1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
|
HP-SN-MPLS-TE-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32, Unsigned32, Counter32, Counter64, TimeTicks
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
TruthValue, RowStatus, RowPointer, StorageType,
DisplayString, TimeStamp
FROM SNMPv2-TC
InterfaceIndexOrZero
FROM IF-MIB
mplsMIB, MplsBitRate, MplsBurstSize, MplsLSPID,
MplsTunnelIndex, MplsTunnelInstanceIndex,
MplsTunnelAffinity, MplsLsrIdentifier, MplsPathIndex,
MplsPathIndexOrZero
FROM HP-SN-MPLS-TC-MIB
InetAddressIPv4, InetAddressIPv6
FROM INET-ADDRESS-MIB
snMpls
FROM HP-SN-ROOT-MIB;
mplsTeMIB MODULE-IDENTITY
LAST-UPDATED
"200201041200Z" -- 4 January 2002 12:00:00 GMT
ORGANIZATION
"Multiprotocol Label Switching (MPLS) Working Group"
CONTACT-INFO
"
Cheenu Srinivasan
Postal: Parama Networks, Inc.
1030 Broad Street
Shrewsbury, NJ 07702
Tel: +1-732-544-9120 x731
Email: cheenu@paramanet.com
Arun Viswanathan
Postal: Force10 Networks, Inc.
1440 McCarthy Blvd
Milpitas, CA 95035
Tel: +1-408-571-3516
Email: arun@force10networks.com
Thomas D. Nadeau
Postal: Cisco Systems, Inc.
250 Apollo Drive
Chelmsford, MA 01824
Tel: +1-978-244-3051
Email: tnadeau@cisco.com
"
DESCRIPTION
"This MIB module contains managed object definitions
for MPLS Traffic Engineering (TE) as defined in:
1. Extensions to RSVP for LSP Tunnels, Awduche et
al, RFC 3209, December 2001
2. Constraint-Based LSP Setup using LDP, Jamoussi
(Editor), Internet Draft <draft-ietf-mpls-cr-ldp-
06.txt>, November 2001
3. Requirements for Traffic Engineering Over MPLS,
Awduche, D., Malcolm, J., Agogbua, J., O'Dell, M.,
and J. McManus, RFC 2702, September 1999"
-- Revision history.
REVISION
"200201041200Z" -- 4 January 2002 12:00:00 GMT
DESCRIPTION
"Initial draft version issues as part of RFC XXXX."
::= { mplsMIB 3 }
-- Top level components of this MIB.
-- tables, scalars
mplsTeScalars OBJECT IDENTIFIER ::= { mplsTeMIB 1 }
mplsTeObjects OBJECT IDENTIFIER ::= { mplsTeMIB 2 }
-- traps
mplsTeNotifications OBJECT IDENTIFIER ::= { mplsTeMIB 3 }
mplsTeNotifyPrefix OBJECT IDENTIFIER ::= { mplsTeNotifications 0 }
-- conformance
mplsTeConformance OBJECT IDENTIFIER ::= { mplsTeMIB 4 }
-- MPLS Tunnel scalars.
mplsTunnelConfigured OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of tunnels configured on this device. A
tunnel is considered configured if the
mplsTunnelRowStatus is active(1)."
::= { mplsTeScalars 1 }
mplsTunnelActive OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of tunnels active on this device. A
tunnel is considered active if the
mplsTunnelOperStatus is up(1)."
::= { mplsTeScalars 2 }
mplsTunnelTEDistProto OBJECT-TYPE
SYNTAX BITS {
other (0),
ospf (1),
isis (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The traffic engineering distribution protocol(s)
used by this LSR. Note that an LSR may support more
than one distribution protocol simultaneously."
::= { mplsTeScalars 3 }
mplsTunnelMaxHops OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of hops that can be specified for
a tunnel on this device."
::= { mplsTeScalars 4 }
-- End of MPLS Tunnel scalars.
-- MPLS tunnel table.
mplsTunnelIndexNext OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the next appropriate value to
be used for mplsTunnelIndex when creating entries
in mplsTunnelTable. If the number of unassigned
entries is exhausted, a retrival operation will
return a value of 0. This object may also return a
value of 0 when the LSR is unable to accept
conceptual row creation, for example, if the
mplsTunnelTable is implemented as read-only. To
obtain the value of mplsTunnelIndex for a new
entry, the manager must first issue a management
protocol retrieval operation to obtain the current
value of this object. The agent should modify the
value to reflect the next unassigned index after
each retrieval operation. After a manager retrieves
a value the agent will determine through its local
policy when this index value will be made available
for reuse."
::= { mplsTeObjects 1 }
mplsTunnelTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsTunnelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTunnelTable allows new MPLS tunnels to be
created between an LSR and a remote endpoint, and
existing tunnels to be reconfigured or removed.
Note that only point-to-point tunnel segments are
supported, although multi-point-to-point and point-
to-multi-point connections are supported by an LSR
acting as a cross-connect. Each MPLS tunnel can
thus have one out-segment originating at this LSR
and/or one in-segment terminating at this LSR."
::= { mplsTeObjects 2 }
mplsTunnelEntry OBJECT-TYPE
SYNTAX MplsTunnelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents an MPLS tunnel.
An entry can be created by a network administrator
or by an SNMP agent as instructed by an MPLS
signaling protocol. Whenever a new entry is created
with mplsTunnelIsIf set to true(1), then a
corresponding entry is created in ifTable as well
(see RFC 2863). The ifType of this entry is
mplsTunnel(150)."
REFERENCE
"1. RFC 2863 - The Interfaces Group MIB, McCloghrie,
K., and F. Kastenholtz, June 2000
2. RFC 1700 - Assigned Numbers, Reynolds, J. and J.
Postel, Oct. 1994"
INDEX {
mplsTunnelIndex,
mplsTunnelInstance,
mplsTunnelIngressLSRId,
mplsTunnelEgressLSRId
}
::= { mplsTunnelTable 1 }
MplsTunnelEntry ::= SEQUENCE {
mplsTunnelIndex MplsTunnelIndex,
mplsTunnelInstance MplsTunnelInstanceIndex,
mplsTunnelIngressLSRId MplsLsrIdentifier,
mplsTunnelEgressLSRId MplsLsrIdentifier,
mplsTunnelName DisplayString,
mplsTunnelDescr DisplayString,
mplsTunnelIsIf TruthValue,
mplsTunnelIfIndex InterfaceIndexOrZero,
mplsTunnelXCPointer RowPointer,
mplsTunnelSignallingProto INTEGER,
mplsTunnelSetupPrio Integer32,
mplsTunnelHoldingPrio Integer32,
mplsTunnelSessionAttributes BITS,
mplsTunnelOwner INTEGER,
mplsTunnelLocalProtectInUse TruthValue,
mplsTunnelResourcePointer RowPointer,
mplsTunnelInstancePriority Unsigned32,
mplsTunnelHopTableIndex MplsPathIndexOrZero,
mplsTunnelARHopTableIndex MplsPathIndexOrZero,
mplsTunnelCHopTableIndex MplsPathIndexOrZero,
mplsTunnelPrimaryInstance MplsTunnelInstanceIndex,
mplsTunnelPrimaryTimeUp TimeTicks,
mplsTunnelPathChanges Counter32,
mplsTunnelLastPathChange TimeTicks,
mplsTunnelCreationTime TimeStamp,
mplsTunnelStateTransitions Counter32,
mplsTunnelIncludeAnyAffinity MplsTunnelAffinity,
mplsTunnelIncludeAllAffinity MplsTunnelAffinity,
mplsTunnelExcludeAllAffinity MplsTunnelAffinity,
mplsTunnelPathInUse MplsPathIndexOrZero,
mplsTunnelRole INTEGER,
mplsTunnelTotalUpTime TimeTicks,
mplsTunnelInstanceUpTime TimeTicks,
mplsTunnelAdminStatus INTEGER,
mplsTunnelOperStatus INTEGER,
mplsTunnelRowStatus RowStatus,
mplsTunnelStorageType StorageType
}
mplsTunnelIndex OBJECT-TYPE
SYNTAX MplsTunnelIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies this row."
