1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
|
-- *****************************************************************************
-- FILE NAME : mca.mib
-- DATE : December 20, 2004
-- AUTHOR : Greg Saltis
-- PROJECT : Vortex Ethernet Card
-- PUBLIC :
-- PRIVATE :
-- COPYRIGHT : Copyright (C) 2004 by Emerson Network Power
-- ******************************************************************************
-- ******************************************************************************
-- MODIFICATION HISTORY
--
-- v1.0.0.0 09-06-04 grs New File.
-- v1.0.0.1 12-20-04 grs Add Modification history
-- Add
-- vecMCAInformation
-- vecMCAMessageRequests
-- vecMCAMessageTransmissions
-- vecMCAMessageTransmissions
-- vecMCAMessageBadCRCs
-- vecMCAMessageLinkErrors
-- vecMCAMessagePartialResponses
-- vecMCAMessageWrongPackets
-- v1.0.0.2 01-29-05 gp
-- Add
-- vecMCAMessageErrorReplies
-- Remove
-- vecAlarmLVDAlarm
-- vecAlarmPCUFailAlarm
-- vecAlarmAudibleAlarmsAreQuiet
-- vecAlarmACFail
-- vecAlarmPasswordHasBeenViewed
-- vecAlarmAudibleRelayDeEnergized
-- v1.0.0.3 07-05-05 gp
-- Add vecAnalogBatteryReserveHours
--
-- v2.0.0.3 07-12-05 gp
-- Add
-- vecAlarmBatteryPoorHealth
-- vecAlarmBatteryReserveLow
--
-- Grouped all battery related traps together.
--
-- v2.0.0.4 10-05-05 gp
-- Add versioning mechanism to MIB. Version information is
-- added to DEFINITIONS statement as follows:
-- VEC-MIBvX DEFINITIONS ::=
--
-- v3.0 10-31-05 gp
-- Add
-- vecHVSActive
-- vecRemoteHVSActive
-- vecRemoteEstopActive
--
-- v4.0 12-13-05 gp
-- Changed company name
-- Revamped to highlight power system information.
--
-- 12-15-05 gp
-- Corrected incorrect labeling for PCU Total current.
--
-- v5.0 12-16-05 gp
-- VEC no longer issues traps for the following MCA alarm conditions:
-- general LVD No Reply alarm
-- general LVD Board Fail alarm
-- general Temperature Sensor Hi or Lo alarm
-- general Temperature Sensor High alarm
-- general Temperature Sensor Low alarm
-- general Temperature Sensor No Reply alarm
-- general Shunt Type alarm
-- general Shunt No Reply alarm
--
-- v5.1 8-04-08 jws
-- Update IMPORTS
-- Added module identity
-- Removed SIZE clause
--
-- v5.4 9-22-08 jws
-- Changed trap object tables to NOTIFICATION-TYPE
--
-- v5.5 9-23-08 jws
-- Typo correction on psAlarmSysInfoString2
--
-- v5.6 10-01-08 gp
-- Corrected vecMIB OID. Replaced references to vec OID with vecMIB.
--
-- v5.7 02-11-11 gp
-- Add
-- psAlarm
-- psHighestSeverityLevel
-- psTemperatureAlarmStatus
-- psLVDCircuitAAlarmStatus
-- psLVDCircuitBAlarmStatus
-- psShuntAlarmStatus
--
--
-- v5.7 08-28-12 jws
-- Corrected Syntax error invalues of INTEGER
-- spaces removed
-- ******************************************************************************
VEC-MIBv5-9 DEFINITIONS ::=
BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32, Counter32, enterprises
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DisplayString, DateAndTime
FROM SNMPv2-TC;
vecMIB MODULE-IDENTITY
LAST-UPDATED "201401140823Z"
ORGANIZATION "
Emerson Energy Systems North America (ESNA)"
CONTACT-INFO "
Emerson Energy Systems North America
1510 Kansas Ave.
Lorain, OH 44052
USA "
DESCRIPTION "
Emerson Energy Systems North America(ESNA) VEC MIB. revision 5.9"
::= { enterprises 885 3 }
-- OBJECTS
emersonESNA OBJECT IDENTIFIER ::= { enterprises 885 }
vecInformation OBJECT IDENTIFIER ::= { vecMIB 1 }
vecMessageStats OBJECT IDENTIFIER ::= { vecInformation 2 }
psStatus OBJECT IDENTIFIER ::= { vecMIB 2 }
psMeasurement OBJECT IDENTIFIER ::= { psStatus 1 }
psTraps OBJECT IDENTIFIER ::= { vecMIB 3 }
psAlarmsGeneral1 OBJECT IDENTIFIER ::= { psTraps 1 }
psAlarmsGeneral2 OBJECT IDENTIFIER ::= { psTraps 2 }
psAlarmsBattery OBJECT IDENTIFIER ::= { psTraps 3 }
-- ENTRIES
vecFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VEC System Firmware Version."
