1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
3928
3929
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
3944
3945
3946
3947
3948
3949
3950
3951
3952
3953
3954
3955
3956
3957
3958
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
3981
3982
3983
3984
3985
3986
3987
3988
3989
3990
3991
3992
3993
3994
3995
3996
3997
3998
3999
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
4032
4033
4034
4035
4036
4037
4038
4039
4040
4041
4042
4043
4044
4045
4046
4047
4048
4049
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063
4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
4092
4093
4094
4095
4096
4097
4098
4099
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
4128
4129
4130
4131
4132
4133
4134
4135
4136
4137
4138
4139
4140
4141
4142
4143
4144
4145
4146
4147
4148
4149
4150
4151
4152
4153
4154
4155
4156
4157
4158
4159
4160
4161
4162
4163
4164
4165
4166
4167
4168
4169
4170
4171
4172
4173
4174
4175
4176
4177
4178
4179
4180
4181
4182
4183
4184
4185
4186
4187
4188
4189
4190
4191
4192
4193
4194
4195
4196
4197
4198
4199
4200
4201
4202
4203
4204
4205
4206
4207
4208
4209
4210
4211
4212
4213
4214
4215
4216
4217
4218
4219
4220
4221
4222
4223
4224
4225
4226
4227
4228
4229
4230
4231
4232
4233
4234
4235
4236
4237
4238
4239
4240
4241
4242
4243
4244
4245
4246
4247
4248
4249
4250
4251
4252
4253
4254
4255
4256
4257
4258
4259
4260
4261
4262
4263
4264
4265
4266
4267
4268
4269
4270
4271
4272
4273
4274
4275
4276
4277
4278
4279
4280
4281
4282
4283
4284
4285
4286
4287
4288
4289
4290
4291
4292
4293
4294
4295
4296
4297
4298
4299
4300
4301
4302
4303
4304
4305
4306
4307
4308
4309
4310
4311
4312
4313
4314
4315
4316
4317
4318
4319
4320
4321
4322
4323
4324
4325
4326
4327
4328
4329
4330
4331
4332
4333
4334
4335
4336
4337
4338
4339
4340
4341
4342
4343
4344
4345
4346
4347
4348
4349
4350
4351
4352
4353
4354
4355
4356
4357
4358
4359
4360
4361
4362
4363
4364
4365
4366
4367
4368
4369
4370
4371
4372
4373
4374
4375
4376
4377
4378
4379
4380
4381
4382
4383
4384
4385
4386
4387
4388
4389
4390
4391
4392
4393
4394
4395
4396
4397
4398
4399
4400
4401
4402
4403
4404
4405
4406
4407
4408
4409
4410
4411
4412
4413
4414
4415
4416
4417
4418
4419
4420
4421
4422
4423
4424
4425
4426
4427
4428
4429
4430
4431
4432
4433
4434
4435
4436
4437
4438
4439
4440
4441
4442
4443
4444
4445
4446
4447
4448
4449
4450
4451
4452
4453
4454
4455
4456
4457
4458
4459
4460
4461
4462
4463
4464
4465
4466
4467
4468
4469
4470
4471
4472
4473
4474
4475
4476
4477
4478
4479
4480
4481
4482
4483
4484
4485
4486
4487
4488
4489
4490
4491
4492
4493
4494
4495
4496
4497
4498
4499
4500
4501
4502
4503
4504
4505
4506
4507
4508
4509
4510
4511
4512
4513
4514
4515
4516
4517
4518
4519
4520
4521
4522
4523
4524
4525
4526
4527
4528
4529
4530
4531
4532
4533
4534
4535
4536
4537
4538
4539
4540
4541
4542
4543
4544
4545
4546
4547
4548
4549
4550
4551
4552
4553
4554
4555
4556
4557
4558
4559
4560
4561
4562
4563
4564
4565
4566
4567
4568
4569
4570
4571
4572
4573
4574
4575
4576
4577
4578
4579
4580
4581
4582
4583
4584
4585
4586
4587
4588
4589
4590
4591
4592
4593
4594
4595
4596
4597
4598
4599
4600
4601
4602
4603
4604
4605
4606
4607
4608
4609
4610
4611
4612
4613
4614
4615
4616
4617
4618
4619
4620
4621
4622
4623
4624
4625
4626
4627
4628
4629
4630
4631
4632
4633
4634
4635
4636
4637
4638
4639
4640
4641
4642
4643
4644
4645
4646
4647
4648
4649
4650
4651
4652
4653
4654
4655
4656
4657
4658
4659
4660
4661
4662
4663
4664
4665
4666
4667
4668
4669
4670
4671
4672
4673
4674
4675
4676
4677
4678
4679
4680
4681
4682
4683
4684
4685
4686
4687
4688
4689
4690
4691
4692
4693
4694
4695
4696
4697
4698
4699
4700
4701
4702
4703
4704
4705
4706
4707
4708
4709
4710
4711
4712
4713
4714
4715
4716
4717
4718
4719
4720
4721
4722
4723
4724
4725
4726
4727
4728
4729
4730
4731
4732
4733
4734
4735
4736
4737
4738
4739
4740
4741
4742
4743
4744
4745
4746
4747
4748
4749
4750
4751
4752
4753
4754
4755
4756
4757
4758
4759
4760
4761
4762
4763
4764
4765
4766
4767
4768
4769
4770
4771
4772
4773
4774
4775
4776
4777
4778
4779
4780
4781
4782
4783
4784
4785
4786
4787
4788
4789
4790
4791
4792
4793
4794
4795
4796
4797
4798
4799
4800
4801
4802
4803
4804
4805
4806
4807
4808
4809
4810
4811
4812
4813
4814
4815
4816
4817
4818
4819
4820
4821
4822
4823
4824
4825
4826
4827
4828
4829
4830
4831
4832
4833
4834
4835
4836
4837
4838
4839
4840
4841
4842
4843
4844
4845
4846
4847
4848
4849
4850
4851
4852
4853
4854
4855
4856
4857
4858
4859
4860
4861
4862
4863
4864
4865
4866
4867
4868
4869
4870
4871
4872
4873
4874
4875
4876
4877
4878
4879
4880
4881
4882
4883
4884
4885
4886
4887
4888
4889
4890
4891
4892
4893
4894
4895
4896
4897
4898
4899
4900
4901
4902
4903
4904
4905
4906
4907
4908
4909
4910
4911
4912
4913
4914
4915
4916
4917
4918
4919
4920
4921
4922
4923
4924
4925
4926
4927
4928
4929
4930
4931
4932
4933
4934
4935
4936
4937
4938
4939
4940
4941
4942
4943
4944
4945
4946
4947
4948
4949
4950
4951
4952
4953
4954
4955
4956
4957
4958
4959
4960
4961
4962
4963
4964
4965
4966
4967
4968
4969
4970
4971
4972
4973
4974
4975
4976
4977
4978
4979
4980
4981
4982
4983
4984
4985
4986
4987
4988
4989
4990
4991
4992
4993
4994
4995
4996
4997
4998
4999
5000
5001
5002
5003
5004
5005
5006
5007
5008
5009
5010
5011
5012
5013
5014
5015
5016
5017
5018
5019
5020
5021
5022
5023
5024
5025
5026
5027
5028
5029
5030
5031
5032
5033
5034
5035
5036
5037
5038
5039
5040
5041
5042
5043
5044
5045
5046
5047
5048
5049
5050
5051
5052
5053
5054
5055
5056
5057
5058
5059
5060
5061
5062
5063
5064
5065
5066
5067
5068
5069
5070
5071
5072
5073
5074
5075
5076
5077
5078
5079
5080
5081
5082
5083
5084
5085
5086
5087
5088
5089
5090
5091
5092
5093
5094
5095
5096
5097
5098
5099
5100
5101
5102
5103
5104
5105
5106
5107
5108
5109
5110
5111
5112
5113
5114
5115
5116
5117
5118
5119
5120
5121
5122
5123
5124
5125
5126
5127
5128
5129
5130
5131
5132
5133
5134
5135
5136
5137
5138
5139
5140
5141
5142
5143
5144
5145
5146
5147
5148
5149
5150
5151
5152
5153
5154
5155
5156
5157
5158
5159
5160
5161
5162
5163
5164
5165
5166
5167
5168
5169
5170
5171
5172
5173
5174
5175
5176
5177
5178
5179
5180
5181
5182
5183
5184
5185
5186
5187
5188
5189
5190
5191
5192
5193
5194
5195
5196
5197
5198
5199
5200
5201
5202
5203
5204
5205
5206
5207
5208
5209
5210
5211
5212
5213
5214
5215
5216
5217
5218
5219
5220
5221
5222
5223
5224
5225
5226
5227
5228
5229
5230
5231
5232
5233
5234
5235
5236
5237
5238
5239
5240
5241
5242
5243
5244
5245
5246
5247
5248
5249
5250
5251
5252
5253
5254
5255
5256
5257
5258
5259
5260
5261
5262
5263
5264
5265
5266
5267
5268
5269
5270
5271
5272
5273
5274
5275
5276
5277
5278
5279
5280
5281
5282
5283
5284
5285
5286
5287
5288
5289
5290
5291
5292
5293
5294
5295
5296
5297
5298
5299
5300
5301
5302
5303
5304
5305
5306
5307
5308
5309
5310
5311
5312
5313
5314
5315
5316
5317
5318
5319
5320
5321
5322
5323
5324
5325
5326
5327
5328
5329
5330
5331
5332
5333
5334
5335
5336
5337
5338
5339
5340
5341
5342
5343
5344
5345
5346
5347
5348
5349
5350
5351
5352
5353
5354
5355
5356
5357
5358
5359
5360
5361
5362
5363
5364
5365
5366
5367
5368
5369
5370
5371
5372
5373
5374
5375
5376
5377
5378
5379
5380
5381
5382
5383
5384
5385
5386
5387
5388
5389
5390
5391
5392
5393
5394
5395
5396
5397
5398
5399
5400
5401
5402
5403
5404
5405
5406
5407
5408
5409
5410
5411
5412
5413
5414
5415
5416
5417
5418
5419
5420
5421
5422
5423
5424
5425
5426
5427
5428
5429
5430
5431
5432
5433
5434
5435
5436
5437
5438
5439
5440
5441
5442
5443
5444
5445
5446
5447
5448
5449
5450
5451
5452
5453
5454
5455
5456
5457
5458
5459
5460
5461
5462
5463
5464
5465
5466
5467
5468
5469
5470
5471
5472
5473
5474
5475
5476
5477
5478
5479
5480
5481
5482
5483
5484
5485
5486
5487
5488
5489
5490
5491
5492
5493
5494
5495
5496
5497
5498
5499
5500
5501
5502
5503
5504
5505
5506
5507
5508
5509
5510
5511
5512
5513
5514
5515
5516
5517
5518
5519
5520
5521
5522
5523
5524
5525
5526
5527
5528
5529
5530
5531
5532
5533
5534
|
LIEBERT-GP-FLEXIBLE-CONDITIONS-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-IDENTITY
FROM SNMPv2-SMI
liebertFlexibleConditionsModuleReg
FROM LIEBERT-GP-REGISTRATION-MIB
lgpFlexConditions
FROM LIEBERT-GP-CONDITIONS-MIB
;
-- =============================================================================
-- Module Identification and Registration
-- =============================================================================
liebertGlobalProductsFlexibleConditionsModule MODULE-IDENTITY
LAST-UPDATED "201810020000Z"
ORGANIZATION "Liebert Corporation"
CONTACT-INFO
"Contact: Technical Support
Postal:
Liebert Corporation
1050 Dearborn Drive
P.O. Box 29186
Columbus OH, 43229
US
Tel: +1 (800) 222-5877
E-mail: liebert.monitoring@vertivco.com
Web: www.vertivco.com"
DESCRIPTION
"The MIB module used to register Liebert SNMP OIDs.
Copyright 2000-2018 Liebert Corporation. All rights reserved.
Reproduction of this document is authorized on the condition
that the forgoing copyright notice is included.
This Specification is supplied 'AS IS' and Liebert Corporation
makes no warranty, either express or implied, as to the use,
operation, condition, or performance of the Specification."
REVISION "201810020000Z"
DESCRIPTION
"Compiled From GDD Version: 6825.1"
::= { liebertFlexibleConditionsModuleReg 1 }
-- =============================================================================
-- lgpFlexConditions - Liebert Conditions Registrations
-- =============================================================================
lgpFlexConditionsWellKnown OBJECT IDENTIFIER
-- STATUS current
-- DESCRIPTION
-- "Liebert well known conditions are defined by OIDs that
-- reside in this sub-tree."
::= { lgpFlexConditions 1 }
-- =============================================================================
-- lgpFlexConditionsWellKnown - Liebert "well-known" Conditions
-- =============================================================================
lgpCondId4122SystemInputPowerProblem OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The input is not qualified to provide power to the system."
::= { lgpFlexConditionsWellKnown 4122 }
lgpCondId4132BypassOverloadPhaseA OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An overload exists on output phase A while operating on the bypass."
::= { lgpFlexConditionsWellKnown 4132 }
lgpCondId4133BypassOverloadPhaseB OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An overload exists on output phase B while operating on the bypass."
::= { lgpFlexConditionsWellKnown 4133 }
lgpCondId4134BypassOverloadPhaseC OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An overload exists on output phase C while operating on the bypass."
::= { lgpFlexConditionsWellKnown 4134 }
lgpCondId4135BypassNotAvailable OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A problem associated with the bypass has been detected."
::= { lgpFlexConditionsWellKnown 4135 }
lgpCondId4137BypassAutoRetransferPrimed OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Automatic retransfer from bypass to inverter is possible."
::= { lgpFlexConditionsWellKnown 4137 }
lgpCondId4138BypassAutoRetransferFailed OBJECT-IDENTITY
STATUS current
DESCRIPTION
"After performing a recoverable transfer to bypass, an attempt to
auto retransfer from bypass to inverter failed."
::= { lgpFlexConditionsWellKnown 4138 }
lgpCondId4139BypassExcessAutoRetransfers OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The number of auto retransfers, from bypass to inverter, has
exceeded the maximum for a specified time interval."
::= { lgpFlexConditionsWellKnown 4139 }
lgpCondId4140BypassRestartInhibitExternal OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Restart of the bypass is inhibited by the state of an external
signal."
::= { lgpFlexConditionsWellKnown 4140 }
lgpCondId4141BypassBreakerClosed OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The bypass breaker is closed."
::= { lgpFlexConditionsWellKnown 4141 }
lgpCondId4142BypassStaticSwitchOverload OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Bypass off due to static switch overload."
::= { lgpFlexConditionsWellKnown 4142 }
lgpCondId4143BypassStaticSwitchUnavailable OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The static bypass is unavailable to support the critical load."
::= { lgpFlexConditionsWellKnown 4143 }
lgpCondId4144BypassExcessivePulseParallel OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has performed too many pulse parallel operations within
a specified time interval."
::= { lgpFlexConditionsWellKnown 4144 }
lgpCondId4145BypassAutoTransferFailed OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An automatic transfer to static bypass failed."
::= { lgpFlexConditionsWellKnown 4145 }
lgpCondId4146SystemInputPhsRotationError OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The power conductors on the input line are not wired to the UPS in
the sequence preferred for the rectifier (A-B-C)."
::= { lgpFlexConditionsWellKnown 4146 }
lgpCondId4147SystemInputCurrentLimit OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The RMS input current has reached the input current limit
threshold."
::= { lgpFlexConditionsWellKnown 4147 }
lgpCondId4162BatteryLow OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The calculated battery time remaining has reached the low battery
threshold."
::= { lgpFlexConditionsWellKnown 4162 }
lgpCondId4163OutputOffEndofDischarge OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Output turned off due to battery reaching end-of-discharge."
::= { lgpFlexConditionsWellKnown 4163 }
lgpCondId4164BatteryChargingError OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The battery is not charging properly."
::= { lgpFlexConditionsWellKnown 4164 }
lgpCondId4165BatteryChargingReducedExtrnl OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Using a reduced battery charging algorithm due to an external
signal."
::= { lgpFlexConditionsWellKnown 4165 }
lgpCondId4166BatteryCapacityLow OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery capacity is low."
::= { lgpFlexConditionsWellKnown 4166 }
lgpCondId4167OutputOff OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Output is off."
::= { lgpFlexConditionsWellKnown 4167 }
lgpCondId4168BatteryDischarging OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The battery is discharging."
::= { lgpFlexConditionsWellKnown 4168 }
lgpCondId4169BatteryTemperatureImbalance OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Excessive temperature differences between battery sensors detected."
::= { lgpFlexConditionsWellKnown 4169 }
lgpCondId4170BatteryEqualize OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The rectifier output voltage is increased to equalize the battery
voltage level."
::= { lgpFlexConditionsWellKnown 4170 }
lgpCondId4171BatteryManualTestInProgress OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Manual battery test is in progress."
::= { lgpFlexConditionsWellKnown 4171 }
lgpCondId4172BatteryAutoTestInProgress OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Automatic battery test is in progress."
::= { lgpFlexConditionsWellKnown 4172 }
lgpCondId4173MainBatteryDisconnectOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Main battery disconnect is open."
::= { lgpFlexConditionsWellKnown 4173 }
lgpCondId4174BatteryTemperatureSensorFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A battery temperature sensor fault has been detected."
::= { lgpFlexConditionsWellKnown 4174 }
lgpCondId4175BypassFrequencyError OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The bypass frequency is outside the inverter synchronization
limits."
::= { lgpFlexConditionsWellKnown 4175 }
lgpCondId4176BatteryCircuitBreaker1Open OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 1 is open."
::= { lgpFlexConditionsWellKnown 4176 }
lgpCondId4177BatteryBreaker1OpenFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 1 failed to open."
::= { lgpFlexConditionsWellKnown 4177 }
lgpCondId4178BatteryBreaker1CloseFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 1 failed to close."
::= { lgpFlexConditionsWellKnown 4178 }
lgpCondId4179BatteryCircuitBreaker2Open OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 2 is open."
::= { lgpFlexConditionsWellKnown 4179 }
lgpCondId4180BatteryBreaker2OpenFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 2 failed to open."