::= { mplsTunnelEntry 1 }
mplsTunnelInstance OBJECT-TYPE
SYNTAX MplsTunnelInstanceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies an instance of a tunnel. It is
useful to identify multiple instances of tunnels
for the purposes of backup and parallel tunnels."
::= { mplsTunnelEntry 2 }
mplsTunnelIngressLSRId OBJECT-TYPE
SYNTAX MplsLsrIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The purpose of this object is to uniquely identity a
tunnel within a network. When the MPLS signalling
protoocol is rsvp(2) this value SHOULD mimic the
Extended Tunnel Id field in the SESSION object.
When the MPLS signalling protoocol is crldp(3) this
value SHOULD mimic the Ingress LSR Router ID field
in the LSPID TLV object."
REFERENCE
"1. RSVP-TE: Extensions to RSVP for LSP Tunnels,
Awduche et al, RFC 3209, December 2001
2. Constraint-Based LSP Setup using LDP, Jamoussi
(Editor), Internet Draft <draft-ietf-mpls-cr-ldp-
06.txt>, November 2001"
::= { mplsTunnelEntry 3 }
mplsTunnelEgressLSRId OBJECT-TYPE
SYNTAX MplsLsrIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specifies the egress LSR ID."
::= { mplsTunnelEntry 4 }
mplsTunnelName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The canonical name assigned to the tunnel. This name
can be used to refer to the tunnel on the LSR's
console port. If mplsTunnelIsIf is set to true
then the ifName of the interface corresponding to
this tunnel should have a value equal to
mplsTunnelName. Also see the description of ifName
in RFC 2863."
REFERENCE
"RFC 2863 - The Interfaces Group MIB, McCloghrie, K.,
and F. Kastenholtz, June 2000"
::= { mplsTunnelEntry 5 }
mplsTunnelDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A textual string containing information about the
tunnel. If there is no description this object
contains a zero length string."
::= { mplsTunnelEntry 6 }
mplsTunnelIsIf OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes whether or not this tunnel corresponds to an
interface represented in the interfaces group
table. Note that if this variable is set to true
then the ifName of the interface corresponding to
this tunnel should have a value equal to
mplsTunnelName. Also see the description of ifName
in RFC 2863."
REFERENCE
"RFC 2863 - The Interfaces Group MIB, McCloghrie, K.,
and F. Kastenholtz, June 2000"
DEFVAL { false }
::= { mplsTunnelEntry 7 }
mplsTunnelIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelIsIf is set to true, then this value
contains the LSR-assigned ifIndex which corresponds
to an entry in the interfaces table. Otherwise
this variable should contain the value of zero
indicating that a valid ifIndex was not assigned to
this tunnel interface."
REFERENCE
"RFC 2863 - The Interfaces Group MIB, McCloghrie, K.,
and F. Kastenholtz, June 2000"
::= { mplsTunnelEntry 8 }
mplsTunnelXCPointer OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable points to a row in the mplsXCTable.
This table identifies the segments that compose
this tunnel, their characteristics, and
relationships to each other. A value of zeroDotZero
indicates that no LSP has been associated with this
tunnel yet."
REFERENCE
"Srinivasan, C., Viswanathan, A., and T. Nadeau, MPLS
Label Switch Router Management Information Base,
Internet Draft <draft-ietf-mpls-lsr-mib-08.txt>,
December 2001."
::= { mplsTunnelEntry 9 }
mplsTunnelSignallingProto OBJECT-TYPE
SYNTAX INTEGER {
none(1),
rsvp(2),
crldp(3),
other(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The signaling protocol, if any, which was used to
setup this tunnel."
DEFVAL { none }
::= { mplsTunnelEntry 10 }
mplsTunnelSetupPrio OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the setup priority of this tunnel."
REFERENCE
"1. RSVP-TE: Extensions to RSVP for LSP Tunnels,
Awduche et al, RFC 3209, December 2001
2. Constraint-Based LSP Setup using LDP, Jamoussi
(Editor), Internet Draft <draft-ietf-mpls-cr-ldp-
06.txt>, November 2001"
::= { mplsTunnelEntry 11 }
mplsTunnelHoldingPrio OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the holding priority for this tunnel."
REFERENCE
"1. RSVP-TE: Extensions to RSVP for LSP Tunnels,
Awduche et al, RFC3209, December 2001
2. Constraint-Based LSP Setup using LDP, Jamoussi
(Editor), Internet Draft <draft-ietf-mpls-cr-ldp-
06.txt>, November 2001"
::= { mplsTunnelEntry 12 }
mplsTunnelSessionAttributes OBJECT-TYPE
SYNTAX BITS {
fastReroute (0),
mergingPermitted (1),
isPersistent (2),
isPinned (3),
recordRoute(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This bitmask indicates optional session values for
this tunnel. The following describes these
bitfields:
fastRerouteThis flag indicates that the any tunnel
hop may choose to reroute this tunnel without
tearing it down. This flag permits transit routers
to use a local repair mechanism which may result in
violation of the explicit routing of this tunnel.
When a fault is detected on an adjacent downstream
link or node, a transit router can reroute traffic
for fast service restoration.
mergingPermitted This flag permits transit routers
to merge this session with other RSVP sessions for
the purpose of reducing resource overhead on
downstream transit routers, thereby providing
better network scalability.
isPersistent Indicates whether this tunnel should
be restored automatically after a failure occurs.
isPinned This flag indicates whether the loose-
routed hops of this tunnel are to be pinned.
recordRouteThis flag indicates whether or not the
signaling protocol should remember the tunnel path
after it has been signaled."
REFERENCE
"1. RSVP-TE: Extensions to RSVP for LSP Tunnels,
Awduche et al, RFC 3209, December 2001."
::= { mplsTunnelEntry 13 }
mplsTunnelOwner OBJECT-TYPE
SYNTAX INTEGER {
admin(1), -- represents all management entities
rsvp(2),
crldp(3),
policyAgent(4),
other(5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates which protocol created and is responsible
for managing this tunnel. Values rsvp(2) and
crldp(3) should not be used at the head-end of a
MPLS tunnel."
::= { mplsTunnelEntry 14 }
mplsTunnelLocalProtectInUse OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates that the local repair mechanism is in use
to maintain this tunnel (usually in the face of an
outage of the link it was previously routed over)."
::= { mplsTunnelEntry 15 }
mplsTunnelResourcePointer OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable represents a pointer to the traffic
parameter specification for this tunnel. This
value may point at an entry in the
mplsTunnelResourceEntry to indicate which
mplsTunnelResourceEntry is to be assigned to this
segment. This value may optionally point at an
externally defined traffic parameter specification
table. A value of zeroDotZero indicates best-
effort treatment. By having the same value of this
object, two or more segments can indicate resource
sharing."
::= { mplsTunnelEntry 16 }
mplsTunnelInstancePriority OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value indicates which priority, in descending
order, with 0 indicating the lowest priority,
within a group of tunnel instances. A group of
tunnel instances is defined as a set of tunnels
with the same mplsTunnelIndex in this table, but
with a different mplsTunnelInstance. Tunnel group
priorities are used to denote the priority at which
a particular tunnel instance will supercede
another. Instances of tunnels containing the same
mplsTunnelInstancePriority will be used for load
sharing."
DEFVAL { 0 }
::= { mplsTunnelEntry 17 }
mplsTunnelHopTableIndex OBJECT-TYPE
SYNTAX MplsPathIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index into the mplsTunnelHopTable entry that
specifies the explicit route hops for this tunnel."
::= { mplsTunnelEntry 18 }
mplsTunnelARHopTableIndex OBJECT-TYPE
SYNTAX MplsPathIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index into the mplsTunnelARHopTable entry that
specifies the actual hops traversed by the tunnel."
