-- Copyright (C) 2017 by HUAWEI TECHNOLOGIES. All rights reserved
--
-- Description:HUAWEI ERRORDOWN MIB
-- Reference:
-- Version: V2.01
-- History:
-- V1.00 W55319, 2011-08-08, publish
-- ===========================================================
HUAWEI-ERRORDOWN-MIB DEFINITIONS ::= BEGIN
IMPORTS
hwDatacomm
FROM HUAWEI-MIB
EnabledStatus
FROM P-BRIDGE-MIB
ifIndex, ifName
FROM IF-MIB
DisplayString, RowStatus
FROM SNMPv2-TC
Integer32, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF;
--
-- Module Identifier
--
hwErrordownMIB MODULE-IDENTITY
LAST-UPDATED "201108081000Z" -- Aug 8, 2011 at 10:00 GMT
ORGANIZATION
"Huawei Technologies Co.,Ltd."
CONTACT-INFO
"Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: support@huawei.com
"
DESCRIPTION
"The HUAWEI-ERRORDOWN-MIB contains objects to
Manage configuration and Monitor running state
for ERROR-DOWN feature."
REVISION "201108081000Z" -- Aug 8, 2011 at 10:00 GMT
DESCRIPTION
"The initial revision of this MIB module."
::= { hwDatacomm 257 }
--
-- Objects Identifier
--
hwErrordownObjects OBJECT IDENTIFIER ::= { hwErrordownMIB 1 }
hwErrordownNotifications OBJECT IDENTIFIER ::= { hwErrordownMIB 2 }
hwErrordownConformance OBJECT IDENTIFIER ::= { hwErrordownMIB 3 }
--
-- Node definitions
--
hwErrordownCause OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The cause of error-down."
::= { hwErrordownObjects 1 }
hwErrordownRecoverType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The type of error-down recovery."
::= { hwErrordownObjects 2 }
--
-- Notification Identifier
--
hwErrordown NOTIFICATION-TYPE
OBJECTS { ifName, hwErrordownCause }
STATUS current
DESCRIPTION
"The event is reported when error-down occur."
::= { hwErrordownNotifications 1 }
hwErrordownRecovery NOTIFICATION-TYPE
OBJECTS { ifName, hwErrordownCause, hwErrordownRecoverType }
STATUS current
DESCRIPTION
"The event is reported when error-down recover."
::= { hwErrordownNotifications 2 }
--
-- Conformance Identifier
--
hwErrordownCompliances OBJECT IDENTIFIER ::= { hwErrordownConformance 1 }
hwErrordowFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"This is the Error-down compliance."
MODULE -- this module
MANDATORY-GROUPS { hwErrordownObjectGroup, hwErrordownNotificationGroup }
::= { hwErrordownCompliances 1 }
hwErrordownGroups OBJECT IDENTIFIER ::= { hwErrordownConformance 2 }
hwErrordownObjectGroup OBJECT-GROUP
OBJECTS { hwErrordownCause, hwErrordownRecoverType }
STATUS current
DESCRIPTION
"This is the Error-down object group."
::= { hwErrordownGroups 1 }
hwErrordownNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { hwErrordown, hwErrordownRecovery }
STATUS current
DESCRIPTION
"This is the Error-down notification group."
::= { hwErrordownGroups 2 }
END
|