summaryrefslogtreecommitdiff
path: root/MIBS/enterasys/CTTRAPLOG-MIB
blob: 7a80d4de7f77200f2b01e6faea76aa8e1e42a065 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
CTTRAPLOG-MIB  DEFINITIONS ::= BEGIN

--  cttraplog-mib.txt
--  Revision: 01.00.02
--  Part Number:
--  Date: July 17, 1998

--  Cabletron Systems, Inc.
--  35 Industrial Way, P.O. Box 5005
--  Rochester, NH 03867-0505
--  (603) 332-9400
--  support@ctron.com

--  This module provides authoritative definitions for Cabletron's
--  enterprise-specific trap log mib.
--
--  This module will be extended, as required.
--

--  Cabletron Systems reserves the right to make changes in
--  specification and other information contained in this document
--  without prior notice.  The reader should consult Cabletron Systems
--  to determine whether any such changes have been made.
--
--  In no event shall Cabletron Systems be liable for any incidental,
--  indirect, special, or consequential damages whatsoever (including
--  but not limited to lost profits) arising out of or related to this
--  document or the information contained in it, even if Cabletron
--  Systems has been advised of, known, or should have known, the
--  possibility of such damages.
--
--  Cabletron grants vendors, end-users, and other interested parties
--  a non-exclusive license to use this Specification in connection
--  with the management of Cabletron products.

--  Copyright July 1998 Cabletron Systems

--  PLEASE NOTE: All groups in this mib are optional

        IMPORTS 
                DisplayString
                        FROM RFC1213-MIB
                Counter, TimeTicks
                        FROM RFC1155-SMI
                OBJECT-TYPE
                        FROM RFC-1212 
                ctTrapLog
                        FROM CTRON-MIB-NAMES;

        totalNumberOfEntries  OBJECT-TYPE 
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "Total number of logged entries for this chassis."
            ::= { ctTrapLog 1 }

        configTable  OBJECT-TYPE 
            SYNTAX  SEQUENCE OF ConfigTableEntry
            ACCESS  not-accessible
            STATUS  mandatory
            ::= { ctTrapLog 2 }

        configTableEntry  OBJECT-TYPE 
            SYNTAX  ConfigTableEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION  
                    "Each entry allows a user to configure the alarm table
                    for a specific slot. Objects such as Current Entry,
                    MaxEntries Allowed, and an Enable/Disable switch are
                    available."
            INDEX   { slotInChassis }
            ::= { configTable 1 }

        ConfigTableEntry ::=
            SEQUENCE { 
                slotInChassis
                    INTEGER,
                numEntriesLoggeds
                    Counter,
                numEntriesRequested
                    INTEGER,
                numEntriesAllocated
                    INTEGER,
                lastLoggedEntryLogId
                    INTEGER,
                logCommand
                    INTEGER,
                wrap
                    INTEGER
            }

        slotInChassis  OBJECT-TYPE 
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "Each Slot can be separately configured. This is the
                    slot number for the configuration entry. "
            ::= { configTableEntry 1 }

        numEntriesLoggeds  OBJECT-TYPE 
            SYNTAX  Counter
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This is the total number of entries looged for this
                    slot."
            ::= { configTableEntry 2 }

        numEntriesRequested  OBJECT-TYPE 
            SYNTAX  INTEGER
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION  
                    "Maximum number of entries to store before wrapping
                    the log on this slot."
            ::= { configTableEntry 3 }

        numEntriesAllocated  OBJECT-TYPE 
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This is the number of entries allocated to log alarms
                    on this slot. It will always be less than or equal
                    to the requested number of entries."
            ::= { configTableEntry 4 }

        lastLoggedEntryLogId  OBJECT-TYPE 
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This is the log id of the last entry logged for this
                    slot."
            ::= { configTableEntry 5 }

        logCommand  OBJECT-TYPE 
            SYNTAX  INTEGER {
                        clearLog (1)
                    }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION  
                    "Allows the user to send the log the commands
                    specified in the enumeration."
            ::= { configTableEntry 6 }