::= { mplsTunnelEntry 19 }
mplsTunnelCHopTableIndex OBJECT-TYPE
SYNTAX MplsPathIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index into the mplsTunnelCHopTable entry that
specifies the computed hops traversed by the
tunnel."
::= { mplsTunnelEntry 20 }
mplsTunnelPrimaryInstance OBJECT-TYPE
SYNTAX MplsTunnelInstanceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the instance index of the primary instance
of this tunnel."
::= { mplsTunnelEntry 21 }
mplsTunnelPrimaryTimeUp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the total time the primary instance of
this tunnel has been active. The primary instance
of this tunnel is defined in
mplsTunnelPrimaryInstance."
::= { mplsTunnelEntry 22 }
mplsTunnelPathChanges OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the number of times the paths has changed
for this tunnel."
::= { mplsTunnelEntry 23 }
mplsTunnelLastPathChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the time since the last path change for
this tunnel."
::= { mplsTunnelEntry 24 }
mplsTunnelCreationTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the value of SysUpTime when the first
instance of this tunnel came into existence."
::= { mplsTunnelEntry 25 }
mplsTunnelStateTransitions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the number of times the state of this
tunnel instance has changed."
::= { mplsTunnelEntry 26 }
mplsTunnelIncludeAnyAffinity OBJECT-TYPE
SYNTAX MplsTunnelAffinity
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A link satisfies the include-any constraint if and
only if the constraint is zero, or the link and the
constraint have a resource class in common."
REFERENCE
"1. RSVP-TE: Extensions to RSVP for LSP Tunnels,
Awduche et al, RFC 3209, December 2001."
::= { mplsTunnelEntry 27 }
mplsTunnelIncludeAllAffinity OBJECT-TYPE
SYNTAX MplsTunnelAffinity
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A link satisfies the include-all constraint if and
only if the link contains all of the adminstrative
groups specified in the constraint."
REFERENCE
"1. RSVP-TE: Extensions to RSVP for LSP Tunnels,
Awduche et al, RFC 3209, December 2001."
::= { mplsTunnelEntry 28 }
mplsTunnelExcludeAllAffinity OBJECT-TYPE
SYNTAX MplsTunnelAffinity
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A link satisfies the exclude-all constraint if and
only if the link contains none of the adminstrative
groups specifie in the constraint."
REFERENCE
"1. RSVP-TE: Extensions to RSVP for LSP Tunnels,
Awduche et al, RFC 3209, December 2001."
::= { mplsTunnelEntry 29 }
mplsTunnelPathInUse OBJECT-TYPE
SYNTAX MplsPathIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value denotes the configured path that was
chosen for this tunnel. This value reflects the
secondary index into mplsTunnelHopTable. This path
may not exactly match the one in
mplsTunnelARHopTable due to the fact that some CSPF
modification may have taken place. See
mplsTunnelARHopTable for the actual path being
taken by the tunnel. A value of zero denotes that
no path is currently in use or available."
::= { mplsTunnelEntry 30 }
mplsTunnelRole OBJECT-TYPE
SYNTAX INTEGER { head(1), transit(2), tail(3) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value signifies the role that this tunnel
entry/instance represents. This value MUST be set
to head(1) at the originating point of the tunnel.
This value MUST be set to transit(2) at transit
points along the tunnel, if transit points are
supported. This value MUST be set to tail(3) at the
terminating point of the tunnel if tunnel tails are
supported."
::= { mplsTunnelEntry 31 }
mplsTunnelTotalUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value represents the aggregate up time for all
instances of this tunnel, if available. If this
value is unavailable, it MUST return a value of 0."
::= { mplsTunnelEntry 32 }
mplsTunnelInstanceUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value identifies the total time that this
tunnel instance's operStatus has been Up(1)."
::= { mplsTunnelEntry 33 }
mplsTunnelAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
-- ready to pass packets
up(1),
down(2),
-- in some test mode
testing(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the desired operational status of this
tunnel."
::= { mplsTunnelEntry 34 }
mplsTunnelOperStatus OBJECT-TYPE
SYNTAX INTEGER {
-- ready to pass packets
up(1),
down(2),
-- in some test mode
testing(3),
-- status cannot be determined
unknown(4),
dormant(5),
-- some component is missing
notPresent(6),
-- down due to the state of
-- lower layer interfaces
lowerLayerDown(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the actual operational status of this
tunnel, which is typically but not limited to, a
function of the state of individual segments of
this tunnel."
::= { mplsTunnelEntry 35 }
mplsTunnelRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable is used to create, modify, and/or
delete a row in this table."
::= { mplsTunnelEntry 36 }
mplsTunnelStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable indicates the storage type for this
object."
::= { mplsTunnelEntry 37 }
-- End of mplsTunnelTable
mplsTunnelHopListIndexNext OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an appropriate value to be used
for mplsTunnelHopListIndex when creating entries in
the mplsTunnelHopTable. If the number of
unassigned entries is exhausted, a retrival
operation will return a value of 0. This object
may also return a value of 0 when the LSR is unable
to accept conceptual row creation, for example, if
the mplsTunnelHopTable is implemented as read-only.
To obtain the value of mplsTunnelHopListIndex for a
new entry in the mplsTunnelHopTable, the manager
issues a management protocol retrieval operation to
obtain the current value of mplsTunnelHopIndex.
After each retrieval operation, the agent should
modify the value to reflect the next unassigned
index. After a manager retrieves a value the agent
will determine through its local policy when this
index value will be made available for reuse."
::= { mplsTeObjects 3 }
mplsTunnelHopTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsTunnelHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTunnelHopTable is used to indicate the hops,
strict or loose, for an MPLS tunnel defined in
mplsTunnelTable, when it is established via
signaling, for the outgoing direction of the
tunnel. Each row in this table is indexed by
mplsTunnelHopListIndex. Each row also has a
secondary index mplsTunnelHopIndex corresponding to
the next hop that this row corresponds to. The
first row in the table is the first hop after the
origination point of the tunnel. In case we want
to specify a particular interface on the
originating LSR of an outgoing tunnel by which we
want packets to exit the LSR, we specify this as
the first hop for this tunnel in
mplsTunnelHopTable."
::= { mplsTeObjects 4 }
mplsTunnelHopEntry OBJECT-TYPE
SYNTAX MplsTunnelHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a tunnel hop. An
entry is created by a network administrator for
signaled ERLSP set up by an MPLS signaling
protocol."
INDEX {
mplsTunnelHopListIndex,
mplsTunnelHopPathOptionIndex,
mplsTunnelHopIndex
}
::= { mplsTunnelHopTable 1 }
MplsTunnelHopEntry ::= SEQUENCE {
mplsTunnelHopListIndex MplsPathIndex,
mplsTunnelHopPathOptionIndex MplsPathIndex,
mplsTunnelHopIndex MplsPathIndex,
mplsTunnelHopAddrType INTEGER,
mplsTunnelHopIpv4Addr InetAddressIPv4,
mplsTunnelHopIpv4PrefixLen Unsigned32,
mplsTunnelHopIpv6Addr InetAddressIPv6,
mplsTunnelHopIpv6PrefixLen Unsigned32,
mplsTunnelHopAsNumber Unsigned32,
mplsTunnelHopLspId MplsLSPID,
mplsTunnelHopType INTEGER,
mplsTunnelHopIncludeExclude INTEGER,
mplsTunnelHopPathOptionName DisplayString,
mplsTunnelHopEntryPathComp INTEGER,
mplsTunnelHopRowStatus RowStatus,
mplsTunnelHopStorageType StorageType
}
mplsTunnelHopListIndex OBJECT-TYPE
SYNTAX MplsPathIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Primary index into this table identifying a
particular explicit route object."
::= { mplsTunnelHopEntry 1 }
mplsTunnelHopPathOptionIndex OBJECT-TYPE
SYNTAX MplsPathIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Secondary index into this table identifying a
particular group of hops representing a particular
configured path. This is otherwise known as a path
option."