::= { lgpFlexConditionsWellKnown 4180 }
lgpCondId4181BatteryBreaker2CloseFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 2 failed to close."
::= { lgpFlexConditionsWellKnown 4181 }
lgpCondId4182BatteryCircuitBreaker3Open OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 3 is open."
::= { lgpFlexConditionsWellKnown 4182 }
lgpCondId4183BatteryBreaker3OpenFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 3 failed to open."
::= { lgpFlexConditionsWellKnown 4183 }
lgpCondId4184BatteryBreaker3CloseFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 3 failed to close."
::= { lgpFlexConditionsWellKnown 4184 }
lgpCondId4185BatteryCircuitBreaker4Open OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 4 is open."
::= { lgpFlexConditionsWellKnown 4185 }
lgpCondId4186BatteryBreaker4OpenFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 4 failed to open."
::= { lgpFlexConditionsWellKnown 4186 }
lgpCondId4187BatteryBreaker4CloseFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 4 failed to close."
::= { lgpFlexConditionsWellKnown 4187 }
lgpCondId4188BatteryCircuitBreaker5Open OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 5 is open."
::= { lgpFlexConditionsWellKnown 4188 }
lgpCondId4189BatteryBreaker5OpenFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 5 failed to open."
::= { lgpFlexConditionsWellKnown 4189 }
lgpCondId4190BatteryBreaker5CloseFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 5 failed to close."
::= { lgpFlexConditionsWellKnown 4190 }
lgpCondId4191BatteryCircuitBreaker6Open OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 6 is open."
::= { lgpFlexConditionsWellKnown 4191 }
lgpCondId4192BatteryBreaker6OpenFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 6 failed to open."
::= { lgpFlexConditionsWellKnown 4192 }
lgpCondId4193BatteryBreaker6CloseFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 6 failed to close."
::= { lgpFlexConditionsWellKnown 4193 }
lgpCondId4194BatteryCircuitBreaker7Open OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 7 is open."
::= { lgpFlexConditionsWellKnown 4194 }
lgpCondId4195BatteryBreaker7OpenFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 7 failed to open."
::= { lgpFlexConditionsWellKnown 4195 }
lgpCondId4196BatteryBreaker7CloseFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 7 failed to close."
::= { lgpFlexConditionsWellKnown 4196 }
lgpCondId4197BatteryCircuitBreaker8Open OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 8 is open."
::= { lgpFlexConditionsWellKnown 4197 }
lgpCondId4198BatteryBreaker8OpenFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 8 failed to open."
::= { lgpFlexConditionsWellKnown 4198 }
lgpCondId4199BatteryBreaker8CloseFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery circuit breaker 8 failed to close."
::= { lgpFlexConditionsWellKnown 4199 }
lgpCondId4200BatteryChargingInhibited OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery charging is inhibited due to an external inhibit signal."
::= { lgpFlexConditionsWellKnown 4200 }
lgpCondId4213SystemShutdownEPO OBJECT-IDENTITY
STATUS current
DESCRIPTION
"System shutdown due to Emergency Power Off (EPO)."
::= { lgpFlexConditionsWellKnown 4213 }
lgpCondId4214SystemShutdownREPO OBJECT-IDENTITY
STATUS current
DESCRIPTION
"System shutdown due to Remote Emergency Power Off (REPO)."
::= { lgpFlexConditionsWellKnown 4214 }
lgpCondId4215SystemOutputOff OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system output is off."
::= { lgpFlexConditionsWellKnown 4215 }
lgpCondId4216BypassBackfeedDetected OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system detected a voltage on the bypass when none was expected."
::= { lgpFlexConditionsWellKnown 4216 }
lgpCondId4217BypassManualXfrInhibited OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Manual transfer from inverter to bypass is inhibited - bypass not
qualified."
::= { lgpFlexConditionsWellKnown 4217 }
lgpCondId4218BypassManualRexfrInhibited OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Manual transfer from bypass to inverter is inhibited - inverter
output not qualified."
::= { lgpFlexConditionsWellKnown 4218 }
lgpCondId4219BatteryOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A battery temperature sensor is reporting a value above a
threshold."
::= { lgpFlexConditionsWellKnown 4219 }
lgpCondId4220BatteryExternalMonitor1 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"External battery monitor 1 - battery maintenance required."
::= { lgpFlexConditionsWellKnown 4220 }
lgpCondId4221BatteryExternalMonitor2 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"External battery monitor 2 - battery maintenance required."
::= { lgpFlexConditionsWellKnown 4221 }
lgpCondId4222BatteryGroundFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery system ground fault amperage exceeds the threshold."
::= { lgpFlexConditionsWellKnown 4222 }
lgpCondId4229EmergencyPowerOffLatched OBJECT-IDENTITY
STATUS current
DESCRIPTION
"System output is off - 'Emergency Power Off (EPO) - latched'
requires manual reset."
::= { lgpFlexConditionsWellKnown 4229 }
lgpCondId4230SystemOutputLowPowerFactor OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system output power factor is low, resulting in reduced output
capacity."
::= { lgpFlexConditionsWellKnown 4230 }
lgpCondId4231OutputCurrentExceedsThreshold OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Output current for one or more phases exceeds a threshold."
::= { lgpFlexConditionsWellKnown 4231 }
lgpCondId4233InverterFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Inverter failure - inverter output is off."
::= { lgpFlexConditionsWellKnown 4233 }
lgpCondId4234InverterOverloadPhaseA OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Inverter is operating with an overload on phase A."
::= { lgpFlexConditionsWellKnown 4234 }
lgpCondId4235InverterOverloadPhaseB OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Inverter is operating with an overload on phase B."
::= { lgpFlexConditionsWellKnown 4235 }
lgpCondId4236InverterOverloadPhaseC OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Inverter is operating with an overload on phase C."
::= { lgpFlexConditionsWellKnown 4236 }
lgpCondId4237InverterInhibitExternal OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Restart of the inverter is inhibited by an external signal."
::= { lgpFlexConditionsWellKnown 4237 }
lgpCondId4238InverterOutBreakerOpenFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Inverter output breaker failed to open."
::= { lgpFlexConditionsWellKnown 4238 }
lgpCondId4239InverterOutBreakerCloseFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Inverter output breaker failed to close."
::= { lgpFlexConditionsWellKnown 4239 }
lgpCondId4270InputContact01 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external input contact 1."
::= { lgpFlexConditionsWellKnown 4270 }
lgpCondId4271InputContact02 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external input contact 2."
::= { lgpFlexConditionsWellKnown 4271 }
lgpCondId4272InputContact03 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external input contact 3."
::= { lgpFlexConditionsWellKnown 4272 }
lgpCondId4273InputContact04 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external input contact 4."
::= { lgpFlexConditionsWellKnown 4273 }
lgpCondId4274InputContact05 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external input contact 5."
::= { lgpFlexConditionsWellKnown 4274 }
lgpCondId4275InputContact06 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external input contact 6."
::= { lgpFlexConditionsWellKnown 4275 }
lgpCondId4276InputContact07 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external input contact 7."
::= { lgpFlexConditionsWellKnown 4276 }
lgpCondId4277InputContact08 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external input contact 8."
::= { lgpFlexConditionsWellKnown 4277 }
lgpCondId4278InputContact09 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external input contact 9."
::= { lgpFlexConditionsWellKnown 4278 }
lgpCondId4279InputContact10 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external input contact 10."
::= { lgpFlexConditionsWellKnown 4279 }
lgpCondId4280InputContact11 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external input contact 11."
::= { lgpFlexConditionsWellKnown 4280 }
lgpCondId4281InputContact12 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external input contact 12."
::= { lgpFlexConditionsWellKnown 4281 }
lgpCondId4282InputContact13 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external input contact 13."
::= { lgpFlexConditionsWellKnown 4282 }
lgpCondId4283InputContact14 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external input contact 14."
::= { lgpFlexConditionsWellKnown 4283 }
lgpCondId4284InputContact15 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external input contact 15."
::= { lgpFlexConditionsWellKnown 4284 }
lgpCondId4285InputContact16 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external input contact 16."
::= { lgpFlexConditionsWellKnown 4285 }
lgpCondId4286OutputAmpOverUserLimitPhsA OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The phase A output has exceeded the user amperage threshold."
::= { lgpFlexConditionsWellKnown 4286 }
lgpCondId4287OutputAmpOverUserLimitPhsB OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The phase B output has exceeded the user amperage threshold."
::= { lgpFlexConditionsWellKnown 4287 }
lgpCondId4288OutputAmpOverUserLimitPhsC OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The phase C output has exceeded the user amperage threshold."
::= { lgpFlexConditionsWellKnown 4288 }
lgpCondId4289InverterTransferInhibitExt OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Transfer of critical bus source to inverter is inhibited by an
external signal."
::= { lgpFlexConditionsWellKnown 4289 }
lgpCondId4290InverterShutdownOverload OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The inverter has shutdown due to a sustained overload."
::= { lgpFlexConditionsWellKnown 4290 }
lgpCondId4294InletAirOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The inlet air exceeds the maximum temperature threshold."
::= { lgpFlexConditionsWellKnown 4294 }
lgpCondId4295RectifierFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Rectifier failure - rectifier is off."
::= { lgpFlexConditionsWellKnown 4295 }
lgpCondId4296RectifierOperationInhibitExt OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The operation of the rectifier is inhibited by an external signal."
::= { lgpFlexConditionsWellKnown 4296 }
lgpCondId4297UPSOutputonInverter OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The output power is supplied by the inverter."
::= { lgpFlexConditionsWellKnown 4297 }
lgpCondId4298UPSOutputonBypass OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The output power is supplied by the bypass."
::= { lgpFlexConditionsWellKnown 4298 }
lgpCondId4299OutputLoadonMaintBypass OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The output power is supplied by the maintenance bypass."
::= { lgpFlexConditionsWellKnown 4299 }
lgpCondId4300InternalCommunicationsFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The control has detected a communication failure of a component on
the internal communication bus."
::= { lgpFlexConditionsWellKnown 4300 }
lgpCondId4308DCBusGroundFaultPositive OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A ground fault has been detected on the positive DC Bus link."
::= { lgpFlexConditionsWellKnown 4308 }
lgpCondId4309DCBusGroundFaultNegative OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A ground fault has been detected on the negative DC Bus link."
::= { lgpFlexConditionsWellKnown 4309 }
lgpCondId4310EquipmentOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Equipment over temperature summary event."
::= { lgpFlexConditionsWellKnown 4310 }
lgpCondId4311SystemFanFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"System fan failure - one or more fans have failed."
::= { lgpFlexConditionsWellKnown 4311 }
lgpCondId4313PasswordChanged OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Password changed."
::= { lgpFlexConditionsWellKnown 4313 }
lgpCondId4314PowerSupplyFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Power supply failure."
::= { lgpFlexConditionsWellKnown 4314 }
lgpCondId4315OnGenerator OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A generator is supplying the power to the system."
::= { lgpFlexConditionsWellKnown 4315 }
lgpCondId4316AutoRestartInProgress OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Auto restart is in progress."
::= { lgpFlexConditionsWellKnown 4316 }
lgpCondId4317AutoRestartInhibitedExt OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Auto restart inhibited due to an external signal."
::= { lgpFlexConditionsWellKnown 4317 }
lgpCondId4320InitiatedTransfertoBypass OBJECT-IDENTITY
STATUS current
DESCRIPTION
"User initiated manual transfer to bypass."
::= { lgpFlexConditionsWellKnown 4320 }
lgpCondId4321InitiatedTransfertoInverter OBJECT-IDENTITY
STATUS current
DESCRIPTION
"User initiated manual transfer to inverter."
::= { lgpFlexConditionsWellKnown 4321 }
lgpCondId4322BatteryTestPassed OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery test passed."
::= { lgpFlexConditionsWellKnown 4322 }
lgpCondId4323BatteryTestFailed OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery test failed."
::= { lgpFlexConditionsWellKnown 4323 }
lgpCondId4324BatteryTestManuallyStopped OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The battery test was manually stopped prior to completion."
::= { lgpFlexConditionsWellKnown 4324 }
lgpCondId4325BackfeedBreakerOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The backfeed breaker is in the open position."
::= { lgpFlexConditionsWellKnown 4325 }
lgpCondId4341VelocityAuthenticationFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notification of a message rejected by Velocity due to an
authentication failure."
::= { lgpFlexConditionsWellKnown 4341 }
lgpCondId4360ReceptacleOverCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a receptacle over current condition."
::= { lgpFlexConditionsWellKnown 4360 }
lgpCondId4361ReceptacleUnderCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a receptacle under current condition."
::= { lgpFlexConditionsWellKnown 4361 }
lgpCondId4382SystemInputCurrentImbalance OBJECT-IDENTITY
STATUS current
DESCRIPTION
"System Input Currents are Imbalanced."
::= { lgpFlexConditionsWellKnown 4382 }
lgpCondId4383BypassStaticSwitchOffExtrnl OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Bypass static switch is off due to the state of an external signal."
::= { lgpFlexConditionsWellKnown 4383 }
lgpCondId4384BatteryEoDDisconnect OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery disconnect due to end-of-discharge."
::= { lgpFlexConditionsWellKnown 4384 }
lgpCondId4389SystemOutputFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A fault has been detected in the system output."
::= { lgpFlexConditionsWellKnown 4389 }
lgpCondId4390InverterOffExternal OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Inverter is off (operation is inhibited) due to external signal
state."
::= { lgpFlexConditionsWellKnown 4390 }
lgpCondId4391InverterStaticSwitchSCRShort OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a short across one or more inverter static
switch Silicon Controlled Rectifiers (SCR)."
::= { lgpFlexConditionsWellKnown 4391 }
lgpCondId4392TemperatureSensorError OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more temperature sensors cannot provide a valid temperature
reading (i.e. sensor failure, wiring failure, sense circuit
failure, etc)."
::= { lgpFlexConditionsWellKnown 4392 }
lgpCondId4406BranchOverCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module over current condition."
::= { lgpFlexConditionsWellKnown 4406 }
lgpCondId4407BranchUnderCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module under current condition."
::= { lgpFlexConditionsWellKnown 4407 }
lgpCondId4416BranchOverCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module over current condition."
::= { lgpFlexConditionsWellKnown 4416 }
lgpCondId4417BranchUnderCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module under current condition."
::= { lgpFlexConditionsWellKnown 4417 }
lgpCondId4421BranchFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more conditions indicate a Branch Receptacle Module failure
, service is required."
::= { lgpFlexConditionsWellKnown 4421 }
lgpCondId4436PDUOverCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module over current condition."
::= { lgpFlexConditionsWellKnown 4436 }
lgpCondId4437PDUUnderCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module under current condition."
::= { lgpFlexConditionsWellKnown 4437 }
lgpCondId4438SystemInternalTemperatureRise OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Excessive temperature rise internal to the system (i.e. difference
between the output versus input temperature is too large)."
::= { lgpFlexConditionsWellKnown 4438 }
lgpCondId4439AutomaticRestartFailed OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Automatic restart failed."
::= { lgpFlexConditionsWellKnown 4439 }
lgpCondId4440FuseFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A summary event indicating one or more fuse failures."
::= { lgpFlexConditionsWellKnown 4440 }
lgpCondId4441SystemControllerError OBJECT-IDENTITY
STATUS current
DESCRIPTION
"System controller internal error."
::= { lgpFlexConditionsWellKnown 4441 }
lgpCondId4442SystemBreakersOpenFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more breakers in the system failed to open."
::= { lgpFlexConditionsWellKnown 4442 }
lgpCondId4448PDUOverCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module over current condition."
::= { lgpFlexConditionsWellKnown 4448 }
lgpCondId4449PDUUnderCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module under current condition."
::= { lgpFlexConditionsWellKnown 4449 }
lgpCondId4468PDUOverCurrentL1 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module over current condition on line 1."
::= { lgpFlexConditionsWellKnown 4468 }
lgpCondId4469PDUOverCurrentL2 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module over current condition on line 2."
::= { lgpFlexConditionsWellKnown 4469 }
lgpCondId4470PDUOverCurrentL3 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module over current condition on line 3."
::= { lgpFlexConditionsWellKnown 4470 }
lgpCondId4471PDUUnderCurrentL1 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module under current condition on line 1."
::= { lgpFlexConditionsWellKnown 4471 }
lgpCondId4472PDUUnderCurrentL2 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module under current condition on line 2."
::= { lgpFlexConditionsWellKnown 4472 }
lgpCondId4473PDUUnderCurrentL3 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module under current condition on line 3."
::= { lgpFlexConditionsWellKnown 4473 }
lgpCondId4492ReceptaclePowerStateOn OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The receptacle power state changed to the ON state."
::= { lgpFlexConditionsWellKnown 4492 }
lgpCondId4493ReceptaclePowerStateOff OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The receptacle power state changed to the OFF state."
::= { lgpFlexConditionsWellKnown 4493 }
lgpCondId4494BranchBreakerOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Branch Receptacle Module's input breaker is open."
::= { lgpFlexConditionsWellKnown 4494 }
lgpCondId4495DeviceConfigurationChange OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Device Configuration Change."
::= { lgpFlexConditionsWellKnown 4495 }
lgpCondId4496BasicDisplayModuleRemoved OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Basic Display Module Removed."
::= { lgpFlexConditionsWellKnown 4496 }
lgpCondId4497BasicDisplayModuleDiscovered OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Basic Display Module Discovered."
::= { lgpFlexConditionsWellKnown 4497 }
lgpCondId4500PDUOverCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a power module over current condition."
::= { lgpFlexConditionsWellKnown 4500 }
lgpCondId4501PDUUnderCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a power module under current condition."
::= { lgpFlexConditionsWellKnown 4501 }
lgpCondId4502PDUFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more conditions indicate a power module failure, service is
required."
::= { lgpFlexConditionsWellKnown 4502 }
lgpCondId4503PDUCommunicationFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Internal communications failure with the Power Module."
::= { lgpFlexConditionsWellKnown 4503 }
lgpCondId4504BranchRemoved OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Branch Receptacle Module Removed."
::= { lgpFlexConditionsWellKnown 4504 }
lgpCondId4505BranchDiscovered OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Branch Receptacle Module Discovered."
