summaryrefslogtreecommitdiff
path: root/MIBS/infinera/LUM-INVENTORY-MIB
blob: 9a72cf250442de850115d5dd6e3ac15c5c937b57 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
LUM-INVENTORY-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
    Unsigned32, Integer32, Counter32
        FROM SNMPv2-SMI
    OBJECT-GROUP, NOTIFICATION-GROUP, MODULE-COMPLIANCE
        FROM SNMPv2-CONF
    TEXTUAL-CONVENTION, AutonomousType, TruthValue,
    DateAndTime, TestAndIncr, DisplayString, RowPointer
        FROM SNMPv2-TC
    SnmpAdminString
        FROM SNMP-FRAMEWORK-MIB
    lumModules, lumInventoryMIB
        FROM LUM-REG
    MgmtNameString
        FROM LUM-TC;

lumInventoryMIBModule MODULE-IDENTITY
    LAST-UPDATED
        "201706150000Z" -- June 15th 2017
    ORGANIZATION
        "Infinera Corporation"
    CONTACT-INFO
        "techsupport@infinera.com"
    DESCRIPTION
        "The inventory MIB.

        In large parts modeled after the Entity MIB
        version 2 see RFC2737.

        - General

        - Physical entitites

"
    REVISION
        "201706150000Z" -- June 15th 2017
    DESCRIPTION
        "Changes made for release r29.0:
         - Changed ORGANIZATION and CONTACT-INFO"
    REVISION
        "201409300000Z" -- Sep 30th 2014
    DESCRIPTION
        "Set invPhysVendorType to deprecated since it is not
        used any more."
    REVISION
        "200509140000Z" -- September 14th 2005
    DESCRIPTION
        "Added minimal compliance groups."
    REVISION
        "200409300000Z" -- September 30th 2004
    DESCRIPTION
        "Added table sizes."
    REVISION
        "200203080000Z" -- March 8th 2002
    DESCRIPTION
        "Put back softwareRev."
    REVISION
        "200110300000Z" -- October 30th 2001
    DESCRIPTION
        "MIB version and testAndIncr hidden - not supported yet.
        Changed lastChange to DateAndTime."
    REVISION
        "200107170000Z" -- July 17th 2001
    DESCRIPTION
        "Added notifications. Added general group with version
        and testAndIncr.
        Added addtional alias and persistence
        meta-information."
    REVISION
        "200105110000Z" -- May 11th 2001
    DESCRIPTION
        "Replaced softwareRev with productDataRev.
        Removed alias and assetId."
    REVISION
        "200105100000Z" -- May 10th 2001
    DESCRIPTION
        "The initial revision of this module."
    ::= { lumModules 5 }

-- tbd Further work: Add user configurable asset id for physical entities(?)
-- tbd Further work: Add timestamp on physical entries and the notifications
-- ... created and lastChange, or is it sufficient with just lastChangeTime?


-- ----------------------------------------------------
-- Conformance area, containing groups and complicance
-- specifications.
-- ----------------------------------------------------

lumInventoryConfs OBJECT IDENTIFIER ::= { lumInventoryMIB 1 }
lumInventoryGroups OBJECT IDENTIFIER ::= { lumInventoryConfs 1 }
lumInventoryCompl OBJECT IDENTIFIER ::= { lumInventoryConfs 2 }
lumInventoryMinimalGroups OBJECT IDENTIFIER ::= { lumInventoryConfs 3 }
lumInventoryMinimalCompl OBJECT IDENTIFIER ::= { lumInventoryConfs 4 }


-- ----------------------------------------------------
-- Root for objects in the inventory MIB
-- ----------------------------------------------------

lumInventoryMIBObjects OBJECT IDENTIFIER ::= { lumInventoryMIB 2 }


-- ----------------------------------------------------
-- This MIB contains the following groups:
-- ----------------------------------------------------

invPhysical OBJECT IDENTIFIER ::= { lumInventoryMIBObjects 1 }
invGeneral OBJECT IDENTIFIER ::= { lumInventoryMIBObjects 2 }
lumentisInvNotifications  OBJECT IDENTIFIER ::= { lumInventoryMIBObjects 3 }
invEntities  OBJECT IDENTIFIER ::= { lumInventoryMIBObjects 4 }
invRelations  OBJECT IDENTIFIER ::= { lumInventoryMIBObjects 5 }
invInsRemLog    OBJECT IDENTIFIER ::= { lumInventoryMIBObjects 6 }

-- ----------------------------------------------------
-- Textual Conventions
-- ----------------------------------------------------

PhysicalClass ::= TEXTUAL-CONVENTION
    STATUS            current
    DESCRIPTION
            "An enumerated value which provides an
            indication of the general hardware type
            of a particular physical entity.
            There are no restrictions as to the number of
            invPhysicalEntries of each invPhysicalClass,
            which must be instantiated by an agent.

