1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
|
LINKSYS-CLI-MIB DEFINITIONS ::= BEGIN
-- Title: LINKSYS ROS
-- Private CLI MIB
-- Version: 7.46
-- Date: 15-Jan-2007
IMPORTS
rnd FROM LINKSYS-MIB
OBJECT-TYPE, MODULE-IDENTITY,
Unsigned32 FROM SNMPv2-SMI
TruthValue, DisplayString, RowStatus FROM SNMPv2-TC;
rlCli MODULE-IDENTITY
LAST-UPDATED "201005250000Z"
ORGANIZATION "
Linksys LLC."
CONTACT-INFO
"www.linksys.com/business/support"
DESCRIPTION
"Remote CLI branch has been added."
REVISION "201005250000Z"
DESCRIPTION
"This private MIB module defines CLI private MIBs."
REVISION "200701020000Z"
DESCRIPTION
"Initial revision."
::= { rnd 52 }
rlCliMibVersion OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MIB's version, the current version is 3."
::= { rlCli 1 }
rlCliPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CLI Password"
::= { rlCli 2 }
rlCliTimer OBJECT-TYPE
SYNTAX INTEGER (5..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CLI Timer"
::= { rlCli 3 }
rlCliFileEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CLI File Enable/Disable"
::= { rlCli 4 }
rlCliFileEnableAfterReset OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CLI File Enable/Disable After Reset"
::= { rlCli 5 }
rlCLIremoteCLIsupport OBJECT IDENTIFIER ::= { rlCli 6 }
--- Remote CLI Scalars
rlCLIremoteCLIcommand OBJECT-TYPE
SYNTAX INTEGER { takeRemoteCLI(1),
releaseRemoteCLI(2),
applySentCLI(3),
deleteCommandsCLI(4),
setEchoModeCLI(5),
unsetEchoModeCLI(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Commands that can be given for execution of CLI from remote:
takeRemoteCLI: take resources of remote CLI activation
releaseRemoteCLI: free resources of remote CLI activation
applySentCLI: apply the CLI commands that are currently in
rlCLIremoteCLIcommandsTable.
deleteCommandsCLI: delete all the CLI commands that are currently in
rlCLIremoteCLIcommandsTable.
setEchoModeCLI: entered commands will appear before its output
in rlCLIremoteCLIoutputsTable.
unsetEchoModeCLI: entered commands will not appear
in rlCLIremoteCLIoutputsTable."
::= { rlCLIremoteCLIsupport 1 }
rlCLIremoteCLIexecutionState OBJECT-TYPE
SYNTAX INTEGER { free(1),
notActive(2),
inProcess(3),
outputAvailable(4),
waitingForOutputRetrieval(5),
done(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The execution state of remote CLI:
notActive: no 'applySentCLI' command has been given.
This is the default state. The remote CLI reverts to
this state each time when the 1st entry is added to
rlCLIremoteCLIcommandsTable.
inProcess: Executing commands - no output available
outputAvailable: Some output is already available, although
the commands execution may not be finished yet.
waitingForOutputRetrieval: The rlCLIremoteCLIoutputsTable is full
and remote CLI is waiting for the manager
to retrieve the output.
done: All the commands in rlCLIremoteCLIcommandsTable
have been executed."
::= { rlCLIremoteCLIsupport 2 }
rlCLIremoteCLIexecutionCommandIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of command, which is currently in execution. 0 if none."
::= { rlCLIremoteCLIsupport 3 }
rlCLIremoteCLImode OBJECT-TYPE
SYNTAX INTEGER { deleteCLIOutputOnGet(1),
keepCLIOutputOnGet(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Operation mode of remote CLI:
deleteCLIOutputOnGet: output row will be deleted after GET.
Recommended for reliable management channels.
keepCLIOutputOnGet: output row will be kept after GET,
will be deleted only explicitly by remote
CLI client or upon release of remote CLI
resources. Recommended for non-reliable
management channels."
