 5 }

upsIdentAttachedDevices OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "A string identifying the devices attached to the output
            of the UPS.  This object should be set by the administrator."
    ::= { upsIdent 6 }

upsBattery OBJECT IDENTIFIER ::= { MitsubishiUPS 2 }

upsBatteryStatus OBJECT-TYPE
    SYNTAX  INTEGER 
    {
        unknown(1),
        batteryNormal(2),
        batteryLow(3),
        batteryDepleted(4)
    }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The indication of the capacity remaining in the UPS batteries.   
            A value of batteryNormal indicates a normal battery condition.  
            A value of batteryLow indicates the remaining battery run-time 
            will not maintain the output load for an extended period of time.
            A value of batteryDepleted indicates that the UPS will be unable
            to sustain the present load when and if the utility power is lost." 
    ::= { upsBattery 1 }

upsSecondsOnBattery OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS seconds
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "If the unit is on battery power, the elapsed time in seconds
            since the UPS last switched to battery power, or the time since 
            the network management system was last restarted, whichever is less.  
            Zero shall be returned if the unit is not on battery power."
    ::= { upsBattery 2 }

upsEstimatedMinutesRemaining OBJECT-TYPE
    SYNTAX  PositiveInteger     -- UNITS minutes
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "An estimate of the time in minutes until the battery is depleted
            under the present load conditions if the utility power is off and 
            remains off, or if it were to be lost and remain off."
    ::= { upsBattery 3 }

upsEstimatedChargeRemaining OBJECT-TYPE
    SYNTAX  INTEGER     -- UNITS percent
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "An estimate of the battery charge remaining expressed as a 
            percent of full charge."
    ::= { upsBattery 4 }

upsBatteryVoltage OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS 0.1 Volt DC
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The magnitude of the present battery voltage (0.1 Volt DC)."
    ::= { upsBattery 5 }

upsBatteryCurrent OBJECT-TYPE
    SYNTAX  INTEGER (-2147483648..2147483647)   -- UNITS 0.1 Amp DC
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The present battery current (0.1 Amp DC)."
    ::= { upsBattery 6 }

upsBatteryTemperature OBJECT-TYPE
    SYNTAX  INTEGER (-2147483648..2147483647)   -- UNITS degrees Centigrade
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The ambient temperature at or near the UPS Battery casing (degrees Centigrade)."
    ::= { upsBattery 7 }

upsInput OBJECT IDENTIFIER ::= { MitsubishiUPS 3 }

upsInputLineBads OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "A count of the number of times the input entered an
            out-of-tolerance condition as defined by the manufacturer.  
            This count is incremented by one each time the input 
            transitions from zero out-of-tolerance lines to one or more 
            input lines out-of-tolerance."
    ::= { upsInput 1 }

upsInputNumLines OBJECT-TYPE
    SYNTAX  NonNegativeInteger
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The number of input lines utilized in this device.  This
            variable indicates the number of rows in the input table."
    ::= { upsInput 2 }

upsInputTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF UpsInputEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
           "A list of input table entries.  The number of entries
            is given by the value of upsInputNumLines."
    ::= { upsInput 3 }

upsInputEntry OBJECT-TYPE
    SYNTAX  UpsInputEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
           "An entry containing information applicable to a
            particular input line."
    INDEX   { upsInputLineIndex }
    ::= { upsInputTable  1 }

UpsInputEntry ::=
    SEQUENCE 
    {
        upsInputLineIndex PositiveInteger,
        upsInputFrequency NonNegativeInteger,
        upsInputVoltage   NonNegativeInteger,
        upsInputCurrent   NonNegativeInteger,
        upsInputTruePower NonNegativeInteger
    }

upsInputLineIndex OBJECT-TYPE
    SYNTAX  PositiveInteger
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The input line identifier."
    ::= { upsInputEntry 1 }

upsInputFrequency OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS 0.1 Hertz
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The present input frequency (0.1 Hertz)."
    ::= { upsInputEntry 2 }

