1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
|
GEIST-V4-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString FROM SNMPv2-TC
MODULE-IDENTITY, OBJECT-TYPE, IpAddress, enterprises, Integer32, Gauge32, NOTIFICATION-TYPE FROM SNMPv2-SMI;
geist MODULE-IDENTITY
LAST-UPDATED "201209110000Z"
ORGANIZATION "Geist"
CONTACT-INFO "support@geistglobal.com"
DESCRIPTION "The MIB for Geist Products"
REVISION "201209110000Z"
DESCRIPTION "Original version"
::= { enterprises 21239 }
blackbird OBJECT IDENTIFIER
::= { geist 5 }
watchdog100 OBJECT IDENTIFIER
::= { blackbird 1 }
--###########################################################################################--
--deviceInfo--
--###########################################################################################--
deviceInfo OBJECT IDENTIFIER
::= { watchdog100 1 }
productTitle OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Product name"
::= { deviceInfo 1 }
productVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Product version"
::= { deviceInfo 2 }
productFriendlyName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "User-assigned name"
::= { deviceInfo 3 }
productMacAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Product's unique MAC address"
::= { deviceInfo 4 }
productUrl OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Product's main URL access point"
::= { deviceInfo 5 }
deviceCount OBJECT-TYPE
SYNTAX Integer32(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total number of devices on unit"
::= { deviceInfo 6 }
temperatureUnits OBJECT-TYPE
SYNTAX Integer32(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Current units for temperature values. 0 = Degrees Fahrenheit, 1 = Degrees Celsius"
::= { deviceInfo 7 }
--###########################################################################################--
--internalTable--
--###########################################################################################--
internalTable OBJECT-TYPE
SYNTAX SEQUENCE OF InternalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Internal sensors for units"
::= { watchdog100 2 }
internalEntry OBJECT-TYPE
SYNTAX InternalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry in the internalTable table: each entry contains an index and other sensor details"
INDEX { internalIndex }
::= { internalTable 1 }
InternalEntry ::= SEQUENCE {
internalIndex Integer32,
internalSerial DisplayString,
internalName DisplayString,
internalAvail Gauge32,
internalTemp Integer32,
internalHumidity Integer32,
internalDewPoint Integer32
}
internalIndex OBJECT-TYPE
SYNTAX Integer32(1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Table entry index value"
::= { internalEntry 1 }
internalSerial OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial Number"
::= { internalEntry 2 }
internalName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Friendly Name"
::= { internalEntry 3 }
internalAvail OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable"
::= { internalEntry 4 }
internalTemp OBJECT-TYPE
SYNTAX Integer32(-40..200)
UNITS "0.1 Degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo"
::= { internalEntry 5 }
internalHumidity OBJECT-TYPE
SYNTAX Integer32(0..100)
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Humidity reading"
::= { internalEntry 6 }
internalDewPoint OBJECT-TYPE
SYNTAX Integer32(-40..200)
UNITS "0.1 Degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current reading for Dew-point in tenths of degrees. Units are given by temperatureUnits field in deviceInfo"
::= { internalEntry 7 }
--###########################################################################################--
--tempSensorTable--
--###########################################################################################--
tempSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF TempSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Remote Temperature Sensor"
::= { watchdog100 4 }
tempSensorEntry OBJECT-TYPE
SYNTAX TempSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry in the tempSensorTable table: each entry contains an index and other sensor details"
INDEX { tempSensorIndex }
::= { tempSensorTable 1 }
TempSensorEntry ::= SEQUENCE {
tempSensorIndex Integer32,
tempSensorSerial DisplayString,
tempSensorName DisplayString,
tempSensorAvail Gauge32,
tempSensorTemp Integer32
}
tempSensorIndex OBJECT-TYPE
SYNTAX Integer32(1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Table entry index value"
::= { tempSensorEntry 1 }
tempSensorSerial OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial Number"
::= { tempSensorEntry 2 }
tempSensorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Friendly Name"
::= { tempSensorEntry 3 }
tempSensorAvail OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable"
::= { tempSensorEntry 4 }
tempSensorTemp OBJECT-TYPE
SYNTAX Integer32(-40..200)
UNITS "0.1 Degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo"
::= { tempSensorEntry 5 }
--###########################################################################################--
--airFlowSensorTable--
--###########################################################################################--
airFlowSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF AirFlowSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Remote Airflow, Humidity, Temperature and Dewpoint Sensor "
::= { watchdog100 5 }
airFlowSensorEntry OBJECT-TYPE
SYNTAX AirFlowSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry in the airFlowSensorTable table: each entry contains an index and other sensor details"
INDEX { airFlowSensorIndex }
::= { airFlowSensorTable 1 }
AirFlowSensorEntry ::= SEQUENCE {
airFlowSensorIndex Integer32,
airFlowSensorSerial DisplayString,
airFlowSensorName DisplayString,
airFlowSensorAvail Gauge32,
airFlowSensorTemp Integer32,
airFlowSensorFlow Integer32,
airFlowSensorHumidity Integer32,
airFlowSensorDewPoint Integer32
}
airFlowSensorIndex OBJECT-TYPE
SYNTAX Integer32(1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Table entry index value"
::= { airFlowSensorEntry 1 }
airFlowSensorSerial OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial Number"
::= { airFlowSensorEntry 2 }
airFlowSensorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Friendly Name"
::= { airFlowSensorEntry 3 }
airFlowSensorAvail OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable"
::= { airFlowSensorEntry 4 }
airFlowSensorTemp OBJECT-TYPE
SYNTAX Integer32(-40..200)
UNITS "0.1 Degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo"
::= { airFlowSensorEntry 5 }
airFlowSensorFlow OBJECT-TYPE
SYNTAX Integer32(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "AFHT3 Airflow reading"
::= { airFlowSensorEntry 6 }
airFlowSensorHumidity OBJECT-TYPE
SYNTAX Integer32(0..100)
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "AFHT3 Humidity reading"
::= { airFlowSensorEntry 7 }
airFlowSensorDewPoint OBJECT-TYPE
SYNTAX Integer32(-40..200)
UNITS "0.1 Degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current reading for Dew Point in tenths of degrees. Units are given by temperatureUnits field in deviceInfo"
::= { airFlowSensorEntry 8 }
--###########################################################################################--
--dewPointSensorTable--
--###########################################################################################--
dewPointSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF DewPointSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Remote Dew Point sensor"
::= { watchdog100 6 }
dewPointSensorEntry OBJECT-TYPE
SYNTAX DewPointSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry in the dewPointSensorTable table: each entry contains an index and other sensor details"
INDEX { dewPointSensorIndex }
::= { dewPointSensorTable 1 }
DewPointSensorEntry ::= SEQUENCE {
dewPointSensorIndex Integer32,
dewPointSensorSerial DisplayString,
dewPointSensorName DisplayString,
dewPointSensorAvail Gauge32,
dewPointSensorTemp Integer32,
dewPointSensorHumidity Integer32,
dewPointSensorDewPoint Integer32
}
dewPointSensorIndex OBJECT-TYPE
SYNTAX Integer32(1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Table entry index value"
::= { dewPointSensorEntry 1 }
dewPointSensorSerial OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial Number"
::= { dewPointSensorEntry 2 }
dewPointSensorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Friendly Name"
::= { dewPointSensorEntry 3 }
dewPointSensorAvail OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable"
::= { dewPointSensorEntry 4 }
dewPointSensorTemp OBJECT-TYPE
SYNTAX Integer32(-40..200)
UNITS "0.1 Degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo"
::= { dewPointSensorEntry 5 }
dewPointSensorHumidity OBJECT-TYPE
SYNTAX Integer32(0..100)
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Humidity reading"
::= { dewPointSensorEntry 6 }
dewPointSensorDewPoint OBJECT-TYPE
SYNTAX Integer32(-40..200)
UNITS "0.1 Degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current reading for Dew-point in tenths of degrees. Units are given by temperatureUnits field in deviceInfo"
::= { dewPointSensorEntry 7 }
--###########################################################################################--
--ccatSensorTable--
--###########################################################################################--
ccatSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF CcatSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Remote CCAT sensor"
::= { watchdog100 7 }
ccatSensorEntry OBJECT-TYPE
SYNTAX CcatSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry in the ccatSensorTable table: each entry contains an index and other sensor details"
INDEX { ccatSensorIndex }
::= { ccatSensorTable 1 }
CcatSensorEntry ::= SEQUENCE {
ccatSensorIndex Integer32,
ccatSensorSerial DisplayString,
ccatSensorName DisplayString,
ccatSensorAvail Gauge32,
ccatSensorValue Integer32,
ccatSensorType DisplayString,
ccatSensorDescription DisplayString
}
ccatSensorIndex OBJECT-TYPE
SYNTAX Integer32(1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Table entry index value"
::= { ccatSensorEntry 1 }
ccatSensorSerial OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial Number"
::= { ccatSensorEntry 2 }
ccatSensorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Friendly Name"
::= { ccatSensorEntry 3 }
ccatSensorAvail OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable"
::= { ccatSensorEntry 4 }
ccatSensorValue OBJECT-TYPE