            The enumeration 'other' is applicable if the
            physical entity class is known, but does not
            match any of the supported values.

            The enumeration 'unknown' is applicable if
            the physical entity class is unknown to the
            agent.

            The enumeration 'chassis' is applicable if the physical
            entity class is an overall container for networking
            equipment.  Any class of physical entity except a stack may
            be contained within a chassis, and a chassis may only be
            contained within a stack.

            The enumeration 'backplane' is applicable if the physical
            entity class is some sort of device for aggregating and
            forwarding networking traffic, such as a shared backplane in
            a modular ethernet switch.  Note that an agent may model a
            backplane as a single physical entity, which is actually
            implemented as multiple discrete physical components (within
            a chassis or stack).

            The enumeration 'container' is applicable if the physical
            entity class is capable of containing one or more removable
            physical entities, possibly of different types. For example,
            each (empty or full) slot in a chassis will be modeled as a
            container. Note that all removable physical entities should
            be modeled within a container entity, such as field-
            replaceable modules, fans, or power supplies.  Note that all
            known containers should be modeled by the agent, including
            empty containers.

            The enumeration 'powerSupply' is applicable if the physical
            entity class is a power-supplying component.

            The enumeration 'fan' is applicable if the physical entity
            class is a fan or other heat-reduction component.

            The enumeration 'sensor' is applicable if the physical
            entity class is some sort of sensor, such as a temperature
            sensor within a router chassis.

            The enumeration 'module' is applicable if the physical
            entity class is some sort of self-contained sub-system.  If
            it is removable, then it should be modeled within a
            container entity, otherwise it should be modeled directly
            within another physical entity (e.g., a chassis or another
            module).

            The enumeration 'port' is applicable if the physical entity
            class is some sort of networking port, capable of receiving
            and/or transmitting networking traffic.

            The enumeration 'stack' is applicable if the physical entity
            class is some sort of super-container (possibly virtual),
            intended to group together multiple chassis entities.  A
            stack may be realized by a 'virtual' cable, a real
            interconnect cable, attached to multiple chassis, or may in
            fact be comprised of multiple interconnect cables. A stack
            should not be modeled within any other physical entities,
            but a stack may be contained within another stack.  Only
            chassis entities should be contained within a stack."
    SYNTAX      INTEGER  {
       undefined (0),
       other(1),
       unknown(2),
       chassis(3),
       backplane(4),
       container(5),     -- e.g., chassis slot or daughter-card holder
       powerSupply(6),
       fan(7),
       sensor(8),
       module(9),        -- e.g., plug-in card or daughter-card
       port(10),
       stack(11) }       -- e.g., stack of multiple chassis entities

EntityClass ::= TEXTUAL-CONVENTION
    STATUS            current
    DESCRIPTION
        "tbd"
    SYNTAX      INTEGER  {
       undefined (0),
       other(1),
       unknown(2),
       chassis(3),
       backplane(4),
       container(5),    -- e.g., chassis slot or daughter-card holder
       powerSupply(6),
       fan(7),
       sensor(8),
       module(9),       -- e.g., plug-in card or daughter-card
       port(10),
       stack(11),       -- e.g., stack of multiple chassis entities
       logical(12) }    -- e.g. traffic object realized in software }

InsRemEventType ::= TEXTUAL-CONVENTION
    STATUS            current
    DESCRIPTION
        "Type of equipment logging event"
    SYNTAX      INTEGER  {
       insert (0),
       remove (1) }


-- ----------------------------------------------------
-- Physical entities group
-- ----------------------------------------------------

invPhysTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF InvPhysEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "This table contains one row per physical
            entity.  There is always at least one row
            for an 'overall' physical entity."
    ::= { invPhysical 1 }

invPhysEntry OBJECT-TYPE
    SYNTAX      InvPhysEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "Information about a particular physical
            entity.

            Each entry provides objects (invPhysicalDescr,
            invPhysicalVendorType, and invPhysicalClass)
            to help an NMS identify and characterize the
            entry, and objects (invPhysicalContainedIn
            and invPhysicalParentRelPos) to help an NMS
            relate the particular entry to other entries
            in this table.