upsInputVoltage OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS 0.1 RMS Volt
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The magnitude of the present input voltage (0.1 RMS Volt)."
    ::= { upsInputEntry 3 }

upsInputCurrent OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS 0.1 RMS Amp
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The magnitude of the present input current (0.1 RMS Amp)."
    ::= { upsInputEntry 4 }

upsInputTruePower OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS Watts
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The magnitude of the present input true power (watts)."
    ::= { upsInputEntry 5 }

upsOutput OBJECT IDENTIFIER ::= { MitsubishiUPS 4 }

upsOutputSource OBJECT-TYPE
    SYNTAX  INTEGER 
    {
        other(1),
        none(2),
        normal(3),
        bypass(4),
        battery(5),
        booster(6),
        reducer(7)
    }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The present source of output power.  A value of none (2) indicates
            there is no source of output power (and therefore no output power), 
            for example, the system has opened the output breaker."
    ::= { upsOutput 1 }

upsOutputFrequency OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS 0.1 Hertz
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The present output frequency (0.1 Hertz)."
    ::= { upsOutput 2 }

upsOutputNumLines OBJECT-TYPE
    SYNTAX  NonNegativeInteger
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The number of output lines utilized in this device.  This
            variable indicates the number of rows in the output table."
    ::= { upsOutput 3 }

upsOutputTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF UpsOutputEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
           "A list of output table entries.  The number of
            entries is given by the value of upsOutputNumLines."
    ::= { upsOutput 4 }

upsOutputEntry OBJECT-TYPE
    SYNTAX  UpsOutputEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
           "An entry containing information applicable to a
            particular output line."
    INDEX   { upsOutputLineIndex }
    ::= { upsOutputTable 1 }

UpsOutputEntry ::=
    SEQUENCE 
    {
        upsOutputLineIndex          PositiveInteger,
        upsOutputVoltage            NonNegativeInteger,
        upsOutputCurrent            NonNegativeInteger,
        upsOutputPower              NonNegativeInteger,
        upsOutputPercentLoad        INTEGER
    }

upsOutputLineIndex OBJECT-TYPE
    SYNTAX  PositiveInteger
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The output line identifier."
    ::= { upsOutputEntry 1 }

upsOutputVoltage OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS 0.1 RMS Volts
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The present output voltage (0.1 RMS Volt)."
    ::= { upsOutputEntry 2 }

upsOutputCurrent OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS 0.1 RMS Amp
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The present output current (0.1 RMS Amp)."
    ::= { upsOutputEntry 3 }

upsOutputPower OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS Watts
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The present output true power (watts)."
    ::= { upsOutputEntry 4 }

upsOutputPercentLoad OBJECT-TYPE
    SYNTAX  INTEGER     -- UNITS percent
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The percentage of the UPS power capacity presently being 
            used on this output line (the greater of the percent load 
            of true power capacity and the percent load of VA."
    ::= { upsOutputEntry 5 }

upsBypass OBJECT IDENTIFIER ::= { MitsubishiUPS 5 }

upsBypassFrequency OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS 0.1 Hertz
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The present bypass frequency."
    ::= { upsBypass 1 }

upsBypassNumLines OBJECT-TYPE
    SYNTAX  NonNegativeInteger
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The number of bypass lines utilized in this device.  This
            entry indicates the number of rows in the bypass table."
    ::= { upsBypass 2 }

upsBypassTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF UpsBypassEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
           "A list of bypass table entries.  The number of entries
            is given by the value of upsBypassNumLines."
    ::= { upsBypass 3 }

upsBypassEntry OBJECT-TYPE
    SYNTAX  UpsBypassEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
           "An entry containing information applicable to a
            particular bypass input."
    INDEX   { upsBypassLineIndex }
    ::= { upsBypassTable 1 }

