1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
|
-- ICT MIB file for ICT Modular Power System.
--
-- Date Version
-- =============================
-- 1/5/18 v1.01
--
ICT-MODULAR-POWER-SYSTEM-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, IpAddress FROM RFC1155-SMI
DisplayString FROM RFC1213-MIB
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215;
ictPower OBJECT IDENTIFIER ::= { enterprises 39145 }
powerSystem OBJECT IDENTIFIER ::= { ictPower 13 }
deviceModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Model Number"
::= { powerSystem 1 }
deviceName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Device Name"
::= { powerSystem 2 }
deviceHardware OBJECT-TYPE
SYNTAX INTEGER (0..127)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Hardware Version"
::= { powerSystem 3 }
deviceFirmware OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Firmware Version"
::= { powerSystem 4 }
deviceMacAddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "MAC Address"
::= { powerSystem 5 }
inputVoltage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Input Voltage (VAC)"
::= { powerSystem 6 }
outputVoltage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Output Voltage (VDC)"
::= { powerSystem 7 }
outputCurrent OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Total System Current (Amps)"
::= { powerSystem 8 }
outputEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Output Enable Status (a value of '1' indicates Output is Enabled, and a value of '2' indicates Output is Disabled. Output cannot be disabled during an AC Failure)"
::= { powerSystem 9 }
moduleTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Module Table"
::= { powerSystem 10 }
moduleEntry OBJECT-TYPE
SYNTAX ModuleEntry
ACCESS not-accessible
STATUS mandatory
INDEX { moduleNumber }
::= { moduleTable 1 }
ModuleEntry ::=
SEQUENCE {
moduleNumber INTEGER,
moduleStatus INTEGER,
moduleType INTEGER,
moduleVoltage DisplayString,
moduleCurrentA DisplayString,
moduleCurrentB DisplayString,
moduleCurrentC DisplayString,
moduleCurrentD DisplayString,
moduleControlA INTEGER,
moduleControlB INTEGER,
moduleControlC INTEGER,
moduleControlD INTEGER
}
moduleNumber OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Module Number"
::= { moduleEntry 1 }
moduleStatus OBJECT-TYPE
SYNTAX INTEGER { notInstalled(1), ok(2), alarm(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Module Status"
::= { moduleEntry 2 }
moduleType OBJECT-TYPE
SYNTAX INTEGER { notInstalled(1), power(2), battery(3), distribution(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Module Type ('1' indicates Module is NOT INSTALLED,'2' indicates POWER Module,'3' indicates BATTERY Module, and '4' indicates DISTRIBUTION Module)"
::= { moduleEntry 3 }
moduleVoltage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Module Voltage (VDC)"
::= { moduleEntry 4 }
moduleCurrentA OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Channel 1 Current (Amps)"
::= { moduleEntry 5 }
moduleCurrentB OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Channel 2 Current (Amps)"
::= { moduleEntry 6 }
moduleCurrentC OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Channel 3 Current (Amps)"
::= { moduleEntry 7 }
moduleCurrentD OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Channel 4 Current (Amps)"
::= { moduleEntry 8 }
moduleControlA OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Channel 1 Control (a value of '1' indicates Channel is Enabled, and a value of '2' indicates Channel is Disabled)"
::= { moduleEntry 9 }
moduleControlB OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Channel 2 Control (a value of '1' indicates Channel is Enabled, and a value of '2' indicates Channel is Disabled)"
::= { moduleEntry 10 }
moduleControlC OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Channel 3 Control (a value of '1' indicates Channel is Enabled, and a value of '2' indicates Channel is Disabled)"
::= { moduleEntry 11 }
moduleControlD OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Channel 4 Control (a value of '1' indicates Channel is Enabled, and a value of '2' indicates Channel is Disabled)"
::= { moduleEntry 12 }
alarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Alarm Input Table"
::= { powerSystem 11 }
alarmEntry OBJECT-TYPE
SYNTAX AlarmEntry
ACCESS not-accessible
STATUS mandatory
INDEX { alarmNumber }
::= { alarmTable 1 }
AlarmEntry ::=
SEQUENCE {
alarmNumber INTEGER,
alarmName DisplayString,
alarmStatus INTEGER
}
alarmNumber OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Alarm Input Number"
::= { alarmEntry 1 }
alarmName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Alarm Input Name"
::= { alarmEntry 2 }
alarmStatus OBJECT-TYPE
SYNTAX INTEGER { inactive(1), ready(2), alarm(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Alarm Input Status ('1' indicates Alarm is INACTIVE,'2' indicates Alarm is READY, and '3' indicates Alarm is in an ALARM condition)"
::= { alarmEntry 3 }
--
-- Trap definitions:
--
moduleAlarmTrap TRAP-TYPE
ENTERPRISE powerSystem
VARIABLES { moduleNumber }
DESCRIPTION "Trap generated when a Module Alarm is triggered"
::= 101
alarmInputTrap TRAP-TYPE
ENTERPRISE powerSystem
VARIABLES { alarmNumber }
DESCRIPTION "Trap generated when an Alarm Input is activated"
::= 102
acFailAlarmTrap TRAP-TYPE
ENTERPRISE powerSystem
DESCRIPTION "Trap generated when the AC Failure Alarm is triggered"
::= 103
sysCurrentLimitTrap TRAP-TYPE
ENTERPRISE powerSystem
DESCRIPTION "Trap generated when the System Current Limit Alarm is triggered"
::= 104
moduleAlarmClear TRAP-TYPE
ENTERPRISE powerSystem
VARIABLES { moduleNumber }
DESCRIPTION "Trap generated when a Module Alarm is cleared"
::= 111
alarmInputClear TRAP-TYPE
ENTERPRISE powerSystem
VARIABLES { alarmNumber }
DESCRIPTION "Trap generated when an Alarm Input is cleared"
::= 112
acFailAlarmClear TRAP-TYPE
ENTERPRISE powerSystem
DESCRIPTION "Trap generated when the AC Failure Alarm is cleared"
::= 113
sysCurrentLimitClear TRAP-TYPE
ENTERPRISE powerSystem
DESCRIPTION "Trap generated when the System Current Limit Alarm is cleared"
::= 114
batteryTestStart TRAP-TYPE
ENTERPRISE powerSystem
DESCRIPTION "Trap generated when a Battery Discharge Test is started"
::= 121
batteryTestComplete TRAP-TYPE
ENTERPRISE powerSystem
DESCRIPTION "Trap generated when a Battery Discharge Test completes successfully"
::= 122
batteryTestFail TRAP-TYPE
ENTERPRISE powerSystem
DESCRIPTION "Trap generated when a Battery Discharge Test fails"
::= 123
batteryEqualiseStart TRAP-TYPE
ENTERPRISE powerSystem
DESCRIPTION "Trap generated when a Battery Equalise Charge is started"
::= 124
batteryEqualiseComplete TRAP-TYPE
ENTERPRISE powerSystem
DESCRIPTION "Trap generated when a Battery Equalise Charge completes"
::= 125
END
|