summaryrefslogtreecommitdiff
path: root/MIBS/hp/HP-ICF-INST-MON
blob: ac6f388394162fe3803629740b9c76187da8e024 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
HP-ICF-INST-MON DEFINITIONS ::= BEGIN

IMPORTS
    OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Integer32
        FROM SNMPv2-SMI
    MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
        FROM SNMPv2-CONF
    TruthValue, DisplayString
        FROM SNMPv2-TC
    InterfaceIndexOrZero
        FROM IF-MIB
    hpSwitch
        FROM HP-ICF-OID;

hpicfInstMonMIB MODULE-IDENTITY
    LAST-UPDATED "200601230000Z"
    ORGANIZATION "Hewlett-Packard Company
                  ProCurve Networking Business"
    CONTACT-INFO "Hewlett-Packard Company
                  8000 Foothills Blvd.
                  Roseville, CA 95747"
    DESCRIPTION  "This MIB module contains HP proprietary
                  definitions for Instrumentation Monitor."

    REVISION     "200601230000Z"
    DESCRIPTION  "Initial revision."

    ::= { hpSwitch 35 }

-- **********************************************************************
-- The Instrumentation Monitor MIB Groups
-- **********************************************************************

hpicfInstMonObjects OBJECT IDENTIFIER
    ::= { hpicfInstMonMIB 1 }

hpicfInstMonConformance OBJECT IDENTIFIER
    ::= { hpicfInstMonMIB 2 }

hpicfInstMonGroups OBJECT IDENTIFIER
    ::= { hpicfInstMonConformance 1 }

hpicfInstMonCompliances OBJECT IDENTIFIER
    ::= { hpicfInstMonConformance 2 }

-- **********************************************************************
-- Start of MIB objects
-- **********************************************************************

hpicfInstMonLogEnable OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "The operational status of the Instrumentation Monitor
                 on this switch."
    DEFVAL      { false }
    ::= { hpicfInstMonObjects 1 }

hpicfInstMonTrapEnable OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "The operational status of the Monitor notifications
                 on this switch."
    DEFVAL      { true }
    ::= { hpicfInstMonObjects 2 }

-- Start of hpicfInstMonParameterTable **********************************

hpicfInstMonParameterTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF HpicfInstMonParameterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Configuration of monitored instrumentation parameters."
    ::= { hpicfInstMonObjects 3 }

hpicfInstMonParameterEntry OBJECT-TYPE
    SYNTAX      HpicfInstMonParameterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "An entry in the hpicfInstMonParameterTable."
    INDEX       { hpicfInstMonInterfaceIndex,
                  hpicfInstMonParameterIndex }
    ::= { hpicfInstMonParameterTable 1 }

HpicfInstMonParameterEntry ::= SEQUENCE {
    hpicfInstMonInterfaceIndex     InterfaceIndexOrZero,
    hpicfInstMonParameterIndex     INTEGER,
    hpicfInstMonParameterName      DisplayString,
    hpicfInstMonParameterThreshold Integer32 }

hpicfInstMonInterfaceIndex OBJECT-TYPE
    SYNTAX      InterfaceIndexOrZero
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "0 for global parameters, port number for per-port
                 parameters."
    ::= { hpicfInstMonParameterEntry 1 }

hpicfInstMonParameterIndex OBJECT-TYPE
    SYNTAX      INTEGER( 1..'FFFF'h )
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "The index of the parameter."
    ::= { hpicfInstMonParameterEntry 2 }

hpicfInstMonParameterName OBJECT-TYPE
    SYNTAX      DisplayString( SIZE( 0..20 ) )
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "The name of the parameter."
    ::= { hpicfInstMonParameterEntry 3 }

hpicfInstMonParameterThreshold OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "Generate notification if the limit is not 0 and
                 parameter value is beyond this limit."
    ::= { hpicfInstMonParameterEntry 4 }

-- End of hpicfInstMonParameterTable ************************************

hpicfInstMonNotificationText OBJECT-TYPE
    SYNTAX      DisplayString( SIZE( 0..255 ) )
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "This string is sent with hpicfInstMonNotification."
    ::= { hpicfInstMonObjects 4 }

hpicfInstMonNotification NOTIFICATION-TYPE
    OBJECTS     { hpicfInstMonNotificationText }
    STATUS      current
    DESCRIPTION "This notification is generated when the monitored
                 parameter is beyond the configured threshold value."
    ::= { hpicfInstMonObjects 5 }

-- **********************************************************************
-- Conformance Information
-- **********************************************************************

hpicfInstMonNotificationGroup NOTIFICATION-GROUP
    NOTIFICATIONS { hpicfInstMonNotification }
    STATUS      current
    DESCRIPTION "This notification is generated by Monitor when
                 parameter is beyond its threshold limit."
    ::= { hpicfInstMonGroups 1 }

hpicfInstMonBaseGroup OBJECT-GROUP
    OBJECTS   { hpicfInstMonLogEnable,
                hpicfInstMonTrapEnable,
                hpicfInstMonInterfaceIndex,
                hpicfInstMonParameterIndex,
                hpicfInstMonParameterName,
                hpicfInstMonParameterThreshold }
    STATUS      current
    DESCRIPTION "A collection of objects to support basic Instrumentation
                 Monitor configuration on ProCurve switches."
    ::= { hpicfInstMonGroups 2 }

-- **********************************************************************
-- Compliance statements
-- **********************************************************************

hpicfInstMonBaseCompliance MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION "The compliance statement for ProCurve switches running
                 Instrumentation Monitor and implementing the
                 HP-ICF-INST-MON MIB."
    MODULE  -- this module
    MANDATORY-GROUPS { hpicfInstMonBaseGroup }
    ::= { hpicfInstMonCompliances 1 }