UpsBypassEntry ::=
    SEQUENCE 
    {
        upsBypassLineIndex          PositiveInteger,
        upsBypassVoltage            NonNegativeInteger,
        upsBypassCurrent            NonNegativeInteger,
        upsBypassPower              NonNegativeInteger
    }

upsBypassLineIndex OBJECT-TYPE
    SYNTAX  PositiveInteger
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The bypass line identifier."
    ::= { upsBypassEntry 1 }

upsBypassVoltage OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS 0.1 RMS Volts
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The present bypass voltage (0.1 RMS Volt)."
    ::= { upsBypassEntry 2 }

upsBypassCurrent OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS 0.1 RMS Amp
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The present bypass current (0.1 RMS Amp)."
    ::= { upsBypassEntry 3 }

upsBypassPower OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS Watts
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The present true power conveyed by the bypass (watts)."
    ::= { upsBypassEntry 4 }

upsAlarm OBJECT IDENTIFIER ::= { MitsubishiUPS 6 }

upsAlarmsPresent OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The present number of active alarm conditions."
    ::= { upsAlarm 1 }

upsAlarmTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF UpsAlarmEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
           "A list of alarm table entries.  Alarms are named by 
            an OBJECT IDENTIFIER, upsAlarmDescr, to allow a single 
            table to reflect well known alarms plus alarms defined 
            by a particular implementation, i.e., as documented in
            the private enterprise MIB definition for the device.  
            No two rows will have the same value of upsAlarmDescr,
            since alarms define conditions.  In order to meet this
            requirement, care should be taken in the definition of
            alarm conditions to insure that a system cannot enter
            the same condition multiple times simultaneously.

            The number of rows in the table at any given time is
            reflected by the value of upsAlarmsPresent."
    ::= { upsAlarm 2 }

upsAlarmEntry OBJECT-TYPE
    SYNTAX  UpsAlarmEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
           "An entry containing information applicable to a
            particular alarm."
    INDEX   { upsAlarmId }
    ::= { upsAlarmTable 1 }

UpsAlarmEntry ::=
    SEQUENCE 
    {
        upsAlarmId            PositiveInteger,
        upsAlarmDescr         AutonomousType,
        upsAlarmTime          TimeStamp
    }

upsAlarmId OBJECT-TYPE
    SYNTAX  PositiveInteger
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "A unique identifier for an alarm condition.  This
            value must remain constant."
    ::= { upsAlarmEntry  1 }

upsAlarmDescr OBJECT-TYPE
    SYNTAX  AutonomousType
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "A reference to an alarm description object.  The object
            referenced should not be accessible, but rather be used
            to provide a unique description of the alarm condition."
    ::= { upsAlarmEntry 2 }

upsAlarmTime OBJECT-TYPE
    SYNTAX  TimeStamp
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The value of sysUpTime when the alarm condition was
            detected.  If the alarm condition was detected at the
            time of agent startup and presumably existed before
            agent startup, the value of upsAlarmTime shall equal 0."
    ::= { upsAlarmEntry 3 }

  upsAlarmID OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
              "A unique identifier for an alarm condition.  This
               value must remain constant."
      ::= { upsAlarm 4 }

  upsAlarmDESCR OBJECT-TYPE
      SYNTAX DisplayString (SIZE(0..63))
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
              "A reference to an alarm description object.  The object
               references should not be accessible, but rather be used
               to provide a unique description of the alarm condition."
      ::= { upsAlarm 5 }

upsWellKnownAlarms OBJECT IDENTIFIER ::= { upsAlarm 3 }

upsAlarmBatteryBad OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
              "One or more batteries have been determined to require
               replacement."
      ::= { upsWellKnownAlarms 1 }

upsAlarmOnBattery OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
              "The UPS is drawing power from the batteries."
      ::= { upsWellKnownAlarms 2 }

  upsAlarmLowBattery OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
               "The remaining battery run-time is less than or equal
                to upsConfigLowBattTime."
      ::= { upsWellKnownAlarms 3 }

  upsAlarmDepletedBattery OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
              "The UPS will be unable to sustain the present load
               when and if the utility power is lost."
      ::= { upsWellKnownAlarms 4 }

  upsAlarmTempBad OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
              "A temperature is out of tolerance."
      ::= { upsWellKnownAlarms 5 }

   upsAlarmInputBad OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
       DESCRIPTION
               "An input condition is out of tolerance."
       ::= { upsWellKnownAlarms  6 }