::= { vecInformation 1}
vecMessageRequests OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of message requests."
::= { vecMessageStats 1 }
vecMessageTransmissions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of messages transmitted."
::= { vecMessageStats 2 }
vecMessageNoResponses OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of no responses."
::= { vecMessageStats 3 }
vecMessageBadCRCs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of bad CRC checks."
::= { vecMessageStats 4 }
vecMessageLinkErrors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of link errors."
::= { vecMessageStats 5 }
vecMessagePartialResponses OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of partial responses received."
::= { vecMessageStats 6 }
vecMessageWrongPackets OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of wrong packet numbers detected."
::= { vecMessageStats 7 }
vecMessageErrorReplies OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of error responses received."
::= { vecMessageStats 8 }
psSystemVoltage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System Voltage."
::= { psMeasurement 1}
psSystemCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System Current."
::= { psMeasurement 2}
psSubsystemVoltage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sub System Voltage."
::= { psMeasurement 3}
psSubsystemCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sub System Current."
::= { psMeasurement 4}
psSenseVoltage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sense Voltage."
::= { psMeasurement 5}
psPCUTotalCurrent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total PCU Current."
::= { psMeasurement 6}
psBatteryCurrent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Battery Current."
::= { psMeasurement 7}
psBatteryReserveHours OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Battery Reserve Time."
::= { psMeasurement 8}
psAlarm OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Power System Alarm Is Active."
::= { psMeasurement 9 }
psHighestSeverityLevel OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
minor(1),
major(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity level is the highest active alarm level.
Values: 0 = Normal, 1 = Minor, 2 = Major"
::= { psMeasurement 10}
psNumberOfPCUsInstalled OBJECT-TYPE
SYNTAX Integer32(0..80)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of PCUs installed"
::= { psMeasurement 11}
psNumberOfPCUsCommunicating OBJECT-TYPE
SYNTAX Integer32(0..80)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of PCUs communicating"
::= { psMeasurement 12}
psTemperatureTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSTemperatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Temperature Measurement Table."
::= { psStatus 2 }
psTemperatureEntry OBJECT-TYPE
SYNTAX PSTemperatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Temperature Measurement Table Entry."
INDEX { psTemperatureIndex }
::= { psTemperatureTable 1 }
PSTemperatureEntry ::= SEQUENCE {
psTemperatureIndex Integer32,
psTemperatureMeasurement DisplayString,
psTemperatureAlarmStatus Integer32
}
psTemperatureIndex OBJECT-TYPE
SYNTAX Integer32(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature Probe Number "
::= { psTemperatureEntry 1 }
psTemperatureMeasurement OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature Value In Centigrade."
::= { psTemperatureEntry 2 }
psTemperatureAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
high(0),
low(1),
noreply(2),
none(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature Probe Alarm Status "
::= { psTemperatureEntry 3 }
psLVDTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSLVDEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Low Voltage Disconnect Table."
::= { psStatus 3 }
psLVDEntry OBJECT-TYPE
SYNTAX PSLVDEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Low Voltage Disconnect Table Entry."
INDEX { psLVDIndex }
::= { psLVDTable 1 }
PSLVDEntry ::= SEQUENCE {
psLVDIndex Integer32,
psLVDCircuitA DisplayString,
psLVDCircuitB DisplayString,
psLVDCircuitAAlarmStatus Integer32,
psLVDCircuitBAlarmStatus Integer32
}
psLVDIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LVD Number "
::= { psLVDEntry 1 }
psLVDCircuitA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LVD Circuit A Disconnect Voltage "
::= { psLVDEntry 2 }
psLVDCircuitB OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LVD Circuit B Disconnect Voltage "
::= { psLVDEntry 3 }
psLVDCircuitAAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
disconnected(0),
noreply(1),
boardfail(2),
none(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LVD Circuit A Alarm Status "
::= { psLVDEntry 4 }
psLVDCircuitBAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
disconnected(0),
noreply(1),
boardfail(2),
none(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LVD Circuit B Alarm Status "
::= { psLVDEntry 5 }
psDistributionTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSShuntEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Shunt Pod Table"
::= { psStatus 4 }
psShuntEntry OBJECT-TYPE
SYNTAX PSShuntEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Shunt Pod Table Entry."
