summaryrefslogtreecommitdiff
path: root/MIBS/enterasys/CT-HSIMPHYS-MIB
blob: b24ba41116b1873b15570496c82ecd8e13d8c147 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
CT-HSIMPHYS-MIB DEFINITIONS ::= BEGIN

   --  ct-hsimphys-mib.txt
   --  Revision: 01.00.00
   --  Part Number:
   --  Date: July 21, 1998

   --  Cabletron Systems, Inc.
   --  35 Industrial Way, P.O. Box 5005
   --  Rochester, NH 03867-0505
   --  (603) 332-9400
   --  support@ctron.com

   --  This module provides an enterprise-specific HSIM container MIB.
   --
   --  This module will be extended, as needed.
   --

   --  Cabletron Systems reserves the right to make changes in
   --  specification and other information contained in this document
   --  without prior notice.  The reader should consult Cabletron Systems
   --  to determine whether any such changes have been made.
   --
   --  In no event shall Cabletron Systems be liable for any incidental,
   --  indirect, special, or consequential damages whatsoever (including
   --  but not limited to lost profits) arising out of or related to this
   --  document or the information contained in it, even if Cabletron
   --  Systems has been advised of, known, or should have known, the
   --  possibility of such damages.
   --
   --  Cabletron grants vendors, end-users, and other interested parties
   --  a non-exclusive license to use this Specification in connection
   --  with the management of Cabletron products.

   --  Copyright March 98 Cabletron Systems

   --  This MIB is intended to provide a central repository & link to all
   --  information about the physical aspect of an HSIM.  Physical info
   --  includes items related to the HW inventory , BOOT, EPLD, and other
   --  low level information.  For the purposes of this MIB, no difference
   --  is recognized between a permantly-installed "option card", such as
   --  the onboard WAN interface on the HSIM-W65/75, and an actual WPIM.

   IMPORTS
      OBJECT-TYPE
         FROM RFC-1212
      DisplayString
         FROM RFC1213-MIB
      ctHSIMPhysMib
         FROM CTRON-MIB-NAMES;


   --================= HSIM Info ===================

   hsimInfo  OBJECT IDENTIFIER ::= { ctHSIMPhysMib 1 }

   hsimBoardRev  OBJECT-TYPE
         SYNTAX  DisplayString
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is the printed circuit board
         revision level."
      ::= { hsimInfo 1 }

   hsimBoardId  OBJECT-TYPE
         SYNTAX  DisplayString
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is the printed circuit board
         idenitifer."
      ::= { hsimInfo 2 }

   hsimEpldRev  OBJECT-TYPE
         SYNTAX  DisplayString
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is the programmable
         logic device revision level."
      ::= { hsimInfo 3 }

   hsimEpldId  OBJECT-TYPE
         SYNTAX  DisplayString
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is the programmable
         logic device identifier."
      ::= { hsimInfo 4 }

   hsimFsbRev  OBJECT-TYPE
         SYNTAX  DisplayString
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is the first stage
         boot revision level."
      ::= { hsimInfo 5 }

   hsimSsbRev  OBJECT-TYPE
         SYNTAX  DisplayString
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is the second stage
         boot revision level."
      ::= { hsimInfo 6 }

   hsimFwRev  OBJECT-TYPE
         SYNTAX  DisplayString
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is the HSIM firmware
         revision level."
      ::= { hsimInfo 7 }

   --=================== HSIM Peripheral MBus Info =====================

   hsimPeripheralMBusInfo OBJECT IDENTIFIER
      ::= { hsimInfo 8 }

   mBusNumberBoardsInstalled  OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is number of MBus boards
         installed in this unit."
      ::= { hsimPeripheralMBusInfo 1 }

   mBusBoardTable  OBJECT-TYPE
         SYNTAX  SEQUENCE OF MBusBoardEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
        "A list of MBus boards present in this unit"
      ::= { hsimPeripheralMBusInfo 2 }

   mBusBoardEntry  OBJECT-TYPE
         SYNTAX  MBusBoardEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is an MBus board that is
         present in this unit"
         INDEX   { mBusBoardID }
      ::= { mBusBoardTable 1 }

   MBusBoardEntry  ::=
         SEQUENCE {
                  mBusBoardID          INTEGER,
                  mBusBoardEntryType   INTEGER,
                  mBusBoardOIDPointer  OBJECT IDENTIFIER
                  }

   mBusBoardID OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is an index that uniquely
         identifies the physical MBus board within the system."
      ::= { mBusBoardEntry 1 }

   mBusBoardEntryType OBJECT-TYPE
         SYNTAX  INTEGER   {
                           unknown(1),
                           cmm(2)
                           }