SYNTAX Integer32(-100..5000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "CCAT sensor reading"
::= { ccatSensorEntry 5 }
ccatSensorType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "CCAT sensor type"
::= { ccatSensorEntry 6 }
ccatSensorDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "CCAT sensor value description"
::= { ccatSensorEntry 7 }
--###########################################################################################--
--t3hdSensorTable--
--###########################################################################################--
t3hdSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF T3hdSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Remote Temperature x 3, Humidity and Dewpoint Sensor"
::= { watchdog100 8 }
t3hdSensorEntry OBJECT-TYPE
SYNTAX T3hdSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry in the t3hdSensorTable table: each entry contains an index and other sensor details"
INDEX { t3hdSensorIndex }
::= { t3hdSensorTable 1 }
T3hdSensorEntry ::= SEQUENCE {
t3hdSensorIndex Integer32,
t3hdSensorSerial DisplayString,
t3hdSensorName DisplayString,
t3hdSensorAvail Gauge32,
t3hdSensorIntName DisplayString,
t3hdSensorIntTemp Integer32,
t3hdSensorIntHumidity Integer32,
t3hdSensorIntDewPoint Integer32,
t3hdSensorExtAAvail Gauge32,
t3hdSensorExtAName DisplayString,
t3hdSensorExtATemp Integer32,
t3hdSensorExtBAvail Gauge32,
t3hdSensorExtBName DisplayString,
t3hdSensorExtBTemp Integer32
}
t3hdSensorIndex OBJECT-TYPE
SYNTAX Integer32(1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Table entry index value"
::= { t3hdSensorEntry 1 }
t3hdSensorSerial OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial Number"
::= { t3hdSensorEntry 2 }
t3hdSensorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Friendly Name"
::= { t3hdSensorEntry 3 }
t3hdSensorAvail OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable"
::= { t3hdSensorEntry 4 }
t3hdSensorIntName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "T3HD Sensor Internal Friendly Name"
::= { t3hdSensorEntry 5 }
t3hdSensorIntTemp OBJECT-TYPE
SYNTAX Integer32(-40..200)
UNITS "0.1 Degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current reading for Internal Temperature in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo"
::= { t3hdSensorEntry 6 }
t3hdSensorIntHumidity OBJECT-TYPE
SYNTAX Integer32(0..100)
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "T3HD Sensor Internal Humidity"
::= { t3hdSensorEntry 7 }
t3hdSensorIntDewPoint OBJECT-TYPE
SYNTAX Integer32(-40..200)
UNITS "0.1 Degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current reading for Internal DewPoint in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo"
::= { t3hdSensorEntry 8 }
t3hdSensorExtAAvail OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "T3HD External A status: 0 = Unavailable, 1 = Available"
::= { t3hdSensorEntry 9 }
t3hdSensorExtAName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "T3HD External A Friendly Name"
::= { t3hdSensorEntry 10 }
t3hdSensorExtATemp OBJECT-TYPE
SYNTAX Integer32(-40..200)
UNITS "0.1 Degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current reading for External Temperature A in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo"
::= { t3hdSensorEntry 11 }
t3hdSensorExtBAvail OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "T3HD External B status: 0 = Unavailable, 1 = Available"
::= { t3hdSensorEntry 12 }
t3hdSensorExtBName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "T3HD External B Friendly Name"
::= { t3hdSensorEntry 13 }
t3hdSensorExtBTemp OBJECT-TYPE
SYNTAX Integer32(-40..200)
UNITS "0.1 Degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current reading for External Temperature B in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo"
::= { t3hdSensorEntry 14 }
--###########################################################################################--
--thdSensorTable--
--###########################################################################################--
thdSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF ThdSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Remote Temperature, Humidity and Dewpoint Sensor"
::= { watchdog100 9 }
thdSensorEntry OBJECT-TYPE
SYNTAX ThdSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry in the thdSensorTable table: each entry contains an index and other sensor details"
INDEX { thdSensorIndex }
::= { thdSensorTable 1 }
ThdSensorEntry ::= SEQUENCE {
thdSensorIndex Integer32,
thdSensorSerial DisplayString,
thdSensorName DisplayString,
thdSensorAvail Gauge32,
thdSensorTemp Integer32,
thdSensorHumidity Integer32,
thdSensorDewPoint Integer32
}
thdSensorIndex OBJECT-TYPE
SYNTAX Integer32(1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Table entry index value"
::= { thdSensorEntry 1 }
thdSensorSerial OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial Number"
::= { thdSensorEntry 2 }
thdSensorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Friendly Name"
::= { thdSensorEntry 3 }
thdSensorAvail OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable"
::= { thdSensorEntry 4 }
thdSensorTemp OBJECT-TYPE
SYNTAX Integer32(-40..200)
UNITS "0.1 Degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current reading for Temperature in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo"
