1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
|
HP-SYSTEM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Gauge32, IpAddress,
NOTIFICATION-TYPE, Unsigned32,
Integer32 FROM SNMPv2-SMI
TEXTUAL-CONVENTION, TruthValue,
DisplayString FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP FROM SNMPv2-CONF
hpProcurveCommon FROM HP-BASE-MIB;
hpProcurveSystem MODULE-IDENTITY
LAST-UPDATED "200502011455Z"
ORGANIZATION "Hewlett Packard Company,
ProCurve Networking Business"
CONTACT-INFO "Hewlett Packard Company
8000 Foothills Blvd.
Roseville, CA 95747"
DESCRIPTION "This MIB module describes objects for basic
management of devices in the HP Procurve
product line."
REVISION "200502011455Z" -- February 1, 2005
DESCRIPTION "Modified to reflect new OID hierarchy for
HP J8162A XL Access Controller Module."
::= { hpProcurveCommon 1 }
hpProcurveSysMib OBJECT IDENTIFIER ::= { hpProcurveSystem 1 }
hpSystemMIBObjects OBJECT IDENTIFIER ::= { hpProcurveSystem 2 }
hpConfig OBJECT IDENTIFIER ::= { hpSystemMIBObjects 1 }
hpStatus OBJECT IDENTIFIER ::= { hpSystemMIBObjects 2 }
hpNotificationsConfig OBJECT IDENTIFIER ::= { hpSystemMIBObjects 3 }
-- System objects
hpProductDescription OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Textual Description of the HW product"
::= { hpProcurveSysMib 1 }
hpProductHWVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "HW version of the product"
::= { hpProcurveSysMib 2 }
hpProductSWVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SW version of the product"
::= { hpProcurveSysMib 3 }
hpProductSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial Number of the product"
::= { hpProcurveSysMib 4 }
hpProductLastChange OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Date and time of last configuration change"
::= { hpProcurveSysMib 5 }
-- Environmental
hpCpuTemperature OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current temperature in degrees centigrade
of the CPU."
::= { hpProcurveSysMib 6 }
hpPowerSupplyTemperature OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Current temperature in degrees centigrade
of the power supply."
::= { hpProcurveSysMib 7 }
hpChassisTemperature OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current temperature in degrees centigrade
of the mother board. Note: this is not the
ambient temperature of the box."
::= { hpProcurveSysMib 8 }
hpFanStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of operational status of all internal
cooling fans."
::= { hpProcurveSysMib 9 }
hpFanStatusEntry OBJECT-TYPE
SYNTAX HpFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry in table of all internal cooling fans."
INDEX { hpFanNumber }
::= { hpFanStatusTable 1 }
HpFanStatusEntry ::=
SEQUENCE {
hpFanNumber INTEGER,
hpFanOperational INTEGER,
hpFanSpeed Integer32
}
hpFanNumber OBJECT-TYPE
SYNTAX INTEGER { cpu(1),power(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identifier of cooling fan, numbered to represent what
hardware the fan is supposed to be cooling."
::= { hpFanStatusEntry 1 }
hpFanOperational OBJECT-TYPE
SYNTAX INTEGER { true(1),false(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Operational status of a cooling fan."
::= { hpFanStatusEntry 2 }
hpFanSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Speed of the fan in RPM."
::= { hpFanStatusEntry 3 }
-- hpConfig group
-- Additional information relating to the configuration of the HP ProCurve Networking
-- Business Device
hpName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A textual string containing information about the
device. For instance, this string reflects the setting of
the HP J8162A XL Access Controller Module Name available on the Administrative
Web based User Interface. If no HP J8162A XL Access Controller Module name
is entered, this object contains a zero-length string."
::= { hpConfig 2 }
hpSystemID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique identifier for this device, as used by
this system, or a master controlling system. For instance, an
HP J8162A XL Access Controller Module would report the systemID used by the
Access Control Server 740wl to uniquely identify this device."
::= { hpConfig 3 }
hpState OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
up(2), -- ready to pass packets
down(3),
primary(4), -- for Failover operation
secondary(5) -- for Failover operation
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the device. A HP ProCurve Networking Business
device can be configured for standalone operation,
Failover (ie with a redundant peer), or for Distribution
of configuration from a controlling central system to
remote entities.
unknown(1) - system Configuration status unknown
up(2) - a standalone system is operational.
down(3) - a system is not operational.
primary(4) - system is running as the primary in
a Failover peer configuration.
secondary(5) - system is running as the backup in
a Failover peer configuration."