INDEX { psShuntIndex }
::= { psDistributionTable 1 }
PSShuntEntry ::= SEQUENCE {
psShuntIndex Integer32,
psShuntCurrent DisplayString,
psShuntAlarmStatus Integer32,
psShuntType Integer32
}
psShuntIndex OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shunt Pod Number."
::= { psShuntEntry 1 }
psShuntCurrent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shunt POD Current."
::= { psShuntEntry 2 }
psShuntAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
type(0),
noreply(1),
none(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shunt POD Alarm Status.
Values: 0 = Type, 1 = No Reply, 2 = No Alarm"
::= { psShuntEntry 3 }
psShuntType OBJECT-TYPE
SYNTAX INTEGER {
system(1),
subsystem(2),
battery(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shunt POD Alarm Status.
Values: 0 = System, 1 = Subsystem, 2 = Battery"
::= { psShuntEntry 4 }
psPCUTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSPCUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PCU Table."
::= { psStatus 5 }
psPCUEntry OBJECT-TYPE
SYNTAX PSPCUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PCU Table Entry."
INDEX { psPCUIndex }
::= { psPCUTable 1 }
PSPCUEntry ::= SEQUENCE {
psPCUIndex Integer32,
psPCUFail Integer32,
psPCUCurrent Integer32,
psPCUFerroGateway Integer32,
psPCUProductNumber DisplayString,
psPCUSWVersion DisplayString,
psPCUSerialNumber DisplayString,
psPCUCapacity DisplayString
}
psPCUIndex OBJECT-TYPE
SYNTAX Integer32(1..80)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCU Number."
::= { psPCUEntry 1 }
psPCUFail OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCU Fail Alarm"
::= { psPCUEntry 2 }
psPCUCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCU Current"
::= { psPCUEntry 3 }
psPCUFerroGateway OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCU is a Ferro Gateway Rectifier."
::= { psPCUEntry 4 }
psPCUProductNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rectifier Product Number."
::= { psPCUEntry 5}
psPCUSWVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rectifier Software Revision."
::= { psPCUEntry 6}
psPCUSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rectifier Serial Number."
::= { psPCUEntry 7}
psPCUCapacity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rectifier Rated Current"
::= { psPCUEntry 8 }
psEmergencyStop NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Emergency Stop Alarm."
::= { psAlarmsGeneral1 1 }
psAlarmVeryLowVoltage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"50 Percent Battery On Discharge Alarm."
::= { psAlarmsGeneral1 2 }
psAlarmLowVoltage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Battery On Discharge Alarm."
::= { psAlarmsGeneral1 3 }
psAlarmSystemHighVoltage1 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"High Voltage 1 Alarm."
::= { psAlarmsGeneral1 4 }
psAlarmSystemHighVoltage2 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"High Voltage 2 Alarm."
::= { psAlarmsGeneral1 5 }
psAlarmSubsystemLowVoltage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Subsystem Low Voltage Alarm."
::= { psAlarmsGeneral1 6 }
psAlarmSubsystemHighVoltage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Subsystem High Voltage Alarm."
::= { psAlarmsGeneral1 7 }
psAlarmSystemFuse NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"System Fuse Alarm."
::= { psAlarmsGeneral1 8 }
psAlarmSubsystemFuse NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Subsystem Fuse Alarm."
::= { psAlarmsGeneral1 9 }
psAlarmAllACOff NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"All AC Off Alarm."
::= { psAlarmsGeneral1 10 }
psAlarmSystemOverCurrent NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"System Over Current Alarm."
::= { psAlarmsGeneral1 11 }
psAlarmSubsystemOverCurrent NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Subsystem Over Current Alarm."
::= { psAlarmsGeneral1 12 }
psAlarmLVDsAreInhibited NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVDs Are Inhibited Alarm."
::= { psAlarmsGeneral1 13 }
psAlarmTestEqualizeMode NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Test/Equalize Mode Active."
::= { psAlarmsGeneral1 14 }
psAlarmMinor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"System Minor Alarm."