::= { lgpFlexConditionsWellKnown 4505 }
lgpCondId4506BranchOverCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a Branch Receptacle Module over current
condition."
::= { lgpFlexConditionsWellKnown 4506 }
lgpCondId4507BranchCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a Branch Receptacle Module under current
condition."
::= { lgpFlexConditionsWellKnown 4507 }
lgpCondId4508ReceptacleLoadRemoved OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The receptacle's load stopped drawing power."
::= { lgpFlexConditionsWellKnown 4508 }
lgpCondId4509ReceptacleLoadAdded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The receptacle's load started to draw power."
::= { lgpFlexConditionsWellKnown 4509 }
lgpCondId4523ModuleRemoved OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Module Removed."
::= { lgpFlexConditionsWellKnown 4523 }
lgpCondId4524ModuleAdded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Module Added."
::= { lgpFlexConditionsWellKnown 4524 }
lgpCondId4550FirmwareUpdateRequired OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Module compatibility error requires a system firmware update to
resolve."
::= { lgpFlexConditionsWellKnown 4550 }
lgpCondId4551GenericTestEvent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A generic test event designed to evaluate system handling of
events."
::= { lgpFlexConditionsWellKnown 4551 }
lgpCondId4580OverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An over temperature condition was detected."
::= { lgpFlexConditionsWellKnown 4580 }
lgpCondId4581UnderTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An under temperature condition was detected."
::= { lgpFlexConditionsWellKnown 4581 }
lgpCondId4588OverRelativeHumidity OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An over relative humidity condition was detected."
::= { lgpFlexConditionsWellKnown 4588 }
lgpCondId4589UnderRelativeHumidity OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An under relative humidity condition was detected."
::= { lgpFlexConditionsWellKnown 4589 }
lgpCondId4601ExternalAirSensorAOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Ext Air Sensor A Temperature] has exceeded [External Air Over
Temp Threshold]."
::= { lgpFlexConditionsWellKnown 4601 }
lgpCondId4604ExternalAirSensorBOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Ext Air Sensor B Temperature] has exceeded [External Air Over
Temp Threshold]."
::= { lgpFlexConditionsWellKnown 4604 }
lgpCondId4608ExtAirSensorAUnderTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Ext Air Sensor A Temperature] has dropped below [Ext Air Under
Temp Threshold]."
::= { lgpFlexConditionsWellKnown 4608 }
lgpCondId4611ExtAirSensorBUnderTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Ext Air Sensor B Temperature] has dropped below [Ext Air Under
Temp Threshold]."
::= { lgpFlexConditionsWellKnown 4611 }
lgpCondId4615ExtDewPointOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"At least one dew point temperature reading ([Ext Air Sensor A Dew
Point Temp], [Ext Air Sensor B Dew Point Temp]...) has exceeded
[Ext Dew Point Over Temp Threshold]."
::= { lgpFlexConditionsWellKnown 4615 }
lgpCondId4618ExternalAirSensorAIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external air sensor A is disconnected or the signal is out of
range."
::= { lgpFlexConditionsWellKnown 4618 }
lgpCondId4621ExternalAirSensorBIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external air sensor B is disconnected or the signal is out of
range."
::= { lgpFlexConditionsWellKnown 4621 }
lgpCondId4626SupplyChilledWaterOverTemp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Supply Fluid Temperature] has exceeded [High Supply Fluid
Temperature Threshold]."
::= { lgpFlexConditionsWellKnown 4626 }
lgpCondId4629SupplyChilledWaterTempSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The supply chilled water temperature sensor is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 4629 }
lgpCondId4634SupplyRefrigerantOverTemp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Event that is activated when [Supply Refrigerant Temperature]
exceeds [Supply Refrig Over Temp Threshold]. The event is
deactivated when the temperature drops below the threshold."
::= { lgpFlexConditionsWellKnown 4634 }
lgpCondId4637SupplyRefrigerantUnderTemp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Supply Refrigerant Temperature] has dropped below a specified
threshold."
::= { lgpFlexConditionsWellKnown 4637 }
lgpCondId4640SupplyRefrigerantTempSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The supply refrigeramt temperature sensor is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 4640 }
lgpCondId4645SupplyFluidOverTemp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Supply Fluid Temperature] has exceeded [Supply Fluid Over Temp
Threshold]."
::= { lgpFlexConditionsWellKnown 4645 }
lgpCondId4648SupplyFluidUnderTemp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Supply Fluid Temperature] has dropped below a specified threshold."
::= { lgpFlexConditionsWellKnown 4648 }
lgpCondId4651SupplyFluidTempSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The supply fluid temperature sensor is disconnected or the signal
is out of range."
::= { lgpFlexConditionsWellKnown 4651 }
lgpCondId4656Pump1LossofFlow OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Loss of flow is detected in pump 1. The loss of flow condition
occurs when no differential pressure is detected across the pump."
::= { lgpFlexConditionsWellKnown 4656 }
lgpCondId4659Pump2LossofFlow OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Loss of flow is detected in pump 2. The loss of flow condition
occurs when no differential pressure is detected across the pump."
::= { lgpFlexConditionsWellKnown 4659 }
lgpCondId4662PumpShortCycle OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Pumps have short cycled. A short cycle is defined as turning on
and off a number of times over a set time period."
::= { lgpFlexConditionsWellKnown 4662 }
lgpCondId4669Compressor1AHighHeadPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor 1A high head pressure."
::= { lgpFlexConditionsWellKnown 4669 }
lgpCondId4672Compressor1BHighHeadPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor 1B high head pressure."
::= { lgpFlexConditionsWellKnown 4672 }
lgpCondId4675Compressor2AHighHeadPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor 2A high head pressure."
::= { lgpFlexConditionsWellKnown 4675 }
lgpCondId4678Compressor2BHighHeadPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor 2B high head pressure."
::= { lgpFlexConditionsWellKnown 4678 }
lgpCondId4681Compressor1AShortCycle OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor 1A short cycle. A short cycle is defined as turning on
and off a number of times over a set time period."
::= { lgpFlexConditionsWellKnown 4681 }
lgpCondId4684Compressor1BShortCycle OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor 1B short cycle. A short cycle is defined as turning on
and off a number of times over a set time period."
::= { lgpFlexConditionsWellKnown 4684 }
lgpCondId4687Compressor2AShortCycle OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor 2A short cycle. A short cycle is defined as turning on
and off a number of times over a set time period."
::= { lgpFlexConditionsWellKnown 4687 }
lgpCondId4690Compressor2BShortCycle OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor 2B short cycle. A short cycle is defined as turning on
and off a number of times over a set time period."
::= { lgpFlexConditionsWellKnown 4690 }
lgpCondId4693Tandem1LowSuctionPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"'Tandem compressors' 1 low suction pressure."
::= { lgpFlexConditionsWellKnown 4693 }
lgpCondId4696Tandem2LowSuctionPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"'Tandem compressors' 2 low suction pressure."
::= { lgpFlexConditionsWellKnown 4696 }
lgpCondId4703ChilledWaterControlValvePosition OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Chilled water valve out of position. Chilled water control valve
position does not match expected value."
::= { lgpFlexConditionsWellKnown 4703 }
lgpCondId4711SystemCondensationDetected OBJECT-IDENTITY
STATUS current
DESCRIPTION
"System condensation detected."
::= { lgpFlexConditionsWellKnown 4711 }
lgpCondId4714ShutdownLossOfPower OBJECT-IDENTITY
STATUS current
DESCRIPTION
"System lost power. This event becomes active when the unit is
powered on following an unexpected loss of power."
::= { lgpFlexConditionsWellKnown 4714 }
lgpCondId4720SmokeDetected OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Smoke detected."
::= { lgpFlexConditionsWellKnown 4720 }
lgpCondId4723WaterUnderFloor OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Water under the floor is detected."
::= { lgpFlexConditionsWellKnown 4723 }
lgpCondId4726ServiceRequired OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Unit requires servicing."
::= { lgpFlexConditionsWellKnown 4726 }
lgpCondId4729FanIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more fans are not operating within their operational
parameters."
::= { lgpFlexConditionsWellKnown 4729 }
lgpCondId4732ReceptacleLoadDropped OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The receptacle's load is not drawing power."
::= { lgpFlexConditionsWellKnown 4732 }
lgpCondId4740BatteryAutomaticTestInhibited OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Automatic (scheduled) battery tests are inhibited."
::= { lgpFlexConditionsWellKnown 4740 }
lgpCondId4741BatterySelfTest OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery self test is in progress."
::= { lgpFlexConditionsWellKnown 4741 }
lgpCondId4742BatteryLowShutdown OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery disconnect due to end-of-discharge."
::= { lgpFlexConditionsWellKnown 4742 }
lgpCondId4747EquipmentTemperatureSensorFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more temperature sensors report a temperature outside of
the range of expected operation."
::= { lgpFlexConditionsWellKnown 4747 }
lgpCondId4749SystemFanFailureRedundant OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Redundant system fan failure."
::= { lgpFlexConditionsWellKnown 4749 }
lgpCondId4750MultipleFanFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Multiple fan failure."
::= { lgpFlexConditionsWellKnown 4750 }
lgpCondId4753MainControllerFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A Main Controller fault has been detected."
::= { lgpFlexConditionsWellKnown 4753 }
lgpCondId4754SystemBreakersCloseFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more breakers in the system failed to close."
::= { lgpFlexConditionsWellKnown 4754 }
lgpCondId4755InputFilterCycleLock OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The input filter disconnect is open due to exceeding the maximum
number of cycles."
::= { lgpFlexConditionsWellKnown 4755 }
lgpCondId4756ServiceCodeActive OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Service code is running."
::= { lgpFlexConditionsWellKnown 4756 }
lgpCondId4757LBSActive OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Load Bus Sync option is active."
::= { lgpFlexConditionsWellKnown 4757 }
lgpCondId4758LBSInhibited OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected that conditions to perform Load Bus Sync
are not satisfied."
::= { lgpFlexConditionsWellKnown 4758 }
lgpCondId4759LeadingPowerFactor OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The leading output Power Factor has fallen below a specified value."
::= { lgpFlexConditionsWellKnown 4759 }
lgpCondId4760ControlsResetRequired OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A controls reset is required due to one or more critical settings
changing."
::= { lgpFlexConditionsWellKnown 4760 }
lgpCondId4823ParallelCommWarning OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Parallel communication bus warning."
::= { lgpFlexConditionsWellKnown 4823 }
lgpCondId4824SystemCommFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Failure of a device on the multi-module system communication bus."
::= { lgpFlexConditionsWellKnown 4824 }
lgpCondId4825LossofRedundancy OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The multi-module collection doesn't have enough modules to satisfy
the redundancy configuration."
::= { lgpFlexConditionsWellKnown 4825 }
lgpCondId4826BPSSStartupInhibit OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Bypass Static Switch startup is inhibited."
::= { lgpFlexConditionsWellKnown 4826 }
lgpCondId4827MMSTransferInhibit OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The critical load can not be manually transferred from inverter to
bypass."
::= { lgpFlexConditionsWellKnown 4827 }
lgpCondId4828MMSRetransferInhibit OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The critical load can not be manually retransferred from bypass to
inverter."
::= { lgpFlexConditionsWellKnown 4828 }
lgpCondId4830MMSLossofSyncPulse OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Multi-module system loss of sync pulse."
::= { lgpFlexConditionsWellKnown 4830 }
lgpCondId4831MMSOverload OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Multi-module system overload."
::= { lgpFlexConditionsWellKnown 4831 }
lgpCondId4834MMSOnBattery OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The multi-module system is on battery."
::= { lgpFlexConditionsWellKnown 4834 }
lgpCondId4835MMSLowBatteryWarning OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Multi-module system low battery warning."
::= { lgpFlexConditionsWellKnown 4835 }
lgpCondId4906LowAmbientTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a low ambient temperature condition."
::= { lgpFlexConditionsWellKnown 4906 }
lgpCondId4907HighAmbientTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a high ambient temperature condition."
::= { lgpFlexConditionsWellKnown 4907 }
lgpCondId4908LowOverallVoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a low battery string overall voltage
condition."
::= { lgpFlexConditionsWellKnown 4908 }
lgpCondId4909HighOverallVoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a high battery string overall voltage
condition."
::= { lgpFlexConditionsWellKnown 4909 }
lgpCondId4910HighBatteryStringCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a high battery string current condition."
::= { lgpFlexConditionsWellKnown 4910 }
lgpCondId4911LowBatteryStringFloatCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a low battery string float current
condition."
::= { lgpFlexConditionsWellKnown 4911 }
lgpCondId4912HighBatteryStringFloatCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a high battery string float current
condition."
::= { lgpFlexConditionsWellKnown 4912 }
lgpCondId4913HighBatteryStringRippleCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a high battery string ripple current
condition."
::= { lgpFlexConditionsWellKnown 4913 }
lgpCondId4914BatteryStringDischargeDetected OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a battery string discharge condition."
::= { lgpFlexConditionsWellKnown 4914 }
lgpCondId4915MaximumDischargeTimeExceeded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected an excessive discharge time condition."
::= { lgpFlexConditionsWellKnown 4915 }
lgpCondId4916DischargeLowOverallVoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a low battery string overall voltage
condition during a discharge."
::= { lgpFlexConditionsWellKnown 4916 }
lgpCondId4917DischargeLowCellVoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a low cell voltage condition during a
discharge."
::= { lgpFlexConditionsWellKnown 4917 }
lgpCondId4918DischargeHighBatteryStringCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a high battery string current condition
during a discharge."
::= { lgpFlexConditionsWellKnown 4918 }
lgpCondId4919ExcessiveCelltoCellTemperatureDeviation OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected an excessive cell to cell temperature
deviation condition."
::= { lgpFlexConditionsWellKnown 4919 }
lgpCondId4920ExcessiveCelltoAmbientTemperatureDeviation OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected an excessive cell to ambient temperature
deviation condition."
::= { lgpFlexConditionsWellKnown 4920 }
lgpCondId4964LowCellVoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a low cell voltage condition."
::= { lgpFlexConditionsWellKnown 4964 }
lgpCondId4965HighCellVoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a high cell voltage condition."
::= { lgpFlexConditionsWellKnown 4965 }
lgpCondId4966LowCellTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a low cell temperature condition."
::= { lgpFlexConditionsWellKnown 4966 }
lgpCondId4967HighCellTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a high cell temperature condition."
::= { lgpFlexConditionsWellKnown 4967 }
lgpCondId4968LowInternalResistance OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a low internal resistance condition."
::= { lgpFlexConditionsWellKnown 4968 }
lgpCondId4969HighInternalResistance OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a high internal resistance condition."
::= { lgpFlexConditionsWellKnown 4969 }
lgpCondId4970HighIntercellResistance OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a high intercell resistance condition."
::= { lgpFlexConditionsWellKnown 4970 }
lgpCondId4978IntertierResistanceHigh OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a high intertier resistance condition."
::= { lgpFlexConditionsWellKnown 4978 }
lgpCondId4980SupplyChilledWaterLossofFlow OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Supply chilled water or glycol flow is too low."
::= { lgpFlexConditionsWellKnown 4980 }
lgpCondId4983SupplyRefrigOverTempBand1 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Supply Refrigerant Temperature] is above the upper threshold
specified by [Supply Refrig Temp Band 1]."
::= { lgpFlexConditionsWellKnown 4983 }
lgpCondId4986SupplyRefrigUnderTempBand1 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Supply Refrigerant Temperature] is below the lower threshold
specified by [Supply Refrig Temp Band 1]."
::= { lgpFlexConditionsWellKnown 4986 }
lgpCondId4990SupplyRefrigOverTempBand2 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Supply Refrigerant Temperature] is above the upper threshold
specified by [Supply Refrig Temp Band 2]."
::= { lgpFlexConditionsWellKnown 4990 }
lgpCondId4993SupplyRefrigUnderTempBand2 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Supply Refrigerant Temperature] is below the lower threshold
specified by [Supply Refrig Temp Band 2]."
::= { lgpFlexConditionsWellKnown 4993 }
lgpCondId4996Inverter1ShortCycle OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Inverter for pump 1 has short cycled and is temporarily locked out
from further operation to protect from thermal overload. A short
cycle is defined as powering on and off a number of times over a
set time period."
::= { lgpFlexConditionsWellKnown 4996 }
lgpCondId4999Inverter2ShortCycle OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Inverter for pump 2 has short cycled and is temporarily locked out
from further operation to protect from thermal overload. A short
cycle is defined as powering on and off a number of times over a
set time period."
::= { lgpFlexConditionsWellKnown 4999 }
lgpCondId5015SupplyAirOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Supply Air Temperature] has exceeded [High Supply Air Temperature
Threshold]."
::= { lgpFlexConditionsWellKnown 5015 }
lgpCondId5019SupplyAirUnderTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Supply Air Temperature] has dropped below [Low Supply Air
Temperature Threshold]."
::= { lgpFlexConditionsWellKnown 5019 }
lgpCondId5023ReturnAirOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Return Air Temperature] has exceeded [High Return Air Temperature
Threshold]."
::= { lgpFlexConditionsWellKnown 5023 }
lgpCondId5026SupplyAirSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The air sensor at the outlet of the unit is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 5026 }
lgpCondId5034HighReturnHumidity OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Return Humidity] has exceeded [High Return Humidity Threshold]."
::= { lgpFlexConditionsWellKnown 5034 }
lgpCondId5036LowReturnHumidity OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Return Humidity] has dropped below [Low Return Humidity
Threshold]."
::= { lgpFlexConditionsWellKnown 5036 }
lgpCondId5037HumidifierHoursExceeded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Operating hours for the humidifier have exceeded the threshold."
::= { lgpFlexConditionsWellKnown 5037 }
lgpCondId5038DehumidifierHoursExceeded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Operating hours for the dehumidifier have exceeded the threshold."
::= { lgpFlexConditionsWellKnown 5038 }
lgpCondId5039HumidifierUnderCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The electrical current to the humidifier has dropped below its
lower threshold."
::= { lgpFlexConditionsWellKnown 5039 }
lgpCondId5040HumidifierOverCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The electrical current to the humidifier has exceeded its upper
threshold."
::= { lgpFlexConditionsWellKnown 5040 }
lgpCondId5041HumidifierLowWater OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The water level in the humidifier has dropped below its threshold."