::= { hpConfig 4 }
hpDistributionType OBJECT-TYPE
-- NOT CURRENTLY SUPPORTED - will report dummy values
SYNTAX INTEGER {
unknown(1),
rightsPush(2) -- push central rights to remote systems.
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The most recent distribution event type on a device.
This object will change dynamically based on
the most recently triggered distribution event.
unknown(1) - the distribution event type
none(2) - no distribution event has occurred
rightsPush(3) - the central Access Control Server 740wl
has triggered a rights push event to remote Access Control Server
740wls."
::= { hpConfig 5 }
hpDistributionStatus OBJECT-TYPE
-- NOT CURRENTLY SUPPORTED - will report dummy values
SYNTAX INTEGER {
unknown(1),
succeeded(2),
failed(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The most recent distribution event on a device.
This object will change dynamically based on
the most recently triggered distribution event.
unknown(1) - the distribution event status unknown
succeeded(2) - no distribution event has succeeded
failed(3) - the distribution event failed for some reason."
::= { hpConfig 6 }
hpIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administratively assigned IP address associated with the
device. This can be assigned statically on the
device Console port, or configured via DHCP."
::= { hpConfig 7 }
hpPeerIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administratively assigned IP address associated with a
redundant peer device, configured to work with this device
for failover purposes. This can be assigned statically on the
device Console port, or configured via DHCP. If the device
does not support Failover configuration, or none has been
configured, this object will report 0.0.0.0"
::= { hpConfig 8 }
hpTechSupportEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the current setting for the technical
support access to the device. A value of true(1)
indicates the Technical Support Access has been enabled. A value
of false(2) indicates this access has been disabled. Note
this object should only report true(2) if HP ProCurve Networking
Business Technical Support staff have requested this access
to the HP J8162A XL Access Controller Module for troubleshooting purposes."
DEFVAL { false }
::= { hpConfig 9 }
hpFailedAdminIpAddress OBJECT-TYPE
-- NOT CURRENTLY SUPPORTED - will report dummy values
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address associated with the last failed
authentication to the Administrative UI. If no Administrator
had failed authentication, this object will report 0.0.0.0"
::= { hpConfig 10 }
-- hpStatus
hpNumAccessControllers OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of HP J8162A XL Access Controller Modules known to this system.
If this system is an HP J8162A XL Access Controller Module, this value will be 1.
Otherwise, this value will be the number of HP J8162A XL Access Controller Modules
this system is connected to (i.e. An Access Control Server 740wl
connects to multiple HP J8162A XL Access Controller Module's)."
::= { hpStatus 1 }
hpNumClients OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of active authenticated or unauthenticated
clients known to this system. If this device is an
HP J8162A XL Access Controller Module, then this object reports
the aggregated number of clients across all ports. If this device
is a Access Control Server 740wl, it reports all Clients aggregated
across all HP J8162A XL Access Controller Modules known to this system."
::= { hpStatus 2 }
-- hpNotificationsConfig group
-- Configure system level notifications
hpFailoverNotificationEnabled OBJECT-TYPE
-- NOT CURRENTLY SUPPORTED - will report dummy values
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls whether a hpFailover notification will
be sent in the event of a failover occurrence between a primary
and standby system. By default this object is set to false(2)
for all systems."
::= { hpNotificationsConfig 1 }
hpDistributionNotificationEnabled OBJECT-TYPE
-- NOT CURRENTLY SUPPORTED - will report dummy values
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls whether a hpDistribution notification will
be sent in the event of a distribution event between a central
and remote systems. By default this object is set to false(2)
for all systems."
DEFVAL { false }
::= { hpNotificationsConfig 2 }
hpAdminAuthFailureNotificationEnabled OBJECT-TYPE
-- NOT CURRENTLY SUPPORTED - will report dummy values
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls whether a hpAdminAuthFailure
notification will be sent in the event of a failed
authentication attempt at the administrator login."
DEFVAL { false }
::= { hpNotificationsConfig 3 }
-- Traps
hpSystemTraps OBJECT IDENTIFIER ::= { hpProcurveSystem 0 }
fanDown NOTIFICATION-TYPE
OBJECTS { hpFanNumber }
STATUS current
DESCRIPTION "A fanDown trap signifies that hpFanOperational has
detected an event where the fan is not operating."
::= { hpSystemTraps 1 }
fanUp NOTIFICATION-TYPE
OBJECTS { hpFanNumber }
STATUS current
DESCRIPTION "A fanUp trap signifies that hpFanOperational has
detected an event where the fan is now operating."
::= { hpSystemTraps 2 }
temperatureAlarm NOTIFICATION-TYPE
OBJECTS { hpCpuTemperature }
STATUS current
DESCRIPTION "A temperatureAlarm signifies that the SNMP
entity, acting in an agent role, has detected that the
hpCpuTemperature has a value that exceeds acceptable
tolerances (i.e. it is too hot or too cold)."