DEFVAL {deleteCLIOutputOnGet}
::= { rlCLIremoteCLIsupport 4 }
--- Remote CLI Tables
--- rlCLIremoteCLIcommandsTable
rlCLIremoteCLIcommandsTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlCLIremoteCLIcommandsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of CLI commands to execute."
::= { rlCLIremoteCLIsupport 5 }
rlCLIremoteCLIcommandsEntry OBJECT-TYPE
SYNTAX RlCLIremoteCLIcommandsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing a part of a CLI command."
INDEX { rlCLIremoteCLIcommandIndex, rlCLIremoteCLIcommandPartNumber }
::= { rlCLIremoteCLIcommandsTable 1 }
RlCLIremoteCLIcommandsEntry ::=
SEQUENCE { rlCLIremoteCLIcommandIndex Unsigned32 (1..4294967295),
rlCLIremoteCLIcommandPartNumber Unsigned32 (1..4294967295),
rlCLIremoteCLIcommandPart OCTET STRING,
rlCLIremoteCLIcommandStatus RowStatus,
rlCLIremoteCLIactivationStatus INTEGER }
rlCLIremoteCLIcommandIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the command. The commands will be executed
in order of their indexes."
::= { rlCLIremoteCLIcommandsEntry 1 }
rlCLIremoteCLIcommandPartNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The part of the command. Long commands will be divided in
several parts, which will be concatenated before execution."
::= { rlCLIremoteCLIcommandsEntry 2 }
rlCLIremoteCLIcommandPart OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The text of the command part."
::= { rlCLIremoteCLIcommandsEntry 3 }
rlCLIremoteCLIcommandStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this entry."
::= { rlCLIremoteCLIcommandsEntry 4 }
rlCLIremoteCLIactivationStatus OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Activation status of the command. Any value greater than 0
indicates that the command has been activated and failed"
::= { rlCLIremoteCLIcommandsEntry 5 }
--- rlCLIremoteCLIoutputsTable
rlCLIremoteCLIoutputsTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlCLIremoteCLIoutputsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of CLI output rows."
::= { rlCLIremoteCLIsupport 6 }
rlCLIremoteCLIoutputsEntry OBJECT-TYPE
SYNTAX RlCLIremoteCLIoutputsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing a part of a CLI output row."
INDEX { rlCLIremoteCLIoutputRowIndex,
rlCLIremoteCLIoutputRowPartNumber }
::= { rlCLIremoteCLIoutputsTable 1 }
RlCLIremoteCLIoutputsEntry ::=
SEQUENCE { rlCLIremoteCLIoutputRowIndex Unsigned32 (1..4294967295),
rlCLIremoteCLIoutputRowPartNumber Unsigned32 (1..4294967295),
rlCLIremoteCLIoutputRowPart OCTET STRING,
rlCLIremoteCLIoutputRowStatus RowStatus,
rlCLIremoteCLIoutputCommandNumber INTEGER }
rlCLIremoteCLIoutputRowIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the output row."
::= { rlCLIremoteCLIoutputsEntry 1 }
rlCLIremoteCLIoutputRowPartNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The part of the output row."
::= { rlCLIremoteCLIoutputsEntry 2 }
rlCLIremoteCLIoutputRowPart OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The text of the output row part."
::= { rlCLIremoteCLIoutputsEntry 3 }
rlCLIremoteCLIoutputRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of the command part. Only destroy will be accepted
as value for SET."
::= { rlCLIremoteCLIoutputsEntry 4 }
rlCLIremoteCLIoutputCommandNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The command index of the command whose activation generated thist output row."
::= { rlCLIremoteCLIoutputsEntry 5 }
rlCLIremoteCLIinstance OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The remote CLI instance. A value of 0xFFFFFFFF indicates that no instance
corresponding to the client was found."
::= { rlCLIremoteCLIsupport 7 }
END
|