"
    INDEX   { invPhysIndex }
    ::= { invPhysTable 1 }

InvPhysEntry ::= SEQUENCE {
      invPhysIndex              Unsigned32,
      invPhysDescr              SnmpAdminString,
      invPhysVendorType         AutonomousType,
      invPhysContainedIn        Unsigned32,
      invPhysClass              PhysicalClass,
      invPhysParentRelPos       Integer32,
      invPhysName               MgmtNameString,
      invPhysHardwareRev        SnmpAdminString,
      invPhysFirmwareRev        SnmpAdminString,
      invPhysProductDataRev     SnmpAdminString,
      invPhysSerialNum          SnmpAdminString,
      invPhysMfgName            SnmpAdminString,
      invPhysModelName          SnmpAdminString,
      invPhysIsFRU              TruthValue,
      invPhysSoftwareRev        SnmpAdminString,
      invPhysSoftwareProduct    SnmpAdminString,
      invPhysClei               DisplayString,
      invPhysAid                DisplayString}

invPhysIndex    OBJECT-TYPE
    SYNTAX      Unsigned32 (1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The index for this entry.
"
    ::= { invPhysEntry 1 }

invPhysDescr OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "A textual description of physical entity. This
        object should contain a string which identifies
        the manufacturers name for the physical entity,
        and should be set to a distinct value for each
        version or model of the physical entity.
"
    ::= { invPhysEntry 2 }

invPhysVendorType OBJECT-TYPE
    SYNTAX      AutonomousType
    MAX-ACCESS  read-only
    STATUS      deprecated
    DESCRIPTION
        "An indication of the vendor-specific hardware
        type of the physical entity.  Note that this is
        different from the definition of MIB-IIs
        sysObjectID.

        An agent should set this object to a
        enterprise-specific registration identifier value
        indicating the specific equipment type in detail.
        The associated instance of invPhysClass is used
        to indicate the general type of hardware device.

        If no vendor-specific registration identifier
        exists for this physical entity, or the value
        is unknown by this agent, then the value { 0 0 }
        is returned.
"
    ::= { invPhysEntry 3 }

invPhysContainedIn OBJECT-TYPE
    SYNTAX      Unsigned32 (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of invPhysIndex for the physical
        entity which 'contains' this physical entity.
        A value of zero indicates this physical entity
        is not contained in any other physical entity.
        Note that the set of 'containment' relationships
        define a strict hierarchy; that is, recursion
        is not allowed.

        In the event a physical entity is contained by
        more than one physical entity (e.g., double-wide
        modules), this object should identify the
        containing entity with the lowest value
        of invPhysIndex.
"
    ::= { invPhysEntry 4 }

invPhysClass OBJECT-TYPE
    SYNTAX      PhysicalClass
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An indication of the general hardware type of
        the physical entity.

        An agent should set this object to the standard
        enumeration value which most accurately indicates
        the general class of the physical entity, or the
        primary class if there is more than one.

        If no appropriate standard registration
        identifier exists for this physical entity, then
        the value 'other(1)' is returned. If the value
        is unknown by this agent, then the value
        'unknown(2)' is returned.
"
    ::= { invPhysEntry 5 }

invPhysParentRelPos OBJECT-TYPE
    SYNTAX      Integer32 (-1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An indication of the relative position of this
        'child' component among all its 'sibling'
        components. Sibling components are defined as
        invPhysEntries which share the same instance
        values of each of the invPhysContainedIn
        and invPhysClass objects.

        An NMS can use this object to identify the
        relative ordering for all sibling components
        of a particular parent (identified by the
        invPhysContainedIn instance in each sibling
        entry).

        This value should match any external labeling
        of the physical component if possible. For example,
        for a container (e.g., card slot) labeled as
        'slot #3', invPhysParentRelPos should have the
        value '3'.  Note that the invPhysEntry for the
        module plugged in slot 3 should have an
        invPhysParentRelPos value of '1'.

        If the physical position of this component
        does not match any external numbering or clearly
        visible ordering, then user documentation or
        other external reference material should be
        used to determine the parent-relative position.
        If this is not possible, then the the agent should
        assign a consistent (but possibly arbitrary)
        ordering to a given set of 'sibling' components,
        perhaps based on internal representation of the
        components.

        If the agent cannot determine the parent-relative
        position for some reason, or if the associated
        value of invPhysContainedIn is '0', then the
        value '-1' is returned. Otherwise a non-negative
        integer is returned, indicating the parent-relative
        position of this physical entity.

        Parent-relative ordering normally starts from
        '1' and continues to 'N', where 'N' represents
        the highest positioned child entity.  However,
        if the physical entities (e.g., slots) are labeled
        from a starting position of zero, then the first
        sibling should be associated with a
        invPhysParentRelPos value of '0'.  Note that this
        ordering may be sparse or dense, depending on agent
        implementation.

        The actual values returned are not globally
        meaningful, as each 'parent' component may use
        different numbering algorithms. The ordering is
        only meaningful among siblings of the same parent
        component.

        The agent should retain parent-relative position
        values across reboots, either through algorithmic
        assignment or use of non-volatile storage.
"
    ::= { invPhysEntry 6 }

invPhysName OBJECT-TYPE
    SYNTAX      MgmtNameString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The textual name of the physical entity.  The
        value of this object should be the name of the
        component as assigned by the local device and
        should be suitable for use in commands entered
        at the 'console' of the device.  This might be a
        text name, such as 'console' or a simple component
        number (e.g., port or module number), such as '1',
        depending on the physical component naming syntax
        of the device.