::= { mplsTunnelHopEntry 2 }
mplsTunnelHopIndex OBJECT-TYPE
SYNTAX MplsPathIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Secondary index into this table identifying a
particular hop."
::= { mplsTunnelHopEntry 3 }
mplsTunnelHopAddrType OBJECT-TYPE
SYNTAX INTEGER {
ipV4(1),
ipV6(2),
asNumber(3),
lspid(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes the address type of this tunnel hop. Note
that lspId(4) is a valid option only for tunnels
signaled via CRLDP."
DEFVAL { ipV4 }
::= { mplsTunnelHopEntry 4 }
mplsTunnelHopIpv4Addr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If mplsTunnelHopAddrType is set to ipV4(1), then
this value will contain the IPv4 address of this
hop. If mplsTunnelHopAddrType is set to lspid(4),
then this value will contain the Ingress LSR Router
ID of the Tunnel. This object is otherwise
insignificant and should contain a value of 0."
::= { mplsTunnelHopEntry 5 }
mplsTunnelHopIpv4PrefixLen OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If mplsTunnelHopAddrType is ipV4(1), then the prefix
length for this hop's IPv4 address is contained
herein. This object is otherwise insignificant and
should contain a value of 0."
::= { mplsTunnelHopEntry 6 }
mplsTunnelHopIpv6Addr OBJECT-TYPE
SYNTAX InetAddressIPv6
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If the mplsTunnelHopAddrType is set to ipV6(2), then
this variable contains the IPv6 address of this
hop. This object is otherwise insignificant and
should contain a value of 0."
::= { mplsTunnelHopEntry 7 }
mplsTunnelHopIpv6PrefixLen OBJECT-TYPE
SYNTAX Unsigned32 (0..128)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If mplsTunnelHopAddrType is set to ipV6(2), this
value will contain the prefix length for this hop's
IPv6 address. This object is otherwise
insignificant and should contain a value of 0."
::= { mplsTunnelHopEntry 8 }
mplsTunnelHopAsNumber OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If mplsTunnelHopAddrType is set to asNumber(3), then
this value will contain the AS number of this hop.
This object is otherwise insignificant and should
contain a value of 0 to indicate this fact."
::= { mplsTunnelHopEntry 9 }
mplsTunnelHopLspId OBJECT-TYPE
SYNTAX MplsLSPID
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If mplsTunnelHopAddrType is set to lspid(4), then
this value will contain the LSPID of a tunnel of
this hop. The present tunnel being configured is
tunneled through this hop (using label stacking).
This object is otherwise insignificant and should
contain a value of 0 to indicate this fact."
::= { mplsTunnelHopEntry 10 }
mplsTunnelHopType OBJECT-TYPE
SYNTAX INTEGER {
strict(1),
loose(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes whether this tunnel hop is routed in a
strict or loose fashion."
::= { mplsTunnelHopEntry 11 }
mplsTunnelHopIncludeExclude OBJECT-TYPE
SYNTAX INTEGER {
include(1),
exclude(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If this value is set to include(1), then this
indicates that this hop must be included in the
tunnel's path. If this value is set to exclude(2),
then this hop must be avoided when calculating the
path for this tunnel. The default value of this
object is include(1), so that by default all
indicated hops are included in the CSPF path
computation."
DEFVAL { include }
::= { mplsTunnelHopEntry 12 }
mplsTunnelHopPathOptionName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The description of this series of hops as they
relate to the specified path option."
::= { mplsTunnelHopEntry 13 }
mplsTunnelHopEntryPathComp OBJECT-TYPE
SYNTAX INTEGER {
dynamic(1), -- CSPF computed
explicit(2) -- strict hop
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If this value is set to dynamic, then the user
should only specify the source and destination of
the path and expect that the CSPF will calculate
the remainder of the path. If this value is set to
explicit, the user should specify the entire path
for the tunnel to take. This path may contain
strict or loose hops. Each hop along a specific
path should have this object set to the same value"
::= { mplsTunnelHopEntry 14 }
mplsTunnelHopRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable is used to create, modify, and/or
delete a row in this table."
::= { mplsTunnelHopEntry 15 }
mplsTunnelHopStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable indicates the storage type for this
object."
::= { mplsTunnelHopEntry 16 }
-- End of mplsTunnelHopTable
-- Begin of mplsTunnelResourceTable
mplsTunnelResourceIndexNext OBJECT-TYPE
SYNTAX Unsigned32 (0.. 2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the next appropriate value to
be used for mplsTunnelResourceIndex when creating
entries in the mplsTunnelResourceTable. If the
number of unassigned entries is exhausted, a
retrival operation will return a value of 0. This
object may also return a value of 0 when the LSR is
unable to accept conceptual row creation, for
example, if the mplsTunnelTable is implemented as
read-only. To obtain the mplsTunnelResourceIndex
value for a new entry, the manager must first issue
a management protocol retrieval operation to obtain
the current value of this object. The agent should
modify the value to reflect the next unassigned
index after each retrieval operation. After a
manager retrieves a value the agent will determine
through its local policy when this index value will
be made available for reuse."
::= { mplsTeObjects 5 }
mplsTunnelResourceTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsTunnelResourceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTunnelResourceTable allows a manager to
specify which resources are desired for an MPLS
tunnel. This table also allows several tunnels to
point to a single entry in this table, implying
that these tunnels should share resources."
::= { mplsTeObjects 6 }
mplsTunnelResourceEntry OBJECT-TYPE
SYNTAX MplsTunnelResourceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a set of resources
for an MPLS tunnel. An entry can be created by a
network administrator or by an SNMP agent as
instructed by any MPLS signaling protocol."
INDEX { mplsTunnelResourceIndex }
::= { mplsTunnelResourceTable 1 }
MplsTunnelResourceEntry ::= SEQUENCE {
mplsTunnelResourceIndex Unsigned32,
mplsTunnelResourceMaxRate MplsBitRate,
mplsTunnelResourceMeanRate MplsBitRate,
mplsTunnelResourceMaxBurstSize MplsBurstSize,
mplsTunnelResourceMeanBurstSize MplsBurstSize,
mplsTunnelResourceExcessBurstSize MplsBurstSize,
mplsTunnelResourceFrequency INTEGER,
mplsTunnelResourceWeight Unsigned32,
mplsTunnelResourceRowStatus RowStatus,
mplsTunnelResourceStorageType StorageType
}
mplsTunnelResourceIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies this row."
::= { mplsTunnelResourceEntry 1 }
mplsTunnelResourceMaxRate OBJECT-TYPE
SYNTAX MplsBitRate
UNITS "bits per second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum rate in bits/second. Note that setting
mplsTunnelResourceMaxRate,
mplsTunnelResourceMeanRate, and
mplsTunnelResourceMaxBurstSize to 0 indicates best-
effort treatment.
This object is copied to an instance of
mplsTrafficParamMaxRate in mplsTrafficParamTable
the OID of which is copied into the corresponding
mplsInSegmentTrafficParamPtr."
REFERENCE
"Srinivasan, C., Viswanathan, A., and T. Nadeau, MPLS
Label Switch Router Management Information Base,
Internet Draft <draft-ietf-mpls-lsr-mib-08.txt>,
December 2001."
::= { mplsTunnelResourceEntry 2 }
mplsTunnelResourceMeanRate OBJECT-TYPE
SYNTAX MplsBitRate
UNITS "bits per second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is copied into an instance of
mplsTrafficParamMeanRate in the
mplsTrafficParamTable. The OID of this table entry
is then copied into the corresponding
mplsInSegmentTrafficParamPtr.
When resource allocation is performed as requested
by this TSpec object, it is copied into an entry in
mplsTrafficParamTable [LSRMIB]:
mplsTunnelInMeanRate to mplsTrafficParamMeanRate.