   upsAlarmOutputBad OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
       DESCRIPTION
               "An output condition (other than OutputOverload) is
               out of tolerance."
       ::= { upsWellKnownAlarms  7 }

  upsAlarmOutputOverload OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
              "The output load exceeds the UPS output capacity."
      ::= { upsWellKnownAlarms 8 }

    upsAlarmOnBypass OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
       DESCRIPTION
               "The Bypass is presently engaged on the UPS."
       ::= { upsWellKnownAlarms  9 }

   upsAlarmBypassBad OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
       DESCRIPTION
               "The Bypass is out of tolerance."
       ::= { upsWellKnownAlarms 10 }

 upsAlarmOutputOffAsRequested OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
               "The UPS has shut down as requested, i.e., the output
                is off."
      ::= { upsWellKnownAlarms 11 }

upsAlarmUpsOffAsRequested OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
       DESCRIPTION
               "The entire UPS has shutdown as commanded."
       ::= { upsWellKnownAlarms 12 }

upsAlarmChargerFailed OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
       DESCRIPTION
               "An uncorrected problem has been detected within the
                UPS charger subsystem."
       ::= { upsWellKnownAlarms 13 }

upsAlarmUpsOutputOff OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
               "The output of the UPS is in the off state."
      ::= { upsWellKnownAlarms 14 }

upsAlarmUpsSystemOff OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
       DESCRIPTION
               "The UPS system is in the off state."
       ::= { upsWellKnownAlarms 15 }

upsAlarmFanFailure OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
               "The failure of one or more fans in the UPS has been
               detected."
       ::= { upsWellKnownAlarms 16 }

upsAlarmFuseFailure OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
               "The failure of one or more fuses has been detected."
      ::= { upsWellKnownAlarms 17 }

upsAlarmGeneralFault OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
               "A general fault in the UPS has been detected."
      ::= { upsWellKnownAlarms 18 }

 upsAlarmDiagnosticTestFailed OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
              "The result of the last diagnostic test indicates a
               failure."
      ::= { upsWellKnownAlarms 19 }

  upsAlarmCommunicationsLost OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
              "A problem has been encountered in the
               communications between the agent and the UPS."
      ::= { upsWellKnownAlarms 20 }

upsAlarmAwaitingPower OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
               "The UPS output is off and the UPS is awaiting the
                return of input power."
      ::= { upsWellKnownAlarms 21 }

 upsAlarmShutdownPending OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
              "A upsShutdownAfterDelay countdown is underway."
      ::= { upsWellKnownAlarms 22 }

  upsAlarmShutdownImminent OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
       DESCRIPTION
               "The UPS will turn off power to the load in less than
                5 seconds; this may be either a timed shutdown or a
                low battery shutdown."
      ::= { upsWellKnownAlarms 23 }

  upsAlarmTestInProgress OBJECT-TYPE
      SYNTAX INTEGER
      ACCESS read-only
      STATUS mandatory
       DESCRIPTION
               "A test is in progress, as initiated and indicated by
                the Test Group.  Tests initiated via other
                implementation-specific mechanisms can indicate the
                presence of the testing in the alarm table, if
                desired, via a OBJECT-TYPE macro in the MIB
                document specific to that implementation and are
                outside the scope of this OBJECT-TYPE."
       ::= { upsWellKnownAlarms 24 }

upsTest OBJECT IDENTIFIER ::= { MitsubishiUPS 7 }

  upsTestId OBJECT-TYPE
      SYNTAX OBJECT IDENTIFIER 
      ACCESS read-write
      STATUS mandatory
      DESCRIPTION
              "The test named by an OBJECT IDENTIFIER which
               allows a standard mechanism for the initiation of
               a test, including the well known tests identified in
               this document."
      ::= { upsTest 1 }

upsTestSpinLock OBJECT-TYPE
    SYNTAX  TestAndIncr
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "A spin lock on the test subsystem."
    ::= { upsTest 2 }

