summaryrefslogtreecommitdiff
path: root/MIBS/enterasys/CTRON-ENVIRONMENT-MIB
blob: aca6c915f8303434b8c0ee0dd67f38a8104e6319 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
CTRON-ENVIRONMENT-MIB DEFINITIONS ::= BEGIN

        --  ctron-env-mib.txt Environmental MIB
        --  Revision: 1.01.01
        --  Part Number:  2170995
        --  Date: August 16, 1996

        --  Cabletron Systems, Inc.
        --  35 Industrial Way, P.O. Box 5005
        --  Rochester, NH 03867-0505
        --  (603) 332-9400
        --  support@ctron.com

        --  This module provides authoritative definitions for Cabletron's
        --  enterprise-specific ct-env MIB.
        --
        --  This module will be extended, as needed.
        --

        --  Cabletron Systems reserves the right to make changes in 
        --  specification and other information contained in this document 
        --  without prior notice.  The reader should consult Cabletron Systems
        --  to determine whether any such changes have been made.
        --
        --  In no event shall Cabletron Systems be liable for any incidental, 
        --  indirect, special, or consequential damages whatsoever (including 
        --  but not limited to lost profits) arising out of or related to this
        --  document or the information contained in it, even if Cabletron
        --  Systems has been advised of, known, or should have known, the 
        --  possibility of such damages.
        --
        --  Cabletron grants vendors, end-users, and other interested parties
        --  a non-exclusive license to use this Specification in connection
        --  with the management of Cabletron products.

        --  Copyright August 95 Cabletron Systems

        IMPORTS
                ctenv   
                        FROM CTRON-MIB-NAMES
                OBJECT-TYPE
                        FROM RFC-1212;



        --===============    group definitions     ===================

        chEnv           OBJECT IDENTIFIER  ::= { ctenv 1 }
        boardEnv        OBJECT IDENTIFIER  ::= { ctenv 2 }
        psEnv           OBJECT IDENTIFIER  ::= { ctenv 3 }
        bbuEnv          OBJECT IDENTIFIER  ::= { ctenv 4 }
        
        --    chEnv group          ====================

        --  Chassis Environment Group
        --  Implementation of the Chassis Environment group is optional.
        --  It needs to be supported when an EM is present and operational
        --  in the chassis.
        --  This group covers information on the Temperature & Humidity.
        --  This group also cover the temperature control in the form of
        --  fan speed control.

        chEnvAmbientTemp  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The ambient temperature of the room in which the chassis 
                 is located. If this sensor is broken or not supported, then
                 this object will be set to zero. The value of this object
                 is the actual temperature in degrees Fahrenheit * 10."
            ::= { chEnv 1 }

        chEnvAmbientStatus  OBJECT-TYPE
            SYNTAX  INTEGER {
                        unknown(1),             --  none of the following
                        cold(2),
                        cool(3),
                        normal(4),
                        warm(5),
                        hot(6),
                        inoperative(7)
                }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "This object reflects the status of the ambient temperature
                 reading."
            ::= { chEnv 2 }

        chEnvHumidity  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The humidity value of the air flowing thru the chassis.
                 The value of this object is the actual humidity * 10."
            ::= { chEnv 3 }

        chEnvHumidityStatus  OBJECT-TYPE
            SYNTAX  INTEGER {
                        unknown(1),             --  none of the following
                        dry(2),
                        normal(3),
                        moist(4),
                        inoperative(5)
                }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "This object reflects the status of the ambient humidity
                 reading."
            ::= { chEnv 4 }

        chEnvAmbientHot  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above which the ambient temperature
                 is deemed to be hot."
            ::= { chEnv 5 }

        chEnvAmbientWarm  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above which the ambient temperature
                 is deemed to be warm, if it is below or equal the hot 
                 value."
            ::= { chEnv 6 }

        chEnvAmbientCool  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value below which the ambient temperature
                 is deemed to be cool, if it is above or equal the cold
                 value."
            ::= { chEnv 7 }

        chEnvAmbientCold  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value below which the ambient temperature
                 is deemed to be cold."
            ::= { chEnv 8 }

        chEnvHumidityMoist  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The humidity value above which the chassis humidity
                 is deemed to be moist."
            ::= { chEnv 9 }

        chEnvHumidityDry  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The humidity value below which the chassis humidity
                 is deemed to be a static risk."
            ::= { chEnv 10 }

        chEnvNumFans  OBJECT-TYPE
            SYNTAX  INTEGER (0..64)
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "Number of fans in a chassis."
            ::= { chEnv 11 }

        chEnvFanTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF ChEnvFanEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A list of fans installed in this chassis."
            ::= { chEnv 12 }

        chEnvFanEntry  OBJECT-TYPE
            SYNTAX  ChEnvFanEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A slot entry containing objects for a particular
                 module."
            INDEX  { chEnvFanID }
            ::= { chEnvFanTable 1 }