::= { lgpFlexConditionsWellKnown 5041 }
lgpCondId5042HumidifierCylinderWorn OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Humidifier cylinder is not operating properly and needs to be
replaced."
::= { lgpFlexConditionsWellKnown 5042 }
lgpCondId5043HumidifierIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Humidifier issue detected, causing it to be locked out."
::= { lgpFlexConditionsWellKnown 5043 }
lgpCondId5044ExtHumidifierLockout OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The humidifier is shut down and disabled by an external input
signal."
::= { lgpFlexConditionsWellKnown 5044 }
lgpCondId5045HumidifierControlBoardNotDetected OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Humidifier control board is required to be connected, but no
signal is detected."
::= { lgpFlexConditionsWellKnown 5045 }
lgpCondId5046ReturnHumidityOutOfProportionalBand OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Return Humidity] has exceeded the upper limit of
[Dehumidification Proportional Band], or has dropped below the
lower limit of [Humidification Proportional Band] ], for an
extended period of time."
::= { lgpFlexConditionsWellKnown 5046 }
lgpCondId5053LossofAirFlow OBJECT-IDENTITY
STATUS current
DESCRIPTION
"No air flow through the unit due to failure of all fans."
::= { lgpFlexConditionsWellKnown 5053 }
lgpCondId5054FanHoursExceeded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Operating hours for the unit blower fan have exceeded the
threshold."
::= { lgpFlexConditionsWellKnown 5054 }
lgpCondId5055TopFanIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The top fan is not operating within its normal parameters."
::= { lgpFlexConditionsWellKnown 5055 }
lgpCondId5056BottomFanIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The bottom fan is not operating within its normal parameters."
::= { lgpFlexConditionsWellKnown 5056 }
lgpCondId5060RemoteSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Remote sensor is disconnected or the signal is out of range."
::= { lgpFlexConditionsWellKnown 5060 }
lgpCondId5062Compressor1LowSuctionPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor 1 low suction pressure."
::= { lgpFlexConditionsWellKnown 5062 }
lgpCondId5063Compressor1HoursExceeded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Operating hours for compressor 1 have exceeded the threshold."
::= { lgpFlexConditionsWellKnown 5063 }
lgpCondId5064DigScrollComp1TempSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Digital scroll compressor 1 temperature sensor is disconnected or
the signal is out of range."
::= { lgpFlexConditionsWellKnown 5064 }
lgpCondId5065DigScrollComp1OverTemp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Digital scroll compressor 1 shut off because its head temperature
has exceeded the upper threshold."
::= { lgpFlexConditionsWellKnown 5065 }
lgpCondId5066Compressor1LowPressureTransducerIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor 1 low pressure transducer is disconnected or the signal
is out of range."
::= { lgpFlexConditionsWellKnown 5066 }
lgpCondId5067ExtCompressorLockout OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The compressor is shut down and disabled by an external input
signal."
::= { lgpFlexConditionsWellKnown 5067 }
lgpCondId5068ReheaterOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The temperature of the reheater has exceeded its threshold."
::= { lgpFlexConditionsWellKnown 5068 }
lgpCondId5069ElectricReheater1HoursExceeded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Operating hours for electric reheater 1 have exceeded the
threshold."
::= { lgpFlexConditionsWellKnown 5069 }
lgpCondId5070ExtReheatLockout OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The reheater is shut down and disabled by an external input signal."
::= { lgpFlexConditionsWellKnown 5070 }
lgpCondId5071Condenser1Issue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Condenser 1 is not operating within its normal parameters."
::= { lgpFlexConditionsWellKnown 5071 }
lgpCondId5072CondenserVFDIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The condenser fan Variable Frequency Drive is offline."
::= { lgpFlexConditionsWellKnown 5072 }
lgpCondId5073CondenserTVSSIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The condenser Transient Voltage Surge Suppressor or Surge
Protection Device has failed."
::= { lgpFlexConditionsWellKnown 5073 }
lgpCondId5104ExtOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A temperature has exceeded its threshold, as indicated by an
external input signal."
::= { lgpFlexConditionsWellKnown 5104 }
lgpCondId5105ExtLossofFlow OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Loss of flow is detected, as indicated by an external input signal."
::= { lgpFlexConditionsWellKnown 5105 }
lgpCondId5106ExtCondenserPumpHighWater OBJECT-IDENTITY
STATUS current
DESCRIPTION
"High water is detected in the condensate pump by the auxiliary
float, as indicated by an external input signal."
::= { lgpFlexConditionsWellKnown 5106 }
lgpCondId5107ExtStandbyGlycolPumpOn OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The standby glycol pump is on, as indicated by an external input
signal."
::= { lgpFlexConditionsWellKnown 5107 }
lgpCondId5108ExternalFireDetected OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Fire detected, as indicated by an external input signal."
::= { lgpFlexConditionsWellKnown 5108 }
lgpCondId5109UnitOn OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Unit was turned on."
::= { lgpFlexConditionsWellKnown 5109 }
lgpCondId5110UnitOff OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Unit was turned off."
::= { lgpFlexConditionsWellKnown 5110 }
lgpCondId5111UnitStandby OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Unit was placed in standby mode."
::= { lgpFlexConditionsWellKnown 5111 }
lgpCondId5112UnitPartialShutdown OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An event has occurred requiring some system components to be
shutdown and disabled."
::= { lgpFlexConditionsWellKnown 5112 }
lgpCondId5113UnitShutdown OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An event has occurred requiring the unit to be shutdown and
disabled to prevent damage to the system."
::= { lgpFlexConditionsWellKnown 5113 }
lgpCondId5114WaterLeakageDetectorSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The water leakage detector sensor is disconnected or the signal is
out of range."
::= { lgpFlexConditionsWellKnown 5114 }
lgpCondId5115BMSCommunicationsTimeout OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Building Management System (or external monitoring system) has not
communicated with the system within the expected timeframe."
::= { lgpFlexConditionsWellKnown 5115 }
lgpCondId5116MaintenanceDue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The calculated maintenance date has been reached."
::= { lgpFlexConditionsWellKnown 5116 }
lgpCondId5117MaintenanceCompleted OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Maintenance has been completed on the unit."
::= { lgpFlexConditionsWellKnown 5117 }
lgpCondId5118CloggedAirFilter OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Air filter is dirty and needs to be (cleaned or) replaced."
::= { lgpFlexConditionsWellKnown 5118 }
lgpCondId5119RAMBatteryIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"RAM or RAM backup battery is not operating correctly."
::= { lgpFlexConditionsWellKnown 5119 }
lgpCondId5120MasterUnitCommunicationLost OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Communication with master unit has been lost."
::= { lgpFlexConditionsWellKnown 5120 }
lgpCondId5121HighPowerShutdown OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Supply to high power components has been shutdown."
::= { lgpFlexConditionsWellKnown 5121 }
lgpCondId5126DigScrollComp2OverTemp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Digital scroll compressor 2 shut off because its head temperature
has exceeded the upper threshold."
::= { lgpFlexConditionsWellKnown 5126 }
lgpCondId5144OutputOfUf OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The output frequency has exceeded a specified range for a
specified period of time."
::= { lgpFlexConditionsWellKnown 5144 }
lgpCondId5145MMSModuleAlarmActive OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Active alarm or fault of any module in a multi-module system."
::= { lgpFlexConditionsWellKnown 5145 }
lgpCondId5146CompressorPumpDownIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Unable to pump down suction-side pressure during compressor
shutdown."
::= { lgpFlexConditionsWellKnown 5146 }
lgpCondId5147ReturnAirSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The air sensor at the inlet of the unit is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 5147 }
lgpCondId5148CompressorHighPressureTransducerIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor high pressure transducer is disconnected or the signal
is out of range."
::= { lgpFlexConditionsWellKnown 5148 }
lgpCondId5149BatteryNotQualified OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The UPS battery voltage is not qualified. This event will be
detected even in the absence of battery disconnect or when it is
open."
::= { lgpFlexConditionsWellKnown 5149 }
lgpCondId5150BatteryTerminalsReversed OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The measured battery voltage is a negative value due to reverse
battery terminal connections."
::= { lgpFlexConditionsWellKnown 5150 }
lgpCondId5151BatteryConverterFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery converter failure. This is a summary event caused by one
or more power sub-modules in a UPS module."
::= { lgpFlexConditionsWellKnown 5151 }
lgpCondId5152InverterSCROpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected an open across one or more inverter static
switch Silicon Controlled Rectifiers."
::= { lgpFlexConditionsWellKnown 5152 }
lgpCondId5153LoadSharingFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Difference between any phase inverter current of unit and the
relevant average output current of parallel system is more than a
specific percent of nominal current."
::= { lgpFlexConditionsWellKnown 5153 }
lgpCondId5154DCBusAbnormal OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected an abnormal DC Bus Voltage."
::= { lgpFlexConditionsWellKnown 5154 }
lgpCondId5155MainsInputNeutralLost OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Loss of neutral in the input source is detected."
::= { lgpFlexConditionsWellKnown 5155 }
lgpCondId5156LoadImpactTransfer OBJECT-IDENTITY
STATUS current
DESCRIPTION
"On bypass as result of load impact."
::= { lgpFlexConditionsWellKnown 5156 }
lgpCondId5157UserOperationInvalid OBJECT-IDENTITY
STATUS current
DESCRIPTION
"User attempted an invalid operation."
::= { lgpFlexConditionsWellKnown 5157 }
lgpCondId5158PowerSubModuleFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more failures detected in power module, inverter or
rectifier."
::= { lgpFlexConditionsWellKnown 5158 }
lgpCondId5178OutputOvervoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more of the output phase voltages has exceeded the limit."
::= { lgpFlexConditionsWellKnown 5178 }
lgpCondId5179OutputUndervoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more of the output phase voltages has dropped below the
limit."
::= { lgpFlexConditionsWellKnown 5179 }
lgpCondId5180OutputOvercurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more of the phase currents has exceeded the limit."
::= { lgpFlexConditionsWellKnown 5180 }
lgpCondId5181NeutralOvercurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system's neutral current has exceeded the limit."
::= { lgpFlexConditionsWellKnown 5181 }
lgpCondId5182GroundOvercurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"System ground current has exceeded the limit."
::= { lgpFlexConditionsWellKnown 5182 }
lgpCondId5183OutputVoltageTHD OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Total Harmonic Distortion of the voltage on one or more of the
output phases has exceeded the limit."
::= { lgpFlexConditionsWellKnown 5183 }
lgpCondId5184OutputFrequencyError OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The output frequency is outside a specified range."
::= { lgpFlexConditionsWellKnown 5184 }
lgpCondId5185TransformerOvertemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Indicates a unit transformer overtemperature condition."
::= { lgpFlexConditionsWellKnown 5185 }
lgpCondId5212PanelSummaryStatus OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The status for the panel. Detects and annunciates upon occurrence
of any branch or panelboard main breaker active event."
::= { lgpFlexConditionsWellKnown 5212 }
lgpCondId5213PanelOvervoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more of the phase voltages of this panel has exceeded the
limit."
::= { lgpFlexConditionsWellKnown 5213 }
lgpCondId5214PanelUndervoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more of the phase voltages of this panel is less than the
limit."
::= { lgpFlexConditionsWellKnown 5214 }
lgpCondId5215PanelOvercurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more of the phase currents of this panel has exceeded the
limit."
::= { lgpFlexConditionsWellKnown 5215 }
lgpCondId5216PanelNeutralOvercurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Neutral current of this panel has exceeded the limit."
::= { lgpFlexConditionsWellKnown 5216 }
lgpCondId5217PanelGroundOvercurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Ground current of this panel has exceeded the limit."
::= { lgpFlexConditionsWellKnown 5217 }
lgpCondId5226BranchOvercurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The current in one or more phases of this branch exceeds the limit."
::= { lgpFlexConditionsWellKnown 5226 }
lgpCondId5227BranchUndercurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The current in one or more phases of this branch is less than the
limit."
::= { lgpFlexConditionsWellKnown 5227 }
lgpCondId5245SubfeedPhaseOvercurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more of the phase currents in this subfeed has exceeded the
limit."
::= { lgpFlexConditionsWellKnown 5245 }
lgpCondId5246SubfeedNeutralOvercurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Neutral current in this subfeed has exceeded the limit."
::= { lgpFlexConditionsWellKnown 5246 }
lgpCondId5247SubfeedGroundOvercurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Ground current of this subfeed has exceeded the limit."
::= { lgpFlexConditionsWellKnown 5247 }
lgpCondId5249EventState OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The present state of this digital event input."
::= { lgpFlexConditionsWellKnown 5249 }
lgpCondId5263CompressorNotStopping OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor commanded to stop, but continues to run."
::= { lgpFlexConditionsWellKnown 5263 }
lgpCondId5269CompressorHoursExceeded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Compressor Hours] has exceeded [Compressor Hours Threshold]."
::= { lgpFlexConditionsWellKnown 5269 }
lgpCondId5270CompressorHighHeadPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor is shut down due to high head pressure."
::= { lgpFlexConditionsWellKnown 5270 }
lgpCondId5271CompressorLowSuctionPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor is shut down due to low suction pressure."
::= { lgpFlexConditionsWellKnown 5271 }
lgpCondId5272CompressorThermalOverload OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor is shut down due to thermal overload."
::= { lgpFlexConditionsWellKnown 5272 }
lgpCondId5273CompressorLowOilPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor low oil pressure."
::= { lgpFlexConditionsWellKnown 5273 }
lgpCondId5274CompressorHeadPressureOverThreshold OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor head pressure has exceeded an upper threshold."
::= { lgpFlexConditionsWellKnown 5274 }
lgpCondId5275CompressorLossofDifferentialPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor is shut down due to low differential pressure."
::= { lgpFlexConditionsWellKnown 5275 }
lgpCondId5277CondenserFanIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Condenser fan is not operating within its operational parameters."
::= { lgpFlexConditionsWellKnown 5277 }
lgpCondId5278LowCondenserRefrigerantPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Refrigerant pressure in condenser coil is too low."
::= { lgpFlexConditionsWellKnown 5278 }
lgpCondId5280LowFluidPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Fluid Pressure] has dropped below a specified threshold."
::= { lgpFlexConditionsWellKnown 5280 }
lgpCondId5293ReturnFluidOverTemp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Return Fluid Temperature] has exceeded a specified threshold."
::= { lgpFlexConditionsWellKnown 5293 }
lgpCondId5294ReturnFluidUnderTemp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Return Fluid Temperature] has dropped below a specified threshold."
::= { lgpFlexConditionsWellKnown 5294 }
lgpCondId5295ReturnFluidTempSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The return fluid temperature sensor is disconnected or the signal
is out of range."
::= { lgpFlexConditionsWellKnown 5295 }
lgpCondId5296TeamworkReturnFluidTempSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The return fluid temperature sensors for all Teamwork units are
disconnected or the signals are out of range."
::= { lgpFlexConditionsWellKnown 5296 }
lgpCondId5297AllPumpsLossofFlow OBJECT-IDENTITY
STATUS current
DESCRIPTION
"System is shut down due to loss of flow in all available pumps."
::= { lgpFlexConditionsWellKnown 5297 }
lgpCondId5300PumpHoursExceeded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Pump Hours] has exceeded [Pump Hours Threshold]."
::= { lgpFlexConditionsWellKnown 5300 }
lgpCondId5306FreeCoolingValveHoursExceeded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Free Cooling Valve Hours] has exceeded [Free Cooling Valve Hours
Threshold]."
::= { lgpFlexConditionsWellKnown 5306 }
lgpCondId5308EvaporatorInletTempSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The evaporator inlet temperature sensor is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 5308 }
lgpCondId5309TeamworkEvaporatorInletTempSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The evaporator inlet temperature sensors for all Teamwork units
are disconnected or the signals are out of range."
::= { lgpFlexConditionsWellKnown 5309 }
lgpCondId5310EvaporatorFluidFreezeAutoReset OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Evaporator outlet fluid temperature has dropped below the freeze
threshold. Evaporator has been shut down, but will restart when
the temperature rises above the threshold."
::= { lgpFlexConditionsWellKnown 5310 }
lgpCondId5311EvaporatorFluidFreezeManualResetRequired OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Evaporator outlet fluid temperature has dropped below the freeze
threshold. Evaporator has been shut down and requires a manual
reset."
::= { lgpFlexConditionsWellKnown 5311 }
lgpCondId5315SubgroupEventOccurredDuringCommunicationLoss OBJECT-IDENTITY
STATUS current
DESCRIPTION
"While subgroup unit communication was lost, an event occurred on
the subgroup unit. Please check subgroup unit event log."
::= { lgpFlexConditionsWellKnown 5315 }
lgpCondId5335ReturnAirUnderTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Return Air Temperature] has dropped below [Low Return Air
Temperature Threshold]."
::= { lgpFlexConditionsWellKnown 5335 }
lgpCondId5349ExtAirSensorAHighHumidity OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Ext Air Sensor A Humidity] has exceeded [Ext Air Sensor A High
Humidity Threshold]."
::= { lgpFlexConditionsWellKnown 5349 }
lgpCondId5351ExtAirSensorALowHumidity OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Ext Air Sensor A Humidity] has dropped below [Ext Air Sensor A
Low Humidity Threshold]."
::= { lgpFlexConditionsWellKnown 5351 }
lgpCondId5352CompressorShortCycle OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor short cycle. A short cycle is defined as turning on and
off a number of times over a set time period."
::= { lgpFlexConditionsWellKnown 5352 }
lgpCondId5354DigScrollCompDischargeTempSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Digital scroll compressor discharge temperature sensor is
disconnected or the signal is out of range."
::= { lgpFlexConditionsWellKnown 5354 }
lgpCondId5355DigScrollCompOverTemp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Digital scroll compressor is shut down due to head temperature
exceeding an upper threshold."
::= { lgpFlexConditionsWellKnown 5355 }
lgpCondId5361ExtFreeCoolingLockout OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Free cooling is disabled by an external input signal."
::= { lgpFlexConditionsWellKnown 5361 }
lgpCondId5362FreeCoolingTempSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The free cooling fluid temperature sensor is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 5362 }
lgpCondId5365HotWaterHotGasValveHoursExceeded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Hot Water / Hot Gas Valve Hours] has exceeded [Hot Water / Hot
Gas Valve Hours Threshold]."