The OID of this entry is copied to
mplsInSegmentTrafficParamPtr of the corresponding
in-segment entry."
REFERENCE
"Srinivasan, C., Viswanathan, A., and T. Nadeau, MPLS
Label Switch Router Management Information Base,
Internet Draft <draft-ietf-mpls-lsr-mib-08.txt>,
December 2001."
::= { mplsTunnelResourceEntry 3 }
mplsTunnelResourceMaxBurstSize OBJECT-TYPE
SYNTAX MplsBurstSize
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum burst size in bytes. This object is
copied to mplsInSegmentMaxBurstSize of the
corresponding in-segment.
When resource allocation is performed as requested
by this TSpec object, it is copied into an entry in
mplsTrafficParamTable [LSRMIB]:
mplsTunnelInMaxBurstSize to
mplsTrafficParamMaxBurstSize. The OID of this entry
is copied to mplsInSegmentTrafficParamPtr of the
corresponding in-segment entry."
REFERENCE
"Srinivasan, C., Viswanathan, A., and T. Nadeau, MPLS
Label Switch Router Management Information Base,
Internet Draft <draft-ietf-mpls-lsr-mib-08.txt>,
December 2001."
::= { mplsTunnelResourceEntry 4 }
mplsTunnelResourceMeanBurstSize OBJECT-TYPE
SYNTAX MplsBurstSize
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The mean burst size in bytes. The implementations
which do not implement this variable must return 0
for this value and must not allow a user to set
this value."
::= { mplsTunnelResourceEntry 5 }
mplsTunnelResourceExcessBurstSize OBJECT-TYPE
SYNTAX MplsBurstSize
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Excess burst size in bytes. The implementations
which do not implement this variable must return 0
for this value and must not allow a user to set
this value."
REFERENCE
"CR-LDP Specification, Section 4.3."
::= { mplsTunnelResourceEntry 6 }
mplsTunnelResourceFrequency OBJECT-TYPE
SYNTAX INTEGER {
unspecified(1),
frequent(2),
veryFrequent(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The granularity of the availability of committed
rate. The implementations which do not implement
this variable must return unspecified(1) for this
value and must not allow a user to set this value."
REFERENCE
"CR-LDP Specification, Section 4.3."
::= { mplsTunnelResourceEntry 7 }
mplsTunnelResourceWeight OBJECT-TYPE
SYNTAX Unsigned32(0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The relative weight for using excess bandwidth above
its committed rate. The value of 0 means that
weight is not applicable for the CR-LSP."
REFERENCE
"CR-LDP Specification, Section 4.3."
::= { mplsTunnelResourceEntry 8 }
mplsTunnelResourceRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable is used to create, modify, and/or
delete a row in this table."
::= { mplsTunnelResourceEntry 9 }
mplsTunnelResourceStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable indicates the storage type for this
object."
::= { mplsTunnelResourceEntry 10 }
-- End mplsTunnelResourceTable
-- Tunnel Actual Route Hop table.
mplsTunnelARHopTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsTunnelARHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTunnelARHopTable is used to indicate the
hops, strict or loose, for an MPLS tunnel defined
in mplsTunnelTable, as reported by the MPLS
signaling protocol, for the outgoing direction of
the tunnel. Each row in this table is indexed by
mplsTunnelARHopListIndex. Each row also has a
secondary index mplsTunnelARHopIndex, corresponding
to the next hop that this row corresponds to. The
first row in the table is the first hop after the
origination point of the tunnel. In case we want
to specify a particular interface on the
originating LSR of an outgoing tunnel by which we
want packets to exit the LSR, we specify this as
the first hop for this tunnel in
mplsTunnelARHopTable.
Please note that since the information necessary to
build entries within this table are not provided by
some MPLS signaling protocols, implementation of
this table is optional. Furthermore, since the
information in this table is actually provided by
the MPLS signaling protocol after the path has been
set-up, the entries in this table are provided only
for observation, and hence, all variables in this
table are accessible exclusively as read-only."
::= { mplsTeObjects 7 }
mplsTunnelARHopEntry OBJECT-TYPE
SYNTAX MplsTunnelARHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a tunnel hop. An
entry is created by a network administrator for
signaled ERLSP set up by an MPLS signaling
protocol."
INDEX { mplsTunnelARHopListIndex, mplsTunnelARHopIndex }
::= { mplsTunnelARHopTable 1 }
MplsTunnelARHopEntry ::= SEQUENCE {
mplsTunnelARHopListIndex MplsPathIndex,
mplsTunnelARHopIndex MplsPathIndex,
mplsTunnelARHopAddrType INTEGER,
mplsTunnelARHopIpv4Addr InetAddressIPv4,
mplsTunnelARHopIpv4PrefixLen Unsigned32,
mplsTunnelARHopIpv6Addr InetAddressIPv6,
mplsTunnelARHopIpv6PrefixLen Unsigned32,
mplsTunnelARHopAsNumber Unsigned32,
mplsTunnelARHopLspId MplsLSPID
}
mplsTunnelARHopListIndex OBJECT-TYPE
SYNTAX MplsPathIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Primary index into this table identifying a
particular recorded hop list."
::= { mplsTunnelARHopEntry 1 }
mplsTunnelARHopIndex OBJECT-TYPE
SYNTAX MplsPathIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Secondary index into this table identifying the
particular hop."
::= { mplsTunnelARHopEntry 2 }
mplsTunnelARHopAddrType OBJECT-TYPE
SYNTAX INTEGER {
ipV4(1),
ipV6(2),
asNumber(3),
lspId(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Denotes the address type of this tunnel hop."
DEFVAL { ipV4 }
::= { mplsTunnelARHopEntry 3 }
mplsTunnelARHopIpv4Addr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelARHopAddrType is set to ipV4(1), then
this value will contain the IPv4 address of this
hop. This object is otherwise insignificant and
should contain a value of 0."
::= { mplsTunnelARHopEntry 4 }
mplsTunnelARHopIpv4PrefixLen OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelARHopAddrType is ipV4(1), then the
prefix length for this hop's IPv4 address is
contained herein. This object is otherwise
insignificant and should contain a value of 0."
::= { mplsTunnelARHopEntry 5 }
mplsTunnelARHopIpv6Addr OBJECT-TYPE
SYNTAX InetAddressIPv6
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the mplsTunnelARHopAddrType is set to ipV6(2),
then this variable contains the IPv6 address of
this hop. This object is otherwise insignificant
and should contain a value of 0."
::= { mplsTunnelARHopEntry 6 }
mplsTunnelARHopIpv6PrefixLen OBJECT-TYPE
SYNTAX Unsigned32 (0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelARHopAddrType is set to ipV6(2), this
value will contain the prefix length for this hop's
IPv6 address. This object is otherwise
insignificant and should contain a value of 0."
::= { mplsTunnelARHopEntry 7 }
mplsTunnelARHopAsNumber OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelARHopAddrType is set to asNumber(3),
then this value will contain the AS number of this
hop. This object is otherwise insignificant and
should contain a value of 0 to indicate this fact."
::= { mplsTunnelARHopEntry 8 }
mplsTunnelARHopLspId OBJECT-TYPE
SYNTAX MplsLSPID
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelARHopAddrType is set to lspid(4), then
this value will contain the LSP ID of this hop.
This object is otherwise insignificant and should
contain a value of 0 to indicate this fact."
::= { mplsTunnelARHopEntry 9 }
-- End of mplsTunnelARHopTable
-- Tunnel Computed Hop table.
mplsTunnelCHopTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsTunnelCHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTunnelCHopTable is used to indicate the
hops, strict or loose, for an MPLS tunnel defined
in mplsTunnelTable, as computed by a constraint-
based routing protocol, based on the
mplsTunnelHopTable for the outgoing direction of
the tunnel. Each row in this table is indexed by
mplsTunnelCHopListIndex. Each row also has a
secondary index mplsTunnelCHopIndex, corresponding
to the next hop that this row corresponds to. The
first row in the table is the first hop after the
origination point of the tunnel. In case we want
to specify a particular interface on the
originating LSR of an outgoing tunnel by which we
want packets to exit the LSR, we specify this as
the first hop for this tunnel in
mplsTunnelCHopTable.
