1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
|
-- =================================================================
-- Copyright (C) 2007 by HUAWEI TECHNOLOGIES. All rights reserved.
--
-- Description: HUAWEI Inner Link MIB File for inner links between
-- frames
-- Reference:
-- Version: V1.00
-- History:
--
-- V1.00 2007-10-24, Create
-- =================================================================
HUAWEI-INNER-LINK-MIB DEFINITIONS ::= BEGIN
IMPORTS
hwDatacomm
FROM HUAWEI-MIB
PhysicalIndex
FROM ENTITY-MIB
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
FROM SNMPv2-CONF
Unsigned32, BITS, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DisplayString
FROM SNMPv2-TC;
hwInnerLinkMIB MODULE-IDENTITY
LAST-UPDATED "200710241430Z" -- Oct. 24, 2007 at 14:30 GMT
ORGANIZATION
"Huawei Technologies co.,Ltd."
CONTACT-INFO
" R&D BeiJing, Huawei Technologies co.,Ltd.
Huawei Bld.,NO.3 Xinxi Rd.,
Shang-Di Information Industry Base,
Hai-Dian District Beijing P.R. China
Zip:100085
Http://www.huawei.com
E-mail:support@huawei.com "
DESCRIPTION
"The private mib file includes the general
information of inner links between frames
in cluster system."
::= { hwDatacomm 158 }
--
-- Node definitions
--
hwInnerLinkMIBObjects OBJECT IDENTIFIER ::= { hwInnerLinkMIB 1 }
hwInnerLinkMIBObjPrefix OBJECT IDENTIFIER ::= { hwInnerLinkMIBObjects 1 }
hwInnerLinkLeftPortPhysicalIndex OBJECT-TYPE
SYNTAX PhysicalIndex
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"To describe physical entity index of left port of
the physical link which is part of the corresponding
inner logical link."
::= { hwInnerLinkMIBObjPrefix 1 }
hwInnerLinkLeftPortPhysicalName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"To describe physical entity name of left port of
the physical link which is part of the corresponding
inner logical link."
::= { hwInnerLinkMIBObjPrefix 2 }
hwInnerLinkRightPortPhysicalIndex OBJECT-TYPE
SYNTAX PhysicalIndex
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"To describe physical entity index of right port of
the physical link which is part of the corresponding
inner logical link."
::= { hwInnerLinkMIBObjPrefix 3 }
hwInnerLinkRightPortPhysicalName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"To describe physical entity name of right port of
the physical link which is part of the corresponding
inner logical link."
::= { hwInnerLinkMIBObjPrefix 4 }
hwInnerLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwInnerLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per inner link entity.
Each inner link is composed of all physical links
of the same kind between two frames.
It describes the status of the inner link between
frames in NE5000E Cluster system."
::= { hwInnerLinkMIBObjects 2 }
hwInnerLinkEntry OBJECT-TYPE
SYNTAX HwInnerLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular inner link entity.
Each entry provides left and right vitural port and status
of the link to NMS to manage the links."
INDEX { hwInnerLinkIndex }
::= { hwInnerLinkTable 1 }
HwInnerLinkEntry ::=
SEQUENCE {
hwInnerLinkIndex
Unsigned32,
hwInnerLinkLeftFrameType
INTEGER,
hwInnerLinkLeftFrameId
Unsigned32,
hwInnerLinkLeftPortId
Unsigned32,
hwInnerLinkRightFrameType
INTEGER,
hwInnerLinkRightFrameId
Unsigned32,
hwInnerLinkRightPortId
Unsigned32,
hwInnerLinkType
INTEGER,
hwInnerLinkAdminState
INTEGER,
hwInnerLinkOperState
INTEGER,
hwInnerLinkAlarmLight
BITS
}
hwInnerLinkIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index for this entry.It comprises of left frame
ID, right frame ID and type of the logical link."
::= { hwInnerLinkEntry 1 }
hwInnerLinkLeftFrameType OBJECT-TYPE
SYNTAX INTEGER{
unknown(1),
centralChassis (2),
lineChassis (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frame type of the link's left point. A value of centralChassis
means the central frame in the system which can manage the system.
A value of lineChassis means a frame managed by the central frame."
::= { hwInnerLinkEntry 2 }
hwInnerLinkLeftFrameId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frame ID of the link's left point."
::= { hwInnerLinkEntry 3 }
hwInnerLinkLeftPortId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port ID of the link's left virtual port."
::= { hwInnerLinkEntry 4 }
hwInnerLinkRightFrameType OBJECT-TYPE
SYNTAX INTEGER{
unknown(1),
centralChassis (2),
lineChassis (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frame type of the link's right point."
::= { hwInnerLinkEntry 5 }
hwInnerLinkRightFrameId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frame ID of the link's right point."
::= { hwInnerLinkEntry 6 }
hwInnerLinkRightPortId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port ID of the link's right virtual port."
::= { hwInnerLinkEntry 7 }
hwInnerLinkType OBJECT-TYPE
SYNTAX INTEGER{
unknown(1),
controlChannel(2),
monitorChannel(3),
forwardChannel(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inner link type between the frames. A value of controlChannel
means a kind of logical link through which control messages're
transferred. A value of monitorChannel means a kind of logical
control link which only exists between the central chassises.