::= { lgpFlexConditionsWellKnown 5365 }
lgpCondId5368ElectricReheaterHoursExceeded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Electric Reheater Hours] has exceeded [Electric Reheaters Hours
Threshold]."
::= { lgpFlexConditionsWellKnown 5368 }
lgpCondId5376MainFanOverload OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Main fan is shut down due to thermal overload."
::= { lgpFlexConditionsWellKnown 5376 }
lgpCondId5377Condenser OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Condenser is not operating within its operational parameters."
::= { lgpFlexConditionsWellKnown 5377 }
lgpCondId5415ExtLossofAirBlower OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Loss of air blower is detected, as indicated by an external input
signal."
::= { lgpFlexConditionsWellKnown 5415 }
lgpCondId5416ExtStandbyUnitOn OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Standby unit is on, as indicated by an external input signal."
::= { lgpFlexConditionsWellKnown 5416 }
lgpCondId5417DigitalOutputBoardNotDetected OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Digital output board is required to be connected, but no signal is
detected."
::= { lgpFlexConditionsWellKnown 5417 }
lgpCondId5418UnitCodeMissing OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Unit code has not been entered and saved."
::= { lgpFlexConditionsWellKnown 5418 }
lgpCondId5419UnitCommunicationLost OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Master has lost communication with one or more networked units."
::= { lgpFlexConditionsWellKnown 5419 }
lgpCondId5422OvertemperaturePowerOff OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Power turned off because equipment over temperature limit."
::= { lgpFlexConditionsWellKnown 5422 }
lgpCondId5423TooManySensors OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The number of sensors connected to the PDU exceeds the allowable
limit."
::= { lgpFlexConditionsWellKnown 5423 }
lgpCondId5432TransformerOvertemperaturePowerOff OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Output power shutdown due to high transformer temperature."
::= { lgpFlexConditionsWellKnown 5432 }
lgpCondId5433TransformerOvertemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Transformer temperature has exceeded the limit."
::= { lgpFlexConditionsWellKnown 5433 }
lgpCondId5434TransformerTemperatureSensorFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Transformer temperature sensor has failed."
::= { lgpFlexConditionsWellKnown 5434 }
lgpCondId5436LowAmbientTemperatureProbeTwo OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a low ambient temperature condition on
temperature probe 2."
::= { lgpFlexConditionsWellKnown 5436 }
lgpCondId5437HighAmbientTemperatureProbeTwo OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a high ambient temperature condition on
temperature probe 2."
::= { lgpFlexConditionsWellKnown 5437 }
lgpCondId5438ThermalRunawayDetected OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a thermal runaway condition."
::= { lgpFlexConditionsWellKnown 5438 }
lgpCondId5439BatteryStringEqualize OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a battery string equalize condition."
::= { lgpFlexConditionsWellKnown 5439 }
lgpCondId5440BatteryStringOffline OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected the battery string is offline."
::= { lgpFlexConditionsWellKnown 5440 }
lgpCondId5442DischargeLowCellVoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a low cell voltage condition during a
discharge."
::= { lgpFlexConditionsWellKnown 5442 }
lgpCondId5447MMSPowerSharing OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A module is not sharing power with the other modules in a multi
-module system."
::= { lgpFlexConditionsWellKnown 5447 }
lgpCondId5453ModuleInStandbyIntelligentParalleling OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Module is placed into standby operation per Intelligent
Paralleling."
::= { lgpFlexConditionsWellKnown 5453 }
lgpCondId5456ECOModeActive OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Conditions for Activation or Automatic Reactivation have been
satisfied."
::= { lgpFlexConditionsWellKnown 5456 }
lgpCondId5457ECOModeSuspended OBJECT-IDENTITY
STATUS current
DESCRIPTION
"ECO Mode session is suspended."
::= { lgpFlexConditionsWellKnown 5457 }
lgpCondId5458ExcessECOSuspends OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Number of automatic suspensions has exceeded the ECO Mode -
Maximum Auto Suspensions setting."
::= { lgpFlexConditionsWellKnown 5458 }
lgpCondId5471DoorOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An open door was detected."
::= { lgpFlexConditionsWellKnown 5471 }
lgpCondId5472DoorSensorDisconnected OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Door sensor disconnect detected."
::= { lgpFlexConditionsWellKnown 5472 }
lgpCondId5479ContactClosureOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An open circuit was detected."
::= { lgpFlexConditionsWellKnown 5479 }
lgpCondId5480ContactClosureClosed OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A closed circuit was detected."
::= { lgpFlexConditionsWellKnown 5480 }
lgpCondId5492ExtSystemCondensationDetected OBJECT-IDENTITY
STATUS current
DESCRIPTION
"External system condensation detected."
::= { lgpFlexConditionsWellKnown 5492 }
lgpCondId5495ExtFanIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more fans are not operating within their operational
parameters."
::= { lgpFlexConditionsWellKnown 5495 }
lgpCondId5500ExtRemoteShutdown OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Unit is shut down by a remote signal."
::= { lgpFlexConditionsWellKnown 5500 }
lgpCondId5505HotAisleTempOutofRange OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The air temperature in the Hot aisle is either above [Hot Aisle
Over Temp Threshold] or below [Hot Aisle Under Temp Threshold]."
::= { lgpFlexConditionsWellKnown 5505 }
lgpCondId5508ColdAisleTempOutofRange OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The air temperature in the cold aisle is either above [Cold Aisle
Over Temp Threshold] or below [Cold Aisle Under Temp Threshold]."
::= { lgpFlexConditionsWellKnown 5508 }
lgpCondId5512RemoteShutdown OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Unit is shut down by a remote signal."
::= { lgpFlexConditionsWellKnown 5512 }
lgpCondId5513CompressorCapacityReduced OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor capacity has been reduced."
::= { lgpFlexConditionsWellKnown 5513 }
lgpCondId5514CompressorLowPressureTransducerIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor low pressure transducer is disconnected or the signal
is out of range."
::= { lgpFlexConditionsWellKnown 5514 }
lgpCondId5524PDUNeutralOverCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a neutral over current condition."
::= { lgpFlexConditionsWellKnown 5524 }
lgpCondId5531CondenserCommunicationLost OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Communication with condenser unit has been lost."
::= { lgpFlexConditionsWellKnown 5531 }
lgpCondId5535CondenserOutsideAirTempSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Condenser outside air temperature sensor is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 5535 }
lgpCondId5536CondenserOutsideAirTempOutofOperatingRange OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Condenser Outside Air Temperature] is either above an upper
threshold or below a lower threshold."
::= { lgpFlexConditionsWellKnown 5536 }
lgpCondId5537CondenserControlBoardIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The condenser control board is reporting an issue."
::= { lgpFlexConditionsWellKnown 5537 }
lgpCondId5539CondenserRefrigerantPressureOverThreshold OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Condenser refrigerant pressure has exceeded a threshold."
::= { lgpFlexConditionsWellKnown 5539 }
lgpCondId5540CondenserRefrigerantPressureUnderThreshold OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Condenser refrigerant pressure has dropped below a threshold."
::= { lgpFlexConditionsWellKnown 5540 }
lgpCondId5541CondenserRefrigerantPressureSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Condenser refrigerant pressure sensor is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 5541 }
lgpCondId5542CondenserSupplyRefrigerantOverTemp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Condenser supply refrigerant temperature has exceeded a threshold."
::= { lgpFlexConditionsWellKnown 5542 }
lgpCondId5543CondenserSupplyRefrigerantUnderTemp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Condenser supply refrigerant temperature has dropped below a
specified threshold."
::= { lgpFlexConditionsWellKnown 5543 }
lgpCondId5544CondenserSupplyRefrigerantTempSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Condenser supply refrigerant temperature sensor is disconnected or
the signal is out of range."
::= { lgpFlexConditionsWellKnown 5544 }
lgpCondId5545CondenserMaxFanSpeedOverride OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Fan speed exceeding the maximum set point in order to alleviate a
high temperature or pressure condition."
::= { lgpFlexConditionsWellKnown 5545 }
lgpCondId5559EvaporatorReturnFluidOverTemp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Evaporator Return Fluid Temperature] has exceeded a threshold.
The event is deactivated when the temperature drops below the
threshold."
::= { lgpFlexConditionsWellKnown 5559 }
lgpCondId5560EvaporatorReturnFluidUnderTemp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Evaporator Return Fluid Temperature] has dropped below a
threshold. The event is deactivated when the temperature rises
above the threshold."
::= { lgpFlexConditionsWellKnown 5560 }
lgpCondId5561LBSActiveMaster OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This UPS system has been selected as the functional Master Load
Bus Synchronization (LBS) system."
::= { lgpFlexConditionsWellKnown 5561 }
lgpCondId5562LBSActiveSlave OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This UPS system is synchronized to the output bus of the UPS
system that has been selected as the Master Load Bus
Synchronization (LBS) system."
::= { lgpFlexConditionsWellKnown 5562 }
lgpCondId5563DCBusLowFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The DC Bus voltage has reached a critical low level."
::= { lgpFlexConditionsWellKnown 5563 }
lgpCondId5564FanContactorOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The fan contactor is open."
::= { lgpFlexConditionsWellKnown 5564 }
lgpCondId5565FanContactorOpenFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The fan contactor failed to open."
::= { lgpFlexConditionsWellKnown 5565 }
lgpCondId5566FanContactorCloseFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The fan contactor failed to close."
::= { lgpFlexConditionsWellKnown 5566 }
lgpCondId5567IPInhibit OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The intelligent paralleling operation is inhibited."
::= { lgpFlexConditionsWellKnown 5567 }
lgpCondId5568InputUndervoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more of the input phase voltages has dropped below the
limit."
::= { lgpFlexConditionsWellKnown 5568 }
lgpCondId5569InputOvervoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more of the input phase voltages has exceeded the limit."
::= { lgpFlexConditionsWellKnown 5569 }
lgpCondId5573AmbientAirSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Ambient air sensor is disconnected or the signal is out of range."
::= { lgpFlexConditionsWellKnown 5573 }
lgpCondId5577ExtDewPointUnderTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"At least one dew point temperature reading ([Ext Air Sensor A Dew
Point Temp], [Ext Air Sensor B Dew Point Temp]...) has dropped
below [Ext Dew Point Under Temp Threshold]."
::= { lgpFlexConditionsWellKnown 5577 }
lgpCondId5578DewPointOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Dew point temperature reading has exceeded the upper threshold."
::= { lgpFlexConditionsWellKnown 5578 }
lgpCondId5579DewPointUnderTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Dew point temperature reading has dropped below the lower
threshold."
::= { lgpFlexConditionsWellKnown 5579 }
lgpCondId5588UnspecifiedGeneralEvent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more unspecified events active. See local unit display for
further details."
::= { lgpFlexConditionsWellKnown 5588 }
lgpCondId5593RemoteSensorAverageOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Remote Sensor Average Temperature] has exceeded [Remote Sensor
Over Temp Threshold]."
::= { lgpFlexConditionsWellKnown 5593 }
lgpCondId5594RemoteSensorAverageUnderTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Remote Sensor Average Temperature] has dropped below [Remote
Sensor Under Temp Threshold]."
::= { lgpFlexConditionsWellKnown 5594 }
lgpCondId5595RemoteSensorSystemAverageOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Remote Sensor System Average Temperature] has exceeded [Remote
Sensor Over Temp Threshold]."
::= { lgpFlexConditionsWellKnown 5595 }
lgpCondId5596RemoteSensorSystemAverageUnderTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Remote Sensor System Average Temperature] has dropped below
[Remote Sensor Under Temp Threshold]."
::= { lgpFlexConditionsWellKnown 5596 }
lgpCondId5597RemoteSensorOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Remote Sensor Temperature] has exceeded [Remote Sensor Over Temp
Threshold]."
::= { lgpFlexConditionsWellKnown 5597 }
lgpCondId5598RemoteSensorUnderTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Remote Sensor Temperature] has dropped below [Remote Sensor Under
Temp Threshold]."
::= { lgpFlexConditionsWellKnown 5598 }
lgpCondId5600AirEconomizerEmergencyOverride OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Indoor room temperature has exceeded its upper threshold and the
outdoor air damper has been opened for emergency cooling."
::= { lgpFlexConditionsWellKnown 5600 }
lgpCondId5601AirEconomizerReducedAirflow OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Air economizer filter is dirty and needs to be cleaned or replaced."
::= { lgpFlexConditionsWellKnown 5601 }
lgpCondId5604CompressorSuperheatOverThreshold OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor discharge refrigerant superheat temperature has
exceeded an upper threshold."
::= { lgpFlexConditionsWellKnown 5604 }
lgpCondId5609ThermalRunawayCelltoAmbientTemperatureEvent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The delta temperature between a cell temperature and the ambient
temperature has exceeded the thermal runaway cell to ambient
temperature threshold."
::= { lgpFlexConditionsWellKnown 5609 }
lgpCondId5610ThermalRunawayCelltoCellTemperatureEvent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The delta temperature between two cells has exceeded the thermal
runaway cell to cell temperature threshold."
::= { lgpFlexConditionsWellKnown 5610 }
lgpCondId5611ThermalRunawayChargerCurrentLevelOneEvent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Battery-String charger current has exceeded the thermal
runaway charger current level one threshold."
::= { lgpFlexConditionsWellKnown 5611 }
lgpCondId5612ThermalRunawayChargerCurrentLevelTwoEvent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Battery-String charger current has exceeded the thermal
runaway charger current level two threshold."
::= { lgpFlexConditionsWellKnown 5612 }
lgpCondId5617TemperatureControlSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The air sensor selected for cooling control is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 5617 }
lgpCondId5621EEVSuperheatBelowThreshold OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Electronic expansion valve refrigerant low superheat event."
::= { lgpFlexConditionsWellKnown 5621 }
lgpCondId5622EEVDischargeTempAboveThreshold OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Electronic expansion valve refrigerant high discharge temperature
event."
::= { lgpFlexConditionsWellKnown 5622 }
lgpCondId5623EEVBatteryIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Electronic expansion valve battery cannot be recharged and needs
to be replaced."
::= { lgpFlexConditionsWellKnown 5623 }
lgpCondId5624EEVPowerIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Electronic expansion valve lost power and is running on battery
backup."
::= { lgpFlexConditionsWellKnown 5624 }
lgpCondId5625EEVUnspecifiedGeneralEvent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more unspecified electronic expansion valve events active.
See local unit display for further details."
::= { lgpFlexConditionsWellKnown 5625 }
lgpCondId5629StaticPressureSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The static pressure sensor is disconnected or the signal is out of
range."
::= { lgpFlexConditionsWellKnown 5629 }
lgpCondId5630HighStaticPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"High static pressure event."
::= { lgpFlexConditionsWellKnown 5630 }
lgpCondId5631LowStaticPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Low static pressure event."
::= { lgpFlexConditionsWellKnown 5631 }
lgpCondId5636PumpUnspecifiedGeneralEvent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more unspecified pump events active. See local unit display
for further details."
::= { lgpFlexConditionsWellKnown 5636 }
lgpCondId5637CondenserUnitUnspecifiedGeneralEvent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more unspecified condenser unit events active. See local
unit display for further details."
::= { lgpFlexConditionsWellKnown 5637 }
lgpCondId5638CondenserCircuitUnspecifiedGeneralEvent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more unspecified condenser circuit events active. See local
unit display for further details."
::= { lgpFlexConditionsWellKnown 5638 }
lgpCondId5642SFAReservedEvent1 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5642 }
lgpCondId5643SFAReservedEvent2 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5643 }
lgpCondId5644SFAReservedEvent3 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5644 }
lgpCondId5645SFAReservedEvent4 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5645 }
lgpCondId5646SFAReservedEvent5 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5646 }
lgpCondId5647SFAReservedEvent6 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5647 }
lgpCondId5648SFAReservedEvent7 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5648 }
lgpCondId5649SFAReservedEvent8 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5649 }
lgpCondId5650SFAReservedEvent9 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5650 }
lgpCondId5651SFAReservedEvent10 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5651 }
lgpCondId5652SFAReservedEvent11 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5652 }
lgpCondId5653SFAReservedEvent12 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5653 }
lgpCondId5654SFAReservedEvent13 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5654 }
lgpCondId5655SFAReservedEvent14 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5655 }
lgpCondId5656SFAReservedEvent15 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5656 }
lgpCondId5657SFAReservedEvent16 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5657 }
lgpCondId5658SFAReservedEvent17 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5658 }
lgpCondId5659SFAReservedEvent18 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5659 }
lgpCondId5660SFAReservedEvent19 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5660 }
lgpCondId5661SFAReservedEvent20 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5661 }
lgpCondId5662SFAReservedEvent21 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5662 }
lgpCondId5663SFAReservedEvent22 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5663 }
lgpCondId5664SFAReservedEvent23 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5664 }
lgpCondId5665SFAReservedEvent24 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5665 }
lgpCondId5666SFAReservedEvent25 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 5666 }
lgpCondId5768OutletAirOvertemperatureLimit OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The difference between the outlet air temperature and inlet air
temperature exceeds a specified maximum temperature."
::= { lgpFlexConditionsWellKnown 5768 }
lgpCondId5769EMOShutdown OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An Emergency Module Off command has been detected."
::= { lgpFlexConditionsWellKnown 5769 }
lgpCondId5770TopOutletFanFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Top outlet fan fault - one or more top outlet fans have failed."
::= { lgpFlexConditionsWellKnown 5770 }
lgpCondId5771MMSOverCapacity OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The multi-module system load is larger than the apparent power
limit setting."
::= { lgpFlexConditionsWellKnown 5771 }
lgpCondId5773CompressorCapacityNormal OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor has returned to normal load capacity."
::= { lgpFlexConditionsWellKnown 5773 }
lgpCondId5774CompressorContactorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor contactor is not closing during compressor startup or
is not opening during compressor shutdown."
::= { lgpFlexConditionsWellKnown 5774 }
lgpCondId5775UnitShutdownUnspecifiedGeneralEvent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more unspecified unit shutdown events active. See local
unit display for further details."