        If there is no local name, or this object is
        otherwise not applicable, then this object
        contains a zero-length string.

        Note that the value of invPhysName for two
        physical entities will be the same in the event
        that the console interface does not distinguish
        between them, e.g., slot-1 and the card in slot-1.
"
    ::= { invPhysEntry 7 }

invPhysHardwareRev    OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The vendor-specific hardware revision string for
        the physical entity.  The preferred value is the
        hardware revision identifier actually printed on
        the component itself (if present).

        Note that if revision information is stored
        internally in a non-printable (e.g., binary)
        format, then the agent must convert such
        information to a printable format, in an
        implementation-specific manner.

        If no specific hardware revision string is
        associated with the physical component, or this
        information is unknown to the agent, then this
        object will contain a zero-length string.
"
    ::= { invPhysEntry 8 }

invPhysFirmwareRev    OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The vendor-specific firmware revision string for
        the physical entity.

        Note that if revision information is stored
        internally in a non-printable (e.g., binary)
        format, then the agent must convert such
        information to a printable format, in an
        implementation-specific manner.

        If no specific firmware programs are associated
        with the physical component, or this information
        is unknown to the agent, then this object will
        contain a zero-length string.
"
    ::= { invPhysEntry 9 }

invPhysProductDataRev    OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The vendor-specific product data revision string
        for the physical entity.

        Note that if revision information is stored
        internally in a non-printable (e.g., binary)
        format, then the agent must convert such
        information to a printable format, in an
        implementation-specific manner.

        If no specific software programs are associated
        with the physical component, or this information
        is unknown to the agent, then this object will
        contain a zero-length string.
"
    ::= { invPhysEntry 10 }

invPhysSerialNum   OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The vendor-specific serial number string for the
        physical entity.  The preferred value is the
        serial number string actually printed on the
        component itself (if present).

        On the first instantiation of an physical entity,
        the value of invPhysSerialNum associated with
        that entity is set to the correct vendor-assigned
        serial number, if this information is available
        to the agent.  If a serial number is unknown or
        non-existent, the invPhysSerialNum will be
        set to a zero-length string instead.
"
    ::= { invPhysEntry 11 }

invPhysMfgName   OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The name of the manufacturer of this physical
        component. The preferred value is the manufacturer
        name string actually printed on the component
        itself (if present).

        If the manufacturer name string associated with
        the physical component is unknown to the agent,
        then this object will contain a zero-length
        string.
"
    ::= { invPhysEntry 12 }

invPhysModelName   OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The vendor-specific model name identifier string
        associated with this physical component. The
        preferred value is the customer-visible
        product/part number, which may be printed on the
        component itself.

        If the model name string associated with the
        physical component is unknown to the agent,
        then this object will contain a zero-length string.
"
    ::= { invPhysEntry 13 }

invPhysIsFRU OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates whether or not this
        physical entity is considered a 'field replaceable
        unit' by the vendor.  If this object contains
        the value 'true(1)' then this invPhysEntry
        identifies a field replaceable unit.  For all
        invPhysEntries which represent components that
        are permanently contained within a field
        replaceable unit, the value 'false(2)' should
        be returned for this object.
"
    ::= { invPhysEntry 14 }

invPhysSoftwareRev    OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The vendor-specific software revision string
        for the physical entity.

        If no specific software revision string is
        associated with the physical component, or
        this information is unknown to the agent, then
        this object will contain a zero-length string.
"
    ::= { invPhysEntry 15 }

invPhysSoftwareProduct    OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The vendor-specific software part/product number
        string for the physical entity.

        If no specific software part/product number
        string is associated with the physical component,
        or this information is unknown to the agent,
        then this object will contain a zero-length string.
"
    ::= { invPhysEntry 16 }

invPhysClei OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..10))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The Common Language Equipment Identifier (CLEI)
         code for the product.
         The format is according to RFC 4152.

"
    ::= { invPhysEntry 17 }

invPhysAid OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The access identifier (AID) of the equipment.
         The format is according to GR-833.