        ChEnvFanEntry  ::=
            SEQUENCE {
                chEnvFanID
                    INTEGER,
                chEnvFanStatus
                    INTEGER,
                chEnvFanAdmin
                    INTEGER,
                chEnvFanSpeed
                    INTEGER
            }

        chEnvFanID  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "A unique value, in the range between 1 and and the 
                 value of chEnvNumFans."
            ::= { chEnvFanEntry 1 }

        chEnvFanStatus  OBJECT-TYPE
            SYNTAX  INTEGER {
                        unknown(1),             --  none of the following
                        normal(2),
                        testing(3),
                        slow(4),                -- Not running a correct speed
                        inoperative(5),
                        off(6)
                }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "This object reflects the status of the chassis fan."
            ::= { chEnvFanEntry 2 }

        chEnvFanAdmin  OBJECT-TYPE
            SYNTAX  INTEGER {
                        autoMode(1),
                        fullSpeed(2),
                        testingMode(3)
                }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "This object is used to select the operational mode of the 
                 fan. If the value is set to 1 (auto) then fan speed is 
                 based on temperature. If the value is set to 3 (testing) 
                 then value will return to it's previous value prior to 
                 being set at 3."
            DEFVAL { autoMode }
            ::= { chEnvFanEntry 3 }

        chEnvFanSpeed  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The fan speed expressed as a percentage of the maximum 
                 fan speed."
            ::= { chEnvFanEntry 4 }

        --==============    BoardEnv group          ===================

        --  Board Environment Group
        --  This group covers information on the Temperature.
        --  This group also cover the temperature control in the form of
        --  module shutdwon control.

        boardEnvSlotTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF BoardEnvSlotEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A list of networking modules installed in this chassis."
            ::= { boardEnv 1 }

        boardEnvSlotEntry  OBJECT-TYPE
            SYNTAX  BoardEnvSlotEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A slot entry containing objects for a particular
                 module."
            INDEX  { boardEnvSlotID }
            ::= { boardEnvSlotTable 1 }

        BoardEnvSlotEntry  ::=
            SEQUENCE {
                boardEnvSlotID
                    INTEGER,
                boardEnvTemp
                    INTEGER,
                boardEnvTempStatus
                    INTEGER,
                boardEnvTempRelStatus
                    INTEGER,
                boardEnvShutdownAdmin
                    INTEGER,
                boardEnvTempHot
                    INTEGER,
                boardEnvTempWarm
                    INTEGER,
                boardEnvTempCool
                    INTEGER,
                boardEnvTempCold
                    INTEGER,
                boardEnvTempRelHot
                    INTEGER,
                boardEnvTempRelWarm
                    INTEGER,
                boardEnvTempMaxFanRelHot
                    INTEGER,
                boardEnvTempMaxFanRelWarm
                    INTEGER
            }

        boardEnvSlotID  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The slot number of a chassis slot in which this board is
                 installed.  This object is similiar to chSlotID in the
                 Chassis MIB."
            ::= { boardEnvSlotEntry 1 }

        boardEnvTemp  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature of the networking board. If this sensor is 
                 broken or not supported, then this object will be set to 
                 zero. The temperature is in degrees Fahrenheit * 10."
            ::= { boardEnvSlotEntry 2 }

        boardEnvTempStatus  OBJECT-TYPE
            SYNTAX  INTEGER {
                        unknown(1),             --  none of the following
                        cold(2),
                        cool(3),
                        normal(4),
                        warm(5),
                        hot(6),
                        inoperative(7)
                }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "This object reflects the status of the board temperature
                 reading."
            ::= { boardEnvSlotEntry 3 }

        boardEnvTempRelStatus  OBJECT-TYPE
            SYNTAX  INTEGER {
                        unknown(1),             --  none of the following
                        normal(2),
                        warm(3),
                        hot(4),
                        inoperative(5)
                }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "This object reflects the status of the board temperature
                 reading relative to the ambient temperature."
            ::= { boardEnvSlotEntry 4 }

        boardEnvShutdownAdmin  OBJECT-TYPE
            SYNTAX  INTEGER {
                        enabled(1),
                        disabled(2)
                }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "This object enables or disables the auto shutdown due
                 to a temperature condition."
            DEFVAL { disabled }
            ::= { boardEnvSlotEntry 5 }

        boardEnvTempHot  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above which the board temperature
                 is deemed to be hot."
            ::= { boardEnvSlotEntry 6 }

        boardEnvTempWarm  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above which the board temperature
                 is deemed to be warm, if it is below or equal the hot 
                 value."
            ::= { boardEnvSlotEntry 7 }

        boardEnvTempCool  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value below which the board temperature
                 is deemed to be cool, if it is above or equal the cold
                 value."
            ::= { boardEnvSlotEntry 8 }