::= { hpSystemTraps 3 }
hpFailover NOTIFICATION-TYPE
OBJECTS { hpIpAddress}
STATUS current
DESCRIPTION
"A hpFailover signifies that the SNMP
entity, acting in an agent role, has detected that the
standby system in a primary, redundant operation has
become the primary system. This notification will only
be sent by what was formerly the standby system."
::= { hpSystemTraps 4 }
hpDistributionEvent NOTIFICATION-TYPE
-- NOT CURRENTLY SUPPORTED
OBJECTS { hpDistributionType, hpDistributionStatus}
STATUS current
DESCRIPTION
"A hpDistributionEvent signifies that the SNMP
entity, acting in an agent role, has detected that the
central entity in a distributed system has triggered a
distribution event of hpDistributionType."
::= { hpSystemTraps 5 }
hpAdminAuthFailure NOTIFICATION-TYPE
-- NOT CURRENTLY SUPPORTED
OBJECTS { hpFailedAdminIpAddress}
STATUS current
DESCRIPTION
"A hpAdminAuthFailure signifies that the SNMP
entity, acting in an agent role, has detected that
someone at the address reported by hpAdminIpAddress
has failed to authenticate to the device via
the administrative interface."
::= { hpSystemTraps 6 }
-- conformance information
hpSystemMIBConformance OBJECT IDENTIFIER ::= { hpProcurveSystem 3 }
hpCompliances OBJECT IDENTIFIER ::= { hpSystemMIBConformance 1 }
hpGroups OBJECT IDENTIFIER ::= { hpSystemMIBConformance 2 }
hpSystemMIBCompliance1 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which implement
the HP-SYSTEM-MIB."
MODULE -- this module
MANDATORY-GROUPS { hpSystemGroup, hpConfigGroup }
GROUP hpEnvGroup
DESCRIPTION
"The hpEnvGroup is optional for all entities."
GROUP hpStatusGroup
DESCRIPTION
"The hpStatusGroup is optional for all entities."
GROUP hpNotificationsConfigGroup
DESCRIPTION
"The hpNotificationsConfigGroup is optional for all entities."
GROUP hpNotificationsGroup
DESCRIPTION
"The hpNotificationsGroup is optional for all entities."
OBJECT hpName
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT hpIpAddress
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT hpTechSupportEnabled
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT hpFailoverNotificationEnabled
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT hpDistributionNotificationEnabled
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT hpAdminAuthFailureNotificationEnabled
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
::= { hpCompliances 1 }
-- units of conformance
hpSystemGroup OBJECT-GROUP
OBJECTS { hpProductDescription, hpProductHWVersion, hpProductSWVersion,
hpProductSerialNumber, hpProductLastChange }
STATUS current
DESCRIPTION
"A collection of objects providing system information
applicable to all devices."
::= { hpGroups 1 }
hpEnvGroup OBJECT-GROUP
OBJECTS { hpCpuTemperature, hpPowerSupplyTemperature, hpChassisTemperature,
hpFanNumber, hpFanOperational, hpFanSpeed }
STATUS current
DESCRIPTION
"A collection of objects providing environmental information
applicable to all devices."
::= { hpGroups 2 }
hpConfigGroup OBJECT-GROUP
OBJECTS { hpName, hpSystemID, hpState, hpIpAddress, hpPeerIpAddress,
hpTechSupportEnabled, hpDistributionType, hpDistributionStatus,
hpFailedAdminIpAddress }
STATUS current
DESCRIPTION
"A collection of objects providing configuration information
applicable to all devices."
::= { hpGroups 3 }
hpStatusGroup OBJECT-GROUP
OBJECTS { hpNumAccessControllers, hpNumClients }
STATUS current
DESCRIPTION
"A collection of objects providing statistics
applicable to all HP J8162A XL Access Controller Module like devices."
::= { hpGroups 4 }
hpNotificationsConfigGroup OBJECT-GROUP
OBJECTS { hpFailoverNotificationEnabled,
hpDistributionNotificationEnabled,
hpAdminAuthFailureNotificationEnabled }
STATUS current
DESCRIPTION
"A collection of objects providing notification configuration
information applicable to all devices."
::= { hpGroups 5 }
hpNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS { fanDown, fanUp, temperatureAlarm,
hpFailover, hpDistributionEvent, hpAdminAuthFailure }
STATUS current
DESCRIPTION
"notifications for primary failover, and authorization failures,
applicable to all devices."
::= { hpGroups 6 }
END
|