"
    ::= { invPhysEntry 18 }

-- ----------------------------------------------------
-- General group
-- ----------------------------------------------------

invGeneralLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time the inventory list was last changed.
"
    ::= { invGeneral 1 }

invGeneralTestAndIncr OBJECT-TYPE
    SYNTAX      TestAndIncr
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Protection against simultaneous access from
        multiple managers. See SNMPv2-TC.
"
    ::= { invGeneral 2 }

invGeneralMibSpecVersion OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The version of the MIB specification.
"
    DEFVAL { "" }
    ::= { invGeneral 3 }

invGeneralMibImplVersion OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The version of the MIB implementation.
"
    DEFVAL { "" }
    ::= { invGeneral 4 }

invGeneralConfigLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the configuration of the MIB was
        last changed.
"
    ::= { invGeneral 5 }

invGeneralPhysTableSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of rows available in the
        physical entities list.
"
    ::= { invGeneral 6 }

invGeneralEntityTableSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of rows available in the
        logical entity list.
"
    ::= { invGeneral 7 }

invGeneralRelationTableSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of rows available in the
        relation list.
"
    ::= { invGeneral 8 }

invGeneralInsRemTableSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of rows available in the
        insert and remove list.
"
    ::= { invGeneral 9 }

invGeneralInsRemLastSeqNumber OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The sequence number last used when creating
        a new entry in the insert remove log.

"
    ::= { invGeneral 10 }

-- ----------------------------------------------------
-- Notifications
-- ----------------------------------------------------

invNotifyPrefix OBJECT IDENTIFIER ::= { lumentisInvNotifications 0 }

invNotificationPhysAdded NOTIFICATION-TYPE
    OBJECTS {
        invPhysIndex,
        invPhysDescr,
        invPhysVendorType,
        invPhysContainedIn,
        invPhysClass,
        invPhysParentRelPos,
        invPhysName,
        invPhysHardwareRev,
        invPhysFirmwareRev,
        invPhysProductDataRev,
        invPhysSerialNum,
        invPhysMfgName,
        invPhysModelName,
        invPhysIsFRU }
    STATUS      current
    DESCRIPTION
        "Sent when a physical entity is added to the
        inventory.

"
    ::= { invNotifyPrefix 1 }

invNotificationPhysRemoved NOTIFICATION-TYPE
    OBJECTS {
        invPhysIndex,
        invPhysDescr,
        invPhysVendorType,
        invPhysContainedIn,
        invPhysClass,
        invPhysParentRelPos,
        invPhysName,
        invPhysHardwareRev,
        invPhysFirmwareRev,
        invPhysProductDataRev,
        invPhysSerialNum,
        invPhysMfgName,
        invPhysModelName,
        invPhysIsFRU }
    STATUS      current
    DESCRIPTION
        "Sent when a physical entity is removed from the
        inventory.

"
    ::= { invNotifyPrefix 2 }


-- ----------------------------------------------------
-- Object model group
-- ----------------------------------------------------

invEntityTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF InvEntityEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The entity table."
    ::= { invEntities 1 }

invEntityEntry OBJECT-TYPE
    SYNTAX      InvEntityEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the entity table.
"
    INDEX   { invEntityIndex }
    ::= { invEntityTable 1 }

InvEntityEntry ::= SEQUENCE {
      invEntityIndex            Unsigned32,
      invEntityName             MgmtNameString,
      invEntityObject           RowPointer,
      invEntityClass            EntityClass }

invEntityIndex    OBJECT-TYPE
    SYNTAX      Unsigned32 (1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An arbitrary index assigned to each entry.
"
    ::= { invEntityEntry 1 }

invEntityName OBJECT-TYPE
    SYNTAX      MgmtNameString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The management name of the object this entry is
        related to.
"
    ::= { invEntityEntry 2 }

invEntityObject OBJECT-TYPE
    SYNTAX      RowPointer
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Pointer to the object related to this entry.
"
    ::= { invEntityEntry 3 }

invEntityClass OBJECT-TYPE
    SYNTAX      EntityClass
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indicates the type of entity.
"
    ::= { invEntityEntry 4 }


-- ----------------------------------------------------
-- Object relation group
-- ----------------------------------------------------

invRelationTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF InvRelationEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Relation table."
    ::= { invRelations 1 }

invRelationEntry OBJECT-TYPE
    SYNTAX      InvRelationEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the relation table.
"
    INDEX   { invRelationIndex }
    ::= { invRelationTable 1 }

InvRelationEntry ::= SEQUENCE {
      invRelationIndex          Unsigned32,
      invRelationEntityIndex1   Unsigned32,
      invRelationEntityName1    MgmtNameString,
      invRelationType           INTEGER,
      invRelationEntityIndex2   Unsigned32,
      invRelationEntityName2    MgmtNameString }

invRelationIndex    OBJECT-TYPE
    SYNTAX      Unsigned32 (1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An arbitrary index assigned to each entry.