::= { lgpFlexConditionsWellKnown 5775 }
lgpCondId5776PDULowVoltageLN OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module under voltage condition (LN)."
::= { lgpFlexConditionsWellKnown 5776 }
lgpCondId5777PDULowVoltageLL OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module under voltage condition (LL)."
::= { lgpFlexConditionsWellKnown 5777 }
lgpCondId5778PDULowVoltageL1L2 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a line-to-line under voltage condition (L1
-L2)."
::= { lgpFlexConditionsWellKnown 5778 }
lgpCondId5779PDULowVoltageL2L3 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a line-to-line under voltage condition (L2
-L3)."
::= { lgpFlexConditionsWellKnown 5779 }
lgpCondId5780PDULowVoltageL3L1 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a line-to-line under voltage condition (L3
-L1)."
::= { lgpFlexConditionsWellKnown 5780 }
lgpCondId5781PDULowVoltageL1N OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a line to neutral under voltage condition
(L1-N)."
::= { lgpFlexConditionsWellKnown 5781 }
lgpCondId5782PDULowVoltageL2N OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a line to neutral under voltage condition
(L2-N)."
::= { lgpFlexConditionsWellKnown 5782 }
lgpCondId5783PDULowVoltageL3N OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a line to neutral under voltage condition
(L3-N)."
::= { lgpFlexConditionsWellKnown 5783 }
lgpCondId5784BranchLowVoltageLN OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module under voltage condition (LN)."
::= { lgpFlexConditionsWellKnown 5784 }
lgpCondId5785BranchLowVoltageLL OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module under voltage condition (LL)."
::= { lgpFlexConditionsWellKnown 5785 }
lgpCondId5786BranchLowVoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module under voltage condition."
::= { lgpFlexConditionsWellKnown 5786 }
lgpCondId5788ContTieActive OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Continuous Power Tie Active."
::= { lgpFlexConditionsWellKnown 5788 }
lgpCondId5792UserkWhReset OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The user kWh accumulator was reset to zero by the operator."
::= { lgpFlexConditionsWellKnown 5792 }
lgpCondId5796PeakkWReset OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Peak kW was reset."
::= { lgpFlexConditionsWellKnown 5796 }
lgpCondId5798BypassOverload OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Bypass overloaded, reduce load immediately."
::= { lgpFlexConditionsWellKnown 5798 }
lgpCondId5801LowBatteryShutdownImminent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"If active and guaranteed shutdown is enabled, a low battery
reserve condition exists that will shutdown the UPS."
::= { lgpFlexConditionsWellKnown 5801 }
lgpCondId5806OutputOverload OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An overload exists on the output."
::= { lgpFlexConditionsWellKnown 5806 }
lgpCondId5807OutputOffPending OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Output off pending - shutdown imminent."
::= { lgpFlexConditionsWellKnown 5807 }
lgpCondId5808SystemShutdownOutputShort OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Shutdown was due to a short on the output."
::= { lgpFlexConditionsWellKnown 5808 }
lgpCondId5809SystemShutdownLowBattery OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Shutdown was due to a low battery condition."
::= { lgpFlexConditionsWellKnown 5809 }
lgpCondId5810SystemShutdownRemoteShutdown OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Shutdown was due to a remote communications shutdown command."
::= { lgpFlexConditionsWellKnown 5810 }
lgpCondId5811SystemShutdownHardwareFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Shutdown was due to an externally applied hardware control signal."
::= { lgpFlexConditionsWellKnown 5811 }
lgpCondId5817LossofRedundancy OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has an insufficient number of power modules to provide
redundancy."
::= { lgpFlexConditionsWellKnown 5817 }
lgpCondId5818PowerModuleFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more conditions indicate a power module failure, service is
required."
::= { lgpFlexConditionsWellKnown 5818 }
lgpCondId5819PowerModuleWarning OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more power modules is reporting a warning condition."
::= { lgpFlexConditionsWellKnown 5819 }
lgpCondId5838PowerModuleFanFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Power Module has detected a fan fault."
::= { lgpFlexConditionsWellKnown 5838 }
lgpCondId5839PowerModuleOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Power Module has detected an over temperature condition."
::= { lgpFlexConditionsWellKnown 5839 }
lgpCondId5840PowerModuleShutdownOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Power Module has shutdown due to over temperature."
::= { lgpFlexConditionsWellKnown 5840 }
lgpCondId5842ChargerModuleFanFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Charger Module has detected a fan fault."
::= { lgpFlexConditionsWellKnown 5842 }
lgpCondId5847BatteryModuleTemperatureSensorFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A Battery Module temperature sensor fault has been detected."
::= { lgpFlexConditionsWellKnown 5847 }
lgpCondId5848BatteryModuleOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Battery Module has detected an over temperature condition."
::= { lgpFlexConditionsWellKnown 5848 }
lgpCondId5849ReplaceBatteryModule OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Battery Module needs to be replaced."
::= { lgpFlexConditionsWellKnown 5849 }
lgpCondId5850SystemShutdownTransformerOverTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"System shutdown due to transformer over temperature."
::= { lgpFlexConditionsWellKnown 5850 }
lgpCondId5851MaximumLoadAlarm OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Maximum load alarm indicating load setting has been exceeded."
::= { lgpFlexConditionsWellKnown 5851 }
lgpCondId5856BatteryModuleFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more battery modules are reporting a fault condition."
::= { lgpFlexConditionsWellKnown 5856 }
lgpCondId5857BatteryModuleWarning OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more battery modules are reporting a warning condition."
::= { lgpFlexConditionsWellKnown 5857 }
lgpCondId5862CheckAirFilter OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Please check air filter, it may need to be cleaned or replaced."
::= { lgpFlexConditionsWellKnown 5862 }
lgpCondId5863TransformerFanFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The transformer fan has failed."
::= { lgpFlexConditionsWellKnown 5863 }
lgpCondId5865NoLoadWarning OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Indicates the UPS has output voltage but the output current is
below a set threshold [No Load Warning Current Threshold] for a
set period of time [No Load Warning Delay]."
::= { lgpFlexConditionsWellKnown 5865 }
lgpCondId5871BatteryOverTemperatureLimit OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A battery temperature sensor is reporting a value above a
predetermined limit."
::= { lgpFlexConditionsWellKnown 5871 }
lgpCondId5873UnexpectedMainBatteryDisconnectClosure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The main battery disconnect has closed unexpectedly."
::= { lgpFlexConditionsWellKnown 5873 }
lgpCondId5874BatteryOverVoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected that the battery voltage has exceeded a
predetermined limit."
::= { lgpFlexConditionsWellKnown 5874 }
lgpCondId5875BatteryFuseFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more battery fuse faults has occurred."
::= { lgpFlexConditionsWellKnown 5875 }
lgpCondId5878MainBatteryDisconnectForcedToUnlock OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The main battery disconnect is forced to the unlocked state."
::= { lgpFlexConditionsWellKnown 5878 }
lgpCondId5879VdcBackfeed OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The voltage between battery and DC bus measurements is out of
tolerance."
::= { lgpFlexConditionsWellKnown 5879 }
lgpCondId5880RectifierConfigurationChangeRequest OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This event indicates that the battery is not configured and PFC is
not enabled."
::= { lgpFlexConditionsWellKnown 5880 }
lgpCondId5881RegenerationActive OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Regeneration operation is active."
::= { lgpFlexConditionsWellKnown 5881 }
lgpCondId5882RegenerationOperationTerminated OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Regeneration operation is not active."
::= { lgpFlexConditionsWellKnown 5882 }
lgpCondId5883RegenerationOperationFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Regeneration operation has been terminated due to bypass source
instability or unit misoperation."
::= { lgpFlexConditionsWellKnown 5883 }
lgpCondId5884ProgramInputContact01 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"When the signal from [Program Input Contact 01] is active the
function assigned to this contact is executed."
::= { lgpFlexConditionsWellKnown 5884 }
lgpCondId5885ProgramInputContact02 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"When the signal from [Program Input Contact 02] is active the
function assigned to this contact is executed."
::= { lgpFlexConditionsWellKnown 5885 }
lgpCondId5886ProgramInputContact03 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"When the signal from [Program Input Contact 03] is active the
function assigned to this contact is executed."
::= { lgpFlexConditionsWellKnown 5886 }
lgpCondId5887ProgramInputContact04 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"When the signal from [Program Input Contact 04] is active the
function assigned to this contact is executed."
::= { lgpFlexConditionsWellKnown 5887 }
lgpCondId5888ProgramInputContact05 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"When the signal from [Program Input Contact 05] is active the
function assigned to this contact is executed."
::= { lgpFlexConditionsWellKnown 5888 }
lgpCondId5889ProgramInputContact06 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"When the signal from [Program Input Contact 06] is active the
function assigned to this contact is executed."
::= { lgpFlexConditionsWellKnown 5889 }
lgpCondId5890ProgramInputContact07 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"When the signal from [Program Input Contact 07] is active the
function assigned to this contact is executed."
::= { lgpFlexConditionsWellKnown 5890 }
lgpCondId5891ProgramInputContact08 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"When the signal from [Program Input Contact 08] is active the
function assigned to this contact is executed."
::= { lgpFlexConditionsWellKnown 5891 }
lgpCondId5892ProgramInputContact09 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"When the signal from [Program Input Contact 09] is active the
function assigned to this contact is executed."
::= { lgpFlexConditionsWellKnown 5892 }
lgpCondId5893ProgramInputContact10 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"When the signal from [Program Input Contact 10] is active the
function assigned to this contact is executed."
::= { lgpFlexConditionsWellKnown 5893 }
lgpCondId5894ProgramInputContact11 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"When the signal from [Program Input Contact 11] is active the
function assigned to this contact is executed."
::= { lgpFlexConditionsWellKnown 5894 }
lgpCondId5895ProgramInputContact12 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"When the signal from [Program Input Contact 12] is active the
function assigned to this contact is executed."
::= { lgpFlexConditionsWellKnown 5895 }
lgpCondId5896GroundFaultDetected OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a ground fault on a Battery-String."
::= { lgpFlexConditionsWellKnown 5896 }
lgpCondId5902ReturnHumiditySensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The humidity sensor at the inlet of the unit is disconnected or
the signal is out of range."
::= { lgpFlexConditionsWellKnown 5902 }
lgpCondId5903CompressorLowDifferentialPressureLockout OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor exceeded maximum startup attempts due to low
differential pressure. Compressor is shutdown and has been
disabled."
::= { lgpFlexConditionsWellKnown 5903 }
lgpCondId5906AirflowSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Airflow sensor is disconnected or the signal is out of range."
::= { lgpFlexConditionsWellKnown 5906 }
lgpCondId5907ExtAirDamperPositionIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Air damper position does not match expected value, as indicated by
an external input signal."
::= { lgpFlexConditionsWellKnown 5907 }
lgpCondId5908ExtPowerSourceAFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Unit main power source A failure, as indicated by an external
input signal."
::= { lgpFlexConditionsWellKnown 5908 }
lgpCondId5909ExtPowerSourceBFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Unit main power source B failure, as indicated by an external
input signal."
::= { lgpFlexConditionsWellKnown 5909 }
lgpCondId5910StaticPressureSensorOutofRange OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Static pressure sensor signal is out of its configured range."
::= { lgpFlexConditionsWellKnown 5910 }
lgpCondId5911FluidTemperatureSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The fluid temperature sensor is disconnected or the signal is out
of range."
::= { lgpFlexConditionsWellKnown 5911 }
lgpCondId5912FluidFlowSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The fluid flow sensor is disconnected or the signal is out of
range."
::= { lgpFlexConditionsWellKnown 5912 }
lgpCondId5914OverDifferentialPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An over differential pressure condition was detected."
::= { lgpFlexConditionsWellKnown 5914 }
lgpCondId5915UnderDifferentialPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An under differential pressure condition was detected."
::= { lgpFlexConditionsWellKnown 5915 }
lgpCondId5924MixedModeLockout OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Mixed mode has been entered too many times over a rolling time
period and has been temporarily disabled. Mixed mode is defined
as the use of a compressor on one refrigeration circuit and the
use of a refrigerant pump on the other circuit."
::= { lgpFlexConditionsWellKnown 5924 }
lgpCondId5928UnbalancedLoadCondition OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a line-to-line unbalanced load condition."
::= { lgpFlexConditionsWellKnown 5928 }
lgpCondId5939BranchOverCurrentProtection OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Branch Receptacle Module's over current protection is
triggered."
::= { lgpFlexConditionsWellKnown 5939 }
lgpCondId5948BranchLowVoltageLL OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a module under voltage condition (LL)."
::= { lgpFlexConditionsWellKnown 5948 }
lgpCondId5957BypassInputVoltageFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected the bypass voltage is unqualified."
::= { lgpFlexConditionsWellKnown 5957 }
lgpCondId5958BatteryTemperatureOutofRange OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery temperature is outside of acceptable range."
::= { lgpFlexConditionsWellKnown 5958 }
lgpCondId5960InverterOverload OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Inverter in overload fault."
::= { lgpFlexConditionsWellKnown 5960 }
lgpCondId5966AuxAirTempDeviceCommunicationLost OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Communication with external auxiliary device providing an air
temperature value has been lost."
::= { lgpFlexConditionsWellKnown 5966 }
lgpCondId5967ModbusPowerMeterCommunicationLost OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Communication with Modbus power meter has been lost."
::= { lgpFlexConditionsWellKnown 5967 }
lgpCondId5968InverterDesaturation OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Inverter Desaturation."
::= { lgpFlexConditionsWellKnown 5968 }
lgpCondId5969GenericDICFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The control board reports a fault - Service required."
::= { lgpFlexConditionsWellKnown 5969 }
lgpCondId5970GroundFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An AC phase to ground fault or three phase fault to ground exists
on the output of the UPS."
::= { lgpFlexConditionsWellKnown 5970 }
lgpCondId5973InputBreakerOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The main input breaker is open."
::= { lgpFlexConditionsWellKnown 5973 }
lgpCondId5974NeutralBreakerOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The neutral breaker is open."
::= { lgpFlexConditionsWellKnown 5974 }
lgpCondId5975OutputBreakerOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The output breaker is open."
::= { lgpFlexConditionsWellKnown 5975 }
lgpCondId5976MaintenanceBypassBreakerClosed OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The maintenance bypass breaker is closed."
::= { lgpFlexConditionsWellKnown 5976 }
lgpCondId5977BatteryBreakerOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The battery circuit is open."
::= { lgpFlexConditionsWellKnown 5977 }
lgpCondId5978RectifierIsolationBreakerRFBOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The rectifier isolation breaker (RFB) indicates that it is in the
open position."
::= { lgpFlexConditionsWellKnown 5978 }
lgpCondId5982BypassBreakerSBBOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The bypass circuit breaker (SBB) indicates that it is in the open
position."
::= { lgpFlexConditionsWellKnown 5982 }
lgpCondId5983BypassIsolationBreakerBIBOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The bypass isolation breaker (BIB) indicates that it is in the
open position."
::= { lgpFlexConditionsWellKnown 5983 }
lgpCondId5984BypassUndervoltageWarning OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The voltage on one or more bypass phases is less than a specified
percentage of the nominal voltage."
::= { lgpFlexConditionsWellKnown 5984 }
lgpCondId5985BypassStaticSwitchBPSSOn OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Bypass Static Switch has been turned on."
::= { lgpFlexConditionsWellKnown 5985 }
lgpCondId5998BattOvtempWarning OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A battery temperature sensor is reporting a value above the
setpoint."
::= { lgpFlexConditionsWellKnown 5998 }
lgpCondId6009InverterOutputBreakerOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The inverter output breaker indicates that it is in the open
position."
::= { lgpFlexConditionsWellKnown 6009 }
lgpCondId6011EquipmentOverTempWarning OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Equipment over temperature warning is a summary event based on the
detection of at least one measured temperature exceeding a
threshold."
::= { lgpFlexConditionsWellKnown 6011 }
lgpCondId6012EquipmentOvertemperatureLimit OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The equipment air temperature has exceeded its maximum set point."
::= { lgpFlexConditionsWellKnown 6012 }
lgpCondId6045RectifierInputBreakerOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The rectifier isolation breaker indicates that it is in the open
position."
::= { lgpFlexConditionsWellKnown 6045 }
lgpCondId6046LoadonUPS OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The output is being supplied power from the inverter."
::= { lgpFlexConditionsWellKnown 6046 }
lgpCondId6047Core2CoreFuseFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Core-2-core fuse failure."
::= { lgpFlexConditionsWellKnown 6047 }
lgpCondId6052SystemOutputBreakerOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system output breaker is open."
::= { lgpFlexConditionsWellKnown 6052 }
lgpCondId6059InverterRelayFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The inverter relay has malfunctioned."
::= { lgpFlexConditionsWellKnown 6059 }
lgpCondId6060TransfertoBypassSystemOverload OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The UPS System has transferred to bypass because the active power
modules cannot support the critical load."
::= { lgpFlexConditionsWellKnown 6060 }
lgpCondId6061InputSourceBackfeed OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The battery is backfeeding the input source."
::= { lgpFlexConditionsWellKnown 6061 }
lgpCondId6062LossofSynchronization OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The inverter and bypass are no longer synchronized. ."
::= { lgpFlexConditionsWellKnown 6062 }
lgpCondId6063BatteryConverterCurrentLimit OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The battery converter has reached is maximum current limit. ."
::= { lgpFlexConditionsWellKnown 6063 }
lgpCondId6064LBSCableFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Load Bus Sync communications is abnormal. A problem with the LBS
cable may exist."
::= { lgpFlexConditionsWellKnown 6064 }
lgpCondId6065BatteryChargeEqualizationTimeout OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The battery equalizing is time out."
::= { lgpFlexConditionsWellKnown 6065 }
lgpCondId6066ParallelCableFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The UPS parallel system communications is abnormal. A problem with
the parallel cable may exist."
::= { lgpFlexConditionsWellKnown 6066 }
lgpCondId6067BatteryFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A short circuit exists in the battery system."
::= { lgpFlexConditionsWellKnown 6067 }
lgpCondId6068BatteryRoomAlarm OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The ambient temperature of the battery room is abnormal."