Please note that since the information necessary to
build entries within this table may not be
supported by some LSRs, implementation of this
table is optional. Furthermore, since the
information in this table is actually provided by
routing protocol after the path has been computed,
the entries in this table are provided only for
observation, and hence, all variables in this table
are accessible exclusively as read-only."
::= { mplsTeObjects 8 }
mplsTunnelCHopEntry OBJECT-TYPE
SYNTAX MplsTunnelCHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a tunnel hop. An
entry in this table is created by a constraint-
based routing protocol based on the hops specified
in the corresponding mplsTunnelHopTable."
INDEX { mplsTunnelCHopListIndex, mplsTunnelCHopIndex }
::= { mplsTunnelCHopTable 1 }
MplsTunnelCHopEntry ::= SEQUENCE {
mplsTunnelCHopListIndex MplsPathIndex,
mplsTunnelCHopIndex MplsPathIndex,
mplsTunnelCHopAddrType INTEGER,
mplsTunnelCHopIpv4Addr InetAddressIPv4,
mplsTunnelCHopIpv4PrefixLen Unsigned32,
mplsTunnelCHopIpv6Addr InetAddressIPv6,
mplsTunnelCHopIpv6PrefixLen Unsigned32,
mplsTunnelCHopAsNumber Unsigned32,
mplsTunnelCHopLspId MplsLSPID,
mplsTunnelCHopType INTEGER
}
mplsTunnelCHopListIndex OBJECT-TYPE
SYNTAX MplsPathIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Primary index into this table identifying a
particular computed hop list."
::= { mplsTunnelCHopEntry 1 }
mplsTunnelCHopIndex OBJECT-TYPE
SYNTAX MplsPathIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Secondary index into this table identifying the
particular hop."
::= { mplsTunnelCHopEntry 2 }
mplsTunnelCHopAddrType OBJECT-TYPE
SYNTAX INTEGER {
ipV4(1),
ipV6(2),
asNumber(3),
lspId(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Denotes the address type of this tunnel hop. Note
that lspId(4) is a valid option only for tunnels
signaled via CRLDP."
DEFVAL { ipV4 }
::= { mplsTunnelCHopEntry 3 }
mplsTunnelCHopIpv4Addr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelCHopAddrType is set to ipV4(1), then
this value will contain the IPv4 address of this
hop. This object is otherwise insignificant and
should contain a value of 0."
::= { mplsTunnelCHopEntry 4 }
mplsTunnelCHopIpv4PrefixLen OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelCHopAddrType is ipV4(1), then the
prefix length for this hop's IPv4 address is
contained herein. This object is otherwise
insignificant and should contain a value of 0."
::= { mplsTunnelCHopEntry 5 }
mplsTunnelCHopIpv6Addr OBJECT-TYPE
SYNTAX InetAddressIPv6
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the mplsTunnelCHopAddrType is set to ipV6(2),
then this variable contains the IPv6 address of
this hop. This object is otherwise insignificant
and should contain a value of 0."
::= { mplsTunnelCHopEntry 6 }
mplsTunnelCHopIpv6PrefixLen OBJECT-TYPE
SYNTAX Unsigned32 (0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelCHopAddrType is set to ipV6(2), this
value will contain the prefix length for this hop's
IPv6 address. This object is otherwise
insignificant and should contain a value of 0."
::= { mplsTunnelCHopEntry 7 }
mplsTunnelCHopAsNumber OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelCHopAddrType is set to asNumber(3),
then this value will contain the AS number of this
hop. This object is otherwise insignificant and
should contain a value of 0 to indicate this fact."
::= { mplsTunnelCHopEntry 8 }
mplsTunnelCHopLspId OBJECT-TYPE
SYNTAX MplsLSPID
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If mplsTunnelCHopAddrType is set to lspid(4), then
this value will contain the LSP ID of this hop.
This object is otherwise insignificant and should
contain a value of 0 to indicate this fact."
::= { mplsTunnelCHopEntry 9 }
mplsTunnelCHopType OBJECT-TYPE
SYNTAX INTEGER {
strict(1),
loose(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Denotes whether this is tunnel hop is routed in a
strict or loose fashion."
::= { mplsTunnelCHopEntry 10 }
-- End of mplsTunnelCHopTable
-- MPLS Tunnel Performance Table.
mplsTunnelPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsTunnelPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides per-tunnel MPLS performance
information."
::= { mplsTeObjects 9 }
mplsTunnelPerfEntry OBJECT-TYPE
SYNTAX MplsTunnelPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table is created by the LSR for
every tunnel. Its is an extension to
mplsTunnelEntry."
AUGMENTS { mplsTunnelEntry }
::= { mplsTunnelPerfTable 1 }
MplsTunnelPerfEntry ::= SEQUENCE {
mplsTunnelPerfPackets Counter32,
mplsTunnelPerfHCPackets Counter64,
mplsTunnelPerfErrors Counter32,
mplsTunnelPerfBytes Counter32,
mplsTunnelPerfHCBytes Counter64
}
mplsTunnelPerfPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets forwarded by the tunnel."
::= { mplsTunnelPerfEntry 1 }
mplsTunnelPerfHCPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High capacity counter for number of packets
forwarded by the tunnel."
::= { mplsTunnelPerfEntry 2 }
mplsTunnelPerfErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of errored packets."
::= { mplsTunnelPerfEntry 3 }
mplsTunnelPerfBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bytes forwarded by the tunnel."
::= { mplsTunnelPerfEntry 4 }
mplsTunnelPerfHCBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High capacity counter for number of bytes forwarded
by the tunnel."
::= { mplsTunnelPerfEntry 5 }
-- End of mplsTunnelPerfTable
-- CR-LDP Tunnel Resource Table
mplsTunnelCRLDPResTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsTunnelCRLDPResEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTunnelCRLDPResTable allows a manager to
specify which CR-LDP-specific resources are desired
for an MPLS tunnel if that tunnel is signaled using
CR-LDP. Note that these attributes are in addition
to those specified in mplsTunnelResourceTable. This
table also allows several tunnels to point to a
single entry in this table, implying that these
tunnels should share resources."
::= { mplsTeObjects 10 }
mplsTunnelCRLDPResEntry OBJECT-TYPE
SYNTAX MplsTunnelCRLDPResEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a set of resources
for an MPLS tunnel established using CRLDP
(mplsTunnelSignallingProto equal to crldp (3)). An
entry can be created by a network administrator or
by an SNMP agent as instructed by any MPLS
signaling protocol."
INDEX { mplsTunnelResourceIndex }
::= { mplsTunnelCRLDPResTable 1 }
MplsTunnelCRLDPResEntry ::= SEQUENCE {
mplsTunnelCRLDPResMeanBurstSize MplsBurstSize,
mplsTunnelCRLDPResExcessBurstSize MplsBurstSize,
mplsTunnelCRLDPResFrequency INTEGER,
mplsTunnelCRLDPResWeight Unsigned32,
mplsTunnelCRLDPResFlags Unsigned32,
mplsTunnelCRLDPResRowStatus RowStatus,
mplsTunnelCRLDPResStorageType StorageType
}
mplsTunnelCRLDPResMeanBurstSize OBJECT-TYPE
SYNTAX MplsBurstSize
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The mean burst size in bytes."
::= { mplsTunnelCRLDPResEntry 2 }
mplsTunnelCRLDPResExcessBurstSize OBJECT-TYPE
SYNTAX MplsBurstSize
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Excess burst size in bytes."
REFERENCE
"CR-LDP Specification, Section 4.3."
::= { mplsTunnelCRLDPResEntry 3 }
mplsTunnelCRLDPResFrequency OBJECT-TYPE
SYNTAX INTEGER {
unspecified(1),
frequent(2),
veryFrequent(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The granularity of the availability of committed
rate."