"
    ::= { invRelationEntry 1 }

invRelationEntityIndex1    OBJECT-TYPE
    SYNTAX      Unsigned32 (1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Index in to the entity table.
"
    ::= { invRelationEntry 2 }

invRelationEntityName1    OBJECT-TYPE
    SYNTAX      MgmtNameString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Index in to the entity table.
"
    ::= { invRelationEntry 3 }

invRelationType    OBJECT-TYPE
    SYNTAX      INTEGER {
        undefined (0),
        containedIn (1),
        dependsOn (2) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indicates how entity 2 is related to entity 1.

        containedIn - Physical containment. Entity 2 is
        physically contained within entity 1.

        dependsOn - The correct function of entity 2
        depends on the function of entity 1.
"
    ::= { invRelationEntry 4 }

invRelationEntityIndex2    OBJECT-TYPE
    SYNTAX      Unsigned32 (1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Index in to the entity table.
"
    ::= { invRelationEntry 5 }


invRelationEntityName2    OBJECT-TYPE
    SYNTAX      MgmtNameString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Name of the object.
"
    ::= { invRelationEntry 6 }

-- ----------------------------------------------------
-- Insert/remove log group
-- ----------------------------------------------------

invInsRemTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF InvInsRemEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "This table contains one row per insert or
            remove event of any physical entity."
    ::= { invInsRemLog 1 }

invInsRemEntry OBJECT-TYPE
    SYNTAX      InvInsRemEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "Information about a particular insert
            or remove entry.

"
    INDEX   { invInsRemIndex }
    ::= { invInsRemTable 1 }

InvInsRemEntry ::= SEQUENCE {
        invInsRemIndex              Unsigned32,
        invInsRemName               MgmtNameString,
        invInsRemEvent              InsRemEventType,
        invInsRemTimestamp          DateAndTime,
        invInsRemEquipmentType      PhysicalClass,
        invInsRemPhysicalLocation   DisplayString,
        invInsRemClei               DisplayString,
        invInsRemSerialNumber       DisplayString,
        invInsRemPartNumber         DisplayString,
        invInsRemSeqNumber          Counter32 }

invInsRemIndex    OBJECT-TYPE
    SYNTAX      Unsigned32 (1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The index for this entry.

"
    ::= { invInsRemEntry 1 }

invInsRemName OBJECT-TYPE
    SYNTAX      MgmtNameString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The management name of the object this entry
        is related to.

"
    ::= { invInsRemEntry 2 }

invInsRemEvent OBJECT-TYPE
    SYNTAX      InsRemEventType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The type of event.

"
    ::= { invInsRemEntry 3 }

invInsRemTimestamp OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the event occurred.

"
    ::= { invInsRemEntry 4 }

invInsRemEquipmentType OBJECT-TYPE
    SYNTAX      PhysicalClass
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The Part Number of the product.

"
    ::= { invInsRemEntry 5 }

invInsRemPhysicalLocation OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..255))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The physical location of the product.

"
    ::= { invInsRemEntry 6 }

invInsRemClei OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..10))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The Common Language Equipment Identifier
        (CLEI) code for the product.

"
    ::= { invInsRemEntry 7 }

invInsRemSerialNumber   OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..32))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The serial number string for the
        physical entity.

"
    ::= { invInsRemEntry 8 }

invInsRemPartNumber OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The Part Number of the product.

"
    ::= { invInsRemEntry 9 }

invInsRemSeqNumber OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The last sequence number used when
        this event occurred.

"
    ::= { invInsRemEntry 10 }

-- ----------------------------------------------------
-- Object and event groups
-- ----------------------------------------------------

invPhysGroup OBJECT-GROUP
    OBJECTS {
        invPhysIndex,
        invPhysDescr,
        invPhysVendorType,
        invPhysContainedIn,
        invPhysClass,
        invPhysParentRelPos,
        invPhysName,
        invPhysHardwareRev,
        invPhysFirmwareRev,
        invPhysProductDataRev,
        invPhysSerialNum,
        invPhysMfgName,
        invPhysModelName,
        invPhysIsFRU }
    STATUS      deprecated
    DESCRIPTION
        "The physical inventory objects."
    ::= { lumInventoryGroups 1 }

invGeneralGroup OBJECT-GROUP
    OBJECTS {
        invGeneralLastChangeTime,
        invGeneralMibSpecVersion,
        invGeneralMibImplVersion,
        invGeneralTestAndIncr }
    STATUS      deprecated
    DESCRIPTION
        "The physical inventory objects."
    ::= { lumInventoryGroups 2 }

invEventGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        invNotificationPhysAdded,
        invNotificationPhysRemoved }
    STATUS      current
    DESCRIPTION
        "The inventory notifications."
    ::= { lumInventoryGroups 3 }


invGeneralGroupV2 OBJECT-GROUP
    OBJECTS {
        invGeneralLastChangeTime }
    STATUS      deprecated
    DESCRIPTION
        "The physical inventory objects."
    ::= { lumInventoryGroups 4 }