         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object identifies the type of MBus
         board installed."
      ::= { mBusBoardEntry 2 }

   mBusBoardOIDPointer OBJECT-TYPE
         SYNTAX  OBJECT IDENTIFIER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object defines the start of a MIB that
         can be used to determine more specific information about
         the given MBus board."
      ::= { mBusBoardEntry 3 }


   --=================== HSIM Peripheral WPIM Info =====================

   hsimPeripheralWpimInfo OBJECT IDENTIFIER
      ::= { hsimInfo 9 }

   wpimNumberBoardsInstalled  OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is number of WPIM boards
         installed in this unit."
      ::= { hsimPeripheralWpimInfo 1 }

   wpimBoardTable  OBJECT-TYPE
         SYNTAX  SEQUENCE OF WpimBoardEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
        "A list of WPIM boards present in this unit"
      ::= { hsimPeripheralWpimInfo 2 }

   wpimBoardEntry  OBJECT-TYPE
         SYNTAX  WpimBoardEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is a WPIM board that is
         present in this unit"
         INDEX   { wpimBoardID }
      ::= { wpimBoardTable 1 }

   WpimBoardEntry  ::=
         SEQUENCE {
                  wpimBoardID          INTEGER,
                  wpimBoardEntryType   OBJECT IDENTIFIER,
                  wpimBoardOIDPointer  OBJECT IDENTIFIER
                  }

   wpimBoardID OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is an index that uniquely
         identifies this WPIM board."
      ::= { wpimBoardEntry 1 }

   wpimBoardEntryType OBJECT-TYPE
         SYNTAX  OBJECT IDENTIFIER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object identifies the type of WPIM
         board installed.  This is within the portWpim branch
         of the namingTree (1.3.6.1.4.1.52.3.8.1.2.5)"
      ::= { wpimBoardEntry 2 }

   wpimBoardOIDPointer OBJECT-TYPE
         SYNTAX  OBJECT IDENTIFIER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object defines the start of a MIB that
         can be used to determine more specific information about
         the given WPIM board."
      ::= { wpimBoardEntry 3 }

   --=================== HSIM Local HW Devices Info =====================

   hsimLocalHwDevicesInfo OBJECT IDENTIFIER
      ::= { hsimInfo 10 }

   localHwDevicesTable  OBJECT-TYPE
         SYNTAX  SEQUENCE OF LocalHwDevicesEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
        "A list of specific hardware devices present in this unit"
      ::= { hsimLocalHwDevicesInfo 1 }

   localHwDevicesEntry  OBJECT-TYPE
         SYNTAX  LocalHwDevicesEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is a WPIM module that is
         present in this unit"
         INDEX   { localHwDeviceID }
      ::= { localHwDevicesTable 1 }

   LocalHwDevicesEntry  ::=
         SEQUENCE {
                  localHwDeviceID            INTEGER,
                  localHwDeviceType          INTEGER,
                  localHwDeviceOperStatus    INTEGER,
                  localHwDeviceAdminStatus   INTEGER
                  }

   localHwDeviceID OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is an index that uniquely
         identifies the assoicated local hardware device."
      ::= { localHwDevicesEntry 1 }

   localHwDeviceType OBJECT-TYPE
         SYNTAX  INTEGER {
                         unknown(1),
                         siemensMunich32(2),
                         mitelMT8985(3)
                         }
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object identifies the type of local
         hardware device.  These local hardware devices are those
         specific ICs unique to this HSIM such as Siemens
         Munich32, or Mitel MT8985."
      ::= { localHwDevicesEntry 2 }

   localHwDeviceOperStatus OBJECT-TYPE
         SYNTAX  INTEGER {
                   up(1),       -- ready to pass packets
                   down(2),
                   testing(3),  -- in some test mode
                   unknown(4),  -- status can not be determined
                                -- for some reason.
                   dormant(5)
               }
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "This object describes the current state of the device."
      ::= { localHwDevicesEntry 3 }

   localHwDeviceAdminStatus OBJECT-TYPE
         SYNTAX  INTEGER {
                   up(1),       -- ready execute
                   down(2),
                   testing(3)   -- in some test mode
               }
         ACCESS  read-write
         STATUS  mandatory
         DESCRIPTION
        "This object is used by the Network Management System to
         request a change in the current state of the device."
      ::= { localHwDevicesEntry 4 }

END