upsTestResultsSummary OBJECT-TYPE
    SYNTAX  INTEGER 
    {
        donePass(1),
        doneWarning(2),
        doneError(3),
        aborted(4),
        inProgress(5),
        noTestsInitiated(6)
    }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The results of the current or last UPS diagnostics
            test performed.  The values for donePass(1),
            doneWarning(2), and doneError(3) indicate that the
            test completed either successfully, with a warning, or
            with an error, respectively.  The value aborted(4) is
            returned for tests which are aborted by setting the
            value of upsTestId to upsTestAbortTestInProgress.
            Tests which have not yet concluded are indicated by
            inProgress(5).  The value noTestsInitiated(6)
            indicates that no previous test results are available,
            such as is the case when no tests have been run since
            the last reinitialization of the network management
            subsystem and the system has no provision for non-
            volatile storage of test results."
    ::= { upsTest 3 }

upsTestResultsDetail OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "Additional information about upsTestResultsSummary.
            If no additional information available, a zero length
            string is returned."
    ::= { upsTest 4 }

upsTestStartTime OBJECT-TYPE
    SYNTAX  TimeStamp
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The value of sysUpTime at the time the test in
            progress was initiated, or, if no test is in progress,
            the time the previous test was initiated.  If the
            value of upsTestResultsSummary is noTestsInitiated(6),
            upsTestStartTime has the value 0."
    ::= { upsTest 5 }

upsTestElapsedTime OBJECT-TYPE
    SYNTAX  TimeInterval
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The amount of time, in TimeTicks, since the test in
            progress was initiated, or, if no test is in progress,
            the previous test took to complete.  If the value of
            upsTestResultsSummary is noTestsInitiated(6),
            upsTestElapsedTime has the value 0."
    ::= { upsTest 6 }

upsWellKnownTests OBJECT IDENTIFIER ::= { upsTest  7 }

upsTestNoTestsInitiated OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
           "No tests have been initiated and no test is in progress."
    ::= { upsWellKnownTests 1 }

upsTestAbortTestInProgress OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
           "The test in progress is to be aborted / the test in
            progress was aborted."
    ::= { upsWellKnownTests 2 }

upsTestGeneralSystemsTest OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
           "The manufacturer's standard test of UPS device systems."
    ::= { upsWellKnownTests  3 }

upsTestQuickBatteryTest OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
           "A test that is sufficient to determine if the battery
            needs replacement."
    ::= { upsWellKnownTests 4 }

upsTestDeepBatteryCalibration OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
           "The system is placed on battery to a discharge level,
            set by the manufacturer, sufficient to determine
            battery replacement and battery run-time with a high
            degree of confidence.  WARNING:  this test will leave
            the battery in a low charge state and will require
            time for recharging to a level sufficient to provide
            normal battery duration for the protected load."
    ::= { upsWellKnownTests 5 }

upsControl OBJECT IDENTIFIER ::= { MitsubishiUPS 8 }

upsShutdownType OBJECT-TYPE
    SYNTAX  INTEGER 
    {
        output(1),
        system(2)
    }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "This object determines the nature of the action to be
            taken at the time when the countdown of the
            upsShutdownAfterDelay and upsRebootWithDuration
            objects reaches zero.

            Setting this object to output(1) indicates that
            shutdown requests should cause only the output of the
            UPS to turn off.  Setting this object to system(2)
            indicates that shutdown requests will cause the entire
            UPS system to turn off."
    ::= { upsControl 1 }

upsShutdownAfterDelay OBJECT-TYPE
    SYNTAX  INTEGER     -- UNITS seconds
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "Setting this object will shutdown (i.e., turn off)
            either the UPS output or the UPS system (as determined
            by the value of upsShutdownType at the time of
            shutdown) after the indicated number of seconds, or
            less if the UPS batteries become depleted. Setting
            this object to 0 will cause the shutdown to occur
            immediately.  Setting this object to -1 will abort the
            countdown.  If the system is already in the desired
            state at the time the countdown reaches 0, then
            nothing will happen.  That is, there is no additional
            action at that time if upsShutdownType = system and
            the system is already off.  Similarly, there is no
            additional action at that time if upsShutdownType =
            output and the output is already off.  When read,
            upsShutdownAfterDelay will return the number of
            seconds remaining until shutdown, or -1 if no shutdown
            countdown is in effect.  On some systems, if the agent
            is restarted while a shutdown countdown is in effect,
            the countdown may be aborted.  Sets to this object
            override any upsShutdownAfterDelay already in effect."
    ::= { upsControl 2 }

