summaryrefslogtreecommitdiff
path: root/MIBS/fiberhome/WRI-POWER-MIB
blob: d0169b69e60a104e19aad7257037df635160fd36 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
WRI-POWER-MIB DEFINITIONS ::= BEGIN
	IMPORTS
			MODULE-IDENTITY, OBJECT-TYPE, Counter32, Gauge32,
			Integer32, TimeTicks, Counter64,enterprises,
			NOTIFICATION-TYPE,Unsigned32                    
							FROM SNMPv2-SMI       
			TEXTUAL-CONVENTION
							FROM SNMPv2-TC
			wri,wriProducts			
							FROM WRI-SMI;
	
	-- power monitor
	msppPower			MODULE-IDENTITY
        LAST-UPDATED    "201001110000Z"
        ORGANIZATION    "Wuhan FiberHome Networks Co.,Ltd."
        CONTACT-INFO
                "  FHN Customer Service
                   Tel: 027-87693784"
        DESCRIPTION
                "The MIB module to describe the monitor for power."
        REVISION        "201001110000Z" 
        DESCRIPTION
                "Add some attributes for power table"
        REVISION        "200901110000Z" 
        DESCRIPTION
                "Init version for power monitor."
        ::=   {msppChassis 2}

	
	mspp         	OBJECT IDENTIFIER ::= { wriProducts 8012 }
	msppChassis		OBJECT IDENTIFIER ::=   {mspp 1}
	

	-- mspp power table
		
--		msppPower			OBJECT IDENTIFIER ::=   {msppChassis 2}
		
		powerTable OBJECT-TYPE
			SYNTAX  SEQUENCE OF PowerEntry
			MAX-ACCESS   not-accessible
			STATUS  current
			DESCRIPTION
			         "Power information table."
			::= { msppPower 1 }

		powerEntry OBJECT-TYPE
			SYNTAX PowerEntry
			MAX-ACCESS   not-accessible
			STATUS  current
			DESCRIPTION
		         	"An entry in the power table."
			INDEX {powerIndex }
			::= { powerTable 1 }
		
		PowerEntry ::=
		    SEQUENCE {
		    powerIndex          		Unsigned32,
		    powerType           		INTEGER,
		    powerState          		INTEGER,
		    powerValue          		INTEGER,
		    powerRole	          		INTEGER,
		    powerDescr					OCTET STRING,
		    powerSerial					OCTET STRING,
		    powerTemperature			INTEGER,
			powerFuseStatus 			INTEGER,		
			powerStateBits				INTEGER, 
			powerTrapEna				INTEGER, 			
			powerAllSetting				OCTET STRING,
			--xf add 2014-7-2
			powerIndexDescr				OCTET STRING
			}
		-- The following section describes the components of the table.

			powerIndex OBJECT-TYPE
				SYNTAX  Unsigned32
				MAX-ACCESS  read-only
				STATUS  current
				DESCRIPTION
						"power index."
				::= { powerEntry 1 }

			powerType OBJECT-TYPE
				SYNTAX  INTEGER{
					dcdc(0),
					acdc(1)
				}
				MAX-ACCESS  read-only
				STATUS  current
				DESCRIPTION
						"power type, 0:DC/DC,1:AC/DC."
				::= { powerEntry 2 }
				
			powerState OBJECT-TYPE
				SYNTAX  INTEGER{
					normal(0),
				 	voltagelack(1),
					voltageoverload(2)
		    	}				
				MAX-ACCESS  read-only
				STATUS  current
				DESCRIPTION
						"power state, 0:normal,1:voltage lack,2:voltage overload."
				::= { powerEntry 3 }
				
			powerValue OBJECT-TYPE
				SYNTAX  INTEGER
				MAX-ACCESS  read-only
				STATUS  current
				DESCRIPTION
						"power value."
				::= { powerEntry 4 }
				
				
			powerRole OBJECT-TYPE
				SYNTAX  INTEGER
				MAX-ACCESS  read-write
				STATUS  current
				DESCRIPTION
						"power role."
				::= { powerEntry 5 }
				