::= { thdSensorEntry 5 }
thdSensorHumidity OBJECT-TYPE
SYNTAX Integer32(0..100)
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "THD Sensor Humidity"
::= { thdSensorEntry 6 }
thdSensorDewPoint OBJECT-TYPE
SYNTAX Integer32(-40..200)
UNITS "0.1 Degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current reading for DewPoint in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo"
::= { thdSensorEntry 7 }
--###########################################################################################--
--rpmSensorTable--
--###########################################################################################--
rpmSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpmSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Remote Power Manager Sensor"
::= { watchdog100 10 }
rpmSensorEntry OBJECT-TYPE
SYNTAX RpmSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry in the rpmSensorTable table: each entry contains an index and other sensor details"
INDEX { rpmSensorIndex }
::= { rpmSensorTable 1 }
RpmSensorEntry ::= SEQUENCE {
rpmSensorIndex Integer32,
rpmSensorSerial DisplayString,
rpmSensorName DisplayString,
rpmSensorAvail Gauge32,
rpmSensorEnergy Gauge32,
rpmSensorVoltage Gauge32,
rpmSensorVoltageMax Gauge32,
rpmSensorVoltageMin Gauge32,
rpmSensorVoltagePeak Gauge32,
rpmSensorCurrent Gauge32,
rpmSensorRealPower Gauge32,
rpmSensorApparentPower Gauge32,
rpmSensorPowerFactor Gauge32,
rpmSensorOutlet1 Gauge32,
rpmSensorOutlet2 Gauge32
}
rpmSensorIndex OBJECT-TYPE
SYNTAX Integer32(1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Table entry index value"
::= { rpmSensorEntry 1 }
rpmSensorSerial OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial Number"
::= { rpmSensorEntry 2 }
rpmSensorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Friendly Name"
::= { rpmSensorEntry 3 }
rpmSensorAvail OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable"
::= { rpmSensorEntry 4 }
rpmSensorEnergy OBJECT-TYPE
SYNTAX Gauge32
UNITS "kWh"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RPM Sensor Accumulated Energy"
::= { rpmSensorEntry 5 }
rpmSensorVoltage OBJECT-TYPE
SYNTAX Gauge32
UNITS "Volts (rms)"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RPM Sensor Voltage"
::= { rpmSensorEntry 6 }
rpmSensorVoltageMax OBJECT-TYPE
SYNTAX Gauge32
UNITS "Volts (rms)"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RPM Sensor Voltage (Max)"
::= { rpmSensorEntry 7 }
rpmSensorVoltageMin OBJECT-TYPE
SYNTAX Gauge32
UNITS "Volts (rms)"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RPM Sensor Voltage (Min)"
::= { rpmSensorEntry 8 }
rpmSensorVoltagePeak OBJECT-TYPE
SYNTAX Gauge32
UNITS "Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RPM Sensor Voltage (Peak)"
::= { rpmSensorEntry 9 }
rpmSensorCurrent OBJECT-TYPE
SYNTAX Gauge32
UNITS "0.1 Amps (rms)"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RPM Sensor Current reading in deciAmps"
::= { rpmSensorEntry 10 }
rpmSensorRealPower OBJECT-TYPE
SYNTAX Gauge32
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RPM Sensor Real Power"
::= { rpmSensorEntry 11 }
rpmSensorApparentPower OBJECT-TYPE
SYNTAX Gauge32
UNITS "Volt-Amps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RPM Sensor Apparent Power"
::= { rpmSensorEntry 12 }
rpmSensorPowerFactor OBJECT-TYPE
SYNTAX Gauge32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RPM Sensor Power Factor"
::= { rpmSensorEntry 13 }
rpmSensorOutlet1 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RPM Sensor Outlet 1 State: 0 = off, 1 = on"
::= { rpmSensorEntry 14 }
rpmSensorOutlet2 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RPM Sensor Outlet 2 State: 0 = off, 1 = on"
::= { rpmSensorEntry 15 }
--###########################################################################################--
--a2dSensorTable--
--###########################################################################################--
a2dSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF A2DSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Analog Measurement Sensor (Voltage, Current, or Dry Contact)"
::= { watchdog100 11 }
a2DSensorEntry OBJECT-TYPE
SYNTAX A2DSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry in the a2dSensorTable table: each entry contains an index and other sensor details"
INDEX { a2dSensorIndex }
::= { a2dSensorTable 1 }
A2DSensorEntry ::= SEQUENCE {
a2dSensorIndex Integer32,
a2dSensorSerial DisplayString,
a2dSensorName DisplayString,
a2dSensorAvail Gauge32,
a2dSensorValue Integer32
}
a2dSensorIndex OBJECT-TYPE
SYNTAX Integer32(1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Table entry index value"
::= { a2DSensorEntry 1 }
a2dSensorSerial OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial Number"
::= { a2DSensorEntry 2 }
a2dSensorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Friendly Name"
::= { a2DSensorEntry 3 }
a2dSensorAvail OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable"
::= { a2DSensorEntry 4 }
a2dSensorValue OBJECT-TYPE
SYNTAX Integer32(-1000000..1000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current analog measurement reading within either a user defined or preset range depending on device mode."