REFERENCE
"CR-LDP Specification, Section 4.3."
::= { mplsTunnelCRLDPResEntry 4 }
mplsTunnelCRLDPResWeight OBJECT-TYPE
SYNTAX Unsigned32(0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The relative weight for using excess bandwidth above
its committed rate. The value of 0 means that
weight is not applicable for the CR-LSP."
REFERENCE
"CR-LDP Specification, Section 4.3."
DEFVAL { 0 }
::= { mplsTunnelCRLDPResEntry 5 }
mplsTunnelCRLDPResFlags OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of the 1 byte Flags conveyed as part of
the traffic parameters during the establishment of
the CRLSP. The bits in this object are to be
interpreted as follows.
+--+--+--+--+--+--+--+--+
| Res |F6|F5|F4|F3|F2|F1|
+--+--+--+--+--+--+--+--+
Res - These bits are reserved. Zero on transmission.
Ignored on receipt.
F1 - Corresponds to the PDR.
F2 - Corresponds to the PBS.
F3 - Corresponds to the CDR.
F4 - Corresponds to the CBS.
F5 - Corresponds to the EBS.
F6 - Corresponds to the Weight.
Each flag if is a Negotiable Flag corresponding to a
Traffic Parameter. The Negotiable Flag value zero
denotes Not Negotiable and value one denotes
Negotiable."
REFERENCE
"1. Section 4.3, Constraint-Based LSP Setup using
LDP, Jamoussi (Editor), Internet Draft <draft-ietf-
mpls-crldp-06.txt>, November 2001"
DEFVAL { 0 }
::= { mplsTunnelCRLDPResEntry 6 }
mplsTunnelCRLDPResRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable is used to create, modify, and/or
delete a row in this table."
::= { mplsTunnelCRLDPResEntry 7 }
mplsTunnelCRLDPResStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable indicates the storage type for this
object."
::= { mplsTunnelCRLDPResEntry 8 }
-- Notifications.
mplsTunnelTrapEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If this object is true, then it enables the
generation of mplsTunnelUp and mplsTunnelDown
traps, otherwise these traps are not emitted."
DEFVAL { false }
::= { mplsTeObjects 11 }
mplsTunnelUp NOTIFICATION-TYPE
OBJECTS {
mplsTunnelAdminStatus,
mplsTunnelOperStatus
}
STATUS current
DESCRIPTION
"This notification is generated when a
mplsTunnelOperStatus object for one of the
configured tunnels is about to leave the down state
and transition into some other state (but not into
the notPresent state). This other state is
indicated by the included value of
mplsTunnelOperStatus."
::= { mplsTeNotifyPrefix 1 }
mplsTunnelDown NOTIFICATION-TYPE
OBJECTS {
mplsTunnelAdminStatus,
mplsTunnelOperStatus
}
STATUS current
DESCRIPTION
"This notification is generated when a
mplsTunnelOperStatus object for one of the
configured tunnels is about to enter the down state
from some other state (but not from the notPresent
state). This other state is indicated by the
included value of mplsTunnelOperStatus."
::= { mplsTeNotifyPrefix 2 }
mplsTunnelRerouted NOTIFICATION-TYPE
OBJECTS {
mplsTunnelAdminStatus,
mplsTunnelOperStatus
}
STATUS current
DESCRIPTION
"This notification is generated when a tunnel is
rerouted. If the actual path is used, then this
tunnel's entry MAY contain the new path for this
tunnel some time after this trap is issued by the
agent."
::= { mplsTeNotifyPrefix 3 }
mplsTunnelReoptimized NOTIFICATION-TYPE
OBJECTS {
mplsTunnelAdminStatus,
mplsTunnelOperStatus
}
STATUS current
DESCRIPTION
"This notification is generated when a tunnel is
reoptimized. If the actual path is used, then this
tunnel's entry MAY contain the new path for this
tunnel some time after this trap is issued by the
agent."
::= { mplsTeNotifyPrefix 4 }
-- End of notifications.
-- Module compliance.
mplsTeGroups
OBJECT IDENTIFIER ::= { mplsTeConformance 1 }
mplsTeCompliances
OBJECT IDENTIFIER ::= { mplsTeConformance 2 }
mplsTeModuleCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for agents that support the
MPLS TE MIB."
MODULE -- this module
-- The mandatory group has to be implemented by all
-- LSRs that originate/terminate ESLSPs/tunnels.
-- In addition, depending on the type of tunnels
-- supported, other groups become mandatory as
-- explained below.
MANDATORY-GROUPS {
mplsTunnelGroup,
mplsTunnelScalarGroup
}
GROUP mplsTunnelManualGroup
DESCRIPTION
"This group is mandatory for devices which support
manual configuration of tunnels, in addition to
mplsTunnelGroup. The following constraints apply:
mplsTunnelSignallingProto should be at least read-
only with a value of none(1)."
GROUP mplsTunnelSignaledGroup
DESCRIPTION
"This group is mandatory for devices which support
signaled tunnel set up, in addition to
mplsTunnelGroup. The following constraints apply:
mplsTunnelSignallingProto should be at least read-
only returning a value of ldp(2), or rsvp(3)."
GROUP mplsTunnelIsNotIntfcGroup
DESCRIPTION
"This group is mandatory for devices which support
tunnels that are not interfaces, in addition to
mplsTunnelGroup. The following constraints apply:
mplsTunnelIsIf must at least be read-only
returning false(1)."
GROUP mplsTunnelIsIntfcGroup
DESCRIPTION
"This group is mandatory for devices which support
tunnels that are interfaces, in addition to
mplsTunnelGroup. The following constraints apply:
mplsTunnelIsIf must at least be read-only
returning true(2)."
GROUP mplsTunnelOptionalGroup
DESCRIPTION
"Objects in this group are optional."
-- mplsTunnelTable
OBJECT mplsTunnelName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelDescr
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelIsIf
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelIfIndex
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelXCPointer
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelSignallingProto
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelSetupPrio
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHoldingPrio
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelSessionAttributes
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelOwner
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelLocalProtectInUse
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourcePointer
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelInstancePriority
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopTableIndex
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelPrimaryInstance
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelPrimaryTimeUp
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelPathChanges
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelLastPathChange
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelCreationTime
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelStateTransitions
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelARHopTableIndex
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelCHopTableIndex
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelAdminStatus
SYNTAX INTEGER { up (1), down (2) }
MIN-ACCESS read-only
DESCRIPTION
"Only up and down states must be supported. Write
access is not required."
OBJECT mplsTunnelOperStatus
SYNTAX INTEGER { up (1), down (2) }
DESCRIPTION
"Only up and down states must be supported. Write
access is not required."
OBJECT mplsTunnelRowStatus
SYNTAX INTEGER {
active(1),
notInService(2),
createAndGo(4),
destroy(6)
}
MIN-ACCESS read-only
DESCRIPTION
"The notReady(3) and createAndWait(5) states need
not be supported. Write access is not required."
OBJECT mplsTunnelStorageType
SYNTAX INTEGER { other(1) }
MIN-ACCESS read-only
DESCRIPTION
"Only other (1) needs to be supported."
OBJECT mplsTunnelPathInUse
MIN-ACCESS read-only
DESCRIPTION
"Read-only support is required."
OBJECT mplsTunnelRole
SYNTAX INTEGER { head(1) }
MIN-ACCESS read-only
DESCRIPTION
"Only support for head is required."
OBJECT mplsTunnelTotalUpTime
MIN-ACCESS read-only
DESCRIPTION
"Read-only support is required."
OBJECT mplsTunnelInstanceUpTime
MIN-ACCESS read-only
DESCRIPTION
"Read-only support is required."