::= { lgpFlexConditionsWellKnown 6068 }
lgpCondId6080UPSCCommunicationFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The UPSC has failed to communicate in a designated time period."
::= { lgpFlexConditionsWellKnown 6080 }
lgpCondId6092Compressor1BThermalOverload OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Fixed compressor 1B is shut down due to thermal overload."
::= { lgpFlexConditionsWellKnown 6092 }
lgpCondId6093Compressor2BThermalOverload OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Fixed compressor 2B is shut down due to thermal overload."
::= { lgpFlexConditionsWellKnown 6093 }
lgpCondId6094Compressor1BHoursExceeded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Fixed compressor 1B run hours have exceeded the threshold."
::= { lgpFlexConditionsWellKnown 6094 }
lgpCondId6095Compressor2BHoursExceeded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Fixed compressor 2B run hours have exceeded the threshold."
::= { lgpFlexConditionsWellKnown 6095 }
lgpCondId6100CondenserRemoteShutdown OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Condenser is shut down by a remote signal."
::= { lgpFlexConditionsWellKnown 6100 }
lgpCondId6105ExternalCondenserTVSSIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The condenser Transient Voltage Surge Suppressor or Surge
Protection Device has failed, as indicated by an external input
signal."
::= { lgpFlexConditionsWellKnown 6105 }
lgpCondId6106ExternalCondenserVFDIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The condenser fan Variable Frequency Drive is offline, as
indicated by an external input signal."
::= { lgpFlexConditionsWellKnown 6106 }
lgpCondId6107ExternalCondenserIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Condenser is not operating within its operational parameters, as
indicated by an external input signal."
::= { lgpFlexConditionsWellKnown 6107 }
lgpCondId6119Slotsnotavailable OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The number of sensors exceeds the number of allocated slots and
cannot be displayed."
::= { lgpFlexConditionsWellKnown 6119 }
lgpCondId6180BatteryUnderVoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery voltage is too low."
::= { lgpFlexConditionsWellKnown 6180 }
lgpCondId6182ReplaceBattery OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The battery is due for replacement."
::= { lgpFlexConditionsWellKnown 6182 }
lgpCondId6186InputFrequencyDeviation OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The input frequency is outside of the normal range."
::= { lgpFlexConditionsWellKnown 6186 }
lgpCondId6187ShutdownPending OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Shutdown is pending."
::= { lgpFlexConditionsWellKnown 6187 }
lgpCondId6194SystemRebootCommandIssued OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reboot command issued to the system."
::= { lgpFlexConditionsWellKnown 6194 }
lgpCondId6203SensorAdded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sensor Added."
::= { lgpFlexConditionsWellKnown 6203 }
lgpCondId6204SensorRemoved OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sensor Removed."
::= { lgpFlexConditionsWellKnown 6204 }
lgpCondId6205WaterLeakDetected OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Water leak detected."
::= { lgpFlexConditionsWellKnown 6205 }
lgpCondId6210FirmwareUpdateInProgress OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Firmware update has started and is in progress."
::= { lgpFlexConditionsWellKnown 6210 }
lgpCondId6211FirmwareUpdateCompletedSuccessfully OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Firmware update has completed successfully."
::= { lgpFlexConditionsWellKnown 6211 }
lgpCondId6212FirmwareUpdateCompletedUnsuccessfully OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Firmware update has completed, but was not successful."
::= { lgpFlexConditionsWellKnown 6212 }
lgpCondId6216PrechargeCircuitFailed OBJECT-IDENTITY
STATUS current
DESCRIPTION
"DC Bus precharge/discharge didn't reach specified level within a
specified time."
::= { lgpFlexConditionsWellKnown 6216 }
lgpCondId6217MemoryCardRemoved OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The memory card on the control board has been removed."
::= { lgpFlexConditionsWellKnown 6217 }
lgpCondId6218AutoCalibrationActive OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system is automatically calibrating ADC channels."
::= { lgpFlexConditionsWellKnown 6218 }
lgpCondId6219AutoCalibrationFailed OBJECT-IDENTITY
STATUS current
DESCRIPTION
"ADC channel calibration has failed."
::= { lgpFlexConditionsWellKnown 6219 }
lgpCondId6220ModuleOutputBreakerOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The module output breaker is open."
::= { lgpFlexConditionsWellKnown 6220 }
lgpCondId6221NeutralVoltageFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Voltage observed on neutral line."
::= { lgpFlexConditionsWellKnown 6221 }
lgpCondId6222BranchLoadLoss OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Loss of load on branch detected. Branch circuit breaker might be
open."
::= { lgpFlexConditionsWellKnown 6222 }
lgpCondId6225RemoteSensorLowHumidity OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Remote sensor humidity has dropped below a lower threshold. The
event is deactivated when the humidity rises above the threshold."
::= { lgpFlexConditionsWellKnown 6225 }
lgpCondId6226RemoteSensorHighHumidity OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Remote sensor humidity has exceeded an upper threshold. The event
is deactivated when the humidity drops below the threshold."
::= { lgpFlexConditionsWellKnown 6226 }
lgpCondId6227RemoteSensorAverageLowHumidity OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The average humidity of multiple remote sensors on the cooling
unit has dropped below a lower threshold. The event is
deactivated when the humidity rises above the threshold."
::= { lgpFlexConditionsWellKnown 6227 }
lgpCondId6228RemoteSensorAverageHighHumidity OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The average humidity of multiple remote sensors on the cooling
unit has exceeded an upper threshold. The event is deactivated
when the humidity drops below the threshold."
::= { lgpFlexConditionsWellKnown 6228 }
lgpCondId6229RemoteSensorSystemAverageLowHumidity OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The average humidity of multiple remote sensors on interconnected
cooling units in a single system has dropped below a lower
threshold. The event is deactivated when the humidity rises
above the threshold."
::= { lgpFlexConditionsWellKnown 6229 }
lgpCondId6230RemoteSensorSystemAverageHighHumidity OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The average humidity of multiple remote sensors on interconnected
cooling units in a single system has exceeded an upper threshold.
The event is deactivated when the humidity drops below the
threshold."
::= { lgpFlexConditionsWellKnown 6230 }
lgpCondId6231LowCompressorSuperheat OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor suction superheat has dropped below a lower threshold."
::= { lgpFlexConditionsWellKnown 6231 }
lgpCondId6232SECUnspecifiedGeneralEvent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"One or more unspecified events active for the Superheat and
Envelope Controller. See local unit display for further details."
::= { lgpFlexConditionsWellKnown 6232 }
lgpCondId6233SECCommunicationLost OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Communication with the Superheat and Envelope Controller has been
lost. The event is deactivated when communication is re
-established."
::= { lgpFlexConditionsWellKnown 6233 }
lgpCondId6236PowerSourceAIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"No power is detected at power source input 'A'."
::= { lgpFlexConditionsWellKnown 6236 }
lgpCondId6237PowerSourceBIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"No power is detected at power source input 'B'."
::= { lgpFlexConditionsWellKnown 6237 }
lgpCondId6239FluidValveHoursExceeded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Operating hours for the fluid valve have exceeded the threshold."
::= { lgpFlexConditionsWellKnown 6239 }
lgpCondId6253BoosterFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Booster failure - boost is off."
::= { lgpFlexConditionsWellKnown 6253 }
lgpCondId6254ChargerFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Charger Failure - Charger is off."
::= { lgpFlexConditionsWellKnown 6254 }
lgpCondId6274UnitTopReturnAirSensorFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Return air sensor at the top of the unit is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 6274 }
lgpCondId6275UnitMiddleReturnAirSensorFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Return air sensor in the middle of the unit is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 6275 }
lgpCondId6276UnitBottomReturnAirSensorFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Return air sensor at the bottom of the unit is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 6276 }
lgpCondId6277UnitTopSupplyAirSensorFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Supply air sensor at the top of the unit is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 6277 }
lgpCondId6278UnitMiddleFirstSupplyAirSensorFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"First supply air sensor in the middle of the unit is disconnected
or the signal is out of range."
::= { lgpFlexConditionsWellKnown 6278 }
lgpCondId6279UnitBottomSupplyAirSensorFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Supply air sensor at the bottom of the unit is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 6279 }
lgpCondId6284UnitMiddleSecondSupplyAirSensorFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Second supply air sensor in the middle of the unit is disconnected
or the signal is out of range."
::= { lgpFlexConditionsWellKnown 6284 }
lgpCondId6293ChilledWaterControlActive OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Chilled water inlet temperature control function is enabled due to
'bad' water."
::= { lgpFlexConditionsWellKnown 6293 }
lgpCondId6294ChilledWaterFlowTransducerFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Chilled water flow transducer is disconnected or the signal is out
of range."
::= { lgpFlexConditionsWellKnown 6294 }
lgpCondId6295ChilledWaterInletTemperatureSensorFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Chilled water inlet temperature sensor is disconnected or the
signal is out of range. The sensor is mandatory for the chilled
water flow function."
::= { lgpFlexConditionsWellKnown 6295 }
lgpCondId6296ChilledWaterHighInletTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Chilled water inlet temperature has exceeded an upper threshold."
::= { lgpFlexConditionsWellKnown 6296 }
lgpCondId6297Modbus010VModuleCommunicationFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Modbus 0-10V module for managing the second Chilled Water circuit
valve is disconnected or the signal is out of range."
::= { lgpFlexConditionsWellKnown 6297 }
lgpCondId6299RackDoorsOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Rack doors opened due to supply air temperature exceeding the
[Rack Door Open High Supply Air Temperature Threshold]."
::= { lgpFlexConditionsWellKnown 6299 }
lgpCondId6303TeamStaticPressureSensorFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The team static pressure sensor is disconnected or the signal is
out of range."
::= { lgpFlexConditionsWellKnown 6303 }
lgpCondId6304HeatingLockout OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Heating is shut down and disabled."
::= { lgpFlexConditionsWellKnown 6304 }
lgpCondId6305FreeCoolingStoppedHighRoomTemp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Free cooling is temporarily disabled due to room temperature
exceeding a preset delta above the the set point."
::= { lgpFlexConditionsWellKnown 6305 }
lgpCondId6306ColdAisleTemperatureHumidityTeamSensorFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Cold aisle team sensor measuring air temperature and humidity is
disconnected or the signal is out of range."
::= { lgpFlexConditionsWellKnown 6306 }
lgpCondId6309ColdAisleAirSensorFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Cold aisle sensor measuring air temperature and humidity is
disconnected or the signal is out of range."
::= { lgpFlexConditionsWellKnown 6309 }
lgpCondId6310ChilledWaterInletTemperatureControlActive OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Chilled water inlet temperature control is active."
::= { lgpFlexConditionsWellKnown 6310 }
lgpCondId6313ChilledWaterInletTemperatureSensorFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Chilled water inlet temperature sensor is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 6313 }
lgpCondId6314ChilledWaterOutletTemperatureSensorFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Chilled water outlet temperature sensor is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 6314 }
lgpCondId6315ChilledWaterFlowMeterSensorFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Chilled water flow meter sensor is disconnected or the signal is
out of range."
::= { lgpFlexConditionsWellKnown 6315 }
lgpCondId6333Bypassoutofsync OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Bypass and Inverter inputs are not in sync."
::= { lgpFlexConditionsWellKnown 6333 }
lgpCondId6348SystemOutputoffasrequested OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The UPS has shutdown as requested, i.e., the output is off."
::= { lgpFlexConditionsWellKnown 6348 }
lgpCondId6349SystemOffasrequested OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The entire UPS has shutdown as commanded."
::= { lgpFlexConditionsWellKnown 6349 }
lgpCondId6350GeneralFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A general fault in the UPS has been detected."
::= { lgpFlexConditionsWellKnown 6350 }
lgpCondId6351UPSAwaitingPower OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The UPS output is off and the UPS is awaiting the return of input
power."
::= { lgpFlexConditionsWellKnown 6351 }
lgpCondId6352AutonomyCalibration OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Calibration test occurred."
::= { lgpFlexConditionsWellKnown 6352 }
lgpCondId6353GeneralWarning OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A warning in the UPS has been detected."
::= { lgpFlexConditionsWellKnown 6353 }
lgpCondId6354BatteryCharging OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The UPS battery is charging (battery charge percentage lower than
98)."
::= { lgpFlexConditionsWellKnown 6354 }
lgpCondId6355BackfeedRelayFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Bypass SCR is wrongly on or commutated."
::= { lgpFlexConditionsWellKnown 6355 }
lgpCondId6356BatteryCircuitOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Battery Circuit Open."
::= { lgpFlexConditionsWellKnown 6356 }
lgpCondId6357SystemRestartPending OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A request for UPS restart has been received."
::= { lgpFlexConditionsWellKnown 6357 }
lgpCondId6358PipeTemperatureSensorFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Air temperature sensor located in the pipe is not sending a valid
value."
::= { lgpFlexConditionsWellKnown 6358 }
lgpCondId6362SFAReservedEvent26 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6362 }
lgpCondId6363SFAReservedEvent27 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6363 }
lgpCondId6364SFAReservedEvent28 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6364 }
lgpCondId6365SFAReservedEvent29 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6365 }
lgpCondId6366SFAReservedEvent30 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6366 }
lgpCondId6367SFAReservedEvent31 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6367 }
lgpCondId6368SFAReservedEvent32 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6368 }
lgpCondId6369SFAReservedEvent33 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6369 }
lgpCondId6370SFAReservedEvent34 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6370 }
lgpCondId6371SFAReservedEvent35 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6371 }
lgpCondId6372SFAReservedEvent36 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6372 }
lgpCondId6373SFAReservedEvent37 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6373 }
lgpCondId6374SFAReservedEvent38 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6374 }
lgpCondId6375SFAReservedEvent39 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6375 }
lgpCondId6376SFAReservedEvent40 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6376 }
lgpCondId6377SFAReservedEvent41 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6377 }
lgpCondId6378SFAReservedEvent42 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6378 }
lgpCondId6379SFAReservedEvent43 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6379 }
lgpCondId6380SFAReservedEvent44 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6380 }
lgpCondId6381SFAReservedEvent45 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6381 }
lgpCondId6382SFAReservedEvent46 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6382 }
lgpCondId6383SFAReservedEvent47 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6383 }
lgpCondId6384SFAReservedEvent48 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6384 }
lgpCondId6385SFAReservedEvent49 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6385 }
lgpCondId6386SFAReservedEvent50 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Reserved event for SFA use."
::= { lgpFlexConditionsWellKnown 6386 }
lgpCondId6438PowerModuleInputCurrentAbnormal OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Input current of the power module is abnormal."
::= { lgpFlexConditionsWellKnown 6438 }
lgpCondId6439PowerModuleBalancerofDCBusFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Balancer of DC Bus in the power module has failed."
::= { lgpFlexConditionsWellKnown 6439 }
lgpCondId6440PowerModuleFuseFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A summary event indicating one or more fuse failures in the power
module."
::= { lgpFlexConditionsWellKnown 6440 }
lgpCondId6441PowerModulePowerSupplyFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Power module power supply failure."
::= { lgpFlexConditionsWellKnown 6441 }
lgpCondId6450PDUPoweredOn OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The PDU was powered on."
::= { lgpFlexConditionsWellKnown 6450 }
lgpCondId6453InputWiringFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The neutral/ground conductors on the input wiring are not properly
bonded, or the line/neutral conductors have been swapped."
::= { lgpFlexConditionsWellKnown 6453 }
lgpCondId6454DCtoDCConverterFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A failure has occurred in the battery discharge circuit."
::= { lgpFlexConditionsWellKnown 6454 }
lgpCondId6455LeakSensorCableFault OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A fault is detected in the 'Leak Sensor' cable."
::= { lgpFlexConditionsWellKnown 6455 }
lgpCondId6518StandbyUnitActivatedDuetoChillerFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"External chiller unit has failed for this unit, so the standby
cooling unit has been activated."
::= { lgpFlexConditionsWellKnown 6518 }
lgpCondId6522PDUResidualOverCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a PDU residual over current condition."
::= { lgpFlexConditionsWellKnown 6522 }
lgpCondId6527PDUOverCurrentProtection OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The PDU over current protection is triggered."
::= { lgpFlexConditionsWellKnown 6527 }
lgpCondId6528PowerModuleLeverUnlocked OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The power module is inactive because the lever is in the unlocked
position."
::= { lgpFlexConditionsWellKnown 6528 }
lgpCondId6529HardwareMismatch OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The assigned system model settings do not match the actual
installed hardware. The module count is wrong, or a module of the
wrong type is installed."
::= { lgpFlexConditionsWellKnown 6529 }
lgpCondId6530SupplyNTCAirSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The supply NTC air sensor is disconnected or the signal is out of
range."
::= { lgpFlexConditionsWellKnown 6530 }
lgpCondId6531ExternalAirSensorCIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external air sensor C is disconnected or the signal is out of
range."
::= { lgpFlexConditionsWellKnown 6531 }
lgpCondId6532ExternalAirSensorDIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external air sensor D is disconnected or the signal is out of
range."
::= { lgpFlexConditionsWellKnown 6532 }
lgpCondId6533ExternalAirSensorEIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The external air sensor E is disconnected or the signal is out of
range."
::= { lgpFlexConditionsWellKnown 6533 }
lgpCondId6534PumpThermalOverload OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Pump is shut down due to thermal overload."
::= { lgpFlexConditionsWellKnown 6534 }
lgpCondId6535XDModuleCommunicationLost OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Communication with XD Module has been lost."
::= { lgpFlexConditionsWellKnown 6535 }
lgpCondId6536MMSCapacityExceeded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The critical load is larger than the redundant rating of a 1+N
redundant multi-module system."
::= { lgpFlexConditionsWellKnown 6536 }
lgpCondId6538TSAControlInputIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The analog input used to set the air temperature set point for
cooling control is disconnected or the signal is out of range."
::= { lgpFlexConditionsWellKnown 6538 }
lgpCondId6539ChilledWaterValveHoursExceeded OBJECT-IDENTITY
STATUS current
DESCRIPTION
"[Chilled Water Valve Hours] has exceeded [Chilled Water Valve
Operating Hours Threshold]."
::= { lgpFlexConditionsWellKnown 6539 }
lgpCondId6540FSAControlInputIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The analog input used to set the air temperature set point for fan
speed control is disconnected or the signal is out of range."