::= { psAlarmsGeneral1 15 }
psAlarmMajor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"System Major Alarm."
::= { psAlarmsGeneral1 16 }
psAlarmSenseVoltageFuse NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Sense Voltage Fuse Alarm."
::= { psAlarmsGeneral1 17 }
psAlarmSystemVoltageFuse NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"System Voltage Fuse Alarm."
::= { psAlarmsGeneral1 18 }
psAlarmNoSystemVoltage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"No System Voltage Alarm."
::= { psAlarmsGeneral1 19 }
psAlarmNoSubsystemVoltage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"No Subsystem Voltage Alarm."
::= { psAlarmsGeneral1 20 }
psAlarmNoSenseVoltage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"No Sense Voltage Alarm."
::= { psAlarmsGeneral1 21 }
psAlarmDisplayNoReply NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Display Communications Alarm."
::= { psAlarmsGeneral1 22 }
psAlarmSubsystemMajor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Subsystem Major Alarm."
::= { psAlarmsGeneral1 23 }
psAlarmSubsystemMinor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Subsystem Minor Alarm."
::= { psAlarmsGeneral1 24 }
psAlarmHighACLine NOTIFICATION-TYPE
STATUS current
DESCRIPTION
" High AC Line Alarm."
::= { psAlarmsGeneral1 25 }
psAlarmSenseVoltageError NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Sense Voltage Error Alarm."
::= { psAlarmsGeneral1 26 }
psTestEqualizeHardwareInput NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The MCA Test Equalize Hardware Input Active."
::= { psAlarmsGeneral2 1 }
psPCUFailMajor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Fail Major Alarm."
::= { psAlarmsGeneral2 2 }
psPCUFailMinor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Fail Minor Alarm."
::= { psAlarmsGeneral2 3 }
psLVDAlarmMajor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVD Major Alarm."
::= { psAlarmsGeneral2 4 }
psLVDAlarmMinor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVD Minor Alarm."
::= { psAlarmsGeneral2 5 }
psPCULoadShare NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Load Share Alarm."
::= { psAlarmsGeneral2 6 }
psACFailMajor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"AC Fail Major Alarm."
::= { psAlarmsGeneral2 7 }
psACFailMinor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"AC Fail Minor Alarm."
::= { psAlarmsGeneral2 8 }
psMCACommFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"MCA Communications Failure Alarm."
::= { psAlarmsGeneral2 9 }
psHVSActive NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"High Voltage Shutdown Active."
::= { psAlarmsGeneral2 10 }
psRemoteHVSActive NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Remote High Voltage Shutdown Active."
::= { psAlarmsGeneral2 11 }
psRemoteEstopActive NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Remote Emergency Stop Active."
::= { psAlarmsGeneral2 12 }
psAlarmBatteryChargeOverCurrent NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Battery Charge Over Current Alarm."
::= { psAlarmsBattery 1 }
psBatteryCurrentLimitInhibited NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Battery Current Limit Inhibited Alarm."
::= { psAlarmsBattery 2 }
psAlarmBatteryPoorHealth NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Battery Poor Health Alarm."
::= { psAlarmsBattery 3 }
psAlarmBatteryReserveLow NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Battery Reserve Low Alarm."
::= { psAlarmsBattery 4 }
psPCUSummaryTypeTraps OBJECT IDENTIFIER ::= { psTraps 4 }
psPCUSummaryTraps OBJECT IDENTIFIER ::= { psPCUSummaryTypeTraps 1 }
psAlarmPCUSummary NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Alarm Active."
::= { psPCUSummaryTraps 2 }
psPCUNodeTypeTraps OBJECT IDENTIFIER ::= { psTraps 5 }
psPCUTraps OBJECT IDENTIFIER ::= { psPCUNodeTypeTraps 1 }
psAlarmPCUId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCU Number."
::= { psPCUTraps 1 }
psAlarmPCUHighACLine NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU High AC Line Alarm."
::= { psPCUTraps 2 }
psAlarmPCUControllerFailure NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Controller Failure Alarm."
::= { psPCUTraps 3 }
psAlarmPCUFanSlowOrStopped NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Fan Slow Or Stopped Alarm."
::= { psPCUTraps 4 }
psAlarmPCUTurnedOffByMca NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Turned Off By MCA."
::= { psPCUTraps 5 }
psAlarmPCUCircuitBreakerOff NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Circuit Breaker Off Alarm."