        wrap  OBJECT-TYPE 
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This is whether or not this configuration has
                    wrapped or not."
            ::= { configTableEntry 7 }

        trapLogTable  OBJECT-TYPE 
            SYNTAX  SEQUENCE OF TrapLogEntry
            ACCESS  not-accessible
            STATUS  mandatory
            ::= { ctTrapLog 3 }

        trapLogEntry  OBJECT-TYPE 
            SYNTAX  TrapLogEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION  
                    "Each alarm entry is generated from one of the
                    following sources; (1) a module in one of the main
                    chassis slots, (2) the EM, (3) or a power supply. "
            INDEX   { slotChassis,
                      logId }
            ::= { trapLogTable 1 }

        TrapLogEntry ::=
            SEQUENCE { 
                logId
                    INTEGER,
                nvmpId
                    INTEGER,
                trapLogAcknowledged
                    INTEGER,
                trapLogVarBind
                    OCTET STRING,
                trapLogDescription
                    DisplayString,
                timeLogged
                    TimeTicks,
                filterId
                    INTEGER,
               slotChassis
                    INTEGER,
               trapOID
                    OBJECT IDENTIFIER,
                z80Time
                    TimeTicks
            }

        logId  OBJECT-TYPE 
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "Each slot has a maximium number of log entries that it
                    can support. Each entry is assigned a monotonically
                    increasing sequence number. When the maximum number
                    of entries for a slot is reached, the log wraps. Each
                    new entry will replace the oldest entry for that slot."
            ::= { trapLogEntry 1 }

        nvmpId  OBJECT-TYPE 
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This contains the nvmp id of the trap that occurred."
            ::= { trapLogEntry 2 }

        trapLogAcknowledged  OBJECT-TYPE 
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This field is set to 2 if a trap as been acknowledged
                    from the EM."
            ::= { trapLogEntry 3 }

        trapLogVarBind  OBJECT-TYPE 
            SYNTAX  OCTET STRING (SIZE (0..1500))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This is an ASN.1 encoded string representing the pairs
                    of OID/value items supplied in the original SNMP or
                    NVMP trap. "
            ::= { trapLogEntry 4 }

        trapLogDescription  OBJECT-TYPE 
            SYNTAX  DisplayString (SIZE (0..80))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This is an internally defined string used to describe
                    an alarm. Its primary use is for display on the EMs
                    LCD. A default value will be used for the old trap
                    calls."
            ::= { trapLogEntry 5 }

        timeLogged  OBJECT-TYPE 
            SYNTAX  TimeTicks
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "The time the entry was logged. This will be date and
                    time if possible."
            ::= { trapLogEntry 6 }

        filterId  OBJECT-TYPE 
            SYNTAX  INTEGER {
                        informational (1),
                        warning (2),
                        severe (3),
                        fatal (4),
                        existing (5)
                    }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This will be used to filter certain alarms. The
                    criteria is TBD. An example of classification:
                    informational - requires no intervention. warning -
                    Does not require immediate intervention. e.g. static
                    risk severe - Requires immediate intervention. e.g.
                    power overload. fatal - Requires attention and
                    module may take corrective action such as reboot. e.g.
                    Unrecoverable software or hardware error. "
            ::= { trapLogEntry 7 }

        slotChassis  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                    "Slot of this trap log."
            ::= { trapLogEntry 8 }

        trapOID  OBJECT-TYPE 
            SYNTAX  OBJECT IDENTIFIER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This OID combines the General Trap code, Specific
                    Trap code, and the sys object id into one OID."
            ::= { trapLogEntry 9 }

        z80Time  OBJECT-TYPE 
            SYNTAX  TimeTicks
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This is the time that the Z80 has been up for the 
                    board that sent this trap."
            ::= { trapLogEntry 10 }

        filterTable  OBJECT-TYPE 
            SYNTAX  SEQUENCE OF FilterEntry
            ACCESS  not-accessible
            STATUS  mandatory
            ::= { ctTrapLog 4 }

        filterEntry  OBJECT-TYPE 
            SYNTAX  FilterEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION  
                    "Each filter entry is generated from one of the
                    following sources; (1) a module in one of the main
                    chassis slots, (2) the EM, (3) or a power supply. "
            INDEX   { filterSlotInChassis,
                      filterFilterId,
                      filterLogId }
            ::= { filterTable 1 }