        boardEnvTempCold  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value below which the board temperature
                 is deemed to be cold."
            ::= { boardEnvSlotEntry 9 }

        boardEnvTempRelHot  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above ambient at which the board
                 temperature is deemed to be hot relative to ambient."
            ::= { boardEnvSlotEntry 10 }

        boardEnvTempRelWarm  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above ambient at which the board 
                 temperature is deemed to be warm relative to ambient, if
                 it is below the relative hot value of boardEnvTempRelHot."
            ::= { boardEnvSlotEntry 11 }

        boardEnvTempMaxFanRelHot  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above ambient at which the board
                 temperature is deemed to be hot relative to ambient, with
                 all fans in the chassis running at there maximum speed."
            ::= { boardEnvSlotEntry 12 }

        boardEnvTempMaxFanRelWarm  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above ambient at which the board 
                 temperature is deemed to be warm relative to ambient, if
                 it is below the relative hot value of boardEnvTempMaxFanRelHot,
                 with all fans in the chassis running at there maximum speed."
            ::= { boardEnvSlotEntry 13 }

        --===============    psEnv group          ====================

        --  Power Supply Environment Group
        --  This group covers information on the Temperature .
        --  This group also cover the temperature control in the form of
        --  power supply fan control.

        psEnvSlotTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF PsEnvSlotEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A list of networking modules installed in this chassis."
            ::= { psEnv 1 }

        psEnvSlotEntry  OBJECT-TYPE
            SYNTAX  PsEnvSlotEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A slot entry containing objects for a particular
                 module."
            INDEX  { psEnvSlotID }
            ::= { psEnvSlotTable 1 }

        PsEnvSlotEntry  ::=
            SEQUENCE {
                psEnvSlotID
                    INTEGER,
                psEnvTemp
                    INTEGER,
                psEnvTempStatus
                    INTEGER,
                psEnvTempHot
                    INTEGER,
                psEnvTempWarm
                    INTEGER,
                psEnvTempCool
                    INTEGER,
                psEnvTempCold
                    INTEGER,
                psEnvFanStatus
                    INTEGER,
                psEnvFanAdmin
                    INTEGER,
                psEnvFanSpeed
                    INTEGER
            }

        psEnvSlotID  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The slot number of a chassis slot in which this power supply
                 is installed.  An unique value, in the range between 1 and 
                 and the value of chNumSlots.  This object is similiar to
                 chSlotID in the Chassis MIB."
            ::= { psEnvSlotEntry 1 }

        psEnvTemp  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature of the power supply. If this sensor is 
                 broken or not supported, then this object will be set to 
                 zero. The temperature is in degrees Fahrenheit * 10."
            ::= { psEnvSlotEntry 2 }

        psEnvTempStatus  OBJECT-TYPE
            SYNTAX  INTEGER {
                        unknown(1),             --  none of the following
                        cold(2),
                        cool(3),
                        normal(4),
                        warm(5),
                        hot(6),
                        inoperative(7)
                }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "This object reflects the status of the power supply
                 temperature reading."
            ::= { psEnvSlotEntry 3 }

        psEnvTempHot  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above which the power supply
                 temperature is deemed to be hot."
            ::= { psEnvSlotEntry 4 }

        psEnvTempWarm  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above which the power supply 
                 temperature is deemed to be warm, if it is below or
                 equal the hot value."
            ::= { psEnvSlotEntry 5 }

        psEnvTempCool  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value below which the power supply 
                 temperature is deemed to be cool, if it is above or 
                 equal the cold value."
            ::= { psEnvSlotEntry 6 }

        psEnvTempCold  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value below which the power supply
                 temperature is deemed to be cold."
            ::= { psEnvSlotEntry 7 }

        psEnvFanStatus  OBJECT-TYPE
            SYNTAX  INTEGER {
                        unknown(1),             --  none of the following
                        normal(2),
                        testing(3),
                        slow(4),                -- not running a set speed
                        inoperative(5),
                        off(6)
                }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "This object reflects the status of the chassis fan."
            ::= { psEnvSlotEntry 8 }

        psEnvFanAdmin  OBJECT-TYPE
            SYNTAX  INTEGER {
                        autoMode(1),
                        fullSpeed(2),
                        testingMode(3)
                }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "This object is used to select the operational mode of the 
                 fan. If the value is set to 1 (auto) then fan speed is 
                 based on temperature. If the value is set to 3 (testing) 
                 then value will return to it's previous value prior to 
                 being set at 3."
            DEFVAL { autoMode }
            ::= { psEnvSlotEntry 9 }

        psEnvFanSpeed  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The fan speed expressed as a percentage of the maximum 
                 fan speed."
            ::= { psEnvSlotEntry 10 }

        --===============    bbuEnv group          ====================

        --  Battery Backup Unit Environment Group
        --  This group covers information on the temperature.
        --  This group also cover the temperature control in the form of
        --  fan speed control.

END