::= { psPCUTraps 6 }
psAlarmPCUDCorACConvertFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Converter Fail Alarm."
::= { psPCUTraps 7 }
psAlarmPCUThermalAlarmorCurrentLimit NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Thermal Current Limit Alarm."
::= { psPCUTraps 8 }
psAlarmPCUEmergencyStop NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Emergency Stop Alarm."
::= { psPCUTraps 9 }
psAlarmPCUInputSwitchOff NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Input Switch Off Alarm."
::= { psPCUTraps 10 }
psAlarmPCUHighVoltageShutdown NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU High Voltage Shutdown Alarm."
::= { psPCUTraps 11 }
psAlarmPCUACInputIsOffOrLow NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU AC Input Is Off Or Low Alarm."
::= { psPCUTraps 12 }
psAlarmPCUCommunicationFailureWithMCA NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Communication Failure Alarm."
::= { psPCUTraps 13 }
psAlarmPCUSenseLeadOpen NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Sense Lead Open Alarm."
::= { psPCUTraps 14 }
psShuntTypeTraps OBJECT IDENTIFIER ::= { psTraps 6 }
psShuntTraps OBJECT IDENTIFIER ::= { psShuntTypeTraps 1 }
psAlarmShuntId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shunt POD Number."
::= { psShuntTraps 1 }
psAlarmShuntType NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Shunt POD Type Alarm."
::= { psShuntTraps 2 }
psAlarmShuntNoReply NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Shunt POD Communications Alarm."
::= { psShuntTraps 3 }
psLVDTypeTraps OBJECT IDENTIFIER ::= { psTraps 7 }
psLVDTraps OBJECT IDENTIFIER ::= { psLVDTypeTraps 1 }
psAlarmLVDId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Analog LVD Number "
::= { psLVDTraps 1 }
psAlarmLVDDisconnectedA NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVD Circuit A Disconnected Alarm."
::= { psLVDTraps 2 }
psAlarmLVDNoReplyA NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVD Circuit A Communications Alarm."
::= { psLVDTraps 3 }
psAlarmLVDBoardFailA NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVD Board Circuit A Fail Alarm."
::= { psLVDTraps 4 }
psAlarmLVDDisconnectedB NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVD Circuit B Disconnected Alarm."
::= { psLVDTraps 5 }
psAlarmLVDNoReplyB NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVD Circuit B No Communications Alarm."
::= { psLVDTraps 6 }
psAlarmLVDBoardFailB NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVD Board Circuit B Fail Alarm."
::= { psLVDTraps 7 }
psTemperatureTypeTraps OBJECT IDENTIFIER ::= { psTraps 8 }
psTemperatureTraps OBJECT IDENTIFIER ::= { psTemperatureTypeTraps 1 }
psAlarmTemperatureId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature Probe Number."
::= { psTemperatureTraps 1 }
psAlarmTemperatureHigh NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Temperature High Alarm."
::= { psTemperatureTraps 2 }
psAlarmTemperatureLow NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Temperature Low Alarm."
::= { psTemperatureTraps 3 }
psAlarmTemperatureNoReply NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Temperature Communications Alarm."
::= { psTemperatureTraps 4 }
psSysInfoTypeTraps OBJECT IDENTIFIER ::= { psTraps 9 }
psSysInfoTraps OBJECT IDENTIFIER ::= { psSysInfoTypeTraps 1 }
psAlarmSysInfoError1 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo Error 1."
::= { psSysInfoTraps 1 }
psAlarmSysInfoError2 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo Error 2."
::= { psSysInfoTraps 2 }
psAlarmSysInfoString1 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 1."
::= { psSysInfoTraps 3 }
psAlarmSysInfoString2 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 2."
::= { psSysInfoTraps 4 }
psAlarmSysInfoString3 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 3."
::= { psSysInfoTraps 5 }
psAlarmSysInfoString4 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 4."
::= { psSysInfoTraps 6 }
psAlarmSysInfoString5 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 5."
::= { psSysInfoTraps 7 }
psAlarmSysInfoString6 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 6."
::= { psSysInfoTraps 8 }
psAlarmSysInfoString7 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 7."
::= { psSysInfoTraps 9 }
psAlarmSysInfoString8 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 8."
::= { psSysInfoTraps 10 }
psAlarmSysInfoString9 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 9."
::= { psSysInfoTraps 11 }
psAlarmSysInfoString10 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 10."
::= { psSysInfoTraps 12 }
END
|