        FilterEntry ::=
            SEQUENCE { 
                filterLogId
                    INTEGER,
                filterNvmpId
                    INTEGER,
                filterTrapLogAcknowledged
                    INTEGER,
                filterTrapLogVarBind
                    OCTET STRING,
                filterTrapLogDescription
                    DisplayString,
                filterTimeLogged
                    TimeTicks,
                filterFilterId
                    INTEGER,
                filterSlotInChassis
                    INTEGER,
                filterTrapOID
                    OBJECT IDENTIFIER,
                filterZ80Time
                    TimeTicks
            }

        filterLogId  OBJECT-TYPE 
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "Each slot has a maximum number of log entries that it
                    can support. Each entry is assigned a monotonically
                    increasing sequence number. When the maximum number of
                    entries for a slot is reached, the log wraps. Each new
                    entry willreplace the oldest entry for that slot."
            ::= { filterEntry 1 }

        filterNvmpId  OBJECT-TYPE 
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This contains the nvmp id of the trap that was 
                    generated."
            ::= { filterEntry 2 }

        filterTrapLogAcknowledged  OBJECT-TYPE 
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This field is non-zero if a trap has been acknowleged
                    from the EM."
            ::= { filterEntry 3 }

        filterTrapLogVarBind  OBJECT-TYPE 
            SYNTAX  OCTET STRING (SIZE (0..1500))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This is an ASN.1 encoded string representing the pairs
                    of OID/value items supplied in the original SNMP or
                    NVMP trap."
            ::= { filterEntry 4 }

        filterTrapLogDescription  OBJECT-TYPE 
            SYNTAX  DisplayString (SIZE (0..80))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This is an internally defined string used to
                    describe an alarm. It's primary use is for display
                    on the EMs LCD. A default value will be used for 
                    the old trap calls."
            ::= { filterEntry 5 }

        filterTimeLogged  OBJECT-TYPE 
            SYNTAX  TimeTicks
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "The time the entry was logged. This will be date
                    and time if possible."
            ::= { filterEntry 6 }

        filterFilterId  OBJECT-TYPE 
            SYNTAX  INTEGER {
                        informational (1),
                        warning (2),
                        severe (3),
                        fatal (4),
                        existing (5)
                    }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This will be used tofilter certain alarms. The
                    criteria is TBD. An example of classification:
                    informational-requires no intervention. warning - 
                    Does not require immediate intervention. e.g. 
                    statis risk severe - Requires immediate 
                    intervention. e.g. power overload. fatal - 
                    Requires attention and module may take
                    corrective action such as reboot. e.g. Unrecoverale
                    software or hardware error."
            ::= { filterEntry 7 }

        filterSlotInChassis  OBJECT-TYPE 
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "Slot of this filter entry."
            ::= { filterEntry 8 }

        filterTrapOID  OBJECT-TYPE 
            SYNTAX  OBJECT IDENTIFIER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "This OID combines the General Trap code, Specific
                    Trap code, and the sys object id into one OID."
            ::= { filterEntry 9 }

        filterZ80Time  OBJECT-TYPE 
            SYNTAX  TimeTicks
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION  
                    "The number of time ticks that have passed since
                    this boards Z80 processor has been up."
            ::= { filterEntry 10 }


       trapLoggerAgent  OBJECT-TYPE 
            SYNTAX  INTEGER {
                disabled(1),
                enabled(2),
                standby(3),
                elected(4)
                }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION  
                    "Reflects the operational status of the traplogger agent"
        ::= { ctTrapLog 5 }
        
END