upsStartupAfterDelay OBJECT-TYPE
    SYNTAX  INTEGER     -- UNITS seconds
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "Setting this object will start the output after the
            indicated number of seconds, including starting the
            UPS, if necessary.  Setting this object to 0 will
            cause the startup to occur immediately.  Setting this
            object to -1 will abort the countdown.  If the output
            is already on at the time the countdown reaches 0,
            then nothing will happen.  Sets to this object
            override the effect of any upsStartupAfterDelay
            countdown or upsRebootWithDuration countdown in
            progress.  When read, upsStartupAfterDelay will return
            the number of seconds until startup, or -1 if no
            startup countdown is in effect.  If the countdown
            expires during a utility failure, the startup shall
            not occur until the utility power is restored.  On
            some systems, if the agent is restarted while a
            startup countdown is in effect, the countdown is
            aborted."
    ::= { upsControl 3 }

upsRebootWithDuration OBJECT-TYPE
    SYNTAX  INTEGER     -- UNITS seconds
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "Setting this object will immediately shutdown (i.e.,
            turn off) either the UPS output or the UPS system (as
            determined by the value of upsShutdownType at the time
            of shutdown) for a period equal to the indicated
            number of seconds, after which time the output will be
            started, including starting the UPS, if necessary.  If
            the number of seconds required to perform the request
            is greater than the requested duration, then the
            requested shutdown and startup cycle shall be
            performed in the minimum time possible, but in no case
            shall this require more than the requested duration
            plus 60 seconds.  When read, upsRebootWithDuration
            shall return the number of seconds remaining in the
            countdown, or -1 if no countdown is in progress.  If
            the startup should occur during a utility failure, the
            startup shall not occur until the utility power is
            restored."
    ::= { upsControl 4 }

upsAutoRestart OBJECT-TYPE
    SYNTAX  INTEGER 
    {
        on(1),
        off(2)
    }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "Setting this object to 'on' will cause the UPS system
            to restart after a shutdown if the shutdown occurred
            during a power loss as a result of either a
            upsShutdownAfterDelay or an internal battery depleted
            condition.  Setting this object to 'off' will prevent
            the UPS system from restarting after a shutdown until
            an operator manually or remotely explicitly restarts
            it.  If the UPS is in a startup or reboot countdown,
            then the UPS will not restart until that delay has
            been satisfied."
    ::= { upsControl 5 }

upsConfig OBJECT IDENTIFIER ::= { MitsubishiUPS 9 }

upsConfigInputVoltage OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS RMS Volts
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "The magnitude of the nominal input voltage (RMS Volts).  
            On those systems which support read-write access to this
            object, if there is an attempt to set this variable to
            a value that is not supported, the request must be
            rejected and the agent shall respond with an
            appropriate error message, i.e., badValue for SNMPv1,
            or inconsistentValue for SNMPv2."
    ::= { upsConfig 1 }

upsConfigInputFreq OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS 0.1 Hertz
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "The nominal input frequency (0.1 Hertz).  On those systems
            which support read-write access to this object, if there is
            an attempt to set this variable to a value that is not
            supported, the request must be rejected and the agent
            shall respond with an appropriate error message, i.e.,
            badValue for SNMPv1, or inconsistentValue for SNMPv2."
    ::= { upsConfig 2 }

upsConfigOutputVoltage OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS RMS Volts
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "The magnitude of the nominal output voltage (RMS Volts).  
            On those systems which support read-write access to this
            object, if there is an attempt to set this variable to
            a value that is not supported, the request must be
            rejected and the agent shall respond with an
            appropriate error message, i.e., badValue for SNMPv1,
            or inconsistentValue for SNMPv2."
    ::= { upsConfig 3 }