A value of forwardChannel mean a kind of logical link which is
used for data forwarding."
::= { hwInnerLinkEntry 8 }
hwInnerLinkAdminState OBJECT-TYPE
SYNTAX INTEGER{
notSupported(1),
locked(2),
shuttingDown(3),
unlocked(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative state for this object, and it is possible
to set the state when needed. A value of locked means the resource
is administratively prohibited from use. A value of shuttingDown
means that usage is administratively limited to current instances
of use. A value of unlocked means the resource is not administratively
prohibited from use."
::= { hwInnerLinkEntry 9 }
hwInnerLinkOperState OBJECT-TYPE
SYNTAX INTEGER{
unknown(1),
mostPhyChannelUp(2),
partPhyChannelUp(3),
mostPhyChannelDown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational state for this object. A value of mostPhyChannelUp means
most of the physical links consisting of the logical link are working well.
It's possible that none of the physical links is wrong. A value of
partPhyChannelUp means several physical links of the logical link are broken
down. A value of mostPhyChannelDown means most of the physical links of the
logical link are down. It's possible that none of the physical links is ok. "
::= { hwInnerLinkEntry 10 }
hwInnerLinkAlarmLight OBJECT-TYPE
SYNTAX BITS{
notSupported(0),
underRepair(1),
critical(2),
major(3),
minor(4),
alarmOutstanding(5),
warning(6),
indeterminate(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm status for this entity. It is decided by
the alarm status of the physical links which compose
the logical link.
When no bits of this attribute are set, then none of the
status conditions described below are present. When the
value of under repair is set, the resource is currently
being repaired.
When the value of critical is set, one or more critical
alarms are active against the resource. When the value of
major is set, one or more major alarms are active against
the resource. When the value of minor is set, one or more
minor alarms are active against the resource. When the
value of warning is set, one or more warning alarms are
active against the resource. When the value of
indeterminate is set, one or more alarms of indeterminate
severity are active against the resource.
When the value of alarm outstanding is set, one or more
alarms is active against the resource. The fault may or may
not be disabling."
::= { hwInnerLinkEntry 11 }
hwInnerLinkTraps OBJECT IDENTIFIER ::= { hwInnerLinkMIB 2 }
hwInnerLinkTrapsPrefix OBJECT IDENTIFIER ::= { hwInnerLinkTraps 1 }
hwInnerLinkOnePhysicalLinkUp NOTIFICATION-TYPE
OBJECTS { hwInnerLinkLeftPortPhysicalIndex, hwInnerLinkLeftPortPhysicalName,
hwInnerLinkRightPortPhysicalIndex, hwInnerLinkRightPortPhysicalName }
STATUS current
DESCRIPTION
"One physical link of the corrresponding inner logical link is available."
::= { hwInnerLinkTrapsPrefix 1 }
hwInnerLinkOnePhysicalLinkDown NOTIFICATION-TYPE
OBJECTS { hwInnerLinkLeftPortPhysicalIndex, hwInnerLinkLeftPortPhysicalName,
hwInnerLinkRightPortPhysicalIndex, hwInnerLinkRightPortPhysicalName }
STATUS current
DESCRIPTION
"One physical link of the corrresponding inner logical link is unavailable."
::= { hwInnerLinkTrapsPrefix 2 }
-- Conformance and Compliance
--
hwInnerLinkConformance OBJECT IDENTIFIER ::= { hwInnerLinkMIB 3 }
hwInnerLinkCompliances OBJECT IDENTIFIER ::= { hwInnerLinkConformance 1 }
-- this module
hwInnerLinkCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for systems supporting
the HUAWEI Inner Link MIB."
MODULE -- this module
MANDATORY-GROUPS { hwInnerLinkGroup }
OBJECT hwInnerLinkAdminState
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { hwInnerLinkCompliances 1 }
hwInnerLinkGroups OBJECT IDENTIFIER ::= { hwInnerLinkConformance 2 }
hwInnerLinkGroup OBJECT-GROUP
OBJECTS { hwInnerLinkLeftPortPhysicalIndex, hwInnerLinkLeftPortPhysicalName,
hwInnerLinkRightPortPhysicalIndex, hwInnerLinkRightPortPhysicalName,
hwInnerLinkLeftFrameType, hwInnerLinkLeftFrameId,
hwInnerLinkLeftPortId, hwInnerLinkRightFrameType, hwInnerLinkRightFrameId,
hwInnerLinkRightPortId, hwInnerLinkType, hwInnerLinkAdminState,
hwInnerLinkOperState, hwInnerLinkAlarmLight
}
STATUS current
DESCRIPTION
"HUAWEI Inner Link group."
::= { hwInnerLinkGroups 1 }
hwInnerLinkNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { hwInnerLinkOnePhysicalLinkUp, hwInnerLinkOnePhysicalLinkDown }
STATUS current
DESCRIPTION
"Inner Link Notification group."
::= { hwInnerLinkGroups 2 }
END
--
-- HUAWEI-INNER-LINK-MIB.mib
--
|