invPhysGroupV2 OBJECT-GROUP
    OBJECTS {
        invPhysIndex,
        invPhysDescr,
        invPhysVendorType,
        invPhysContainedIn,
        invPhysClass,
        invPhysParentRelPos,
        invPhysName,
        invPhysHardwareRev,
        invPhysFirmwareRev,
        invPhysProductDataRev,
        invPhysSerialNum,
        invPhysMfgName,
        invPhysModelName,
        invPhysIsFRU,
        invPhysSoftwareRev }
    STATUS      deprecated
    DESCRIPTION
        "The physical inventory objects V2."
    ::= { lumInventoryGroups 5 }

invPhysGroupV3 OBJECT-GROUP
    OBJECTS {
        invPhysIndex,
        invPhysDescr,
        invPhysVendorType,
        invPhysContainedIn,
        invPhysClass,
        invPhysParentRelPos,
        invPhysName,
        invPhysHardwareRev,
        invPhysFirmwareRev,
        invPhysProductDataRev,
        invPhysSerialNum,
        invPhysMfgName,
        invPhysModelName,
        invPhysIsFRU,
        invPhysSoftwareRev,
        invPhysSoftwareProduct }
    STATUS      deprecated
    DESCRIPTION
        "The physical inventory objects V3."
    ::= { lumInventoryGroups 6 }

invEntityGroup OBJECT-GROUP
    OBJECTS {
      invEntityIndex,
      invEntityName,
      invEntityObject,
      invEntityClass }
    STATUS      current
    DESCRIPTION
        "The entity objects V1."
    ::= { lumInventoryGroups 7 }

invRelationGroup OBJECT-GROUP
    OBJECTS {
      invRelationIndex,
      invRelationEntityIndex1,
      invRelationEntityName1,
      invRelationType,
      invRelationEntityIndex2,
      invRelationEntityName2 }
    STATUS      current
    DESCRIPTION
        "The relation objects V1."
    ::= { lumInventoryGroups 8 }

invGeneralGroupV3 OBJECT-GROUP
    OBJECTS {
        invGeneralLastChangeTime,
        invGeneralConfigLastChangeTime}
    STATUS      deprecated
    DESCRIPTION
        "The physical inventory objects."
    ::= { lumInventoryGroups 9 }

invGeneralGroupV4 OBJECT-GROUP
    OBJECTS {
        invGeneralLastChangeTime,
        invGeneralConfigLastChangeTime,
        invGeneralPhysTableSize,
        invGeneralEntityTableSize,
        invGeneralRelationTableSize}
    STATUS      deprecated
    DESCRIPTION
        "The physical inventory objects v4."
    ::= { lumInventoryGroups 10 }

invPhysGroupV4 OBJECT-GROUP
    OBJECTS {
        invPhysIndex,
        invPhysDescr,
        invPhysContainedIn,
        invPhysClass,
        invPhysParentRelPos,
        invPhysName,
        invPhysHardwareRev,
        invPhysFirmwareRev,
        invPhysProductDataRev,
        invPhysSerialNum,
        invPhysMfgName,
        invPhysModelName,
        invPhysIsFRU,
        invPhysSoftwareRev,
        invPhysSoftwareProduct }
    STATUS      deprecated
    DESCRIPTION
        "The physical inventory objects V4 (release R23.1)."
    ::= { lumInventoryGroups 11 }

invPhysGroupV5 OBJECT-GROUP
    OBJECTS {
        invPhysIndex,
        invPhysDescr,
        invPhysContainedIn,
        invPhysClass,
        invPhysParentRelPos,
        invPhysName,
        invPhysHardwareRev,
        invPhysFirmwareRev,
        invPhysProductDataRev,
        invPhysSerialNum,
        invPhysMfgName,
        invPhysModelName,
        invPhysIsFRU,
        invPhysSoftwareRev,
        invPhysSoftwareProduct,
        invPhysClei,
        invPhysAid }
    STATUS      current
    DESCRIPTION
        "The physical inventory objects V5 (release R28)."
    ::= { lumInventoryGroups 12 }

invInsRemGroup OBJECT-GROUP
    OBJECTS {
        invInsRemIndex,
        invInsRemName,
        invInsRemEvent,
        invInsRemTimestamp,
        invInsRemEquipmentType,
        invInsRemPhysicalLocation,
        invInsRemClei,
        invInsRemSerialNumber,
        invInsRemPartNumber,
        invInsRemSeqNumber }
    STATUS      current
    DESCRIPTION
        "The insert remove events objects V1 (release R28)."
    ::= { lumInventoryGroups 13 }

invGeneralGroupV5 OBJECT-GROUP
    OBJECTS {
        invGeneralLastChangeTime,
        invGeneralConfigLastChangeTime,
        invGeneralPhysTableSize,
        invGeneralEntityTableSize,
        invGeneralRelationTableSize,
        invGeneralInsRemTableSize,
        invGeneralInsRemLastSeqNumber }
    STATUS      current
    DESCRIPTION
        "The physical inventory objects V5 (release R28)."
    ::= { lumInventoryGroups 14 }


