1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
|
-- **********************************************************************
-- HILLSTONE-SYSTEM-MIB
--
-- Copyright (c) 2009 by Hillstone Networks, Inc.
-- All rights reserved.
--
-- Version: V3
-- Description: Hillstone Networks SYSTEM MIB Object Identifier Assignments
-- **********************************************************************
--
HILLSTONE-SYSTEM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY FROM SNMPv2-SMI
NetworkAddress, IpAddress,
Counter, Gauge, TimeTicks FROM RFC1155-SMI
TruthValue FROM SNMPv2-TC
hillstoneSys FROM HILLSTONE-SMI;
-- textual conventions
DisplayString ::=
OCTET STRING
-- This data type is used to model textual information taken
-- from the NVT ASCII character set. By convention, objects
-- with this syntax are declared as having
--
-- SIZE (0..255)
hillstoneSysMibObjects OBJECT IDENTIFIER ::= { hillstoneSys 1 }
-- hillstone systems
sysSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
::= { hillstoneSysMibObjects 1 }
sysSoftware OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
::= { hillstoneSysMibObjects 2 }
sysCPU OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
::= { hillstoneSysMibObjects 3 }
sysTotalMemory OBJECT-TYPE
SYNTAX Gauge32
ACCESS read-only
STATUS mandatory
::= { hillstoneSysMibObjects 4 }
sysCurMemory OBJECT-TYPE
SYNTAX Gauge32
ACCESS read-only
STATUS mandatory
::= { hillstoneSysMibObjects 5 }
sysTotalSession OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
::= { hillstoneSysMibObjects 6 }
sysCurSession OBJECT-TYPE
SYNTAX Gauge32
ACCESS read-only
STATUS mandatory
::= { hillstoneSysMibObjects 7 }
sysHAStatus OBJECT-TYPE
SYNTAX INTEGER
{
none (0),
init (1),
hello (2),
backup (3),
master (4),
slase (5),
AA-mode (6)
}
ACCESS read-only
STATUS mandatory
::= { hillstoneSysMibObjects 8 }
sysSnmpStackStatus OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS current
DESCRIPTION
"The running status of snmp Stack."
::= { hillstoneSysMibObjects 9 }
sysTr069StackStatus OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS current
DESCRIPTION
"The running status of tr069 stack."
::= { hillstoneSysMibObjects 10 }
sysVedorOUI OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"The oui code of the Tr069 stack.."
::= { hillstoneSysMibObjects 11 }
sysLogStackStatus OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS current
DESCRIPTION
"The running status of syslog stack."
::= { hillstoneSysMibObjects 12 }
sysLogServerAddress1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"The syslog receiver addrees 1."
::= { hillstoneSysMibObjects 13 }
sysLogServerAddress2 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"The syslog receiver addrees 2."
::= { hillstoneSysMibObjects 14 }
sysDeviceReloadAction OBJECT-TYPE
SYNTAX INTEGER
{
reloadUnAvailable(1),
reloadAtOnce(2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"The actioin of reloading the device. when the value is set to 2,the device will reboot at once."
::= { hillstoneSysMibObjects 15 }
sysStatisticsPeriod OBJECT-TYPE
SYNTAX INTEGER
{
oneDay(1)
}
ACCESS read-only
STATUS current
DESCRIPTION
"The period of statistics. default statistics period is 24hours"
::= { hillstoneSysMibObjects 16 }
END
|