			powerDescr OBJECT-TYPE
				SYNTAX  OCTET STRING
				MAX-ACCESS  read-write
				STATUS  current
				DESCRIPTION
						"power description."
				::= { powerEntry 6 }
				
			powerSerial OBJECT-TYPE
				SYNTAX  OCTET STRING
				MAX-ACCESS  read-only
				STATUS  current
				DESCRIPTION
						"power serial."
				::= { powerEntry 7 }
			
			powerTemperature OBJECT-TYPE
				SYNTAX  INTEGER
				MAX-ACCESS  read-only
				STATUS  current
				DESCRIPTION
						"power temperature."
				::= { powerEntry 8 }
			
			powerFuseStatus OBJECT-TYPE
				SYNTAX  INTEGER
				MAX-ACCESS  read-only
				STATUS  current
				DESCRIPTION
						"power fuse status."
				::= { powerEntry 9 }	
				
			powerStateBits OBJECT-TYPE
				SYNTAX  INTEGER {
					normal(0),
				 	voltagelack(1),
					voltageoverload(2)
		    	}
				MAX-ACCESS  read-only
				STATUS  current
				DESCRIPTION
						"bits description for power states, redundance of powerState."
				::= { powerEntry 10 }	
				
			powerTrapEna OBJECT-TYPE
				SYNTAX  INTEGER{
					enable(1),
					disable(2)
				}
				MAX-ACCESS  read-write
				STATUS  current
				DESCRIPTION
						"Enable power trap or not."
				::= { powerEntry 11 }    				
			
			powerAllSetting OBJECT-TYPE
				SYNTAX  OCTET STRING
				MAX-ACCESS  read-write
				STATUS  current
				DESCRIPTION
						"All oid operation of this table."
				::= { powerEntry 12 }		
				
			powerIndexDescr	OBJECT-TYPE
				SYNTAX  OCTET STRING
				MAX-ACCESS  read-only
				STATUS  current
				DESCRIPTION
						"Power index descrption."
				::= { powerEntry 13 }	
				
				
		powerTrap			OBJECT IDENTIFIER ::=   {msppPower 2}

		powerUp NOTIFICATION-TYPE
       		OBJECTS {powerState}
       		STATUS  current
       		DESCRIPTION
               	"power up trap."
			::= { powerTrap 1}
		
		
		powerDown NOTIFICATION-TYPE
	       	OBJECTS {powerState}
       		STATUS  current
       		DESCRIPTION
               	"power down trap."
			::= { powerTrap 2}
		
		powerFault NOTIFICATION-TYPE
	       	OBJECTS {powerState}
       		STATUS  current
       		DESCRIPTION
               	"power abnoraml trap."
			::= { powerTrap 3}
		
		powerOk NOTIFICATION-TYPE
	       	OBJECTS {powerState}
       		STATUS  current
       		DESCRIPTION
               	"power ok trap."
			::= { powerTrap 4}		


		powerGeneral			OBJECT IDENTIFIER ::=   {msppPower 3}
		powerBits OBJECT-TYPE
				SYNTAX  Counter32
				MAX-ACCESS  read-only
				STATUS  current
				DESCRIPTION
						"Bitsmap for all power being on."
				::= { powerGeneral 1 }
		powerNum OBJECT-TYPE
				SYNTAX  INTEGER
				MAX-ACCESS  read-only
				STATUS  current
				DESCRIPTION
						"power numbers."
				::= { powerGeneral 2 }
		powerTrapEnable OBJECT-TYPE
				SYNTAX  INTEGER{
					enable(1),
					disable(2)
				}
				MAX-ACCESS  read-write
				STATUS  current
				DESCRIPTION
						"Enable fan trap or not."
				::= { powerGeneral 3 }
		powerMonitorEnable OBJECT-TYPE
				SYNTAX  INTEGER{
					enable(1),
					disable(2)
				}
				MAX-ACCESS  read-write
				STATUS  current
				DESCRIPTION
						"Enable power monitor or not."
				::= { powerGeneral 4 }

END