1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
|
--==================================================================
-- Copyright (C) 2006 by HUAWEI TECHNOLOGIES. All rights reserved.
--
-- Description: HUAWEI Transmission Alarm Damping MIB
-- Reference:
-- Version: V1.0
-- History:
-- <author>, <date>, <contents>
-- Jiangwei 2006-6-28
-- ==================================================================
-- ==================================================================
--
-- Variables and types be imported
--
-- ==================================================================
HUAWEI-TAD-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, OBJECT-IDENTITY
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DisplayString, DateAndTime
FROM SNMPv2-TC
hwDatacomm
FROM HUAWEI-MIB
ifIndex,InterfaceIndex
FROM IF-MIB ;
hwTAD MODULE-IDENTITY
LAST-UPDATED "200606281600Z"
ORGANIZATION
"Huawei Technologies co.,Ltd."
CONTACT-INFO
"VRP Platform Team Huawei Technologies co.,Ltd.
Huawei Bld.,NO.3 Xinxi Rd.,
Shang-Di Information Industry Base,
Hai-Dian District Beijing P.R. China
http://www.huawei.com
Zip:100085"
DESCRIPTION
"The Custom damping MIB module is defined to manage the configuration under system or interface view."
::= { hwDatacomm 128 }
HWEnableValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A simple status value for the object."
SYNTAX INTEGER { enable(1), disable(2) }
-- ==================================================================
--
-- ======================= Definitions begin =========================
--
-- ==================================================================
hwTADObjects OBJECT IDENTIFIER ::= { hwTAD 1 }
-- ======================= interface table =========================
hwTADInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwTADInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Transmission alarm damping interface configuration table."
::= { hwTADObjects 1 }
hwTADInterfaceEntry OBJECT-TYPE
SYNTAX HwTADInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The entry of a SDH or SONET interface with damping function enabled."
INDEX { hwTADInterfaceIndex }
::= { hwTADInterfaceTable 1}
HwTADInterfaceEntry ::=
SEQUENCE {
hwTADInterfaceIndex InterfaceIndex ,
hwTADFilterEnable HWEnableValue ,
hwTADFilterExpireTime Integer32 ,
hwTADDampingEnable HWEnableValue ,
hwTADSuppress Integer32 ,
hwTADCeiling Integer32 ,
hwTADReuse Integer32 ,
hwTADDecayOk Integer32 ,
hwTADDecayNg Integer32 ,
hwTADResetStatistics INTEGER ,
hwTADResetTime DateAndTime ,
hwTADB3tcaThreshold Integer32 ,
hwTADSdbereThreshold Integer32 ,
hwTADSfbereThreshold Integer32
}
hwTADInterfaceIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Index number of the interface."
::= { hwTADInterfaceEntry 1 }
hwTADFilterEnable OBJECT-TYPE
SYNTAX HWEnableValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Whether filter function is enabled."
DEFVAL { disable }
::= { hwTADInterfaceEntry 2 }
hwTADFilterExpireTime OBJECT-TYPE
SYNTAX Integer32(20..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "How long the alarm will be postponed to process. Unit: millisecond."
DEFVAL { 50 }
::= { hwTADInterfaceEntry 3 }
hwTADDampingEnable OBJECT-TYPE
SYNTAX HWEnableValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Whether damping function is enabled."
DEFVAL { disable }
::= { hwTADInterfaceEntry 4 }
hwTADSuppress OBJECT-TYPE
SYNTAX Integer32(2..19999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The suppressing value. When figure-of-merit of alarm exceeds this value,
this alarm will be damped."
DEFVAL { 2000 }
::= { hwTADInterfaceEntry 5 }
hwTADCeiling OBJECT-TYPE
SYNTAX Integer32(1001..20000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The ceiling value. Figure-of-merit can't exceed this value. The ceiling
value must be larger than suppressing value."
DEFVAL { 6000 }
::= { hwTADInterfaceEntry 6 }
hwTADReuse OBJECT-TYPE
SYNTAX Integer32(1..19998)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The reusing value. When figure-of-merit becomes lower than this value.
The alarm will be reused (exit from suppressing status). The reusing value must be
less than suppressing value."
DEFVAL { 750 }
::= { hwTADInterfaceEntry 7 }
hwTADDecayOk OBJECT-TYPE
SYNTAX Integer32(500..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The half decay time when alarm status is down. Unit: millisecond."
DEFVAL { 1000 }
::= { hwTADInterfaceEntry 8 }
hwTADDecayNg OBJECT-TYPE
SYNTAX Integer32(500..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The half decay time when alarm status is up. Unit: millisecond."
DEFVAL { 1000 }
::= { hwTADInterfaceEntry 9 }
hwTADResetStatistics OBJECT-TYPE
SYNTAX INTEGER{
reset(1),
unreset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Whether to reset alarm statistics. 1 means resetting statistics once."
DEFVAL { 2 }
::= { hwTADInterfaceEntry 10 }
hwTADResetTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Last reset time."
::= { hwTADInterfaceEntry 11 }
hwTADB3tcaThreshold OBJECT-TYPE
SYNTAX Integer32(3..9)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "B3tca threshold in form of 10e-n."
DEFVAL { 6 }
::= { hwTADInterfaceEntry 12 }
hwTADSdbereThreshold OBJECT-TYPE
SYNTAX Integer32(3..9)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Sdbere threshold in form of 10e-n."