-- ----------------------------------------------------
-- Compliance
-- ----------------------------------------------------

lumInventoryBasicComplV1 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the
        inventory MIB."
    MODULE
        MANDATORY-GROUPS {
            invPhysGroup,
            invGeneralGroup,
            invEventGroup }
    ::= { lumInventoryCompl 1 }

lumInventoryBasicComplV2 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the
        inventory MIB v2."
    MODULE
        MANDATORY-GROUPS {
            invGeneralGroupV2,
            invPhysGroup,
            invEventGroup }
    ::= { lumInventoryCompl 2 }

lumInventoryBasicComplV3 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the
        inventory MIB v3."
    MODULE
        MANDATORY-GROUPS {
            invGeneralGroupV2,
            invPhysGroupV2,
            invEventGroup }
    ::= { lumInventoryCompl 3 }

lumInventoryBasicComplV4 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the
        inventory MIB v4."
    MODULE
        MANDATORY-GROUPS {
            invGeneralGroupV2,
            invPhysGroupV3,
            invEventGroup }
    ::= { lumInventoryCompl 4 }

lumInventoryBasicComplV5 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the
        inventory MIB v5."
    MODULE
        MANDATORY-GROUPS {
            invGeneralGroupV2,
            invPhysGroupV3,
            invEventGroup,
            invEntityGroup,
            invRelationGroup }
    ::= { lumInventoryCompl 5 }

lumInventoryBasicComplV6 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the
        inventory MIB v6."
    MODULE
        MANDATORY-GROUPS {
            invGeneralGroupV3,
            invPhysGroupV3,
            invEventGroup,
            invEntityGroup,
            invRelationGroup }
    ::= { lumInventoryCompl 6 }

lumInventoryBasicComplV7 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the
        inventory MIB v7."
    MODULE
        MANDATORY-GROUPS {
            invGeneralGroupV4,
            invPhysGroupV3,
            invEventGroup,
            invEntityGroup,
            invRelationGroup }
    ::= { lumInventoryCompl 7 }

lumInventoryBasicComplV8 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the
        inventory MIB v8."
    MODULE
        MANDATORY-GROUPS {
            invGeneralGroupV4,
            invPhysGroupV4,
            invEventGroup,
            invEntityGroup,
            invRelationGroup }
    ::= { lumInventoryCompl 8 }

lumInventoryBasicComplV9 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the
        inventory MIB v9."
    MODULE
        MANDATORY-GROUPS {
            invGeneralGroupV4,
            invPhysGroupV5,
            invEventGroup,
            invEntityGroup,
            invRelationGroup }
    ::= { lumInventoryCompl 9 }

lumInventoryBasicComplV10 MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
        "Basic implementation requirements for the
        inventory MIB v10. (R28.0)"
    MODULE
        MANDATORY-GROUPS {
            invGeneralGroupV5,
            invPhysGroupV5,
            invEventGroup,
            invEntityGroup,
            invRelationGroup,
            invInsRemGroup }
    ::= { lumInventoryCompl 10 }

-- ----------------------------------------------------
-- Minimal object and event groups
-- ----------------------------------------------------

inventoryGeneralMinimalGroupV1 OBJECT-GROUP
    OBJECTS {
        invGeneralLastChangeTime,
        invGeneralConfigLastChangeTime,
        invGeneralPhysTableSize,
        invGeneralEntityTableSize,
        invGeneralRelationTableSize }
    STATUS      current
    DESCRIPTION
        "The minimal general inventory objects."
    ::= { lumInventoryMinimalGroups 1 }

-- ----------------------------------------------------
-- Minimal Compliance
-- ----------------------------------------------------

lumInventoryMinimalComplV1 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Minimal implementation requirements for the inventory MIB v1."
    MODULE
        MANDATORY-GROUPS {
            inventoryGeneralMinimalGroupV1,
            invPhysGroupV3,
            invEntityGroup,
            invRelationGroup }
    ::= { lumInventoryMinimalCompl 1 }

lumInventoryMinimalComplV2 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Minimal implementation requirements for the inventory MIB v1."
    MODULE
        MANDATORY-GROUPS {
            inventoryGeneralMinimalGroupV1,
            invPhysGroupV4,
            invEntityGroup,
            invRelationGroup }
    ::= { lumInventoryMinimalCompl 2 }

lumInventoryMinimalComplV3 MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
        "Minimal implementation requirements for the inventory MIB v2."
    MODULE
        MANDATORY-GROUPS {
            inventoryGeneralMinimalGroupV1,
            invPhysGroupV5,
            invEntityGroup,
            invRelationGroup }
    ::= { lumInventoryMinimalCompl 3 }

END