-- mplsTunnelHopTable
OBJECT mplsTunnelHopAddrType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopIpv4Addr
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopIpv4PrefixLen
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopIpv6Addr
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopIpv6PrefixLen
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopAsNumber
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopLspId
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopType
SYNTAX INTEGER { strict(1) }
MIN-ACCESS read-only
DESCRIPTION
"loose(2) need not be supported. Write access is
not required."
OBJECT mplsTunnelHopIncludeExclude
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopPathOptionName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopEntryPathComp
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelHopRowStatus
SYNTAX INTEGER {
active(1),
notInService(2),
createAndGo(4),
destroy(6)
}
MIN-ACCESS read-only
DESCRIPTION
"The notReady(3) and createAndWait(5) states need
not be supported. Write access is not required."
OBJECT mplsTunnelHopStorageType
SYNTAX INTEGER { other(1) }
MIN-ACCESS read-only
DESCRIPTION
"Only other (1) needs to be supported."
-- mplsTunnelResourceTable
OBJECT mplsTunnelResourceMaxRate
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourceMeanRate
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourceMaxBurstSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourceMeanBurstSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourceExcessBurstSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourceFrequency
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourceWeight
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelResourceRowStatus
SYNTAX INTEGER {
active(1),
notInService(2),
createAndGo(4),
destroy(6)
}
MIN-ACCESS read-only
DESCRIPTION
"The notReady(3) and createAndWait(5) states need
not be supported. Write access is not required."
OBJECT mplsTunnelResourceStorageType
SYNTAX INTEGER { other(1) }
MIN-ACCESS read-only
DESCRIPTION
"Only other (1) needs to be supported."
-- mplsTunnelPerfTable
OBJECT mplsTunnelPerfPackets
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelPerfHCPackets
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelPerfErrors
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelPerfBytes
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelPerfHCBytes
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { mplsTeCompliances 1 }
-- Units of conformance.
mplsTunnelGroup OBJECT-GROUP
OBJECTS {
mplsTunnelIndexNext,
mplsTunnelName,
mplsTunnelDescr,
mplsTunnelOwner,
mplsTunnelXCPointer,
mplsTunnelIfIndex,
mplsTunnelHopTableIndex,
mplsTunnelARHopTableIndex,
mplsTunnelCHopTableIndex,
mplsTunnelAdminStatus,
mplsTunnelOperStatus,
mplsTunnelRowStatus,
mplsTunnelTrapEnable,
mplsTunnelStorageType,
mplsTunnelConfigured,
mplsTunnelActive,
mplsTunnelPrimaryInstance,
mplsTunnelPrimaryTimeUp,
mplsTunnelPathChanges,
mplsTunnelLastPathChange,
mplsTunnelCreationTime,
mplsTunnelStateTransitions,
mplsTunnelIncludeAnyAffinity,
mplsTunnelIncludeAllAffinity,
mplsTunnelExcludeAllAffinity,
mplsTunnelPerfPackets,
mplsTunnelPerfHCPackets,
mplsTunnelPerfErrors,
mplsTunnelPerfBytes,
mplsTunnelPerfHCBytes,
mplsTunnelResourcePointer,
mplsTunnelInstancePriority,
mplsTunnelPathInUse,
mplsTunnelRole,
mplsTunnelTotalUpTime,
mplsTunnelInstanceUpTime
}
STATUS current
DESCRIPTION
"Necessary, but not sufficient, set of objects to
implement tunnels. In addition, depending on the
type of the tunnels supported (for example,
manually configured or signaled, persistent or non-
persistent, etc.), the following other groups
defined below are mandatory: mplsTunnelManualGroup
and/or mplsTunnelSignaledGroup,
mplsTunnelIsNotIntfcGroup and/or
mplsTunnelIsIntfcGroup."
::= { mplsTeGroups 1 }
mplsTunnelManualGroup OBJECT-GROUP
OBJECTS { mplsTunnelSignallingProto }
STATUS current
DESCRIPTION
"Object(s) needed to implement manually configured
tunnels."
::= { mplsTeGroups 2 }
mplsTunnelSignaledGroup OBJECT-GROUP
OBJECTS {
mplsTunnelSetupPrio,
mplsTunnelHoldingPrio,
mplsTunnelSignallingProto,
mplsTunnelLocalProtectInUse,
mplsTunnelSessionAttributes,
mplsTunnelHopListIndexNext,
mplsTunnelHopAddrType,
mplsTunnelHopIpv4Addr,
mplsTunnelHopIpv4PrefixLen,
mplsTunnelHopIpv6Addr,
mplsTunnelHopIpv6PrefixLen,
mplsTunnelHopAsNumber,
mplsTunnelHopLspId,
mplsTunnelHopType,
mplsTunnelHopIncludeExclude,
mplsTunnelHopPathOptionName,
mplsTunnelHopEntryPathComp,
mplsTunnelHopRowStatus,
mplsTunnelHopStorageType
}
STATUS current
DESCRIPTION
"Object needed to implement signaled tunnels."
::= { mplsTeGroups 3 }
mplsTunnelScalarGroup OBJECT-GROUP
OBJECTS {
mplsTunnelConfigured,
mplsTunnelActive,
mplsTunnelTEDistProto,
mplsTunnelMaxHops
}
STATUS current
DESCRIPTION
"Scalar object needed to implement MPLS tunnels."
::= { mplsTeGroups 4 }
mplsTunnelIsIntfcGroup OBJECT-GROUP
OBJECTS { mplsTunnelIsIf }
STATUS current
DESCRIPTION
"Objects needed to implement tunnels that are
interfaces."
::= { mplsTeGroups 5 }
mplsTunnelIsNotIntfcGroup OBJECT-GROUP
OBJECTS { mplsTunnelIsIf }
STATUS current
DESCRIPTION
"Objects needed to implement tunnels that are not
interfaces."
::= { mplsTeGroups 6 }
mplsTunnelOptionalGroup OBJECT-GROUP
OBJECTS {
mplsTunnelResourceIndexNext,
mplsTunnelResourceMaxRate,
mplsTunnelResourceMeanRate,
mplsTunnelResourceMaxBurstSize,
mplsTunnelResourceMeanBurstSize,
mplsTunnelResourceExcessBurstSize,
mplsTunnelResourceFrequency,
mplsTunnelResourceWeight,
mplsTunnelResourceRowStatus,
mplsTunnelResourceStorageType,
mplsTunnelARHopAddrType,
mplsTunnelARHopIpv4Addr,
mplsTunnelARHopIpv4PrefixLen,
mplsTunnelARHopIpv6Addr,
mplsTunnelARHopIpv6PrefixLen,
mplsTunnelARHopAsNumber,
mplsTunnelARHopLspId,
mplsTunnelCHopAddrType,
mplsTunnelCHopIpv4Addr,
mplsTunnelCHopIpv4PrefixLen,
mplsTunnelCHopIpv6Addr,
mplsTunnelCHopIpv6PrefixLen,
mplsTunnelCHopAsNumber,
mplsTunnelCHopLspId,
mplsTunnelCHopType
}
STATUS current
DESCRIPTION
"The objects in this group are optional."
::= { mplsTeGroups 7 }
mplsTunnelCRLDPResOptionalGroup OBJECT-GROUP
OBJECTS {
mplsTunnelCRLDPResMeanBurstSize,
mplsTunnelCRLDPResExcessBurstSize,
mplsTunnelCRLDPResFrequency,
mplsTunnelCRLDPResWeight,
mplsTunnelCRLDPResFlags,
mplsTunnelCRLDPResRowStatus,
mplsTunnelCRLDPResStorageType
}
STATUS current
DESCRIPTION
"Set of objects implemented for resources applicable
for tunnels signaled using CR-LDP."
::= { mplsTeGroups 8 }
mplsTeNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
mplsTunnelUp,
mplsTunnelDown,
mplsTunnelRerouted,
mplsTunnelReoptimized
}
STATUS current
DESCRIPTION
"Set of notifications implemented in this module.
None is mandatory."
::= { mplsTeGroups 9 }
END
|