::= { a2DSensorEntry 5 }
--###########################################################################################--
--Notifications--
--###########################################################################################--
trap OBJECT IDENTIFIER ::= { watchdog100 32767 }
trapPrefix OBJECT IDENTIFIER ::= { trap 0 }
internalTestNOTIFY NOTIFICATION-TYPE
STATUS current
DESCRIPTION "Test SNMP Trap"
::= { trapPrefix 10101 }
--#####deviceInfo#####--
--#####internalTable#####--
internalAvailNOTIFY NOTIFICATION-TYPE
OBJECTS { internalAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap"
::= { trapPrefix 10204 }
internalAvailCLEAR NOTIFICATION-TYPE
OBJECTS { internalAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap"
::= { trapPrefix 20204 }
internalTempNOTIFY NOTIFICATION-TYPE
OBJECTS { internalTemp, temperatureUnits }
STATUS current
DESCRIPTION "Internal Temperature Sensor Trap"
::= { trapPrefix 10205 }
internalTempCLEAR NOTIFICATION-TYPE
OBJECTS { internalTemp, temperatureUnits }
STATUS current
DESCRIPTION "Internal Temperature Sensor Clear Trap"
::= { trapPrefix 20205 }
internalHumidityNOTIFY NOTIFICATION-TYPE
OBJECTS { internalHumidity }
STATUS current
DESCRIPTION "Humidity reading Trap"
::= { trapPrefix 10206 }
internalHumidityCLEAR NOTIFICATION-TYPE
OBJECTS { internalHumidity }
STATUS current
DESCRIPTION "Humidity reading Clear Trap"
::= { trapPrefix 20206 }
internalDewPointNOTIFY NOTIFICATION-TYPE
OBJECTS { internalDewPoint, temperatureUnits }
STATUS current
DESCRIPTION "Internal Dew Point Sensor Trap"
::= { trapPrefix 10207 }
internalDewPointCLEAR NOTIFICATION-TYPE
OBJECTS { internalDewPoint, temperatureUnits }
STATUS current
DESCRIPTION "Internal Dew Point Sensor Clear Trap"
::= { trapPrefix 20207 }
--#####tempSensorTable#####--
tempSensorAvailNOTIFY NOTIFICATION-TYPE
OBJECTS { tempSensorAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap"
::= { trapPrefix 10404 }
tempSensorAvailCLEAR NOTIFICATION-TYPE
OBJECTS { tempSensorAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap"
::= { trapPrefix 20404 }
tempSensorTempNOTIFY NOTIFICATION-TYPE
OBJECTS { tempSensorTemp, temperatureUnits }
STATUS current
DESCRIPTION "Remote Temperature Sensor Trap"
::= { trapPrefix 10405 }
tempSensorTempCLEAR NOTIFICATION-TYPE
OBJECTS { tempSensorTemp, temperatureUnits }
STATUS current
DESCRIPTION "Remote Temperature Sensor Clear Trap"
::= { trapPrefix 20405 }
--#####airFlowSensorTable#####--
airFlowSensorAvailNOTIFY NOTIFICATION-TYPE
OBJECTS { airFlowSensorAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap"
::= { trapPrefix 10504 }
airFlowSensorAvailCLEAR NOTIFICATION-TYPE
OBJECTS { airFlowSensorAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap"
::= { trapPrefix 20504 }
airFlowSensorTempNOTIFY NOTIFICATION-TYPE
OBJECTS { airFlowSensorTemp, temperatureUnits }
STATUS current
DESCRIPTION "AFHT3 Sensor Temperature Trap"
::= { trapPrefix 10505 }
airFlowSensorTempCLEAR NOTIFICATION-TYPE
OBJECTS { airFlowSensorTemp, temperatureUnits }
STATUS current
DESCRIPTION "AFHT3 Sensor Temperature Clear Trap"
::= { trapPrefix 20505 }
airFlowSensorFlowNOTIFY NOTIFICATION-TYPE
OBJECTS { airFlowSensorFlow }
STATUS current
DESCRIPTION "AFHT3 Airflow reading Trap"
::= { trapPrefix 10506 }
airFlowSensorFlowCLEAR NOTIFICATION-TYPE
OBJECTS { airFlowSensorFlow }
STATUS current
DESCRIPTION "AFHT3 Airflow reading Clear Trap"