::= { lgpFlexConditionsWellKnown 6540 }
lgpCondId6541AutoTuneLicenseExpiring OBJECT-IDENTITY
STATUS current
DESCRIPTION
"License for the AutoTune feature has not been refreshed in 30 days
and will be expiring soon."
::= { lgpFlexConditionsWellKnown 6541 }
lgpCondId6542AutoTuneLicenseExpired OBJECT-IDENTITY
STATUS current
DESCRIPTION
"License for the AutoTune feature has expired."
::= { lgpFlexConditionsWellKnown 6542 }
lgpCondId6543UnitInStandbyDueToCoolingLoss OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Unit forced into standby because it is unable to provide any
cooling."
::= { lgpFlexConditionsWellKnown 6543 }
lgpCondId6544ControlUnitsRemoteShutdownMismatch OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The remote shutdown status of the primary control unit does not
match the remote shutdown status of the secondary control unit."
::= { lgpFlexConditionsWellKnown 6544 }
lgpCondId6545SecondaryControlUnitCommunicationLost OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The primary control unit has lost Ethernet communications with the
secondary control unit."
::= { lgpFlexConditionsWellKnown 6545 }
lgpCondId6546ControlUnitsUnitCodeMismatch OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Unit codes for the primary and secondary control units do not
match."
::= { lgpFlexConditionsWellKnown 6546 }
lgpCondId6547SSAControlInputIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The analog input used to set the static pressure set point for fan
speed control is disconnected or the signal is out of range."
::= { lgpFlexConditionsWellKnown 6547 }
lgpCondId6574SubfeedPhaseUndercurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Subfeed breaker phase current has dropped below the threshold."
::= { lgpFlexConditionsWellKnown 6574 }
lgpCondId6587TransferCountCleared OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A system event indicating the transfer count has been cleared."
::= { lgpFlexConditionsWellKnown 6587 }
lgpCondId6588EnergyCounterCleared OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A system event indicating the energy counter (e.g. KWH) has been
cleared."
::= { lgpFlexConditionsWellKnown 6588 }
lgpCondId6589HistoryLogsFull OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The history logs are full."
::= { lgpFlexConditionsWellKnown 6589 }
lgpCondId6590HistoryLogsCleared OBJECT-IDENTITY
STATUS current
DESCRIPTION
"History logs have been cleared."
::= { lgpFlexConditionsWellKnown 6590 }
lgpCondId6591EventLogCleared OBJECT-IDENTITY
STATUS current
DESCRIPTION
"All past alarms and faults have been cleared."
::= { lgpFlexConditionsWellKnown 6591 }
lgpCondId6592SystemDateChanged OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system date has been updated."
::= { lgpFlexConditionsWellKnown 6592 }
lgpCondId6593SystemTimeChanged OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system time has been updated."
::= { lgpFlexConditionsWellKnown 6593 }
lgpCondId6594AccessPasswordChanged OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The access password has been changed."
::= { lgpFlexConditionsWellKnown 6594 }
lgpCondId6595ConfigModified OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A setpoint has been updated."
::= { lgpFlexConditionsWellKnown 6595 }
lgpCondId6612SCRShort OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The SCR is in a short condition."
::= { lgpFlexConditionsWellKnown 6612 }
lgpCondId6613SCROpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The SCR is in an open condition."
::= { lgpFlexConditionsWellKnown 6613 }
lgpCondId6614ACPowerSupplyFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A failure of the AC Power Supply has been detected."
::= { lgpFlexConditionsWellKnown 6614 }
lgpCondId6615DCPowerSupplyFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A failure of the DC Power Supply has been detected."
::= { lgpFlexConditionsWellKnown 6615 }
lgpCondId6616VoltageSensorFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A voltage sensor failure has been detected."
::= { lgpFlexConditionsWellKnown 6616 }
lgpCondId6617SCRSensorFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The SCR sensor module failed."
::= { lgpFlexConditionsWellKnown 6617 }
lgpCondId6618CurrentSensorFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The current sensor module failed."
::= { lgpFlexConditionsWellKnown 6618 }
lgpCondId6619GateDriveFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The Gate Drive module failed."
::= { lgpFlexConditionsWellKnown 6619 }
lgpCondId6620SurgeFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The surge module failed for the input source."
::= { lgpFlexConditionsWellKnown 6620 }
lgpCondId6621FastUnderVoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Fast under voltage detected."
::= { lgpFlexConditionsWellKnown 6621 }
lgpCondId6622SlowUnderVoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Slow under voltage detected."
::= { lgpFlexConditionsWellKnown 6622 }
lgpCondId6623OverVoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Over voltage detected."
::= { lgpFlexConditionsWellKnown 6623 }
lgpCondId6624OverUnderFrequencyFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An over or under frequency condition has been detected."
::= { lgpFlexConditionsWellKnown 6624 }
lgpCondId6625GeneralSourceFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A non-specific failure has been detected in the source."
::= { lgpFlexConditionsWellKnown 6625 }
lgpCondId6626OverCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"An over current has been detected."
::= { lgpFlexConditionsWellKnown 6626 }
lgpCondId6627PeakCurrentOffLimit OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The peak current has exceeded the setpoint defined by I-PK Xfer
Lockout."
::= { lgpFlexConditionsWellKnown 6627 }
lgpCondId6628SyncFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A phase rotation/out of synchronization failure has been detected."
::= { lgpFlexConditionsWellKnown 6628 }
lgpCondId6629InputOverVoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Input over voltage."
::= { lgpFlexConditionsWellKnown 6629 }
lgpCondId6630InputUnderVoltage OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Input under voltage."
::= { lgpFlexConditionsWellKnown 6630 }
lgpCondId6631InputOverUnderFrequency OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Input over/under frequency."
::= { lgpFlexConditionsWellKnown 6631 }
lgpCondId6635VoltageSenseFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Output voltage sense failure."
::= { lgpFlexConditionsWellKnown 6635 }
lgpCondId6636LoadonAlternateSource OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The load is on the alternate source."
::= { lgpFlexConditionsWellKnown 6636 }
lgpCondId6637UnderVoltageFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Output under voltage failure."
::= { lgpFlexConditionsWellKnown 6637 }
lgpCondId6638OutputOverCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Output is over current."
::= { lgpFlexConditionsWellKnown 6638 }
lgpCondId6639GroundOverCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Ground is over current."
::= { lgpFlexConditionsWellKnown 6639 }
lgpCondId6640NeutralOverCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Neutral is over current."
::= { lgpFlexConditionsWellKnown 6640 }
lgpCondId6641LoadVoltageTHD OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Load voltage THD has exceeded the set limit."
::= { lgpFlexConditionsWellKnown 6641 }
lgpCondId6662ControlLogicFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A control logic module has failed."
::= { lgpFlexConditionsWellKnown 6662 }
lgpCondId6663PowerSupplyLogicFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"A power supply module has failed."
::= { lgpFlexConditionsWellKnown 6663 }
lgpCondId6664ExternalCommsFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"External communications failure."
::= { lgpFlexConditionsWellKnown 6664 }
lgpCondId6665HeatSinkOverTemp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system heat sink temperature has exceeded design limits."
::= { lgpFlexConditionsWellKnown 6665 }
lgpCondId6666AutomaticTransferInhibited OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Automatic transfer is inhibited."
::= { lgpFlexConditionsWellKnown 6666 }
lgpCondId6667InputSourceTransferInhibited OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Input source transfer is inhibited."
::= { lgpFlexConditionsWellKnown 6667 }
lgpCondId6676CB1ShuntTrip OBJECT-IDENTITY
STATUS current
DESCRIPTION
"CB1 Shunt Trip event."
::= { lgpFlexConditionsWellKnown 6676 }
lgpCondId6677CB2ShuntTrip OBJECT-IDENTITY
STATUS current
DESCRIPTION
"CB2 Shunt Trip event."
::= { lgpFlexConditionsWellKnown 6677 }
lgpCondId6678CB6NeutralOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"CB6 neutral open event."
::= { lgpFlexConditionsWellKnown 6678 }
lgpCondId6679ContactorNeutralFail OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Contactor Neutral Fail event."
::= { lgpFlexConditionsWellKnown 6679 }
lgpCondId6680CB1BreakerOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"CB1 Breaker open event. Normal state is breaker closed. Latched
state is breaker open."
::= { lgpFlexConditionsWellKnown 6680 }
lgpCondId6681CB2BreakerOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"CB2 Breaker open event. Normal state is breaker closed. Latched
state is breaker open."
::= { lgpFlexConditionsWellKnown 6681 }
lgpCondId6682CB4BreakerClosed OBJECT-IDENTITY
STATUS current
DESCRIPTION
"CB4 breaker closed event. Normal state is breaker open. Latched
state is breaker closed."
::= { lgpFlexConditionsWellKnown 6682 }
lgpCondId6683CB5BreakerClosed OBJECT-IDENTITY
STATUS current
DESCRIPTION
"CB5 breaker closed event. Normal state is breaker open. Latched
state is breaker closed."
::= { lgpFlexConditionsWellKnown 6683 }
lgpCondId6684CB3BreakerOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"CB3 breaker open event. Normal state is breaker closed. Latched
state is breaker open."
::= { lgpFlexConditionsWellKnown 6684 }
lgpCondId6685CB3ABreakerOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"CB3A breaker open event. Normal state is breaker closed. Latched
state is breaker open."
::= { lgpFlexConditionsWellKnown 6685 }
lgpCondId6686CB6BreakerOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"CB6 breaker open event. Normal state is breaker closed. Latched
state is breaker open."
::= { lgpFlexConditionsWellKnown 6686 }
lgpCondId6687CB7BreakerOpen OBJECT-IDENTITY
STATUS current
DESCRIPTION
"CB7 breaker open event. Normal state is breaker closed. Latched
state is breaker open."
::= { lgpFlexConditionsWellKnown 6687 }
lgpCondId6691GroupIndependentOn OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The group standby/cascade state for this unit has been overridden.
The unit has been forced on."
::= { lgpFlexConditionsWellKnown 6691 }
lgpCondId6692GroupIndependentOff OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The group standby/cascade state for this unit has been overridden.
The unit has been forced off."
::= { lgpFlexConditionsWellKnown 6692 }
lgpCondId6693BranchResidualOverCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a branch residual over current condition."
::= { lgpFlexConditionsWellKnown 6693 }
lgpCondId6694ReceptacleResidualOverCurrent OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The system has detected a receptacle residual over current
condition."
::= { lgpFlexConditionsWellKnown 6694 }
lgpCondId6728BuckOn OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The input voltage is currently being bucked (lowered) by the
inverter."
::= { lgpFlexConditionsWellKnown 6728 }
lgpCondId6729BoostOn OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The input voltage is currently being boosted (raised) by the
inverter."
::= { lgpFlexConditionsWellKnown 6729 }
lgpCondId6739Compressor1HighPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor 1 High Pressure."
::= { lgpFlexConditionsWellKnown 6739 }
lgpCondId6740Compressor2HighPressure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor 2 High Pressure."
::= { lgpFlexConditionsWellKnown 6740 }
lgpCondId6741Compressor1ThermalOverload OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor 1 Thermal Overload."
::= { lgpFlexConditionsWellKnown 6741 }
lgpCondId6742Compressor2ThermalOverload OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor 2 Thermal Overload."
::= { lgpFlexConditionsWellKnown 6742 }
lgpCondId6758CompressorFreezeProtection OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Compressor has entered the freeze protection phase."
::= { lgpFlexConditionsWellKnown 6758 }
lgpCondId6773FanTemperatureCompensationLimitReached OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Unit is configured for fan temperature compensation, and the fan
control set point cannot be reduced any further due to high
remote air temperature sensor readings."
::= { lgpFlexConditionsWellKnown 6773 }
lgpCondId6774ModbusECFanCommunicationLost OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Communication with Modbus EC fan has been lost."
::= { lgpFlexConditionsWellKnown 6774 }
lgpCondId6785AnalogTemperatureControlIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Analog input used for creating the control temperature (instead of
reading a sensor) is disconnected or the signal is out of range."
::= { lgpFlexConditionsWellKnown 6785 }
lgpCondId6786SubgroupFirmwareUpdateRequired OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Mismatch of subgroup firmware. Both the primary and secondary
control boards must be running the same firmware version."
::= { lgpFlexConditionsWellKnown 6786 }
lgpCondId6787SubgroupSecondaryControlUnitIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Subgroup secondary control unit is reporting an unspecified issue."
::= { lgpFlexConditionsWellKnown 6787 }
lgpCondId6788EEVCommunicationLost OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Communication with Electronic Expansion Valve unit has been lost."
::= { lgpFlexConditionsWellKnown 6788 }
lgpCondId6789EEVMotorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Electronic Expansion Valve stepper motor issue."
::= { lgpFlexConditionsWellKnown 6789 }
lgpCondId6790EEVFeedbackIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Electronic Expansion Valve feedback error."
::= { lgpFlexConditionsWellKnown 6790 }
lgpCondId6791EEVPressureSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Electronic Expansion Valve refrigerant pressure sensor is
disconnected or the signal is out of range."
::= { lgpFlexConditionsWellKnown 6791 }
lgpCondId6792EEVCoilTemperatureSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Electronic Expansion Valve coil temperature sensor is disconnected
or the signal is out of range."
::= { lgpFlexConditionsWellKnown 6792 }
lgpCondId6793EEVDischargeTemperatureSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Electronic Expansion Valve discharge temperature sensor is
disconnected or the signal is out of range."
::= { lgpFlexConditionsWellKnown 6793 }
lgpCondId6794EEVSumpTemperatureSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Electronic Expansion Valve sump temperature sensor is disconnected
or the signal is out of range."
::= { lgpFlexConditionsWellKnown 6794 }
lgpCondId6795EEVBatteryTestIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Electronic Expansion Valve battery state cannot be determined."
::= { lgpFlexConditionsWellKnown 6795 }
lgpCondId6796EEVBatteryPersistentIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Electronic Expansion Valve has continuously detected a 'bad'
battery condition for an extended period of time."
::= { lgpFlexConditionsWellKnown 6796 }
lgpCondId6798PumpCycleLockOut OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Pump is locked out due to multiple pump-to-compressor transitions
at cold ambient air temperature."
::= { lgpFlexConditionsWellKnown 6798 }
lgpCondId6799PumpBoardFirmwareUpdateRequired OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Mismatch of pump board firmware. All pump boards must be running
the same firmware version."
::= { lgpFlexConditionsWellKnown 6799 }
lgpCondId6800PumpControlBoardIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Pump is shut down due to a pump control board issue. Control
board must be rebooted."
::= { lgpFlexConditionsWellKnown 6800 }
lgpCondId6801PumpInvalidDataShutdown OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Pump is shut down due to invalid data."
::= { lgpFlexConditionsWellKnown 6801 }
lgpCondId6802PumpInputPressureSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Pump input refrigerant pressure sensor is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 6802 }
lgpCondId6803PumpInputTemperatureSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Pump input refrigerant temperature sensor is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 6803 }
lgpCondId6804PumpOutputPressureSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Pump output refrigerant pressure sensor is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 6804 }
lgpCondId6805PumpOutputTemperatureSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Pump output refrigerant temperature sensor is disconnected or the
signal is out of range."
::= { lgpFlexConditionsWellKnown 6805 }
lgpCondId6806PumpCommunicationLost OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Communication with pump unit has been lost."
::= { lgpFlexConditionsWellKnown 6806 }
lgpCondId6807PumpRemoteShutdown OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Pump is shut down by a remote signal."
::= { lgpFlexConditionsWellKnown 6807 }
lgpCondId6808PumpUSBEthernetPortIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Pump control board USB or Ethernet interface has failed."
::= { lgpFlexConditionsWellKnown 6808 }
lgpCondId6809PumpStartupFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Multiple attempts to start the pump have failed."
::= { lgpFlexConditionsWellKnown 6809 }
lgpCondId6810PumpInverterFailure OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Pump inverter is reporting a failure."
::= { lgpFlexConditionsWellKnown 6810 }
lgpCondId6811PumpTVSSIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Pump Transient Voltage Surge Suppressor or Surge Protection Device
has failed."
::= { lgpFlexConditionsWellKnown 6811 }
lgpCondId6812PumpHighSuperheat OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Pump inlet refrigerant superheat temperature is too high, or the
pump has been running too long with the condenser fan off."
::= { lgpFlexConditionsWellKnown 6812 }
lgpCondId6813CondenserHighAmbientAirTempDelta OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The difference between condenser measured ambient air temperatures
has been too large for an extended period of time."
::= { lgpFlexConditionsWellKnown 6813 }
lgpCondId6814CondenserLeeTempOptionMismatch OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Lee-Temp option configured at a condenser unit does not match Lee
-Temp option configured at the control unit."
::= { lgpFlexConditionsWellKnown 6814 }
lgpCondId6815CondenserBoardFirmwareUpdateRequired OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Mismatch of condenser board firmware. All condenser boards must
be running the same firmware version."
::= { lgpFlexConditionsWellKnown 6815 }
lgpCondId6816CondenserToPumpHighRefrigerantTempDelta OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Temperature delta between the condenser output refrigerant and
pump inlet refrigerant is too large."
::= { lgpFlexConditionsWellKnown 6816 }
lgpCondId6817CondenserRefrigerantTypeMismatch OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Refrigerant type configured at condenser unit does not match
refrigerant type configured at the control unit."
::= { lgpFlexConditionsWellKnown 6817 }
lgpCondId6818ExternalSupplyFluidHighTemperature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Supply fluid temperature has exceeded a threshold, as indicated by
an external input signal."
::= { lgpFlexConditionsWellKnown 6818 }
lgpCondId6819ExternalSupplyFluidTempSensorIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Supply fluid temperature sensor is disconnected or the signal is
out of range, as indicated by an external input signal."
::= { lgpFlexConditionsWellKnown 6819 }
lgpCondId6822AuditLogUpdate OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Audit log has been updated."
::= { lgpFlexConditionsWellKnown 6822 }
lgpCondId6824ExternalSupplyFluidFlowIssue OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Supply fluid flow issue, as indicated by an external input signal."
::= { lgpFlexConditionsWellKnown 6824 }
END
|