upsConfigOutputFreq OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS 0.1 Hertz
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "The nominal output frequency (0.1 Hertz).  On those systems 
            which support read-write access to this object, if there is
            an attempt to set this variable to a value that is not
            supported, the request must be rejected and the agent
            shall respond with an appropriate error message, i.e.,
            badValue for SNMPv1, or inconsistentValue for SNMPv2."
    ::= { upsConfig 4 }

upsConfigOutputVA OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS Volt-Amps
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The magnitude of the nominal Volt-Amp rating (Volt-Amps)."
    ::= { upsConfig 5 }

upsConfigOutputPower OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS Watts
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The magnitude of the nominal true power rating (watts)."
    ::= { upsConfig 6 }

upsConfigLowBattTime OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS minutes
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "The value of upsEstimatedMinutesRemaining at which a
            lowBattery condition is declared.  For agents which
            support only discrete (discontinuous) values, then the
            agent shall round up to the next supported value.  If
            the requested value is larger than the largest
            supported value, then the largest supported value
            shall be selected."
    ::= { upsConfig 7 }

upsConfigAudibleStatus OBJECT-TYPE
    SYNTAX  INTEGER 
    {
        disabled(1),
        enabled(2),
        muted(3)
    }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "The requested state of the audible alarm.  When in
            the disabled state, the audible alarm should never
            sound.  The enabled state is self-describing.  Setting
            this object to muted(3) when the audible alarm is
            sounding shall temporarily silence the alarm.  It will
            remain muted until it would normally stop sounding and
            the value returned for read operations during this
            period shall equal muted(3).  At the end of this
            period, the value shall revert to enabled(2).  Writes
            of the value muted(3) when the audible alarm is not
            sounding shall be accepted but otherwise shall have no
            effect."
    ::= { upsConfig 8 }

upsConfigLowVoltageTransferPoint OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS RMS Volts
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "The minimum input line voltage (RMS Volts) allowed before 
            the UPS system transfers to battery backup."
    ::= { upsConfig 9 }

upsConfigHighVoltageTransferPoint OBJECT-TYPE
    SYNTAX  NonNegativeInteger  -- UNITS RMS Volts
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "The maximum line voltage (RMS Volts) allowed before the UPS
            system transfers to battery backup."
    ::= { upsConfig  10 }

-- UPS trap information group
upsTrapInfo OBJECT IDENTIFIER ::= { MitsubishiUPS 10 }

trapCode OBJECT-TYPE
	SYNTAX Unsigned32
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"A number identifying the event for that last trap that was sent."
	::= { upsTrapInfo 1 }

trapDescription OBJECT-TYPE
	SYNTAX DisplayString (SIZE (0..63))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"A string identifying the event for that last trap that was sent."
	::= { upsTrapInfo 2 }

-- UPS Traps
-- upsTraps OBJECT IDENTIFIER ::= { Tag 101 }

alarmCritical TRAP-TYPE
	ENTERPRISE MitsubishiUPS 
	VARIABLES  { trapCode, trapDescription }
	DESCRIPTION
		"Critical alarm."
	::= 1

alarmWarning TRAP-TYPE
	ENTERPRISE MitsubishiUPS
	VARIABLES  { trapCode, trapDescription }
	DESCRIPTION
		"Warning alarm."
	::= 2

alarmInformation TRAP-TYPE
	ENTERPRISE MitsubishiUPS 
	VARIABLES  { trapCode, trapDescription }
	DESCRIPTION
		"Information alarm."
	::= 3

upsAlarmCleared TRAP-TYPE
	ENTERPRISE MitsubishiUPS
	VARIABLES  { trapCode, trapDescription }
	DESCRIPTION
		"Alarm cleared."
	::= 4

upsTrapInitialization TRAP-TYPE
	ENTERPRISE  MitsubishiUPS 
	VARIABLES   { upsIdentName }
	DESCRIPTION
		"This trap is sent each time a NetCom device is initialized."
	::= 5

END