::= { trapPrefix 20506 }
airFlowSensorHumidityNOTIFY NOTIFICATION-TYPE
OBJECTS { airFlowSensorHumidity }
STATUS current
DESCRIPTION "AFHT3 Humidity reading Trap"
::= { trapPrefix 10507 }
airFlowSensorHumidityCLEAR NOTIFICATION-TYPE
OBJECTS { airFlowSensorHumidity }
STATUS current
DESCRIPTION "AFHT3 Humidity reading Clear Trap"
::= { trapPrefix 20507 }
airFlowSensorDewPointNOTIFY NOTIFICATION-TYPE
OBJECTS { airFlowSensorDewPoint, temperatureUnits }
STATUS current
DESCRIPTION "AFHT3 Sensor Dew Point Trap"
::= { trapPrefix 10508 }
airFlowSensorDewPointCLEAR NOTIFICATION-TYPE
OBJECTS { airFlowSensorDewPoint, temperatureUnits }
STATUS current
DESCRIPTION "AFHT3 Sensor Dew Point Clear Trap"
::= { trapPrefix 20508 }
--#####dewPointSensorTable#####--
dewPointSensorAvailNOTIFY NOTIFICATION-TYPE
OBJECTS { dewPointSensorAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap"
::= { trapPrefix 10604 }
dewPointSensorAvailCLEAR NOTIFICATION-TYPE
OBJECTS { dewPointSensorAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap"
::= { trapPrefix 20604 }
dewPointSensorTempNOTIFY NOTIFICATION-TYPE
OBJECTS { dewPointSensorTemp, temperatureUnits }
STATUS current
DESCRIPTION "Remote Dew Point Sensor Temperature Trap"
::= { trapPrefix 10605 }
dewPointSensorTempCLEAR NOTIFICATION-TYPE
OBJECTS { dewPointSensorTemp, temperatureUnits }
STATUS current
DESCRIPTION "Remote Dew Point Sensor Temperature Clear Trap"
::= { trapPrefix 20605 }
dewPointSensorHumidityNOTIFY NOTIFICATION-TYPE
OBJECTS { dewPointSensorHumidity }
STATUS current
DESCRIPTION "Humidity reading Trap"
::= { trapPrefix 10606 }
dewPointSensorHumidityCLEAR NOTIFICATION-TYPE
OBJECTS { dewPointSensorHumidity }
STATUS current
DESCRIPTION "Humidity reading Clear Trap"
::= { trapPrefix 20606 }
dewPointSensorDewPointNOTIFY NOTIFICATION-TYPE
OBJECTS { dewPointSensorDewPoint, temperatureUnits }
STATUS current
DESCRIPTION "Remote Dew Point Sensor Dew Point Trap"
::= { trapPrefix 10607 }
dewPointSensorDewPointCLEAR NOTIFICATION-TYPE
OBJECTS { dewPointSensorDewPoint, temperatureUnits }
STATUS current
DESCRIPTION "Remote Dew Point Sensor Dew Point Clear Trap"
::= { trapPrefix 20607 }
--#####ccatSensorTable#####--
ccatSensorAvailNOTIFY NOTIFICATION-TYPE
OBJECTS { ccatSensorAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap"
::= { trapPrefix 10704 }
ccatSensorAvailCLEAR NOTIFICATION-TYPE
OBJECTS { ccatSensorAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap"
::= { trapPrefix 20704 }
ccatSensorValueNOTIFY NOTIFICATION-TYPE
OBJECTS { ccatSensorValue, ccatSensorType }
STATUS current
DESCRIPTION "CCAT sensor reading Trap"
::= { trapPrefix 10705 }
ccatSensorValueCLEAR NOTIFICATION-TYPE
OBJECTS { ccatSensorValue, ccatSensorType }
STATUS current
DESCRIPTION "CCAT sensor reading Clear Trap"
::= { trapPrefix 20705 }
--#####t3hdSensorTable#####--
t3hdSensorAvailNOTIFY NOTIFICATION-TYPE
OBJECTS { t3hdSensorAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap"
::= { trapPrefix 10804 }
t3hdSensorAvailCLEAR NOTIFICATION-TYPE
OBJECTS { t3hdSensorAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap"
::= { trapPrefix 20804 }
t3hdSensorIntTempNOTIFY NOTIFICATION-TYPE
OBJECTS { t3hdSensorIntTemp, temperatureUnits }
STATUS current
DESCRIPTION "T3HD Sensor Temperature Trap"
::= { trapPrefix 10806 }
t3hdSensorIntTempCLEAR NOTIFICATION-TYPE