DEFVAL { 6 }
::= { hwTADInterfaceEntry 13 }
hwTADSfbereThreshold OBJECT-TYPE
SYNTAX Integer32(3..9)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Sfbere threshold in form of 10e-n."
DEFVAL { 3 }
::= { hwTADInterfaceEntry 14 }
-- ======================= alarm table =========================
hwTADAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwTADAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Transmission alarm damping alarm configuration table."
::= { hwTADObjects 2 }
hwTADAlarmEntry OBJECT-TYPE
SYNTAX HwTADAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The entry of an alarm."
INDEX { hwTADAlarmIfIndex, hwTADAlarmType }
::= { hwTADAlarmTable 1}
HwTADAlarmEntry ::=
SEQUENCE {
hwTADAlarmIfIndex InterfaceIndex ,
hwTADAlarmType INTEGER ,
hwTADAlarmIfDown HWEnableValue ,
hwTADAlarmLog HWEnableValue ,
hwTADAlarmStatus INTEGER ,
hwTADAlarmInFilter INTEGER ,
hwTADAlarmFigure DisplayString ,
hwTADAlarmInSuppress INTEGER ,
hwTADAlarmFlappingCount Counter32 ,
hwTADAlarmSuppressCount Counter32
}
hwTADAlarmIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Index number of the interface."
::= { hwTADAlarmEntry 1 }
hwTADAlarmType OBJECT-TYPE
SYNTAX INTEGER{
auais(1),
b3tca(2),
lais(3),
lof(4),
lom(5),
lop(6),
los(7),
lrdi(8),
lrei(9),
oof(10),
pais(11),
prdi(12),
prei(13),
pplm(14),
rdool(15),
rrool(16),
sdbere(17),
sfbere(18),
trool(19),
puneq(20),
lcd(21),
wlnk(22)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Index number of the alarm. The range is from 1 to 22, corresponding to:
auais, batca, lais, lof, lom, lop, los, lrdi, lrei, oof, pais, prdi, prei, pplm, rdool,
rrool, sdbere, sfbere, trool, puneq, lcd, wlnk."
::= { hwTADAlarmEntry 2 }
hwTADAlarmIfDown OBJECT-TYPE
SYNTAX HWEnableValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Whether this alarm leads to interface down. In default lais, lof and los
are enabled to lead interface down."
::= { hwTADAlarmEntry 3 }
hwTADAlarmLog OBJECT-TYPE
SYNTAX HWEnableValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Whether this alarm will be logged. In default all alarm types won't be logged."
DEFVAL { disable }
::= { hwTADAlarmEntry 4 }
hwTADAlarmStatus OBJECT-TYPE
SYNTAX INTEGER{
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The status of the alarm. 1 means alarm is up, 2 means alarm is down."
::= { hwTADAlarmEntry 5 }
hwTADAlarmInFilter OBJECT-TYPE
SYNTAX INTEGER {
in(1),
out(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Whether this alarm is in filtering status. 1 means alarm is in filtering status,
2 means alarm isn't in filtering status."
::= { hwTADAlarmEntry 6 }
hwTADAlarmFigure OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This figure is used to evaluate the stability of the alarm. Large
value means un-stability."
::= { hwTADAlarmEntry 7 }
hwTADAlarmInSuppress OBJECT-TYPE
SYNTAX INTEGER{
suppressed(1),
unsuppressed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Whether this alarm is in suppressing status. 1 means alarm is
in suppressing status, 2 means alarm isn't in suppressing status."
::= { hwTADAlarmEntry 8 }
hwTADAlarmFlappingCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "How many times alarm's status changed."
::= { hwTADAlarmEntry 9 }
hwTADAlarmSuppressCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "How many times alarm is suppressed."
::= { hwTADAlarmEntry 10 }
-- -------------------------------------------------------------
-- HUAWEI-CUSTOM-DAMPING-MIB MIB - Conformance Information
-- -------------------------------------------------------------
hwTADConformance OBJECT IDENTIFIER ::= { hwTAD 2 }
hwTADGroups OBJECT IDENTIFIER ::= { hwTADConformance 1 }
-- -------------------------------------------------------------
-- Units of conformance
-- -------------------------------------------------------------
hwTADInterfaceGroup OBJECT-GROUP
OBJECTS {
hwTADFilterEnable ,
hwTADFilterExpireTime ,
hwTADDampingEnable ,
hwTADSuppress ,
hwTADCeiling ,
hwTADReuse ,
hwTADDecayOk ,
hwTADDecayNg ,
hwTADResetStatistics ,
hwTADResetTime ,
hwTADB3tcaThreshold ,
hwTADSdbereThreshold ,
hwTADSfbereThreshold
}
STATUS current
DESCRIPTION
"A collection of objects providing device level control
and status information for the interface."
::= { hwTADGroups 1 }
hwTADAlarmGroup OBJECT-GROUP
OBJECTS {
hwTADAlarmIfDown ,
hwTADAlarmLog ,
hwTADAlarmStatus ,
hwTADAlarmInFilter ,
hwTADAlarmFigure ,
hwTADAlarmInSuppress ,
hwTADAlarmFlappingCount ,
hwTADAlarmSuppressCount
}
STATUS current
DESCRIPTION
"A collection of objects providing device level control
and status information for the alarm."
::= { hwTADGroups 2 }
END
|