OBJECTS { t3hdSensorIntTemp, temperatureUnits }
STATUS current
DESCRIPTION "T3HD Sensor Temperature Clear Trap"
::= { trapPrefix 20806 }
t3hdSensorIntHumidityNOTIFY NOTIFICATION-TYPE
OBJECTS { t3hdSensorIntHumidity }
STATUS current
DESCRIPTION "T3HD Sensor Internal Humidity Trap"
::= { trapPrefix 10807 }
t3hdSensorIntHumidityCLEAR NOTIFICATION-TYPE
OBJECTS { t3hdSensorIntHumidity }
STATUS current
DESCRIPTION "T3HD Sensor Internal Humidity Clear Trap"
::= { trapPrefix 20807 }
t3hdSensorIntDewPointNOTIFY NOTIFICATION-TYPE
OBJECTS { t3hdSensorIntDewPoint, temperatureUnits }
STATUS current
DESCRIPTION "T3HD Sensor Dew Point Trap"
::= { trapPrefix 10808 }
t3hdSensorIntDewPointCLEAR NOTIFICATION-TYPE
OBJECTS { t3hdSensorIntDewPoint, temperatureUnits }
STATUS current
DESCRIPTION "T3HD Sensor Dew Point Clear Trap"
::= { trapPrefix 20808 }
t3hdSensorExtATempNOTIFY NOTIFICATION-TYPE
OBJECTS { t3hdSensorExtATemp, temperatureUnits }
STATUS current
DESCRIPTION "T3HD Sensor External A Temperature Trap"
::= { trapPrefix 10811 }
t3hdSensorExtATempCLEAR NOTIFICATION-TYPE
OBJECTS { t3hdSensorExtATemp, temperatureUnits }
STATUS current
DESCRIPTION "T3HD Sensor External A Temperature Clear Trap"
::= { trapPrefix 20811 }
t3hdSensorExtBTempNOTIFY NOTIFICATION-TYPE
OBJECTS { t3hdSensorExtBTemp, temperatureUnits }
STATUS current
DESCRIPTION "T3HD Sensor External B Temperature Trap"
::= { trapPrefix 10814 }
t3hdSensorExtBTempCLEAR NOTIFICATION-TYPE
OBJECTS { t3hdSensorExtBTemp, temperatureUnits }
STATUS current
DESCRIPTION "T3HD Sensor External B Temperature Clear Trap"
::= { trapPrefix 20814 }
--#####thdSensorTable#####--
thdSensorAvailNOTIFY NOTIFICATION-TYPE
OBJECTS { thdSensorAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap"
::= { trapPrefix 10904 }
thdSensorAvailCLEAR NOTIFICATION-TYPE
OBJECTS { thdSensorAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap"
::= { trapPrefix 20904 }
thdSensorTempNOTIFY NOTIFICATION-TYPE
OBJECTS { thdSensorTemp, temperatureUnits }
STATUS current
DESCRIPTION "THD Sensor Temperature Trap"
::= { trapPrefix 10905 }
thdSensorTempCLEAR NOTIFICATION-TYPE
OBJECTS { thdSensorTemp, temperatureUnits }
STATUS current
DESCRIPTION "THD Sensor Temperature Clear Trap"
::= { trapPrefix 20905 }
thdSensorHumidityNOTIFY NOTIFICATION-TYPE
OBJECTS { thdSensorHumidity }
STATUS current
DESCRIPTION "THD Sensor Humidity Trap"
::= { trapPrefix 10906 }
thdSensorHumidityCLEAR NOTIFICATION-TYPE
OBJECTS { thdSensorHumidity }
STATUS current
DESCRIPTION "THD Sensor Humidity Clear Trap"
::= { trapPrefix 20906 }
thdSensorDewPointNOTIFY NOTIFICATION-TYPE
OBJECTS { thdSensorDewPoint, temperatureUnits }
STATUS current
DESCRIPTION "THD Sensor Dew Point Trap"
::= { trapPrefix 10907 }
thdSensorDewPointCLEAR NOTIFICATION-TYPE
OBJECTS { thdSensorDewPoint, temperatureUnits }
STATUS current
DESCRIPTION "THD Sensor Dew Point Clear Trap"
::= { trapPrefix 20907 }
--#####rpmSensorTable#####--
rpmSensorAvailNOTIFY NOTIFICATION-TYPE
OBJECTS { rpmSensorAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap"
::= { trapPrefix 11004 }
rpmSensorAvailCLEAR NOTIFICATION-TYPE
OBJECTS { rpmSensorAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap"
::= { trapPrefix 21004 }
rpmSensorEnergyNOTIFY NOTIFICATION-TYPE
OBJECTS { rpmSensorEnergy }
STATUS current
DESCRIPTION "RPM Sensor Accumulated Energy Trap"
::= { trapPrefix 11005 }
rpmSensorEnergyCLEAR NOTIFICATION-TYPE
OBJECTS { rpmSensorEnergy }
STATUS current
DESCRIPTION "RPM Sensor Accumulated Energy Clear Trap"
::= { trapPrefix 21005 }
rpmSensorVoltageNOTIFY NOTIFICATION-TYPE
OBJECTS { rpmSensorVoltage }
STATUS current
DESCRIPTION "RPM Sensor Voltage Trap"
::= { trapPrefix 11006 }
rpmSensorVoltageCLEAR NOTIFICATION-TYPE
OBJECTS { rpmSensorVoltage }
STATUS current
DESCRIPTION "RPM Sensor Voltage Clear Trap"
::= { trapPrefix 21006 }
rpmSensorVoltageMaxNOTIFY NOTIFICATION-TYPE
OBJECTS { rpmSensorVoltageMax }
STATUS current
DESCRIPTION "RPM Sensor Voltage (Max) Trap"
::= { trapPrefix 11007 }
rpmSensorVoltageMaxCLEAR NOTIFICATION-TYPE
OBJECTS { rpmSensorVoltageMax }
STATUS current
DESCRIPTION "RPM Sensor Voltage (Max) Clear Trap"
::= { trapPrefix 21007 }
rpmSensorVoltageMinNOTIFY NOTIFICATION-TYPE
OBJECTS { rpmSensorVoltageMin }
STATUS current
DESCRIPTION "RPM Sensor Voltage (Min) Trap"
::= { trapPrefix 11008 }
rpmSensorVoltageMinCLEAR NOTIFICATION-TYPE
OBJECTS { rpmSensorVoltageMin }
STATUS current
DESCRIPTION "RPM Sensor Voltage (Min) Clear Trap"
::= { trapPrefix 21008 }
rpmSensorVoltagePeakNOTIFY NOTIFICATION-TYPE
OBJECTS { rpmSensorVoltagePeak }
STATUS current
DESCRIPTION "RPM Sensor Voltage (Peak) Trap"
::= { trapPrefix 11009 }
rpmSensorVoltagePeakCLEAR NOTIFICATION-TYPE
OBJECTS { rpmSensorVoltagePeak }
STATUS current
DESCRIPTION "RPM Sensor Voltage (Peak) Clear Trap"
::= { trapPrefix 21009 }
rpmSensorCurrentNOTIFY NOTIFICATION-TYPE
OBJECTS { rpmSensorCurrent }
STATUS current
DESCRIPTION "RPM Sensor Current Trap"
::= { trapPrefix 11010 }
rpmSensorCurrentCLEAR NOTIFICATION-TYPE
OBJECTS { rpmSensorCurrent }
STATUS current
DESCRIPTION "RPM Sensor Current Clear Trap"
::= { trapPrefix 21010 }
rpmSensorRealPowerNOTIFY NOTIFICATION-TYPE
OBJECTS { rpmSensorRealPower }
STATUS current
DESCRIPTION "RPM Sensor Real Power Trap"
::= { trapPrefix 11011 }
rpmSensorRealPowerCLEAR NOTIFICATION-TYPE
OBJECTS { rpmSensorRealPower }
STATUS current
DESCRIPTION "RPM Sensor Real Power Clear Trap"
::= { trapPrefix 21011 }
rpmSensorApparentPowerNOTIFY NOTIFICATION-TYPE
OBJECTS { rpmSensorApparentPower }
STATUS current
DESCRIPTION "RPM Sensor Apparent Power Trap"
::= { trapPrefix 11012 }
rpmSensorApparentPowerCLEAR NOTIFICATION-TYPE
OBJECTS { rpmSensorApparentPower }
STATUS current
DESCRIPTION "RPM Sensor Apparent Power Clear Trap"
::= { trapPrefix 21012 }
rpmSensorPowerFactorNOTIFY NOTIFICATION-TYPE
OBJECTS { rpmSensorPowerFactor }
STATUS current
DESCRIPTION "RPM Sensor Power Factor Trap"
::= { trapPrefix 11013 }
rpmSensorPowerFactorCLEAR NOTIFICATION-TYPE
OBJECTS { rpmSensorPowerFactor }
STATUS current
DESCRIPTION "RPM Sensor Power Factor Clear Trap"
::= { trapPrefix 21013 }
--#####a2dSensorTable#####--
a2dSensorAvailNOTIFY NOTIFICATION-TYPE
OBJECTS { a2dSensorAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap"
::= { trapPrefix 11104 }
a2dSensorAvailCLEAR NOTIFICATION-TYPE
OBJECTS { a2dSensorAvail }
STATUS current
DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap"
::= { trapPrefix 21104 }
a2dSensorValueNOTIFY NOTIFICATION-TYPE
OBJECTS { a2dSensorValue }
STATUS current
DESCRIPTION "A2D Analog Sensor Measurement Trap"
::= { trapPrefix 11105 }
a2dSensorValueCLEAR NOTIFICATION-TYPE
OBJECTS { a2dSensorValue }
STATUS current
DESCRIPTION "A2D Analog Sensor Measurement Clear Trap"
::= { trapPrefix 21105 }
END
|